DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Similar documents
LS 1 Empty Belt Detector RF Admittance PXL1-XX02 PNL1-A. LS 2 Plugged Chute Detector RF Admittance PXL1-XX50 PNL1-A LS 3

Level Measurement Continuous level measurement Ultrasonic transmitters

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Level Measurement Continuous level measurement - Ultrasonic transmitters

Installation and Operating Instructions

Continuous level measurement Ultrasonic transmitters

RF Admittance Technology FACTS

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

Quick Start Guide For the

PRODUCT CONFORMITY CERTIFICATE

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Ultrasonic Switches. Features & Benefits

Dräger Polytron 8000 Stationary gas detector (EC)

Two-Channel Gas Controller

Model D12-IR. Digital Gas Transmitter...

Rosemount 3100 Series Ultrasonic Level Transmitters

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

AS950 REFRIGERATED SAMPLERS

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Rosemount 3100 Series Ultrasonic Level Transmitters

Dräger PointGard 2100 Detection of toxic gases and vapours

AS950 PORTABLE SAMPLERS

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Model Q45P/R. ph/orp Monitor...

Oxygen (O2) Single-Point Gas Detection System

Model Q45P/R. ph/orp Monitor...

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8310 Stationary gas detector (DSIR)

A New Standard of Excellence

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

Series A3 and A4 Differential Pressure Controller

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Accuracy by Design Products for the HVAC Professional

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Process Alarm Module RTA 421

Clamp-on ultrasonic flow and energy meters for liquids

SPA 2 IS. IECEx. Programmable Limit Alarm Trips with Intrinsically-Safe Field Connections

Rosemount 3490 Series

Dräger Polytron 7000 Fixed gas detector

Ultrasonic Point Level Switches

Dräger Polytron 8700 IR Detection of flammable gases and vapors

T500 Elite - Hotbus Plant Wide Monitoring System for Bucket Elevators & Conveyors

Continuous and Point Level Measurement. Radiometric Sensors for Liquid and Solid Level Measurement

GAS PLUS ALARM SYSTEM

Non-Contacting Point Level Detection and Pump Control Sensor. Setting a New World Standard

WASTEWATER Online UV%Transmission Analyzer

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

Dräger Polytron 5720 IR Toxic Gas Detection

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

for Drinking Water Systems

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Multiview Monitor / Controller

DTM Distributed Transmitter-Monitor

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Dräger Polytron 5720 IR Detection of carbon dioxide

S5000 Gas Monitor. GMS5000.com

Technologies, Solutions, and Applications. Radiation-based Level

MODEL 4100-OWS. Oil/Water Separator Level Monitor. User Manual

LC1350 Level Controller

Model 144H. Product Data Sheet , Rev DB February Content

MODEL 4100-LEV. Level Monitor. User Manual

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

Dräger Polytron 8000 Stationary gas detector (EC)

Flame Monitors BROCHURE

Dust Alert 75. *shown with optional external keypad and display

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Mobrey MCU900 Series Universal Control Unit

Analog Room Pressure Monitor RPC Series

/8 DIN Level Indicator

Dräger Polytron 7000 Detection of toxic gases and oxygen

Programmable Output Dual Relay Quad Relay. (Trip Points, High Alarm, Low Alarm, Failsafe, Non-Failsafe, Normally Open, Normally Closed)

Temperature Controllers

Clamp-on ultrasonic flow and energy meters for liquids

Dräger Polytron 5100 EC Detection of toxic gases and vapors

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

multiranger 100 / 200

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Product Guide LEVEL MEASUREMENT PRESSURE MEASUREMENT TEMPERATURE MEASUREMENT FACTORY AUTOMATION

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Dew-Point Transmitters and Instruments

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Electronic Flow Switches

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH

Electronic Pressure Digest. Pressure and Temperature Transmitters

Nuclear Density Gauges

Instrumentation and Controls Group

Transcription:

DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters via the display with environmentally sealed keypad. The display is menu driven and can easily be configured without detailed procedures: no cryptic codes, no problems. 2-Channel USonic-R can be used in a variety of Level and Open Channel Flow applications. Level Distance Open Channel Flow rate Totalization Pump Alternation - up to 6 pumps Differential Level (Bar Screen) Submerged Flow 4-20mA Signal Outputs w/ Modbus RTU 6 SPDT relays for control or alarm Programmable Batch Sampler Activation Data Logger - 1 to 24 Month Easy Set-Up Via Menu driven configuration via local display with environmentally sealed keypad The USonic-R Continuous Ultrasonic Level Series is a versatile package available with analog outputs, and 6 SPDT relays. This multifunctional system can be used in a wide variety of applications ranging from simple indication of level as well as open channel flow rate and totalization to more demanding two channel inputs such as differential level and submerged flow. When relay outputs are required, (6) SPDT relays rated at 5A @ 250VAC allows additional features such as alarm or control functions plus Batch Sample Activation and Pump Alternation of up to 6 pumps. The USonic-R continuous ultrasonic level system features a full, 7-digit, Back-Lit, LCD, display. The large display can be viewed easily from a distance or when process lighting conditions are dim. The USonic-R is preprogrammed with common tank shapes and Open Channel Flume and Weir characterizations. The menu driven software additionally offers a 21-point strapping table for non-linear inputs in level, volume or open channel flumes and weirs.

SmartGain Eliminates interfering signal reflections from agitators and other internal vessel obstructions without the need to empty the vessel and without operator intervention. Easily ignores pipes and similar obstructions that may be within the sonic beam path. Automatically ignores diffi cult internal obstructions No user adjustments required Full Tank Measurement Transducer can be recessed in a 2-inch or larger ID nozzle to allow level measurements to the very top of the vessel. Bench Configuration Eliminates the need to move process material levels for confi guration 2-Inch Nozzle Mounting Compact transducer design allows mounting in any 2-inch nozzle. It also allows for a recessed nozzle mounting enabling level to be read to the very top of the vessel. Ideal for Hazardous Area Installations Units designed for installations in Class 1 Div. 2, Zone 2 environments with sensors designed for Class I Div. 1, Zone 0, Zone 1. Easy View Display 1 x 4 Backlit LCD display, wall mount. 2-line display, top line - 10 characters 9.8 mm tall, second line - 7 characters 15.5 mm tall Software Options Level, distance in: %, inches, feet, mm, cm, m Flow rate in: GPM, M3/Hr. (2) Totalizers, (1) resettable, and (1) non-resettable. Differential level Traveling Bar Screen, Submerged fl ow. Pump Alternation up to 6 pumps. Batch Sample Activation based on totalized fl ow with dry relay contact closure with adjustable pulse durations. Characterizations of common fl umes and weirs plus customer confi guration of nonstandard fl umes and weirs via a 21-point strapping table. Supported Flume & Weir Characterizations: Parshall Rectangular (With & Without end contractions), Trapezoidal (Cippoletti) Weir Trapezoidal Flume V-Notch Weir Leopold-Lagco Palmer-Bowlus Compound Weir H Flume.

Ignore difficult internal obstructions with patented SmartGain SmartGain is a standard feature with every system and prevents unwanted reflections from internal obstructions and agitator blades. SmartGain automatically controls the transmitter gain (sensitivity to returned echoes). Without user intervention, the USonic-R ignores obstructions that are mounted within the sonic beam path. SmartGain also provides measurement advantages in horizontal cylinders and spheres by reducing the effects of multiple reflection signal paths. 2" dia. nozzle Ignore a 2-Inch (50 mm) Pipe The edge of a 2-inch (50 mm) pipe can be as close as ½ inch (12 mm) from the centerline of the transducer, and ignored. Pipe Obstruction in Beam Path Ignore a 1-Inch (25 mm) Pipe The edge of a 1-inch (25 mm) pipe can be 1-inch (25 mm) from the centerline of the transducer, and ignored. 10 Quick Start-Up: 1. Choose Level or Flow as an input type. 2. Choose Configuration Units (Feet, Inches, Meters, Centimeters, Millimeters). 3. Enter Tank Height. 4. Enter LRV (4 ma point) and URV (20 ma point). That s all that is needed to start measuring Level! Easy user-defined configuration as simple or complex as needed. In addition to a quick and easy start-up, in-depth configuration allows the conversion of Level to Volume through internal strapping tables or open channel flow tables and totalizer settings. The USonic-R has (2) 7-digit totalizers per channel for use in flow measurement inputs; one totalizer per channel is resettable. Systems settings allow user-defined system gain, repetition rates, time delay, error signals, display options, diagnostics and more.

Specifications Input Power 120 VAC & 24 VDC 240 VAC & 24 VDC Output signal options (2) Active 4-20mA with Modbus RTU Maximum Loop Resistance 1000 ohms Output Mode Level, Distance, Flow, Volume Display Indications Level, Distance, Flow Rate, Volume, Totalization, Temperature, Signal Strength, Milliamp. User selectable, multiple selections can be scrolled automatically. Range 1 to 30 ft. (0.3 to 9.1m). Near Zone 12 inches (305 mm). Minimum span 3 inches (76 mm). Maximum Span 30 ft. (9.1 m). Display 2-line, backlit LCD, UV protected. Top line, 10 characters 9.8 mm tall. Second line, 7 characters 15.5 mm tall. Accuracy +/- 0.15% or 0.2 inch (5 mm) of sensor range, which ever is greater. Repeatability < 0.12 inch (3 mm) Resolution < 0.12 inch (3 mm) Response Time Less than 1 second Ambient Temperature Limits -40 F to 158 (-40 C to 70 C). Data Logger - 1 to 24 Month Maximum time period dependant on sample rate Optional RS232 to DB9 cable (#380-5000-100) is required to download Datalogger to PC. 16 ft. (5 m) Temperature Compensation Built-in, Automatic and readable from display. Fail-Safe 3.7 and 22 ma error signals user selectable for Lost Echo and Near Zone violations. Configuration Local Display with Keypad, password protected Signal Damping User programmable from 0 99 seconds. Relays: (6) SPDT @ 5A 250VAC with 10 user defined trip points. SmartGain Standard feature on every system Sensor 6 CPVC, rated -40 F to +158 F at 50 psig. (-40 C to +70 C at 3.4 bar) Remote Sensor Cable Length Max. cable length to 1200 ft. (365 m) Max. cable length factory supplied, 300 ft. (91 m) Sensing element connection 2-inch & ¾ NPT/BSP fitting, CPVC Flange mounting (via threaded flanges) Frequency 50KHz Beam Angle Conical, 10 @ 3db down Enclosures Electronics: Fiberglass reinforced Polyester (FRP) to NEMA 4X (IP-66) Sensor: CPVC rated NEMA 6 (IP-67) Approvals Electronics: Class I, Div. 2, Zone 2 hazardous locations. Sensors: Class I, Div. 1, Zone 0, Zone 1 FM, CSA, CE, ATEX, Test Safe, Cepel, GOST - pending * Specifications subject to change without notice

Model Numbering USonic-R Technology USonic-R Power Continuous Line-Powered Ultrasonic Level Measurement System 1 120 VAC, 24 VDC 2 240 VAC, 24 VDC Output 1 Analog 4-20 ma outputs with Modbus 2 Analog 4-20 ma outputs with Ethernet (consult factory) Approvals 1 FM, CSA, Test Safe, Cepel, GOST - Class 1, Div. 2 - (Pending) 2 ATEX, CE - Zone 2 - (Pending) Sensors 0 Without 1 One Sensor 3/4" / 2" NPT 2 Two Sensors 3/4" / 2" NPT 3 One Sensor 3/4" / 2" BSP (G) 4 Two Sensors 3/4" / 2" BSP (G) Sensor #1 Cable length 0000 Without 0025 25 Ft. Continuous Run - Standard 0050 50 Ft. Continuous Run 0100 100 Ft. Continuous Run 0150 150 Ft. Continuous Run 0200 200 Ft. Continuous Run 0300 300 Ft. Continuous Run Sensor #2 Cable length 0000 Without 0025 25 Ft. Continuous Run - Standard 0050 50 Ft. Continuous Run 0100 100 Ft. Continuous Run 0150 150 Ft. Continuous Run 0200 200 Ft. Continuous Run 0300 300 Ft. Continuous Run USR * Model Number subject to change without notice Accessories: Optional RS232 to DB9 cable 16 ft. (5 m) is required to download Datalogger to PC. (Part #380-5000-100)

Other Great Solutions By: DREXELBROOK NEW! U.S.A. Sales: 800-553-9092 24-Hour Service: 800-527-6297 International Support: 215-674-1234 Fax: 215-674-2731 AMETEK Nihon Drexelbrook AMETEK Singapore Pte. Ltd. AMETEK Precision Instruments Europe 2 Chome 12-7 Minami Gyotoku 10 Ang Mo Kio Street 65 Rudolf-Diesel-Strasse 16 DREXELBROOK Ichikawa City Chiba 27201 Japan #05-12 Techpoint 569059 Singapore D-40670 Meerbusch Germany Phone: 81-473-56-6513 Phone: 65-6484-2388 Phone: 49-2159-9136-0 Fax: 81-473-56-6535 Fax: 65-6481-6588 Fax: 49-2159-9136-39 205 Keith Valley Road E-mail: nd@nihon-drexelbrook.co.jp E-mail: aspl@ametek.com.sg Web: www.ametek.de Horsham PA 19044 U.S.A. E-mail - drexelbrook.info@ametek.com Web - www.drexelbrook.com 2005, by AMETEK, Inc. All rights reserved. Printed in the U.S.A. USR-XX-A EDO# 10-05-248 Issue# 4