Gas cylinder scale Model GCS-1

Similar documents
Indoor/outdoor resistance thermometer Model TR60

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Illumination unit For sight glass level indicator Model LGI

Inductive slot sensor

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

LOW PRESSURE Intrinsically Safe Transducer AST44LP

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. Dimensions

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

OPTIBAR DP 7060 Supplementary Instructions

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. Dimensions

Model 144H. Product Data Sheet , Rev DB February Content

Druck DPI 705/DPI 705 IS Series

Optoelectronic level switches, models OLS-C. Optoelektronische Füllstandsschalter, Typen OLS-C. Commutateurs de niveau opto-électroniques, type OLS-C

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

Temperature Measurement Transmitters for field mounting

Model 144H. Product Data Sheet , Rev DB February Content

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

Technical Data. Dimensions

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

PEPPERL+FUCHS GmbH

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

RE-PR3-E-27 3-Phase Panel Mount 27kW

Certification Supplement Manual

Operating Manual MS220DA

SUBMERSIBLE Flush Diaphragm Liquid Level Sensor AST4520

Magnetostrictive sensor For bypass level indicators Model BLM

Operating Instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

INSTRUCTION & SERVICE MANUAL

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

Dräger Polytron 5700 IR Detection of flammable gases and vapours

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

Certification Supplement Manual

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Dräger Polytron 8000 Stationary gas detector (EC)

/8 DIN Level Indicator

OPTIBAR P 1010/2010 C Supplementary instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

AO Annunciator Module

GETTING STARTED GUIDE NI AI/8 AO/4 DIO, 0 V to 5 V, 12 Bit, 20 ks/s Aggregate

ProcessMaster, HygienicMaster FEX300, FEX500

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

Dräger Polytron 8310 IR Detection of flammable gases and vapour

PROFIBUS-PA Display RID 261 PROFIBUS-PA

FAST RESPONSE TEMPERATURE SENSORS 42.11a

SIMRAD GD10PE IR GAS DETECTOR

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

FC22 Compression Load Cell

TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Technical Data. Dimensions

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

VERSAFLOW VORTEX Supplementary instructions

INSTRUCTION MANUAL (ATEX / IECEx)

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

D5100 Industrial Differential Pressure Transducer

Hygro/hygrothermal transducers (hygrometric)

Beck. The differential pressure transmitter for air

I/A Series 716C 1/16 DIN Temperature Controller

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

ExPolar Heating System

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Operating Manual MS220KA and MSR220KA

Software Version 2.01 LEVEL MONITOR MODEL 220

The A-series Eletta Flow Monitor with local indication and analog output

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

D5100 Industrial Differential Pressure Transducer

Snifter ATEX22 VERSION. User Manual. Distributor

RS Pro Infrared Temperature Sensor

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

Ultrasonic Level Measurement nivopuls FDU 10 S

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Laser Distance Sensor Type M Analog-Output

Operating Instructions Edition 02/2007

4) Intrinsic Safety Certification

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

GETTING STARTED GUIDE NI AI, ±29.4 mv/v, 24 Bit, 10 ks/s/ch Simultaneous, 350 Ω Quarter-Bridge Completion

Differential pressure sensors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Transcription:

Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in chemical delivery systems Industrial weight measurement Special features High overload safety up to 400 % 0.1 % FS accuracy Meets the highest EMC requirements Measuring ranges 0... 60 lbs to 0... 300 lbs (0... 27.22 kg to 0... 136.08 kg) High ingress protection, IP65, for outdoor use and processes with high condensation Gas cylinder scale model GCS-1 Description The model GCS-1 gas cylinder scale has been designed for indoor and outdoor use in gas cabinets or gas containers. Due to its high IP65 ingress protection, there is no concern with using the gas cylinder scale for gas cylinders with heavy condensation. The robust and compact design features high accuracy and temperature stability, meeting the requirements of the semiconductor industry. The gas cylinder scale meets the highest overload and EMC requirements in order to ensure safe, error-free and accurate operation. Page 1 of 5 Data sheets showing similar products and accessories: Digital indicator; model DI30; see data sheet AC 80.05

Measuring ranges Measuring ranges lbs Measuring range 0... 60 0... 100 0... 300 Overload safety 0... 250 0... 300 0... 750 kg Measuring range 0... 27.22 0... 45.36 0... 136.08 Overload safety 0... 115 0... 130 0... 340 Reference conditions (per IEC 61298-1) Temperature: 15... 25 C Atmospheric pressure: 860... 1,060 mbar Humidity: 45... 75 % r. h. Nominal position: Horizontal Power supply: DC 24 V : see Output signal Other measuring ranges on request. Output signal Model GCS-1-A (2-wire) GCS-1-G (4-wire) GCS-1-F (4-wire) Output signal 4... 20 ma DC 0... 5 V DC 0... 10 V Model GCS-1-A: (power supply - 10 V) / 0.02 A Model GCS-1-G: > 5 kω Model GCS-1-F: > 10 kω Voltage supply Power supply DC 14... 30 V Maximum output current 35 ma Accuracy specifications Accuracy of analogue signal 0.1 % of span Including non-linearity, hysteresis, zero offset and end value deviation (corresponds to measured error per IEC 61298-2) Operating conditions Free fall Resistant to impact of 90 kg from a height of 10 cm Ingress protection IP65 (IEC 60529) Ex marking Ex markings Option 1 without Ex approval Option 2 (ATEX) II 3G Ex na IIC T4/T5 Gc X (IECEx) BVS 16.0001X Ex na IIC T4/T5 Gc Permissible temperature ranges Ambient: -20... +50 C (T4) -20... +40 C (T5) Storage: -20... +60 C Operation: -10... +50 C Materials Sensor Aluminium Case Stainless steel Base plate Stainless steel Non-linearity (IEC 61298-2) 0.05 % of span (BFSL) Long-term stability (per month) 0.04 % of span (at reference condition) Adjustability of zero point, span ±5 % through built-in potentiometer Temperature coefficients in rated temperature range Mean TC zero point: ±0.1 % of span / 10 K Mean TC span: ±0.1 % of span / 10 K Page 2 of 5

Safety-related maximum values (only valid for instruments to ATEX category 3G) Model GCS-1-A (4... 20 ma) Model GCS-1-G (DC 0... 5 V) Model GCS-1-F (DC 0... 10 V) Power supply DC 14... 24 V DC 14... 24 V DC 14... 24 V Power limitation P i 1 W 1 W 1 W Electrical connection Type of connection: Cable outlet Cable length: 6 m ( 20 ft) Electrical safety Short-circuit resistance: S + vs. U- Reverse polarity protection: U+ vs. U- Insulation voltage: DC 500 V Connection diagram 2-wire 4-wire Non-hazardous area Hazardous area Non-hazardous area Hazardous area Voltage source Voltage source Brown Red Orange (e.g. digital indicator) Black (e.g. digital indicator) Brown Black Shield (connected to case) Shield(connected to case) Seperate conductor (to be provided by end-user) Seperate conductor (to be provided by end-user) Pin assignment (2-wire) U+ / S+ brown (BN) U- / S- black (BK) Pin assignment (4-wire) U+ red (RD) S+ orange (OG) U- black (BK) S- brown (BN) Page 3 of 5

Dimensions in mm Weight approx. 13 lbs approx. 6 kg Approvals Logo Description Country EU declaration of conformity EMC directive EN 61326 emission (group 1, class B) and interference immunity (industrial application) ATEX directive (option) Hazardous areas European Union - Ex n Zone 2 Gas [II 3G Ex na IIC T4/T5 Gc X] IECEx (Option) Hazardous areas - Ex n Zone 2 Gas [Ex na IIC T4/T5 Gc] International Approvals and certificates, see website Page 4 of 5

s Without Ex approval Measuring range GCS-1-A (4... 20 ma) GCS-1-G (DC 0... 5 V) GCS-1-F (DC 0... 10 V) 0... 60 lbs / 0... 27.22 kg 14196214 14196221 14196228 0... 100 lbs / 0... 45.36 kg 14196215 14196223 14196229 0... 300 lbs / 0... 136.08 kg 14196216 14196224 14196230 IECEx Ex na IIC T4/T5 Gc ATEX II 3G Ex na IIC T4/T5 Gc X Measuring range GCS-1-A (4... 20 ma) GCS-1-G (DC 0... 5 V) GCS-1-F (DC 0... 10 V) 0... 60 lbs / 0... 27.22 kg 14196208 14196217 14196225 0... 100 lbs / 0... 45.36 kg 14196210 14196218 14196226 0... 300 lbs / 0... 136.08 kg 14196213 14196220 14196227 Accessories Digital indicators Designation AC 230 V AC 110 V Digital indicator DI30 in wall-mount enclosure 12458741 12489841 Digital indicator DI30 panel mounting 7539422 12489825 For operation in accordance with the ATEX directive an isolated barrier is required. 11/2006 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 5 of 5 05/2017 EN WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de