» WITH REGASORP ROTARY HEAT EXCHANGER

Similar documents
AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

The New Sorption Rotary Heat Exchanger

recooler HP EQKR HEAT PUMP

eq PRIME » ENERGY EFFICIENCY AND FLEXIBILITY STRAIGHT OUT OF THE BOX AIR COMFORT AIR TREATMENT AIR HANDLING UNITS

ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit

EU Air Handling Units with SEMCO EXCLU-SIEVE

ClimaFläkt. Chillers and condensing units

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

LYRA » ENERGY EFFICIENT CASSETTE CHILLED BEAM AIR DIFFUSION LYRA

Efficient energy recovery in AHU. DOHA, Qatar Timo Schreck Enventus AB, Sweden

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

GOLD RX/HC. The air handling unit with a reversible heat pump. Ventilation, heating and cooling all in one

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

Energy Recovery with Cooling and Heating

THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

CONDENSATION/HUMIDITY PROBLEMS IN BREWERIES

MODBUS RS485 TECHNICAL INSTRUCTIONS

Adsorption Chillers Energysmart Green Cooling

COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS

White paper Compressed air drying

Trane CDQ Desiccant Dehumidification

Economical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

HEALTHCARE SURGERY VENTILATION HUMIDITY CONTROL

COTES ALL-ROUND THE C65 RANGE

Flexomix A versatile range of modular air handling units

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

Menerga Adconair Various solutions one heat recovery system

Principles of Active Desiccant Operation. Presented by Tom Peterson, CEO and Founder. Climate by Design International

AIR HANDLING THERMAL CONDITIONS

NEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart!

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

LIVING. For heat recovery in multi-occupancy buildings with extract air ventilation. And excellent return on investment.

ASCENDANT CONVENTIONAL COOLING, ACTIVE DESICCANT DEHUMIDIFICATION SYSTEM ASCENDANT LOW DEW POINT EFFICIENT & EFFECTIVE

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

COTES ALL-ROUND THE C65 RANGE

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

IPSUM OPTIMIZATION SYSTEM» DEMAND CONTROLLED VENTILATION OVERVIEW

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

DEHUMIDIFIERS & VENTILATORS

VAV CHILLED BEAMS Pi FUNCTION DESIGN GUIDE

Heat Pump Water Heater Commercial Leaflet 2012

Liquid desiccant dehumidification systems. Product guide

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

next generation R 1 cycling refrigerated compressed air dryers flow capacity: scfm ( Nm 3 /hr)

CONTROLLED CHILLED BEAM PUMP MODULE

Air Management for Food Applications

Air conditioning. EcoCond EcoCond+

COTES ALL-ROUND THE C105 RANGE

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

Material and rotor description.

National Institutes of Health Building 37 Modernization Bethesda, Maryland MECHANICAL DEPTH EXISTING MECHANICAL SYSTEM

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

CAIRfricostar CAU Controller with Remote Control SUPPLEMENT TO OPERATION MANUAL

> > > Heat pump systems. Water Chillers. Dehumidifiers

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

HVAC Mandatory Provisions Part II, Page 1

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 81,1 TO 182 kw, AIRFLOW FROM TO m 3 /h

Multi-Denco. » Precision Climate Control. Air Conditioning & Heating. Multi-DENCO

Technical Data Sheet

Liquid Desiccant Air Conditioning Systems

Energy Recovery Ventilation

By MIKE WEST, PHD, PE Advantek Consulting Inc. Melbourne, Fla.

DAIKIN Air Handling Unit Modular

The ultimate in air handling units: directly and indirectly fired

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

NET ENERGY WATER LOOPS A clear path to net zero energy buildings

INSTITUTE FOR ENVIRONMENTAL RESEARCH & SUSTAINABLE DEVELOPMENT NATIONAL OBSERVATORY OF ATHENS (NOA)

Advanced rotor technology. from the market leader within desiccant dehumidification DESICC ANT WHEELS

Trane Performance Climate Changer Air Handlers. An air handler for every need.

SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER

The ultimate in air handling units: directly and indirectly fired

DVU-HP. Integrated Reversible Heat Pump System

Why should you opt for ENTHALPY. Wheels for your. AHUs. ERVs. (Energy Recovery Ventilators) (Air Handling Units) from

Refrigerants & Cooling in renovation buildings

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

COTES FLEXIBLE THE CRP/CRT-RANGE

Beijing Holtop Artificial Environment Technology Co., Ltd

GEA Air Handling Units Modular configuration. Integrated refrigeration with optimized energy efficiency GEA CAIRplus.

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

Desiccant Cooling Analysis Simulation software, energy, cost and environmental analysis of desiccant cooling system

Cold Storage Warehouse Dock Parametric Study

To Keep Docs Cool, Dry and Happy

The ultimate in air handling units: directly and indirectly fired

Air-cooled Screw Chillers Model RTAF G Process

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

Trane Performance Climate Changer Air Handlers. An air handler for every need.

ABOUT US OUR EXPERTISE WHAT IS ENERGY RECOVERY? ERV (Energy Recovery Ventilation) AHU (Air Handling Units) PAC (Package Air Conditioning Equipment)

cotes flexible Dehumidification the way you want it cotes.com crp/crt

PRODUCT CATALOGUE THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

OPERATING INSTRUCTIONS

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

CAIRplus ECOTWINcool SUPPLEMENT TO OPERATION MANUAL

HYBRID GAS HEAT PUMP WATER HEATER WITH THERMAL EFFICIENCY 120% 23rd World Gas Conference, Amsterdam Main Author. Atsuya Tajima Japan

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

Product Brochure Modular Air Handling Units CAIRplus. Multiflow liquid-coupled energy recovery system

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Transcription:

AIR TREATMENT eq AIR HANDLING UNITS REGASORP» WITH REGASORP ROTARY HEAT EXCHANGER

eq WITH REGASORP ROTARY HEAT EXCHANGER REDUCES COST UP TO 50% Two of the most important factors affecting indoor air climate are the air temperature and the humidity. Achieving comfort conditions can be very expensive, but our RegAsorp rotary heat exchanger radically reduces that cost by up to 50%. Rotary heat exchangers offer high efficiency in a compact design and often provide the best return on investment. We offer two types of rotary heat exchangers: REGOTERM for sensible energy transfer and RegAsorp for both latent and sensible energy transfer. BETTER ENERGY RECOVERY DURING SUMMER The main feature of the RegAsorp rotor is that it can not only transfer heat energy but also moisture. When warm outdoor air is cooled, the moisture in the air condenses to water when the air reaches the dew point. This takes a lot of energy and requires that the chiller is designed to cope with it. BETTER HUMIDITY LEVEL DURING THE WINTER In the winter time, the outdoor air contains very little moisture and when it is heated to room temperature it will cause very dry conditions indoors. By recovering the moisture in the extract air with our RegAsorp rotor, the supply air is humidified and we maintain a higher level of moisture indoors than we would have with other heat recovery systems. BETTER ENERGY RECOVERY DURING THE WINTER On very cold days, normal heat exchangers can become frosted and performance drops rapidly. To avoid this it is necessary to employ defrosting systems which will cost additional energy in one way or another. When using the RegAsorp rotor the moisture in the extract air is recovered and transferred to the supply air. Frost will not accumulate in the wheel and maximum heat recovery will be available all the way down to around -24 C saving both energy costs and installation costs. The RegAsorp rotor will support by transferring a large part of the moisture in the outdoor air and exhausting it directly through the exhaust fan. This means the size of the cooling system is reduced.

In chilled beam systems it is necessary to control the humidity of the air to avoid condensation. Usually this means reducing the supply air humidity to approx 8 g/kg in order to keep the air dew point in the room below the chilled beam temperature. The following example compares the installed capacity and the energy ergy consumption for a unit with a non hygroscopic wheel and a RegAsorp rotor. The same conditions are used in both cases. The cooling power needed to cool air from 26 C, 60% (21 C wet bulb) is app 32 kw for each cubic meter per second of air. For 5 m 3 /s that means 160 kw. Below we see how we can reduce that with a rotary heat exchanger. Installed colling power, kw 180 160 140 120 100 80 60 40 20 160 125 70 The installed cooling capacity is reduced from 160 kw to 70 kw and the energy consumption is reduced by 1700 kwh. This brings a significant reduction in the size of the chiller and cooling energy savings. 0 Total cooling power Sensible wheel RegAsorp Wheel Energy recovered Cooling power needed REGASORP - MINIMAL CARRY OVER The RegAsorp rotor has minimal carry over on the rotor surface. It is treated with a Molecular Sieve desiccant, that captures water by using adsorption principle, but does not collect bacteria. The pores on the rotor surface are just a couple of Ångström in diameter. A water molecule is able to be transferred in the desiccant but since bacterias are larger than 1000 Å they will not be transferred on the surface. Extract Air Supply Air

THE REGASORP ROTOR BRINGS BENEFITS IN ALL SEASONS CASE 1 - SUMMER CONDITIONS When cooling warm outdoor air, the moisture in the air condenses to water. This takes a lot of energy and requires that the chiller is sized to managed that. This is especially important in systems requiring special control of the humidity. Chilled beam systems are a common example. HOW? The RegAsorp rotor is able to dehumidify and cool the outdoor air by transfering the heat and moisture to the exhaust air. BENEFITS Reduced Cooling energy consumption Minimizing carry-over Downsizing of cooling system: - Smaller chiller installation - Smaller cooling circuit: pumps, valves, pipes etc - Reduces refrigerant quantities in buildings 24 C, 45% 32 C, 12g/kg, 40% 25 C, 9g/kg 13,5 C, 8,5g/kg 15 C Reduction of cooling peak load by more than 50% due to efficient cooling recovery

CASE 2 - WINTER CONDITIONS Heat recovery systems often face frost problems on cold winter days. The problem occurs when the humidity in the exhaust air condensates on the recovery system and turns into ice with the impact on reduced recovery and increased pressure losses in the device which in the end blocks the air flow totally in the AHU. To avoid this scenario most recovery systems are equipped with frost protection which cost energy and money. The RegAsorp rotor can solve the frost problem. HOW? The RegAsorp rotor recovers the moisture in the extract air and transfers it to the supply air which means frost will not accumulate on the rotor and maximum heat recovery will be available down to app -24 C saving both energy and installation costs.. BENEFITS Reduced heating energy cost by avoiding defrosting Reduced heating system size Higher moisture content in the supply air; which means better comfort and more hygienic indoor climate Enhanced reliability in the winter due to reduced frosting problem 22 C, 30% Supply air humidity increases from 15% to 30% with a RegAsorp rotor -5 C, 2g/kg 17 C, 4,5/kg 20 C, 30% (15%)

ReCOOLER HP WITH REGASORP - THE PERFECT COMBINATION Our ReCooler HP offers an air handling unit with an integrated DX cooling system. There is no need to mount cooling equipment on the roof of the building and installation is quick and simple as the ReCooler HP is factory tested and ready to run after local inspection requirements have been fulfilled. With our RegAsorp rotor you you will get superior cooling recovery combined with an exceptionally high COP. This product contains fluorinated greenhouse gas, R410A, with a GWP-factor of 2088. Refrigerant quantity: 3,8 11,8 kg, corresponding to 7,9 24,6 tonnes of CO 2 equivalent. THE EFFECTS OF DRY AIR ON COMFORT AND HYGIENE In winter time, especially in climates with low outdoor air temperature, there is an issue for most applications due to too dry indoor air. Optimal humidity level indoors should be approximately 40-50% The dry indoor air has an impact on humans in: Health problems like allergics, flu symptoms, dry throats etc.

ACON SELECTION TOOL Easy-to-use and powerful selection. ACON is a powerful and easy product selection tool for air handling units. It is the best and most advanced of its kind on the web. It offers rapid product selection to specific project requirements and provides you with all the technical information. Product dimensions Noise data Performance data Efficiency data Life cycle cost Product documentation Export of Dxf and Dwg files LCC CALCULATIONS To make an informed choice when making your investment in an air handling unit, the overall life cycle cost calculation is an important metric to consider. FläktGroup has developed a sofisticated calculation tool that provides you with the yearly energy cost and life cycle cost. A large number of data sources are taken into account, including detailed climate information, heating and cooling recovery equipment and all relevant energy consumption points etc. The LCC calculation tool is integrated in ACON for maximum ease of use. Energy, Economy and Expertise with FläktGroup Energy optimization is an important aspect of creating a healthy and cost-effective indoor climate, and an area in which FläktGroup have acclaimed expertise. We use the symbol e3 to highlight products and solutions that are particurlarly effective. They serve a dual purpose of saving both your long-term economy and our environment.» flaktgroup.com

FG_DC_-2018-9244-GB_BR_eQ with regasorp_r0-2018-03-28 Copyright 2018 FläktGroup WWW.FLAKTGROUP.COM FläktGroup is the European market leader for smart and energy efficient Indoor Air and Critical Air solutions to support every application area. We offer our customers innovative technologies, high quality and outstanding performance supported by more than a century of accumulated industry experience. The widest product range in the market, and strong market presence in 65 countries worldwide, guarantee that we are always by your side, ready to deliver Excellence in Solutions. PRODUCT FUNCTIONS BY FLÄKTGROUP Air Treatment Air Movement Air Diffusion Air Distribution Air Filtration Air Management Air Conditioning & Heating Controls Service» Learn more on www.flaktgroup.com or contact one of our offices eq WITH REGASORP