MYTHBUSTERS! Background. Stakes. Steam Heating System Design Episode

Similar documents
Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

CSI Customer. From: Controls Southeast, Inc. Date: Feb ControTrace Heating System for 110 ft Diameter Sulfur Tank.

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

Steam Trap Inspection Methods And Steam Cost Analysis

UNIVERSAL STYLE STEAM TRAPS WU450 Series

Pure Performance For Steam Mains and Tracers

APPLICATION GUIDELINES STEAM MAIN DRAINAGE

Economical and simplified solutions that offer quality and optimum steam trap service.

Why steam trap survey?

CSI provides thermal maintenance systems for heating and cooling of liquid/vapour processes in the petrochemical, chemical, and refining industries.

Energy Savings. ISO9001

Minimizing Corrosion in SRU Vapor Lines

BASICS OF STEAM TRAPS BASICS OF STEAM TRAPS

Chapter 2.3: Steam System

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

GESTRA Information A 1.5

KEEP YOUR TRAP SHUT OR GET THE CONDENSATE OUT

Heater Inspection Guidelines

HumidiPack,HumidiPackPlus and HumidiPackPlus CF Steam Humidifier Systems

STAINLESS STEEL TRAP VALVE STATION

How to Trap: Trap Selection and Safety Factors

Steam Traps and Steam Specialties

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

PIP PNE00004 Steam Trap Guidelines

How to Trap: Rotating Dryers Requiring Syphon Drainage

How to Trap: Steam Tracer Lines

STEAM TRAPS FOREST PRODUCTS LIBRARY FOREST RESEARCH LABORATORY OREGON STATE UNIVERSITY. Information Reviewed and Reaffirmed. August No.

INDUSTRIAL HEAT TRACE

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

Hydrocarbon & Chemical Processing Solutions

Eliminating Condensation and Resulting Corrosion. Sulphur Tail Gas and De-Gas Lines

Boiler Steam Supply Piping Basics November 18, ) Q: What kind of condensate traps should be used on vacuum condensate return systems?

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

Efficient Steam System Design

PRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control.

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

Steam Trap Selection

A M E M B E R O F T H E K E N D A L L G R O U P

MAXIFLO EJECTOR SYSTEM AN INNOVATIVE APPROACH TO STEAM CONSERVATION LEVEL 4 BEE ACCREDITED

Steam Site Guide. Steam Site Guide. Heat Exchange Applications - SI Units

PRESSURE MOTIVE PUMP (PMP) APPLICATIONS

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

THE THERMOSTATIC STEAM TRAP

Bringing Energy Down to Earth

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Refrigeration Basics from a Brewery Perspective

How to Trap: Installation and Testing

How to Trap: Conversion Factors

STEAM CONSERVATION GUIDELINES

How to Trap: Process Air Heaters

Liquid Drainers LIQUID DRAINERS

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

Installation and Testing of Inverted Bucket Steam Traps Manual

Pure Performance For Steam Mains and Tracers

How to Trap: Troubleshooting

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS UNIT OBJECTIVES

Armstrong Steam System Solutions for the Hydrocarbon and Chemical Processing Industries

CD-33/CD-33S Controlled Disc Steam Traps

THERMODYNAMIC STEAM TRAPS

Steam Conservation Guidelines for Condensate Drainage Steam Trap Sizing and Selection.

1 of 127. Unicron Engineering ULTRASONIC TRAP TESTER UTT 100 CONDENSATE DRAIN VALVES CDV 32

LIQUIDATOR UMT-TD Series Thermodynamic

STEAM TRAPS

Series 1140 and 1141 Temperature Regulators

Contents. Preface... xvii

Weather: Why do we have weather? Does it serve a purpose?

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (May 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

THERMODYNAMIC STEAM TRAPS

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

Owner s Manual Phoenix 200HT

Steam and Condensate Pipe Sizing Health Care Example: Steam and Steam Heat Exchangers Basics (Part 7)

THE PRESSURIZED CONDENSATE RECOVERY SYSTEM:

The right trap for the right application.

GESTRA. Steam traps and monitoring equipment. The right choice in every case

TESTING STEAM TRAPS TO KEEP YOUR SYSTEM OPERATING EFFECTIVELY AND EFFICIENTLY

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Hoffman Specialty General Catalog

ANNEX 6. Refinery No. 1 New Area. Problems Existing in the Current Condensate Return System of the New Area of Refinery No.1

5. ASSESSMENT RECOMMENDATIONS

Blowdown Separator & Aftercoolers

A few simple steps to ensure perfect water, every time.

Cyclonic Separator. Condensate Separator. No Air Loss Drain. Condensate Management. People. Passion. Performance.

Owner s Manual Phoenix 250 MAX

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

STEAM TRAP HEALTH MONITORING SERVICE EXECUTIVE SUMMARY

Steam Conservation Guidelines for. Drainage. Mead O'Brien (800) LP Steam. Condensate. HP Steam RECEIVER TANK HEATER

Jet Compressors. Circulate Steam Boost Low-Pressure Steam Compress and Mix Gases in Desired Proportion

Owner s Manual Phoenix 250 MAX

Inverted bucket steam traps Type OKZ PN6/PN16

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

Steam trapping overview STEAM & CONDENSATE MANAGEMENT SOLUTIONS

Transcription:

September 13-17, 2010 Alberta, Canada MYTHBUSTERS! Steam Heating System Design Episode Jim Hartman Controls Southeast, Inc. Background Sulfur needs to be maintained within narrow temperature range to preserve flow Most common approach is steam heating Steam transfers heat to sulfur via jacketing Someone must design how Steam is transported to the heating system Steam is routed through the system Condensate is removed from the system Steam system design is often left to industry myths instead of engineering design 2 Stakes Process performance CAPEX savings OPEX savings Less maintenance/repair events 3

Agenda Three common myths Myth Basis for myth Real-life example that illustrates myth Evaluation Lessons learned Steam jacketed systems for liquid sulfur lines 4 Myth If the sulfur lines are flowing, my heating system must be working. 5 Basis for myth If it s flowing, it s not plugged Thermodynamics: hot piping will lose heat to cooler surroundings As process loses heat, its temperature can drop below sulfur freezing point, causing plugging Flowing process loses more heat than no-flow 6

Real-life example #1 2.5 mile sulfur transfer line in Kazakhstan Design/install enough tracing to keep sulfur molten at end of line Minimize heat input to sulfur prior to forming unit Design details: 8-in NPS 2.5-in mineral wool Ambient conditions: -40 F/ 25mph wind 3 fps flow rate Sulfur enters line at 284 F 7 Temperature ( F) 300 290 280 270 260 Evaluation: flowing Sulfur Flowing Through Transfer Line Without Heating Sulfur Temperature Sulfur Freezing Point 250 240 0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 Distance (ft) 8 300 270 Evaluation: no-flow Sulfur Temperature Over Time Without Heating Temperature ( F) 240 210 180 150 120 90 Sulfur Freezing Point Sulfur Temperature 60 0 10 20 30 40 Time (hr) 9

Real-life example #2 Consider this heating piping system 10 Myth If the sulfur lines are flowing, my heating system must be working. 11 Lessons learned 1. Flowing, insulated sulfur lines do not need heat 2. Real design requirement is no-flow and melt-out 12

Myth Condensate must be trapped after every JP spool. 13 Basis for myth Water seeks its own level Gravity causes water to run downhill Concern that condensate which drains out of spool and into jumper will prevent free flow of steam into next JP spool 14 Real-life example Taken from JP specification for 640-spool project Requires 1 trap per spool 15

Evaluation: steam video 16 Myth Condensate must be trapped after every JP spool. 17 Lessons learned 1. Condensate does not stop steam flow 2. Real limitation on trap frequency (circuit length) is steam pressure Temperature (F) 450 400 350 300 250 200 150 Saturated Steam 0 50 100 150 200 250 Pressure (psig) 18

Lessons learned 3. Removing the trap every spool requirement can save lots of traps and $ w/o impacting performance Trap Qty CAPEX $ OPEX $/Yr 1 trap / spool 640 $624,000 $85,333 CSI design 148 $144,300 $19,733 Δ 492 $479,700 $65,600 Assumptions: $975 CAPEX/trap; 3 year trap life; $400 replacement cost including labor. 19 Myth A jacketed heating system will work with any type of standard steam trap. 20 Basis for myth All traps share same basic objective: Trap steam Remove condensate Many types of traps Differences can be complicated Many have not taken the time to understand the differences or implications 21

Real-life example New Alberta SRU Extensive freeze-ups during first winter Found 34 disc traps failed closed due to debris Found 19 disc traps failed open due to high back pressure Changed 550 traps to inverted bucket traps No issue during next winter 22 Inverted Bucket Trap styles Thermodynamic (disc) Float Thermostatic 23 Trap requirements Remove condensate Continuously purge entrained air Accommodate condensate return back pressure 24

Trap recommendations Type Performance Recommendation IB Float Disc TS Recommended No special considerations Acceptable if consider air purging May be acceptable if consider condensate return pressure correctly Not acceptable Condensate can back up in jacketing/tubing 25 Myth A jacketed heating system will work with any type of standard steam trap. 26 Summary 1. Design liquid sulfur lines for no-flow/melt-out 2. Design steam circuits using engineering rather than rules-of-thumb to save traps, $, and issues 3. Choose inverted bucket or float/thermostatic steam trap for maximum robustness 27

Thank you! 28 Controls Southeast, Inc. Charlotte, NC www.csiheat.com