CONTENTS WIRING DIAGRAM

Similar documents
INSTALLATION INSTRUCTIONS

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

INSTALLATION INSTRUCTIONS

HUMIDITY SENSING BATH FAN

VENTILATION FAN / LED LIGHT

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

Installation Instructions Exhaust Fan With Light

breeze easytm model # F100-1W

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

Please Read and Save These Instructions Safety Information

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

READ AND SAVE THESE INSTRUCTIONS

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

VENTILATION FAN WITH LIGHT AND HEATER

Integrated Ventilation System

INSTALLATION MANUAL AND USER GUIDE

Installation Instructions Remote Blowers

Use, Care, and Installation Guide

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION MANUAL AND USER GUIDE

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

READ AND SAVE THESE INSTRUCTIONS

e Bath Fan with Light User s Guide

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

VENTILATION FAN WITH BLUETOOTH SPEAKER

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Bathroom Exhaust Fan

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Garage Ventilation Installation Instructions

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

e Bath Fan with Light User s Guide

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

User s Manual WS-68N30SS WS-68N36SS WS-68N42SS

Installation Instructions Preference Wall Mount Range Hood

e Bath Fan with Light User s Guide

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

e Heater/Exhaust Fan/Light User s Guide

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

RP, GP, XP Pro Series Installation Instructions

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Downdraft Raised Vent

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS

Bathroom Exhaust Fan/Fluorescent Light Combination

High Power Range Hood

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

Insulated Ventilators. Operating Instructions & Parts Manual

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

Bathroom Exhaust Fan/Fluorescent Light Combination

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Imperial. Read Before Starting Installation!

Installation. Professional Built-in Hoods

Solatube Daylight Dimmer Installation Instructions

WS-5530SS WS-5536SS WS-5542SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

SF180 Installation Instructions

User s Manual WS-5830SS WS-5836SS WS-5842SS

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

User s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the


Imperial. Cal. Products, Inc. Installation Instructions & Warranty Information. 425 Apollo Street Brea, CA

Operating and Installation Instructions

User s Manual HI30SS HI36SS HI42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Cooktop Chimney Ventilation Hoods

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Easy installation in both new construction and retrofit

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

IN014 Rev P Saber Way, Ward Hill, MA radonaway.com

UNDER CABINET RANGE HOOD

Pro Ventilation Hood Liners

RP / RPc Series Installation Instructions

Installation Instructions

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Transcription:

Panasonic Installation and Operating Instructions Ventilating Fan Model No. FV-051 OVSC1 FV-081 OVSS1 CONTENTS GENERAL SAFETY INFORMATION----------------- 2-4 DESCRIPTION ----------------------------------------- 4 UNPACKING ------------------------------------------ 4 SUPPLIED ACCESSORIES------------------------------ 4 DIMENSIONS- ---------------------------------------- 5 WIRING DIAGRAM----------------------------------- 5 FEATURE- --------------------------------------------- 6 PLEASE READ PRIOR BEFEOR INSTALLING------------ 7 INSTALLATION I (JOIST MOUNTING)---------------7-9 INSTALLATION II (WALL MOUNTING)----------------10 MAINTENANCE (CLEANING)- --------------------10-11 TROUBLE SHOOTING GUIDE-------------------------11 PRACTICAL GUIDE TO INSTALLATION --- BACK COVER SPECIFICATIONS------------------------- BACK COVER.... PRODUCT SERVICE---------------------- BACK COVER READ AND SAVE THESE INSTRUCTIONS Thank you for purchasing this Panasonic product. Please read these instructions carefully before attempting to install, operate or service the Panasonic product. Please carefully read the "GENERAL SAFETY INFORMATION" (P.2-4) of this manual before use. Failure to comply with instructions could result in personal injury or property damage. Please explain to users how to operate and maintain the product after installation, and this booklet should be presented to users. Please retain this booklet for future reference.

GENERAL SAFETY INFORMATION For Your Safety To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always observe the following safety precautions. Explanation of symbol word panels The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage caused when the denotation is disregarded and improper use is performed. I. AWA RN I N G I. injury or death. I A CA UT IQ N I Denotes a hazard that could result in minor injury. 2 Denotes a potential hazard that could result in serious I NOT/CE I Denotes a hazard that could result in property damage. The o following symbols are used to classify and describe the type of instructions to be observed. This symbol is used to alert users to a specific operating procedure that must be followed in order to operate the unit safely. {S) This symbol is used to alert users to a specific operating procedure that must not be performed. e This symbol is used to alert users not to disassemble the equipment. This symbol is used to alert users to make sure of grounding when using the equipment with the grounding terminal. IA WARNING I To reduce the risk of fire, electric shock or injury to persons, observe the following :.. Use this unit only in the manner intended by the manufacturer. If you have any.. questions, contact the manufacturer... Before servicing or cleaning unit, switch power off at service panel and lock the.. service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel... Installation work and electrical wiring must be done by qualified person(s) in.. accordance with all applicable codes and standards, including fire-rated construction... Sufficient air is needed for proper combustion and exhausting of gases through the.. flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities... When cutting or drilling into wall or ceiling, do not damage metal objects, electrical.. wiring and other hidden utilities. Q Ducted fans must always be vented to the outdoors.

GENERAL SAFETY INFORMATION IA WARNING I 0 These models are UL listed for tub and shower enclosures.... A statement to the effect that when the product is to no longer be used, it must.. not be left in place but remove, to prevent it from possibly falling.... Ceiling joist or wall stud must be subjected to static load more than five times the.. weight of the product.... Install the fan at least 1.5 m (5 feet) above the floor, and the fan must be installed.. above a counter or major appliances that serves as a barrier.... If this unit is to be installed over a tub or shower, it must be marked as appropriate.. for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit. e The product must be properly grounded. ~Do not install with a method which is not approved in the instructions. /::\ Do not use this fan with any solid-state speed control device. Solid state controls \.::I may cause harmonic distortion which can cause motor humming noise. /::\ Canada only: Not to be installed in a ceiling thermally insulated to a value greater \.::I than R40. @ Do not disassemble the unit for reconstruction. It may cause fire or electric shock. IACAUTION I... Follow all local electrical and safety codes, as well as the National Electrical.. Code (NEC) and the Occupation Safety and Health Act (OSHA). 0 Make sure that the electric service supply voltage is AC 120 V, 60 Hz. 0 0 Always disconnect the power source before working on or near the fan, motor or junction box. Protect the supply wiring from sharp edges, oil, grease, hot surfaces, chemicals or other objects.... The special-purpose or dedicated parts, such as mounting.. fixtures, must be used if such parts are provided. 0 Please wear gloves to protect hands during installation. /::\ Do not install this ventilating fan where interior room \.::I temperature may exceed 104 F (40 C). /::\ For general ventilating use only. Do not use to \.::I exhaust hazardous or explosive materials and vapors. ~ Do not kink the supply wiring. ~ Not for use in cooking area. (Fig.A) (Cooking area) Do not install above or '+--- inside this area./ ',, /I J \ "'- // ',~<5 ~.s"// ' / Cooking equipment Fig. A Floor 3

PLEASE READ PRIOR BEFORE INSTALLATION [For model : FV-081 OVSS1] Spot and continuous ventilation: This product is designed to run continuously ensuring a healthy environment at low airflow levels 24 hours a day. By utilizing the CustomVent Multispeed module the product is built to run continuously at a pre-set lower level (0, 30, 40, 50, 60, 70 CFM). The setting is dependent on the size of the house and the individual wishes of the homeowner. It is crucial that the installer pre-set the lower setting during the installation. Please refer to the chart below and the switch indication on page 6. CustomVent Multi-speed module (Lower setting). ASH RAE 62.2-2010 (sq.feet) Two Bedrooms Three Bedrooms Four Bedrooms Five Bedrooms <1,000 33 40 48 55 1,500 38 45 53 60 2,000 43 50 58 65 2,500 48 55 63 70 3,000 53 60 68 75 3,500 58 65 73 80 4,000 63 70 78 85 4,500 68 75 83 90 5,000 73 80 88 95 5,500 78 85 93 100 6,000 83 90 98 105 6,500 88 95 103 110 7,000 93 100 108 - This product is also built to take care of the homeowner's spot ventilation needs when the room is occupied and kicks up to a maximum level of 100 CFM when control switch is turned on. INSTALLATION I {JOIST MOUNTING) 1.Before installation, please remove the tape which protects damper during shipping and accessory screws from duct adaptor and the tape which fixes condensation sensor (FV-051 OVSC1 only), then check that the damper can open and close smoothly. (Fig.1) Note: Please remove the tape on damper according to the direction of arrow in Fig.1, otherwise the damper may be pulled out. 2.0pen one knock-out hole on junction box. (Fig.2) Note: There are two knock-out holes, please open one which is convient for wiring. Tape Accessory screws Condensation sensor (FV-051 OVSC1 only) Fig.1 Fig.2 ~~~~~~~~~~~~~~~~~7

PRACTICAL GUIDE TO INSTALLATION Properly insulate the area around the fan 3 inch or 4 inch roof jack, wall cap, to minimize building heat loss and gain. or soffit vent with backdraft damper (Fig.17) Mechanically connect duct to termination Loose fill or batt insulation can be placed and seal with mastic or approved foil faced tape directly over the fan housing in the attic. 2-3 ft straight run before~e~lb;ow~~~i;it!i Our fans and fan/light combination units In attic installation, do not create excessive heat that is a caulk box to drywall common problem with recessed light ~~~~~ fixtures or some competitor's fan/light S~ort piece of flexible duct helps Insulation alignment and absorbs sound. combination. Our efficient, cool-running Clamps plus mastic or approved Foil tape tightly covers all metal motors and our LED lighting unit do not foil faced tape at all flex joints duct joints (glue PVC joints) create enough ambient heat to be subjected to these limitations. The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated air flow. SPECIFICATIONS Model No. Duct Air Voltage Frequency Air volume Noise Speed Power Weight diameter at0.1"wg direction (V) (Hz) (inches) (CFM) (sanes) (rpm) (W) lb.(kg) 50 <0.3 733 4.5 FV-051OVSC1 Exhaust 120 60 4 80 0.4 856 8.5 100 0.9 954 12.4 30 <0.3 711 3.4 40 <0.3 723 3.8 7.0 50 <0.3 733 4.5 (3.2) FV-081OVSS1 Exhaust 120 60 4 60 <0.3 770 5.3 70 <0.3 805 6.5 80 0.4 856 8.5 100 0.9 954 12.4 HVI Certified performance based on HVI Procedures 915, 916, and 920. PRODUCT SERVICE Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit require service or parts, call Panasonic Call Center at 1-866-292-7299 (USA) or 1-800-669-5165 (Canada). Panasonic Corporation of North America Two Riverfront Plaza, Newark, NJ 07102 www.panasonic.com Panasonic Corporation 2017 Panasonic Canada Inc. 5770 Ambler Drive, Mississauga, Ontario L4W 2T3 www.panasonic.com Printed in China Issue date: 05/2017 P0517-0 510SC1420