Cooling Fans Contributing to Effective Use of Power

Similar documents
Development of the San Ace Airflow Tester - A Measuring Device for System Impedance and Operating Airflow of Equipment

"SAN ACE MC" for Pentium & Pentium 4

MPU Cooler for Pentium 4, SAN ACE MC Michinori Watanabe Toshiki Ogawara Haruhisa Maruyama Masayuki Iijima

High Performance Liquid Cooling System SAN ACE MC Liquid Tomoaki Ikeda Toshiki Ogawara Masashi Miyazawa Kouji Ueno

"SAN ACE MC" for Pentium *

EC Plug Fans EC FanGrid Retrofits for High Efficiency Air Handling Units

Development of Motor Fan Noise Prediction Method in Consideration of Operating Temperature during Engine Idling

Management of In-Bin Natural Air Grain Drying Systems to Minimize Energy Cost

Flexible and efficient: Close Climate Control for IT equipment

Impacts of Optimized Cold & Hot Deck Reset Schedules on Dual Duct VAV Systems - Theory and Model Simulation

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative

FAN WALL Technology. Product

Adding More Fan Power Can Be a Good Thing

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

AHRI Certification Program Scopes - COOLING

Optimized fan system design for the one-year cycle of a Heat Pump. Ziehl-Abegg SE Frieder Lörcher

Low Noise Type Hydraulically Driven Engine Cooling Fan System

ZERO Heating Power Vending Machine Hybrid ZERO

PERFORMANCE EVALUATION OF CO 2 HEAT PUMP HEATING SYSTEM ABSTRACT 1. INTRODUCTION

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

CHAPTER 4. HVAC DELIVERY SYSTEMS

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

Optiline Fan Array. The optimum number of fans for every application. The Optimum in Sound Energy Size Redundancy Reliability.

Efficient Motor Technology for the Home Appliance Industry

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Drink Showcase Equipped with Inverter Freezer

ASHRAE Headquarters Building: GSHP vs. VRF systems

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

LG VRF Systems. Air Conditioning Technologies

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Compaction versus the value of airspace: Solid Waste Compaction in Sanitary Landfills

Cultivation of Grafted Vegetables II. Development of Grafting Robots in Japan

Fans: Features and Analysis

Ducted Propeller. Airflow Volume

7. MECHANICAL SYSTEM DESIGN

Home Comfort Systems. g60v. The quietest furnace in its class*

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

A Novel Approach for the Thermal Management. of PC Power Supply

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Numerical Simulation of Fluid Flow and Heat Transfer in a Water Heater

Stock Vessels for Improved Quality and Energy Savings

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

[Patil* et al., 5(7): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

Cooling Fans ver ver.4

What is the correct type of fan: Axial, radial, diagonal?

Improving Air Handler Efficiency in Houses

Closed Circuit Cooling Towers

Small Room Heat Recovery Ventilation

Bill McCullough. Director ERV Products. Dallas, TX

Transcritical CO2 Bottle Cooler Development

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

Further Development of an Ion current Combustion Control System (ICCS)

THE CONTROL METHOD OF THE INFLOW TURBU- LENCE INTERACTION NOISE FOR ROUTER COOLING FAN

Cooling Solutions for High Heat Flux in Dense Packed Servers. Dr. Walter Angelis R&D Manager Aerodynamics Helmut Sebisch Key Account Manager

Development of Large Size Hybrid Fan

Water engineers and utilities are often

Mechanical Technical Report 1. ASHRAE Standard 62.1 Ventilation Compliance Evaluation

Ventilation. The idea behind our climate systems is efficiency and advanced simplicity.

UEE11 Electrotechnology. Training Package. UEENEEJ107A Air conditioning and refrigeration systems, major components and associated equipment SAMPLE

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

essential comfort Furnaces

TESTS OF ADSIL COATING

Va c S t a r V a c S t a r N e o. More Performance. Less Water. Less Energy.

Demand-Controlled Ventilation For Commercial Kitchens

Wire descaling and cleaning system ECOCLEAN.

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

Multi-Denco. » Precision Climate Control. Air Conditioning & Heating. Multi-DENCO

Capture Waste Heat with Ultra-High Efficiency

Technical description M 30-3C. Three compressions baler. The baler has continuing feeding and automatic working cycle

Xc21 air conditioner up to seer Xc21

Discover ebm-papst for buildings. Energy-efficient fans for a controlled room atmosphere.

Agenda and Objectives

HYBRID GAS HEAT PUMP WATER HEATER WITH THERMAL EFFICIENCY 120% 23rd World Gas Conference, Amsterdam Main Author. Atsuya Tajima Japan

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

Comparative analysis of power supply single speed air mover and an entire electronics enclosure system fan

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

High-powered and efficient thanks to excellent technology.

CASSETTE DUCT TYPE FLOOR CEILING. Light Commercial 18K BTU - 48K BTU

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

T-Series Climate Changer Air Handler. It s Hard To Stop A Trane.

GEOTHERMAL: THE SMARTER CHOICE

Fan Array Systems WHITE PAPER. Rad Ganesh, PhD, P.E. Director, R&D / Applications Twin City Fan Companies, Ltd. Minneapolis, MN, United States

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

Air flow management tutorial session. ACC Users Group 8 th Annual Conference Dallas, 4 October 2016 Sander Venema Howden Netherlands

GOLD RX/HC. The air handling unit with a reversible heat pump. Ventilation, heating and cooling all in one

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Development of Induction Heating Device for Corner of Bloom in Continuous Casting machine

EFFECT OF CENTRAL PILE IN INCREASING THE BEARING CAPACITY OF BORED PILE GROUPS

VENDED. Speed Queen Stack Tumble Dryers. 30 lb Tumble Dryer 45 lb Tumble Dryer

Multistage Centrifugal Blowers

International Journal of Engineering Research & Science (IJOER) ISSN: [ ] [Vol-2, Issue-11, November- 2016]

Solutions for. HVAC/Refrigeration. Axial Fans and Clutches

1.1. SCOPE OF THE WORK:

Who we are and what we do. The story of the world s leading manufacturer of axial impellers

Transcription:

Features: Technology Contributing to Effective Use of Power Cooling Fans Contributing to Effective Use of Power Hiromitsu Kuribayashi 1. Introduction In recent years, effective use of limited energy resources has become important topic in attempt to control global warming. In Japan, motors likely account for 6% to 7% of the total power consumption for industrial use (1). In addition, high efficiency of fans used for various applications and providing products equipped with high cooling performance with low power is a continuing issue. Regarding IT equipment and communication equipment, power is especially consumed a lot according to high performance and high efficient parts are required. Fans are no exception. Furthermore, for power generating devices including residential use fuel cells, high efficiency component parts, including fans, are demanded to keep the power consumed by the devices themselves to a minimum. Sanyo Denki develops fans along a strategy of providing top performance in the industry. Since 29, Sanyo Denki has led the industry with the development of the San Ace GA type, which was designed to have dramatically lower power consumption compared to conventional models, and we have supplied to market with a lineup of 12 products from 4 mm sq., 15 mm thick models to 92 mm sq., 38 mm thick models. Sanyo Denki also has a lineup of 12 counter rotating fans to cover high air flow and high static pressure areas, which are supplied to markets for IT equipment and communications equipment. This document first introduces low power consumption fans and counter rotating fans as cooling fans that contribute to effective use of power. Then, this document introduces variable speed fans that incorporate speed control function that make further effective use of power possible. 2. Effective Use of Power in Low Power Consumption Fans When developing a product, minimizing the energy required for the entire lifecycle of the product, from supplying parts to manufacture, distribution, use, and disposal, must be taken into consideration from the perspective of reducing global warming. Fig. 1 shows the calculation of the required energy (Note 1) for each processes from purchasing parts to disposal for one fan using the 8 mm sq., 38 mm thick GA type model (2) as an example, based on Sanyo Denki s environmentally compatible product design standards. The energy required for each processes, including purchasing, manufacture, distribution, and disposal, is 1Mcal or less, but the necessary energy when using the product is more than 1 Mcal, a significantly large value. This indicates that reducing the power consumed when using the product can minimize the energy required over the fan s entire lifecycle. In other words, developing products that achieve high cooling performance with low power is very important. With the development of the low power consumption fan GA type, the goal was to reduce the power consumption even further when the fans are mounted into customers devices. Normally, as motors become bigger, manufacturers gain freedom degree for the dimensions of each parts and it becomes easier to improve efficiency, but for fans, as the motors become bigger, manufacturers lose freedom degree in terms of the dimensions of the fans and optimal shapes are limited. Furthermore, as the external diameter of the motor become bigger, airflow pass area in the frame become smaller and the air flow through the airflow pass is bigger, which is disadvantage to low SPL (Sound Pressure Level). With these issues in mind, the optimal impeller and frame shape was discovered in order to achieve the air flow versus static pressure characteristics demanded by customers, and the motor and electric circuit conditions 3 SANYO DENKI Technical Report No.34 Nov. 212

to improve efficiency as much as possible when rotating the impeller was also discovered. By repeating numerical simulations using magnetic field analysis software and fluid analysis software, prototypes, and performance verification, we discovered the combination that achieves the highest performance. This document introduces the results of comparing the power consumption between the conventional G type / GV type and the low power consumption GA type in the, using the 8 mm sq., 38 mm thick size fans as an example. Fig. 2 shows the air flow versus static pressure characteristics and the air flow versus power consumption characteristics with each fan running at the same air flow. As described in Table 1, assuming that the GA type has power consumption of 1% the G type has power consumption of 125% to 15% and the GV type has 117% to 146%. From this, the low power consumption GA type model has lower power consumption compared to the conventional model in the and therefore it can be said to be a cooling fan that contributes to the effective use of power. We currently have lineup of 12 products, all of which have achieved low power consumption that is top of the industry: 4 mm sq., 15 mm thick; 4 mm sq., 2 mm thick; 4 mm sq., 28 mm thick; 52 mm sq., 15 mm thick; 6 mm sq., 15 mm thick; 6 mm sq., 2 mm thick; 6 mm sq., 38 mm thick; 8 mm sq., 32 mm thick; 8 mm sq., 2 mm thick; 8 mm sq., 38 mm thick; 92 mm sq., 25 mm thick; 92 Material production process Parts machining process Assembly process Distribution / sales mm sq., 38 mm thick. (Note 2) (3) Fig. 3 shows the appearance of the low power consumption series. Pa inch H2O 6 Static Pressure 2. 1.5 1..5 5 4 3 2 1. 1. 2. 3. 4. m 3 /min 2 of the new model (8 x 38 GA type) Operating range of (8x38 G type) * of (8x38 G type) * of (8x38 GV type) * of the new model (8 x 38 GA type) of (8x38 GV type) * W 2 4 6 8 1 12 14 CFM Air Flow * When fan is running at the same performance as the new model. Fig. 2: Comparison of consumption power in the (8 mm sq., 38 mm thick fan) Table 1: Comparison of power consumption in the (8 mm sq., 38 mm thick fan) Power W Ratio % Conventional model G type 19.1 to 19.5 125 to 15 Conventional model GV type 17.9 to 19. 117 to 146 Low power consumption GA type 15.3 to 13. 1 15 1 Power Consumption Operation Recovery Disassembly Fracture Sorting Material recycling Chemical recycling Thermal recycling Filling.1.1.1 1 1 1 1 1 Energy [Mcal] Fig. 1: Energy consumption for the product lifecycle (8 mm sq., 38 mm thick GA type model 9GA812P1H61) Fig. 3: Low power consumption fan series SANYO DENKI Technical Report No.34 Nov. 212 4

3. Effective Use of Power in Counter Rotating Fans If one fan has insufficient cooling performance, one method used to compensate for the insufficient performance is operating fans in tandem. However, for IT equipment such as 1U servers, the heat grows dramatically and there were cases where even two fans operated in series could not produce the necessary air flow. For this situation, Sanyo Denki developed counter rotating fans that combine two axial flow fans and use a method where the front and back driving blades rotate in opposite directions (4). As a first stage, in 23, the 4 mm sq., 56 mm thick CR type (5) was provided to the market. This later developed into a lineup of 12 counter rotating fans to meet market demands: 38 mm sq., 48 mm thick, 4 mm sq., 48 mm thick, 4 mm sq., 56 mm thick, 6 mm sq., 51 mm thick, 6 mm sq., 76 mm thick, 8 mm sq., 8 mm thick, 12 mm sq., 76 mm thick, and 172 x 15 x 12 mm thick models. These products have been continuously used in servers and communication equipment as essential parts. Fig. 4 shows a photograph of the counter rotating fan series. Fig. 5 shows the air f low versus static pressure characteristics and air flow versus power consumption characteristics when the 8 mm sq., 38 mm thick GV type is operated in tandem and when the 8 mm sq., 8 mm thick CRA type counter rotating fan is operated at the same air flow. As shown in Table 2, the power consumption in the is approximately 3% to 44% lower for the counter rotating fan compared to the tandem operations. If the fan was operated at the operation point A in Fig. 5, the power consumption for tandem operations would be 68.6 W. On the other hand, operating one counter rotating fan at the same air flow would be 47.6 W. If the fans were run continuously for one year in these states, the difference in power consumption would be 183 kwh. When calculated in terms of electricity costs, the conventional fans would cost approximately 3,66 yen. Pa inch H2O 14 Static Pressure 5. 4. 3. 2. 1. Fig. 4: Counter rotating fan series 12 1 8 6 4 2 Operating range of 8x38 G type in tandem of (8x8 CRA type) * of 8x38 GV type in tandem of (8x8 CRA type) * Assumed operating point A W 7 6 5 4 Power Consumption Difference in power consumption when run continuously for one year (68.6-47.6)(W) 24(h) 365(days) = 183 (kwh) Difference in electricity costs for one year 183(kWh) 2(yen/kWh) = 3,66 (yen) Assuming electricity costs of 2 JPY per 1 kwh From this, it can be said that counter rotating fans contribute to greater effective use of power compared to two fans operated in tandem.. 1. 2. Air Flow 3. 4. 2 4 6 8 1 12 14 * When fan is running at the same performance as the new model. m 3 /min CFM Fig. 5: Comparison of power consumption in the (8 mm sq., 38 mm thick in tandem, 8 mm sq. counter rotating fan) 5 SANYO DENKI Technical Report No.34 Nov. 212

Table 2: Comparison of power consumption in the (8 mm sq., 38 mm thick GV tandem, 8 mm sq., 8 mm thick counter rotating CRA fan) [W] (within the ) Ratio of power consumption [%] 8 mm sq., 38 mm thick GV type tandem 67.2 to 68.6 13 to 144 8 mm sq., 8 mm thick counter rotating CRA type (when running at the same air flow) 51.4 to 47.6 1 4. Effective Use of Power with Speed Control Technology As for BLDC fan generally, when the rotating speed decreases, the air flow decreases in proportion to the rotating speed and the power consumption decreases with the cube of voting speed. When there is surplus cooling performance, lowering the air flow by reducing the rotating speed can simultaneously reduce power consumption. Sanyo Denki developed and provided to market fans equipped with temperature sensors that can adjust the rotation speed depending on the temperature with thermally speed controlled fans or fans that can control the rotating speed through control lines from the equipment. Table 3 shows the types and characteristics of typical variable speed fans. In recent years, customers have wished for more detailed air flow controls depending on heat generation, so demand has grown for PWM control fans that can provide detailed speed controls. Sanyo Denki includes this feature as a standard specification in many new models. By using these variable speed fans to obtain only necessary air flow depended on the situation, the fans can contribute to effective use of power. Table 3: Typical variable speed fan types and characteristics Types Overview Characteristics Example fan models Dual speed fan Thermally speed controlled fan Voltage control fan PWM control fan Controls low speed or high speed with the L or H signal input to the C o ntro ls s p e e d d e p ending o n the detected temperature from temperature sensors in the interior or on the exterior of the fan Controls speed depending on the size of the voltage input into the Controls speed depending on duty from the PWM signal input into the U s e f u l t o c o n t r o l t w o speeds: low speed and high speed No need to use temperature sensors or control circuits on the equipment Controls speed with analog input (voltage) Can provide detailed control due to the digital input (PWM signal) 9G1212EG11 9G1212T4Gxx (Custom product) 9G1224V1G1 9GV1212P1J1 SANYO DENKI Technical Report No.34 Nov. 212 6

5. Conclusion This document introduced how fans developed by Sanyo Denki contribute to effective use of power, using the low power consumption fan and counter rotating fan as examples. Furthermore, it introduced variable speed fans that can contribute to further effective use of power by using speed control technology that can control the fan rotating speed as necessary. By using these fans and technologies developed by Sanyo Denki, customers equipment can not only save energy, but also contribute to suppressing global warming. We will continue to pursue high efficiency technologies for fans and develop products that deliver low power consumption and high performance. Hiromitsu Kuribayashi Joined Sanyo Denki in 1996. Cooling Systems Division, Design Dept. Worked on the development and design of cooling fans. Note 1: Conditions for example of required energy calculations during a product s lifecycle Fan model number: 9GA812P1H61 Operating conditions: Rated input, free air, continuous operations, room temperature Running conditions: Running 24 hours a day, 365 days a year Assumed total run time: 4, hours (4.56 years) Transportation method: Two ton truck Note 2: When each fans were released Documentation (1) The Institute of Applied Energy: 29 Report for the Promotion of Installing Energy Conservation Equipment Page 1 (21) (2) Masafumi Yokota and Others: Low Power Consumption Fan San Ace 8 GA Type SANYO DENKI Technical Report No. 3, pages 14-17 (21) (3) Katsumichi Ishihara: Cooling Fans that Contribute to Energy Conservation Products SANYO DENKI Technical Report No. 32, pages 3-4 (211) (4) Yoshihiko Aizawa: Cooling System Technology That Changes The Conventional Trend SANYO DENKI Technical Report No. 16, pages 3-6 (23) (5) Honami Oosawa and Others: San Ace 4 Counter Rotating Fan SANYO DENKI Technical Report No. 16, pages 15-18 (23) 7 SANYO DENKI Technical Report No.34 Nov. 212