IFU 005 CLEANING / PREPARATION OF OUTDOOR HEAT EXCHANGE SURFACES & COILS. Date Approved

Similar documents
2. PROCEDURE DESCRIPTION AND PROCESS FLOW

Section 2. Product overview & label familiarisation

BIOACTIVE COIL TREATMENT FOR TREATMENT OF AIR CONDITIONING HEAT EXCHANGE COILS

Maintain and restore hard floors

Personal Protective Equipment. Shawn Appling Associate Extension Agent, Culpeper County Office Serving Culpeper, Madison, and Orange

OPERATING INSTRUCTIONS FOR THE TP18SX-HP

IS YOUR AIR CONDITIONER MAKING YOUR FAMILY SICK?

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

Product Application Sheets

1 of 12. Spring Delights Sdn. Bhd. K HIGH PRESSURE WASHER K HIGH PRESSURE WASHER

Commit 2 Clean TM/MC. Bloodborne Pathogens Awareness Program

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

CODE OF PRACTICE. No 11 CLEANING OF EQUIPMENT AND PREMISES

Materials to Restrict Access and Cover the Floor/Ground Signs

triple7 Municipal Environmental Solutions

STANDARD OPERATING PROCEDURE

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

METHOD STATEMENT INFORMATION REQUIRED

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

For routine maintenance of polished granite installations with a cleaner and protector:

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

Massachusetts Work Practices for Lead-safe Renovation

EQGA AND EQGB HYGIENIC VERSION, CODE SUFFIX I = 3 AND 4

Workbook Clean floors

Methods & Procedures. Operational Cleaning

Cleaning and Sanitation Procedures Module Deli

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

Pesticide Applicator Equipment Cleaning to Prevent Carryover. Chuck Schuster University of Maryland Extension

HVAC 101: Residential Typical system components & cleaning techniques

Mental Aspects. Methods, Techniques, Procedures

Daikin Water Cooling, Heating, and High Capacity Booster Coils

MAKE CLEANING SAFER NEW TECHNOMELT. Your Machine Cleaning Guide & Hotmelt Cleaner Range

BIOACTIVE SURFACE TREATMENT

Here s How 1,500 RPM Equals 100% Safety

IMPORTANT SAFEGUARDS WARNING

Washroom care programs

Recommended Floor Care Procedures

POISON S6 NOT TO BE TAKEN KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

READ AND SAVE THESE INSTRUCTIONS DE-SCALING SOLUTION. Humidifier De-scaling Solution and Neutralizer. Usage Instructions

Index. + Kleen Kote 200 Concentrate. + Kleen Krete. + Real Pump Power Spraying System. + Real Pump EXPRESS Portable Power Spraying System

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

DRAFT. Module 4. Decontamination & Environmental Cleaning

Guidelines to Minimize Phytophthora Contamination in Restoration Projects

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

Safety procedures: Wear your PPE. Gloves and goggles when filling the chemical bottle, using the machine, and cleaning the machine.

Developed by. Cleaning and Sanitation

Nu-Brite Same popular Nu-Brite Powerful high foaming action lifts out dirt and grime while brightening coils Excellent & powerful cleaner that is espe

BREAKTHRU Heavy Duty Liquid Detergent for Removal of Fatty Soils from Hard Surfaces

A powerful organic cleaner and degreaser that enhances workplace safety without compromising performance.

Method Statement. Supervisor/Cleaning operative Cleaning operative

CLEACOM Engineered System Solutions. Established 24/7 technology for the separation of dust and fume during compounding processes

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

K Specifications. Max. Water Volume

Portable Dust Collection Systems

Washroom care programs

Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers

Daikin Direct Expansion (DX) Cooling Coils

Trooper Portable Carpet Extractor. Operator and Parts Manual. Model No.: Can Rev. 00 (09-99)

1.01 General requirements of the Project Manual shall apply to all work specified in this section.

Transportation, Storage, and Spill Response. Pesticide Recertification Shawn Appling, Associate Extension Agent VCE-Culpeper

SRSS Cleaning and Sanitisation Procedure

How to Maintain Your Resin Floor

A. General Safety LAB/ROOM: INSPECTED BY: DATE:

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

MAKE CLEANING SAFER NEW TECHNOMELT. Your Machine Cleaning Guide & Hotmelt Cleaner Range

CLEANING INSTRUCTIONS

Device Reprocessing Checklist Scoring Matrix 1=low 5=high

OPERATION AND INSTRUCTION MANUAL NORCLEAN POWERED EDDY CURRENT VACUUM RECOVERY SYSTEM WITH WATER TRAP OPTION

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

FLOOR FINISH. Extended Performance Floor Finish

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

Washroom. PURPOSE: To provide clean washrooms for staff, visitors and patients MATERIALS: 19-1

Electric Pressure Washer

Restrooms. Proper daily cleaning procedures. Custodial Best Practices

PERFORM Operating Document

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

Maitenance guide N 3. for oiled DI LEGNO parquet floors white finishing

CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE:

MELBOURNE ADELAIDE SYDNEY BRISBANE PERTH

Explorer CleaningPartsDirect.com Carpet Extractor. Operator and Parts Manual. Home Find... Go To.. Model No.: Can.

SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12

SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80

User information. Cleaning/descaling and sanitizing

B.) Accident -- Any suddenly occurring unintentional event which causes injury or property damage.

Rules for Safe Operation

Bedroom Cleaning Standards: Sunrise Village

Laboratory Glassware Cleaning and Storage

Installation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010

Xaact Spot. Xaact Hot Spot

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

Work-Shed Vac 1100 Watt

K Specifications. Max. Water Volume

SpeedClean. Work Smarter NEW! Innovative cleaning products for maximum HVAC system efficiency. Innovative Maintenance Tools.

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

HOTSPOT. Two Gallon Pump Up Spotter OPERATING & MAINTENANCE

PROLAQ. New product for Cleaning solution for water & solvent based paints, varnishes & inks MAKING GREEN WORK.

PRE INSTALLATION PROCEDURES

Transcription:

CLEANING / PREPARATION OF OUTDOOR HEAT EXCHANGE SURFACES & COILS Document Type / Category Information for Use (IFU) / Clean & Prepare Outdoor Heat Exchange Coils & Surfaces Document Number 09-06-005 Document Title CLEANING, PREPARATION OF OUTDOOR HEAT EXCHANGE COILS & SURFACES Issue 2.1 (21/09.2016) Issue Description Date Author by 2.1 Information for Use document (IFU) 21/09/2016 D. Kritzler M. Kritzler 1. PURPOSE This Cleaning and Preparation Procedure outlines the process to effectively Clean and Prepare OUTDOOR Surfaces and Heat Exchange Coils. This provides 2 outcomes; - A clean and efficient Heat exchange coil performing as designed. - A coil or Surface area prepared and ready for the application of AerisGuard Corrosion Protection Treatment which provides 12-month protection against any further corrosion of the coated surface. This ensures long-term efficiency, optimal system performance and operation as well as maximised operational efficiency. This IFU covers the steps and actions that need to be taken in the use of AerisGuard Outdoor Coil Cleaner (Preparation) products. This IFU meets the requirements of AS/NZS ISO 9001: 2008 standards. All Aeris Environmental personnel, sub-contractors and certified applicators are expected to take an active role in establishing, implementing and maintaining this Procedure in line with this IFU according to their role and responsibility. The purpose of acting in accordance with this IFU is to have an uninterrupted, smooth process that ensures that correct process and use of the products are followed. This IFU shall also be part of Aeris s continuous improvement initiative. by: M. Kritzler Page 1 of 6

2. PROCEDURE DESCRIPTION AND PROCESS FLOW The Clean & Preparation procedure is conducted by a Certified AerisGuard Applicator in accordance with Aeris Environmental Recommendation and your work order and/or job specification. This Process is followed by the application of AerisGuard Corrosion Protection Treatment as outlined in IFU 006 Application of Corrosion Protection Products. The steps in this procedure are as follows: 1. Preparation a. Product Handling & Packaging b. Apparatus & Equipment Required c. Product Dilution and Application Rates d. PPE & OHS Requirements 2. Setup 3. Coil Clean / Preparation Process 4. Cleanup Process 5. End of IFU 3. PROCEDURE 1. Preparation a. Product Handling & Packaging Applicators should consult the product Safety Data Sheet (SDS) prior to use and handling. AerisGuard Outdoor Coil Cleaner / Preparation is ready to use. This product is available in 1L units. The product has a shelf life of 3 years from the date of manufacture. Always store the product out of direct sunlight and not exposed to hot environments for extended periods of time. b. Apparatus & Equipment Required Wet & Dry Vacuum Water pressure washer Aeris Product applicator (4l pump spray with adjustable nozzle / use of larger applicator for large coils) Tarpaulin/Plastic Sheeting Occy-straps Residual Current Device (RCD) Ladder G-clamps Power leads Safety Over-ride Switch Thin rope Extra hose and fittings Broom, Mop and Bucket by: M. Kritzler Page 2 of 6

c. Product Dilution and Application Rates The AerisGuard Outdoor Coil Cleaner / Preparation is supplied READY TO USE and DOES NOT require dilution prior to application. The application rate of the Cleaning / preparation solution is - COIL - 350ml per/m² of Coil face (based on 12 fins/inch and 100mm depth) FLAT METALLIC SURFACE - 200ml per/m² d. PPE & OHS Requirements - Gloves (hi density rubber are recommended) - full or half face masks with filters rated for pesticides and solvents, (P2) - safety goggles (Wraparound Clear are recommended) - full body waterproof suit with hood (Disposable suit is recommended to keep clean) - type 1 heavy duty safety boots should always be worn. Note* Other safety equipment may be required. OH&S requirements can vary geographically or by project nature. 2. Setup a. Ensure that the unit is off line / isolated from operation Prior to and during the entire cleaning (coil preparation) process. This must be done by an appropriately certified person and may require arrangement with the engineering staff at the site if necessary. b. Ensure that equipment being used is protected by a (RCD) Residual Current Device to protect the user from electrical shock. c. Ensure Equipment being used is in good working order. d. Remove filtration media to protect the air filters from any deposits of cleaned contaminants, cleaning solution, treatment solution or water. A tarpaulin or plastic sheeting may be used to cover these if required. Note: Air filters are best disposed of and replaced when decontaminating the air handling system to avoid contamination of the components cleaned downstream of the filters. e. Other parts of the system may need to be covered as well, e.g. fan motor and sensors located near the area to be cleaned. f. Ensure that the hoses for the pressure cleaner are all attached securely to avoid any excess water. g. A Wet Vac should always be set up and ready to be used on all applications. by: M. Kritzler Page 3 of 6

3. Coil Clean / prepare process a. Remove visible contamination - The entire area around the coils and surface area of the HVAC systems must be physically brushed to remove any debris or existing coats which have been dislodged. this process is very important to maximize cleaning / preparation results. Ensures correct surface prep application of corrosion protection products. save overall clean up time at the end of the job. shows a higher level of professionalism. a dust mask must be used on starting the pre-clean. b. Application of AerisGuard Outdoor Coil Cleaner (Preparation) 1. ensure drain lines are not fouled. This can be achieved by flushing the drain lines first. All personal safety equipment must be worn for the remainder of the procedure. 2. Apply Outdoor Coil Cleaner / Preparation solution - To apply the cleaning solution: 1l spray bottle spray directly on to Coil or surface to be cleaned / prepared 5L Bulk decant into 4L Aeris Pump spray applicator and spray directly on to the coil / surface to be prepared - On A Coil It is important to use a jet setting on the tip to maximize penetration and minimise aerosols of the solution. Apply Outdoor Coil Cleaner (Prep) starting from the top of the coil, covering the entire surface of the coil paying special attention to any dirty areas. Wherever possible access and apply Cleaner (Preparation) TO BOTH SIDES of the coil as recommended to ensure best results. - On a flat surface It is important to use an even mist application to ensure that you do not use too much product. - Leave AerisGuard Outdoor Coil Cleaner (Prep.) in contact for at least 15 20 minutes depending on the level of contamination. by: M. Kritzler Page 4 of 6

c. Rinsing / Pressure Clean - After AerisGuard Outdoor Coil Cleaner (Preparation) has penetrated the coil contamination (been allowed to activate for up to 20 mins), the pressure cleaner is used to remove all the dissolved contaminant. - It is important to understand that pressure cleaning coils may increase airborne Macromolecular Organic Dust (MOD) concentrations. Extreme care must be taken to ensure containment to the area being cleaned and treated. Blanking duct entries etc. with sealed plastic sheeting will provide an effective barrier. This also ensures no moisture carry over into supply or return air duct insulation/attenuator. - Pay particular attention to coil fins to avoid any damage such as folding. - The following should be performed on both sides of the coil. The pressure cleaner (if applicable) should be set at higher 45 C for direct expansion refrigerant coils or no higher than 100 C for chilled and hot water coils, Hold the rinsing apparatus at angle of 45 diagonally down the coil and should be kept at this angle while cleaning the face of the coils a. This allows contaminants to be pushed down the coil and into the drain rather than be pushed into the middle of the coil. Each coil should be cleaned from right to left and left to right so as the inner edge of the fin surface is cleaned. This should continue until all foaming has stopped. - For Flat surface Preparation the use or a pressure washer may not be required, ensure that the product has had up to 20 mins activation time rinse with water ensuring that all traces of product have been flushed from the surface. by: M. Kritzler Page 5 of 6

4. Clean up - Ensure that all equipment is cleaned, packed up and removed from the area. - Mop up all excess water and ensure work area is clean and tidy with no sign of being there / Take care to remove plastic sheeting sealing ductwork. Leave the worksite as you found it. - Remove and dispose of all empty product containers. - Remove all rubbish you have taken on site. Recommended additional process It is highly recommended & necessary for warranty that the cleaned and prepared coil or surface be treated with AerisGuard Corrosion Protection Treatment. As described in IFU 006 Application of Corrosion Protection Treatment, this product provides long term benefits: - Prevention from surface corrosion - Sustained and long-term coil efficiency - Improved machine operational performance - 12 month protection from corrosion - Extended asset life by: M. Kritzler Page 6 of 6