HD COMMUNICATOR. Features & Benefits: Unique continuous Redundant Routing capacity. Up to 20km reach on a single copper pair.

Similar documents
Added password for IP setup page : Password must be in IP format!

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Networked Access Control Panel. Installation Guide

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

Operating Instructions. For. Alarm Control Module. Model SSR 500

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

ECO N DATE DESCRIPTION OF CHANGE CHG

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

SMS GSM Alarm Messenger

ASCO PowerQuest Power Monitoring and Control Systems

System 9000TS Sequence of Events Recorder

Intelligent Security & Fire Ltd

Power & Instrumentation BU

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

DCS-100. intelligent damper control & monitoring system

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

An introduction to... Sigma

Segment design & and Bus Diagnostics

Monitoring Solutions

ECC-50/100C. Emergency Command Center

System 9000TS Sequence of Events Recorder

Consultant Specification AGILE Wireless Fire Detection System

RTK 9000TS system. MTL sequence of events recorder. Technical data MTL process alarm equipment

Universal fault annunciator for panel mounting

Intelligent addressable fire alarm control panel

FC724 Fire control panel

June 10, 2002 DF C S2424

Integrated Security Solutions

Complex alarming made simple

ADW 535 Line type heat detector

P2267 NETWORK INTERFACE

FC722 Fire control panel

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Interface Modules for SENTRI

Interfacing with the ADAM Module

Flostop TS D7E and A8E. Operation Manual

Instruction Manual SCD24. Read this document prior to installation. Contents

4 Channel Contact Closure SFP DIN Fiber Link System

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

IF-L/RF Protection Switch

DATAssure. Laboratory wireless alarm & monitoring system

PTE0705 Electric Fence Monitor

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

M2500 Engine Controller Installation Manual

Installation, Operating and Maintenance Manual

Smoke Detector and Siren. Manual

EasyTronic III MANUAL SERVICE

FC724 Fire control panel

Trusted fault tolerant technology

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

LORAIN CIP 4890/48120 DC Power System

FC722 Fire control panel

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

DESCRIPTION NOTE. Temperature and Humidity Sensors MODEL 1260B

SEL Arc-Flash Solutions

REMOTELY OPERATED STENCH GAS RELEASE SYSTEM. Front Panel View Remote Activated Stench Gas Release System 240 Volt AC Supply

Model A1700 Series Annunciator

Silent Alert Fire Safe System

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A

SIL725 Safety Annunciator

UltraSync Modular Hub

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

July 14, 1999 DF C-100.

New Silent Alert Fire Safe System

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

UNC100 Integra Manual

USER MANUAL FOR OPERATING SYSTEM

ACTIVE INFRARED BARRIER

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

STEAMPAK Series BurnerPAK BMS Burner Management Systems

CCU Family of Modules

Tri-Stack Smart System

ClampOn DSP Corrosion- Erosion Monitor

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

Product Information. PipeMonitor District Heating Monitoring with Leak Localisation

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

EUROFIRE Fire Control Panel

Call stations and extensions

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

THX-DL Data Logger USER & INSTALLATION MANUAL V

ACCURATE ELECTRONICS INC

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F

SEL Arc-Flash Solutions

IRIS Touch Firmware Enhancements and Additions from Version to Version

Transcription:

HD COMMUNICATOR Next Generation Communications for Railway Networks Features & Benefits: Unique continuous Redundant Routing capacity. Up to 20km reach on a single copper pair. Echelon & Ethernet connectivity. Full remote management from Central Site. Automatic fault & alarm reporting. The HD Communicator (HDC) enables remote multidrop communications over existing line side copper cables and enables vital, secure network communication to command and control end-points, including the Safetran HD Link Module. The HD Communicator provides Ethernet and Echelon Communications over dual routed networks utilising industrial Ethernet technology. All data is dual routed, to provide a highly resilient network. There is no time delay in providing redundant routing over the HD Communicator Network. The HD Communicator unit provides local Echelon open communications for up to fifteen Safetran HD link units. Echelon Connectivity at 1.25mbps is achieved between each of the HD Communicator units. Complies with EN50121-4, EN50124-1, EN50125-3, and EN50159-2. No field configuration required. Wide operating voltage range 9-32V. IP-62 construction. Ring, Star or Point to Point Topology. Hot swappable during maintenance.

FURTHER INFORMATION No field configuration of the HDC is required, with ease of installation and deployment being of paramount importance in the product design. Each HD Communicator unit on the network can be centrally addressed and managed both for faults and maintenance. WEB INTERFACE MANAGEMENT There are three management interfaces provided on the HDC, Web interface, Telnet and a local serial interface. The Web interface provides a variety of management information screens giving status and performance updates on: Alarms, lines, Neuron interface, and a full time stamped event log. Management via Telnet also has enhanced features for engineers to configure the HDC, update firmware and view a variety of performance stats. The HDC can be centrally managed with access control on each unit to provide protection

RING TOPOLOGY MANAGEMENT ECHELON <5Km POINT TO POINT Communication Links ECHELON RELAY

HD POWER UNIT Specification: OUTPUT: 14 VDC OUTPUT CURRENT MAX: 14A INPUT: 85 to 264 VAC FREQUENCY: The HD power unit (MOD11166) is specifically designed to power the family of Home and Distant communications equipment within the railway environment. The unit has six individually fused and monitored outputs suitable for both HD Link Modules and HD Communicator units. In the event of a fault in a host unit resulting in excess current, the power unit will be isolate the output and activate the alarm. All other outputs will continue to work as normal. Volt free alarm contacts are provided which can be link configured to NO or NC. To cope with the railway supply, the HD Power unit has a wide-input operating range. The unit is the same fit and form as the HD Communicator, which also aids quick field replacement. 47 to 440Hz OUTPUT TRIP TIME: 8A DELAYED: 1 Second REGULATION: +/- 2% EFFICIENCY FULL O/P: 85% OUTPUT NOISE @ 20 MHz B/W: <25mVP/P

HD LINK MODULE Safety Features: The HD Link Modules are designed to communicate over open transmission systems. The communications system plays no role in safety. Safety is built into the modules and the associated procedures. Configuration procedures contribute to health and safety. Each installation must be designed, checked, approved and tested by competent engineers. Inputs are opto-isolated. Inputs have continuous voltage removal test running to ensure any input referral is detected. Inputs are de-bounced they will only pick after 250ms of trigger voltage between 7.5V and 20V Software filtering to prevent energisation caused by AC voltages between 25Hz + 250Hz Sender & receiver unique addresses (ATCS) True message data from one path of processor firmware 32 bit CRC from complement path of processor firmware Timestamps to eliminate stale messages Message numbers to detect out of sequence messages Hot swappable during maintenance Unique check numbers on installation Outputs are transformer isolated Outputs will only pick with 2 different wave forms from different circuits, triggered by independent routes through the firewall Fail safe to off state SIL 4 NR Product acceptance