Swing Door Operator DORMA CD 400

Similar documents
Hold-open magnets DORMA

Universal operator - easy to install, reliable in operation

Technical Documentation PORTEO. reddot design award winner geprüfte Sicherheit. achieved for: Ease of Use.

Free swing slide-channel door closer TS 99 DORMA. in Contur Design

The Plus for the door. PORTEO. Opening and closing made easy.

Cam action door closer system DORMA TS 93

TS 93. Cam action door closer system in Contur Design

Panic Hardware PHA 2500 DORMA PHA 2500, GB

BJ WALLER ARCHITECTURAL IRONMONGERS DOOR CLOSERS

Layout S. 6 DORMA CI-2012 Englisch Stand

Panic Hardware PHA 2500 DORMA PHA 2500, GB

TS 93. Cam action door closer system in Contur Design

PHA Panic Hardware for timber doors

EM Hold-open magnets

Easy-action Door Closer DORMA TS83

Hold-open device Hold-open system DORMA TS73EMR TS73EMF

01_TT_TST_04_61_GB.qxd :30 Uhr Seite 4. Door Closers and Door Control Systems

Concealed cam-action door closer system DORMA ITS 96

ED 100 ED 250. Modular swing door operators.

Concealed cam-action door closer system DORMA ITS 96

PHA 2000 PHB 3000 EXIT PAD

ED 100 ED 250. Swing door drives

ED 100 ED 250. Swing door drives

ES 200. Sliding door operator

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

Updated to. include Declaration of Performance Certificates WHICH DOOR CONTROL? Meeting the requirements of the Equality Act & Fire regulations

FDC/ -B. Product information SYSTEM TECHNOLOGY FOR THE DOOR ECO

DC300 Rack and pinion door closer with link arm

DC200 Rack and pinion door closer with link arm

DORMA. Free Swing and Hold-open Solutions for Fire Doors. An alternative to Fire door keep shut

Security Door Closer Safe and secure by design. ASSA ABLOY Door Controls

ECO ETS Electromotive drive

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

1 Door closers. Door closers Technical information. The global leader in door opening solutions.

DC300 Rack and pinion door closer with link arm

SIMPLY THE WIDEST FOLDING DOOR. FFT FLEX Green. Maximum clear opening widths and best thermal separation.

All by design. ASSA ABLOY Door Controls

DC340 Rack and pinion door closer with guide rail or link arm

NEW. TS 98 XEA: Licence to close. Slide channel door closer TS 98 XEA

GEZE SAFETY TECHNOLOGY. GEZE SecuLogic EMERGENCY EXIT SYSTEMS SAFETY ON ESCAPE AND RESCUE ROUTES BEWEGUNG MIT SYSTEM

TS 99 EN 2-5. Free-swing slide channel door closer in Contur design

5900 SERIES Low Energy Power Operator

ABLOY DOOR CLOSERS Exactly the right choice

ABLOY FIRE DOOR CLOSING SYSTEMS

BST/FBST COMFORT LINE. Curved Sliding Doors

Swedish Technical Approval SC

ES 200 T Easy ES 200 T ES 200 T-2D

GEZE SAFETY TECHNOLOGY. GEZE SecuLogic EMERGENCY EXIT SYSTEMS SAFETY ON ESCAPE AND RESCUE ROUTES BEWEGUNG MIT SYSTEM

ELECTRIC LOCKS. Europrofile range

UK Product Guide. Fire Doors.

DELTA reflex motion detector IP55

Meeting the requirements of the Equality Act & Fire regulations. Which Door Control?

2409/2900. Fire Guard

5900 Series X-in Low Energy Power Operator

ABLOY DOOR CLOSERS Excatly the right choice

2408/2900. Fire Guard

Sensing light curtain as per DIN 18650/EN 16005

ES 200. Sliding door operator

Risk assessment and analysis for swing gates

ABLOY DC335 DOOR CLOSER New Rack and Pinion Door Closer ABLOY DC335 is a modern high quality door closer for all kind of door applications.

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Door Closers For Every Application. Door Closers for Every Application 02

Swing Fire Door BS99. Swing Fire Door BS99. Swing Fire Door BS99 Sound Proofing A40

Automatic swing door solutions. We make access in life smart and secure.

A Beginners Guide to Inner Range Systems

Panic Exit Devices. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

CARD ACCESS CONTROL SYSTEM

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

Market Introduction DORMA. Modular Panic Hardware System PHA 2000 / PHB 3000

Proximity Detection & Collision Avoidance. Strata s solutions for surface, underground, and surface-to-underground

ES 200 Easy. Sliding door operator

TS 99 FL/FLR EN 2-5. Free-swing slide channel door closer in Contur design

Dräger Polytron 5720 IR Toxic Gas Detection

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

Installation and Operating Instructions

Fire Door Closing Systems

Save energy. ARGUS presence detectors

ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE

For architects, builders and planners. The new way to convey energy and signals. Hahn Türband 4 Inductio.

Panic & emergency exit devices. CFPA-E Guideline No 2:2013 F

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

Products. PX-1 Smoke Alarm Device PX-1C Radio-Linked Smoke Alarm Device PX- ip Gateway Pyrexx App.

Panel Mounted Fault Annunciator Series

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

record DFA 127 The silent, energy-saving automatic swing door operator

561-MB256 plus. Intruder alarm control panel. Performance features

FCP 320/FCH 320 Conventional Automatic Fire Detectors

Sensing light curtain as per DIN 18650/EN 16005

Instructions for the fan motor control system with integrated wiring terminals SILVER C

COMPACT FLAME CONTROLLER CFC 2000

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

Circlelock. The high security interlocking door. Security Access. Security Access

5000 INSTALLATION GUIDE

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

The EN54 Part 2 and 4 Fire System

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

ABLOY EFEND. New name for security

Transcription:

Swing Door Operator DORMA CD 400

Swing Door Operator DORMA CD 400 Universal applicability, simple installation, reliable function The reliability of high-convenience access solutions is gaining in importance against the background of growing security awareness. In order to meet the demands associated with this security imperative and, at the same time, ensure high traffic load capacities, DORMA has developed its CD 400 system, an advanced electro-mechanical swing door operator with slide channel. As a fleible system that can be integrated within a wide range of applications, the DORMA CD 400 is ideal for the automation of swing doors up to a width of 0 mm and leaf weights up to 10 kilograms. Aesthetically elegant and with a high degree of user friendliness, the system is characterised by its etensively noiseless operation. Indeed, thanks to the electro-mechanical drive principle, the acoustically CD 400 is virtually imperceptible. The fleibility of the CD 400 is underlined by the wide variety of operating modes it offers. Aside from the functions Off, Automatic, Eit Only and Permanent Open, the control unit is also equipped for capabilities such as Night-Bank, Push & Go and Low Energy for disabled access, plus a pushbutton-activated emergency off/stop function. This means that this efficient operator for swing doors can be programmed to fit perfectly into a wide range of different situations. The CD 400 also impresses through its ease of installation. With the mounting backplate, fiing costs, effort and time for fitting the CD 400 are minimised. The unit is also adaptable to any fiing position (pull side, push side, LH/RH). This variability means that the myriad safety requirements governing modern access solutions can be readily satisfied to optimum effect. The CD 400 is ideal both for emergency eits and fire doors. The powerful automatic drive unit combined with the radar motion detectors inconspicuously integrated in the SSCD sensor slide channel for door activation, and also the two sensors for monitoring the through-passage zone, provide further safety benefits. And, of course, the CD 400 can also be combined with the Softline slide channel. A significant aspect in functional terms today is the Features and benefits Simple and time-efficient installation with specially designed mounting backplate One operator can be used for all applications whether LH, RH, pull side or push side Customising adjustment of the operating curve can be performed simply and fleibly using the Automatic Service Program (ASP) Settings and servicing can be implemented with ease reliable protection of buildings and/or sections of same against unauthorised access. With the etensive range of program variants, the CD 400 system in conjunction with the appropriate components is able to ensure effective restriction. DIN 1 23/T4 via the infra-red interface without the need for etensive dismantling Numerous special functions already integrated in the standard system (no epansion modules needed) Top jamb and door leaf installation both possible Optional integration of motion detectors and safety sensors in the sophisticated slide channel assembly 2

Applications Standard doors, 1 and 2 leaves Fire and smoke check doors, 1 and 2 leaves Door leaf width in standard doors per leaf Door leaf width for fire and smoke-check doors per leaf 1750 to 0 mm 1750 to 1250 mm Door leaf weight, ma. 10 kg Frame reveal depth for standard doors 40 mm to 200 mm for fire and smoke check doors installation on the pull side 40 mm to 200 mm installation on the push side 40 mm to 100 mm Caution! Use special operator model only for push side (opposite hinge side) mounting on fire and smoke check doors must be specifically indicated in order. Technical data of the drive unit Closing force EN 5 Dimensions Height Depth Width 1120700mm Etended/continuous cover for 1 and 2-leaf operators Weight per operator Opening time, infinitely variable Closing time, infinitely variable Hold-open time, infinitely variable Backcheck, infinitely variable Delayed action, infinitely variable Latching/delatching action, infinitely variable Wall blanking, infinitely variable Operating speed, infinitely variable Acceleration angle of door Deceleration angle of door Opening angle Static force Holding current Delayed opening for locking mechanism 17 kg Opening angle, ma. 110 Adjustable via learning cycle and ASP Suitable for pull and push side and LH/RH doors Power consumption, ma. Power supply data Power supply for eternal accessories 250 W 2 V, 50/0 Hz 24 V DC; 1,5 A Class of protection IP 20 TÜV type-approved Compliant with EU low-voltage directives Quality-assured manufacture to ISO 00 Adjustable operating curve parameters 3 s 3 s 0 s to 10 s Operational modes Off Automatic Permanent open Eit only Partial opening (for double doors, and nurse/bed control) Special functions Airlock control Timed airlock function Night-bank control Push & Go mode Low-energy mode Operation to pren 1250 Current impulse relay function Door closer function in de-energised condition Prepared for connection of the following accessories SSCD sensor slide channel with integrated radar detector and infra-red sensors Softline slide channel Infra-red sensors: DORMA IRS-2-33/70//120 (pull and push sides) Electro-mechanical door locking mechanism Electric strike (fail-safe/fail-secure principle) Emergency eit motor lock with automatic locking action: DORMA SVP Access control system Module for interfacing with building management system (EIB compatible) 2 different activators Smoke detector with integral power pack Smoke detectors: DORMA RM, RM-ED (power supply for smoke detectors 24 V DC, stabilised) Radio remote control Double door co-ordinator Eternal program selectors (internal integrated program switch as standard) standard optional 3

DORMA CD 400 For single-leaf doors Installation on the pull side with SSCD sensor slide channel LH and RH doors (eample shows LH/ISO door) 700 94 255,25 255,25 2 V 19 (h2) 109 (h1) 39 51 4 77 113 54 270 W 20, 4 49 b c 7,5 a Z Installation on the push side with SSCD sensor slide channel LH and RH doors (Eample shows RH/ISO 5 door) 700 94 255,25 255,25 0 (h1) 2 V 10 35 22 4 15 4 55 37, (h2) 72 270 W 10,4 49 b c 7,5 a Z 4

Operator arm lengths with SSCD 5 20 51 19 0,5 9 49 *If mounted on the pull side (hinge side) of fire and smoke check doors, the CD 400 may only be used for frame/lintel depths from 0 to 200 mm. Installation type: Hinge side, pulling * Z W a b c 40 < 200 100 370 740 110 05 0 < 20 10 40 740 210 05 0 200 1100 00 740 420 05 Operator arm lengths with SSCD 5 20 37,5 22 0,5 9 49 **If mounted on the push side (opposite hinge side) of fire and smoke check doors, the CD 400 may only be used for frame/lintel depths from 0 to 100 mm. For frame/lintel depths of 0 to 50 mm, the main arm length required is 40 mm, and for depths from 50 to 100 mm, the main arm length required is 00 mm. Make sure that the door width and slide channel length are sufficient for the application! Installation type: Opposite hinge side, pushing ** Z W a b c 40 < 100 1950 40 40 120 705 100 200 1050 00 940 1 05 = Frame reveal depth Z = Minimum door width W = Minimum operator arm length a =Minimum length SSCD b, c = Recommended hole dimensions 5

DORMA CD 400 For single-leaf doors Installation on the pull side with Softline slide channel LH and RH doors (Eample shows LH/ISO door) 700 94 255,25 255,25 2 V 19 (h2) 109 (h1) 39 51 4 270 77 113 W 20, 4 29 b c a Z Installation on the push side with Softline slide channel LH and RH doors (Eample shows RH/ISO 5 door) 700 94 255,25 255,25 37,5 (h2) 0 (h1) 2 V 10 22 35 4 270 4 W 10,4 15 55 47,5 b c a Z

Operator arm lengths with Softline slide channel 5 20 51 19 0,5 54 20 *If mounted on the pull side (hinge side) of fire and smoke check doors, the CD 400 may only be used for frame/lintel depths from 0 to 200 mm. Installation type: Hinge side, pulling * Z W a b c 40 < 100 1750 370 52 0 35 40 < 10 150 40 52 170 35 0 200 1000 00 52 355 35 Operator arm lengths with Softline slide channel 5 20 37,5 22 0,5 54 20 **If mounted on the push side (opposite hinge side) of fire and smoke check doors, the CD 400 may only be used for frame/lintel depths from 0 to 100 mm. For frame/lintel depths of 0 to 50 mm, the main arm length required is 40 mm, and for depths from 50 to 100 mm, the main arm length required is 00 mm. Make sure that the door width and slide channel length are sufficient for the application! Installation type: Opposite hinge side, pushing ** Z W a b c 40 < 120 750 370 52 70 35 20 < 100 50 40 723 70 100 < 200 950 00 37 100 20 = Frame reveal depth Z = Minimum door width W = Minimum operator arm length a = Minimum length of slide channel b, c = Recommended hole dimensions 7

DORMA CD 400 For single-leaf doors CD 400, single leaf with etended cover LH and RH doors (Eample shows LH/ISO door on the pull side) min. mm 700 min. 4 mm 57 39,5 19 20, b* c* 270 *see page /7

Spindle etensions Installation type: Hinge side, pulling 2 V 109 (h1) h1 h1 = + 109 = 14, = 21,9 = 29,2 = 3,5 Standard = 0 Installation type: Opposite hinge side, pushing 2 V 0 (h1) h1 h1 = + 0 = 14, = 21,9 = 29,2 = 3,5 Standard = 0 Installation type: Hinge side, pulling y h2 h2 = y 9, Pin y h2 Standard: 10,4 1,4, y = 2, 20, 2, 19 31,2 39,2 29,4 41, 49, 39, y h2 19 (h2) 20, 2, (y) y h2 4 Pin lengths for the operator arm Installation type: Opposite hinge side, pushing 37, (h2) 10,4 h2 = y + 19,2 Pin y h2 Standard: 10,4 1,4 37, y = 1,4 20, 2, 4 31,2 39,2 5,4 41, 49,, 1,4 (y) 9

DORMA CD 400 For single-leaf doors Door leaf installation on the pull side with Softline slide channel LH and RH doors (Eample shows LH/ISO door) b = 70 c = 35 270 W = 370 20, 49(h2) 2 V 59 72 5 23 27(h1) 94 255,25 255,25 700 Z Door leaf installation on the push side with Softline slide channel LH and RH doors (Eample shows RH/ISO 5 door) b = 270 c = 70 270 W = 00 a = 723 57 (h1) 19 (h2) 20, 2 V 9 102 115 23 94 255,25 255,25 700 Z 10

Operator arm lengths with Softline slide channel 54 54 12 5 27 49 20 20 Installation type: Hinge side, pulling Z W a b c 120 20 750 370 52 70 35 Operator arm lengths with Softline slide channel 54 54 12 5 57 19 20 20 Installation type: Opposite hinge side, pushing Z W a b c 120 20 1000 00 723 270 70 = Frame reveal depth Z = Minimum door width W = Minimum operator arm length a = Minimum length of slide channel b, c = Recommended hole dimensions 11

DORMA CD 400 For double-leaf doors Installation on the pull side (with continuous cover) 2 V** 19 20, 57 39 b* c* 270 min. mm B min. = 1500 mm Installation on the push side (with continuous cover) 2 V** 47 9,5 37,5 10,4 b* c* 270 min. mm B min. = 1500 mm CD 400 with door co-ordinator The CD 400 can be mounted on both the pull and push side of fire and smoke check doors. There are various door co-ordinators available for both applications, and these have to be mounted on the side of the door set opposite to that on which the operator is installed. The DORMA RM-ED can be used as the control device for actuating the closing sequence in the event of a fire. The CD 400 can also be connected for the same purpose to fire alarm systems by others. In the event of a fire, the door co-ordinators ensure that, once the smoke detector has responded, double doors close in the right sequence. The active leaf is retarded to ensure that it closes after the inactive leaf. The illustration shows by way of eample the GSR door co-ordinator mounted on the push side (opposite hinge side) with the CD 400 installed on the pull side. Approval certification Approval certification relating to the use of the CD 400 on fire and smoke check doors plus ancillary information is available on request. 5 Eample: Active leaf LH/ISO door. RH/ISO 5 door is mirror image 123 470 107 Inactive leaf (min. 00 mm) 12

332,5 13 2 V** 5 20 470 15 5 51 19 113 0,5 a* min. mm 332,5 13 2 V** 5 20 37,5 22 4 0,5 a* min. mm * see page /7 **Power supply feed can be either from the left or right. 5 ma. 5 37,5 33 RM-ED 1500 2500 17 RM-ED 10 5 19 51 Active leaf 53 13 13 0,5 3,5 ma. 13

DORMA CD 400 For double-leaf doors Installation on pull side and push side (contraflow traffic) 700 94 255,25 255,25 2 V 52 39 50,2 (h2) 52 109 (h1) 15 0 35 270 Spindle etensions Spindle etensions for double-leaf contraflow variant Door model Hinge side operator, pulling Opposite hinge side operator, pushing Spindle etension Spindle etension With rebate at top 0.0 mm 3.5 mm Without rebate at top 0.0 mm 29.2 mm In all cases the difference between the spindle etensions must be constant for both operators. In the case of doors with top rebates, the difference therefore must always be 3.5 mm. For doors without top rebates the difference in spindle etension is smaller (29.2 mm). Installation type: Hinge side, pulling h1 2 V 109 (h1) Installation type: Opposite hinge side, pushing 109 (h1) h1 2 V 14

700 51 4 77 255,25 255,25 94 3,5 2 V 50,2 109 51 5 20 50,2 50,2 51 5 20 15,5 0,5 0,5 35 0 270 Pin lengths Pin lengths for operator arms for double-leaf contraflow variant Door model Hinge side operator, pulling Opposite hinge side operator, pushing Pin length of operator arm y h2 Pin length of operator arm y With rebate at top 52.0 mm 0.0 mm 50.2 mm 15.5 mm 23.5 mm Without rebate at top 41. mm 49. mm 39. mm 12.4 mm 20.4 mm h2 = y 9, *The relative heights of operator and slide channel on the push side are as per the specification for the operator/slide channel relationship on the pull side. Installation type: Hinge side, pulling y * y h2 Installation type: Opposite hinge side, pushing 15

DORMA CD 400 Wiring diagrams Connections for single-leaf system 13 4 0, mm 14 4 0, mm 4 0, mm 12 0, mm 4 0, mm CD 400 11 NYM 3 1,5 mm Tür zu 15 2 0, mm 2 0, mm 4 0,25 mm 4 0,25 mm 4 0, mm 2 0, mm 4 0, mm 3 5 9 4 10 7 2 10 A 1 L1 N PE 1 Feeder: 5 Pushbutton, internal 2 Emergency pushbutton Pushbutton, eternal 3 Two-pole-and-earth socketoutlet Radar, internal 7 Locking mechanism 4 EPGS-D DCW eternal 9 Radar, eternal program switch Connections for double-leaf system 10 Key switch 11 CD 400 12 RM-ED or RM 13 Ceiling-mounted smoke detector, opposite hinge side 14 Ceiling-mounted smoke detector, hinge side 15 Manual door release mechanism 13 4 0, mm 4 0, mm 4 0, mm 12 0, mm 2 0, mm 2 0, mm CD 400 11 14 NYM 3 1,5 mm Inactive leaf Active leaf 2 0, mm 2 0, mm 4 0,25 mm 4 0,25 mm 4 0, mm 2 0, mm 4 0, mm 3 Tür zu 15 7 5 9 4 10 2 10 A 1 L1 N PE 1 Feeder: 2 Emergency pushbutton 3 Two-pole-and-earth socketoutlet 4 EPGS-D DCW eternal program switch 5 Pushbutton, internal Pushbutton, eternal 7 Locking mechanism Radar, internal 9 Radar, eternal 10 Key switch 11 CD 400 12 RM-ED or RM 13 Ceiling-mounted smoke detector, opposite hinge side 14 Ceiling-mounted smoke detector, hinge side 15 Manual door release mechanism 1

Emergency eit security system The door is normally locked (DORMA TV 100, TV 500). Operation of the emergency pushbutton in the DORMA TL terminal causes the locking mechanism to be de-energised and released, and also the deadbolt and latch of the DORMA SVP 2000 emergency escape lock to be withdrawn and enabled respectively. At the same time, the system emits an alarm and the DORMA CD 400 receives an opening signal. Authorised personnel can unlock the door using the momentary contact key switch of the DORMA TL, or via DORMA access control systems such as CODIC-CARD. If the DORMA RM smoke detector responds, the DORMA TV is unlocked, the DORMA SVP 2000 anti-panic lock with automatic locking action is locked and the DORMA CD 400 is de-energised. These actions ensure that the fire protection characteristics of the door are maintained. If activated from a central control position, the TV and the SVP 2000 are unlocked and the CD 400 opens the door. German MPA and VdS (insurance) approval certificates for use in emergency eit and escape routes have been issued for this system. RM BMA DCW junction bo CD 400 KÜ SVP 2000 SVP-A TV DCW TL TMS ACU 01 SVP DCW I/O DCW UP Concealed bo CRH-BDCW TMS Universal Insurance lock When closed, the door is locked by the DORMA SVP 2000 emergency eit motor lock with automatic locking action (insurance lock). The door can be opened and closed from the inside at any time, with unlocking of the DORMA SVP 2000 and delayed activation of the DORMA CD 400 being initiated either manually or by active detectors as required. Activation control from a central position is also possible. The CRM-B DCW CODIC Card reader enables access from outside for authorised persons. Once the door is closed, the insurance lock is reinstated fully automatically as the DORMA SVP 2000 automatically throws the bolt after each closing cycle. The motor lock control module DORMA SVP-S22 is installed in the etended cover of the CD 400 for activation control of the DORMA SVP 2000. CD 400 + SVP-S 22 TK 2/0 DCW SVP 2000 ACU 01 SVP DCW I/O DCW CRH-BDCW CD 400 with Softline slide channel 17

DORMA CD 400 Sensor slide channel SSCD Features and benefits 2 Integrated motion detectors simple activation from a distance of appro. 4 m repeat opening signal initiated with the door half opened 2 No additional eternal installation of radar motion detectors and infra-red safety sensors 2 Simple solution offering easy installation even in problematic situations Operating principles 740 9 49 SSCD functional description and applications Integrated radar motion detectors 2 On activation, the infra-red safety sensors of the SSCD initiate a stop function when fitted on the pull side reverse the door when fitted on the push side 2 On activation, radar motion detectors integrated in the SSCD (pull side fiing only) emit an opening signal at any door opening angle 2 Installation of the integrated sensors: fiing on the pull side: infra-red safety sensors and 2 radar motion detectors fiing on the push side: infra-red safety sensors 2 Technical system: Merkur radar motion detector 2 Detection cone length ma. 4.25 m 2 Operating temperature from 20 C to +0 C Integrated infra-red safety sensors 2 Technical system: of the DORMA IRS-2 safety sensor 2 Background blanking function 2 Detection distance setting adjustable from 1500 mm to 2500 mm 2 Operating temperature from 20 C bis +0 C Reversal 1

CD 400 with SSCD sensor slide channel on a singleleaf door Accessories Merkur radar motion detector EPGS-D DCW electronic program switch (compatible with DCW bus) Handheld computer for servicing and commissioning with DORMA Automatic Service Program (ASP) DORMA IRS-2 infra-red safety sensor for protection of the door sweep range. Standard lengths: 3, 770, 0 and 1200 mm. Large pushbutton, flush or surface mounted 19

Swing door operator DORMA CD 400 Ordering guide Ordering guide: Choosing the right operator arms and slide channels Single-leaf operator (Same selection procedure applies for double-leaf operators. Selection procedure for accessories for contraflow models is described on Pages 14 and 15) 1. Select application, i.e. decide on type of fiing (hinge side/opposite hinge side) and choose slide channel (SSCD sensor slide channel or Softline slide channel) 2. Depending on the application selected in Step 1, select the appropriate application diagram and table from Pages 4 11. 3. Select the appropriate row in the table based on frame reveal depth. Selecting this table row determines the following: 2 Min. door width Z: Minimum door width Z is required for the relevant application. 2 Min. operator arm length W: Minimum arm length W is required for the relevant application. If the door width is sufficiently large, a longer operator arm can be used. Caution! If you need a longer main arm, you may also need a longer slide channel. 2 Min. slide channel length a: A minimum slide channel length a is required for the relevant application. If the door width is sufficiently large, a longer slide channel can be used. Particularly when using the SSCD sensor slide channel, a maimum length should be selected in line with the door width so as to ensure that the entire door sweep range is protected by the integrated safety sensors. 4. With hinge-side installation of the CD 400 the standard pin length of the operator arm is 20. mm. If the operator is installed on the side opposite the hinge, a standard pin length of 10.4 mm is recommended. The effects of varying the pin length are shown in the illustrations on Page 9. Practical eample Installation type: Hinge side, pulling Z W a b c 40 < 0 00 370 740 110 05 0 < 0 0 40 740 210 05 0 200 1100 00 740 420 05 Recommended hole dimension b Minimum operator arm length W Recommended hole dimension c Minimum slide channel length a Minimum door width Z The above illustration shows the installation of the CD 400 on the hinge side (pulling) in combination with an SSCD sensor slide channel. For frame reveal depths of 0 mm to 0 mm a min. door leaf width of Z = 0 mm is needed. In addition, a min. operator arm length of W = 40 mm and a min. length of sensor slide channel of a = 740 mm are needed. (Recommended hole sizes of b = 210 mm and c = 05 mm apply.) If the door widths are sufficiently large, a longer operator arm and longer slide channel can be used. The sizes of the holes would then increase accordingly. The standard pin length of the operator arm for hinge-side installation is 20. mm. All required accessories are defined in the above details. 20

Swing door operator DORMA CD 400 Single-leaf model, standard doors Specification tets Door parameters: 2 Clear passage width: 750 mm to 0 mm 2 Door leaf weight: ma 10 kg 2 Opening angle: ma 110 2 Operator dimensions (height depth width) mm mm 700 mm 2 Function programs: OFF AUTOMATIC EIT ONLY PERMANENT OPEN (rated for continuous duty) 2 Power supply data: 2 V AC, 50/0 Hz, CD 400 can be installed on the hinge side (pulling) or opposite hinge side (pushing) Force transmission with slide channel assembly only Electro-mechanical operator for swing doors with electronic control and integrated door closer; manual operation of door possible in the event of a power failure; tested and quality third-party verified to DIN 123, Part 4. Door closer function remains intact in the event of power failure or disconnection. Closing force EN 5 to EN 1154. Parameterisation of customer-specific configuration via handheld computer: hold-open time infinitely variable from 0 to 10 s, variable opening and closing speeds, force limitation on detection of obstruction, latching/delatching action in Close and Open cycles, Push & Go function, Low Energy mode, operating behaviour in accordance with pren 1250. Manufactured and tested in accordance with German code of practice ZH 1/494 governing power-operated windows, doors and gates, German UVV (accident prevention) regulations, the EU machinery, EMC and low-voltage directives (CE mark) and VDE (Association of German Engineers) regulations (latest edition in each case). Quality-assured manufacture, registered to ISO 00. In the case of fire doors, ensure compliance with the relevant approval certificate in each case! Selected accessories Safety equipment 2 Infra-red safety sensors for protection of the sweep range as per German code ZH 1/494: ( ) IRS-2-33 ( ) IRS-2-70 ( ) IRS-2- ( ) IRS-2-120/2 ( ) IRS-2-120/3 2 SSCD sensor slide channel assembly; combination of infra-red safety sensors for protection of the sweep range, radar motion detectors as activators and slide channel: SSCD with 2 integrated infra-red safety sensors and 2 radar motion detectors (pull-side fiing only!): ( ) Length 740 mm ( ) Length 40 mm ( ) Length 940 mm Colour: ( ) silver ( ) RAL 10 ( ) RAL 1 ( ) similar to RAL =... 2 SSCD with 2 integrated infra-red safety sensors (suitable for fiing on push side and pull side) ( ) Length 740 mm ( ) Length 40 mm ( ) Length 940 mm Colour: ( ) silver ( ) RAL 10 ( ) RAL 1 ( ) similar to RAL =... Activators: ( ) radar motion detectors ( ) pushbuttons Service options: ( ) Installation ( ) Commissioning ( ) Service Agreement Model (incl. mounting backplate): ( ) LH/ISO ( ) RH/ISO 5 Installation of operator: ( ) push side (opposite hinge side) ( ) push side (hinge side) Frame reveal depth: ( ) Dimension =... mm ( 40 mm to 200 mm) Etended cover: ( ) Dimension =... mm (min. etension /4 mm) Colour: Standard: ( ) silver ( ) RAL 10 ( ) RAL 1 Special colours: ( ) similar to RAL =... Emergency pushbutton to DIN VDE installed in vicinity of door: Type: ( ) emergency off ( ) emergency stop Mounting method: ( ) concealed/flush-mounted ( ) surface-mounted Program selectors: ( ) internal (standard) ( ) eternal, 5 modes Mounting method: ( ) concealed/flush-mounted ( ) surface-mounted 21

Swing door operator DORMA CD 400 Double-leaf model, standard doors Specification tets Door parameters: 2 Clear passage width: 1500 mm to 200 mm 2 Door leaf weight: ma 10 kg 2 Opening angle: ma 110 2 Operator dimensions (height depth width) mm mm 700 mm 2 Function programs: OFF AUTOMATIC EIT ONLY PERMANENT OPEN (rated for continuous duty) 2 Power supply data: 2 V AC, 50/0 Hz, CD 400 can be installed on the hinge side (pulling) or opposite hinge side (pushing) Force transmission with slide channel assembly only Electro-mechanical operator for swing doors with electronic control and integrated door closer; manual operation of door possible in the event of a power failure; tested and quality third-party verified to DIN 123, Part 4. Door closer function remains intact in the event of power failure or disconnection. Closing force EN 5 to EN 1154. Parameterisation of customer-specific configuration via handheld computer: hold-open time infinitely variable from 0 to 10 s, variable opening and closing speeds, force limitation on detection of obstruction, latching/delatching action in Close and Open cycles, nurse/bed control, Push & Go function, Low Energy mode, operating behaviour in accordance with pren 1250. Manufactured and tested in accordance with German code of practice ZH 1/494 governing power-operated windows, doors and gates, German UVV (accident prevention) regulations, the EU machinery, EMC and low-voltage directives (CE mark) and VDE (Association of German Engineers) regulations (latest edition in each case). Quality-assured manufacture, registered to ISO 00. In the case of fire doors, ensure compliance with the relevant approval certificate in each case! Selected accessories Safety equipment 2 Infra-red safety sensors for protection of the sweep range as per German code ZH 1/494: ( ) IRS-2-33 ( ) IRS-2-70 ( ) IRS-2- ( ) IRS-2-120/2 ( ) IRS-2-120/3 2 SSCD sensor slide channel assembly; combination of infra-red safety sensors for protection of the sweep range, radar motion detectors as activators and slide channel: SSCD with 2 integrated infra-red safety sensors and 2 radar motion detectors (pull-side fiing only!): ( ) Length 740 mm ( ) Length 40 mm ( ) Length 940 mm Colour: ( ) silver ( ) RAL 10 ( ) RAL 1 ( ) similar to RAL =... 2 SSCD with 2 integrated infra-red safety sensors (suitable for fiing on push side and pull side) ( ) Length 740 mm ( ) Length 40 mm ( ) Length 940 mm Colour: ( ) silver ( ) RAL 10 ( ) RAL 1 ( ) similar to RAL =... Activators: ( ) radar motion detectors ( ) pushbuttons Service options: ( ) Installation ( ) Commissioning ( ) Service Agreement Installation of operator: ( ) push side (opposite hinge side) ( ) push side (hinge side) Frame reveal depth: ( ) Dimension =... mm ( 40 mm to 200 mm) Etended cover: ( ) Dimension =... mm Colour: Standard: ( ) silver ( ) RAL 10 ( ) RAL 1 Special colours: ( ) similar to RAL: =... Emergency pushbutton to DIN VDE installed in vicinity of door: Type: ( ) emergency off ( ) emergency stop Mounting method: ( ) concealed/flush-mounted ( ) surface-mounted Program selectors: ( ) internal (standard) ( ) eternal, 5 modes Mounting method: ( ) concealed/flush-mounted ( ) surface-mounted 22

Swing door operator DORMA CD 400 Single-leaf model, fire and smoke check doors Specification tets Door parameters: 2 Clear passage width: 750 mm to 1250 mm 2 Door leaf weight: ma 10 kg 2 Opening angle: ma 110 2 Operator dimensions (height depth width) mm mm 700 mm 2 Function programs: OFF AUTOMATIC EIT ONLY PERMANENT OPEN (rated for continuous duty) 2 Power supply data: 2 V AC, 50/0 Hz, CD 400 can be installed on the hinge side (pulling) or opposite hinge side (pushing) Force transmission with slide channel assembly only Electro-mechanical operator for swing doors with electronic control and integrated door closer; manual operation of door possible in the event of a power failure; tested and quality third-party verified to DIN 123, Part 4. Door closer function remains intact in the event of power failure or disconnection. Closing force EN 5 to EN 1154. Parameterisation of customer-specific configuration via handheld computer: hold-open time infinitely variable from 0 to 10 s, variable opening and closing speeds, force limitation on detection of obstruction, latching/delatching action in Close and Open cycles, Push & Go function, Low Energy mode, operating behaviour in accordance with pren 1250. Manufactured and tested in accordance with German code of practice ZH 1/494 governing power-operated windows, doors and gates, German UVV (accident prevention) regulations, the EU machinery, EMC and low-voltage directives (CE mark) and VDE (Association of German Engineers) regulations (latest edition in each case). Quality-assured manufacture, registered to ISO 00. In the case of fire doors, ensure compliance with the relevant approval certificate in each case! Model (incl. mounting backplate): ( ) LH/ISO ( ) RH/ISO 5 Installation of operator: ( ) push side (opposite hinge side) ( ) push side (hinge side) Frame reveal depth: ( ) Dimension =... mm (0 mm to 200 mm) for pull side fiing ( ) Dimension =... mm (0 mm to 100 mm) for push side fiing Etended cover: ( ) Dimension =... mm (min. etension mm/4 mm) Colour: Standard: ( ) silver ( ) RAL 10 ( ) RAL 1 Special colours: ( ) similar to RAL: =... Emergency pushbutton to DIN VDE installed in vicinity of door: Type: ( ) emergency off ( ) emergency stop Mounting method: ( ) concealed/flush-mounted ( ) surface-mounted Program selectors ( ) internal (standard) ( ) eternal, 5 modes Mounting method: ( ) concealed/flush-mounted ( ) surface-mounted Smoke detector: DORMA RM 2 Quantity: 1 RM where bottom surface of frame reveal/lintel to underside of smoke-proof ceiling < 1 m 2 Plus: 2 RM where bottom surface frame reveal/lintel to underside of smoke-proof ceiling > 1 m 2 Palm switch Close Door as per German DIBt regulations Selected accessories Safety equipment 2 Infra-red safety sensors for protection of the sweep range as per German code ZH 1/494: ( ) IRS-2-33 ( ) IRS-2-70 ( ) IRS-2- ( ) IRS-2-120/2 ( ) IRS-2-120/3 2 SSCD sensor slide channel assembly; combination of infra-red safety sensors for protection of the sweep range, radar motion detectors as activators and slide channel: SSCD with 2 integrated infra-red safety sensors and 2 radar motion detectors (pull-side fiing only!): ( ) Length 740 mm ( ) Length 40 mm ( ) Length 940 mm Colour: ( ) silver ( ) RAL 10 ( ) RAL 1 ( ) similar to RAL =... 2 SSCD with 2 integrated infra-red safety sensors (suitable for fiing on push side and pull side) ( ) Length 740 mm ( ) Length 40 mm ( ) Length 940 mm Colour: ( ) silver ( ) RAL 10 ( ) RAL 1 ( ) similar to RAL =... Activators: ( ) radar motion detectors ( ) pushbuttons Service options: ( ) Installation ( ) Commissioning ( ) Service Agreement 23

Swing door operator DORMA CD 400 Double-leaf model, fire and smoke check doors Specification tets Door parameters: 2 Clear passage width: 1500 mm to 2500 mm 2 Door leaf weight: ma 10 kg 2 Opening angle: ma 110 2 Operator dimensions (height depth width) mm mm 700 mm 2 Function programs: OFF AUTOMATIC EIT ONLY PERMANENT OPEN (rated for continuous duty) 2 Power supply data: 2 V AC, 50/0 Hz, CD 400 can be installed on the hinge side (pulling) or opposite hinge side (pushing) Force transmission with slide channel assembly only Electro-mechanical operator for swing doors with electronic control and integrated door closer; manual operation of door possible in the event of a power failure; tested and quality third-party verified to DIN 123, Part 4. Door closer function remains intact in the event of power failure or disconnection. Closing force EN 5 to EN 1154. Parameterisation of customer-specific configuration via handheld computer: hold-open time infinitely variable from 0 to 10 s, variable opening and closing speeds, force limitation on detection of obstruction, latching/delatching action in Close and Open cycles, nurse/bed control, Push & Go function, Low Energy mode, operating behaviour in accordance with pren 1250. Manufactured and tested in accordance with German code of practice ZH 1/494 governing power-operated windows, doors and gates, German UVV (accident prevention) regulations, the EU machinery, EMC and low-voltage directives (CE mark) and VDE (Association of German Engineers) regulations (latest edition in each case). Quality-assured manufacture, registered to ISO 00. In the case of fire doors, ensure compliance with the relevant approval certificate in each case! Installation of operator: ( ) push side (opposite hinge side) ( ) push side (hinge side) Frame reveal depth: ( ) Dimension =... mm (0 mm to 200 mm) Etended cover: ( ) Dimension =... mm (min. etension mm) Colour: Standard: ( ) silver ( ) RAL 10 ( ) RAL 1 Special colours: ( ) similar to RAL: =... DORMA Entrance Systems Limited Woodside Industrial Park Works Road GB-Letchworth Hertfordshire SG 1LA Tel. 0142 40544 Fa 0142 405 DORMA Door Controls Pte. Ltd. No. 2, Jalan Terusan, Jurong Singapore 1925 Rep. of Singapore Tel. 005 2733 Fa 005 257914 BWN Industries Pty. Ltd. 4 Abbott Road Hallam Victoria 303 Australia Tel. 001 3/97 9 41 11 Fa 001 3/97 9 37 7 DORMA Door Controls Pty. Ltd. P.O. Bo 1092 Narre Warren Vic 305 52 Abbott Road Hallam Victoria 303 Australia Tel. 001 3/97 9 35 55 Fa 001 3/97 9 39 55 Emergency pushbutton to DIN VDE installed in vicinity of door: Type: ( ) emergency off ( ) emergency stop Mounting method: ( ) concealed/flush-mounted ( ) surface-mounted Program selectors: ( ) internal (standard) ( ) eternal, 5 modes Mounting method: ( ) concealed/flush-mounted ( ) surface-mounted Smoke detector:dorma RM 2 Quantity: 1 RM where bottom surface of frame reveal/lintel to underside of smoke-proof ceiling < 1 m 2 Plus: 2 RM where bottom surface frame reveal/lintel to underside of smoke-proof ceiling > 1 m 2 Palm switch Close Door as per German DIBt regulations Selected accessories Safety equipment 2 Infra-red safety sensors for protection of the sweep range as per German code ZH 1/494: ( ) IRS-2-33 ( ) IRS-2-70 ( ) IRS-2- ( ) IRS-2-120/2 ( ) IRS-2-120/3 2 SSCD sensor slide channel assembly; combination of infra-red safety sensors for protection of the sweep range, radar motion detectors as activators and slide channel: SSCD with 2 integrated infra-red safety sensors and 2 radar motion detectors (pull-side fiing only!): ( ) Length 740 mm ( ) Length 40 mm ( ) Length 940 mm Colour: ( ) silver ( ) RAL 10 ( ) RAL 1 ( ) similar to RAL =... 2 SSCD with 2 integrated infra-red safety sensors (suitable for fiing on push side and pull side) ( ) Length 740 mm ( ) Length 40 mm ( ) Length 940 mm Colour: ( ) silver ( ) RAL 10 ( ) RAL 1 ( ) similar to RAL =... Activators: ( ) radar motion detectors ( ) pushbuttons Service options: ( ) Installation ( ) Commissioning ( ) Service Agreement DORMA Gulf Door Controls FZE Jebel Ali Free Zone, Roundabout, Unit VC 02 P.O. Bo 172 Jebel Ali,Dubai United Arab Emirates Tel. 00971 4 /3 14 Fa 00971 4 /3 15 DORMA Door Controls (Pty.) Ltd. Kings Court P.O. Bo 212 2135 Southdale South Africa Tel. 0027 11/ 02 0 Fa 0027 11/ 02 91 DORMA GmbH + Co. KG P.O. Bo 40 09 5247 Ennepetal Breckerfelder Straße 42-4 525 Ennepetal Germany Tel. +49(0)23 33/7 93-0 Fa +49(0)23 33/79 34 95 The address of a subsidiary/ representation in your area you can find at the DORMA website: www.dorma.com WN 052 14 51532, 03/03, CD 400, GB,. /CtP. 04/03 Subject to change without notice