DEHUMIDIFIER USER S MANUAL CFO-12E CFO-20E

Similar documents
SAVE. Features. Excellent drying laundry function. Powerful dehumidifying capability. Quiet operation

This dehumidifier is both compact and lightweight. The casters on the bottom of the unit make it easy to move from room to room.

PORTABLE DEHUMIDIFIER

DUE-1237 DEHUMIDIFIER Owner s Manual

Models GDNM16A5BK4AA GDNM20A5BK4AA GDNM24A5BK4AA DEHUMIDIFIER OPERATING INSTRUCTIONS

SUKI. Dehumidifier WDH-928DB -20R. User s Manual

12L Dehumidifier Model: HG00923

Dehumidifier. Instruction Manual. Model DH-320/A

AD-250. Dehumidifier OWNERS MANUAL. Read and save these instructions.

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

SH3020 USER INSTRUCTIONS

Dehumidifier. User Manual

DEHUMIDIFIER INSTRUCTION MANUAL. Table of Contents. English. Italiano. Svenska. Features Powerful Dehumidifying Drying inside Easy Dehumidifying

GDDEM10 DEHUMIDIFIER

30-pint Dehumidifier User Guide

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

15,000 BTU Portable Air Conditioner

ODE20: 20 LITRE DEHUIMIDIFIER

IMPORTANT SAFETY INSTRUCTIONS

INSTRUCTIONS Français 2 Nederlands 15 English 28 Italien

9 LITRE DESICCANT DEHUMIDIFIER INSTRUCTION MANUAL

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

Dehumidifier/Dryer. Model: EDV Please read the instruction manual before operating. Keep in a safe place for future reference

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

PDA20DX Air Purifying Dehumdifier Manual

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C120 TD-C160

User Manual. Tumble Dryer ZDC8202P

Operating Instructions Air Conditioner

MeacoDry ABC Range Dehumidifiers

Operating Instructions Air Conditioner

Air always contains a certain amount of water in the form of vapour. This determines the

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

Dehumidifier Owner s Manual Read and save these instructions before use

PORTABLE AIR CONDITIONER

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Instruction Manual. Hitachi Dehumidifier CONTENTS. Model. RD-170FX RD-230FX 1 Useful in the Following Cases RD-280FX 2 Cautions for Safety.

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

Owner s Manual Super-Slim Four-Way Cassette

PORTABLE AIR CONDITIONER (LOCAL)

IONIZER SS225 SS225. ionizer anti-mite

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

User Manual. Refrigerator ZRG16605WA

PAC12H. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C100

KSD-35 DR11 KUE-35 DVN11

Heat Pump / Air Conditioner

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

OWNER S MANUAL. Portable Dehumidifier: BHD-H Series BHDP-H Series R-410A

DESICCANT DEHUMIDIFIER

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

PORTABLE AIR CONDITIONER OWNER S MANUAL

USER MANUAL SILENT12 PORTABLE AIR CONDITIONER

DAIKIN ROOM AIR CONDITIONER. Operation Manual

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

DEHUMIDIFIER USER'S MANUAL. Dry Mec 16. VOLTAGE: V~50Hz CONTENTS

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

Mobile Air Conditioner Instruction Manual Model TC-N9KM

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

Ultrasonic Aroma Diffuser AD-SD1-CE

Operation manual. Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B. Operation manual Split system air conditioners

User Manual. Chest Freezer ZFC26500WA

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

IONIZER SS229 SS229. ionizer catechin

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

SAVE THESE INSTRUCTIONS

Operating Instructions Air Conditioner

Operating Instructions

REG-183J REG-253J RADS-151J RADS-183J RADS-253J RAD-283J

Dehumidifier. Model: GDN20AX-K4EBA1A GDN20AX-K4EBA1B

Operating Instructions Air Conditioner

Instruction Manual F KSTFD12AAG IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS. For Household Use Only

DOUBLE DOOR COMPACT REFRIGERATOR. User Manual MODEL:KSTRC312BW KSTRC312BB

Operating Instructions Air Conditioner

DD12E DEHUMIDIFIER USER'S MANUAL CONTENTS. VOLTAGE: V~50Hz

Notice d'utilisation. Benutzerinformation. Gebruiksaanwijzing User Manual. Kühlschrank. Refrigerator. Réfrigérateur. Koelkast S7212LS2P

USE & CARE INSTRUCTIONS

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

MITSUBISHI INSTRUCTION MANUAL. Table of Contents

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

Portable Air Conditioner

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

Dehumidifier. Instruction Manual

PORTABLE AIR CONDITIONER OWNER S MANUAL

5) Do not start or stop the unit by inserting or pulling out the power plug.

Thermo CTP-E45T 0 Pot

Transcription:

DEHUMIDIFIER USER S MANUAL CFO-12E CFO-20E

Contents Structure and principle Features Specifications How dehumidifying works? Structure of dehumidifier 1 2 3 4 Operation steps 6 Before using your dehumidifier, please read this user s manual carefully, in order to ensure correct and safe use. After reading the manual, make sure it is stored in a safe place for future reference if necessary. Operation Maintenance Operation panel Draining the water Caring for the dehumidifier Storing the dehumidifier Notation for safe operation 7 9 12 12 13 Removing breakdowns 14 Appendix Electric Schematic Diagram 18

Structure and Principle Features Powerful dehumidifying capability Taking advantage of refrigeration principle, the dehumidifier powerfully removes partial moisture from air to drop the humidity of the room and keep indoor air dry and comfortable. Quiet operation When the dehumidifier operates in QUIET mode, the value of its noise is so low and makes your room quiet. Excellent drying laundry function The dehumidifier dries laundry quickly. This can prevent laundry and furniture from becoming damp and musty in a rainy season. Drainage tank with a large capacity The drainage tank capacity is large to 6 liter, this will reduce the times of your discarding water. Using refrigerant for protecting environment Saving energy The dehumidifier uses the no CFC refrigerant for protecting environment to reduce to pollute environment. The power consumption is low. - 1 -

Structure and Principle Specifications Model CFO-12E CFO-20E Power Supply 220 230V, 50Hz Dehumidifying Capacity Power Consumption 12L/day 220W 20L/day 400W Drainage Tank Capacity 6.0L(automatic stop at about 5.5L) Weight 12.5kg 14kg Dimension(height width depth) 545mm 380mm 261.5mm The dehumidification capacity is the value obtained after the dehumidifier was continuously run in the room temperature of 30 with the relative humidity 80%. The amount of dehumidification is the amount per day(24 hours.) If specifications are changed without notice for further improvement, they are data on nameplate of the unit. The work temperature is in the range 2 to 38. If the room temperature is beyond the range, the unit can not operate normally. working temperqture range of maximum charge dehumidifying:35 C DB/26 C WB. - 2 -

Structure and Principle How dehumidifying works Moist air Compressor Cooling unit Re-heating unit Dried air Drainage tank It draws in room air, cools it with a cooling unit, and changes the humidity to drops of water. The drops of water fall into a drainage tank. The dehumidified air is re-heated by a heating unit and discharged. Steps,,and are repeated to remove humidity from the room. After the air passes through the re-heating unit, its temperature will rise a little, so that the temperature of the room will rise appreciably. This is normal phenomenon. - 3 -

Structure and Principle Structure of dehumidifier Handle Louver Discharge port Operation panel Plastic film Float Water level gauge Drainage tank NOTE: Please take off the plastic film before using. - 4 -

Structure and Principle Air filter (Air intake port, do not obstruct!) Continuous drainage port Power supply plug - 5 -

Operation Operation steps: 1. Plug the power supply plug into the outlet. 2. Open the louver by hand. 3. Press the power suitch. 4. Select operation mode or let it run in the default mode. 5. Press the power switch once again to stop operation. - 68 -

Operation Operation panel Indicator lamp 1.Tank full indicator lamp It will light when the drainage tank is full or positioned incorrectly. Empty the water out of the drainage tank, and make sure the tank is positioned properly. 2.Power indicator lamp It will light when the unit is plugged in. 3.mode indicator lamp When lamp or lamp or lamp is lighted, it respectively indicates that operation is in DEHUMI- DIFY, LAUNDRY or QUIET mode. 4.Humidity indicator lamp When 50% lamp, 60% lamp or 70% lamp is lighted, it respectively indicates that the current setting humidity is 50%, 60% or 70%. CON : Continuously dehumidity indicator lamp When CON lamp is lighted, it indicates that the operation is in CONTINUOUS mode. - 76 -

Operation Switch function 5. switch Press the switch once to start operation, press it again to stop operation. 6. switch Each time the switch is pressed, the operation mode changes in the order of DEHUMIDIFY, LAUN- DRY and QUIET and the corresponding mode indicator lamp will change with the operation mode. The default is DEHUMIDIFY. when the indoor temperature is above 35, the protection device is actuated, the unit only can operate in LAUNDRY mode and pressing switch is ineffective. 7. switch Press the switch to set the humidity of the room, which can be set in order of 50%, 60% 70% and continuous, the defanlt is continuous. When the relative humidity of the room is lower than your setting humidity, the operation will stop automatically. - 87 -

Operation Draining the water If the drainage tank becomes full (approx. 5.5 liters), the lamp lights to alert the user, operation stops automatically. Empty the water from the drainage tank and discard it. Drainage steps 1. Remove the drainage tank Lightly pressing on the sides of the tank with both hands, pull it gently out. Take hold of the handle, and then remove the tank, discard the water. Notation for drainage Do not remove the bubble packing from the float on the unit, in order to prevent water from leaking from the water tank onto household furniture. This can cause electrical shock and/or short-circuiting. If the drainage tank is dirty, wash it with cold or lukewarm water. Do not use detergent, scouring pads, chemically treated dustcloths, gasoline, benzene, thinner, or other solvents to clean it, as these can scratch and damage the tank and cause water to leak. When place back the drainage tank, press the tank firmly into place with both hands. If the tank is not positioned properly, the Ò Tank FullÓ sensor will be activated, and the dehumidifier will not operate. Check to make sure the guards are firmly attached to the tank. If they are not, the drainage tank will be harder to remove. Wait at least 30 minutes before removing the drainage tank, in order to prevent the water which still in the cooling unit from dripping out on the base plane. (If water has dripped, wipe it up.) - 9 -

Operation Draining the water Continuous drainage of water The unit has a continuous drainage port. Using a commercial hose (with an inner diameter of 15mm), the water in the drainage tank can be continuously drained out of the continuous port of the unit. When setting up the equipment for continuous drainage, always stop operation first and unplug the power supply plug. 1. Disconnect the drainage tank and open the continuous drainage port. Use nippers or a similar tool to cut away the continuous drainage port in the side of the main unit. 2. Push the hose into the continuous drainage port Pass a commercial hose (with an inner diameter of 15mm) through the continuous drainage port, and press it firmly into the drainage port in the main unit, make sure water does not leak. The level height of drain piping should always be not higher than the one of the drainage port, also drain piping should always be not plugged up, so the condensed water can be drained out successfully. 3.Return the drainage tank to its original position Check the hose periodically to make sure it is still connected and has not been obstructed. - 10 -

Operation Make sure at lease some place is provided around it when the unit is operating. Note: Please stop working and discard the water before move the dehumidifier. Tilt it within range of 30 degrees. - 11 -

Maintenance Caring for the dehumidifier Clean the air filter The air filter should be cleaned approximately once two week. First, Remove the air filter, then run a vacuum cleaner lightly over the surface of the air filter to remove dirt. If the air filter is very dirty, wash it with warm water and a neutral cleaning solvent and dry it thoroughly, attach the airfilter. Storing the dehumidifier When the unit is not to be used for a long period of time 1. Fold up the power supply cord and secure it to the holder. 2. Discard any water left in the drainage tank and wipe away any remaining drops with a cloth. 3. Clean the air filter. 4. Store the unit Package the unit to keep it free of dust, and keep it upstanding and store it at a cool and dry place. - 12 -

Maintenance Notation for safe operation When use the unit, please observe the following safety precautions: 1.When the unit works in LAUNDRY mode, keep it an appropriate distance away from the clothings, and prevent the water from dropping onto it. 2.Before clean the unit or when do not use it for along period of time, unplug the power supply cord. 3.Do not wash the unit with water also put the unit close to water,explosive or flammable things. 4.Do not set the unit close to heat-generating devices or near inflammable and dangerous article. 5.Never put your fingers or objects into the intake or discharge ports. 6.Do not sit or stand on the unit. 7.Discard water that has collected in the tank timely. 8.Do not run the dehumidifier in an closed area such as inside closets, or fire can take place. 9.Do not use the unit for special purposes such as edible items, objects of art or scientific materials are stored. 10.Install drain piping in a downhill grade to make sure that condensed water can be drained continuously. 11.If the supply cord is damaged, it must be replaced by the manufacture or its service agent or a similarly qualified person in order to avoid a hazard. - 13 -

Maintenance Removing breakdowns If a condition listed below occurs, please check the following items to help you to save your time and cost. Condition Cause What to do Has the power supply cord been disconnected? Plug the power supply cord into the outlet. The unit does not operate. Is the lamp blinking?(the tank is full or in a wrong position.) Discard the water in the drainage tank, and then reposition the tank. Is the temperature of the room above 38 or below 2. The protection device is actuated and the unit can not be started in case operation is under the bad environment (in that case,please do not use the dehumidifier). - 14 -

Maintenance The dehumidifying function does not work. Is the air filter clogged? Is air intake port or discharge port obstructed? Clean the air filter as instructed under Caring for the dehumidifier. Remove whatever is obstructing the discharge port or intake port. No air is discharged. Is the air filter clogged? Clean the air filter as instructed under Caring for the dehumidifier. Operation is noisy. Has the unit been poorly installed so it is tilted or unsteady? Is the air filter clogged? Use the unit in a stable, sturdy location. Prompt: Put a cushion under the unit and help to reduce operation noise. Clean the air filter as instructed under Caring for the dehumidifier. After the above condition has occurred and corresponding step is used but the breakdown can not be removed or other breakdown occurs, please contact the authorized service centers. - 15 -

Maintenance Removing breakdowns The following symptoms do not indicate a breakdown Symptom Reason The operation noise suddenly increases during use. The operation noise increases when the compressor is activated. The humidity do not drop. Is the room too big for the unit? Are windows or doors opened and closed frequently? Is there a device in the room such as a kerosene stove, which emits steam? Very little dehumidifying takes place, or none takes place. This happens if the temperature and/or humidity of the room is low. When the unit is first used, the discharged air smells musty. Because the temperature of the head exchanger rises abruptly, an unusual or musty odor may be produced for a moment. - 16 -

Maintenance The unit echoes. If the unit is used in a room with wood flooring or in a small room, it may echo. When operation is started or the operation mode is changed, an unusual noise is heard in main unit. The refrigerant may take some sound until circulation stabilizes. There are some stains left in the drainage tank. This is water left from the dehumidifying test conducted at the factory, it does not indicate a problem. The unit only can run in laundry mode and it is ineffective to press mode switch. When the temperature of the room is above 35 the protection device is actuated, so that the unit only can run in LAUN- DRY mode( the fan speed is high). The fan is running and the compressor does not work. If the unit is started within 3 minutes after the unit stops, the protection device is actuated, so that the compressor is started automatically after a delay of 3 minutes; or the automatic defrosting operation is activated and the compressor stops. - 17 -

APPENDIX Electric Schematic Diagram - 18 -