Desiccant Dehumidifier

Similar documents
Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. DH90 Whole House Dehumidifier

Ultra-Aire 150H Whole House Ventilating Dehumidifier

Model 1750A/ 1770A Dehumidifier Installation Instructions

INSTALLER S & OWNER S MANUAL

Installation, Operation and Maintenance Instructions

INSTALLER S & OWNER S MANUAL

Quest Dry 105, 155, and 205 Dual

Quest 105, Dry155, and 205 Dual

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Safety and Installation Instructions Model 1700

Model 1820 Dehumidifier

INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Installation, Safety & Maintenance Manual Model 1750A/1770A

Model DEHXXCDA1070 & DEHXXCDA1095 Dehumidifier Installation Instructions

INSTALLER S & OWNER S MANUAL

Owner s Manual HI-E Dry Vehere

Read and Save These Instructions

Model 1870 & 1870W Dehumidifier Installation Instructions

INSTALLER S & OWNER S MANUAL

Quest Dry Quest Dry 105, 155, and 205

INSTALLER S & OWNER S MANUAL

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

HVAC Equipment Access Equipment Location

Installation Instructions INSTALLATION BY A HVAC PROFESSIONAL IS RECOMMENDED

Installation Instructions INSTALLATION BY A HVAC PROFESSIONAL IS RECOMMENDED

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Owner s Manual Phoenix Arctic Max

Installation Instructions INSTALLATION BY A HVAC PROFESSIONAL IS RECOMMENDED

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

CENTRAL, SPLIT SYSTEM REFRIGERATED AIR-CONDITIONING INSPECTION INTERIOR

S1-CVD070T01A / S1-CVD095T01A Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION

MODEL 1830/1850/1870 DEHUMIDIFIER APPLICATION QUICK START GUIDE

PHOENIX 200 MAX. 1 Specifications. 2 Operation. Therma-Stor Products. Phoenix 200 Max Operation & Service Instructions

Installation Instructions INSTALLATION BY A HVAC PROFESSIONAL IS RECOMMENDED

Owner s Manual Ultimate 340

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

Installation & Operation Instructions

WineZone Ceiling Mount Ductless Split 15

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

Read and Save These Instructions

SMART ERV Energy Recovery Ventilator. Build It Tight / Ventilate It Right!

Installation Instructions

Quest DRY quest. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest DRY 180:

DES CHAMPS PRODUCTS 85% 4,400 CFM

Installation Instructions INSTALLATION BY A HVAC PROFESSIONAL IS RECOMMENDED

Surna Dehumidifier Operating & Maintenance Manual

READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS

Ventilation for New Low-Rise Residential Buildings July 20, 2015

Technical Datasheets. Always By Your Side.

Inspection Checklist Mechanical Rough in

SAFETY AND INSTALLATION MANUAL MODEL 8100

Installation Instructions INSTALLATION BY A HVAC PROFESSIONAL IS RECOMMENDED

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

Portable Dehumidifier with Internal Pump

Installation Instructions INSTALLATION BY A HVAC PROFESSIONAL IS RECOMMENDED

Installation & Operation Instructions

50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

Model 76 Dehumidifier Control Installation Instructions

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

INSTALLER S & OWNER S MANUAL

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

4201 Lien Rd. Madison, WI Owner s Manual Phoenix R175 LGR Dehumidifier. Installation, Operation & Service Instructions

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Heat or Energy Recovery Ventilation System

GL-DEH Series Portable Dehumidifier Operating Instructions

π H-6369, H-6370 DEHUMIDIFIER GENERAL INFORMATION uline.com WATER IN THE BUCKET RECOMMENDED HUMIDITY LEVELS WARM AIR EXHAUST IS NORMAL

4201 Lien Rd. Madison, WI Owner s Manual Phoenix R200 LGR Dehumidifier. Installation, Operation & Service Instructions

Quest 215 DryDual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

B SERIES ELECTRIC FURNACE

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

Installation Instructions

Model 8120 and 8126 Safety & Installation Instructions

4201 Lien Rd. Madison, WI Owner s Manual Phoenix R250 LGR Dehumidifier. Installation, Operation & Service Instructions

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

INSTALLATION AND OPERATION MANUAL Model BR70/BR130

Tech to Tech May 07 HRV s & ERV s

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Aprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Owner s Manual Phoenix 250 MAX

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850

Installation Instructions INSTALLATION BY A HVAC PROFESSIONAL IS RECOMMENDED

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

T-Series Air Conditioner T20 Model

Zoning System Design Manual

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

HVAC for Raters & Inspectors

USER S GUIDE. For all Packaged Systems (Air Conditioners and Heat Pumps)

Installation Instructions INSTALLATION BY A HVAC PROFESSIONAL IS RECOMMENDED

Installation Instructions

Transcription:

Since the 1950s Desiccant Dehumidifier Dry Spaces With NO Added Heat BMIL Technologies, LLC 4915 Arendell St., #313 Morehead City, NC 28557 PH 252-727-0994 FAX 252-727-0996 WWW.BMIL.COM

Product Description & Advantages The Munters DryCool HD desiccant dehumidifier provides significant drying capability in a small package. The unit utilizes a refrigerant circuit in conjunction with a heat reactivated desiccant wheel to provide efficient drying capability. Due to the capabilities of the desiccant wheel, the unit can continue to provide substantial capacity and low supply dew point conditions. The hybrid desiccant refrigeration cycle provides the most efficient small dehumidifier available. In addition, the supply air is discharged at approximately space neutral temperature so that it does not add additional cooling load to the space. The DryCool HD operates cost-effectively because all of the energy required for the operation of the desiccant dehumidifier cycle is recycled from the cooling components. Capacities & Performance Blower Blower Efficiency 250 CFM @ 0.4 250 ESCFM P @ 0.4 3.3 ESLiters P per KW Capacity Capacity 5 lbs/hr @ 80ºF, NO 60% Heat RH Load 5 lbs/hr @ 80 F, 60% Efficiency RH to A/C System 3.3 Liters per KW Electrical (Typical Electrical Operating Amperage) (Typical Operating Amperage) 6.8 6.7 amps amps @120 @120 volt volt / 60H 60HZ Z

Performance Psychrometric Advantage

Since the 1950s Airflow Illustration INLET FROM TREATED SPACE (Return Air Duct) SUPPLY OUTLET TO TREATED SPACE EVAPORATION COIL REACTIVATION AIR INTAKE FROM OUTDOORS CONDENSER COIL DESICCANT WHEEL REACTIVATION AIR EXHAUST DUCTED OUTDOORS

How it Works The DryCool HD uses a refrigeration system similar to an air conditioner to remove heat and moisture from the incoming air. A desiccant wheel downstream of the evaporator coil removes additional water from the air stream in the vapor state. The DryCool HD dehumidifier uses two air streams to accomplish this task of providing cool dry air at high efficiencies. The supply air stream sends cool dry air to the space while the reactivation air stream removes the water collected by the wheel and sends it to the outside. Benefits Affordable dehumidification Uses environmentally friendly refrigerant R-410a Compact size for installations in small spaces Prevents mold and mildew Total indoor air quality options available

Desiccant Dehumidifier OPERATING MANUAL GENERAL WARNINGS & CAUTIONS All electrical work should only be performed by qualified electrical personnel. Repair to electrical components by non-certified technician may result in personal injury and/or damage to the unit. Installation should be conducted by a qualified technician only. Munters and Munters affiliate are not responsible for injuries and /or damages caused by improper installation. 1 Installation 1.1 Ducting for Dehumidification The DRYCOOL HD Dehumidifier uses a unique arrangement of two air streams to accomplish the task of providing cool dry air at high efficiencies. These are a supply air stream and a reactivation air stream. The supply air stream is meant to dehumidify air for the space being controlled. The reactivation air stream expels the water vapor collected by the desiccant dehumidification wheel. CAUTION MAKE SURE THE UNIT IS LEVEL. Supply Air Duct A 16 W x 14 " H inlet located on the same side as an 8 round outlet supply air connection for the unit. The inlet can be connected directly to the return air duct coming from the central part of the structure. This duct could draw air from the central part of the structure and supply it to the isolated areas of the structure like smaller rooms. The ductwork of the existing heating system can be used to supply air to the structure. If the existing supply goes to isolated areas of the structure, discharge the supply of the DRYCOOL HD unit into the supply of the existing central system. DO NOT draw air directly from the kitchen or laundry. The supply outlet of the DRYCOOL HD is located on the same side as the return inlet. A length of 6 feet or more of flex duct on the outlet of the unit will reduce air noise from the blower. A length of flexible duct on all DRYCOOL HD duct connections is recommended to reduce noise and

vibration transmitted to rigid ductwork in the structure. Ducting the DRYCOOL HD as mentioned in section 1.1 requires consideration of the following points: Duct Sizing: For total duct lengths up to 25', use a minimum 8" diameter round or equivalent rectangular. Isolated Areas: Effective dehumidification may require ducting be branched to isolated, stagnant areas. Use 8" or larger diameter branch ducting to each of two or three areas; use 4" or larger to each of four or more areas. Connecting to existing HVAC systems: An 8" check damper can be installed to prevent reverse flow through the unit. If the DRYCOOL HD is ducted to the supply of a high static air handler the check damper may be placed in the unit supply duct. Ducting Reactivation Air A separate set of duct connections are provided for the DRYCOOL HD dehumidifier for the reactivation air. The reactivation air is meant to convey the water vapor captured by the desiccant wheel away from the unit and outside the structure. The reactivation outlet connection is an 8" round connection located on the opposite side of the 14" W x 12" H air inlet. For total duct lengths up to 25, use a minimum 8 diameter round or equivalent rectangular duct. The duct should be brought to an outside wall or louver so that wet reactivation air is expelled from the space to the outdoors. Use a conventional dryer vent with back draft damper for penetrating the wall if convenient. Ducting for Fresh Air Fresh air can be brought into the structure by connecting a duct from outside to the DRYCOOL HD unit inlet and by turning on the fan switch or activating the humidity control. The fresh air duct must be connected to the return air duct of the DRYCOOL HD Dehumidifier. Additional considerations are as follows: 1.Outside air is filtered before entering the building. 2.Outside air will be dehumidified before entering if the unit is running in dehumidification mode. 3.Drawing air from outside and blowing inside aids in slightly pressurizing the structure. This helps prevent dirty and humid air from entering elsewhere. 4.Adequate exhaust fans are recommended in the bath rooms and kitchen. 5.Reactivation outlet must be seperated 4 from the Fresh Air inlet. The DRYCOOL HD is designed to move 250 cfm. An insulated 8" diameter duct is generally sufficient to provide up to 75 cfm of outside air. The remaining 175 cfm of return air can be mixed with this fresh air and ducted into the intake of the DRYCOOL HD.

1.1.2 Installation in Basement or Crawl Space with Existing Forced Air HVAC Sump Drain Conditioned Unventilated Basement Installation Sump Drain Ventilated Unconditioned Basement Installation If the existing system has multiple returns, select one to disconnect from the existing forced air system and use it for the dedicated DRYCOOL HD return. Always select a return from a central location in the structure in an area that is always open to the rest of the structure. Do not use a return from a room that often may have its door closed. If the structure in which the DRYCOOL HD is to be installed has an existing forced air HVAC system, utilize the HVAC system to make the DRYCOOL HD unit installation easier. Basement Installation: I nstall a separate 8" return duct for the DRYCOOL HD in a central area of the structure. Duct the supply of the DRYCOOL HD to an 8" x 8" x 8" tee/damper that is 20% open to the basement. Duct the other side of the tee to the air supply of the existing HVAC system. Connect an 8" reactivation duct to the reactivation outlet to expel moist air outside the basement. Crawl Space Installation: I nstall a separate return for the DRYCOOL HD

in a central area of the structure. Duct the supply of the DRYCOOL HD to an 8" x 8" x 8" tee/damper that is 20% open to the crawl space. Duct the other side of the tee to the air supply of the existing HVAC system. Connect an 8" reactivation duct to the reactivation outlet to expel moist air outside the crawl space. 1.1.3 Installation in an Attic with an Existing Forced Air HVAC Attic Installation ALWAYS install a secondary catch pan with a drain or float interrupt for condensate under the DRYCOOL HD in an attic. Locate a separate return for the DRYCOOL HD in a central area of the structure or draw air from return ductwork. Duct the supply side of the DRYCOOL HD to the air supply of the existing HVAC system. Connect an 8" reactivation duct to the reactivation outlet to expel this moist air outside the attic. 1.1.4 Installation for Dehumidifying for a Stand Alone Space

One of the benefits of a DRYCOOL HD is the delivery of dehumidified air to the space at approximately the same temperature that enters the device. This allows an owner to simplify the installation for applications or instances where it is desired to maintain humidity levels in one open space. In these applications the return air from the space is connected directly to the unit and the dehumidified air can be delivered directly back into the room without the need to mix it with cold air coming from a central air conditioning system. If the space is a large common room and is open to other adjacent rooms, using the DRYCOOL HD can have the effect of providing dehumidification to much larger connected areas or even a small structure. Water vapor diffuses from areas of high vapor pressure to areas of low vapor pressure. When large spaces are dehumidified with a DRYCOOL HD, areas of low vapor pressure are created and will induce water vapor movement from other connected open rooms without the need for ducting. The DRYCOOL HD requires the mounting a humidistat away from the discharge in an area that is representative of the larger space. As with all of the installation configurations of a unit, the reactivation air still needs to be ducted to and from the outdoors. 1.2 Electrical Requirements/Humidistat Installation The DRYCOOL HD plugs into a common grounded outlet on a 15 Amp circuit. It draws between 6 and 7 Amps under normal operating conditions. If used in a wet area, a ground fault interrupter protected circuit is required. If an extension cord is required, it must have a minimum of 16 gauge conductors if less t han 25 feet l ong and 14 gauge if greater than 25 feet long. Install the remote humidistat in a central area of the structure where it will sense the relative humidity of the structure accurately. Do not install the humidistat where it may not accurately sense the relative humidity such as near HVAC supply registers, near exterior doors, or near a pool or spa. The installer must s upply the wiring between the dehumidifier unit and the humidistat. Be sure to safely route the control wires to prevent damage during installation. Be careful not to cross the wires when connecting the DRYCOOL HD and the humidistat or damage to the transformer may result. The humidistat of the DRYCOOL HD is powered by a low voltage circuit and must NEVER contact or be connected to a high voltage circuit. The control wires leaving the unit and the humidistat are color coded to prevent confusion. Be sure to consult the electrical schematic on the panel of the DRYCOOL HD before making the control connections.

1.3 Condensate Removal CAUTION The DRYCOOL HD removes large amounts of moisture from the air and the device must be connected to a drain line that will carry away the excess water. A trap in the drain line is strongly recommended. The drain line should be connected to the 3/4 female pipe thread adaptor on the front of the DRYCOOL HD. Care should be taken to install the drain line with a continuous slope of 1" per 10' to assure proper water removal. An optional condensate pump may be installed if a lift is required to dispose of the condensate. CAUTION For additional safety, Munters always recommends that a catch pan with float switch be placed under the DRYCOOL HD. 1.4 Installation in a Structure with No Existing Forced Air HVAC When installing the DRYCOOL HD in a structure that does not have a forced air HVAC system, a single return for the DRYCOOL HD should be installed in a central open area of the structure. DO NOT locate the return in a bathroom or a kitchen. The supply of the unit should be located in the remote areas of the structure (such as bedrooms, den, etc...). By ducting this way the air inside the structure will circulate through the DRYCOOL HD to be filtered and dehumidified. 4 diameter duct is recommended for branches to the bedrooms, 6 diameter duct is recommended for branches to larger areas. Connect an 8 reactivation duct to the reactivation outlet to expel moist air outside the space. 2 Intended Application

Use of the DRYCOOL HD in pool areas will void warranty. In order to efficiently control humidity levels, the area in which the dehumidifier is to be placed must be free of water intrusion or excessive fresh air infiltration. Before installation of the DRYCOOL HD, water intrusion or excess air infiltration should be addressed. DO NOT use the DRYCOOL HD as a bench or table DO NOT place the DRYCOOL HD directly on structural members. A secondary drain pan MUST be placed under the unit. The DRYCOOL HD could be located near the existing air handling system to minimize the required ductwork. The controls for the DRYCOOL HD are remote from the unit and must be located in the space that is to be conditioned. The controls are low voltage (24 volt) and should be connected to the DRYCOOL HD with low voltage thermostat wire. If fresh air ventilation is desired, thought should be given to the location for the fresh air ducting. An insulated duct will have to be installed on the DRYCOOL HD and run to the outside of the structure to bring in fresh air. The unit is not meant to condition more than 75 cfm of outside air. Consult local codes for necessary distances from exhaust ports when installing fresh air return. Consult all applicable codes for proper installation. 2.1 Specification 3 Operation The DRYCOOL HD can be equipped with various accessories to enhance its operation. A remote humidistat must be used with the unit.

3.1 Humidity Control Adjustment Set the humidity control to the desired humidity level for the structure. The dehumidifier will run continuously until the relative humidity (RH) is reduced to the humidity control dial setting. Setting the humidity control to lower RH levels will NOT increase the unit s dehumidification rate; the unit will simply run longer to reduce the area s RH to the setting. The DRYCOOL HD will reduce a conditioned space s RH to a lower level. Settings below 40% are not recommended. 3.2 Fan/Filter Switch Turning ON the fan/filter switch on the side of the unit will cause the DRYCOOL HD internal fan to run continuously, w hether the unit is dehumidifying or not. This function is desirable if the unit is used for air circulation and filtration to achieve maximum indoor air quality. When the switch is ON; air will be constantly filtered through the unit and circulated throughout the house. When the switch is OFF; the fan will operate only when the humidity control calls for dehumidification. 4 Maintenance 4.1 Air Filter The DRYCOOL HD is equipped with an air filter. This filter should be checked every three months. Operating the unit with a dirty filter will reduce dehumidifier capacity and efficiency and may cause the compressor to cycle off and on unnecessarily. DO NOT operate the unit without a filter. The heat exchange coils inside the unit could become clogged and require disassembly to clean. CAUTION Servicing the DRYCOOL HD with its high pressure refrigerant system and high voltage circuitry presents a health hazard which could result in death, serious bodily injury, and/or property damage. Only qualified service people should service this unit. 5 Humidity Control The humidistat control is an adjustable switch that closes when the relative humidity of the air in which it is located rises to the dial set point. If the DRYCOOL HD does not run, try turning the humidity control until it reaches the stop and the knob pointer points at on. Since the 1950s BMIL Technologies, LLC 4915 Arendell St., #313 Morehead City, NC 28557 PH 252-727-0994 FAX 252-727-0996 WWW.BMIL.COM