Technical Information OUSAF12

Similar documents
Technical Information OUSAF22

Technical Information OUSAF44

Technical Information OUSAF21

Technical Information OUSTF10

Technical Information OUSBT66

Technical Information OUSBT66

Technical Information OUSTF10

Operating Instructions OUSAF12

Operating Instructions OUSTF10

Condumax CLS16 and CLS16D

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

OMA-300 Process Analyzer

Instruction Manual. optek-sensors AF56. optek-danulat GmbH Emscherbruchallee Essen

Turbimax CUE21 / CUE22

Only for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power Maximum radiation intensity Detection pattern

Operating Instructions Indumax CLS54D

Operating Instructions. Condumax CLS15/16/21. Analog sensors For conductive measurement of conductivity in liquids BA01148C/07/EN/01.

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Laser Distance Sensor Type M Analog-Output

Operating Instructions Condumax CLS15/16/21

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Turbimax CUE21 / CUE22

An FT-NIR Primer. NR800-A-006

PUV, PIR and PFO Series BROCHURE

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

APPLIED. OMA-406R Rackmount Process Analyzer

COMPACT FLAME CONTROLLER CFC 2000

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

SPECTRAL INSTRUMENTATION

Specifications Wavelength Range: 190 nm to 800 nm continuous

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

COMPACT FLAME CONTROLLER CFC 1000

X56 Series Photometric Detectors

818 Series Low-Power Detectors

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Instruction Manual. gray Housed Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

Indumax CLS50/CLS50D. Operating Instructions. Analog or digital sensors with Memosens protocol For inductive measurement of conductivity in liquids

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

Druck DPI 705/DPI 705 IS Series

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

Control 4000 Photometric Analyzers Control 8000 Universal Analyzers

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

Level Measurement Continuous level measurement Ultrasonic transmitters

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

Control 4000 Photometric Analyzers Control 8000 Universal Analyzers

Turbidity Systems. Inline Turbidity Measurements For More Visibility Into Your Process. INGOLD Leading Process Analytics

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

Flame Detection Jon Sarfas

Temperature Measurement Transmitters for field mounting

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

SIMRAD GD10 IR GAS DETECTOR

The new generation of Multi-Gas measurement. Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control

ATEX Safety Instructions. DYNHRT3MMSS Line Rider

Application Overview: SmartSwitch

Rosemount 4500 Hygienic Pressure Transmitter

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

SECTION Fluorescent Dissolved Oxygen Measuring System

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Gas cylinder scale Model GCS-1

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

GAS DETECTOR ST400EC PART.NO

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

Dräger PIR 7200 Toxic Gas Detection Transmitter

Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

INSTALLATION GUIDE Ultrasonic Sensors Series UPR-A Atex

Model 144H. Product Data Sheet , Rev DB February Content

Control Panels Switchgear Motors Generators Analysers Rooms/Buildings. Pressurized Enclosure. Static Pressurization. Leakage Compensation (LC)

Model 144H. Product Data Sheet , Rev DB February Content

Lamp Supply (Recommended)

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Continuous Gas Analyzers, in-situ

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

Ultrasonic Level Measurement nivopuls FDU 10 S

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510

BC-HTO RELIABLE SENSING TECHNOLOGY

Class 1 laser beam sensor safe for your eyes

SECTION ph/orp Sensors

Manual Power relay SR853

The SharpEye 40/40I (IR3) Flame Detection

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

Easy installation Certified for zones 1 and 21 High IP degree of protection

SIMRAD GD10L - IR GAS DETECTOR OPERATING MANUAL

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Micro/Ultra Filtration System StamoClean CAT 430

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Transcription:

TI00497C/07/EN/02.16 71316923 Products Solutions Services Technical Information OUSAF12 Optical sensor combined with the OUA260 flow assembly for absorbance measurement Application The sensor is used to determine the VIS/NIR absorption of a liquid medium. Suspended solids measurement Pharmaceuticals and biotechnology Chemical industry Paper and pulp industry Interphase detection Food and beverage industry Chemical industry Oil and gas industry Centrifuge and separator control Your benefits Quality control and enhanced production efficiency thanks to reliable absorption measurement Measuring range up to 2.5 AU or 50 OD (depending on optical path length) Can be configured to measure absorption at discrete wavelengths in the visible regionand NIR region Color-independent measurement with optional broadband filter Incandescent lamp for long service life and stable measured values Cost-effective, time-efficient verification (liquid-free) FM- and ATEX-approved lamps for applications in the hazardous area Deployable and durable in numerous applications: Variety of materials and process connections Hygienic design for high degree of product safety: certified materials and CIP/SIPresistance Can be adapted to process requirements: Optional air purge ports to prevent the formation of condensate on the optical windows

Function and system design Measuring principle Light absorption The measuring principle is based on the Lambert-Beer law. There is a linear dependency between the absorption of light and the concentration of the absorbing substance: A = -loga m = ε. c. OPL A... absorption, A m... absorption measured by detector ε... Extinction coefficient c... Concentration OPL... Optical path length A light source emits radiation through the medium and the incident radiation is measured on the detector side. The intensity of the light is determined by a photodiode and converted to a photocurrent. The subsequent conversion to absorbance units (AU, OD) is performed in the associated transmitter. 1 OPL 2 3 A m 2 5 4 1 Absorption measurement 1 Light source 2 Optical windows (assembly) 3 Detector 4 Measurement filter (depends on sensor, not provided on all sensors) 5 Medium flow A0029401 Measuring system An optical measuring system comprises: Sensor (photometer) OUSAF12 Liquiline CM44P transmitter Cable set CUK80 Assembly to suit the sensor, e.g. OUA260 2 Endress+Hauser

1 2 7 3 6 5 4 2 Example of a measuring system with a photometer sensor 1 pipe 5 Flow assembly OUA260 2 Transmitter CM44P 6 Sensor: light source (lamp) 3 Cable set CUK80 7 Cable set CUK80 4 Sensor: detector Input Measured variable Measuring range Wavelength process absorption 0 to 2.5 AU Max. 50 OD (depending on the optical path length) Broadband, NIR (780 nm+), 400 nm, 420 nm, 430 nm, 540 nm, 950 nm and 1134 nm Power supply Electrical connection The sensor is connected to the transmitter using the pre-terminated or labeled cable set CUK80 (for connection to CM44P) or OUK10 (for connection to CVM40). The terminals and labeling may vary depending on the transmitter in use. The cable set must be ordered separately. Endress+Hauser 3

YE YE A B GY RD 3 OUSAF12 connecting cable A Light source (lamp) power supply B Signals of detector A0028383 CM44P terminal CVM40 terminal Cable color Assignment P+ V1.1 YE (thick) Lamp voltage + S+ V1.3 YE (thin) Detection of lamp voltage + P- V1.2 (thick) Lamp voltage - S- V1.4 (thin) Detection of lamp voltage - A (1) S1.1 RD Measuring detector sensor + C(1) S1.2 Measuring detector sensor - SH (1) S1.S GY Shield Cable length Maximum 100 m (330 ft) Lamp voltage Sensor version Lamp type Lamp voltage [V] OUSAF12-xxAxx Single beam, standard incandescent lamp 3.4 ± 0.1 OUSAF12-xxBxx Single beam, collimated incandescent lamp 4.9 ± 0.1 OUSAF12-xxCxx Single beam, high-luminescence lamp 4.9 ± 0.1 OUSAF12-xxDxx Single beam, gas-filled high-performance lamp 4.9 ± 0.1 Versions for use in hazardous areas Safety instructions for electrical apparatus in explosion-hazardous areas, XA01403C Connecting the detector using a safety barrier The photometer sensors use silicon photovoltaic cells as detectors which are operated in the current mode. The detectors are intrinsically safe and can be deployed in Zone 1 environments. The safe area is separated from the hazardous area by one safety barrier MTL7760AC. 4 Endress+Hauser

90 (3.54) 105 (4.13) 12.6 (0.5) 4 Safety barrier, dimensions in mm (inch) The safety barrier may only have a very low leak current since the optical signals from the sensor can be in the nanoampere range. Therefore, the sensor cable shield is connected to the ground terminal of the barrier. On delivery, the CUK80 detector cable is permanently wired to the safety barrier. All you have to do is simply connect the individual cable ends to the detector and transmitter. Photometer (Det.) MTL7760ac CM44P RD 3 4 GY 1 2 RD GY C (1) A (1) SH (1) Connecting the hazardous area lamp using a junction box The hazardous area lamp (EXP-1) must be connected to the transmitter using a certified junction box. For versions with FM approval, the junction box is included in the delivery and already preterminated on the lamp side. You simply have to connect the cable of the transmitter (CUK80) to the terminals of the junction box. For versions with ATEX approval, the junction box is not included in the delivery and it and the cable glands required must be provided by the customer at the place of installation. You must connect the cables entirely on your own (CUK80 of transmitter and lamp cable of photometer sensor). Endress+Hauser 5

EXP-1 ATEX II 2G Ex db IIC T5 Gb FM Cl.1, Div. 1, Groups B, C, D YE YE CM44P P+ S+ S- P- PE 27 30 5 Connecting the hazardous area lamp to CM44P using a junction box A0029440 Installation Installation instructions A D B E C 6 Mounting angles. The arrows indicate the direction of medium flow in the pipe. A Preferred mounting angle B Optimum mounting angle C Acceptable mounting angle D Mounting angle to be avoided E Forbidden mounting angle A0028250 6 Endress+Hauser

Environment Ambient temperature range Storage temperature 0 to 55 C (32 to 130 F) -10 to +70 C (+10 to +160 F) Humidity 5 to 95 % Degree of protection IP 65 (NEMA 4) for all optical parts Process Process temperature Process pressure 0 to 90 C (32 to 194 F) continuous Max. 130 C (266 F) for 2 hours Max. 100 bar (1450 psi) absolute, depending on the material, pipe size and process connection of the flow assembly Mechanical construction Design, dimensions C A B 7 Sensor module A Dimension of lamp, depends on lamp type, see table B Dimension of detector, see table C Assembly, see Technical Information for assembly A0028304 Lamp type Dimension A in mm (inch) High-luminescence lamp and standard incandescent lamp 33.78 (1.33) Gas-filled lamp 33.78 (1.33) Collimated incandescent lamp 151.3 (5.96) Detector type Dimension B in mm (inch) Standard version with test filter 101.6 (4.0) Easycal 101.6 (4.0) The total length of the sensor module is derived from the lengths of the lamp, the detector and the assembly. The dimensions of the OUA260 assembly are provided in Technical Information, TI00418C. Endress+Hauser 7

When connecting the sensor cable, make sure you maintain an additional distance of 5 cm (2") on both the lamp side and the detector side of the sensor. Weight 1.225 kg (2.7 lbs.), without flow assembly Materials Sensor housing Stainless steel 316L OUA260 assembly Cable connection ends Stainless steel 316, 316L or Kynar or customer-specific material Depends on version Nickel-plated brass Light source High-luminescence lamp (wavelength filter 450 nm and above) Gas-filled high-performance lamp (wavelength filter below 450 nm) Collimated incandescent lamp (enhanced resolution) Standard incandescent lamp Lamp operating life: typically 10 000 h Detector UV silicon detectors, hermetically sealed Filter Multilayer narrow-band interference filter Certificates and approvals mark Declaration of Conformity The product meets the requirements of the harmonized European standards. As such, it complies with the legal specifications of the EC directives. The manufacturer confirms successful testing of the product by affixing to it the mark. Ex approvals ATEX II 2G Ex db IIC T5 Gb FM Cl.1, Div. 1, Groups B, C, D FDA conformity All non-metal parts in contact with medium, such as rubber and plastic parts, meet the requirements of FDA 21 CFR 177.2600. The plastic and elastomer parts of the sensor in contact with medium have passed the biological reactivity tests according to USP <87> and <88> Class VI. Ordering information Product page www.endress.com/ousaf12 Product Configurator On the product page there is a "Configuration" button to the right of the product image. 1. Click this button. The Configurator opens in a separate window. 2. Select all the options to configure the device in line with your requirements. In this way, you receive a valid and complete order code for the device. 3. Export the order code as a PDF or Excel file. To do so, click the appropriate button on the right above the selection window. For many products you also have the option of downloading CAD or 2D drawings of the selected product version. To do so, click the "CAD" tab and select the desired file type using dropdown lists. 8 Endress+Hauser

Scope of delivery The scope of delivery consists of the following depending on the version ordered: sensor Detector and lamp module without flow assembly or Detector and lamp module mounted on OUA260 flow assembly Operating Instructions If the sensor is ordered with a transmitter, the complete measuring system is factory-calibrated and shipped as one package. If you have any questions, please contact your supplier or your local sales center. Accessories The following are the most important accessories available at the time this documentation was issued. For accessories not listed here, please contact your service or sales office. Flow assembly OUA260 Flow assembly for hygienic sensors For sensor installation in pipes Materials: stainless steel 316, 316L or Kynar (other materials available on request) Wide variety of process connections and path lengths available Product Configurator on the product page: www.endress.com/oua260 Technical Information TI00418C Cable CUK80 cable set Pre-terminated and labeled cables for connecting analog photometer sensors Product Configurator on the product page: www.endress.com/cuk80 Endress+Hauser 9

www.addresses.endress.com