Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

Similar documents
AFC Cable Systems: the Cable Industry Leader for Over 80 Years

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

SECTION ELECTRICAL GENERAL PROVISIONS

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

Chapter 1 General... 5

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Fire Alarm Systems ARTICLE. Introduction to Article 760 Fire Alarm Systems. Part I. General

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

The Star Teck Extreme STE/STEX Series Connectors

DuraLife TM FPL. Installation Guide. UL 2196 Fire Rated Alarm Cables. Authorities Having Jurisdiction should be consulted before installation.

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Speedlock AMC Connectors...KA1. Armored Cable Connectors...KB1-KB5 Metal Clad Cable Connectors...KB1-KB5 Flexible Metal Conduit Connectors...

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Cable Connectors For Armored Cable, Flexible Metal Conduit, Interlocked AC-38 Cables, NM and SE Cable

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES

Michigan Chapter IAEI Annual Meeting Ann Arbor, Michigan Code Panel Questions December 5 th and 6 th, 2013

Carbon Heating Film. Failure to follow these instructions may result in fire, electrical shock, property damage, personal injury, or death.

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

Second Revision No. 601 NFPA [ Section No [Excluding

Brand Portable Power Cord & Control Cable Solutions

Installing Protectowire Linear Heat Detector

Flexible Power Cable DLO

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

INSTALLATION INSTRUCTIONS

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

I dedicate this book to the Lord Jesus Christ, my mentor and teacher. Proverbs 16:3 NOTICE TO THE READER ABOUT THE AUTHOR

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

Installation Instructions

C Electrical Connection Kit

Inspection Checklist Mechanical Rough in

SECTION ELECTRICAL IDENTIFICATION

Electricity Unit Notes. Agriculture Mechanics I

TABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

Electric Dryer Installation Instructions

NELSON HEAT TRACING SYSTEMS

FireSystems PROTECTOWIRE. Installing Protectowire Linear Heat Detector

DRYER INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Special Provision No. 683S28 December 2017

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

ARTICLE 760 FIRE ALARM SYSTEMS

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

HEATING CABLE RATINGS APPROVALS* Drexan Energy Systems, Inc. Kelowna, BC, Canada, V4V 1S5

FMP-MWS. (Discriminating Monitoring Well Sensor BriteSensor ) Installation Instructions

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

Installing Underfloor Heating Film. 1. Layout of electric underfloor heating systems

FMP-DVS. Monitoring Well Discriminating Vapor Sensor (BriteSensor ) Installation Instructions

NELSON HEAT TRACING SYSTEMS INSTALLATION

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

SECTION (15820) - AIR DUCT ACCESSORIES

29 IN. (73.7 CM) ELECTRIC DRYER INSTALLATION INSTRUCTIONS DRYER SAFETY

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

Electric Dryer Installation Instructions

IdealFILM. Do-It-Yourself Installation Manual

ELECTRIC DRYER INSTALLATION INSTRUCTIONS

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT ELECTRICAL POWER AND TRANSMISSION INSTALLERS. Test Code: 5922 Version: 01

Installation Instructions

MERIT SERIES Up Flow / Horizontal

Installation Instructions

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

ELECTRIC DRYER INSTALLATION INSTRUCTIONS

electronic wire pocket-picker edition 7/06 Low voltage electronic wire specialists

Installation Instructions 30 French Door Built-in Wall Ovens

ELECTRIC DRYER INSTALLATION INSTRUCTIONS

FMP-ULS UNIVERSAL LIQUID SENSOR INSTALLATION GUIDE

SECTION (15767) - UNIT HEATERS

SECTION DUCTWORK

MERIT Series R-410A - Upflow / Horizontal

Bathroom Exhaust Fan

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 27 COMMUNICATIONS SECTION PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

MERIT Series R-410A - Upflow / Horizontal

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

SECTION (16075) - IDENTIFICATION FOR ELECTRICAL SYSTEMS

Connecting Lighting & Controls

Installation Instructions

FMP-DDS & FMP-DTS. Discriminating Dispenser Sump & Turbine Sump BriteSensor. Installation Instructions

Ilnstallat!on. nstruct=ons. Before You Begin. Parts Included. Tools Needed. Built-In Wall Oven with Microwave ATTENTION INSTALLER

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

CHAPTER 15 PART IV NATIONAL ELECTRICAL CODE, 2017

HVAC Equipment Access Equipment Location

FMP-DIS & FMP-EIS. Interstitial BriteSensor & Standard Sensor. Installation Instructions

Transcription:

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire. Installs fast and easy Lowers labor costs Replaces conduit and wire Provides superior grounding UL Listed

Corra/Clad MC Cable provides total installed, cost savings Contractors looking to save on labor during the installation of power are making CCI s Corra/Clad the cable of choice in place of conduit and wire. Corra/Clad consists of THHN soft drawn annealed copper conductors (solid or stranded), with UL type TFN or TFFN insulation. Conductors are cabled with fillers, and wrapped with an overall solid Flexi-Rib seamless, continuous, aluminum sheath, which provides watertight protection. Corra/Clad can also be furnished with a PVC jacket over the sheath for use in corrosive environments or direct burial. Flexi-Rib Design is Unique Flexi-Rib is a breakthrough in cable sheath design. It provides all of the benefits of interlocked metal, with none of the disadvantages. Corra/Clad is watertight, bends and stays and can be shaped to tight angles, unlike steel armor cable which cannot be used in wet applications, springs out of position, and doesn t conform to tight angles. Corra/Clad is quicker and easier to install than conventional pipe and wire. The lightweight aluminum armor means that Corra/Clad weighs less than steel armored cable, it s also easier to strip back. The flexible aluminum allows for ease of installation in one step. Corra/Clad saves time and money by eliminating conduit assembly, cutting and wire pulling. Corra/Clad needs no special tools or anti-short bearings. It can be cut to length and stripped in a matter of seconds with ordinary wire cutters. Once formed, it stays put, the bending radius is seven times the external diameter of the sheath, which eliminates wasted cable caused by larger diameter bends.

Corra/Clad design is unique Corra/Clad is lightweight, easy to work, and tough Corra/Clad s sheath is solid aluminum, which makes it more than 50% lighter than interlocked armor cable, yet it can stand up to the roughest use including severe environments. Corra/Clad can be quickly channeled in one continuous length through the hollow space in a ceiling or without 10 splices or couplings. TYPE TFN, TFFN OR THHN INSULATION COPPER CONDUCTOR FILLERS SEPARATION TAPE CORRA/CLAD FLEXI-RIB ALUMINUM SHEATH Here are just some of the benefits you get with Corra/Clad Costs can be cut by up to 65% More than 50% lighter Meets or exceeds all code requirements of NEC Article 330 UL approved Crush resistant Waterproof Pull easily Bends and stays Can be run in long continuous lengths Highly versatile, can be used for numerous applications No special tools needed Comes in easy to handle reels Highly corrosion resistant OPTIONAL PVC JACKET Installs quick and easy No other cable installs faster than Corra/Clad. It installs using the same type of fasteners that are used with EMT or armored cable and can be terminated in outlet or junction boxes using Type MC fittings. Here s how easy it is: Score Using a knife or cable cutters, score the sheath all the way around at the desired length. Separate Grip cable with both hands on either side of the score, flex and separate. Strip Strip sheath from cable by pulling firmly. Cut Cut away the protective tape and fillers. Spot Spot the connector at the proper location in the enclosure and tighten with a lock nut. Secure Firmly seat cable end into connector and secure in place by tightening connector with screwdriver while pressing in on the cable. 1 SCORE 2 3 STRIP 4 SEPARATE CUT 5 SPOT 6 SECURE

Corra/Clad MC Cable Aluminum Sheath Part# Part # Size of Nom. O.D. Inches Weight Ground Size Solid Stranded Conductor Inches Solid Stranded lbs/1000ft Equivalence* 92852 18/2 0.335 0.355 40 8 92853 18/3 0.345 0.370 49 8 92854 18/4 0.370 0.395 58 6 92652 16/2 0.355 0.370 47 8 92653 16/3 0.370 0.390 61 6 92654 16/4 0.395 0.415 75 6 92452 14/2 0.380 0.400 69 6 92453 14/3 0.390 0.415 88 6 92454 14/4 0.415 0.445 108 6 92252 92202 12/2 0.410 0.435 91 6 92253 92203 12/3 0.430 0.455 119 6 92254 92204 12/4 0.460 0.495 172 6 92152 10/2 0.475 0.530 153 5 92153 10/3 0.495 0.560 198 5 92154 10/4 0.565 0.600 245 3 Corra/Clad MC Cable For Hospitals & Nursing Homes (With Green Insulated Ground Wire) Aluminum Sheath Part# Part # Size of Nom. O.D. Inches Weight Ground Size Solid Stranded Conductor Inches Solid Stranded lbs/1000ft Equivalence* 92483 14/2 W/G 0.390 0.415 88 6 92484 14/3 W/G 0.415 0.445 108 6 92485 14/4 W/G 0.450 0.480 130 6 92283 92273 12/2 W/G 0.430 0.455 119 6 92284 92274 12/3 W/G 0.460 0.495 172 6 92285 92275 12/4 W/G 0.500 0.535 206 2 92183 92173 10/2 W/G 0.495 0.560 198 5 92184 92174 10/3 W/G 0.565 0.600 245 3 92185 92175 10/4 W/G 0.610 0.640 295 2 * When using EXCLUSIVE sheath as a ground, this is the approximate gauge size that the aluminum sheath provides Note: Other sizes and custom engineered designs available, contact Coleman Cable, Inc. Applicable Codes for Corra/Clad NEC Article 225.10 Wiring on Buildings 250.118 (10) Types of Equipment Grounding Conductors 300.22 (B) Ducts or Plenums Used for Environmental Air 330 Metal Clad Cable: Type MC 392.3 (A) Wiring Methods 396.10 (A) Messenger Supported Wiring Cable Types 501.10 (B) Class 1, Division 2 502.10 (B) Class II, Division 2 503.10 (A) Class III, Division 1 & 2 511.7 Commercial Garages, Repair & Storage 513.7 (A) Aircraft Hangers Wiring and Equipment Not Installed in Class I Locations Fixed Wiring 515.7 (A) Bulk Storage Plants Wiring and Equipment Above Class I Locations Fixed Wiring 516.7 (A) Spray Application, Dipping and Coating Process Wiring and Equipment Not Within Class I and II Locations Wiring NEC Article 517.10 Health Care Facilities 518.4 Assembly Occupancies Wiring Methods 520.5 Theaters, Audience Areas of Motion Picture and Television Studios, Performance Areas and Similar Locations Wiring Methods 530.11 Motion Picture and Television Studios and Similar Locations Permanent Wiring 604.6 (A)(1) Manufactured Wiring Systems Cables 610.11 Cranes and Hoists Wiring Method 620.21 Elevators, Dumbwaiters, Etc. - Wiring Methods 645.5 (D) (2) Information Technology Equipment Under Raised Floors 725.11(B) Remote-Control, Signaling, and Power-Limited Circuits Safety Control Equipment Physical Protection 760.52 (B) Fire Alarm Systems PLFA Wiring Methods and Materials 800.3 Communications Circuits

with the versatility and safety you need. Applications for Corra/Clad are varied and many. Corra/Clad MC Cable uses are governed by the National Electric Code Article 330 and applicable local codes, applications include the following: For services, feeders and branch circuits For power, lighting, control and signal circuits Indoors, exposed or concealed Direct buried or in concrete encasement (with PVC jacket) As aerial cable on a messenger (with PVC jacket) In cable trays or as open runs Under raised floors, and above suspended ceilings Outdoors or in wet locations (with PVC jacket) Plenums Any air handling passageway Hazardous (classified) environments Specialized applications Corra/Clad has become the wiring method of choice in health care facilities. The outer jacket is an approved grounding means and employs a continuous gas/vapor tight aluminum sheath which permits it to be used in hospitals and health care facilities, including patient areas. Corra/Clad with a solid aluminum sheath is ideal for ducts or plenum applications because unlike interlock sheath constructions, it does not allow smoke to chimney through the cable. The Fire/Clad product is preferred for fire alarm installations. The jacketed product is suitable for direct burial underground or in concrete.

COLEMAN CABLE OFFERS A COMPLETE LINE OF ELECTRICAL AND ELECTRONIC PRODUCTS FOR INDUSTRIAL, HOME TECHNOLOGY, ELECTRONIC, DATACOM AND SECURITY APPLICATIONS. Coleman Cable is a leading manufacturer and innovator of wire and cable products. Our product offerings are extensive and include: portable cord, machine tool wire, extension cords, thermostat wire, voice/data, coaxial, fire alarm, electronic as well as custom-engineered cable. Our Signal, Baron, Seoprene, Polar/Solar and Road Power brands are universally recognized for their market leadership positions. Our relentless commitment to product quality is complemented by a technical expertise that s coupled with extensive manufacturing capabilities. We are devoted to providing unmatched customer service and offer programs designed to provide our customers exceptional value in today s competitive market place. Extensive product offerings, technical expertise, a dedicated effort for customer service and an ongoing commitment to provide product innovation are some of the reasons for Coleman Cable s leadership in the wire and cable industry. 1530 Shields Drive Waukegan, IL 60085 800-323-9355 Fax: 847-689-1192 www.colemancable.com LT505-06-01 Printed in USA CCI6001 0406