Installation. Please keep this manual for future reference.

Similar documents
SUPPLEMENTARY INSTRUCTIONS

STOP. For missing, damaged parts or technical help, Call before returning product

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Owner s Manual WARNING! Congratulations

Gen II Entree Bath - All Models

NOTICE TO INSTALLER: Instructions must remain with installation. 95 North Oak Street Kendallville, IN

#PSBTWE1000 INSTALLATION GUIDE

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Installation Instructions Built-In Dishwasher

Installation Instructions

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

Installation Instructions

Top Control Dishwasher

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization

Installation Instructions

1-866-PENNERS

3/4.8 AERODYNE 3/4.8L CLASS FIVE+

Installation Instructions

Downdraft Ventilation

Dishwasher Installation Instructions DW 24XT/DW 24XV

INSTALLATION INSTRUCTIONS TD75. Vented tumble dryer DOMESTIC. Carefully read the instructions for use before using the dryer.

IB 835. Installation Manual. Integrated Bidet Toilet TABLE OF CONTENTS

Installation Instructions Built-In Dishwasher

Aqua-Aire Sit-Bath System 6300 Installation / Assembly Instructions

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP

Features Luxier SP21-SS

SAVE THESE INSTRUCTIONS

BURWELL BIDET TOILET SEAT INSTALLATION

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

RESIN FREESTANDING TUB

WARRANTY POLICY & RECOMMENDED MAINTENANCE

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

Installation instructions for vented tumble dryer DOMESTIC. Dear Customer,

PolyMax H2-24 Dutch Bucket System

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR- DWSH01- S

Features Decor Star PL-004-SS

MODEL INSTALLATION INSTRUCTIONS SEWAGE PUMP

LC Series - Light Commercial Pump Station Installation and Operation Manual

Features Decor Star PL-004-SS

MODEL INSTALLATION INSTRUCTIONS GRINDER PUMP

SolidFlo G2 Solid Handling Pumps Product Manual

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

KD-27A SERIES DISHWASHERS

MODEL E

Installation Manual PS-225 & PS-275

Features Luxier SP26-GS

Food Waste Disposer Instruction Manual

PL-004-SS. * Proper water pressure is required for simultaneous operations

Pool Power Pak. III with On/Off Switch UL Models (1 HP), (1-1/2 HP) NEC Models (1 HP), (1-1/2 HP)

Concepts Serving Systems

COPPER FREESTANDING TUB

Features Luxier SP21-SS

Energy-Free Waterers SF-2C, SF-4C, EF-2C, EF-4C

HydroCycle Vertical Aeroponic Systems

INSTALLATION INSTRUCTIONS

RELAX. REVITALIZE. RESTORE. LUXURY SPA UNIT Installation Manual. English. For Model Numbers 2848, 2853, 3153 and 3255

Clean Water Made Easy

HydroCycle Vertical Aeroponic Systems

Installation Instructions

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Factory Direct Walk-In Tubs WALK-IN TUB. Installation Manual. For Model Numbers VT2848, VT2853, VT3153 and VT3255

ANTARES ORDERING INFORMATION NOTES T01-G INSTALLATION INSTRUCTIONS

HD-26, HD-36, HD-48 Heated Displays

MIRAGE EVO 250 PEDICURE SYSTEM

FRESH HEAD. MANUAL TOILET for pressurized fresh water rinse INSTALLATION AND MAINTENANCE INSTRUCTIONS

Clean Water Made Easy

HYDROMATIC. JB-1 System Sewage Ejector Pump Package. Pump Installation and Service Manual

Handshower, Hose & Handshower Accessories

Decor Star 1. Decor Star PL-037-SS

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

500 Series Toilets. Model 111 Toilet. Table of contents. Specifications. Gravity-Discharge Toilet Operation manual

Installation Instructions

Installation Instructions PRO SERIES

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Installation Manual PS-200 & PS-201

Ebb & Flow System

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

Portable Dehumidifier

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR-DWSH01-S

DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

INSTALLATION INSTRUCTIONS

Oahu Showerspa Model #1035 Owner's Manual

Installation Instructions

Welcome! Today s topic: Small Home Repairs. November 14, 2015

Models: RP-10, RP-15, RP-20. User Manual

THE BEAUTY OF WATER THE SCIENCE OF RENEWAL. Heating Circulation System. Installation Instruction Manual

INSTALLATION, OPERATION AND MAINTENANCE

Installation Instructions

TFC 400. OPERATOR MANUAL Clarke MODEL /09 Rev C Document Number

Media Service Instructions 1500 Series BAT Media Plants

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Dishwasher Installation Manual

Macerator Pumps & Lifting Station. Technical presentation Part 1

WATERGENIE. Install a Toilet or Bathroom anywhere you like Installation and Maintenance Instructions

Transcription:

Installation Tecma Bathroom Anywhere Owner s and Installation Manual Please keep this manual for future reference. Read ALL these instructions before installing the Tecma Bathroom Anywhere unit. Warning Read and understand the warnings listed in this document before you install, operate, or service this system. If you do not obey these warnings there is a risk of property loss, injury, or electrocution. Do not make any changes to this unit as this could result in property damage, injury, or electrocution. Thetford Corporation accepts no responsibility or liability for damage to equipment, injury, or death that may result from the system's improper installation, service, or operation. Thetford Corporation recommends that plumbing and electrical work be performed by a licensed tradesperson. Local permit and code compliance is required. Caution: To avoid damaging property and to make sure the unit operates correctly, please do the following: Do not flush anything other than human organic waste and toilet tissue. Do not fl ush paper towels, pre-moistened wipes, condoms, feminine hygiene products, dental fl oss or household garbage. Do not allow the Bathroom Anywhere system to freeze. See Winterization. Make sure that any pipe work that may be exposed to freezing temperatures is insulated. Make sure that plumbing fi xtures attached to the pump do not leak. If there is a power failure the pump will not operate, and this could cause the unit to overfl ow and fl ood. CAUTION: Do NOT use one-way air admittance valves (also known as cheater vents). Macerating pumps need two-way air movement. Electrical Cautions: To ensure safe operation: The pump must be connected to a properly grounded (GFCI - ground fault circuit interrupter) receptacle on a dedicated 5 AMP circuit. Do not use in swimming pool or marine areas. Always disconnect the plug from the power source before servicing or handling the pump. Do not use an extension cord with this unit Do not make any modifi cations to, or remove the ground pin from, the pump's power supply cord plug. Warranty Refer to the one-page warranty statement. Record your product information. Keep for future reference. Refer to Fig. B. Required Tools Pipe saw Phillips screw driver Flathead screw driver 5/6" Socket wrench Hammer Level Tape Measure Drill /" masonry drill bit (Concrete fl oors) /4" drill bit (Wood fl oors) Materials Not Provided PVC/ABS primer and cement -/4",-/", and " rigid (Schedule 40) pipe fittings, as needed 3" pipe extension and 3" coupler (depends on installation) Tee-wye sewer connection Ball valves sized to inlet and discharge pipe sizes " Sewage pump check valve (depends on installation) For optimal performance, use long sweep 90 angles. Refer to Fig. A. Fig. A Standard Elbow *Long Sweep *Two connected 45 angles can be substituted for one long sweep Product Information Fig. B Serial Number Location of Serial Number PRODUCT INFORMATION Register this product at www.bathroomanywhere.com ART0080--3 ART0004 Date of Purchase: Model Serial #: www.bathroomanywhere.com Form No. 3879 Rev. D 09//0

Parts Included with Pump # Pump Fig. C (3x) 3-50mm # (3x) 90-0mm #3 (x) 60-70mm #4 (x) " #5 ART009 (x) -/" #6 (x) #7 (x) #8 (8x) #9 (x) #0 (x) # (x) # (x) #3 Circuit Protection Overheat Protection Manual Switch Parts Included with Thetford Toilet NOTE: Parts shown below are referenced in the instructions and apply to Thetford's rear discharge toilet and water tank. Your instructions may vary if you are installing a different rear discharge toilet. Plumbing Purchased Separately NOTE: Plumbing components pictured below are referenced in the installation instructions. Additional plumbing components are required based on your site. (x) #4 (x) #5 (x) #6 ART009 #0 Water Tank ART0093--4 -/4" Long P Sweep Elbow to install Discharge -/" 90 o P5 Street Elbow to install Vent (x) (x) #7 (x) #8 #9 # Rear Discharge Toilet -/" 90 o Street Elbow to install Sink P " 90 o P3 Street Elbow to install Shower/Tub Ball Valve P6 P7 Sewage Pump Check Valve (Flapper Type) Fig. D -/" Elbow to install Vent P4 Fig. E P8 3" Coupler for 3" Extension Pipe ART009--7

NSF C US ASME A.3.4 CSA B45.9 Power supply Power Current 8.0A Circuit Requirement Dedicated 5 AMP Technical Specifications The system has the NSF C-US certification. The National Sanitation Foundation (NSF) has tested and certified this system to be compliant with the ASME A9..3 and B45. standards for household macerating systems for the United States and Canada. This NSF certification ensures U.L. electrical compliance to U.L. 778 Standard. 0 V 600 W Frequency Duty cycle 60 Hz.5 gpm, 0 foot lift, hour on; 45 minutes off Terms & Dimensions Fig. F F G H D I E J K Serial Number 8 5/8" 7 /4'" 9" including Inlet Bladder 3/8" Tall Feet " Short Feet B C A ART0004 A. B. C. D. E. F. Rubber Feet Side Cover Toilet Inlet -/" Vent Opening Knob to Separate Pump Circuit Protection G. H. I. J. K. Thermal Protection Manual Switch -/4" Discharge Outlet -/" Sink Inlet " Sink, Bathtub or Shower Inlet 3

Fig. G Planning the Installation Plumbing Considerations for Installation 3. The placement of the 0V GFCI outlet location MUST meet local code Recommend at least 40" away from bathtub or shower and within 6' of the pump.. -/4" discharge 3. -/" vent connected to outside-do NOT use one-way "cheater" vents 4 Ensure proper slope on all 4. horizontal runs 5. Water overfl ow drain -/" drain for bathtub; " drain 6. for shower 7. Platform - refer to Fig. J Ball valve recommended for 8. pump discharge 9. -/" Drain Optional ball valves for pump 0. inlets " sewage pump fl apper check. valve Tee-wye sewer/septic line. connection 5 8 7 0 GFCI 9 6 0 ART0043 All plumbing fi xtures attached to the pump must be located on the same fl oor of the building. The pump will pump up to 8' vertically or up to 50' horizontally with proper slope. If a vertical rise is required, it should come before any horizontal run to allow for proper operation. All inlets in the unit must be connected to a fi xture (toilet, sink, etc.) OR covered with the plugs provided Do not use any plumbing fi xtures (sink, toilet, etc.) until the pump is installed and tested. Be sure the fi xtures do not leak as this will cause the pump to continually operate, causing excessive wear on the pump Shower/tub must be elevated to ensure proper drainage. Refer to Fig. J. CAUTION: Make sure all local plumbing and electrical codes are followed when installing the Tecma Bathroom Anywhere pump. To ensure effi cient waste evacuation, the pump must have at least 3' of -/4" discharge pipe before transitioning to a larger pipe size. All pipes must be constructed of rigid material, such as PVC. Do NOT use fl exible pipes. All fi ttings should be primed and glued. Do NOT glue pipe to rubber tank; use clamps provided. Installing ball valves near the inlets and discharge pipe will make it easier to remove the unit for maintenance. Select the right option for your installation. Plan GFCI electrical location and placement of all fi xtures before you begin the installation. Plan for maintenance accessibility. As you plan your installation, consider the accessibility to the air vent and water supply. 4

Which Installation Best Fits My Site? There are three basic installation options. When planning the installation, note overall width of toilet and offset placement of pump; plan for maintenance accessibility INSTALLATION OPTION #: Pump and Plumbing Behind Wall - you need a 3" rigid pipe and 3" pipe coupler (not included), and shorter foot pads (included) to achieve the proper drainage slope. Distance between toilet outlet and pump inlet can not exceed 36". Allow additional space for side-to-side maintenance access. OPTION # 7.75 Fig. H 6.00 ART008-3" Rigid Pipe Not to exceed 36" OPTION # ART008- INSTALLATION OPTION #: Pump Exposed and Plumbing in Wall - place the pump in front of the wall with the plumbing in the wall. Allow additional space for side-to-side maintenance access. 0.00 34.00 OPTION #3 ART008-3 INSTALLATION OPTION #3: Pump and Plumbing Exposed - place the pump and plumbing in front of the wall. Allow additional space for sideto-side maintenance access. 0.00 37.75 5

Install Toilet and Pump NOTE: Unless otherwise noted, steps apply to ALL installation options. Site Preparation Complete the following before starting the installation: Installation site fl oor fi nished and level within /8". Place all components in the desired installation position; mark footprint and bolt positions. Check for all clearances including doors and cabinets. Also be sure to check for vertical clearance for any shower enclosure. Refer to Fig. G and H. Ensure that all plumbing and electrical do not interfere with placement of bathroom fi xtures. Rough plumbing and electrical are completed to code. The placement of the 0V GFCI outlet MUST meet local code Recommend at least 40" away from bathtub or shower and within 6' of the pump. Warning Do not use an extension cord as this is a safety hazard that can cause injury Drill fl oor holes for toilet. If installing in concrete fl oor, install anchors but do NOT permanently secure fi xtures until instructed. Refer to Fig. I. ART0090- ART0090- Using Anchors: drill holes using a /" masonry drill bit; then insert Part #8. Using Only Screws: drill pilot holes using a /4" drill bit Concrete Floor Installation #8 Wood Floor Installation CAUTION: To permit proper drainage it is essential to elevate the shower/tub drain to a MINIMUM of 9" above the fi nished fl oor of the installed pump. If necessary, remember to adjust the height of the shower/tub drain upwards to allow proper grade for the plumbing connection to the PUMP. Plan accordingly; refer to Fig. J. Fig. I Shower or Tub Floor Height Drain opening of shower or tub IMPORTANT: BE SURE the fl apper swings freely with minimum fl ow by installing as shown. P7 9" IMPORTANT: Top of drain opening MUST be elevated AT LEAST 9" above the fi nished fl oor of the installed pump. ART0094- Fig. J 6

Install Toilet and Pump, Con't. Step. Attach Connections Insert the plumbing connections according to your installation plans. Refer to Fig. C, E, and F. Shower/Tub Sink CAUTION: Do NOT insert plumbing more than " deep into plumbing openings. CAUTION: Do NOT glue rigid plumbing to rubber inlet. Use the provided clamps J # K #4 P3 -/" P " ART0088- ART0088- Discharge Vent Line # P -/4" 34.00 0.00 Pipe MUST be offset " from discharge pipe For maintenance purposes, leave at least -/" of straight plumbing above # clamp. D Slide over plumbing -/" #0 # ART0088-3 ART0089- Installations with Unused Inlets If J and K are not attached to a fitting, they MUST be covered with the caps using clamps provided. Installations without Toilet If C is not attached to a toilet, it MUST be covered with the cap using clamp provided. #6 J -/" C #5 K " #3 #7 ART0009 ART00088 I ART008- # #4 7

Install Toilet and Pump, Con't. Step. Attach Labels Fig. K # Circuit Protection Overheat Protection Manual Switch ART0086- Step 4. Connect Vent to Vent Stack CAUTION: Do NOT use one-way air admittance valves (also known as cheater vents). Macerating pumps need two-way air movement. CAUTION: The pump must be vented to the outdoors, per your local plumbing code.. Measure rigid pipe from vent on pump to vent connection (new or existing vent stack). Place label based on installation visibility. Connect rigid pipe to main vent stack of house or directly outdoors. Step 5. Connect Discharge Line Place label near toilet #3 ART0086- CAUTION: Pump discharge outlet has a built-in check valve. Do NOT install an additional check valve as this may cause the pump to malfunction.. Install -/4" ball valve approximately 6" from pump discharge outlet. Plan for accessibility.. Install -/4" plumbing line to house main waste line. There must be at least 3' of run from the pump before connecting to main waste line. CAUTION: To verify proper lengths for plumbing, be sure to dry-fi t ALL plumbing BEFORE permanently bonding plumbing connections Place the pump in the installation position and follow the steps below. Note: When connecting to the sewer line, use directional fi ttings that meet your local plumbing code. Refer to Fig. G for Steps 3-5. Step 3. Connect Bath/Shower/Sink CAUTION: Make sure there is proper slope of all horizontal runs ATTACH BATH / SHOWER To permit proper drainage it is essential to elevate the shower/tub drain to a MINIMUM of 9" above the fi nished fl oor of the installed pump. If necessary, remember to adjust the height of the shower/tub drain upwards to allow proper grade for the plumbing connection to the PUMP. Refer to Fig. J. If bathtub is connected, the " connection can be reduced to -/" with adequate slope into the pump... 3. Measure rigid pipe from " pump inlet to shower/bath drain. Cut pipe to fi t. Connect shower/tub to " inlet with proper slope. ATTACH SINK. Measure rigid pipe from sink drain to -/" pump inlet.. Cut pipe to fi t. 8

Install Toilet and Pump, Con't. Option Only Step 6. Connect Toilet and Pump IMPORTANT: Be sure the fl oor holes are drilled before you begin the following steps ART0096 ART0087-3 ART0087--3 #8 Replace (8X) Remove tall feet (8X) #9 #3 HINT: Sit on the toilet to attach #8 Apply soapy-water for lubrication; use non-petroleum-based products only 4 ART0087-4 Top of fi nished fl oor Drill wall hole. Wall hole center must be located and sized to accommodate pipe slope. 5 Cannot exceed 36" P8 ART0087-6 Position #3. Then apply soapy water to lubricate & position #8 ; use nonpetroleum-based products only Be sure that #8 covers at least -/" of toilet outlet. 6 ART0087-5 #3 3" Rigid Pipe #8 P8 C Option & 3 Only Cut pipe to fit; cannot exceed 36" Bond P8 to pipe end that will be connected to pump. Step 6. Connect Toilet and Pump IMPORTANT: Be sure the fl oor holes are drilled before you begin the following steps 3 ART0095- ART0095- Insert pipe through wall; connect ends. #8 must cover at least -/" of pipe. C must cover at least -/" of P8. HINT: Sit on the toilet to attach C ART0095-3 #3 C #3 Apply soapy water for lubrication; use C must cover at least -/" toilet outlet; non-petroleum-based products only tighten #3. 9

Install Toilet and Pump, Con't. Step 7. Assemble & Secure Toilet NOTE: Instructions apply to Thetford Rear Discharge Toilet. Assemble water tank; follow the instruction sheet supplied with Thetford tank BEFORE you begin the steps below. Level the toilet ART0083- #0 3 #0 #7 #9 (x) (x) #6 #8 (Already installed in concrete) ART0083- # # ART0083-3 NOTE: Recommend that a bead of caulk is applied around base of # 4 Verify proper placement of hose 5 Position as shown #5 6 #4 # ART0066 ART0084- #5 ART0083-4 Offset bolts allow for proper alignment of seat cover on bowl. Slide to adjust to toilet. Secure by hand-tightening #5. Step 8. Prep and Test the System.. 3. 4. 5. 6. Finish connecting all fi ttings and fi xtures. Open water supply valve to toilet and/or fi xtures. Check for leaks; correct as needed. Plug pump into wall outlet. Flush toilet. NOTE: If pump initially runs more than 0 seconds, follow the "Prime the Pump" directions. Check for leaks; tighten and adjust clamps and connections as needed. 0

System Operation What to Expect This toilet operates on a different principle than a typical siphon toilet resulting in a different sound and fl ush action. When activated, the pump pulses a few times. Water spot in toilet bowl is different than the water spot in a siphon toilet. Cleaning Use only non-abrasive, non-petroleum products to clean the pump. Circuit Protection Refer to Fig. L item F. The circuit breaker prevents the pump from operating if the pump becomes jammed by foreign objects. After the obstruction is removed, press the circuit breaker button to reset the pump for operation. Thermal Protection Refer to Fig. L item G. If the system overheats, a light comes on indicating that the system is unavailable for use. Once the system cools to an acceptable temperature level, the light will turn off indicating that the system is reset and ready for use. Prime the Pump If pump initially runs more than 0 seconds, prime the pump as follows: a. Unplug cord from wall outlet. b. Wait 5 seconds. Plug cord back into wall outlet. c. Flush again. If pump runs more than 0 seconds, repeat Steps A-C. Clearing the Pump of Debris F G Winterization H Fig. L Bathroom Anywhere systems exposed to freezing temperatures require winterization. All fixtures, inlet and discharge lines depicted in Fig. G must be winterized using non-toxic propylene glycol (RV Marine Antifreeze). Use sufficient quantity of antifreeze to ensure all pipes are protected Steps: Shut off water supply. Flush toilet to empty tank. Pour RV/ Marine antifreeze into toilet and all fixtures. Press manual switch H to run antifreeze through system. ART00089 It may be possible to clear the pump of debris using the following steps. Do NOT use a plunger 3 B # E TOWEL TOWEL ART0097 ART00089 4. Remove # plug.. Quickly insert # bag. 3. Drain excess liquid into bag; re-insert # plug. Turn E counter-clockwise until unit separates. 6 ART00090- ART00094 ART00095 Unplug the pump. Close discharge pipe ball valve; refer to Fig. G position 8.. Unplug pump from wall outlet. 3. Remove B ; place towel. 5 ART00090- Use tool to clear debris. Reconnect unit; turn E Verify that o-rings are positioned securely clock-wise to in groove re-connect. 7. Open discharge pipe ball-valve. Follow the "Prime the Pump" directions until the pump engages. Due to back pressure 8. Plug in unit. in the discharge line, this may require more than one attempt depending on system 3. Flush toilet to test. configuration.

Service Kits Fig. M 3 5 A-B 9 4 6 0 3 8 7 ART000 No. Part No. Description 38705 Bathroom Anywhere Toilet Inlet Side 38706 Bathroom Anywhere Pump Side w/pump 3 38707 Bathroom Anywhere Toilet Inlet Cap 4 38708 Bathroom Anywhere Vent Shroud 5A 38709 White Elongated Slow Close Seat and Lid 5B 3870 Bone Elongated Slow Close Seat and Lid 6 387 Toilet Seat Bolts () Offset Bolts For Bathroom Anywhere Elongated Seat 7 387 Bathroom Anywhere Floor Mounting Anchors and Bolts Package 8 3873 Bathroom Anywhere Drainage Bag 9 3874 L Shaped Cover 0 3875 Extension Bellows 3876 Rubber Feet (4 Tall, 4 Short) 38744 Pressure Switch 3 38745 O-Rings and Bushings Questions? -800-543-9 See your dealer for more information about Thetford products. Or, write or call: www.bathroomanywhere.com Thetford Corporation P.O. Box 85 Ann Arbor, MI 4806-800-543-9 Form No. 3879 Rev. D 09//0