GOODBYE SQUARE AIR SAMSUNG AIR CONDITIONING. VRF SPECIFIERS DESIGN GUIDE 4 th EDITION

Similar documents
Learn more about Samsung air conditioner at:

DVM S Digital Variable Multi Smart VRF SPECIFIERS DESIGN GUIDE

Samsung Air Conditioning CASSETTE SPLIT SYSTEM AIR CONDITIONING. Samsung Air Conditioning 1

Samsung EHS, XL Range of Commercial Air to water heat pumps

PAC (FLOOR STANDING) 2016 Samsung

Samsung Air Conditioning SURFACE MOUNTED SPLIT SYSTEM AIR CONDITIONING. Samsung Surface Mounted A/C TO PRINT.indd 1 07/10/ :25

A single answer for multiple zones.

A single answer for multiple zones.

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.

Samsung 360 Cassette, Single Zone, Split System

2008 SAMSUNG SYSTEM AIR CONDITIONERS Version.2

Increase your flexibility.

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply

Samsung System Air Conditioner CAC and FJM

The ultimate fresh air solution.

Only properly trained, HVAC professionals should attempt to install and start up any Samsung heating and airconditioning

SAMSUNG SPLIT AIR CONDITIONER MAX PLUS

FREE JOINT MULTI. Multi-Zone Mini Split Air Conditioner. Ver quietside.com

Product Line Introduction. Karl Zhang Technical support engineer

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

Product Brochure Smart Power. Low Profile Ducted

Business. The business range. The most advanced solutions for larger buildings.

SINGLE. Technical Data Book. PAC for Europe (R410A, 50Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

SAMSUNG DVM Air Conditioner. Accessories. DVM PLUS III HP/HR North America for 60Hz

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

SAC Technical Data Book

SINGLE Technical Data Book SINGLE Duct S for America (R410A, HP)

Product Brochure 2017

Residential and Light Commercial Ductless Systems Catalog

Heat Pump Air Conditioning Systems

LG HVAC SOLUTION. LG Electronics Distributed by. Copyright 2016 LG Electronics. All rights reserved.

Samsung Free Joint Multi Air Conditioning System

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

Air Conditioning System

4. VRF - Digital Variable Multi (DVM) 226. Introduction Residential - Room Air Conditioner (RAC) Multi Split - Free Joint Multi (FJM) 56

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

DC Inverter Smart VRF Products(R410A)

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

LG AIR CONDITIONERS Ducted Split System. Quiet & Comfortable with LG HVAC.

Concealed ceiling unit with medium ESP

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE

VRV IV i-series heat pump

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

Submitted to Reference Approval Construction Unit Designation Schedule #

Submitted to Reference Approval Construction Unit Designation Schedule #

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

Modular Air Cooled Scroll Chillers

SMC DUCTED. High Performance AIR CONDITIONING SYSTEMS

Inverter console UFV system. Compact design and personalised air flow selection

Main Feature. Silent Mode Indoor units operate quietly with the least possible noise.

Inventor of the Inverter Digital Inverter System

3 rd Generation of VRV. The professional solution for your professional project

(Non-Inverter & Inverter) R410A

Keep looking you ll never find me. VRV IV heat pumps for indoor installation

DVM S Universal Communication Kit (UCK) Design Guide

Ducted Air Conditioning

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

Blending Commercial and Residential. MiNi VRF

FREE MULTI SYSTEM Z R32 GAS. NEW FREE MULTI SYSTEM Z Up to 5 indoor units with a single outdoor unit R32 NEW REFRIGERANT GAS

LG VRF Systems. Air Conditioning Technologies

Single Fan MiNi VRF Apartment Ready

Just feel well. 2017/2018 Air conditioning

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

Concealed ceiling units

NEW FREE MULTI SYSTEM E Up to 5 indoor units with a single outdoor unit FREE MULTI SYSTEM E R410A GAS

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Ducted Air Conditioning

Energy-saving operation

Comfort. Health Clean. Saving. The new era in air conditioning. Multi-Split Systems

Do you want a versatile solution

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

VRV IV S-series heat pump

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

Geniuses at work. Residential Mini Splits

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

Samsung Air Conditioning

Light commercial range. Passion at work

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw

AIR CONDITIONING REVERSE-CYCLE INVERTER

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Comfort. Health Clean. Saving. The new era in air conditioning. Multi-Split Systems

Integrated VarIable refrigerant flow ahu/pau (r410a)

Transcription:

GOODBYE SQUARE AIR SAMSUNG AIR CONDITIONING VRF SPECIFIERS DESIGN GUIDE 4 th EDITION 1 www.samsung.com/uk/dvms

Samsung is moving with, and ahead of, our customers Put simply, our differentiation is centered on producing innovative technology that brings genuine change to people s lives. We do this by bringing a relentless focus on consumer experience and product innovation to everything we do. Sue Shim CMO (Chief Marketing Officer), Samsung 2009 Best Global Brand Rank. 19 17,518 $m 2008 Best Global Brand Rank. 21 17,689 $m 2010 Best Global Brand Rank. 19 19,491 $m Why Samsung? As one of the world s largest technology companies, Samsung are delivering a complete and connected set of products and solutions for commercial properties and enterprises. Samsung will work with you to provide your customers with leading edge total building propositions utilising the latest innovative technologies. Hotel TV solutions Professional displays Smart signage Security systems Mobile devices and apps Printing solutions Telephone systems Wireless networks Air conditioning 02 www.samsung.com/uk/dvms

Introduction Samsung have been manufacturing air conditioning systems for over 40 years, utilising the latest technology and striving to produce the most innovative, efficient and reliable systems on the market today. The 5th generation Samsung VRF systems deliver leading efficiencies, long pipe runs and smart controls to provide air conditioning solutions for a variety of commercial applications. Continuous Samsung innovation has created the largest single VRF outdoor, a compact modular chiller and the worlds first circular cassette. This guide has been produced to assist in the selection of the most suitable equipment for today s commercial projects, from Samsung s comprehensive portfolio of 2 and 3-pipe air and water cooled systems, extensive range of indoor unit designs and variety of control options. Samsung air conditioning has already been specified and installed in a wide range of UK properties and applications in conjunction with other products from the Samsung Electronics product portfolio, including hotel TVs, display screens, CCTV, security systems, wireless networks, mobile devices and Smart Home (internet of things). Samsung Air Conditioning 03

Nomenclature Outdoor units 1 Classification AM DVM AM 080 K X V A G H 2 Capacity x 1/10 HP (3 digits) F 2013 1 2 3 4 5 6 7 8 3 Version H/J 2015 K 2016 4 Product Type X Outdoor Unit V DVM S 5 Product Notation W DVM S Water M DVM S Eco 6 Product Type A Stsndard H High Efficiency 7 Rating Voltage E G/N 1Ø, 220~240V, 50Hz 3Ø, 380~415V, 50Hz 8 Mode H R Heat Pump Heat Recovery Indoor units 1 AM DVM 2 Capacity x 1/10 HP (3 digits) AM 1 045 2 F 3 N 4 4 5 D E 6 3 Version F 2013 G/H 2014 J 2015 K 2016 4 Product Type N Indoor Unit "1" 1 way cassette "2" 2 way cassette 4 360 & 4 way cassette N Mini 4 way cassette L LSP Duct (Slim Duct) M MSP Duct 5 Product Notation H C HSP Duct Ceiling J Console F Floor Standing Q Neo Forte (EEV) V Wall A3050 (EEV) B Hydro Unit K ERV 6 Rating Voltage E/K 1Ø, 220~240V, 50Hz 04 www.samsung.com/uk/dvms

Contents Why Samsung is leading the way 06 Indoor Units 1Way Cassette 12 DVM Chiller VRF Chiller Hybrid 92 Outdoor Units Line-up Indoor Units and Controls Line-up 08 10 2Way Cassette 14 360 Cassette 16 4Way Cassette 20 Optional Accessories 23 Mini 4Way Cassette 24 Slim Duct 26 MSP Duct 30 MSP Duct S 34 Air Handling Unit (AHU) Kit 39 HSP Duct 40 Controls Controls Line-up 82 Individual Control 83 Centralised Control 84 Building Management 85 Power Monitoring 88 Gateways 89 Web Server 90 Console 42 Ceiling 44 Wall (Neo-Forte E) 46 Wall (A3050-E) 48 Floor 50 ERV Plus 52 Single Systems Air-to-Air Heat Exchangers 91 ERV Commercial Split Systems 94 CAC Hydro Unit 54 Mode Control Unit (MCU) 56 Commercial Split Systems 101 FJM Outdoor Units Outdoor Units Line-up 58 DVM S Heat Recovery 60 High Efficiency DVM S Heat 64 Pump Standard DVM S Heat Pump 66 High Efficiency DVM S Water 71 DVM S Eco 74 Piping Diagrams 78 Wiring Diagram 80 Samsung Air Conditioning 05

Why Samsung is leading the way High-pressure refrigerant discharge Class Leading Efficiencies (ESEER 8.00) The 3rd generation VRF system adopts a dual inverter compressor that upgrades refrigerant flow and the motor's operating performance. The new flash injection technology provides high heating performance at low temperatures achieving weather dependent efficiencies of up to 4.88 (EER) and 5.49 (COP). Flash Injection Technology Low-pressure refrigerant suction 30HP Single Outdoor Unit Available as Heat Pump 2pipe, the single outdoor unit provides 84kW cooling from a footprint of just 0.99m 2. A 22HP Heat Recovery unit is also available providing 61.6kW cooling. Piping Separation 200m The 200m piping separation between outdoor and indoor units, the height difference of 110m, and first branch to furthest indoor unit distance of up to 90m all lead the industry. (Please refer to the piping diagrams on page 78). 110m 200m Indoor Discharge Temperature Control Without changing the outdoor unit s setting, each ducted indoor unit or AHU kit has a discharge air temperature control function, offering greater comfort in cooling or heating mode. This is set by each MWR-WE10N remote control in a detailed setting mode and is only applicable to ALL ducted/ahu connected systems. Target Temperature Cooling: 11~18 degrees Heating: 30~43 degrees 50m** ** For heat pump system Programmable Mini BMS The DMS 2 web server incorporates programmable logic and ability to connect and control third-party equipment via 8 inputs and 6 outputs providing a mini-bms capability, plus Power Monitoring function, via associated interface. DMS 2 Anytime, Anywhere Control 06 www.samsung.com/uk/dvms

The World s First Circular Cassette Available for both VRF & Split systems, the stylish circular 360 cassette harmoniously blends into any type of interior design. The 360 degree rotational air flow delivers draught free even cooling throughout the space and the innovative bladeless air flow control adjusts the vertical direction of the air. 40kW Mini VRF The 14HP DVM S Eco has been innovatively packaged to provide 40kW cooling from a chassis 56% smaller than a conventional VRF and weighs just 162kg. Despite its size, efficiencies of 3.78 (EER) and 4.55 (COP) have been achieved. Smart Management Samsung provides an easy to use, smart management system that makes life simpler. With this web-based system, you can immediately access data and easily manage it for unsurpassed convenience. Auto Commissioning and Management (ACM) DVM S has a smart management system that facilitates self-diagnosis, auto commissioning, auto management, and mobile data transmission. Since you can control the system with smart phone or tablet PC, it provides easy and convenient management. Wi-Fi Monitoring System With S-Checker, DVM S can be monitored by smart devices such as smart phone or tablet PC. Samsung Air Conditioning 07

Outdoor Units Line-up DVM S 60. Heat Recovery 66. Heat Pump 64. Heat Pump Std 2-pipe Heat Pump (HP) or 3-pipe Heat Recovery (HR) Single Module HP 8 10 12 14 16 18 20 22 24 26 28 30 32 Cooling 22.4kW 28.0kW 33.6kW 40.0kW 45.0kW 50.4kW 56.0kW 61.6kW 67.2kW 73.6kW 78.6kW 84.0kW 89.6kW Max. kw Capacity 29.12 36.4 43.7 52.0 58.5 65.52 72.8 80.08 87.4 95.7 102.2 109.2 116.5 Model Capacity Max. no. Indoors 14 18 21 26 29 32 36 40 43 47 51 54 58 AM080JXVHGH/GR 8 HP 1 AM100JXVHGH/GR 10 HP 1 AM120JXVHGH/GR 12 HP 1 2 1 1 1 1 Outdoor Units AM140KXVGGH/ AM140JXVHGR AM160KXVGGH/ AM160JXVHGR AM180KXVGGH/ AM180JXVHGR AM200KXVGGH/ AM200JXVHGR AM220KXVGGH/ AM220JXVHGR 14 HP 1 1 16 HP 1 1 18 HP 1 1 20 HP 1 1 22 HP 1 AM240KXVGGH 24 HP 1 AM260KXVGGH 26 HP 1 AM280KXVGGH 28HP 1 AM300KXVAGH 30HP 1 Capacity HP 8 10 12 20 Outdoor Units 71. DVM S Water Phase Cooling 22.4kW 22.0kW 33.6kW 56.0kW Max. kw Capacity 29.12 36.4 43.7 72.8 Max. no. Indoors 14 18 21 36 3 Phase AM080FXWANR AM100FXWANR AM120FXWANR 3 Phase AM200FXWANR Capacity HP 4 5 6 8 10 12 14 Cooling 11.2kW 14.0kW 15.5kW 22.4kW 28kW 33.5kW 40kW Outdoor Units 74. DVM S Eco Phase Max. kw Capacity Max. no. Indoors 14.5 18.2 20.2 29.12 36.4kW 43.6kW 52kW 6 8 9 17 18 21 26 1 Phase AM040FMXDEH AM050FMXDEH AM060FMXDEH 3 Phase AM040FMXDGH AM050FMXDGH AM060FMXDGH AM080FMXDGH AM100KXMDGH AM120KXMDGH AM140KXMDGH 08 www.samsung.com/uk/dvms These products contain Fluorinated greenhouse gas R410A (GWP=2088).

Module Single Module 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 95.2kW 101.6kW 106.6kW 112.0kW 117.6kW 123.2kW 128.8kW 135.2kW 140.2kW 145.6kW 151.2kW 156.8kW 163.2kW 168.2kW 173.6kW 179.2kW 184.8kW 190.4kW 196.8kW 201.8kW 207.2kW 212.8kW 218.4kW 224.8kW 123.8 132.1 138.6 145.6 152.9 160.2 167.4 175.8 182.3 189.3 196.6 203.8 212.3 218.7 225.7 233 240.2 247.5 255.8 262.3 269.4 276.6 283.9 292.2 61 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 1 2 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 2 2 2 1 2 3 2 2 2 2 2 3 3 Please check manual for full list of outdoor combinations, including those using 24HP+ *Please check Eurovent website to confirm exact model certification. Selection steps Select Indoor Units 2-Pipe 3-Pipe Select Outdoor Unit type and size Confirm Piping Restrictions Select Controls MCU Configuration Samsung Air Conditioning 09

Indoor Units and Controls Line-up Type Capacity 1.5/1.7kW 2.2kW 2.8kW 3.6kW 4.5kW 5.6kW 6.0kW 7.1kW 12. 1Way Cassette 14. 2Way Cassette 16. 360 Cassette 20. 4Way Cassette 24. Mini 4Way Cassette 26. Slim Duct 30. MSP Duct 34. MSP Duct S Indoor Units 40. HSP Duct 42. Console 44. Ceiling 46. Wall (Neo Forte-E) 48. Wall (A3050-E) 50. Floor Uncased 54. Hydro Unit HE 1 Phase (Heating) 54. Hydro Unit HT 1 Phase + 3 Phase (Heating) Type Model Details Model 52. ERV Plus 500 1000 OAP (Outdoor Air Processer) AM140JNEPEH AM220JNEPEH AM280JNEPEH These products contain fluorinated greenhouse gas (R410A) HT Hydro Unit (R134a). Individual Control Centralised Control Controls Wireless Remote Controller Wired Controller Simplified Remote Controller Wireless Signal Receiver External Remote Temp. Sensor Wi-Fi Controller Centralised Controller MR-EH00 MWR-WE10N MWR-SH00N MWR-SH10N MRK-A10N MRW-TA MIM-H03N MCM-A300N 10 www.samsung.com/uk/dvms

Capacity 8.2kW 9.0kW 11.2kW 12.8kW 14.0kW 16.0kW 18.0kW 22.0kW 25.0kW 28.0kW 31.5kW 50.4kW VRF INDOOR UNITS Details Model Description Relevant Unit MXD-K025AN MXD-K050AN 7.0kW~8.75kW 14.0kW~17.5kW 2.5HP to 40HP with Discharge Air Temperature Control Building Management System Power Monitoring Interface Module Converter CONTROLS External DMS 2.5 S-NET 3 Lonworks G/W BACnet G/W Electricity Meter Power Monitoring Contact Module NASA Converter S-Net Converter MIM-D01AN MST-P3P MIM-B18BN MIM-B17BN MIM-B16N MCM-C210N MIM-B14 MIM-N01 MIM-C02N Samsung Air Conditioning 11

1Way Cassette Specifications Model Name AM017HN1DEH AM022HN1DEH AM022FN1DEH AM028FN1DEH AM036FN1DEH AM056JN1DEH AM071JN1DEH Capacity (Nominal) Cooling 1.70 2.20 2.80 3.60 5.6 7.1 Heating 1.90 2.50 3.20 4.00 6.3 8.0 VRF INTDOOR UNITS Perfomance Capacity (UK Conditions) Fan Air Flow Rate H/M/L (UL) Piping Connections Cooling (Total) *5) kw 1.4 1.8 2.3 2.9 4.6 5.8 Cooling *5) (Sensible) 1.1 1.4 1.8 2.4 3.8 4.5 Heating *6) 1.8 2.4 2.7 3.3 5.3 6.7 CMM 4.80 / 4.30 / 4.10 5.10 / 4.60 / 4.30 6.00 / 5.00 / 4.00 7.00 / 6.00 / 5.00 8.00 / 7.00 / 6.00 16 /14 /12.5 17/15.5/14 l/s 80 / 71 / 68 85 / 76 / 71 100 / 83 / 66 116 / 100 / 83 133 / 116 / 100 267/233/208 283/258/233 Liquid Pipe 1/4 Ø, inch Gas Pipe 1/2 Fuse Rating Sound Dimensions 5A Pressure High/Mid/Low 27.0 I 24.0 I 21.0 27.0 I 25.0 I 23.0 29.0 I 27.0 I 24.0 35.0 I 31.0 I 27.0 36/33/31 39/37/34 db(a) Power Cooling 46.0 48.0 51.0 53.0 58.0 58 60 Net Weight kg 8.00 10.50 10.50 14.5 14.5 Net Dimensions (WxHxD) mm 740 x 135 x 360 970 x 135 x 410 1200 x 138 x 450 1200 x 138 x 450 Panel Model - PC1MWSKAN PC1NUSMAN PC1BWSMAN PC1BWSMAN Panel Size Panel Net Weight kg 2.60 3.00 6.30 Net Dimensions (WxHxD) mm 900 x 25 x 420 1,180 x 25 x 460 1410 x 23 x 500 Additional Accessories Drain Pump -/Model Built-in Drain Pump Max. Lifting Height / Displacement mm/litre/h 750/24 Air Filter - Long life filter Panel Option - PC1NUPMAN - These products contain Fluorinated greenhouse gas R410A (GWP=2088). Slim Design Our slim 1Way Cassette indoor unit is only 135mm thick. It can easily be installed onto ceilings with a minimum amount of space. Stylish Panel Options Three stylish panel options are available (depending upon model size) to match the installation environment. Wave panel for H1NDEH models. *Specifications may be subject to change without prior notice for product improvement. *1) Mode - HP : Heat Pump, HR : Heat Recovery. 12 www.samsung.com/uk/dvms

1Way Cassette Dimensional Drawings AM017/022HN1DEH, AM022/028/036FN1DEH, AM056/71JN1DEH Units: mm Models No. AM017/022HN1DEH Name 1 Refrigerant gas pipe 2 Refrigerant liquid pipe 3 Drain pipe 4 Power supply wiring conduit 5 Communication wiring conduit 6 Air inlet grille 7 Air outlet louver VRF INDOOR UNITS Models No. AM022/028/036FN1DEH Name 1 Refrigerant gas pipe 2 Refrigerant liquid pipe 3 Condensate drain Power and communication 4 wiring conduits 5 Air discharge louver 6 Air suction grille Samsung Air Conditioning 13

2Way Cassette Specifications Model Name AM056FN2DEH AM071FN2DEH Capacity (Nominal) Cooling *2) 5.6 7.1 Heating *3) 6.3 8.0 VRF INTDOOR UNITS Perfomance Capacity (UK Conditions) Fan Air Flow Rate H/M/L (UL) Piping Connections Cooling (Total) *5) kw 4.6 5.8 Cooling *5) (Sensible) 3.4 4.4 Heating *6) 5.3 6.7 CMM 14 / 13 / 12 15 / 14 / 13 l/s 233 / 216 / 200. 250 / 233 / 216 Liquid Pipe 1/4 3/8 Ø, inch Gas Pipe 1/2 5/8 Fuse Rating 5A Sound Sound Pressure High/Mid/Low *4) dba 38 / 37 / 35 41 / 39 / 37 Dimensions Net Weight kg 21.00 22.00 Net Dimensions (WxHxD) mm 890 x 230 x 575 Panel Model - PC2NUSMEN Panel Size Panel Net Weight kg 4.00 Net Dimensions (WxHxD) mm 1030 x 25 x 650 Additional Accessories Drain Pump -/Model Built-in Drain Pump Max. Lifting Height / Displacement mm/litre/h 750 / 24 Air Filter - Long life filter These products contain Fluorinated greenhouse gas R410A (GWP=2088). Standard formula for Easy Installation The dimensions of 2Way Cassette air conditioner allow for easy installation into standard ceiling grids (600Wx600D) in such a way that everything just falls into place. 1030mm Twin Cross Flow Fan 2Way Cassette type unit is a perfect fit for long and narrow rectangular spaces. The Twin Cross Flow Fan inside 2Way Cassette will spread cool or warm air even further and wider with less noise. 650mm 600mm 600mm Cross Flow Fans *Specifications may be subject to change without prior notice for product improvement. *1) Mode - HP : Heat Pump, HR : Heat Recovery. 14 www.samsung.com/uk/dvms

2Way Cassette Dimensional Drawing Units: mm VRF INDOOR UNITS No. Name Description 5.6kW 7.1kW 1 Liquid pipe connection Ø6.35 Flare Ø9.52 Flare 2 Gas pipe connection Ø12.70 Flare Ø15.88 Flare 3 Drain pipe connection VP25 (OD 32, ID 25) 4 Conduit for power supply and communication wiring - 5 Air inlet grille - 6 Air outlet louver - 7 Fresh air intake - Samsung Air Conditioning 15

360 Cassette Specifications Model Name AM045KN4DEH AM056KN4DEH AM071KN4DEH Capacity (Nominal) Cooling *2) 4.5kW 5.6kW 7.1kW Heating *3) 5.0kW 6.3kW 8.0kW VRF INTDOOR UNITS Perfomance Capacity (UK Conditions) Fan Air Flow Rate H/M/L (UL) Piping Connections Field Wiring Fuse Rating Cooling (Total) *5) kw 3.7kW 4.6kW 5.8kW Cooling *5) (Sensible) 2.8kW 3.5kW 4.5kW Heating *6) 4.2kW 5.8kW 6.7kW CMM 14.5 / 13.5 / 12.5 16.0 / 14.5 / 13.5 18.0 / 16.0 / 14.0 l/s 242 / 225 / 208 267 / 242 / 225 300 / 267 / 233 Liquid Pipe Ø, inch 1/4" 1/4" 3/8" Gas Pipe Ø, inch 1/2" 1/2" 5/8" Power Source Wire Below 20m/ over 20m mm 2 1.5-2.5 1.5-2.5 1.5-2.5 5A Sound Sound Pressure High/Mid/Low *4) dba 33 / 31 / 29 34 / 32 / 29 36 / 33 / 30 Net Weight kg 21.00 Dimensions Panel Size Net Dimensions (WxHxD) mm 947 x 281 x 947 Min. ceiling void depth square/round panel mm 233 / 205 Panel Model Square PC4NUDMAN PC4NUDMAN PC4NUDMAN Panel Net Weight kg 3.6 Net Dimensions (WxHxD) mm 1000 x 66 x 1000 Additional Accessories Drain Pump Drain Pump -/Model Built-in Max. Lifting Height / Displacement mm/litre/h 750/24 Round PC4NUNMAN PC4NUNMAN PC4NUNMAN Panel Options Square Black PC4NBDMAN PC4NBDMAN PC4NBDMAN Round Black PC4NBNMAN PC4NBNMAN PC4NBNMAN Virus Doctor MSD-CAN1 MSD-CAN1 MSD-CAN1 These products contain Fluorinated greenhouse gas R410A (GWP=2088). All round cooling and comfort The Samsung 360 Cassette air conditioner offers a brand new way of staying comfortably cool in every corner of the room. Its innovative circular design not only means it perfectly fits in everywhere, adding a sophisticated look to many different sites, but it also blows cool air in all directions, so that the whole room is the same temperature*. And its bladeless outlet ensures that cool air is gently dispersed, without creating a cold draft**, and doesn t block the air flow, even at low angles, so it expels 25% more air* and spreads it farther. * Samsung testing compared to a general 4 way cassette type air conditioner. ** Within an 9.3m radius the temperature difference is less than 0.6 o C. *Within an 9.3m radius the temperature difference is less than 0.6 C. *Specifications may be subject to change without prior notice for product improvement. *1) Mode - HP : Heat Pump, HR : Heat Recovery. 16 www.samsung.com/uk/dvms

AM090KN4DEH AM112KN4DEH AM128KN4DEH AM140KN4DEH 9.0kW 11.2kW 12.8kW 14.0kW 10.0kW 12.5kW 13.8kW 16.0kW 7.3kW 9.1kW 10.4kW 11.4kW 5.7kW 7.1kW 8.1kW 8.5kW 8.4kW 10.5kW 11.5kW 13.4kW 22.0 / 18.5 / 16.0 25.5 / 21.0 / 17.5 29.5 / 24.0 / 19.0 31.5 / 26.5 / 21.0 367 / 308 / 267 425 / 350 / 292 492 / 400/ 317 525 / 442 / 350 3/8" VRF INDOOR UNITS 5/8" 1.5-2.5 5A 40 / 36 / 32 40 / 36 / 32 42 / 38 / 33 44 / 40 / 35 21.00 24.00 947 x 281 x 947 947 x 365 x 947 947 x 365 x 947 947 x 365 x 947 233 / 205 317 / 289 317 / 289 317 / 289 PC4NUDMAN 3.6 1000 x 66 x 1000 Built-in 750/24 PC4NUNMAN PC4NUNMAN PC4NUNMAN PC4NUNMAN PC4NBDMAN PC4NBDMAN PC4NBDMAN PC4NBDMAN PC4NBNMAN PC4NBNMAN PC4NBNMAN PC4NBNMAN MSD-CAN1 MSD-CAN1 MSD-CAN1 MSD-CAN1 Circular to perfectly fit in everywhere Its innovative circular design can match a multitude of interior designs, so it perfectly fits in everywhere. Its minimalist modern styling creates a sophisticated look and its circular shape stands out beautifully. Samsung Air Conditioning 17

360 Cassette Dimensional Drawings AM045/056/071/090KN4DEH VRF INTDOOR UNITS Units: mm/inches 18 www.samsung.com/uk/dvms

360 Cassette Dimensional Drawings AM112/128/140KN4DEH Units: mm/inches VRF INDOOR UNITS Samsung Air Conditioning 19

4Way Cassette Specifications Model Name AM045FN4DEH AM056FN4DEH AM071FN4DEH Capacity (Nominal) Cooling *2) 4.5 5.6 7.1 Heating *3) 5.0 6.3 8.0 VRF INTDOOR UNITS Perfomance Capacity (UK Conditions) Fan Air Flow Rate H/M/L (UL) Piping Connections Field Wiring Fuse Rating Cooling (Total) *5) kw 3.7 4.6 5.8 Cooling *5) (Sensible) 2.8 3.5 4.5 Heating *6) 4.2 5.3 6.7 CMM 14.50 / 13.50 / 12.50 15.00 / 14.00 / 13.00 17.00 / 15.50 / 14.50 l/s 241 / 225 / 208 250 / 233 / 216 283 / 258 / 241 Liquid Pipe Ø, inch 1/4 3/8 Gas Pipe Ø, inch 1/2 5/8 Power Source Wire Below 20m/ over 20m mm 2 1.5 / 2.5 5A Sound Sound Pressure High/Mid/Low *4) dba 34 / 33 / 31 36 / 35 / 34 Dimensions Net Weight kg 15.50 Net Dimensions (WxHxD) mm 840 x 204 x 840 Panel Model - PC4NUSKEN Panel Size Panel Net Weight kg 6.70 Net Dimensions (WxHxD) mm 950 x 30 x 950 Additional Accessories Drain Pump -/Model Built-in Drain Pump Max. Lifting Height / Displacement mm/litre/h 750 / 24 Air Filter - Long life filter Panel Options Waffle Black PC4NUSKAN PC4NBSKAN Virus Doctor MSD-CAN1 These products contain Fluorinated greenhouse gas R410A (GWP=2088). Stylish and Aesthetic Panel 4Way Cassette S supports two different pattern designs of panels. You can select between the Waffle and Classic pattern, depending on your interior s look or personal preference. Waffle Pattern Classic Pattern Individual Blade Control By using a remote controller, the opening angles of the 4 blades can be individually set at the same or different angles within a 32 o ~65 o range for more efficient cooling. *Specifications may be subject to change without prior notice for product improvement. *1) Mode - HP : Heat Pump, HR : Heat Recovery. 20 www.samsung.com/uk/dvms

AM090FN4DEH AM112FN4DEH AM128FN4DEH AM140FN4DEH 9.0 11.2 12.8 14.0 10.0 12.5 13.8 16.0 7.3 9.1 10.4 11.4 5.7 7.1 8.1 8.5 8.4 10.5 11.5 13.4 19.50 / 18.00 / 16.50 26.00 / 24.00 / 22.00 28.00 / 26.00 / 23.00 30.00 / 28.00 / 26.00 325 / 300 / 275 433 / 400 / 366 466 / 433 / 383 500 / 466 / 433 3/8 VRF INDOOR UNITS 5/8 1.5 / 2.5 5A 40 / 37 / 34 41 / 39 / 37 42 / 40 / 37 44 / 42 / 39 15.50 17.00 15.50 19.00 840 x 204 x 840 840 x 246 x 840 840 x 288 x 840 PC4NUSKEN 6.70 950 x 30 x 950 Built-in 750 / 24 Long life filter PC4NUSKAN PC4NBSKAN MSD-CAN1 No Overflowing Drain Water The check valve on the drain pump prevents drained water from flowing backward into the drain pan. This minimises the drain pan s water level so that you will never have to worry about water stagnation or overflowing drain water that could drip into your interior. Check Valve: Prevents drain water from reversing Check valve: Prevents drain water from reversing Minimises Minimizes Remaining Remaining Drain Water Surround Air Flow The 4-way outlet can cool every portion of your interior. The new and practical design of the blades minimises blind spots at the corners of the panel, and can almost cover a full 360 O around the indoor unit. H W ONE-WAY FLOW CLEAN CEILING NO OVERFLOW NO STAGNATION Covers 360 O Samsung Air Conditioning 21

4Way Cassette Dimensional Drawing VRF INTDOOR UNITS Units: mm Description No. Name 4.5/5.6kW 7.1/9.0kW 11.2kW Ø6.35 Flare 12.8/14.0kW Ø9.52 Flare 1 Liquid pipe connection 2 Gas pipe connection 3 Drain pipe connection 4 Conduit for power supply and communication wiring - 5 Air inlet grille - 6 Air outlet louver - 7 Sub-duct - Ø12.70 Flare Ø15.88 Flare VP25 (OD 32, ID 25) Description 4.5/5.6kW 22 www.samsung.com/uk/dvms 7.1/9.0kW 11.2kW 12.8/14.0kW A mm 204 246 288 B mm 253 295 337

Optional Accessories Virus Doctor: Healthy Air Provider Our Virus Doctor device eliminates airborne contaminants and creates even healthier air for your environments. This optional device can be easily installed by simply inserting the Virus Doctor kit into the indoor unit. The Virus Doctor device generates active hydrogen and oxygen ions which eliminate biological contaminants and active oxygen (OH-radical) in the air by turning them into harmless H 2 O. Virus Doctor Kit Virus doctor is standard on Console and A3050 wall units. Virus Doctor is optional on 360 cassette, Duct S, 11.2kW and 14kW Ceiling and ERV+ units. Virus and Active Hydrogen turns into harmless H 2 O Active Hydrogen(H) VRF INDOOR UNITS Elimination of airborne virus and bacteria (subtype H1N1) Complete eradiction of bacteria Relief of allergies by eradicating airborne allergens Neutralisation of OH-radical (as known as active oxygen) MDS Motion Detect Sensor (Mini 4Way) The world s first MDS for Mini 4Way Cassette(s) creates the ideal environment, saving energy by providing the optimised amount of airflow when needed. Oxygen(O 2- ) Energy Saving On/Off Function MDS detects when the user is absent, automatically stopping the air conditioning operation. It also automatically sets operation patterns to maximise energy efficiency. Eliminates Subtype H1N1 Virus Complete Bacteria Eradication Neutralize Active Oxygen Freedom from Allergens Pleasant and Comfortable Air MDS enables the indoor unit to avoid directly providing airflow to people and reduces the difference of thermal sensation in the body by detecting the temperature around floor. Power ON Power OFF Samsung Air Conditioning 23

Mini 4Way Cassette Specifications Model Name AM015HNNDEH AM022FNNDEH AM028FNNDEH AM036FNNDEH AM045FNNDEH AM056FNNDEH AM060FNNDEH Capacity (Nominal) Cooling *2) 1.50 2.20 2.80 3.60 4.50 5.60 6.00 Heating *3) 1.70 2.50 3.20 4.00 5.00 6.30 6.80 VRF INTDOOR UNITS Perfomance Capacity (UK Conditions) Fan Air Flow Rate H/M/L (UL) Piping Connections Cooling (Total) *5) kw 1.20 1.8 2.3 2.9 3.7 4.6 4.9 Cooling *5) (Sensible) 1.0 1.6 2.1 2.2 2.8 3.8 4.0 Heating *6) 1.4 2.4 2.7 3.3 4.2 5.3 5.9 CMM 8.2 / 7 / 6.3 9 / 7.7 / 6.5 10/ 8.5 / 7.5 10.5 / 9.5 / 8 11.5 / 10.2 / 9 13 / 11/ 9.5 13.5 / 12 / 10.2 l/s 137 / 117 / 105 150 / 128 / 108 166 / 141 / 125 175 / 158 / 133 191 / 170 / 150 216 / 183 / 158 225 / 200 / 170 Liquid Pipe 1/4 Ø, inch Gas Pipe 1/2 Fuse Rating 5A Sound Sound Pressure High/Mid/Low *4) dba 30 / 28 / 23 32 / 30 / 27 34 / 30 / 26 36 / 34 / 31 36 / 35 / 33 40 / 37 / 34 41 / 38 / 35 Dimensions Net Weight kg 12.00 Net Dimensions (WxHxD) mm 575 x 250 x 575 Panel Model - PC4SUSMEN Panel Size Panel Net Weight kg 2.70 Net Dimensions (WxHxD) mm 670 x 45 x 670 Additional Accessories Drain Pump -/Model Built-in Drain Pump Max. Lifting Height / Displacement mm/litre/h 750 / 24 Air Filter - Long life filter Panel Option PC4SUSMAN Motion Detector Sensor Virus Doctor These products contain Fluorinated greenhouse gas R410A (GWP=2088). Ideal Compact Size 4Way Mini Cassette air conditioner can be installed on one standard ceiling tile (600Wx600D), which can reduce installation time. 623mm MCR-SMA MSD-CAN1 623mm Compact and Light Unit The Samsung 4Way Mini Cassette indoor unit is now lighter in weight at 11kg. It is the lightest indoor unit in the industry, about 35% lighter than our competitor s products. 4Way Mini Cassette Conventional 35% 11kg 17kg Based on 3.5kW *Specifications may be subject to change without prior notice for product improvement. *1) Mode - HP : Heat Pump, HR : Heat Recovery. 24 www.samsung.com/uk/dvms

Mini 4Way Cassette Dimensional Drawing Units: mm VRF INDOOR UNITS No. Name Description 1 Liquid pipe connection Ø6.35 Flare 2 Gas pipe connection Ø12.70 Flare 3 Drain pipe connection VP25 (OD 32, ID 25) 4 Conduit for power supply and communication wiring - 5 Air inlet grille - 6 Air outlet louver - 7 Fresh air intake Ø100 Samsung Air Conditioning 25

Slim Duct Specifications Model Name AM017FNLDEH AM022FNLDEH AM028FNLDEH AM036FNLDEH AM045FNLDEH AM056FNLDEH Capacity (Nominal) Cooling *2) 1.7 2.2 2.8 3.6 4.5 5.6 Heating *3) 1.9 2.5 3.2 4.0 5.0 6.3 Perfomance Cooling (Total) *5) kw 1.4 1.8 2.3 2.9 3.7 4.6 VRF INTDOOR UNITS Fan Capacity (UK Conditions Air Flow Rate Cooling *5) (Sensible) 1.2 1.4 1.8 2.3 3.0 3.6 Heating *6) 1.8 2.4 2.7 3.3 4.2 5.3 H/M/L (UL) CMM 5.5 / 4.3 / 3.2 7 / 6.1 / 5.3 7.5 / 6.6 / 5.6 11 / 9.6 / 8.3 12 / 10.5 / 9 l/s 92 / 72 / 53 116 / 101 / 88 125 / 110 / 93 183 / 160 / 138 200 / 175 / 150 mmaq 0.00 / 1.00 / 3.00 0.00 / 2.00 / 4.00 External Static Pressure Min/Std/Max Pa 0.00 / 9.81 / 29.42 0.00 / 19.61 / 39.23 WG 0 / 0.039 /0.118 0 / 0.079 / 0.157 Piping Connections Fuse Rating Liquid Pipe 1/4 Ø, inch Gas Pipe 1/2 5A Sound Sound Pressure High/Mid/Low *4) dba 21 / 20 / 19 26 / 24 / 21 28 / 26 / 23 32 / 30 / 27 35 / 31 / 26 36 / 34 / 31 Dimensions Additional Accessories Net Weight kg 19.00 19.50 23.50 Net Dimensions (WxHxD) mm 700 x 199 x 600 900 x 199 x 600 Drain Pump -/Model MDP-E075SEE3D Optional Drain Pump Max. Lifting Height / mm/litre/h 750 / 24 Displacement Air Filter - Long life filter These products contain Fluorinated greenhouse gas R410A (GWP=2088). Compact Size Slim Duct S has achieved a more compact and slim size with its width, which is 200mm narrower than conventional products. This enables flexible installation and maintenance in various spaces. 900mm 900mm 700mm 700mm 200mm Narrower Flexible Installation The air inlet can be set up either on the bottom or rear of the unit, giving you greater flexibility in installation. TEX Duct Suction Duct Diffuser TEX Duct Suction Duct Diffuser *Specifications may be subject to change without prior notice for product improvement. *1) Mode - HP : Heat Pump, HR : Heat Recovery. 26 www.samsung.com/uk/dvms

AM071FNLDEH AM090FNLDEH AM112FNLDEH AM128FNLDEH AM140FNLDEH 7.1 9.0 11.2 12.8 14.0 8.0 10.0 12.5 13.8 16.0 5.8 7.3 9.1 10.4 11.4 5.0 6.3 7.7 8.8 9.6 6.7 8.4 10.5 11.5 13.4 16.5 / 15 / 13.5 29/ 27 / 25 31.2 / 29 / 27 34 / 32 / 30 36 / 34 / 32 275 / 250 / 225 483 / 450 / 416 520 / 483 / 450 566 / 533 / 500.00 600.00 / 566.67 / 533.33 0.00 / 2.00 / 4.00 0.00 / 3.00 / 6.00 VRF INDOOR UNITS 0.00 / 19.61 / 39.23 0.00 / 29.42 / 58.84 0 / 0.079 / 0.157 0 /0.118 / 0.236 3/8 5/8 5A 38 / 36 / 33 37 / 36 / 34 39 / 38 / 36 30.00 44.00 46.00 1100 x 199 x 600 1300 x 295 x 690 MDP-E075SEE3D 750 / 24 Long life filter Indoor Discharge Temperature Control Without changing the outdoor unit s setting, each ducted indoor unit or AHU kit has a discharge air temperature control function, offering greater comfort in cooling or heating mode. Target Temperature Cooling: 11~18 degrees Heating: 30~43 degrees This is set by each MWR-WE10N remote control in detailed setting mode and is only applicable to ALL ducted/ahu connected systems. Samsung Air Conditioning 27

Slim Duct Dimensional Drawings AM017/022/028/036/045/056FNLDEH Units: mm Models AM017/022/028/036FNLDEH Description No. Name 2.2kW 2.8kW 3.6kW 1 Liquid pipe connection Ø6.35 Flare VRF INTDOOR UNITS 2 Gas pipe connection Ø12.70 Flare 3 4 Drain pipe connection without optional drain pump kits Drain pipe connection with optional drain pump kits VP25 (OD 32, ID 25) VP25 (OD 32, ID 25) 5 Power supply/ Communication connection - 6 Power supply connection - 7 Air discharge grille flange - 8 Hook 3/8'' or M10 Models AM045/056FNLDEH Description No. Name 4.5kW 5.6kW 1 Liquid pipe connection Ø6.35 Flare 2 Gas pipe connection Ø12.70 Flare 3 Drain pipe connection without optional drain pump kits VP25 (OD 32, ID 25) 4 Drain pipe connection with optional drain pump kits VP25 (OD 32, ID 25) 5 Control unit - 6 Conduit for power supply and communication wiring - 7 Return air side - 8 Air outlet duct flange - 28 www.samsung.com/uk/dvms

Slim Duct Dimensional Drawings AM071/090/112/128/140FNLDEH Units: mm Model AM071FNLDEH Description No. Name 7.1kW 1 Liquid pipe connection Ø9.52 Flare 2 Gas pipe connection Ø15.88 Flare 3 Drain pipe connection without optional drain pump kits VP25 (OD 32, ID 25) 4 Drain pipe connection with optional drain pump kits VP25 (OD 32, ID 25) 5 Control unit - 6 Conduit for power supply and communication wiring - 7 Return air side - 8 Air outlet duct flange - VRF INDOOR UNITS Models AM090/112/128/140FNLDEH Description No. Name 9.0kW 11.2kW 12.8kW 14.0kW 1 Liquid pipe connection Ø9.52 Flare 2 Gas pipe connection Ø15.88 Flare 3 4 Drain pipe connection without optional drain pump kits Drain pipe connection with optional drain pump kits VP25 (OD 32, ID 25) VP25 (OD 32, ID 25) 5 Control unit - 6 Conduit for power supply and communication wiring - 7 Return air side - 8 Air outlet duct flange - Samsung Air Conditioning 29

MSP Duct Specifications Model Name AM022FNMDEH AM028FNMDEH AM036FNMDEH AM045FNMDEH Capacity (Nominal) Cooling *2) 2.2 2.8 3.6 4.5 Heating *3) 2.5 3.2 4.0 5.0 Perfomance Cooling (Total) *5) kw 1.8 2.3 2.9 3.7 VRF INTDOOR UNITS Fan Capacity (UK Conditions) Air Flow Rate Cooling *5) (Sensible) 1.5 1.9 2.5 3.2 Heating *6) 2.4 2.7 3.3 4.2 H/M/L (UL) CMM 8.50 / 7.50 / 6.30 10.00 / 9.20 / 7.50 12.00 / 10.20 / 8.80 14.00 / 12.00 / 10.50 l/s 141 / 125 / 105 166 / 153 / 125 200 / 170 / 146 233 / 200 / 175 mmaq 0.00 / 2.00 / 6.00 0.00 /4.00 / 8.00 External Static Pressure Min/Std/Max Pa 0.00 / 19.61/ 58.84 0.00 / 39.23/ 78.45 WG 0 / 0.079 / 0.236 0 / 0.157 / 0.314 Piping Connections Fuse Rating Sound Dimensions Additional Accessories Liquid Pipe 1/4 Ø, inch Gas Pipe 1/2 Sound Pressure High/Mid/ *4) Low dba 23 / 21 / 19 24 / 22 / 19 29 / 27 / 24 32 / 30 / 28 Net Weight kg 23.50 29.00 Net Dimensions (WxHxD) mm 900 x 199 x 600 900 x 260 x 480 Drain Pump -/Model MDP-E075SEE3D MDP-M075SGU3D Optional Drain Pump Max. Lifting Height / mm/litre/h 750 / 24 Displacement Air Filter - Long life filter 5A Strong and Large Coverage Area HSP duct features greater static pressure than most slim ducts: this enables you to design more inlets and outlets with longer duct work to provide even more cool or warm air to larger areas. Narrow Width MSP Duct has very narrow width of 900mm, which enables flexible installation and maintenance with its compact size, thus maximising your convenience. Silent Operation with the Static Pressure Control The external static pressure control makes it easy to design the duct work to ensure efficiency and silent operation. HSP Duct Slim Duct 0~25mmAq 0~25mmAq 0~6mmAq 0~6mmAq 900mm 900mm *Specifications may be subject to change without prior notice for product improvement. *1) Mode - HP : Heat Pump, HR : Heat Recovery. 30 www.samsung.com/uk/dvms

AM056FNMDEH AM071FNMDEH AM090FNMDEH AM112FNMDEH 5.6 7.1 9.0 11.2 6.3 8.0 10.0 12.5 4.6 5.8 7.3 9.1 3.9 5.0 6.3 7.5 5.3 6.7 8.4 10.5 14.50 / 13.00 / 11.50 18.50 / 17.00 / 15.50 19.50 / 18.00 / 16.50 27.00 / 25.00 / 23.00 241 / 216 / 191 308 / 283 / 258 325 / 300 / 275 450 / 416 / 383 0.00 /4.00 / 8.00 0.00 / 4.00 / 8.00 4.00 / 6.00 / 8.00 4.00 / 8.00 / 12.00 VRF INDOOR UNITS 0.00 / 39.23/ 78.45 0.00 / 39.23 /7 8.45 39.23 / 58.84 / 78.45 39.23 / 78.45 / 117.68 0 / 0.157 / 0.314 0 / 0.157 / 0.314 0.157 / 0.236 / 0.315 0.236 / 0.314/ 0.472 1/4 3/8 1/2 5/8 5A 5A 35 / 33 / 31 39 / 35 / 31 40 / 37 / 34 41 / 40 / 38 29.00 29.00 34.00 36.00 900 x 260 x 480 900 x 260 x 480 1150 x 260 x 480 1150 x 320 x 480 MDP-M075SGU3D MDP-M075SGU3D MDP-M075SGU1D 750 / 24 Indoor Discharge Temperature Control Without changing the outdoor unit s setting, each ducted indoor unit or AHU kit has a discharge air temperature control function, offering greater comfort in cooling or heating mode. This is set by each MWR-WE10N remote control in detailed setting mode and is only applicable to ALL ducted/ahu connected systems. Target Temperature Cooling: 11~18 degrees Heating: 30~43 degrees Samsung Air Conditioning 31

MSP Duct Dimensional Drawings AM022/028/036/045/056/071FNMDEH Units: mm Models AM022/028/036FNMDEH Description No. Name 2.2kW 2.8kW 3.6kW 1 Liquid pipe connection Ø6.35 Flare VRF INTDOOR UNITS 2 Gas pipe connection Ø12.70 Flare 3 Drain pipe connection without optional drain pump kits VP25 (OD 32, ID 25) 4 Drain pipe connection with optional drain pump kits VP25 (OD 32, ID 25) 5 Control unit - 6 Conduit for power supply and communication wiring - 7 Return air side - 8 Air outlet duct flange - Models AM045/056/071FNMDEH Description No. Name 4.5kW 5.6kW 7.1kW 1 Liquid pipe connection Ø6.35 Flare Ø6.35 Flare 2 Gas pipe connection Ø12.70 Flare Ø15.88 Flare 3 Drain pipe connection without optional drain pump kits VP25 (OD 32, ID 25) 4 Drain pipe connection with optional drain pump kits VP25 (OD 32, ID 25) 5 Control unit - 6 Conduit for power supply and communication wiring - 7 Return air side - 8 Air outlet duct flange - 32 www.samsung.com/uk/dvms

AM090/112FNMDEH Units: mm Model AM090FNMDEH Description No. Name 9.0kW 1 Liquid pipe connection Ø9.52 Flare 2 Gas pipe connection Ø15.88 Flare 3 Drain pipe connection without optional drain pump kits VP25 (OD 32, ID 25) 4 Drain pipe connection with optional drain pump kits VP25 (OD 32, ID 25) 5 Control unit - 6 Conduit for power supply and communication wiring - 7 Return air side - 8 Air outlet duct flange - VRF INDOOR UNITS Model AM112FNMDEH Description No. Name 11.2kW 1 Liquid pipe connection Ø9.52 Flare 2 Gas pipe connection Ø15.88 Flare 3 Drain pipe connection without optional drain pump kits VP25 (OD 32, ID 25) 4 Drain pipe connection with optional drain pump kits VP25 (OD 32, ID 25) 5 Control unit - 6 Conduit for power supply and communication wiring - 7 Return air side - 8 Air outlet duct flange - Samsung Air Conditioning 33

MSP Duct S Specifications Model Name AM036HNMPKH AM045HNMPKH AM056HNMPKH AM071HNMPKH Capacity (Nominal) Cooling *2) 3.6 4.5 5.6 7.1 Heating *3) 4.0 5.0 6.3 8.0 Perfomance Cooling (Total) *5) kw 2.9 3.7 4.6 5.8 VRF INTDOOR UNITS Fan Capacity (UK Conditions) Air Flow Rate External Static Pressure Cooling *5) (Sensible) 2.3 3.1 3.9 5.0 Heating *6) 3.3 4.2 5.3 6.7 H/M/L (UL) Min/Std/Max CMM 12.00 / 9.50 / 8.00 14.00 / 11.00 / 8.00 12.00 / 9.50 / 8.00 22.00 / 19.00 / 16.00 l/s 200 / 158 / 133 233 / 183 / 133 267 / 225 / 183 367 / 317 / 267 mmaq 2.50 / 15.00 3.00 / 15.00 3.00 / 15.00 Pa 24.50 / 147.00 29.4 / 147.00 29.40 / 147.00 Piping Connections Liquid Pipe 1/4 3/8 Ø, inch Gas Pipe 1/2 5/8 Fuse Rating 5A 5A Sound Dimensions Sound Pressure High/Mid/Low *4) dba 29 / 26 / 23 31 / 28 / 24 32 / 29 / 25 37 / 33 / 29 Sound Power (cooling) 47.0 49.0 57.0 Net Weight kg 25.5 25.50 Net Dimensions (WxHxD) mm 850 x 250 x 700 850 x 250 x 700 Additional Accessories Optional Drain Pump Virus Doctor Drain Pump -/Model MDP-G075SP Max. Lifting Height / Displacement mm/litre/h MSD-EAN1 Air Filter - These products contain Fluorinated greenhouse gas R410A (GWP=2088). FME/FMC (HNMP models) (Flat Micro-channel Evaporator/Condenser) Samsung s FME/FMC technology achieves a 30% increase in efficiency compared with the conventional fin and tube type. It has also enabled a 30% decrease in unit size. Heat Exchange Ratio Fin and Tube 100% FMC 130% Enhanced Performance 30% Enhanced heat exchange ratio Anti-Corrosion Coating Corrosion resistance has been improved compared to current model Slim Fit Compact Slim Fit design has reduced volume and weight compared to conventional air conditioners. It s 30% smaller, so it fits into small spaces. Although the size is smaller, efficiency is increased. 30% Less volume vs conventional Wide Range of ESP right capacity, right ESP, and right-sized product for our customers. *Specifications may be subject to change without prior notice for product improvement. *1) Mode - HP : Heat Pump, HR : Heat Recovery. 34 www.samsung.com/uk/dvms

AM090HNMPKH AM112HNMPKH AM128HNMPKH AM140HNMPKH 9.0 11.2 12.8 14.0 10.0 12.5 13.8 16.0 7.3 9.1 10.4 11.4 6.5 7.8 8.9 9.6 8.4 10.5 11.5 13.4 29.00 / 25.00 / 22.00 35.00 / 29.00 / 22.00 38.00 / 32.00 / 25.00 42.00 / 42.00 / 25.00 483 / 417 / 367 583 / 483 / 367 633 / 533 / 417 700 / 567 / 417 4.00 / 15.00 5.20 / 15.00 VRF INDOOR UNITS 39.20 / 147.00 50.96 / 147.00 3/8 5/8 5A 38 / 35 / 32 39 / 36 / 32 40 / 37 / 32 58.0 62.0 63.0 65.0 32.50 38.50 1200 / 250 / 700 1300 x 300 x 700 MDP-G075SP 750 / 24 MSD-EAN1 Long life filter Indoor Discharge Temperature Control Without changing the outdoor unit s setting, each ducted indoor unit or AHU in cooling or heating mode. Virus Doctor Kit This is set by each MWR-WE10N remote control in detailed setting mode and is only applicable to ALL ducted/ahu connected systems. Target Temperature Cooling: 11~18 degrees Heating: 30~43 degrees Virus and Active Hydrogen turns into harmless H 2 O Active Hydrogen(H) Virus Doctor (optional accessory) Our Virus Doctor device eliminates airborne contaminants and creates even healthier air for your environments. This optional device can be easily installed by simply inserting the Virus Doctor kit into the indoor unit. Oxygen(O 2- ) The Virus Doctor device generates active hydrogen and oxygen ions which eliminate biological contaminants and active oxygen (OH-radical) in the air by turning them into harmless H 2 O. Elimination of airborne virus and bacteria (subtype H1N1) Complete eradiction of bacteria Relief of allergies by eradicating airborne allergens Neutralisation of OH-radical (as known as active oxygen) Eliminates Subtype H1N1 Virus Complete Bacteria Eradication Neutralize Active Oxygen Freedom from Allergens Samsung Air Conditioning 35

MSP Duct S Dimensional Drawings AM036/045/056/071HNMPKH Units: mm VRF INTDOOR UNITS Models AM036/045/056/071HNMPKH No. Name 1 Refrigerant liquid pipe 2 Refrigerant gas pipe 3 Condensate drain 4 Power and communication wiring conduits 5 Refrigerant pipe conduits 6 Supply air flange 7 Return air flange 8 Hook 36 www.samsung.com/uk/dvms

AM090HNMPKH Units: mm VRF INDOOR UNITS Models AM090HNMPKH No. Name 1 Refrigerant liquid pipe 2 Refrigerant gas pipe 3 Condensate drain 4 Power and communication wiring conduits 5 Refrigerant pipe conduits 6 Supply air flanges 7 Return air flange 8 Hook Samsung Air Conditioning 37

MSP Duct S Dimensional Drawings AM128/140HNMPKH Units: mm VRF INTDOOR UNITS Models AM045/056/071HNMPKH No. Name 1 Refrigerant liquid pipe 2 Refrigerant gas pipe 3 Condensate drain 4 Power and communication wiring conduits 5 Refrigerant pipe conduits 6 Supply air flanges 7 Return air flange 8 Hook 38 www.samsung.com/uk/dvms

Air Handling Unit (AHU) Kit The Samsung AHU kit allows DVM S outdoor units to connect to third-party AHUs. Line-up 4-Kit line-up: 2.5HP~10HP. Multiple kits can be used together up to 80HP on a single DVM S system Use on all VRF (HP/HR) Can be installed on systems with other indoor unit types Self control (sensor included) Simple BMS can be applied 0~10V control Compressor capacity and super heat control Discharge temperature control AHU Kit Contents Control Kit (PCB, Terminal Block (contact module) in IP54 enclosure EEV (filter included) Temperature Sensor Optional Accessories Wired Remote Controller Central Controller AHU icon option DMS2 use AHU parameters in control Logic Programming VRF INDOOR UNITS AHU Specifications AHU Capacity Allowance (kw) AHU Internal Heat Exchanger Volume Allowance (cm 3 ) AHU Kit Model Capacity Minimum Maximum Minimum Maximum MXD-K025AN 2.5HP 7 8.75 1,200 1,500 MXD-K050AN 5.0HP 14 17.5 2,150 2,688 MXD-K075AN 7.5HP 21 26.25 3,100 3,875 MXD-K100AN 10HP 28 35 4,000 5,000 Example Outdoor unit Communication F1, F2 EEV Kit EEV Control Liquid Pipe Return Air Exhaust Air Eva in Sensor Fresh Air Sensor Supply Air AHU Fan Control Room Sensor Fan Feedback AHU Controller Gas pipe Eva out Sensor Samsung Air Conditioning 39

HSP Duct Specifications Model Name AM112HNHPKH AM128HNHPKH AM140HNHPKH AM180JNHFKH AM224JNHFKH AM280FNHDEH Capacity (Nominal) Cooling *2) 11.2 12.8 14.0 18.0 22.4 28.0 Heating *3) 12.5 13.8 16.8 20.0 25.0 31.5 Perfomance Cooling (Total) *5) kw 9.1 10.4 11.4 15.02 18.75 23.3 VRF INTDOOR UNITS Fan Capacity (UK Conditions) Air Flow Rate External Static Pressure Cooling *5) (Sensible) 7.8 8.9 9.6 11.42 13.68 19.9 Heating *6) 10.5 11.5 13.4 19.32 24.14 30.4 H/M/L (UL) Min/Std/Max CMM 35 / 29 / 22 38 / 32 / 25 42 / 34 / 25 58 / 50 / 43 72 / 61 / 50 72 / 65 / 58 l/s 583 / 483 / 367 633 / 533 / 417 700 / 567 / 417 967 / 833 / 717 1,200 / 1,017 / 833 1,200 / 1,083 / 966 mmaq 3 / 6 / 20 5 / 7.34 / 20 5 / 15 / 28 Pa 29 / 61 / 196 49 / 72 / 196 49.03 / 147.10 / 274.59 Piping Connections Liquid Pipe 3/8 Ø, inch Gas Pipe 5/8 3/4 7/8 Fuse Rating 5A 13A Sound Sound Pressure High/Mid/Low *4) dba 38 / 35 / 32 39 / 36 / 32 40 / 37 / 32 43 / 39 / 35 44 / 40 / 36 48 / 46 / 43 Dimensions Net Weight kg 46.5 82.5 89 Net Dimensions (WxHxD) mm 1,300 x 300 x 700 1,350 x 450 x 910 89 Additional Accessories Optional Drain Pump Drain Pump -/Model MDP-G075SP MDP-N047SNC1D Max Lifting Height / Displacement mm/litre/h 750/24 Air Filter - - These products contain Fluorinated greenhouse gas R410A (GWP=2088). High External Static Pressure To properly deal with unexpected various installation conditions, HSP Duct is designed to manage high external static pressures up to 28mmAq. Strong and Large Coverage Area HSP duct features greater static pressure than most slim ducts: this enables you to design more inlets and outlets with longer duct work to provide even more cool or warm air to larger areas. 11.2 14kW 22.4 28kW 28mmAq HSP Duct 20mmAq HSP Duct Company A HSP Duct 0~28mmAq 0~25mmAq *Specifications may be subject to change without prior notice for product improvement. *1) Mode - HP : Heat Pump, HR : Heat Recovery. 40 www.samsung.com/uk/dvms

HSP Duct Dimensional Drawings AM112/128/140/220HNHPKH Units: mm VRF INDOOR UNITS Models AM112/128/140/220HNHPKH No. Name 1 Refrigerant liquid pipe 2 Refrigerant gas pipe 3 Condensate drain 4 Power and communication wiring conduits 5 Refrigerant pipe conduits 6 Supply air flange 7 Return air flange 8 Hook Samsung Air Conditioning 41

Console Specifications Model Name AM022KNJDEH AM028FNJDEH AM036FNJDEH AM045KNJDEH AM056FNJDEH Capacity (Nominal) Cooling *2) 2.2 2.8 3.6 4.5 5.6 Heating *3) 2.5 3.2 4.0 3.7 6.3 VRF INTDOOR UNITS Perfomance Capacity (UK Conditions) Fan Air Flow Rate H/M/L (UL) Piping Connections Cooling (Total) *5) kw 1.8 2.3 2.9 2.7 4.5 Cooling *5) (Sensible) 1.5 2.0 2.3 4.4 3.5 Heating *6) 2.4 2.7 3.3-5.2 CMM 6.3/5.4/4.9 7.00 / 6.00/ 5.00 8.50 / 7.50 / 6.50 11.3/9.8/8.2 13.00 / 11.50 / 10.00 l/s 105/90/82 116 / 100 / 83 141 / 125 / 108 188/163/137 216 / 191 / 166 Liquid Pipe 1/4 Ø, inch Gas Pipe 1/2 Drain Pipe Ø, mm ID 18 HOSE Fuse Rating 5A Sound Sound Pressure High/Mid/Low *4) dba 34/32/30 38 / 36 / 34 39 / 37 / 34 42/39/36 43 / 40 / 37 Dimensions Additional Accessories Net Weight kg 15.5 16.00 Net Dimensions (WxHxD) mm 720 x 620 x 199 Air Filter - Long life filter Virus Doctor Built-in These products contain Fluorinated greenhouse gas R410A (GWP=2088). Slim Design You won t find anything slimmer than this: the new Console type air conditioner is only 199mm thick, the slimmest on the market, and its unobtrusive design easily integrates into your decor. 2Way Air Outlets There are two separate air outlets for cooling and heating. The warmer air comes out from the bottom part of the air outlet to spread the warm air evenly throughout the room. Stay cooler and warmer in every corner of your room. 199mm *Specifications may be subject to change without prior notice for product improvement. *1) Mode - HP : Heat Pump, HR : Heat Recovery. 42 www.samsung.com/uk/dvms

Console Dimensional Drawings AM028/036/056FNJDEH, AM022/045KNJDEH Units: mm VRF INDOOR UNITS Models AM028/036FNJDEH/AM022KNJDEH Description No. Name 2.2kW 3.6kW 1 Liquid pipe connection Ø6.35 Flare 2 Gas pipe connection Ø12.70 Flare 3 Drain pipe connection ID18 Hose 4 Conduit for power supply and communication wiring - 5 Air inlet grille - 6 Air outlet louver - Model AM056FNJDEH/AM045KNJDEH Description No. Name 5.6kW 1 Liquid pipe connection Ø6.35 Flare 2 Gas pipe connection Ø12.70 Flare 3 Drain pipe connection ID18 Hose 4 Conduit for power supply and communication wiring - 5 Air inlet grille - 6 Air outlet louver - Samsung Air Conditioning 43

Ceiling Specifications Model Name AM056FNCDEH AM071FNCDEH AM112JNCDKH AM140JNCDKH Capacity (Nominal) Cooling *2) 5.6 7.1 11.2 14.0 Heating *3) 6.3 8.0 12.5 16.0 VRF INTDOOR UNITS Perfomance Capacity (UK Conditions) Fan Air Flow Rate H/M/L (UL) Piping Connections Cooling (Total) *5) kw 4.6 5.8 9.1 11.4 Cooling *5) (Sensible) 3.5 4.4 7.1 8.5 Heating *6) 5.3 6.7 10.5 13.4 CMM 14.00 / 13.00/ 12.00 18.00 / 16.50 / 15.00 29.3/23.9/18.5 36.4/30.8/26.0 l/s 233 / 216 / 200 300 / 275 / 250 488/398/308 607/513/433 Liquid Pipe 1/4 3/8 Ø, inch Gas Pipe 1/2 5/8 Refrigerant Control EEV Kit required EEV Included Fuse Rating 5A Sound Sound Pressure High/Mid/Low *4) dba 40 / 37 / 34 44 / 42 / 40 45/41/37 46/43/38 Dimensions Additional Accessories Net Weight kg 21.00 33.5 42.5 Net Dimensions (WxHxD) mm 1000 x 650 x 200 1350 x 235 x 675 1650 x 235 x 675 Air Filter - Long life filter These products contain Fluorinated greenhouse gas R410A (GWP=2088). 2Way Installation (5.6 and 7.1kW models) Depending on the available space and the purpose of the air conditioner, the indoor unit can be installed under the ceiling or on the floor. Under Ceiling Floor Standing Virus Doctor (11.2 and 14kW models) Our Virus Doctor eliminates airborne contaminants and creates even healthier air for your environments. This optional device can be easily installed by simply installing the Virus Doctor kit into the indoor unit. The Virus Doctor device generates active hydrogen and oxygen ions which eliminate biological contaminants and active oxygen (OH-radical) in the air by turning them into harmless H 2 O. Elimination of airborne virus and bacteria (subtype H1N1) Complete eradication of bacteria Relief of allergies by eradicating airborne allergens Neutralising of OH-radical (as known as active oxygen) Oxygen(O 2- ) Active Hydrogen(H) Virus and Active Hydrogen turns into harmless H 2 O Eliminates Subtype H1N1 Virus Complete Bacteria Eradication Neutralize Active Oxygen Freedom from Allergens *Specifications may be subject to change without prior notice for product improvement. *1) Mode - HP : Heat Pump, HR : Heat Recovery. 44 www.samsung.com/uk/dvms

Ceiling Dimensional Drawings AM056/071FNCDEH AM112/140JNCDKH Units: mm Models AM056/071FNCDEH Description No. Name 5.6kW 7.1kW 1 Liquid pipe connection Ø6.35 Flare Ø9.52 Flare 2 Gas pipe connection Ø12.70 Flare Ø15.88 Flare 3 Drain pipe connection ID18 Hose 4 Conduit for power supply and communication wiring - 5 Air inlet grille - 6 Air outlet louver - VRF INDOOR UNITS Models No. AM112/140JNCDKH Name 1 Refrigerant gas pipe 2 Refrigerant liquid pipe 3 Condensate drain 4 Conduits for power supply and communication wiring 5 Air inlet grille 6 Air outlet louver Samsung Air Conditioning 45

Wall (Neo-Forte E) Specifications Model Name AM015HNQDEH AM022FNQDEH AM028FNQDEH AM036FNQDEH AM045FNQDEH AM056FNQDEH AM071FNQDEH Capacity (Nominal) Cooling *2) 1.5 2.2 2.8 3.6 4.5 5.6 6.8 Heating *3) 1.7 2.5 3.2 4.0 5.0 6.3 7.0 VRF INTDOOR UNITS Perfomance Capacity (UK Conditions) Fan Air Flow Rate H/M/L (UL) Piping Connections Cooling (Total) *5) kw 1.2 1.8 2.3 2.9 3.7 4.6 5.5 Cooling *5) (Sensible) 1.0 1.5 1.8 2.2 2.7 3.4 4.1 Heating *6) 1.4 2.4 2.7 3.3 4.4 5.3 5.9 CMM 5.4 / 5.1 / 4.8 7.8 / 6.8 / 5.8 9.3 / 8.3 / 7.3 11.7 / 10.2 / 8.7 13 / 10.5 / 9 14 / 12.5 / 11 l/s 90/ 85 / 80 130 / 113 / 96 155 / 138 / 121 195 / 170 / 145 216 / 175 / 150 233 / 208 / 183 Liquid Pipe Ø, inch 1/4 3/8 Gas Pipe Ø, inch 1/2 5/8 Fuse Rating 5A Sound Sound Pressure High/Mid/Low *4) dba 26 / 25 / 24 30 / 28 / 26 37 / 33 / 29 39 / 37 / 35 41 / 38 / 35 44 / 40 / 35 Dimensions Additional Accessories Net Weight kg 8.3 13.5 Net Dimensions (WxHxD) mm 825 x 285 x 189 1,065 x 298 x 218 Drain Pump Drain Pump -/Model - Max. Lifting Height / Displacement mm/litre/ h Air Filter - Long life filter - These products contain Fluorinated greenhouse gas R410A (GWP=2088). *Specifications may be subject to change without prior notice for product improvement. *1) Mode - HP : Heat Pump, HR : Heat Recovery. 46 www.samsung.com/uk/dvms

Wall (Neo-Forte E) Dimensional Drawings AM015HNQ AMS022/028/036/045/056/071FNQ Units: mm VRF INDOOR UNITS Models AM022/028/036FNQ Description No. Name 2.2kW 2.8kW 3.6kW 1 Liquid pipe connection Ø6.35 Flare 2 Gas pipe connection Ø12.70 Flare 3 Drain pipe connection ID18 Hose 4 Conduit for power supply and communication wiring - 5 Air inlet grille - 6 Air outlet louver - Models AM045/056/071FNQ Description No. Name 4.5kW 5.6kW 7.1kW 1 Liquid pipe connection Ø6.35 Flare Ø9.52Flare 2 Gas pipe connection Ø12.70 Flare Ø15.88 Flare 3 Drain pipe connection ID18 Hose 4 Conduit for power supply and communication wiring - 5 Air inlet grille - 6 Air outlet louver - Samsung Air Conditioning 47

Wall (A3050-E) Specifications Model Name AM015JNVDKH AM022JNVDKH AM028JNVDKH AM036JNVDKH AM045JNVDKH AM056JNVDKH AM071JNVDKH AM082JNVDKH Capacity (Nominal) Cooling *2) 1.5 2.2 2.8 3.6 4.5 5.6 7.1 8.2 Heating *3) 1.7 2.5 3.2 4.0 5.0 6.3 8.0 8.5 VRF INTDOOR UNITS Perfomance Capacity (UK Conditions) Fan Air Flow Rate H/M/L (UL) Piping Connections Cooling (Total) *5) kw 1.2 1.8 2.3 2.9 3.7 4.6 5.8 6.7 Cooling *5) (Sensible) 1.0 1.5 1.8 2.2 2.7 3.4 4.3 5.0 Heating *6) 1.6 2.4 2.7 3.3 4.2 5.3 6.7 7.2 CMM 4.4/4.2/3.8 5.4/4.7/4.0 5.7/5/4.3 7.1/5.7/4.6 8.9/7.5/6.0 11.8/10.0/8.2 14.8/12.4/10.0 16.7/14.3/12.4 l/s 73/70/63 90/78/67 95/83/72 118/95/77 148/125/100 197/167/137 247/207/167 279/238/207 Liquid Pipe Ø, inch 1/4 3/8 Gas Pipe Ø, inch 1/2 5/8 Fuse Rating Sound Dimensions Additional Accessories Sound Pressure High/Mid/ *4) Low dba 28/25/24 33/29/25 36/31/25 37/34/30 41/38/34 39/36/33 44/41/36 47/43/40 Net Weight kg 7.9 8.0 9.6 14.5 Net Dimensions (WxHxD) mm 750 x 249 x 246 826 x 261 x 261 1065 x 301 x 294 Drain Pump -/Model - Drain Pump Max. Lifting Height / Displacement mm/litre/h - Air Filter - Long life filter 5A Virus Doctor - Built in These products contain Fluorinated greenhouse gas R410A (GWP=2088). Virus Doctor Our Virus Doctor eliminates airborne contaminants and creates even healthier air for your environments. This optional device can be easily installed by simply installing the Virus Doctor kit into the indoor unit. Active Hydrogen(H) The Virus Doctor device generates active hydrogen and oxygen ions which eliminate biological contaminants and active oxygen (OH-radical) in the air by turning them into harmless H 2 O. Elimination of airborne virus and bacteria (subtype H1N1) Complete eradication of bacteria Relief of allergies by eradicating airborne allergens Neutralising of OH-radical (as known as active oxygen) Oxygen(O 2- ) Virus and Active Hydrogen turns into harmless H 2 O Cools faster, further and wider The Samsung Air Conditioner has been designed from the ground up to be outstandingy efficient. Its uniquely triangular design has a wider intake, so more air can be drawn in. The improved width and angle of its outlet, extra v-blades and a bigger fan also ensure that air is cooled and expelled faster and further. So refreshingly cool air reaches every corner of your room without blind spots. Eliminates Subtype H1N1 Virus Complete Bacteria Eradication Neutralize Active Oxygen Freedom from Allergens 48 www.samsung.com/uk/dvms

Wall (A3050-E) Dimensional Drawings AM015/022/028/036/045/056/071/082JNVDKH Units: mm Models AM015/022/028JNVDKH VRF INDOOR UNITS Description No. Name 1.5kW 2.2kW 1 Refrigerant gas pipe Ø12.7 Flare 2 Refrigerant liquid pipe Ø6.35 Flare 3 Drain pipe connection ID18 Hose Models 2.8kW AM036/045/028JNVDKH Models AM056/071/082JNVDKH Description No. Name Description No. 3.6kW Name 4.5kW 5.6kW 1 Refrigerant gas pipe Ø12.7 Flare 1 Refrigerant gas pipe Ø12.7 Flare 2 Refrigerant liquid pipe Ø6.35 Flare 2 Refrigerant liquid pipe Ø6.35 Flare 3 Drain pipe connection ID18 Hose 3 Drain pipe connection 7.1kW 8.2kW Ø15.88 Flare Ø9.52 Flare ID 18 Hose Samsung Air Conditioning 49

Floor (uncased) Specifications Model Name AM036FNFDEH AM056FNFDEH AM071FNFDEH Capacity (Nominal) Cooling *2) 3.6 5.6 7.1 Heating *3) 4.0 6.3 8.0 VRF INTDOOR UNITS Perfomance Capacity (UK Conditions) Fan Air Flow Rate H/M/L (UL) Fan Cooling (Total) *5) kw 3.3 4.9 5.9 Cooling *5) (Sensible) 2.7 3.9 4.5 Heating *6) 3.9 5.9 7.1 CMM 10.00 / 8.50 / 6.00 15.50 / 14.00 / 11.00 l/s 166 / 141 / 100 258 / 233 / 183 Liquid Pipe 1/4 3/8 Ø, inch Gas pipe 1/2 5/8 Static Pressure Pa 20 20 Fuse Rating Sound Dimensions Additional Accessories Sound Pressure High/Mid/ *4) Low dba 37 / 32 / 27 40 / 36 / 32 Net Weight kg 23.0 28.5 Net Dimensions (WxHxD) mm 945 x 600 x 220 1225 x 600 x 220 Air Filter - Long life filter 5A These products contain Fluorinated greenhouse gas R410A (GWP=2088). needs of spaces with a high ceiling and many windows whilst maintaining the desired temperature. *Specifications may be subject to change without prior notice for product improvement. *1) Mode - HP : Heat Pump, HR : Heat Recovery. 50 www.samsung.com/uk/dvms

Floor (uncased) Dimensional Drawing Units: mm VRF INDOOR UNITS Model A B C AM036FNFDEH 945 730 700 AM056/071FNFDEH 1,225 1,010 980 Description No. Name 3.6kW 5.6kW 7.1kW 1 Liquid pipe connection Ø6.35 Flare Ø6.35 Flare Ø9.52 Flare 2 Gas pipe connection Ø12.70 Flare Ø12.70 Flare Ø15.88 Flare 3 Drain pipe connection ID18 Hose 4 Power wiring - 5 Air inlet grille - 6 Air outlet louver - Samsung Air Conditioning 51

ERV Plus Specifications Note: Standalone ERV Air to Air Heat exchangers can be found on page 91. *Refer to the following capacities when using the product with outdoor unit: AM050FNKDEH: 3.6kW, AM100FNKDEH: 7.1 kw Model Name AM050FNKDEH AM100FNKDEH Power Supply Ø, #, V, Hz 1, 2, 220~240, 50 Turbo - 70 Cooling High - 70 VRF INTDOOR UNITS Performance Temperature Exchange Efficiency Enthalpy Exchange Efficiency Heating Cooling Heating Low - 74 Turbo - 75 High - 75 Low - 79 Turbo - 60 62 High - 60 62 Low - 66 68 Turbo - 73 75 High - 73 75 Low - 79 81 Fan Outside Air Processing Capacity Air Flow Rate External Static Pressure Turbo/High/Low (UL) Turbo/High/Low Cooling *1) (DX Coil/ Element) Heating *2) (DX Coil/ Element) - 5.1(3.6/1.5) 11.5(7.1/3.4) - 6.5(4.0/2.5) 13.2(8.0/5.2) CMH 500 / 500 / 360 1000 / 1000 / 690 l/s 139 / 139/ 100 278 / 278 / 192 mmaq 16.3 / 10.2 / 8.7 15.3 / 9.2 / 7.6 Pa 160 / 100 / 85 150 / 90/ 75 Piping Connections Fuse Rating Sound Pressure Dimensions Additional Accessories Ambient Condition Liquid Pipe 1/4 Ø, inch Gas Pipe 1/2 5A Sound LeveL *3) Turbo/Mid/Low dba 36 / 32 / 28 36 / 33 / 31 Net Weight kg 61.0 90.0 Net Dimensions (WxHxD) 1,553 x 270 x 1,000 1,763 x 340 x 1,135 mm Supply/Return/Exhaust/Outside Duct Flange (Ø) 200 250 Air Filter - High Efficiency Filter (PP) Natural Evaporating Type CO 2 Sensor MOS-C1 Virus Doctor MSD-EAN1 OA *4) - 0~40 C DB, 80%RH or less RA *4) - -15~40 C DB, 80%RH or less These products contain Fluorinated greenhouse gas R410A (GWP=2088). Get Fresh Air without Temperature Loss ERV Plus is equipped with a direct expansion coil to pre-condition the outdoor air that enters your indoor environment. Outdoor air will pass through the DX coil to produce fresh air without temperature loss. Smart CO 2 Sensor ERV automatically operates to give fresh air into the room by detecting CO 2 with the CO 2 sensor (optional). *Specifications may be subject to change without prior notice for product improvement. *4) OA: fresh air from outdoor. RA: return air from room. 52 www.samsung.com/uk/dvms

ERV Plus Dimensional Drawing Units: mm VRF INDOOR UNITS Model A B C D E F G H I RHF050KHEA 1036 1000 987 1553 270 99 130 253 135 RHF100KHEA 1183 1135 1189 1763 340 84 160 362 170 Description No. Name 500CMH 1000CMH 1 Liquid pipe connection Ø6.35 Flare 2 Gas pipe connection Ø12.70 Flare 3 Drain pipe connection VP25 (OD32, ID25) 4 Nominal diameter for duct AM050FNKDEH AM100FNKDEH Ø200 Ø250 Samsung Air Conditioning 53

Hydro Unit Specifications 50 o C or 80 o C Hot Water Supply Model Name AM160FNBDEH AM320FNBDEH AM500FNBDEH AM160FNBFEB AM250FNBFEB Type HE (50 o C) HE (50 o C) HE (50 o C) HT (80 o C) HT (80 o C) Performance Nominal Capacity Heating *1) 16.0 31.5 50.4 16.0 25.0 kw Cooling *2) 14.0 28.0 44.8 - VRF INTDOOR UNITS Refrigerant Side Required Flow Rate (Min~Max) 48 92 150 23 36 LPM Flow Switch 20 30 50 12 12 Piping Connections In/Out Ø,.inch 1 11/4 1 1 Piping Connections Liquid 3/8 1/2 3/8 Ø,.inch Gas 5/8 7/8 1.1/8 5/8 Sound Sound Pressure *3) Heating 26. 27. 30. 42. db(a) Cooling 27. 28. 31. - External. Dimension Compressor Electric Specification Weight Net kg 29 33 40 104 Dimensions. (WxHxD) Net mm 518 x 627 x 330 518 x 1,210 x 330 Refrigerant Type - - R-134a R-134a Factory Charging kg - 2.15 (3.07 tco2e) 2.15 (3.07 tco2e) MCA 2.2 24.15 32.15 A Fuse Rating 5 30 40 Operating Range Leaving Water Heating 20~50 25~80 C Cooling 5~30 - These products contain Fluorinated greenhouse gas R410A (GWP=2088) Hydro HT R134a (GWP=1430). DVM Hydro Unit HE (High Efficiency) hot water up to 50 o C Heat pump and Heat recovery (simultaneous cooling and heating) system Air-to-water heating and cooling Consist of DVM outdoor units and hydro unit Cassette-type indoor units are compatible for air-to-air solution Compatible with under floor heating and fan coil units Water temperature up to 50 C Integrated control system DVM Hydro Unit HT (High Temperature) hot water up to 80 o C Heat pump and Heat recovery (simultaneous cooling and heating) system Air-to-water heating Consist of DVM outdoor units, hydro unit and DHW tank Cassette type indoor units are compatible for air-to-air solution Compatible with under floor heating and fan coil units Water temperature up to 80 C Integrated control system Outdoor Indoor Outdoor Indoor Air Heating Air Cooling Air Heating Air Cooling Ref Piping Warm Water Water Piping Under Floor Heating Radiator Ref Piping Hot Water Water Piping Under Floor Heating Radiator Hot Water *Specifications may be subject to change without prior notice for product improvement. *1) Nominal heating capacities are based on; - Water inlet/outlet temperature : 30 C / 35 C; - Outdoor temperature : 7 C DB, 6 C WB *2) Nominal cooling capacities are based on; - Water inlet/outlet temperature : 23 C / 18 C; - Outdoor temperature : 35 C DB 54 www.samsung.com/uk/dvms

Hydro Unit Dimensional Drawing AM160/320/500FNBDEH, AM160/250FBNF*B Units: mm 330 365 Model AM160FNBDEH AM320FNBDEH AM500FNBDEH Refrigerant side Liquid pipe 3/8'' (ø9.52) 1/2'' (ø12.7) Gas pipe 5/8'' (ø15.88) 7/8'' (ø22.23) 1-1/8'' (ø28.58) 340 518 446 599 113 627 45 205 Water side Water inlet/outlet pipe PT 1 (25 A) PT 1-1/4 (32 A) 100 60 Water outlet pipe External contact Gas pipe Communication cable Liquid pipe Power cable Water inlet pipe VRF INDOOR UNITS 73.5 65 90 518 330 42 73 106 246 366 466 1210 365 Power / Communication cable Gas pipe Liquid pipe Water outlet pipe Water inlet pipe 115 333 Model AM160/250FBNF*B Liquid pipe 3/8'' (ø9.52) Refrigerant side Gas pipe 5/8'' (ø15.88) Water side Water inlet/outlet pipe PT 1 (25 A) 340 Samsung Air Conditioning 55

Mode Control Unit (MCU) VRF INTDOOR UNITS Simultaneous Cooling and Heating Indoor units connected to a 3-pipe Heat Recovery outdoor unit can independently heat and cool utilising a Mode Control Unit (MCU). MCUs are available in 4 or 6-port configurations and can be piped together, allowing up to 80 indoor unit connections to a single DVM S system (where specifications allow). MCU indoor/outdoor unit compatible table Model Description Before installing MCU, refer to the compatible table below and find the model before installation. Each MCU requires a 220 240V 1-phase power supply and a drain connection. MCU Kit MCU-S6NEE1N MCU-S4NEE1N MCU-S4NEE2N Below 6 indoor units, below 56 kw (192MBH) Below 4 indoor units, below 56 kw (192MBH) Below 2 large capacity indoor unit, below 56 kw (192MBH) MCU Specification and Installation Model Name MCU-S6NEE1N MCU-S4NEE1N MCU-S4NEE2N Exterior of MCU Number of connectable indoor units Up to 6 units Up to 4 units Up to 2 units. *Refer to the detailed information of installation Maximum capacity of connectable indoor units 56 kw Installation Only units <10kW cooling can be directly connected to one port (liquid and gas pipe) Units with capacity 11.2kW to 14kW must utilise two connection ports via Y-branch connector connected to these MCUs Single units with capacity 11.2kW to 28kW must utilise two connection ports via Y-branch connector 56 www.samsung.com/uk/dvms

MCU Dimensional Drawings MCU-4NEE1N/MCU-6NEE1N Units: mm MCU-Y4NEE1N Weight: 26kg 400mm (Service area for PCB) 400mm (Service area for piping work) 500mm (Service area for piping work) Models MCU-Y4NEE1N/MCU-Y6NEE1N No. Description 1 Liquid pipe connection from outdoor unit (Flare) 700mm (Service area for PCB) 2 High pressure gas pipe connection from outdoor unit (Brazing) 3 Gas pipe connection from outdoor unit (Flange) 4 Liquid pipe connection to indoor units 5 Gas pipe connection to indoor units 6 Condensate drain pipe connection 7 Power and communication wiring conduits VRF INDOOR UNITS MCU-Y6NEE1N Weight: 28kg 400mm (Service area for PCB) 400mm (Service area for piping work) 500mm (Service area for piping work) 700mm (Service area for PCB) Samsung Air Conditioning 57

Outdoor Units Line-up DVM S 60. Heat Recovery 66. Heat Pump 64. Heat Pump Std 2-pipe Heat Pump (HP) or 3-pipe Heat Recovery (HR) Single Module HP 8 10 12 14 16 18 20 22 24 26 28 30 32 Cooling 22.4kW 28.0kW 33.6kW 40.0kW 45.0kW 50.4kW 56.0kW 61.6kW 67.2kW 73.6kW 78.6kW 84.0kW 89.6kW Max. kw Capacity 29.12 36.4 43.7 52.0 58.5 65.52 72.8 80.08 87.4 95.7 102.2 109.2 116.5 Model Capacity Max. no. Indoors 14 18 21 26 29 32 36 40 43 47 51 54 58 AM080JXVHGH/GR 8 HP 1 AM100JXVHGH/GR 10 HP 1 AM120JXVHGH/GR 12 HP 1 2 1 1 1 1 Outdoor Units AM140KXVGGH/ AM140JXVHGR AM160KXVGGH/ AM160JXVHGR AM180KXVGGH/ AM180JXVHGR AM200KXVGGH/ AM200JXVHGR AM220KXVGGH/ AM220JXVHGR 14 HP 1 1 16 HP 1 1 18 HP 1 1 20 HP 1 1 22 HP 1 AM240KXVGGH 24 HP 1 AM260KXVGGH 26 HP 1 VRF OUTDOOR UNITS AM280KXVGGH 28HP 1 AM300KXVGGH 30HP 1 Capacity HP 8 10 12 20 Outdoor Units 71. DVM S Water Phase Cooling 22.4kW 22.0kW 33.6kW 56.0kW Max. kw Capacity 29.12 36.4 43.7 72.8 Max. no. Indoors 14 18 21 36 3 Phase AM080FXWANR AM100FXWANR AM120FXWANR 3 Phase AM200FXWANR Capacity HP 4 5 6 8 10 12 14 Cooling 11.2kW 14.0kW 15.5kW 22.4kW 28kW 33.5kW 40kW Outdoor Units 74. DVM S Eco Phase Max. kw Capacity Max. no. Indoors 14.5 18.2 20.2 29.12 36.4kW 43.6kW 52kW 6 8 9 17 18 21 26 1 Phase AM040FMXDEH AM050FMXDEH AM060FMXDEH 3 Phase AM040FMXDGH AM050FMXDGH AM060FMXDGH AM080FMXDGH AM100KXMDGH AM120KXMDGH AM140KXMDGH 58 www.samsung.com/uk/dvms These products contain Fluorinated greenhouse gas R410A (GWP=2088).

Module Single Module 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 95.2kW 101.6kW 106.6kW 112.0kW 117.6kW 123.2kW 128.8kW 135.2kW 140.2kW 145.6kW 151.2kW 156.8kW 163.2kW 168.2kW 173.6kW 179.2kW 184.8kW 190.4kW 196.8kW 201.8kW 207.2kW 212.8kW 218.4kW 224.8kW 123.8 132.1 138.6 145.6 152.9 160.2 167.4 175.8 182.3 189.3 196.6 203.8 212.3 218.7 225.7 233 240.2 247.5 255.8 262.3 269.4 276.6 283.9 292.2 61 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 1 2 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 2 1 1 1 1 1 1 2 1 1 1 1 1 2 2 2 1 2 3 2 2 2 2 2 3 3 Auto Oil Balancing Samsung DVM S ensures stable and equal oil balancing without requiring an extra oil balancing pipe. Inverter + Inverter Compressor No oil balance pipe Fixed + Inverter Compressor Oil unbalance Balance Pipe is necessary *Please check Eurovent website to confirm exact model certification. VRF OUTDOOR UNITS DVM S Conventional PCB Refrigerant Cooling System By utilising a small amount of refrigerant to cool the PCBs, DVM S ensures better stability than conventional air cooling. DVM S Refrigerant Cooling Method Conventional Air Cooling Method Samsung Air Conditioning 59

DVM S Heat Recovery Specifications High Efficiency Model Name AM080JXVHGR AM100JXVHGR AM120JXVHGR AM140JXVHGR Power Supply, #, V, Hz 3,4,380-415,50 Mode - HEAT RECOVERY Performance HP HP 8.00 10.00 12.00 14.00 Capacity (Nominal) Cooling 22.40 28.00 33.60 40.00 kw Heating 25.20 31.50 37.80 45.00 ESEER 8.00 7.43 7.23 7.12 EER 4.88 4.50 4.44 3.79 COP 5.49 5.35 5.00 4.63 Power Power Input (Nominal) Cooling 1) 4.59 6.22 7.57 10.55 kw Heating 2) 4.59 5.89 4.56 9.72 Max. Current 22.5 29.9 31.3 A Fuse Rating 30 40 Fan Air Flow Rate External Static Pressure Max. CMM 170 220 255 I/s 2833 3667 4250 mmaq 8.00 Pa 78.45 Liquid Pipe 3/8 1/2 VRF OUTDOOR UNITS Piping Connections Refrigerant Gas Pipe, inch 3/4 7/8 1 1/8 Discharge Gas Pipe 5/8 3/4 7/8 Installation Limitation Max. Length 200 (220) m Max. Height 110 (40) R410A (GWP=2088) (tco2e) 13.57 16.08 Factory Charging kg 6.5 6.5 6.5 7.7 Sound 3) External Dimension Sound Pressure 57 58 62 61 db(a) Sound Power 77 79 81 Net Weight kg 206 241 Net Dimensions (WxHxD) mm 880 x 1,695 x 765 1,295 x 1,695 x 765 Operating Temp. Range Cooling -15 ~ 48 C Heating -25.0 ~ 24.0 These products contain Fluorinated greenhouse gas R410A (GWP=2088). Small Footprint and Lighter Weight Large unit capacity (22HP) facilitates the economical installation with a smaller footprint and lighter weight, making it the perfect fit for larger buildings. 26% smaller space Conventional (22HP) Weight: 447kg Space demand:.35m 2 DVM S Weight: 300kg Space demand:.99m 2 whether the PDM kit should be installed or not.) *PDM kit: Pressure Drop Modulation kit 60 www.samsung.com/uk/dvms

AM160JXVHGR AM180JXVHGR AM200JXVHGR AM220JXVHGR 3,4,380-415,50 HEAT RECOVERY 16.00 18.00 20.00 22.00 45.00 50.40 56.00 61.60 50 56.70 63.00 69.30 6.82 6.71 6.66 6.32 4.12 4.38 4.29 3.91 4.69 4.88 4.81 4.37 10.92 11.51 13.05 15.75 10.75 11.62 13.1 15.86 40.0 48.9 52.5 55.6 40 50 75 255 290 4250 4833 8.00 78.45 1/2 5/8 1 1/8 7/8 1 1/8 200 (220) 110 (40) 16.08 17.54 7.7 8.4 8.40 62 63 64 65 VRF OUTDOOR UNITS 82 85 86 88 284.0 306.0 1,295 x 1,695 x 765-15 ~ 48-25.0 ~ 24.0 Versatile Piping Connection with Various Knock-Out Holes The knock-out holes for piping, power and communication cables are located in a variety of directions, allowing for more convenient installation of DVM S since the piping and cable direction can be freely selected from the front, left and right side. unication outlet Side: Communication cable outlet Samsung Air Conditioning 61

DVM S Heat Recovery Dimensional Drawings AM080/100/120JXVHGR High Efficiency Units: mm 7 7 2 1 6 VRF OUTDOOR UNITS 6 8 3 5 4 Any beam supporting the outdoor unit should be mounted along the feet in this direction only 9 No. Name Description 1 Low pressure gas ref. pipe - 2 High pressure gas ref. pipe - Single Installation Over 100 (S2) Front side Front Over 100 side Over 100 Over 100 Over 500 (S1) Over 300 <Case 1> <Case 2> Height of the wall in unlimited 3 Liquid ref. pipe - 4 Power wiring conduit 2 - Ø43.7 5 Communication wiring conduit 2 - Ø34.5 6 Power wiring conduit 4 - Ø43.7 7 Communication wiring conduit 8 - Ø22.0 8 Knock-out hole for ref. piping 178 x 76 9 Anchor bolt hole 4 - Ø12 62 www.samsung.com/uk/dvms

AM140/160/180/200/220JXVHGR Units: mm VRF OUTDOOR UNITS Any beam supporting the outdoor unit should be mounted along the feet in this direction only No. Name Description 1 Low pressure gas ref. pipe - 2 High pressure gas ref. pipe - Module Installation Over 100 Over 100 Front side Over 100 Over 100 Over 300 (S2) Over 500 (S1) Over 200 Over 300 Over 400 Front side Over 400 Height of the wall in unlimited 3 Liquid ref. pipe - 4 Power wiring conduit 2 - Ø43.7 5 Communication wiring conduit 2 - Ø34.5 6 Power wiring conduit 4 - Ø43.7 7 Communication wiring conduit 8 - Ø22.0 8 Knock-out hole for ref. piping 178 x 76 9 Anchor bolt hole 4 - Ø12 <Case 1> <Case 2> Samsung Air Conditioning 63

DVM S Heat Pump Standard Specifications Model Name AM080JXVAGH AM100JXVAGH AM120JXVAGH AM140KXVAGH AM160KXVAGH Power Supply, #, V, Hz 3,4,380-415,50 Mode - HEAT PUMP Performance HP HP 8.00 10.00 12.00 14.00 16.00 Capacity (Nominal) Cooling 22.40 28.00 33.60 40.0 45.0 kw Heating 25.20 31.50 37.80 45.0 50.4 ESEER 7.85 7.25 7.03 7.02 6.81 EER 4.48 4.09 4.12 3.66 3.72 COP 4.94 4.74 4.71 4.43 4.34 Power Power Input (Nominal) Cooling 1) 5.00 6.85 8.16 10.93 12.10 kw Heating 2) 5.10 6.65 8.03 10.16 11.61 Max. Current 22.5 29.9 31.3 25.0 32.0 A Fuse Rating 30 40 32 40 Fan Air Flow Rate External Static Pressure Max. CMM 170 220 255 I/s 2,833 3,667 4,250 mmaq 8.00 Pa 78.45 VRF OUTDOOR UNITS Piping Connections Refrigerant Sound 3) Liquid Pipe 3/8 1/2, inch Gas Pipe 3/4 7/8 1 1/8 Installation Limitation Max. Length 200 (220) m Max. Height 110 (40) R410A (GWP=2088) (tc02e) 11.48 13.57 16.08 17.54 Factory Charging kg 5.50 6.5 7.7 8.4 Sound Pressure 57 58 62 61 63 db(a) Sound Power 77 79 81 81 83 External Dimension Net Weight kg 186 197 210 253 253 Net Dimensions (WxHxD) mm 880 x 1,695 x 765 1295 x 1695 x 765 1295 x 1695 x 765 Operating Temp. Range Cooling -5.0 ~ 48.0 C Heating -25.0 ~ 24.0 These products contain Fluorinated greenhouse gas R410A (GWP=2088). Optimised Refrigerant Distribution Control Since piping distance can be considerable between outdoor and indoor units, the individual indoor units perform capacity connection control and automatic refrigerant balancing to secure balanced performance between the units. P P P (Pipe (pipe pressure loss) loss) Auto pressure correction h PDM kit installation Guide software whether the PDM kit should be installed or not.) *PDM kit: Pressure Drop Modulation kit 64 www.samsung.com/uk/dvms

AM180KXVAGH AM200KXVAGH AM240KXVAGH AM240HXVAGH AM260KXVAGH AM280KXVAGH AM300KXVAGH 3,4,380-415,50 HEAT PUMP 18.00 20.00 22.00 24.00 26.00 28.00 30.00 50.4 56.0 61.6 67.2 72.8 78.6 84.0 56.7 63.0 69.3 75.6 81.9 88.2 94.5 6.61 6.56 6.25 7.18 6.92 6.83 6.65 4.00 3.95 3.55 4.20 3.85 3.80 3.70 4.76 4.53 4.15 4.90 4.55 4.37 4.59 12.60 14.18 17.35 16.00 18.91 20.68 22.70 11.91 13.91 16.70 15.43 18.00 20.18 20.59 39.2 42.0 44.6 55.0 60.0 67.0 73.0 50 63 75 290 340 4833 8.00 78.45 5/8 3/4 1 1/8 1 3/8 200 (220) 110 (40) 17.54 29.23 8.4 8.4 8.4 14.0 14.0 14.0 64 65 65 66 69 69 84 87 89 89 90 90 VRF OUTDOOR UNITS 255 277 285 333 342 350.0 1295 x 1695 x 765 1295 x 1795 x 765 1295 x 1795 x 765-5.0 ~ 48.0-25.0 ~ 24.0 Refrigerant Pump-down and Pump-out DVM S provides the refrigerant pump-down/ out functions to facilitate easy and convenient replacement of the product, as well as additional installations and maintenance. In case of outdoor unit maintenance, it is possible for the refrigerant to recover into indoor units and pipes. It is also possible to recover refrigerant into outdoor units when moving indoor units or performing maintenance on pipes. Refrigerant Pump-out Function High External Static Pressure To properly deal with unexpected and varying installation conditions, DVM S is designed to manage high external static pressures up to 78.45 Pa. 78.45 Pa Refrigerant Pump-down Function Samsung Air Conditioning 65

DVM S Heat Pump High Efficiency Specifications Model Name AM080JXVHGH AM100JXVHGH AM120JXVHGH AM140KXVGGH AM160KXVGGH Power Supply, #, V, Hz 3,4,380-415,50 Mode - HEAT PUMP Performance HP HP 8.00 10.00 12.00 14.00 16.00 Capacity (Nominal) Cooling 22.40 28.00 33.60 40.00 45.00 kw Heating 25.20 31.50 37.80 45.00 50.40 ESEER 8.00 7.43 7.23 7.78 7.38 EER 4.88 4.50 4.44 4.50 4.12 COP 5.49 5.35 5.00 4.68 4.69 Power Power Input (Nominal) Cooling 1) 4.59 6.22 7.57 8.89 10.92 kw Heating 2) 4.59 5.89 4.56 15.40 17.20 Max. Current 22.5 29.9 31.3 25.0 32.0 A Fuse Rating 25 32 40 Fan Air Flow Rate External Static Pressure Max. CMM 170 220 255 255 I/s 2,833 3,667 4,250 4,250 mmaq 8.00 Pa 78.45 VRF OUTDOOR UNITS Piping Connections Refrigerant Sound 3) Liquid Pipe 3/8 1/2, inch Gas Pipe 3/4 7/8 1 1/8 Installation Limitation Max. Length 200 (220) m Max. Height 110 (40) R410A (GWP=2088) (tco2e) 13.57 19.63 17.54 Factory Charging kg 6.5 6.5 6.5 9.4 8.4 Sound Pressure 57 58 62 61 63 db(a) Sound Power 77 79 81 83 External Dimension Net Weight kg 206 241 255 Net Dimensions (WxHxD) mm 880 x 1,695 x 765 1295 x 1695 x 765 Operating Temp. Range Cooling -5.0 ~ 48.0 C Heating -25.0 ~ 24.0 These products contain Fluorinated greenhouse gas R410A (GWP=2088). Optimised Refrigerant Distribution Control Since piping distance can be considerable between outdoor and indoor units, the individual indoor units perform capacity connection control and automatic refrigerant balancing to secure balanced performance between the units. P Auto pressure correction h P P (Pipe (pipe pressure loss) loss) PDM kit installation Guide software whether the PDM kit should be installed or not.) *PDM kit: Pressure Drop Modulation kit 66 www.samsung.com/uk/dvms

AM180KXVGGH AM200KXVGGH AM220KXVGGH AM240KXVGGH AM260KXVGGH AM280KXVGGH AM300KXVAGH 3,4,380-415,50 HEAT PUMP 18.00 20.00 22.00 24.00 26.00 28.00 30.00 50.40 56.00 61.60 67.20 72.80 78.60 84.00 56.70 63.00 69.30 75.60 81.90 88.20 94.50 7.25 6.82 6.43 7.18 7.17 6.86 6.65 4.72 4.48 3.91 4.20 4.20 4.00 3.70 5.39 4.94 4.37 4.90 4.80 4.70 4.59 10.68 12.50 15.75 16.00 17.33 19.65 22.70 16.9 12.75 15.86 15.43 17.06 18.77 20.59 39.2 42.0 44.6 55.0 60.0 67.0 73.0 50 63 63 63 75 290 340 4,833 8.00 78.45 5/8 3/4 1 1/8 1 3/8 200 (220) 110 (40) 17.54 29.23 8.40 14.0 65 65 65 69 69 69 69 89 89 89 90 90 90 90 VRF OUTDOOR UNITS 285 342 350 350 350 1295 x 1695 x 765 1295 x 1795 x 765-5.0 ~ 48.0-25.0~ 24.0 Refrigerant Pump-down and Pump-out DVM S provides the refrigerant pump-down/ out functions to facilitate easy and convenient replacement of the product, as well as additional installations and maintenance. In case of outdoor unit maintenance, it is possible for the refrigerant to recover into indoor units and pipes. It is also possible to recover refrigerant into outdoor units when moving indoor units or performing maintenance on pipes. Refrigerant Pump-out Function High External Static Pressure To properly deal with unexpected and varying installation conditions, DVM S is designed to manage high external static pressures up to 78.45 Pa. 78.45 Pa Refrigerant Pump-down Function Samsung Air Conditioning 67

DVM S Heat Pump High Efficiency Dimensional Drawings AM080/100/120JXVHGH Units: mm VRF OUTDOOR UNITS Any beam supporting the outdoor unit should be mounted along the feet in this direction only No. Name Description 1 Gas ref. pipe - Single Installation Over 100 (S2) Front side Front Over 100 side Over 100 Over 100 Over 500 (S1) Over 300 <Case 1> <Case 2> Height of the wall in unlimited 2 Liquid ref. pipe - 3 Power wiring conduit 2 - Ø43.7 4 Communication wiring conduit 2 - Ø34.5 5 Power wiring conduit 4 - Ø43.7 6 Communication wiring conduit 8 - Ø22.0 7 Knock-out hole for ref. piping 178 x 76 8 Anchor bolt hole 4 - Ø12 68 www.samsung.com/uk/dvms

AM140/160/180/200/220/KXVGGH Units: mm VRF OUTDOOR UNITS Any beam supporting the outdoor unit should be mounted along the feet in this direction only No. Name Description 1 Gas ref. pipe - Module Installation 2 Liquid ref. pipe - 3 Power wiring conduit 2 - Ø43.7 Over 100 Over 100 Front side Over 100 Over 100 Over 300 (S2) Over 500 (S1) Over 200 Over 300 Over 400 Front side Over 400 Height of the wall in unlimited 4 Communication wiring conduit 2 - Ø34.5 5 Power wiring conduit 4 - Ø43.7 6 Communication wiring conduit 8 - Ø22.0 7 Knock-out hole for ref. piping 178 x 76 8 Anchor bolt hole 4 - Ø12 <Case 1> <Case 2> Samsung Air Conditioning 69

DVM S Heat Pump High Efficiency Dimensional Drawings AM240/260/280/300KXVGGH Units: mm/inches VRF OUTDOOR UNITS 70 www.samsung.com/uk/dvms

DVM S Water Specifications Model Name AM080FXWANR AM100FXWANR AM120FXWANR AM200FXWANR Power Supply, #, V, Hz 3,4,380-415,50/60 Mode - HEAT PUMP AND HEAT RECOVERY HP HP 8.00 10.00 12.00 20.00 Performance Capacity (Nominal) Cooling 22.40 28.00 33.60 56.00 kw Heating 25.20 31.50 37.80 63.00 EER 5.83 5.54 5.20 COP 6.12 6.00 5.81 5.80 Power COP Power Input (Nominal) Cooling 1) 3.84 5.05 6.46 8.89 kw Heating 2) 4.12 5.25 6.51 9.37 Max. Current 16.30 (MCA) 20.00 (MCA) 25.00 (MCA) 36.30 (MCA) A Fuse Rating 20 32 40 Nominal Cooling 1) - 5.83 5.54 5.20 5.67 Nominal Heating 2) - 6.12 6.00 5.81 6.05 Type - PHE (Stainless Steel Plate) Pipe Size, inch PT 1-1/4 PT 1-1/4 x 2 Condenser Lost Head kpa 22.0 30.0 43.0 54.0 Water Flow Rate LPM 80.0 96.0 114.0 190.0 Max. Pressure Mpa 1.96 Piping Connections Refrigerant Liquid Pipe 3/8 1/2 5/8 Discharge Gas Pipe, inch 5/8 3/4 1 1/8 Gas Pipe 3/4 7/8 1 1/8 Installation Limitation Max. Length 170 (190) m Max. Height 50.0 (40.0) R410A (GWP=2088) (tco2e) 11.48 12.11 12.53 20.46 Factory Charging kg 5.50 5.80 6.00 9.80 VRF OUTDOOR UNITS Sound 3) External Dimension Sound Pressure 48.0 50.0 51.0 db(a) Sound Power 70.0 73.0 Net Weight kg 160.0 240.0 Net Dimensions (WxHxD) mm 770 x 1,000 x 545 1,100 x 1,000 x 545 Operating Temp. Range Cooling 10.0 ~ 45.0 C Heating 10.0 ~ 45.0 For combinations up to 60HP, please contact your local Samsung dealer. These products contain Fluorinated greenhouse gas R410A (GWP=2088). Saving Installation Space DVM S Water is much more economical to install as it has a small footprint and lightweight design, but a large 20 horsepower (HP) capacity. So instead of installing two 10HP units, you only need one 20HP Samsung unit using 30% less space and significantly reducing the costs of valves, fittings and gauges. You can also combine up to three units to create a total capacity of 60HP. Optimal Water Flow Controller DVM S Water s built-in Water Flow Controller helps control the amount of water used to cool and heat the outdoor unit. It determines the optimum flow of water based on the internal temperature of the spaces, so the circulation pump s energy consumption is optimised and costs reduced. And because it s provided as standard, there s no need to buy a separate water flow control kit. Specifications may be subject to change without prior notice for product improvement. 1) Nominal cooling capacities are based on; Indoor temperature : 27 C DB, 19 C WB / Inlet water temperature : 30 C / Equivalent refrigerant piping : 7.5m, Level differences : 0m 2) Nominal heating capacities are based on; Indoor temperature : 20 C DB, 15 C WB / Inlet water temperature : 20 C / Equivalent refrigerant piping : 7.5m, Level differences : 0m 3) Sound level was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions. Samsung Air Conditioning 71

DVM S Water Dimensional Drawings AM080/100/120FXWANR Units: mm VRF OUTDOOR UNITS Module or Continuous Installation Outdoor unit Outdoor unit B 300 Model Name of Outdoor Unit A B C AM080/100/120FXWA 770 AM200FXWA 1100 545 600 20 350 Service space Front side A 100 350 Service space Front side A 100 C <Top view> 72 www.samsung.com/uk/dvms

AM200FXWANR Units: mm No. Name Description 1 Liquid ref. pipe 15.88 (5/8'') 2 High pressure gas ref. pipe 28.58 (1 1/8'') 3 Low pressure gas ref. pipe 28.58 (1 1/8'') 4 Water outlet pipe PT 1-1/4 5 Water inlet pipe PT 1-1/4 6 External contact wiring - 7 Communication wiring - 8 Power wiring - VRF OUTDOOR UNITS Module or Continuous Installation Outdoor unit Outdoor unit B 300 Model Name of Outdoor Unit A B C AM080/100/120FXWA 770 AM200FXWA 1100 545 600 20 350 Service space Front side A 100 350 Service space Front side A 100 C <Top view> Samsung Air Conditioning 73

DVM S Eco Specifications Model Name AM040FXMDEH (DGH) AM050FXMDEH (DGH) AM060FXMDEH (DGH) Power Supply, #, V, Hz 1,2,220-240,50 (3,4,380-415,50) Mode - HEAT PUMP Performance HP HP 4.00 5.00 6.00 Capacity (Nominal) Cooling 12.10 14.00 15.50 kw Heating 13.50 16.00 18.00 SEER 6.85 6.24 5.75 EER 4.18 3.80 3.60 COP 4.46 4.43 4.10 Power COP Power Input (Nominal) Cooling 1) 2.89 3.69 4.31 kw Heating 2) 3.02 3.60 4.40 Max. Current 22.00 (MCA) (10/ph) 24.00 (MCA) (12/ph) 32.00 (MCA) (12/ph) A Fuse Rating 32 (16/ph) 40 (25/ph) Nominal Cooling - 4.19 3.79 3.60 Nominal Heating - 4.47 4.44 4.09 Fan Air Flow Rate CMM 110 100 I/s 1,833 1,666 VRF OUTDOOR UNITS Piping Connections Refrigerant Liquid Pipe Gas Pipe Installation Limitation, mm - - -, inch 3/8", mm - - -, inch 5/8" 3/4" Max. Length 150 (175) m Max. Height 50.0 (40.0) R410A (GWP=2088) (tco2e) 6.68 6.89 Factory Charging kg 3.20 3.30 Sound 3) External Dimension Sound Pressure 50.0 51.0 53.0 db(a) Sound Power 66.0 67.0 69.0 Net Weight kg 100.0 103.0 Net Dimensions (WxHxD) mm 940 x 1,210 x 330 Operating Temp. Range Cooling -5.0 ~ 48.0 C Heating -20.0 ~ 26.0 These products contain Fluorinated greenhouse gas R410A (GWP=2088). Specifications may be subject to change without prior notice for product improvement. 1) Nominal cooling capacities are based on; Indoor temperature : 27 C DB, 19 C WB / Inlet water temperature : 30 C / Equivalent refrigerant piping : 7.5m, Level differences : 0m 2) Nominal heating capacities are based on; Indoor temperature : 20 C DB, 15 C WB / Inlet water temperature : 20 C / Equivalent refrigerant piping : 7.5m, Level differences : 0m 3) Sound level was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions. 74 www.samsung.com/uk/dvms

AM080FXMDGH AM100KXMDGH AM120KXMDGH AM140KXMDGH 3,4,380-415,50 HEAT PUMP 8.00 10.00 12.00 14.00 22.40 28.00 33.50 40.00 25.00 31.50 37.50 45.00 6.22 7.09 6.94 6.83 3.92 3.84 3.82 3.78 5.12 4.67 4.79 4.55 5.72 7.29 8.77 10.59 4.88 6.74 7.83 9.88 18.00 (MCA) 21.50 23.50 32 25 30 30 40 3.92 5.12 135 165 166 180 2,250 2750 2767 3000 - - - - 3/8" 3/8" 1/2 - - - - 3/4" 7/8 1 1/8 100 (100) 160 (185) 30.0 (30.0) 50 (40) 7.73 8.98 10.02 3.70 3.70 4.30 4.80 VRF OUTDOOR UNITS 56.0 58.0 59.0 62.0 74.0 74.0 76.0 79.0 135.0 145.0 155.0 162.0 940 x 1420 x 330 940 x 1630 x 460-5.0~48.0-20.0 ~ 24.0 '-25.0~24.0 Small in Size and Weight. Big on Choice and Efficiency The DVM S Eco air conditioning system is a compact and efficient outdoor unit that s suitable for a wide range of homes and small businesses. It s available in a wide choice of capacities and also features a compact and lightweight design, making it very easy and economical to install and use. And it s also extremely quiet, so whatever your needs, you can enjoy optimum efficiency and comfort anywhere. DVM S Eco Conventional Samsung Air Conditioning 75

DVM S Eco Dimensional Drawings AM040/050/060FXMDEH, AM040/050/060FXMDGH 940 Units: mm 330 25 360 384 4-Ø12 VRF OUTDOOR UNITS 558 567 885 1185 1210 620 No. Name Description 1 Gas ref. pipe Ø, mm 12.1, 14.0 kw : 15.88, 15.5 kw : 19.05 2 Liquid ref. pipe Ø, mm 9.52 3 4 Condensate drain holes Power and communication wiring holes Ø, mm 20 x 4 Ø, mm 22.2 x 3 / 34.5 x 3 When installing 1 outdoor unit When installing 1 outdoor unit When the air outlet is opposite the wall 300 or more When the air outlet is toward the wall 1500 or more When 3 sides of the outdoor unit are blocked by the wall 300 or more When 3 sides of the outdoor unit are blocked by the wall 300 or more 150 or more 600 or more The upper part of the outdoor unit is blocked and the air outlet is toward the wall 2000 or more 1500 or more 300 or more 600 or more 600 or more 600 or more When the walls are blocking front and the rear of the outdoor units 600 or more 600 or more 1500 or more 300 or more When front and rear side of the outdoor unit is toward the wall 1500 or more 600 or more 3000 or more 3000 or more 300 or more 76 www.samsung.com/uk/dvms

AM080FXMDGH, AM100/120/140KXMDGH Units: mm No. Name 1 Refrigerant gas pipe 2 Refrigerant liquid pipe 3 Drain hole 4 Power and communication wiring conduits VRF OUTDOOR UNITS No. AM100/120/140KXMDGH 1 Refrigerant gas pipe 2 Refrigerant liquid pipe 3 Drain hole 4 Power and communication wiring conduits Samsung Air Conditioning 77

Piping Diagram DVM S Heat Recovery Heat Recovery DVM S systems utilise MCU boxes to facilitate the connection of the 3-pipe outdoor units to the liquid and gas connection on each indoor unit. The piping restrictions as shown below must be used in conjunction with the correct pipe sizing table as detailed in the installation manual. Alternatively, use the DVM Pro design programme to produce a project-specific piping schematic. Multiple outdoor units and MCU boxes are connected via branch pipe kits (installed horizontally) to facilitate the connection of the 3-pipe outdoor units to the liquid and gas connection on each indoor unit. The piping restrictions as shown below must be used in conjunction with the correct pipe sizing table as detailed in the installation manual. Alternatively, use the DVM Pro design programme to produce a project-specific piping schematic. MCU VRF OUTDOOR UNITS MCU MCU Note: To allow for increased pipe lengths from first branch, the pipes must be increased by one size. Height differences between outdoor and indoor over 50m must utilise a PDM kit. Please contact your local Samsung dealer for more details. 78 www.samsung.com/uk/dvms

Piping Diagrams DVM S Eco DVM S Heat Pump The 2-pipe Heat Pump DVM S systems utilise branch pipe kits (installed horizontally) to connect outdoor unit to the liquid and gas connection on each indoor unit. The piping restrictions as shown below must be used in conjunction with the correct pipe sizing table as detailed in the installation manual. Alternatively, use the DVM Pro design programme to produce a project-specific piping schematic. Multiple outdoor units are connected via branch pipe manifold kits. The piping restrictions as shown below must be used in conjunction with the correct pipe sizing table as detailed in the installation manual. Alternatively, use the DVM Pro design programme to produce a project-specific piping schematic. VRF OUTDOOR UNITS Note: To allow for increased pipe lengths from first branch, the pipes must be increased by one size. Height differences between outdoor and indoor over 50m must utilise a PDM kit. Please contact your local Samsung dealer for more details, Samsung Air Conditioning 79

Piping Diagram DVM S Water Heat Pump Heat Recovery DVM S Water system is manufactured as a combined Heat Pump/ Heat Recovery system. The HR systems utilise MCU boxes to facilitate the connection of the 3-pipes to the liquid and gas connection on each indoor unit. 2-pipe Water Heat Pump DVM S systems utilise branch pipe kits (installed horizontally) to connect the outdoor unit to the liquid and gas connection on each indoor unit. The piping restrictions as shown below must be used in conjunction with the correct pipe sizing table as detailed in the installation manual. Alternatively, use the DVM Pro design programme to produce a project-specific piping schematic. MCU VRF OUTDOOR UNITS MCU Note: To allow for increased pipe lengths from first branch, the pipes must be increased by one size. 80 www.samsung.com/uk/dvms

Wiring Diagram DVM S Eco DVM S Water DVM S Heat Pump DVM S Heat Recovery The wiring for all DVM S systems follow the same configuration of separate fused power supplies for outdoor and indoor units, which are connected via a non-polar 2-core communication wire. All wiring must be installed as detailed in the installation manual. Alternatively, use the DVM Pro design programme to produce a project-specific wiring schematic. Individual controllers are wired directly to the indoor units and high level central controls are connected directly to the outdoor unit (the touch controller can be connected to either). Connection MIM-N01 to control previous generation DVM systems S-NET3 PC Software 3 phase 380 415V MCCB+ ELB For HR MCU Connection only 1 phase 220 240V from outdoor R1 R2 F1 F2 Outdoor Communication Central Control Comms Layer FS FS FS R1 R2 R1 R2 R1 R2 MCM-A202DN MCM-A300N MIM-D00AN or MIMB-17N or MIM-B18N FS MIM-B16 Power Monitoring MCCB+ ELB 1 phase 220-240V VRF OUTDOOR UNITS MCU F1 F2 FS MCCB+ ELB 1 phase 220 240V FS F1 F2 F3 F4 FS F3 F4 FS FS F1 F2 F3 F4 F3 F4 up to 16 indoors on 1 remote FS F3 F4 FS F1 F2 MCM-A300N 2 remotes to 1 indoor Comms Layer MWR-SH00N MWR-WE10N MWR-WE10N MWR-WE10N MWR-WE10N Individual Control Comms Layer Connection to external contact signal MIM-B14 Note: All power supplies, fuses, breakers and communication wiring must be selected and installed using local regulations and specifications. Always check the power wires are properly connected prior to switching on to avoid damage to electrical components. Samsung Air Conditioning 81

Controls Line-up Classification Model Code Image Description Application MR-DH00 AR-KH00E Wireless Remote Controller Heat pump wireless controller for use on all units with infrared receivers MWR-WE10N Full function wired controller for use with all indoor units, ERV and AHU MWR-SH10N Wired Remote Controller Touch screen, simplified wired controller for use in hotel applications Individual Control MWR-SH00N Simplified wired controller for use in hotel applications MRK-A10N Wireless Signal Receiver Ducted unit wireless receiver unit MIM-H03N Wi-Fi Controller Wi-Fi module to control units from afar using mobile device MRW-TA External Remote Temp. Sensor External room sensor with 12m lead Centralised Control MCM-A300N Centralised Controller Touch-screen central controller full function up to 64 indoor units MIM-D01AN DMS 2.5 Programmable Mini BMS 256 indoor units, full control, inputs/outputs Building Management MST-P3P S-NET 3 PC web server to control and monitor up to 4,096 units via DMS2 modules MIM-B18BN Lonworks G/W DMS2 with built-in Lonworks BMS gateway MIM-B17BN BACnet G/W DMS2 with built-in BACnet BMS gateway Power Monitoring MIM-B16N MCM-C210N Electricity Meter Power Monitoring Power monitoring module for DMS2 up to 8 Watt/hr meters To allow individual VRF unit power interruption without error, i.e., hotel bedrooms, apartments CONTROLS External Contact Interface MIM-B14 External Contact Interface On/Off operation control and Run/Fault indication interface Converter MIM-N01 and MIM-N10 NASA Converter Interface previous generation RS485 communication protocol with current NASA protocol MIM-C02N S-Net Converter Diagnostic software interface 82 www.samsung.com/uk/dvms

Individual Control Wireless Remote Controller MR-DH00 AR-KH00E (360 cassette) Simple schedule control Individual blade control for 4way cassette models Multi-channel wireless remote control (maximum 4 channels) Wired Remote Controller MWR-WE10N Individual and group control (maximum 16 indoor units) Error display Built-in Room Temperature sensor Automatic stop mode Wireless remote control restriction Unified controller (AC, ERV, ERV PLUS, AHU) Weekly schedule setting (A/C, ERV, A/C+ERV) Exception date setting Individual blade control for 4way cassette models MWR-WW00N (for DVM S Hydro) INDIVIDUAL CONTROL Simplified Wired Remote Controller MWR-SH00N/MWR-SH10N Individual and group control (maximum 16 indoor units) Error display Mode selection protection Touch screen control (MWR-SH10N) Wi-Fi Control Module MIM-H03N Control via mobile app (available to download) 7-Day schedule setting Energy monitoring Wireless Signal Receiver MRK-A10N Operation indication Error indication Filter replacement sign Use with receiver wire, MRW-10A CONTROLS External Room Sensor MRW-TA External sensor to sense exact user environment temperature Wire length: 12m Samsung Air Conditioning 83

Centralised Control CENTRALISED CONTROL Touch Centralised Controller MCM-A300N 7-inch Colour Capacitive Touch Screen Easy and Intuitive UI Individual/Zone control, Scheduling, Energy saving control Emergency operation control by external contact Control up to 128 indoor units DS card for programming and data download Easy and Intuitive UI Various icons based on equipment and operation condition Smart phone style user-friendly control Individual/group management Control and Monitoring Easy to check each device s status using colour and icon Large-size icons for ease of use High and low temperature limitation settings Individual unit restriction settings Zone Management for multiple units Manage up to 12 zones Simply control zones with one button Set unique zone description icons to easily recognise each zone Easily bind multiple indoor units to create a zone CONTROLS Schedule Control Set up to 10 operation schedules Apply these schedules to any unit or zone Create operation events for each schedule, including: temperature setting, mode and fan speed 84 www.samsung.com/uk/dvms

Building Management Server DMS 2.5 (Data Management Server) MIM-D01AN The improved Data Management Server has become smarter: it newly upgraded functions can automatically manage the air conditioning system for you. Built-in web server for PC-independent management and remote access control Multiple upper-level control access (S-NET 3, S-NET Mini, Web-client) Central management of up to 256 indoor units including ERV, ERV PLUS and AHU User-editable control logic Accessible level management Dynamic security management Operation and error history management Weekly/Daily schedule control Power distribution function Current time management even during power failure (for 24 hours) Data storage in non-volatile memory and SD memory Emergency stop function with simple contact interface 8 External inputs and 6 outputs provide control and monitoring for third-party devices BUILDING MANAGEMENT Enhanced Graphical display User-friendly icon-based unit control Color indication and icons make it easy to recognise indoor unit status CONTROLS Convenient and stylish controller Zoom in and Zoom out icon display Samsung Air Conditioning 85

Building Management Server BUILDING MANAGEMENT DMS 2.5 Mini-BMS Programmable Control Logic The user can control the air conditioning, ERV, AHI and digital outputs using an arithmetic equation and conditional operators/parameters from the equipment operating conditions including volt-free inputs from external equipment Control logic can utilise the 8 external inputs and 6 outputs, permitting interaction between air conditioning and third-party devices Using this powerful functionality, energy can be efficiently used and reduced for various operation conditions Room Outdoor WINTER SUMMER Logic Outdoor temp < Room temp Room temp < Outdoor temp Control Turn ON ERV (Cool air Intake UP) Turn ON Air Conditioner Outdoor temp < 10 Outdoor temp > 25 Heating mode Cooling mode EHP / ERV / AHU Parameters Arithmetic Equation Function EHP / ERV / AHU Parameters change AND Temperature, Power, Mode OR <, >, =, =>, =<, Average Setting temperature, Power, Mode, Fan speed *Example: Energy saving function, operation adjustment depending on outdoor temperature. Easy Control and Monitoring Control and monitoring of up to 256 indoor units via internet network Operation mode, fan speed, temperature setting ERV, ERV PLUS, AHU support DMS 2 Anytime, Anywhere Control CONTROLS Specification Attribute/Function Indoor Unit Connection (Max.) 256 Indoor Units (128 per channel) Outdoor Unit Connection (Max.) 80 Outdoor Units Indoor Unit Control - All Indoors, ERV, AHU Dimensions (WxHxD) mm 240 x 255 x 65 Power - 100 240V AC (DC adaptor) Lower Level RS485 (to Outdoor/PIM) Communication Upper Level Ethernet 100 Base-T (web browser) Direct Interface - LCD Display (4 soft keys), LED Indicators PIM Connection (MIM-B16) (Max.) 8 Touch Screen Connection (MCM-A300N) (Max.) 16 Emergency Stop - Pulse or Level Input Inputs (Max.) 8 Volt-free (Open/Short) Outputs (Max.) 6 Contact Signal (12V) - 3 Logic Functions (per input) Programmable Logic (per condition) Boolean logic - 20 Output Logic Factors 86 www.samsung.com/uk/dvms

Building Management Server DMS 2.5 Features Powerful Data Backup DMS 2 records indoor unit operation and error occurrence history Recorded history makes it convenient to analyse air-conditioner operation and perform unit maintenance Important data is safely stored on SD memory card: 1. Indoor/outdoor unit name 2. Power distribution data 5. System configuration 6. Others Automatic System Recovery after Service Operation History 2. Daily accumulated operation On time 3. Schedule operation execution time Error History 1. Error occurred unit name 2. Error details 3. Error occurrence/clear time 4. Error state (solved/unsolved) BUILDING MANAGEMENT Rapid and Easy Service Response Remote control and monitoring through the internet (if public IP is used) Email notification to private internet account in case of malfunction Malfunction email Remote Service DMS 2 Dynamic User Security Management It is possible to specify the scope of control and monitoring unit by each user General users, managers, and administrators can be registered separately by ID and password Administrators (utility managers) have the authority to set access levels for DMS 2 functions on users Administrator Each user can only control and monitor the units they are allowed to access. User A User B User C Admin Manager User Functions Access All Changeable Control / Monitoring O O O Zone Management O O X Schedule O O O Power Distribution O O X System Configuration O X X User D CONTROLS Samsung Air Conditioning 87

Building Management Power Monitoring Power Distribution System Indoor Unit Operation State POWER MONITORING Power distribution to a maximum of 256 indoor units Data query for watt-hour, usage time and usage ratio Files are saved in Microsoft Excel format 1-year power distribution data is saved in storage Current actual power consumption monitoring Current-type electricity meter support (CT ratio input) 1. Operation Data Accumulation and Power Distribution 5 th Floor 140kWh 4 th Floor 610kWh 3 rd Floor 460kWh 2 nd Floor 360kWh 1 st Floor 180kWh 2. Data Extract Excel Format Watt-hour Meter Interface Module MIM-B16 PIM (Pulse Input Module) Watt-hour Meter Interface Module can be exclusively used for DMS 2 power distribution, displaying power consumption for each watt-hour meter. Exclusive use for DMS 2 power distribution Connection with up to 8 watt-hour meters Pulse interface with watt-hour meters Power consumption display for each watt-hour meter Connection Supports Max.8 PIM Centralised Control DMS 2 CONTROLS Supports Max.8 watt-hour meters Outdoor Unit Indoor Unit 88 www.samsung.com/uk/dvms

Building Management Gateways A DMS 2.5 with built-in BACnet or LonWorks gateways (all the features of a DMS2, plus interface to your chosen BMS). BACnet Gateway MIM-B17BN (DMS-Bnet) With the BMS control and monitoring function, BACnet gateway makes it easy to control the air conditioning network in various ways. It can control up to 256 indoor units, used in combination with S-NET 3 and MCM-A300N. Interface for BACnet management system Maximum 256 indoor units plus ERVs support with a maximum of 80 interface modules Includes DMS 2 functions Features for BACnet and LonWorks Gateways Control Filter alarm reset Operation mode User control restriction Temperature setting Operation mode lock Fan speed/direction Set temperature limit ERV operation mode Emergency stop ERV fan speed Output contact control BUILDING MANAGEMENT LonWorks Gateway MIM-B18BN (DMS-Lnet) LonWorks gateway is an interface for Lon-Connection to LonWorks management system, providing a more convenient way to manage your air conditioning system. It can control a maximum of 128 indoor units, used in combination with S-NET 3 and MCM-A300N. Monitoring Operation mode Set/Room temperature Fan speed/direction ERV operation mode ERV fan speed Thermo On/Off Power distribution Operation mode lock Set temperature limit In/Out contact state Emergency stop Interface for Lon-Connection to LonWorks management system Maximum 128 indoor units plus ERVs support with a maximum of 80 interface modules Includes DMS 2 functions Filter alarm User control restriction Error code Connections BACnet BMS LonWork BMS RS485 Ethernet FTT-10A CONTROLS Samsung Air Conditioning 89

Web Server External Contact Interface CONTROLS EXTERNAL CONTACT INTERFACE BUILDING MANAGEMENT Web Server, S-NET 3 MST-P3P A PC programme designed to manage an estate of air conditioning systems via DMS2 Data Management Servers. Fully integrated PC management software Up to 16 DMS 2 connection through the ethernet Central management of up to 4,096 indoor units including ERV, ERV PLUS and AHU Schedule/Zone control Error/Operation history management Power distribution management and analysis External Contact Interface MIM-B14 Direct indoor unit control by external contact signal Window-synchronised indoor unit control Emergency control with simple contact input Indoor unit operation/error state output through relay contacts Guestroom Management Module Guest Room Management system saves you energy and money on cooling an unoccupied room: The air conditioner Key-Tag is removed. Example (Wall-mounted type Indoor Units: only models that include EEV support state output function) Key-Tag Error Window Open Sensor Malfunction Alarm External Device Control 90 www.samsung.com/uk/dvms

Air-to-Air Heat Exchangers ERV Model Name AN026JSKLKN AN035JSKLKN AN050JSKLKN AN080JSKLKN AN100JSKLKN Air Volume (m 3 /hr) 260 350 500 800 1000 Air Flow Rate (l/s) high/low 72 / 50 97 / 71 139 / 100 222 / 156 278 / 192 Temperature exchange efficiency 70% Static Pressure (Pa) turbo/high/low 100 / 65 / 55 155 / 100 / 83 165 / 100 / 85 155 / 90 / 80 155 / 90 / 75 Sound Pressure (db(a)) high/low 31 / 22 32 / 23 35 / 24 36 / 25 37 / 26 Dimensions WxHxD mm 600 x 350 x 660 1012 x 270 x 1000 1220 x 340 x 1135 Weight kg 28.5 42.5 67 OTHER NEW PRODUCTS Spigot dimensions (mm - diameter) 150 200 200 250 250 *All models: 1ph 220-240V power supply (5A). Controls Control options include: MWR-VH12N Standard Individual control MWR-WE10N Combined a/c indoor/erv controller The ERV can also be interfaced with touch central controller, DMS2 and BMS gateways, using MIM-N10 interface. MWR-VH12N Automatic Energy Saving Operations ERV automatically changes its operation mode depending on environment to save energy. (Manual selection also available) Exhaust Air Outdoor Air Damper Return Air Supply Air Exhaust Air Outdoor Air Damper Return Air Supply Air Smart CO2 Sensor (Option) ERV is automatically operated to give fresh air into room by sensing CO 2 level. When the CO 2 level increases, the fan will automatically increase speed. Only the amount of air required to keep the CO 2 level on an acceptable level will be ventilated. Heat recovery mode (summer/winter) Ventilation mode (spring/autumn) CO 2 level 950ppm Turbo High Low 700ppm CONTROLS Heat Exchange/Temperature Exchange Efficiency, Comply with regulations to promote high efficiency energy devices, Sound level was acquired in an anechoic room. Samsung Air Conditioning 91

DVM Chiller Specifications A Modular VRF Chiller Hybrid Model Name AG042KSVANH AG056KSVANH AG070KSVANH Power Supply, #, V, Hz 3,4,380-415,50 Mode - HEAT PUMP HP 15 20 25 USRT Ton 12 16 20 Performance Capacity (Nominal) Cooling 42 56 65 kw Heating 42 56 69.5 ESEER 5.70 5.40 5.00 EER 3.40 3.00 2.50 COP 3.60 3.20 2.85 Power Power Input (Nominal) Cooling 12.35 18.67 26 kw Heating 11.83 17.50 24.39 Max. Current 32 46 58 Fuse Rating 40 60 75 Air Flow Rate CMM 364 364 392 Fan External Static Max. mmaq 8 8 8 Pressure PA 78.45 78.45 78.45 Water Pipe inlet/outlet mm 40 40 50 Water Connections Type Flow Rate Cooling/Heating LPM 120/120 160/160 186/200 Flange Pressure Drop Nominal kpa 60 100 120 Refrigerant Sound External Dimension R410A (GWP=2088) (tco2e) 37.58 Factory Charging kg 18 Sound Pressure 60 62 63 db(a) Sound Power 80 83 85 Net Weight kg 446 446 465 Net Dimensions (WxHxD) mm 1795 x 1695 x 765 Operating Temp. Range Cooling 5~25 C Heating 25~55 Operating Water Flow range Water Flow Rate 60~240 80~320 93~400 Minin Water stored 29 392 490 These products contain Fluorinated greenhouse gas R410A (GWP=2088). CONTROLS Simply expand capacity on demand A modular design provides a wide choice of configurations. You can simply and flexibly combine modules and expand capacity from 12 to 320 ton in various ways to optimise energy or space savings or a balance of both. Easily increase performance & save space Its compatibility, large capacity and high space efficiency make it perfect for replacing chillers as it cuts down maintenance costs and frees-up valuable space, while expanding overall capacity. Easy to move and install modular design Its modular design and compact size reduces the it on site. With a small footprint it s easy to fit and combine multiple units even when there s limited space. 92 www.samsung.com/uk/dvms

AG042/56/70KSVANH Units: mm/inches CONTROLS Samsung Air Conditioning 93

Commercial Split Systems COMMERCIAL SPLIT SYSTEMS Commercial Air Conditioning The Commercial Air Conditioning range of split systems available from Samsung are ideal for retail, residential, hospitality and commercial applications, combining innovative stylish design with high efficiency and leading controls technology. Capacities range from 2.5 to 25kW and includes 1way cassettes at only 135mm thin, 4way cassettes with Motion Detection Sensors to reduce energy consumption, compact ducted units, a Virus Doctor filtration accessory for most model types and mini-multi-split (FJM) with 5 styles of indoor models. The commerical splits systems are also compatible with the DVM control systems, permitting integration with central controls and BMS gateways so providing a total site solution, whatever the commercial air conditioning unit installed. Residential Air Conditioning In addition, a range of RAC high wall systems and a stylish floor standing model are ideal for light commercial applications. Residential Heating products Complementing the commercial VRF water heating modules, the Samsung EHS air source heat pump range includes monobloc and split type models This 5th Generation product includes a Wi-Fi control option to remotely adjust temperatures and heat sanitary hot water from afar. Commercial High Wall Full HD Filter Up to 50m Pipe length (7.1kW model) Low noise level Indoor Model Name AC026FBRDEH AC035FBRDEH AC052FBRDEH AC071FBRDEH Nominal Capacity Cooling (range) kw 2.6 (1.2-3.5) 3.5 (1.2-3.7) 5.0 (1.9-6) 6.8 (2.2-8) Heating (range) kw 3.3 (1-4.2) 4.0 (1-4.4) 6.0 (1.5-6.2) 8.0 (1.9-9) UK Capacity Total Cooling kw 2.54 3.37 5.03 7.30 Sensible Cooling kw 1.91 2.53 3.77 5.84 Energy Label (c/h) A+ / A A+ / A A++ / A A++ / A Efficiency SEER (EER) 5.9 5.6 6.2 6.0 SCOP (COP) 3.9 3.9 3.8 3.8 Pdesign H (-10 o C) kw 2.4 2.5 3.3 5.0 Annual Electrical Consumption (c/h) KWh/a 154 / 862 219 / 898 282 /1216 414 / 1842 Dimensions WxHxD mm 820 x 285 x 205 820 x 285 x 205 1065 x 298 x 230 1065 x 298 x 230 Weight kg 8.2 8.2 11.5 11.5 Sound Pressure (H/M/L) db(a) 35/31/24 37/32/25 40/35/30 44/37/31 Power db(a) 53 55 60 63 Outdoor Model Name AC026FCADEH AC035FCADEH AC052FCADEH AC071FCADEH Dimensions WxHxD mm 790 x 548 x 285 880 x 798 x 310 Weight kg 33 38.5 55 Pressure db(a) 47 48 49 Sound Power db(a) 60 62 64 67 Power Supply 1ph Electrical Max Run Current A 10.3 10.8 20.3 Max Fuse Size A 13 25 Liquid/Gas inches 1/4 3/8 1/4 1/2 1/4 5/8 Pipe work Max Pipe length (Rise) m 20 (15) 30 (20) 50 (30) Refrigerant Factory Charge (tco2e) kg 0.95 (1.98) 1.4 (2.92) 1.8 (3.76) The products on this page contain Fluorinated greenhouse gas R410A (GWP=2088) Infrared control Std - MWR-WE10 hard wire option 94 www.samsung.com/uk/dvms

Commercial Split Systems Ceiling Suspended Slim Compact Design (235mm thin) Ceiling/Floor combination (5.0 and 7.1kW models) Virus Doctor filtration system option (on 10, 12, 14 & 16kW) Indoor Model Name AC052HBCDEH AC071HBCDEH AC100JNCDEH AC120JNCDEH AC140JNCDEH AC160JNCDEH Nominal Capacity Cooling (range) kw 5.0 (1.7-5.6) 7.1 (2.2-8) 10.0 (2.8-12) 12.0 (3.5-13.5) 14.0 (4.3-15.4) 14.0 (4.3-15.4) Heating (range) kw 6.0 (1.7-7.7) 8.0 (1.9-9) 11.2 (2.9-15.5) 13.0 (3.8-16.5) 16.0 (4.7-18.0) 16.0 (4.7-18.0) UK Capacity Total Cooling kw 4.96 6.80 9.87 12.14 13.98 14.97 Sensible Cooling kw 3.72 5.44 7.89 9.63 11.20 11.98 Energy Label (c/h) A+ / A A+ / A A+ / A A+ / A B / A C / B Efficiency SEER (EER) 5.9 5.3 5.8 5.7 (3.01) (2.84) SCOP (COP) 3.8 3.8 3.9 4.0 (3.61) (3.60) Pdesign H (-10 o C) kw 3.6 4.8 5.2 7.0 - - Annual Electrical Consumption (c/h) KWh/a 297/ 1126 487 / 1977 603 / 1867 737 / 2450 - - Dimensions WxHxD mm 1000 x 200 x 650 1000 x 200 x 650 1650 x 235 x 675 1650 x 235 x 675 1650 x 235 x 675 1650 x 235 x 675 Weight kg 20 22.5 42 42 42 42 Sound Pressure (H/M/L) db(a) 41/39/37 46/44/42 42/38/34 44/41/37 46/42/38 51/47/44 Power db(a) 60 64 60 62 64 68 COMMERCIAL SPLIT SYSTEMS Outdoor Model Name AC052FCADEH AC071FCADEH AC100JXADEH AC120JXADEH AC140JXADEH AC160JXADGH Dimensions WxHxD mm 790 x 548 x 285 880 x 798 x 310 940 x 998 x 330 940 x 1210 x 330 940 x 1420 x 330 Weight kg 38.5 55 70 77 90 96 Sound Pressure db(a) 48 49 52 54 53 56 Power db(a) 64 66 69 70 73 Power Supply 1ph 3ph Electrical Max Run Current A 10.8 20.3 26.7 26.7 26.7 14.7/ph Max Fuse Size A 13 25 30 15/ph Pipe work Liquid/Gas inches 1/4 1/2 1/4 5/8 3/8 5/8 Max Pipe length (Rise) m 30 (20) 50 (30) 75 (30) Refrigerant R410A Factory Charge (tco2e) kg 1.4 (2.92) 1.8 (3.76) 2.8 (5.85) 2.9 (6.06) 3.2 (6.68) 3.5 (7.31) ~ 10, 12 & 14kW 3phase power supply models also available Floor Console Slim and Smart Design (199mm thin) 2-way air outlet Virus Doctor filtration system as standard Indoor Model Name AC026FBJDEH AC035FBJDEH AC052HBJDEH Nominal Capacity Cooling (range) kw 2.6 (1-3.4) 3.5 (1.2-3.9) 5.0 (1.9-5.5) Heating (range) kw 3.5 (1-4.2) 4.0 (1-4.4) 5.6 (1.5-6.5) UK Capacity Total Cooling kw 2.70 3.52 5.06 Sensible Cooling kw 2.02 2.64 3.79 Energy Label (c/h) A / A+ A / A A / A Efficiency SEER (EER) 5.4 5.4 5.4 SCOP (COP) 4.0 3.9 3.8 Pdesign H (-10 o C) kw 2.3 2.3 3 Annual Electrical Consumption (c/h) KWh/a 169 / 805 277 / 826 324 / 1200 Dimensions WxHxD mm 720 x 620 x 199 720 x 620 x 199 720 x 620 x 199 Weight kg 15.2 15.2 15.2 Sound Pressure (H/M/L) db(a) 38/30.5/23 39/31.5/24 44/34.5/25 Power db(a) 53 55 60 Outdoor Model Name AC026FCADEH AC035FCADEH AC052FCADEH Dimensions WxHxD mm 790 x 548 x 285 Weight kg 33 38.5 Pressure db(a) 47 48 Sound Power db(a) 61 64 Power Supply A 1ph Electrical Max Run Current A 10.3 10.8 Max Fuse Size 13 Liquid/Gas inches 1/4 3/8 1/4 1/2 Pipe work Max Pipe length (Rise) m 20 (15) 30 (20) Refrigerant R410A Factory Charge (tco2e) kg 0.95 (1.98) 1.4 (2.92) The products on this page contain Fluorinated greenhouse gas R410A (GWP=2088) Samsung Air Conditioning 95

Commercial Split Systems 1Way Cassette Slim Compact Design Two stylish panel options COMMERCIAL SPLIT SYSTEMS Indoor Model Name AC026FB1DEH AC035FB1DEH Nominal Capacity Cooling kw 2.6 3.5 Heating kw 3.3 4.0 Energy Label (c/h) A+ / A A / A Efficiency SEER 5.6 5.4 SCOP 3.8 Pdesign H (-10 o C) kw 2.5 Annual Electrical Consumption (c/h) KWh/a 163 / 921 227 / 921 Dimensions WxHxD mm 970 x 135 x 410 Weight (including panel) kg 13 Sound Pressure (H/M/L) db(a) 30/27.5/25 33/30/27 Power db(a) 52 55 Panel Model db(a) PSSMA Dimensions WxHxD mm 1180 x 25 x 460 Outdoor Model Name AC026FCADEH AC035FCADEH Dimensions WxHxD mm 790 x 548 x 285 Weight kw 33 Sound Pressure db(a) 47 Power db(a) 60.0 62.0 Power Supply 1ph Electrical Max Run Current A 10.3 Max Fuse Size A 13 Pipe work Liquid/Gas inches 1/4 3/8 Max Pipe length (Rise) m 20 (15) Refrigerant R410A Factory Charge (tco2e) kg 0.95 (1.98) *Alternative panel: PC1NUPMA 4Way Mini Cassette Slim Compact Design (for 600x600 ceiling grid) Motion detect sensor option Virus Doctor filtration system option Indoor Model Name AC026FBNDEH AC035FBNDEH AC060FBNDEH AC071FBRDEH AC071FBNDEH Nominal Capacity UK Capacity Cooling (range) kw 2.6 (2.5-3.5) 3.5 (1-4.2) 5.0 (1.3-5.9) 5.8 (1.8-6.5) 6.8 (2-7.5) Heating (range) kw 3.3 (1-4.6) 4.0 (1-5) 5.5 (1.3-7.9) 7.0 (1.6-9) 7.5 (1.6-10) Total Cooling kw 2.65 3.37 4.85 5.77 6.67 Sensible Cooling kw 1.99 2.53 3.64 4.33 5.33 Energy Label (c/h) A++ / A+ A++ / A+ A++ / A A++ / A A++ / A Efficiency SEER (EER) 6.7 6.5 6.3 6.2 6.1 SCOP (COP) 4.0 4.0 3.8 3.8 3.8 Pdesign H (-10 o C) kw 2.4 2.4 3.1 4.8 4.8 Annual Electrical Consumption (c/h) KWh/a 139 / 840 189 / 840 278 / 1142 328 / 1769 390 / 1769 Dimensions WxHxD mm 575 x 250 x 575 575 x 250 x 575 575 x 250 x 575 575 x 250 x 575 575 x 250 x 575 Weight kg 13.7 13.7 14.4 14.7 14.7 Sound Pressure (H/M/L) db(a) 33/31/27 35/33/29 39/37/34 41/38/35 42/40/36 Power db(a) 48 50 53 56 58 Panel Model PC4SUSMF PC4SUSMF PC4SUSMF PC4SUSMF PC4SUSMF Dimensions WxHxD mm 670 x 45 x 670 670 x 45 x 670 670 x 45 x 670 670 x 45 x 670 670 x 45 x 670 Outdoor Model Name AC026FCADEH AC035FCADEH AC052FCADEH AC060FCADEH AC071FCADEH Dimensions WxHxD mm 790 x 548 x 285 880 x 798 x 310 Weight kw 33 38.5 55 Sound Pressure db(a) 47 48 49 Power db(a) 60 62 64 64 66 Power Supply 1ph Electrical Max Run Current A 10.3 10.8 20.3 Max Fuse Size A 13 25 Pipe work Liquid/Gas inches 1/4 3/8 1/4 1/2 1/4 5/8 Max Pipe length (Rise) m 20 (15) 30 (20) 50 (30) Refrigerant R410A Factory Charge (tco2e) kg 0.95 (1.98) 1.4 (2.92) 1.8 (3.76) *Alternative panel: PC4SUSMB 96 www.samsung.com/uk/dvms The products on this page contain Fluorinated greenhouse gas R410A (GWP=2088)

Commercial Split Systems 4Way Cassette Deluxe Slim Design only 204mm thin on 5 and 7.1kW models Virus Doctor filtration system option Optional Wi-Fi control option Indoor Model Name AC052FB4DEH AC071FB4DEH AC090FB4DEH AC100FB4DEH NS1254DXEA NS1404DXEA Nominal Capacity Cooling (range) kw 5.1 (1-6) 7.1 (2.2-8) 9.0 (3-10) 10.0 (4-12) 12.5 (3.5-14) 14.0 (3.5-15.5) Heating (range) kw 5.7 (1-7) 8.0 (1.9-9) 10.0 (2.2-13.9) 11.2 (3.5-15.5) 14.0 (3-16.2) 16.0 (3.5-18) UK Capacity Total Cooling kw 5.05 7.01 9.06 10.12 11.91 14.02 Sensible Cooling kw 3.78 5.26 7.25 8.10 9.95 11.22 Energy Label (c/h) A++ / A+ A+ / A A+ / A A+ / A A / A A / A Efficiency SEER (EER) 6.4 6.0 5.6 5.6 (3.21) (3.21) SCOP (COP) 4.0 3.9 3.8 3.8 (3.61) (3.61) Pdesign H (-10 o C) kw 3.0 4.5 6.6 7.6 - - Annual Electrical Consumption (c/h) KWh/a 279 / 1050 414 / 1615 563 / 2432 625 / 2800 - - Dimensions WxHxD mm 840 x 204 x 840 840 x 204 x 840 840 x 246 x 840 840 x 246 x 840 840 x 288 x 840 840 x 288 x 840 Weight kg 20.9 20.9 21.9 21.9 23.9 25.9 Sound Pressure (H/M/L) db(a) 35/32/29 37/35/30 40/36/32 44/39/34 44/40/36 45/41.5/38 Power db(a) 51 53 57 58 - - Panel Model PC4NUSKE PC4NUSKE PC4NUSKE PC4NUSKE PC4NUSKE PC4NUSKE Dimensions WxHxD mm 950 x 45 x 950 950 x 45 x 950 950 x 45 x 950 950 x 45 x 950 950 x 45 x 950 950 x 45 x 950 COMMERCIAL SPLIT SYSTEMS Outdoor Model Name AC052FCADEH AC071FCADEH AC090FCADEH AC100FCADEH RC125DHXEB RC140DHXEB Dimensions WxHxD mm 790 x 548 x 285 880 x 798 x 310 940 x 998 x 330 940 x 998 x 330 940 x 1210 x 330 940 x 1210 x 330 Weight kw 38.5 55 72 72 88 88 Sound Pressure db(a) 48 49 51 52 51 52 Power db(a) 64 67 68 69 - - Power Supply 1ph 1ph 1ph 1ph 1ph 1ph Electrical Max Run Current A 10.8 20.3 24.7 24.7 25 25 Max Fuse Size A 13 25 30 30 30 30 Pipe work Liquid/Gas inches 1/4 1/2 1/4 5/8 3/8 5/8 3/8 5/8 3/8 5/8 3/8 5/8 Max Pipe length (Rise) m 30 (20) 50 (30) 50 (30) 50 (30) 75 (30) 75 (30) Refrigerant R410A Factory Charge (tco2e) kg 1.4 (2.92) 1.8 (3.76) 3 (6.26) 3 (6.26) 2.9 (6.06) 3.4 (7.1) * Alternative panel: PC4NUSKA (PC4NBSKA-black version) ~ 10, 12.5 & 14kW 3phase power supply models also available 360 Circular Cassette Draft free perfect even cooling High efficiency range Virus Doctor filtration system option Indoor Model Name AC071KN4DKH AC090KN4DKH AC100KN4DKH AC120KN4DKH AC140KN4DKH Nominal Capacity Cooling kw 7.1 (2.2-8) 9.0 (3-11.3) 10.0 (3-12) 12.0 (3.5-13.5) 14.0 (3.5-15.5) Heating kw 8.0 (1.9-9) 10.0 (2.2-13.9) 11.2 (2.2-15.5) 13.0 (2.5-15.5) 15.5 (3.5-18) UK Capacity Total Cooling kw 7.23 9.28 10.29 11.90 13.37 Sensible Cooling kw 5.25 7.29 7.99 8.91 9.49 Energy Label (c/h) A++ / A+ A++ / A+ A++ / A+ A+ / A+ A / A Efficiency SEER (EER) 6.2 6.8 6.8 5.7 (3.21) SCOP (COP) 4.1 4.3 4.3 4.1 (3.60) Pdesign H (-10 o C) kw 4.5 5.3 5.3 7.0 - Annual Electrical Consumption (c/h) KWh/a 401 / 1537 463 / 1726 515 / 1727 737 / 2390 - Dimensions WxH(void)xD mm 947 x 281(233) x 947 947 x 365 (317) x 947 947 x 365 (317) x 947 947 x 365 (317) x 947 947 x 365 (317) x 947 Weight (including panel) kg 24.6 27.6 27.6 27.6 27.6 Sound Pressure (H/M/L) db(a) 36/33/29 43/38/33 44/39/33 45/40/35 45/41/37 Power db(a) 53 60 61 61 61 Panel* Model (square) PC4NUDMAN PC4NUDMAN PC4NUDMAN PC4NUDMAN PC4NUDMAN Dimensions WxHxD mm 1000 x 66 x 1000 1000 x 66 x 1000 1000 x 66 x 1000 1000 x 66 x 1000 1000 x 66 x 1000 Outdoor Model Name AC071KX4DKH AC090KX4DKH AC100KX4DKH AC120KX4DKH AC140KX4DKH Dimensions WxHxD mm 880 x 798 x 310 940 x 998 x 330 940 x 998 x 330 940 x 998 x 330 940 x 1210 x 330 Weight kw 50.5 72 72 80 92.5 Sound Pressure db(a) 49 52 52 54 53 Power db(a) 65 68 69 70 69 Power Supply ~ 1ph 1ph 1ph 1ph 1ph Electrical Max Run Current A 21.5 24.5 24.5 26.5 33.5 Max Fuse Size A 25 30 30 30 40 Pipe work Liquid/Gas inches 1/4 5/8 3/8 5/8 3/8 5/8 3/8 5/8 3/8 5/8 Max Pipe length (Rise) m 50 (30) 50 (30) 50 (30) 50 (30) 75 (30) Refrigerant R410A Factory Charge (tco2e) kg 1.5 (3.13) 3 (6.26) 3.5 (7.31) *Alternative panels: PC4NUNMAN (round) PC4NBDMAN (square-black) PC4NBNMAN (round black) ~ 10, 12 & 14kW 3phase power supply models also available The products on this page contain Fluorinated greenhouse gas R410A (GWP=2088) Samsung Air Conditioning 97

Commercial Split Systems DPM Multi CAC Split Systems COMMERCIAL SPLIT SYSTEMS 4Way Mini Indoor Units Type Indoor Panel Outdoor Branch Remote 7.1kW TWIN AC035FBNDEH x 2 PC4SUSMF x 2 AC071FCADEH MXJ-2D2509K MWR-WE10 10.0kW TWIN AC052FBNDEH x 2 PC4SUSMF x 2 AC100FCADEH MXJ-2D2509K MWR-WE10 12.5kW TWIN AC060FBNDEH x 2 PC4SUSMF x 2 RC125DHXEB MXJ-2D2509K MWR-WE10 14.0kW TWIN AC071FBNDEH x 2 PC4SUSMF x 2 RC140DHXEB MXJ-2D2509K MWR-WE10 10.0kW TRIPLE AC035FBNDEH x 3 PC4SUSMF x 3 AC100FCADEH MXJ-3D2509K MWR-WE10 12.5kW TRIPLE AC052FBNDEH x 3 PC4SUSMF x 3 RC125DHXEB MXJ-3D2509K MWR-WE10 14.0kW TRIPLE AC052FBNDEH x 3 PC4SUSMF x 3 RC140DHXEB MXJ-3D2509K MWR-WE10 14.0kW QUAD AC035FBNDEH x 4 PC4SUSMF x 4 RC140DHXEB MXJ-4D2509K MWR-WE10 4Way Standard Indoor Units Type Indoor Panel Outdoor Branch Remote 10.0kW TWIN AC052FB4DEH x 2 PC4NUSKE x 2 AC100FCADEH MXJ-2D2509K MWR-WE10 14.0kW TWIN AC071FB4DEH x 2 PC4NUSKE x 2 RC140DHXEB MXJ-2D2509K MWR-WE10 12.5kW TRIPLE AC052FB4DEH x 3 PC4NUSKE x 3 RC125DHXEB MXJ-3D2509K MWR-WE10 360 Cassette Indoor Units Type Indoor Panel Outdoor Branch Remote 20kW TWIN AC100KN4DKH x 2 PC4NUDMAN x 2 AC200KXAPNH MXJ-2D2509K MWR-WE10N 20kW TRIPLE AC071KN4DKH x 2 PC4NUDMAN x 2 AC200KXAPNH MXJ-3D2509K MWR-WE10N 25kW TWIN AC120KN4DKH x 2 PC4NUDMAN x 2 AC250KXAPNH MXJ-2D2509K MWR-WE10N 25kW QUAD AC071KN4DKH x 2 PC4NUDMAN x 2 AC250KXAPNH MXJ-4D2509K MWR-WE10N Large Ceiling Indoor Units Type Indoor Outdoor Branch Remote 20kW TWIN AC100JNCDEH x 2 AC200KXAPNH MXJ-2D2509K MWR-WE10N 25kW TWIN AC120JNCDEH x 2 AC250KXAPNH MXJ-2D2509K MWR-WE10N The products on this page contain Fluorinate greenhouse gas R410A (GWP=2088) 98 www.samsung.com/uk/dvms

Commercial Split Systems Slim Duct Slim Compact Design 200mm thin Virus Doctor filtration system option High lift drain pump option Duct HSP High Static Pressure and Long Pipe lengths Optional Wi-Fi control option Virus Doctor filtration system option Indoor Model Name AC026HBLDKH AC035HBLDKH AC052HBLDKH AC071HBLDKH AC180JNHPKH AC200KNHPKH AC250KNHPKH Nominal Capacity Cooling (range) kw 2.6 (1.2-3.5) 3.5 (1.2-3.5) 5.0 (1.1-6) 7.1 (2-8) 18.0 (6-20) 20.0 (7.5-23) 25.0 (9-28.5) Heating (range) kw 3.5 (1-4.2) 4.0 (1-4.4) 6.0 (1.1-7.2) 8.0 (1.5-9) 20 (4.8-22.5) 23.0 (8.5-25) 27.0 (10-32) UK Capacity Total Cooling kw 2.65 3.56 4.93 7.01 18.62 20.68 20.68 Sensible Cooling kw 2.12 2.86 3.95 5.61 14.90 16.55 16.55 Energy Label (c/h) A++ / A A++ / A A++ / A A+ / A+ A / A B / B D / C Efficiency SEER (EER) 6.3 6.1 6.1 5.9 (3.30) (3.10) (2.61) SCOP (COP) 3.8 3.8 3.8 4.0 (3.61) (3.45) (3.24) Pdesign H (-10 o C) kw 1.7 1.7 3.6 4.8 - - - Annual Electrical Consumption (c/h) KWh/a 144 / 626 201 / 626 287 / 1326 421 / 1680 - - - Dimensions WxHxD mm 700 x 199 x 600 700 x 199 x 600 1100 x 200 x 450 1100 x 200 x 450 1350 x 450 x 910 1350 x 450 x 910 1350 x 450 x 910 Weight kg 20 20 22.5 22.5 82.5 82.5 82.5 Sound Pressure (H/M/L) db(a) 40/37/34 40/37/34 33/30/27 37/34/31 43/39/35 44/40/36 47/42/37 Power db(a) 53 53 55 57 79 70 72 Air Flow Rate H/M/L CMM 8.0/6.5/4.9 9.2/7.4/5.8 15/12/9.0 20/15/10 71/60/50 72/62/48 80/64/51 Static Pressure (MAX) Pa 40 40 40 40 196 196 196 COMMERCIAL SPLIT SYSTEMS Outdoor Model Name AC026HCADKH AC035HCADKH AC052HCADKH AC071HCADKH AC180JXAPNH AC200KXAPNH AC250KXAPNH Dimensions WxHxD mm 720 x 548 x 265 720 x 548 x 265 880 x 638 x 310 880 x 638 x 310 940 x 1420 x 330 940 x 1630 x 460 940 x 1630 x 460 Weight kg 29.5 29.5 45 55 107.5 154 154 Sound Electrical Pipe work Refrigerant R410A Pressure db(a) 53 53 48 49 55 58 59 Power db(a) 63 63 63 64 76 75 77 Power Supply 1ph 1ph 1ph 1ph 3ph 3ph 3ph Max Run Current A 10 10 22 22 14.5 25 25 Max Fuse Size A 13 13 25 25 15 31.25 31.25 Liquid/Gas inches 1/4 3/8 1/4 3/8 1/4 1/2 1/4 5/8 3/8 3/4 3/8 3/4 3/8 7/8 Max Pipe length (Rise) m 20 (15) 20 (15) 30 (20) 50 (30) 75 (30) 75 (30) 75 (30) Factory Charge (tco2e) kg 0.9 (1.88) 1.3 (2.71) 1.5 (3.13) 4.6 (9.6) 6.6 (16.7) 6.6 (13.78) DPM Multi CAC Split Systems Ducted Indoor Units Type Indoor Outdoor Branch Remote 7.1kW TWIN AC035HBMDKH x 2 AC071HCADKH MXJ-2D2509K MWR-WE10 10.0kW TWIN AC052HBMDKH x 2 AC100HCADKH MXJ-2D2509K MWR-WE10 12.0kW TWIN AC060HBMDKH x 2 AC120HCADKH MXJ-2D2509K MWR-WE10 14.0kW TWIN AC071HBMDKH x 2 AC140HCADKH MXJ-2D2509K MWR-WE10 10.0kW TRIPLE AC035HBMDKH x 3 AC100HCADKH MXJ-3D2509K MWR-WE10 12.0kW TRIPLE AC035HBMDKH x 3 AC120HCADKH MXJ-3D2509K MWR-WE10 14.0kW TRIPLE AC052HBMDKH x 3 AC140HCADKH MXJ-3D2509K MWR-WE10 14.0kW QUAD AC035HBMDKH x 4 AC140HCADKH MXJ-4D2509K MWR-WE10 PLEASE NOTE: DPM Systems must only be installed in the same room and with ONE remote controller. ~3 Phase outdoor units (10, 12.5 and 14kW) are available at extra cost. The products on this page contain Fluorinated greenhouse gas R410A (GWP=2088). Samsung Air Conditioning 99

Commercial Split Systems Duct S MSP Deluxe Slim Compact Design 250mm thin up to 10kW Automatic air volume adjustment High lift drain pump optional Virus Doctor filtration system option COMMERCIAL SPLIT SYSTEMS Indoor Model Name AC035HBMDKH AC052HBMDKH AC060HBMDKH AC071HBMDKH AC090HBMDKH AC100HBMDKH AC120HBMDKH AC140HBMDKH Nominal Capacity UK Capacity Efficiency Annual Electrical Cooling (range) kw 3.5 (1.35-4) 5.0 (1.2-6) 6.0 (1.8-7.5) 7.1 (2-8) 9.0 (2.6-11.5) 10.0 (2.8-12) 12.0 (3-13.5) 14.0 (4.6-15.4) Heating (range) kw 4.0 (1.25-4.6) 6.0 (1.1-7.2) 7.0 (1.5-8.5) 8.0 (1.5-9) 10.0 (2.8-15.5) 11.2 (2.9-15.5) 13.0 (2.5-17) 16 (3.7-18) Total Cooling kw 3.55 4.93 5.90 7.01 8.98 9.87 12.04 14.00 Sensible Cooling kw 2.85 3.95 4.72 5.61 7.19 7.89 9.60 11.20 Energy Label (c/h) A / A A++ / A A++ / A+ A+ / A+ A+ / A+ A+ / A+ A / A+ B / A SEER (EER) 5.4 6.1 6.1 5.9 5.7 5.6 5.3 (3.02) SCOP (COP) 3.8 3.8 4.0 4.0 4.0 4.0 4.0 (3.61) Pdesign H (-10 o C) kw 2.0 3.6 4.8 4.8 6.8 6.8 7.0 - Consumption (c/h) Dimensions WxHxD mm KWh/a 227 / 737 287 / 1326 344 / 1680 421 / 1680 553 / 2380 625 / 2380 792/ 2450-850 x 250 x 700 850 x 250 x 700 850 x 250 x 700 850 x 250 x 700 1200 x 250 x 700 1200 x 250 x 700 1300 x 300 x 700 Weight kg 24.5 24.5 24.5 24.5 32 32 36 36 1300 x 300 x 700 Pressure Sound (H/M/L) db(a) 32/29/26 33/30/27 37/33/29 37/33/29 38/35/32 38/35/32 39/36/33 40/37/33 Power db(a) 52 53 57 57 61 61 65 66 Air Flow Rate H/M/L CMM 12/9.5/8.0 16/13.5/11 21/18/15 22/19/16 29/25/22 32/27/22 38/32/25 42/34/25 Static Pressure (MAX) Pa 147 147 147 147 147 147 147 147 Outdoor Model Name AC035HCADKH AC052HCADKH AC060HCADKH AC071HCADKH AC090HCADKH AC100HCADKH AC120HCADKH AC140HCADKH Dimensions WxHxD mm 790 x 548 x 285 880 x 798 x 310 880 x 798 x 310 880 x 798 x 310 940 x 998 x 330 940 x 998 x 330 940 x 998 x 330 Weight kg 33 45 55 55 72 70 77 88 Sound Electrical Pipe work Refrigerant R410A Pressure db(a) 47 48 49 49 52 52 54 53 Power db(a) 63 63 64 65 68 69 70 70 940 x 1210 x 330 Power Supply ~ 1ph 1ph 1ph 1ph 1ph 1ph 1ph 1ph Max Run Current A 18.7 22.7 22.7 22.7 26.7 26.7 26.7 26.7 Max Fuse Size A 20 25 25 25 30 30 30 30 Liquid/Gas inches 1/4 3/8 1/4 1/2 1/4 5/8 1/4 5/8 3/8 5/8 3/8 5/8 3/8 5/8 3/8 5/8 Max Pipe length (Rise) m 20 (15) 30 (20) 50 (30) 50 (30) 50 (30) 50 (30) 50 (30) 50 (30) Factory Charge (tco2e) kg 0.9 (1.88) 1.3 (2.71) 1.5 (3.13) 2.6 (5.43) 2.7 (5.64) 2.8 (5.85) ~ 10, 12 & 14kW 3phase power supply models also available The products on this page contain Fluorinated greenhouse gas R410A (GWP=2088). Controls and Accessories Remote Controllers Accessories MWR-WH00 MWR-WE10 MWR-WE10N MWR-SH00 MRK-A10N MR-EH00 MIM-H02 Wired Remote Controller (simple schedule control) Multi Function Wired Remote Controller (7-Day Schedule, unified control CAC/ERV/ERV+/AHU) Multi Function Wired Remote Controller (7 Day Schedule) HSP Duct and Ceiling CAC Simplified Wired Remote Controller Duct S Wireless Signal Receiver Kit with Receiver Wire Kit Wireless Remote Controller Wi-Fi Module for CAC IU (G4WC, mg4wc, Slim Duct and MSP Only) MCR-SMA MSD-CAN1 MSD-EAN1 MRW-TA MRW-TS MDP-G075SP MDP-G075SQ Motion detect sensor for 4Way Mini Cassette S-Plasma Ion Healthy Air Provider for 4Way Cassette S-Plasma Ion Healthy Air Provider for Duct S Ducted Unit Remote Temperature Sensor Remote Temperature Sensor (Duct S Ducted Unit) Drain Pump for Duct S Ducted Unit (External Assembly) Drain Pump for Duct S Ducted Unit (Internal Assembly) MWR-ZS10 MWR-ZS00 Zone Controller for Duct S Ducted Unit (Damper motors not included) Zone Controller and Damper Control Box for Duct S Ducted Unit (Damper motors not included) Interfaces MIM-B13E Centralised Control Interface Module MIM-B13D Centralised Control Interface Module MIM-B14 100 www.samsung.com/uk/dvms

Commercial Split Systems - FJM Free Joint Multi Outdoor units Flexible multi systems 2 to 5 indoor unit connection options Easy one touch commissioning Outdoor Model AJ040FCJ2EH AJ050FCJ2EH AJ052FCJ3EH AJ068FCJ3EH AJ070FCJ4EH AJ080FCJ4EH AJ100FCJ5EH Connections No 2 2 3 3 4 4 5 Max. Connection Capacity kw 6 8.5 10.5 12 17 Nominal Capacity Cooling kw 4.0 5.0 5.2 6.8 7.0 8.0 10.0 Heating kw 4.4 5.7 6.3 8.0 8.6 9.3 12.0 Efficiency SEER (EER) 6.11 6.07 5.77 5.66 5.31 5.22 5.24 SCOP (COP) 4.00 3.86 3.90 3.93 3.80 3.80 3.80 Dimensions WxHxD mm 790 x 545 x 285 790 x 545 x 285 880 x 638 x 310 880 x 798 x 310 880 x 798 x 310 880 x 798 x 310 940 x 998 x 330 Weight kg 37 40 49 57 65 65 74.5 Sound Pressure db(a) 45 46 46 48 48 49 54 Power db(a) 61 61 61 63 63 63 70 Power Supply ~ 1ph 1ph 1ph 1ph 1ph 1ph 1ph Electrical Max Run Current A 9.8 11.8 12.2 15.5 18.7 25 25 Max Fuse Size A 13 13 16 20 20 30 30 Liquid/Gas inches 1/4 1/2 1/4 1/2 1/4 1/2 1/4 1/2 1/4 1/2 1/4 5/8 1/4 5/8 Pipe work Max Pipe length (Rise) m 20 (15) 20 (15) 20 (15) 20 (15) 25 (15) 25 (15) 25 (15) Total Combined pipe m 30 30 50 50 70 70 80 Refrigerant R410A Factory Charge (tco2e) kg 1.3 (2.71) 1.6 (3.34) 2.2 (4.59) 2.2 (4.59) 2.8 (5.8) 2.8 (5.8) 3.3 (6.89) COMMERCIAL SPLIT SYSTEMS 1way Cassette Slim Compact Design Indoor Model MH026FSEA MH035FSEA Nominal Capacity Cooling kw 2.6 3.5 Heating kw 3.3 4.0 Dimensions WxHxD mm 970 x 135 x 410 970 x 135 x 410 Weight (including panel) kg 13 13 Sound Pressure (H/M/L) db(a) 30/28/25 32/30/27 Power db(a) 53 53 Panel Model PSSMA PSSMA Dimensions WxHxD mm 1180 x 25 x 460 1180 x 25 x 460 4way mini Cassette Slim Compact Design (for 600x600 ceiling grid) Indoor Model AJN016NDEHA AJN020NDEHA AJN026NDEHA AJN035NDEHA AJN052NDEHA Nominal Capacity Cooling kw 1.6 2.0 2.6 3.5 5.2 Heating kw 2.0 2.2 2.9 3.8 5.6 Dimensions WxHxD mm 575 x 250 x 575 575 x 250 x 575 575 x 250 x 575 575 x 250 x 575 575 x 250 x 575 Weight (including panel) kg 13.7 13.7 13.7 14.4 14.7 Sound Pressure (H/M/L) db(a) 33/29/24 33/29/24 34/30/25 36/33/29 40/36/32 Power db(a) 47 47 47 49 55 Panel Model PC4SUSMF PC4SUSMF PC4SUSMF PC4SUSMF PC4SUSMF Dimensions WxHxD mm 670 x 45 x 670 670 x 45 x 670 670 x 45 x 670 670 x 45 x 670 670 x 45 x 670 The products on this page contain Fluorinated greenhouse gas R410A (GWP=2088). Samsung Air Conditioning 101

Commercial Split Systems - FJM Floor Console Slim and Smart Design (199mm thin) Indoor Model MH026FJEA MH035FJEA MH052FJEA COMMERCIAL SPLIT SYSTEMS Nominal Capacity Cooling kw 2.6 3.5 5.3 Heating kw 2.9 3.8 5.6 Dimensions WxHxD mm 720 x 620 x 199 720 x 620 x 199 720 x 620 x 199 Weight (including panel) kg 15 15 15 Sound Pressure (H/M/L) db(a) 28/26/23 39/32/24 44/34/25 Power db(a) 53 59 60 Ducted Slim and Smart Design (199mm thin) Indoor Model NJ026LHXEA NJ035LHXEA MH052FUEA Nominal Capacity Cooling kw 2.6 3.5 5.2 Heating kw 2.9 3.8 6.0 Dimensions WxHxD mm 900 x 199 x 600 900 x 199 x 600 900 x 260 x 480 Weight kg 26 26 29 Sound Pressure (H/M/L) db(a) 30/28/25 32/30/27 37/35/33 Power db(a) 53 53 59 Air Flow Rate H/M/L CMM 8.6/7.6/6.6 9.8/8.8/7.8 16.3/15/13.5 Static Pressure Pa 40 40 80 High Wall - Boracay+ Stylish Wall Unit Indoor Model AR07KSFHBWKN AR09KSFHBWKN AR12KSFHBWKN AR18KSFHBWKN AR24KSFHBWKN Nominal Capacity Cooling kw 2.0 2.5 3.5 5.0 6.8 Heating kw 2.2 3.2 3.5 6.0 7.7 Dimensions WxHxD mm 820 x 285 x 227 820 x 285 x 227 820 x 285 x 227 1065 x 298 x 243 1065 x 298 x 243 Weight kg 8.2 8.2 8.2 11.5 11.5 Sound Pressure (H/M/L) db(a) 38/-/21 38/-/21 42/-/21 42/-/25 44/-/28 Power db(a) 56 56 59 58 63 High Wall - AR5580 Built-in Wi-Fi Indoor Model AR07KSWSAWKN AR09KSWSBWKN AR12KSWSBWKN AR18KSWSAWKN AR24KSWSAWKN Nominal Capacity Cooling kw 2.0 2.5 3.5 5.0 6.8 Heating kw 2.2 3.2 3.8 6.0 7.8 Dimensions WxHxD mm 826 x 261 x 261 826 x 261 x 261 826 x 261 x 261 1065 x 301 x 294 1065 x 301 x 294 Weight kg 9.5 9.5 9.5 13 13.5 Sound Pressure (H/M/L) db(a) 37/27/19 37/27/19 38/28/19 41/32/25 43/34/26 Power db(a) 54 54 56 58 62 High Wall - AR7580 Built-in Wi-Fi Built-in Virus Doctor Indoor Model AR07KSPDBWKN AR09KSPDBWKN AR12KSPDBWKN AR18KSPDBWKN AR24KSPDBWKN Nominal Capacity Cooling kw 2.0 2.5 3.5 5.0 6.8 Heating kw 2.2 3.2 4.0 6.0 8.0 Dimensions WxHxD mm 826 x 261 x 261 826 x 261 x 261 826 x 261 x 261 1065 x 301 x 294 1065 x 301 x 294 Weight kg 10 10 10 15.5 15.5 Sound Pressure (H/M/L) db(a) 38/29/16 38/29/16 40/30/16 42/30/25 43/34/26 Power db(a) 56 56 58 58 62 The products on this page contain Fluorinated greenhouse gas R410A (GWP=2088). 102 www.samsung.com/uk/dvms

And now the perfect guide has the perfect App New DVM-Pro is an advanced design automation tool that can be used in AutoCAD-based CAD mode or Windows-based Sales mode. This new programme helps you select system air conditioner equipment so you can easily and precisely design your air conditioning system. COMMERCIAL SPLIT SYSTEMS Sales Mode Indoor Unit and Outdoor Unit: Indoor unit and outdoor unit connection with accessory Piping: Basic or manual selection with system check and capacity simulation Wiring: Automatic diagram with communication wiring of indoor/outdoor/control units and electric power meters Control system: Automatic control unit selection Report: Specifications, diagrams with DWG and BMP format, quotation CAD Mode Quick, Easy, Precise Design AutoCAD add-on software (not included in new DVM-Pro) Automatic Calculation: Refrigerant and drain pipe size Automatic Selection: Refnet joint, header and distributor kit System Check: Installation regulation and refrigerant addition Easy Control System Selection Automatic Report: Piping installation diagram, equipment list and quotation Visit samsung.com/uk/dvms and download a copy from any DVM outdoor unit technical section. Samsung Air Conditioning 103