ASTM E 84 Surface Burning Characteristics of "12 mm Stratificato Panel"

Similar documents
CAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"

CAN/ULC-S102 Surface Burning Characteristics of "ezobord 9 mm (Green)"

CAN/ULC-S102 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum

CAN/ULC-S102.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate"

ASTM D Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

Test Report No. AJFS FF Date: OCT.17, 2018 Page 1 of 6

Certificato numero: 300 RIVA TECNOIMPIANTI S.R.L. UNI EN ISO 9001 : 2015 ISO 9001 : 2015

Report Of Surface Burning Characteristics Tests On PVC Sheeting As Submitted By Jain (Americas) Inc.

CAN/ULC-S109 Flame Resistance of "Argo" Fabric

FUNDERMAX GMBH FIRE TEST REPORT

CAN/ULC-S109 Flame Resistance of "Xanadu" Material

Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors

We Identify and S.T.O.P. Your Noise Problems

Report Of Surface Burning Characteristics Tests On Fire Retardant Coating As Submitted By Contego International

Contents: 4. Report of Surface Burning Characteristics Tests on LP FlameBlock/BlazeGuard (30-minute test) Updated April, 2010

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc.

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy LLC

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

Report of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd

SIGMADEK, LTD. FIRE TEST REPORT

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Railtech Ltd.

Report of Surface Burning Characteristics Test on Acoustical Panel

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Ebrille SRL

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Textures 3D

Acoustical Surfaces, Inc.

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198"

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

Report of Surface Burning Characteristics Tests on Samples As Submitted By Jotun UAE Ltd (LLC)

GUARDIAN FIRE TESTING LABORATORIES, INC.

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd

TEST REPORT. Contact No: SAMPLE NOT DRAWN BY OUR LABORATORY. THE RESULTS RELATE ONLY TO THE ITEMS TESTED

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

BS 476: Part 6: 1989+A1:2009

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme:

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

BS EN ISO : 2010

Glass fibre rovings - Non-metallic materials

BS EN ISO : 2010

GLUE APPLICATION SYSTEMS DESIGN AND DEVELOPMENT

BS EN ISO : 2010

BS EN : 2001 & IEC :2000

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

Product Data Sheet Trespa HPL Panels

Review Fire Test Report

ISO INTERNATIONAL STANDARD

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

BUILDING CATALOGUE

BS 476: Part 6: 1989+A1:2009

FRANCE M & F RANKING ACCORDING TO NF F

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

Abrasion Resistance of Fluoropolymer and polyester Coatings

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Measurement of force - UNI EN 12453(2002) point 5 30,0 33,0

NF X : Parts 1, 2, 3, 4 & 5

FACADES AND FIRE The Essential Elements

Public Comment No. 2-NFPA [ Section No ]

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Contact person Date Reference Page Richard Johansson P (2) Fire Research

PUBLIC SUMMARY REPORT OF THE EGOLF EN 13823

Owner's Letter of Assurance

BCTC CARPET TECHNICAL CENTRE

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

IMO Resolution MSC 61(67): Annex 1: Part 2

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS

Fire protection. DECORATIVE PANELS Fire protection

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ARCHITECTURE 2018-REV:00

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Measurement of force - UNI EN 12453(2002) point 5. C % U.R. Slow-down speed: Opening slow-down torque: Closing slow-down torque: 33,0 28,0

Cleanroom Materials Flammability Test Protocol

CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation


CANADIAN FIRE ALARM ASSOCIATION An Update on Standards, Technologies and Solutions. Smoke Characterization Study

DECORATIVE PANELS Individual. Individual. Ideal for individual, unique projects Your motif becomes a design The latest digital printing technology

C-01 FIRE DECKS AND BULKHEADS

Report on the Fire Testing of a Roofing System with a Synthetic Underlayment in Accordance with ASTM E a. Trinity ERD Columbia, SC

Fire Safety Evaluation of Existing Manufactured Educational Building Covered by Section 423 of the Florida Building Code

AirGuard Coating. Ceiling. For Ultima Ceiling Panels. A revolutionary breakthrough to actively remove formaldehyde in buildings

CAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL?

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

PART 1 GENERAL 1.01 SUMMARY

Transcription:

UNCONTROLLED ELECTRONIC COPY ASTM E 84 Surface Burning Characteristics of "12 mm Stratificato Panel" A Report To: ABET Inc. 60 West Sheffield Avenue Englewood, NJ 07631 USA Phone: 201-541-700 Web: www.abetlaminati.com E-mail: sales@abetlaminati.com E-mail (Canada): on@abetlaminati.com Submitted by: Exova Warringtonfire North America Report No. 13-002-733 4 Pages Date: January 2, 2014

ASTM E 84 Testing of "12 mm Stratificato Panel" Page 2 of 4 For: ABET Inc. Report No. 13-002-733 ACCREDITATION To ISO/IEC 17025 for a defined Scope of Testing by the International Accreditation Service Exova SPECIFICATIONS OF ORDER Determine the Flame Spread and Smoke Developed Indices based upon a single test conducted in accordance with ASTM E 84-13a, as per Exova Warringtonfire North America Quotation No. 13-002-270,389 accepted December 5, 2013. SAMPLE IDENTIFICATION (Exova sample identification number 13-002-S0733) High pressure laminate phenolic panel material, identified as: "12 mm Stratificato Panel" TEST PROCEDURE The method, designated as ASTM E 84-13a "Standard Method of Test for Surface Burning Characteristics of Building Materials", is designed to determine the relative surface burning characteristics of materials under specific test conditions. Results are expressed in terms of Flame Spread Index (FSI) and Smoke Developed (SD). Although the procedure is applicable to materials, products and assemblies used in building construction for development of comparative surface spread of flame data, the test results may not reflect the relative surface burning characteristics of tested materials under all building fire conditions. SAMPLE PREPARATION The test sample consisted of 3 sections of material, each approximately 0.5 inches (12 mm) in thickness by 21 inches (533 mm) in width by 96 inches (2438 mm) in length. The sections were butted together to form the requisite specimen length. Prior to testing, the sample was conditioned to constant weight at a temperature of 73 ± 5 F (23 ± 3 C) and a relative humidity of 50 ± 5%. During testing the sample was self-supporting. The testing was performed on: 2013-12-20 SUMMARY OF TEST PROCEDURE The tunnel is preheated to 150 ± 5 F (66 ± 2.8 C), as measured by the floor-embedded thermocouple located 23.25 feet (7087 mm) downstream of the burner ports, and allowed to cool to 105 ± 5 F (40.5 ± 2.8 C), as measured by the floor-embedded thermocouple located 13 feet (3962 mm) from the burners. At this time the tunnel lid is raised and the test sample is placed along the ledges of the tunnel so as to form a continuous ceiling 24 feet (7315 mm) long, 12 inches (305 mm) above the floor. Three 8 foot (2438 mm) sections of 0.25 inch (6 mm) cement board are then placed on the back side of the sample end-to-end, to protect the tunnel lid, and the lid is then lowered into place.

ASTM E 84 Testing of "12 mm Stratificato Panel" Page 3 of 4 For: ABET Inc. Report No. 13-002-733 SUMMARY OF TEST PROCEDURE (continued) Upon ignition of the gas burners, the flame spread distance is observed and recorded every second. Flame spread distance versus time is plotted. Calculations ignore all flame front recessions and Flame Spread Index (FSI) is determined by calculating the total area under the curve for the test sample. If the area under the curve (A) is less than or equal to 97.5 min ft, then FSI = 0.515 A; if greater, FSI = 4900/(195-A). FSI is then rounded to the nearest multiple of 5. Smoke Developed (SD) is determined by dividing the total area under the obscuration curve by that of red oak, and multiplying by 100. SD is then rounded to the nearest multiple of 5 if less than 200. SD values over 200 are rounded to the nearest multiple of 50. Exova TEST RESULTS Flame Spread Smoke SAMPLE Index (FSI) Developed (SD) "12 mm Stratificato Panel" 10 15 Observations of Burning Characteristics - The sample ignited approximately 119 seconds after exposure to the test flame Surface blistering and spalling behavior was observed. - The flame front propagated to a maximum distance of 5.5 feet (1.7 metres) at approximately 591 seconds. Authorities having jurisdiction usually refer to these categories: Flame-Spread Index Smoke Development Class 1 or A 0-25 450 Maximum Class 2 or B 26-75 450 Maximum Class 3 or C 76-200 450 Maximum Note: This is an electronic copy of the report. Signatures are on file with the original report. Robert A. Carleton, Technologist. Ian Smith, Technical Manager. Note: This report and service are covered under Exova Canada Inc. Standard Terms and Conditions of Contract which may be found on the Exova website (www.exova.com), or by calling 1-866-263-9268.

ASTM E 84 Testing of "12 mm Stratificato Panel" Page 4 of 4 For: ABET Inc. Report No. 13-002-733 FLAME SPREAD INDEX "12 mm Stratificato Panel" 20 18 RED OAK (FSC=100) 16 SAMPLE Exova Flame Spread in Feet 14 12 10 8 6 4 2 0 0 60 120 180 240 300 360 420 480 540 600 Time in Seconds SMOKE DEVELOPED 100 90 80 RED OAK (SD=100) SAMPLE "12 mm Stratificato Panel" % Light Absorption 70 60 50 40 30 20 10 0 0 60 120 180 240 300 360 420 480 540 600 Time in Seconds Flame Spread Smoke Index (FSI) Developed (SD) 10 15

CERTIFICATO Nr. 50 100 14305 Si attesta che / This is to certify that IL SISTEMA QUALITÀ DI THE QUALITY SYSTEM OF ABET LAMINATI S.p.A. SEDE LEGALE E OPERATIVA: REGISTERED OFFICE AND OPERATIONAL SITE: VIALE INDUSTRIA 21 IT - 12042 BRA (CN) SEDE OPERATIVA: OPERATIONAL SITE: STRADA FALCHETTO 30 IT - 12042 BRA (CN) È CONFORME AI REQUISITI DELLA NORMA HAS BEEN FOUND TO COMPLY WITH THE REQUIREMENTS OF UNI EN ISO 9001:2008 QUESTO CERTIFICATO È VALIDO PER IL SEGUENTE CAMPO DI APPLICAZIONE THIS CERTIFICATE IS VALID FOR THE FOLLOWING SCOPE Produzione di laminati decorativi HPL e CPL. Produzione di pannelli compositi con anima in nido d'ape di alluminio o di altri materiali, pannelli compositi in tessuto di vetro, altre fibre e resine termoindurenti (IAF 14, 17) Per l Organismo di Certificazione For the Certification Body TÜV Italia S.r.l. Validità /Validity Dal / From: 2018-01-04 Al / To: 2018-09-14 Data emissione / Printing Date Andrea Coscia Direttore Divisione Management Service 2018-01-04 PRIMA CERTIFICAZIONE / FIRST CERTIFICATION: 2007-07-03 LA VALIDITÀ DEL PRESENTE CERTIFICATO È SUBORDINATA A SORVEGLIANZA PERIODICA A 12 MESI E AL RIESAME COMPLETO DEL SISTEMA DI GESTIONE AZIENDALE CON PERIODICITÀ TRIENNALE THE VALIDITY OF THE PRESENT CERTIFICATE DEPENDS ON THE ANNUAL SURVEILLANCE EVERY 12 MONTHS AND ON THE COMPLETE REVIEW OF COMPANY'S MANAGEMENT SYSTEM AFTER THREE-YEARS

CERTIFICATE OF COMPLIANCE ABET LAMINATI Stratificato - Compact Laminate 14620-410 Certificate Number 05/04/2009-05/04/2018 Certificate Period Certified Status UL 2818-2013 Standard for Chemical Emissions for Building Materials, Finishes and Furnishings Commercial furniture and furnishings are tested in accordance with ANSI/BIFMA M7.1-2011(R2016) and determined to comply with ANSI/BIFMA X7.1-2011(R2016) and ANSI/BIFMA e3-2014e Credit 7.6.1 in an Open Plan Office environment. Products tested in accordance with UL 2821 test method to show compliance to emission limits in UL 2818, Section 7.1. UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively Agreement ). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.

GREENGUARD Certification Criteria for Building Products and Interior Finishes Criteria CAS Number Maximum Allowable Predicted Concentration Units TVOC(A) - 0.50 mg/m³ Formaldehyde 50-00-0 61.3 (50 ppb) µg/m³ Total Aldehydes (B) - 0.10 ppm Particle Matter less than 10 µm (C) - 50 µg/m³ 4-Phenylcyclohexene 4994-16-5 6.5 µg/m³ Individual VOCs (D) - 1/10th TLV - (A) (B) (C) (D) Defined to be the total response of measured VOCs falling within the C6 C16 range, with responses calibrated to a toluene surrogate. Maximum allowable predicted TVOC concentrations for GREENGUARD (0.50 mg/m³) fall in the range of 0.5 mg/m³ or less, as specified in CDPH Standard Method v1.1. The sum of all measured normal aldehydes from formaldehyde through nonanal, plus benzaldehyde, individually calibrated to a compound specific standard. Heptanal through nonanal are measured via TD/GC/MS analysis and the remaining aldehydes are measured using HPLC/UV analysis. Particle emission requirement only applicable to HVAC Duct Products with exposed surface area in air streams (a forced air test with specific test method) and for wood finishing (sanding) systems. Allowable levels for chemicals not listed are derived from 1/10th of the Threshold Limit Value (TLV) industrial work place standard (Reference: American Conference of Government Industrial Hygienists, 6500 Glenway, Building D-7, and Cincinnati, OH 45211-4438). UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively Agreement ). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.

CERTIFICATE OF COMPLIANCE ABET LAMINATI ABET High Pressure Laminate Restrictions: 6617-410 Certificate Number 05/04/2009-05/04/2018 Certificate Period Certified Status UL 2818-2013 Standard for Chemical Emissions for Building Materials, Finishes and Furnishings Commercial furniture and furnishings are tested in accordance with ANSI/BIFMA M7.1-2011(R2016) and determined to comply with ANSI/BIFMA X7.1-2011(R2016) and ANSI/BIFMA e3-2014e Credit 7.6.1 in an Open Plan Office environment. Products tested in accordance with UL 2821 test method to show compliance to emission limits in UL 2818, Section 7.1. UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively Agreement ). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.

GREENGUARD Certification Criteria for Building Products and Interior Finishes Criteria CAS Number Maximum Allowable Predicted Concentration Units TVOC(A) - 0.50 mg/m³ Formaldehyde 50-00-0 61.3 (50 ppb) µg/m³ Total Aldehydes (B) - 0.10 ppm Particle Matter less than 10 µm (C) - 50 µg/m³ 4-Phenylcyclohexene 4994-16-5 6.5 µg/m³ Individual VOCs (D) - 1/10th TLV - (A) (B) (C) (D) Defined to be the total response of measured VOCs falling within the C6 C16 range, with responses calibrated to a toluene surrogate. Maximum allowable predicted TVOC concentrations for GREENGUARD (0.50 mg/m³) fall in the range of 0.5 mg/m³ or less, as specified in CDPH Standard Method v1.1. The sum of all measured normal aldehydes from formaldehyde through nonanal, plus benzaldehyde, individually calibrated to a compound specific standard. Heptanal through nonanal are measured via TD/GC/MS analysis and the remaining aldehydes are measured using HPLC/UV analysis. Particle emission requirement only applicable to HVAC Duct Products with exposed surface area in air streams (a forced air test with specific test method) and for wood finishing (sanding) systems. Allowable levels for chemicals not listed are derived from 1/10th of the Threshold Limit Value (TLV) industrial work place standard (Reference: American Conference of Government Industrial Hygienists, 6500 Glenway, Building D-7, and Cincinnati, OH 45211-4438). UL Environment investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL Environment and the Certificate Holder (collectively Agreement ). The Certificate Holder is authorized to use the UL Environment Mark for the identified Product(s) manufactured at the production site(s) covered by the ULE Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified dates unless there is non-compliance with the Agreement.

CERTIFICATO Nr. 50 100 14314 - Rev.001 Si attesta che / This is to certify that IL SISTEMA DI GESTIONE AMBIENTALE DI THE ENVIRONMENTAL MANAGEMENT SYSTEM OF ABET LAMINATI S.p.A. SEDE LEGALE E OPERATIVA: REGISTERED OFFICE AND OPERATIONAL SITE: VIALE INDUSTRIA 21 IT - 12042 BRA (CN) SEDE OPERATIVA: OPERATIONAL SITE: STRADA FALCHETTO 30 IT - 12042 BRA (CN) È CONFORME AI REQUISITI DELLA NORMA HAS BEEN FOUND TO COMPLY WITH THE REQUIREMENTS OF UNI EN ISO 14001:2015 QUESTO CERTIFICATO È VALIDO PER IL SEGUENTE CAMPO DI APPLICAZIONE THIS CERTIFICATE IS VALID FOR THE FOLLOWING SCOPE Progettazione, sviluppo e produzione di laminati decorativi HPL e CPL. Produzione di pannelli compositi con anima in nido d ape di alluminio o di altri materiali, pannelli compositi in tessuto di vetro, altre fibre e resine termoindurenti, attraverso processi di impregnazione, pressatura, squadratura e ruvidatura (IAF 14) Design, development and production of HPL and CPL decorative laminates. Production of composite panels with aluminum or other material honeycomb core, production of composite panels with glass fibre, other fibres and thermosetting resins whit impregnation, pressing, trimming and sanding processes (IAF 14) CERTIFICAZIONE RILASCIATA IN CONFORMITÀ AL REGOLAMENTO TECNICO ACCREDIA RT-09 CERTIFICATION ISSUED IN ACCORDANCE TO ACCREDIA TECHNICAL REGULATION RT-09 Per l Organismo di Certificazione For the Certification Body TÜV Italia S.r.l. Validità / Validity Dal / From: 2018-02-09 Al / To: 2021-02-08 Data emissione / Printing date: Andrea Coscia Direttore Divisione Management Service 2018-02-08 PRIMA CERTIFICAZIONE / FIRST CERTIFICATION: 2012-02-10 LA VALIDITÀ DEL PRESENTE CERTIFICATO È SUBORDINATA A SORVEGLIANZA PERIODICA A 12 MESI E AL RIESAME COMPLETO DEL SISTEMA DI GESTIONE AZIENDALE CON PERIODICITÀ TRIENNALE THE VALIDITY OF THE PRESENT CERTIFICATE DEPENDS ON THE ANNUAL SURVEILLANCE EVERY 12 MONTHS AND ON THE COMPLETE REVIEW OF COMPANY'S MANAGEMENT SYSTEM AFTER THREE-YEARS