Brazed Plate Heat Exchanger for CO Applications

Similar documents
Ammonia. Background on ammonia as a refrigerant

investment in R&D, the commitment to - name.

compact BOOSTER RACK TRANSCRITICAL CO 2 Cooling capacity LT: from 2 to 130 kw Cooling capacity MT: from 20 to 300 kw

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

CO2 TRANSCRITICAL BOOSTER SYSTEMS

FACT SHEET 9 Large Air-Conditioning (air-to-air)

System Design, Commissioning, Operation

Brazed Plate Heat Exchanger

η second law = Second law efficiency

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

TRENDS IN RETAIL INDUSTRY REFRIGERATION & REVIEW OF EUROSHOP 2017 EXHIBITION

Chapter 2. Alternatives to HCFCs and their Characteristics

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008

HFCs or the Old Refrigerants - what is the best Choice?

A Comparison Between Refrigerants Used In Air Conditioning

Transcritical CO2 Bottle Cooler Development

CO 2 transcritical FTE System Full Transcritical Efficiency

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Evaluation of HCFC Alternative Refrigerants

Commercial CO2 Refrigeration Systems. Guide for Subcritical and Transcritical CO2 Applications

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

CHAPTER 1 INTRODUCTION

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Chapter 10. Refrigeration and Heat Pump Systems

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

SUBCRITICAL & TRANSCRITICAL SYSTEMS

Brazed plate heat exchangers. For the refrigeration industry

CHAPTER 1 INTRODUCTION

From the Field to the Supermarket

INDUSTRIAL REFRIGERATION. Position on refrigerant selection

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

Environmentally friendly refrigeration systems for industrial use

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

Refrigerant Dryers DRY with PDP Indicator

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Study of R161 Refrigerant for Residential Airconditioning

Commercial CO 2 Refrigeration Systems

Energy Use in Refrigeration Systems

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.

Brazed heat exchangers

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Campbell Soup Company Extends Use of CO2 Systems Into Their Operations

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

"ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range

PACKAGED REFRIGERATION EQUIPMENT

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

REVERSIBLE R744 (CO 2 ) HEAT PUMPS APPLIED IN PUBLIC TRAINS

Pack Calculation Pro. Users guide. Version Morten Juel Skovrup

Information for practitioners 5. Refrigerant selection guidelines. An overview of the refrigerants of the future.

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Navigating a changing refrigerants market

The Current Path of Refrigerants

NATURAL REFRIGERANT SYSTEMS

REFRIGERATION AND AIR CONDITIONING

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Process glycol chillers

Compendium DES July 2016, CARN

Advantages of R290 (Propane) and other hydrocarbons

THE BIG FIVE NATURAL REFRIGERANTS IN DIFFERENT INDUSTRIAL APPLICATIONS. MAYEKAWA EUROPE S.A.,Leuvensesteenweg 605, 1930 Zaventem, Belgium

THE INSTITUTE OF REFRIGERATION

Natural refrigerants - naturally efficient

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

Kirby CO 2 Evaporators

Large AC units using a variety of low-gwp options

Chapter 1 Preface & General

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

FACT SHEET 6 Transport Refrigeration

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

DTI Kenneth Bank Madsen Global Application Expert Food Retail

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

COMPANY PROFILE. F ounded in 1970, Kaori's goal is the pursuit of modernization of heat-treating

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Thermodynamics II Chapter 5 Refrigeration

Global Solutions for Ammonia Industrial Refrigeration

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

Development of Environmentally Benign Heat Pump Water Heaters for the US Market

Brazed Plate Heat Exchanger

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

Transcription:

Brazed Plate Heat Exchanger for CO Applications www.kaori-bphe.com

CO 2 (R744) Due to global warming, climate change phenomenon, and rising restriction on the use of high GWP synthetic refrigerant; replacing HCFC and HFC by natural refrigerants has gained importance. HVAC system manufacturers are using natural refrigerant instead of HCFC and HFC in their latest products, in order to take a part in slowing global warming. The environment-friendly CO 2 HVAC is growing in the vehicle air conditioning systems, heat pumps HVAC and house heating markets. Hydrocarbon refrigerants are usually composed of flammable substances with high potential risk. In contrary CO 2 (R744) is classified as non-flammable and non-toxic fluid, having zero ODP (Ozone Depletion Potential) and minimal GWP (Global Warming Potential) of 1. It also has excellent thermodynamic properties making it one of the most popular natural refrigerants to replace HCFC and CFC. CO 2 (R744) is suitable for range of application such as industrial heat extraction, modern heating or refrigeration technologies, and as well biotechnology industry such as supercritical extraction, with the environment-friendly characteristic of supercritical CO 2. Brazed Plate Heat Exchanger Brazed Plate heat exchangers are compact designed with high efficiency, size only 1/3 of shell and tube heat exchanger, made by stainless steel with high pressure strength, higher corrosion resistance, and most importantly with longer usage life. Brazed plate heat exchangers are now the most preferred engineering design of various system manufacturers, such as refrigeration, air conditioning, heat pump system, hydraulic cooling, industrial processes and other industries can be seen on the application of brazed plate heat exchanger. KAORI High-pressure C series brazed plate heat exchanger is dedicatedly designed for various uses of CO 2 systems. KAORI has successfully developed our latest C series exchanger to a high pressure resistance, higher heat transfer performance and smaller size heat exchanger, with all its advantages, C series heat exchanger not only breakthrough the restrictions of traditional heat exchanger, but also enlarge the benefits of R744 (CO 2), and fulfill various CO 2 system applications and designs.

Super High Pressure BPHE KAORI C series is specially designed for R744 (CO 2), in supercritical, transcritical and subcritical system applications, can be used as gas cooler, condenser, evaporator,economizer, cascade, heat recovery, (suction line heat exchanger), and intercooler of heat pump in refrigeration, and supercritical extraction industries. Designed with different maximum working pressure resistance, at 70 bar, 100 bar and 140 bar, available for various duties and different performance specifications, with compact size, outstanding heat transfer efficiency and low pressure drop are the three key features of KAORI C series. The quality and the durability of C series is proved by field tests, achieving the burst test pressure up to 650 bar and cycle test over 100,000 cycles. C Series Specifications 186 92 Unit: mm 106 50 77 40 73 40 522 466 613 519 311 278 191 154 C020/C021/C022 C040/C041/C042 C095/C096/C097 C200/C201/C202 Model Thickness (mm) Weight*(kg) Without Connection Heat Transfer Area/ Plate (m 2 ) Total Heat Transfer Area (m 2 ) Volume/ Channel (liter) Total Volume (liter) Pressure (bar) Min. Test Pressure (bar) Temperature C020 C021 C022 C040 C041 C042 C095 C096 C097 C200 C201 C202 9.5+1.10*N 9.5+1.10*N 9.5+1.10*N 13.0+2.00*N 13.0+2.00*N 13.0+2.00*N 13.2+2.16*N 13.2+2.16*N 13.2+2.16*N 14.0+2.15*N 14.0+2.15*N 14.0+2.15*N 1.12+0.042*N 1.14+0.042*N 1.126+0.042*N 1.74+0.145*N 1.83+0.145*N 1.75+0.152*N 5.52+0.320*N 5.68+0.320*N 5.90+0.346*N 12.39+0.603*N 12.56+0.631*N 12.41+0.755*N 0.01109 0.01109 0.01109 0.0193 0.0193 0.0193 0.0475 0.0475 0.0475 0.095 0.095 0.095 (N-2)*0.01109 (N-2)*0.01109 (N-6)*0.01109 (N-2)*0.0193 (N-2)*0.0193 (N-2)*0.0193 (N-2)*0.0475 (N-2)*0.0475 (N-2)*0.0475 (N-2)*0.0950 (N-2)*0.0950 (N-2)*0.0950 0.009 0.009 0.009 0.03 0.03 0.03 0.071 0.071 0.071 0.156 0.156 0.156 (N-1)*0.009 (N-1)*0.009 (N-5)*0.009 (N-1)*0.030 (N-1)*0.030 (N-1)*0.030 (N-1)*0.071 (N-1)*0.071 (N-1)*0.071 (N-1)*0.156 (N-1)*0.156 (N-1)*0.156 70/30 100/30 140/30 70/30 100/30 140/30 70/30 100/30 140/30 70/30 100/30 140/30 100/43 143/43 200/43 100/43 143/43 200/43 100/43 143/43 200/43 100/43 143/43 200/43 200 *Kaori reserves the right to make changes without prior notice.

CO 2 Refrigeration System Subcritical Cascade system Cascade refrigeration system is a good solution for low-temperature refrigeration system that can not be achieved by single-stage refrigeration systems, enabling optimum compressor efficiency, and reduce compressor exhaust temperature and its compression ratio. In the cascade refrigeration system, the system of HFC refrigerant is applied to the main circuit (mid-high temperature), and R744 (CO 2) refrigeration system is applied to the low temperature overlay circuit, two individual circuits exchange heat through a cascade heat exchanger. Furthermore, (suction line heat exchanger) are commonly designed in R744 (CO 2) refrigeration system, which increases subcooling and superheating of R744(CO 2), improve the efficiency of evaporator, and reduce the risk of compressor failure (refrigerant will be completely evaporated before entering refrigerant compressor). KAORI C series high pressure BPHE is the best solution for such a system design, with the advantage of high heat transfer, compact size, and light weight. *KAORI K Series and R Series standard plate heat exchangers could be applied as economizer,, and heat recovery BPHE of the HFC refrigerant system. Heat Recovery Oil Separator Evaporative Condenser Oil Separator High Pressure HFC Gas High Pressure HFC Liquid Low Pressure HFC Gas High Pressure R744 Gas(Subcritical) High Pressure R744 Liquid(Subcritical) Low Pressure R744 Gas(Subcritical) Condenser Receiver Receiver HFC Cycle CO 2 Cycle Model Selection Chart for Evaporative Condenser Model C095-70 C095-100 C200M-50 C200M-60 C200M-70 Capacity kw 30 40 50 60 70 Primary Side Pressure (bar) Evaporation Temp. R744 R404A 30-20 (CO 2) 70 Secondary Side Pressure (bar) Condensation Temp. -10 *Suction line heat exchanger could be designed according to different working conditions. *Kaori reserves the right to make changes without prior notice.

Subcritical Secondary Coolant System Usually, secondary coolant system uses brine circulation system as the refrigeration medium, but through the high density characteristic of liquid CO 2, and its better thermodynamic property during medium temperature refrigeration process, R744 (CO 2) is very suitable for replacing the original E.G, P.G secondary refrigerant. This refrigeration system first works with HFC refrigerant compressor to start cooling process, and through evaporator, it cools down (condense) R744 (CO 2) on the secondary side, then a pump will distribute low temperature R744 (CO 2) through whole system. KAORI C series is suitable to be the evaporator of this system, in addition of increasing thermal conductivity, KAORI C series are also smaller model size, and higher and safer pressure resistance. To satisfy customers in different industries, KAORI provides various kinds of connectors for customization, at a reasonable price which benefits customers to attain lower assembling costs. Heat Recovery Oil Separator Evaporative Condenser High Pressure HFC Gas High Pressure HFC Liquid Low Pressure HFC Gas R744 Liquid(Subcritical) R744 Gas(Subcritical) Condenser Receiver CO2 Tank Pump HFC Cycle CO 2 Cycle Transcritical Booster System Two stage compression system pertains to a single R744 (CO 2) circuit, by connection two R744 (CO 2) compressor in series, provide mid-temperature and low temperature refrigeration applications in a single system, and includes tanscritical, subcritical, and supercritical characteristics of R744 (CO 2). KAORI C series high pressure heat exchanger could be used/installed for several different applications, such as gas cooler, economizer, (suction line heat exchanger) and intercooler, KAORI C series is the best solution for R744 (CO 2) applications. Heat Recovery Oil Separator MT LT High Pressure R744 Gas(Supercritical) High Pressure R744 Liquid(Subcritical) Low Pressure R744 Gas(Subcritical) High Pressure R744 Gas(Subcritical) Low Pressure R744 Gas(Subcritical) TC SC Condenser TC SC TC Bypass Valve SC Pressure Control Valve Flash Tank TC: Transcritical SC: Subcritical

Transcritical CO 2 Heat Pump System CO 2 heating system, as known as CO 2 heat pump system, could be divided into two categories, air and water source heat pump. Both has mainly the same concept, but different heat sources. Air source heat pump is very suitable in the frigid zones, with high COP (Coefficient of performance) efficiency for hot consumption water or bath water applications. KAORI C series plate heat exchanger could be used as the gas-cooler in heat pump system, in this system, water could be heated up to maximum 90 C, at this temperature, it is also suitable for cleaning and other industrial process applications. 3 Way Valve Cold Water Hot Water High Pressure R744 Gas High Pressure R744 Liquid Low Pressure R744 Gas Low Pressure R744 Gas Tank Gas Cooler Pump 3 Way Valve Receiver Model Selection Chart for Suction Line Heat Exchanger() Model C022M-14 C022M-18 C022M-22 C022M-48 C097-26 C097-30 Capacity kw 0.5 1 1.5 3 8 10 R744 (CO 2) Primary Side Working Inlet Temp. Outlet Temp. 140 100 25 16 R744 (CO 2) Secondary Side Working Inlet Temp. Outlet Temp. 70 19-20 0 Model Selection Chart for Gas Cooler Model C022HP3-28 C022HP3-40 C022HP3-58 C042P2-60 C097P3-102 C202HP2-48 Capacity kw 5 10 15 30 80 100 R744 (CO 2) Primary Side Working Inlet Temp. Outlet Temp. Secondary Side Flow Rate (L/H) Inlet Temp. Outlet Temp. 140 100 90 25 Water 70 90 179 269 538 1433 1792 17 65 *Kaori reserves the right to make changes without prior notice.

Supercritical CO 2 Extraction The extraction technology in food and pharmaceutical industries are commonly using organic solvent as the extraction agent. But in recent years, many advanced technologies have begun to replace organic solvent with supercritical R744, due to the higher solubility and higher permeability, R744 critical temperature is closer to the ambient temperature (31.7 C), and rare chemical reaction with the extraction substances. With all the above mentioned advantages, supercritical CO2 is one of the most important developments in many industries and countries. KAORI latest high pressure C series plate heat exchanger is the best solution for supercritical extraction, as a gas-cooler or sub-cooler. Comparing to traditional heat exchangers, KAORI C series has smaller model size, higher heat transfer performance, and easier installation. Hence KAORI C series is chosen by manufacturers of CO 2 Extraction technology system. Extraction Valve Separation Valve Water Out Water In CO2 In High Pressure R744 Liquid High Pressure R744 Gas High Pressure R744 Liquid CO2 Cooler Liquid CO2 Extractor Separator Cooling Source CO2 Tank Extracts CO2 Cooler High Pressure Pump Water In Water Out Automobile CO 2 Air Conditioning System Due to the phenomenon of global warming, and flammable characteristics of HFO refrigerants, for the environment and for driving safety, HFO-1234yf has been banned in most of European countries. To find an alternative and environmentally friendly medium, many car dealers are gradually introducing R744 (CO 2) into their new vehicle air conditioning system for replacing HFO. Non-flammable characteristics, with only 1 GWP value, R744 (CO 2) is more environmentally friendly and a safer refrigerant for vehicle air conditioning system. KAORI C series plate heat exchangers are dedicated for R744 (CO 2) applications. C series working pressure could be customized up to max. 140 bar, with advantages of high thermal efficiency, and compact and lighter model, it is truly the best component for vehicle CO 2 refrigeration system. Interior Heat Exchanger Low Pressure R744 Gas High Pressure R744 Gas Low Pressure R744 Liquid Low Pressure R744 Gas Coolant Gas Cooler Pump External Heat Exchanger

Professionals in Customized Heat Exchangers HEAD OFFICE 5-2, Chilin North Road, Chung-Li Industrial Zone, Chung-Li District, Taoyuan City, Taiwan TEL: +886-3-4626958 FAX: +886-3-4628021 E-Mail: sales@kaori.com.tw KAORI reserves the right to make changes without prior notice. 2017.09/1,000 www.kaori-bphe.com