Tools Required Small, flat-head screwdriver Phillips screwdriver (for mounting hardware) Wire stripper and cutter

Similar documents
Uponor Climate Cŏntrol Network System Thermostat Installation and Operation Guide RADIANT HEATING SYSTEMS UPONOR CLIMATE SYSTEM THERMOSTAT

Climate Cŏntrol Multifunction Hydronic Control Installation and Operation Manual. Uponor Radiant Heating and Cooling Systems

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Digital Non-Programmable

Thermostats. Digital Non-Programmable. GEAppliances.com. Owner s Manual & Installation Instructions RAK148D2 RAK164D2

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

ADC-T2000. Smart Thermostat v1.5

SC Installation, Operation & Application Guide

Install Guide 8046 ENGLISH. Customer Support: or: visit our website Printed in China ON.

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

T8401C Electronic Thermostats

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

Install Guide Customer Support: or Visit our website

Radiant Thermostat 519

Smart Temp. Model

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

SC Installation, Operation & Application Guide

SC Installation, Operation & Application Guide

Thermostats. Digital Programmable. GEAppliances.com

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

Heat Link. Technical Guide

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

T500 Series Non-Programmable Thermostats

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT!

T6984F,G Electronic Floating Control Thermostats

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

propanel Series Installation Manual

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

Smart Temp. ApolloP/n Installation Manual. Version 1.0

SC Installation, Operation & Application Guide

T874 Multistage Thermostat and Q674 Subbase

Owner s Manual. Digital Thermostat

SC Installation, Operation & Application Guide

Comfort System T-21-P Touchscreen Thermostat Installation Manual

ATP21W02 CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS REMOVING OLD THERMOSTAT 2 THERMOSTAT DETAILS

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

T8411R Electronic Heat Pump Thermostat

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

1F60-22 INSTALLATION & OPERATING MANUAL SETBACK THERMOSTAT. Homeowner: Save this booklet for future use!

Model NT20e Installation Guide

Owner s Manual. 5+2 Day Programmable Digital Thermostat

Operator: Save these instructions for future use!

SC Installation, Operation & Application Guide

ETN24-P/PD-FC-SUPER2. Owner's Manual - Installation and Operating Instructions

T8011R Programmable Heat Pump Thermostat

Installation Instructions

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

CT500 Electronic Thermostat

T4398A,B Precision Electric Heating Thermostat

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

RS332N BUTTON OPERATION INTRODUCTION. Installation and Operation Instructions for REMOVING THE THERMOSTAT FROM THE BACKPLATE

TH146-N-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

- Essay Control Functions and Benefits

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Operator: Save these instructions for future use!

T-32-TS Touchscreen Thermostat. Installation Manual

IMPORTANT INSTRUCTIONS FOR FAN-FORCED HEATER USE

tcu.z Commercial Programmable Thermostat Installation Instructions

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

ELECTRONIC COMMUNICATING THERMOSTAT

PROGRAMMABLE THERMOSTAT

Programmable Thermostat

Net/X US32 Universal Setback Communicating Thermostat

Thermostat Installation Best Practices

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

Install Guide CT100. Caution. Caution

552_U 09/14. tekmarnet Thermostat 552 Zoning Replaces: 08/11. User Manual. 1 of 12. A Watts Water Technologies Company _U - 09/14

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3011C Non-Programmable Thermostat. Table of Contents. L3011C Thermostat

- Data Brochure Mixing Control 360

5+2 Day. up to HEAT COOL

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7

MR3CCUHV Temperature/Defrost Control

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

7-Day. Digital Thermostat. residential. & 2-cool

Line Voltage Non- Programmable Thermostat Installation Instructions & User Guide

Installation & Operation Manual

7-DAY or 5/2-DAY PROGRAMMABLE, OR NON-PROGRAMMABLE THERMOSTAT INSTALLATION AND OPERATING INSTRUCTIONS

Networkable Fan Coil Controller Specification and Installation Instructions

Analog Room Pressure Monitor RPC Series

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

INSTALLATION/OPERATING INSTRUCTIONS BCP-3. Hot Water Reset Control For up to 3 Boilers. How the BCP-3 operates... 1:4 1:3 1:2 1:1.

TEC1100 Series Thermostats

Installation Instructions

Operator: Save these instructions for future use!

Safety & Installation Instructions

WSK300 Multifunction Wall Control

Operator: Save these instructions for future use

Daikin ENVi Thermostat installation overview

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Wireless Rain Gauge with Indoor Temperature

PerFormance Pro t4900 school series InstallatIon GUIDe

Transcription:

RADIANT HEATING SYSTEMS HEAT AND COOL THERMOSTAT INSTRUCTION SHEET Technical Data Operating Voltage 24VAC +/- 10% Maximum Load 1.3 Amps at 24VAC 4 x MVA (part number A3020522) 6 x TVA (part number A3010522) Display Range 38 F to 99 F (2 C to 37 C) Setting Range 38 F to 99 F (2 C to 37 C) 68 F (20 C) heating default 75 F (24 C) cooling default Minimum Limit 38 F (2 C) to maximum limit 50 F (10 C) default minimum Maximum Limit Minimum limit to 99 F (37 C) 86 F (30 C) default maximum Units User-configurable Fahrenheit or Celsius Memory Permanent s and mode without power Freeze Protection Activation at 38 F (3.3 C) De-activation at 39 F (3.8 C) Overheat Activation at 100.4 F (38 C) Protection De-activation at 98.6 F (37 C) Resolution 1 displayed 0.25 calculated Temperature Shipping and storage: 14 F to Ranges 158 F, (-10 C to 70 C) Operation: 32 F to 104 F, (0 C to 40 C) Humidity 20 to 90% non-condensing Size 5" H x 2.72" W x 0.91" D Overview The Uponor Heat and Cool Thermostat (A3030102) controls hydronic heating, air conditioning and a fan. The six-wire thermostat receives power from the Rh (radiant heating) and C (cooling) terminals. These thermostats are powersharing, meaning they receive power for operation by sharing voltage with the connected wiring. This eliminates any need for a third wire or batteries, making them simple to install, wire and service. Note: Uponor thermostats work effortlessly with other Uponor components. However, some commonly used third-party devices (e.g., relays, zone valves, etc.) may have compatibility issues with these thermostats. If connecting the Uponor thermostat to a third-party control device, refer to that device s installation instructions for specific information regarding operation with power-sharing thermostats. The Typical Wiring Schematics section on page 5 features the most common wiring applications. For additional help, contact Technical Services. Uponor U.S.: (800) 321-4739 Uponor Canada: (888) 994-7726 Tools Required Small, flat-head screwdriver Phillips screwdriver (for mounting hardware) Wire stripper and cutter Installation To properly install the thermostat, 1. Thoroughly read this instruction sheet to understand the proper procedures for installation and operation. Failure to do so could result in damage to the thermostat or its connected equipment, and can also create a safety hazard. 2. Ensure the function and rating of the thermostat is suitable for the application. 3. Only experienced and trained professionals familiar with lowvoltage wiring should attempt to install the thermostat. 4. Uponor recommends using 18AWG LVT wiring for all low-voltage connections (as regulated by local building codes). Placing the Thermostat Thermostat placement is extremely important. Install the thermostat approximately five feet (1.75 meters) above the floor on a smooth, flat surface. Avoid mounting the thermostat in the following locations. Near or around windows On outside walls Near fireplaces In the corner of a room Behind doors On interior walls susceptible to solar gains Near stoves, lamps, televisions, etc. Damp areas

Mounting the Wall Plate The thermostat case can mount to a standard electrical wall box or most wall surfaces using suitable hardware. To properly mount the wall plate, refer to the following instructions. 1. Separate the front and back plates of the thermostat by gently applying downward pressure on the front plate to separate the front plate from the back plate. 2. Pull the thermostat wire through the round opening in the back plate. 3. Place the back plate against the wall at the desired location to cover the opening or electrical wall box. 4. Align the holes of the back plate to the holes in the wall or electrical wall box, and attach the plate with screws. If mounting the plate to drywall, use wall anchors and screws. 5. If the wall cavity behind the thermostat is susceptible to drafts (e.g., from a return-air plenum or an uninsulated wall), plug and seal any openings to prevent them from affecting temperature readings. Wiring the Thermostat Push top down to separate To properly wire the thermostat, Note: All wiring must comply with local electrical codes and standards. Caution: Disconnect electrical power to the system to prevent electrical shock and damage. 1. Remove 1 4" of wire insulation from the wire ends. Ensure the bare wires are clean and free of corrosion. 2. Route the wires to the terminal blocks and place the end of the wires in the correct wiring locations. Note: The heat terminals (Rh and W) are not polarity sensitive. Mounting the Thermostat to the Wall Plate To mount the thermostat to the wall plate, refer to the following instructions. 5.00" (127mm) 2.72" (69mm) 18 AWG, 2 Cond. Stranded 1. Place the tabs at the bottom of the front enclosure into the grooves at the back of the wall plate. 2. Check the alignment between the two components. 3. Apply pressure to the top of the thermostat until it snaps into place. Operation The dynamics of a radiant heating system differ from a typical baseboard or forced-air heating system. This is because radiant systems heat the mass and the objects in the room. The Uponor thermostat uses optimized control logic to control radiant systems. Refer to the following information for the different modes of operation. 2.5" (63.5mm) 0.75" (19mm) Heating Mode When the room temperature falls 0.5 F (0.25 C) below the desired room, the control devices wired to the thermostat activate. When the room temperature rises 0.5 F (0.25 C) above the desired room, the control devices wired to the thermostat deactivate. Cooling Mode When the room temperature rises to 1 F (0.5 C) above the desired room, the control devices wired to the thermostat activate. When the room temperature falls 1 F (0.5 C) below the desired room, the control devices wired to the thermostat deactivate. Automatic Mode The thermostat automatically switches between heating and cooling modes based on the heating and cooling setpoints. (The cooling setpoint must be greater than or equal to the heating setpoint.) When the thermostat is in automatic mode, the cooling mode icon (snowflake) flashes when the cooling system is active; the heating mode icon (floor with tubing) flashes when the heating system is active. Pulse Width Modulation (PWM) Mode When the room temperature is between 1 to 3 F (0.5 to 1.5 C) below the desired room, the thermostat manages the application of heat by varying the on-and-off cycles, or what is known as pulse width modulation (PWM). The on-and-off times vary depending on the difference between room and desired temperatures the further away, the greater the on time. This prevents the room temperature from rising above the desired temperature. The heating system will run continuously at temperature differences greater than 3 F (1.5 C). 2

Note: In PWM mode, the heating equipment may temporarily turn off even when the heating icon is flashing (indicating a call for heat). Note: Operating forced-air heat disables PWM mode. Refer to the Differential Setting section on page 4 for further details. Digital Filtering The thermostats also feature digital filtering, meaning the thermostat continuously measures the room temperature and employs a digital filter to create a stable reading and consistent operation. If each room temperature reading displayed as it is sensed, the temperature shown would appear erratic and inconsistent. The filtering technique throws out sensor readings with large differences from the displayed temperature and then limits the amount any individual reading can affect the overall displayed reading. This results in a smooth display and operation. Note: Due to filtering, the displayed room temperature can take up to a minute to change 1 F (0.5 C). Important: Uponor thermostats conform to universal industry standards. Uponor is not responsible for damages resulting from misapplication or misuse of its products. To avoid damage to the thermostat, install the thermostat with the power disconnected. Setting and Adjusting the Thermostat All user functions operate via two buttons (+ and ) located on the front of the thermostat case. Power Up and Power Interruption After completing all electrical connections and properly mounting the thermostat, apply power to the system. The thermostat reading automatically starts at 68 F (20 C) in heating mode, which is the default temperature and mode. The Uponor thermostat can recall the previous temperature and mode if power is interrupted. When power is restored, the thermostat s reading will start at the previous temperature and the previous mode (Heat, Cool or Off). Normal Operation The thermostat displays the current room temperature measured by the thermostat along with the mode of operation. The following icons indicate the mode of operation. None Thermostat is turned off. Floor with tubing Heating mode is active with no call for heat. Floor with tubing and lines flashing above Heating mode is active with a call for heat. Snowflake Cooling mode is active with no call for cooling. Flashing snowflake Cooling mode is active with a call for cooling. Snowflake and radiant panel Automatic mode is active. Fan The fan is on. Adjusting the Temperature To adjust the temperature, Pressing the + (increase or top button) or (decrease or bottom button) changes the desired room temperature. 1. Press either button to enter the program mode. 2. When adjusting the heating setpoint, the Heating icon will flash; when adjusting the cooling setpoint, the Cooling icon will flash. 3. Press the + (top button) to increase the room and the (bottom button) to decrease the room. Press and hold the button to rapidly change the temperature. new five seconds after pressing the last button; then the thermostat reverts to displaying the current room temperature. Note: When the mode is set to Off, temperature s cannot be changed or adjusted. Note: If the thermostat is in Automatic mode, changing the will change the setpoint that is currently active. When the thermostat is set for Automatic mode, and Cooling mode is active, changing the will affect the cooling setpoint. When the thermostat is set for Automatic mode, and Heating mode is active, changing the will affect the heating setpoint. The mode icon will flash to indicate which mode is active when changing the setpoint in Automatic mode. To change a setpoint, that mode must be active (e.g., if the Cooling mode is active and the user wants to change the heating setpoint, the user must activate the Heating mode to change the heating setpoint). Changing Modes (Heating, Cooling and Off) This thermostat does not use a switch to change the mode from Heat to Off. To change the modes, 1. Press both (+ and ) buttons simultaneously to change the mode. 2. Ensure the program bar is flashing to indicate the thermostat is in the programming mode. 3. Press the + or button to change the mode of operation. Using the + (top) button or the (bottom) button changes the rotation sequence of the icons or modes. 3

The following icons indicate the mode. None Thermostat is off Floor icon Heating mode with automatic fan Floor and fan icons Heating mode with fan turned on Snowflake icon Cooling mode with automatic fan Snowflake and fan icons Cooling mode with fan turned on Snowflake and floor icons Automatic mode with automatic fan Snowflake, floor and fan icons Automatic mode with fan turned on Fan icon Fan operates, but heating and cooling devices will not activate Note: The thermostat accepts changes five seconds after Important: The thermostat remembers the previous operating mode and s after it is powered off. Advanced Settings The Uponor thermostat features extra s, which are accessed via the Special Setting button on the inside of the thermostat case. When using this button, the thermostat must be wired and have power, but needs to be separate from the wall mounting plate. Note: Uponor recommends only qualified installers change these s. Improper adjustment of these s can result in damage to the thermostat. Units The Uponor thermostat is capable of operating in either Fahrenheit or Celsius. To change the units, 1. Press the Special Setting button once. 2. The display shows the units icon ( F or C). button to change the units. Upper Setting Limit To set the upper limit of the allowable temperature range, 1. Press the Special Setting button twice. 2. The number 1 will appear in the lower left of the display along with the temperature. button to increase or decrease the upper limit of the thermostat. Lower Setting Limit To set the lower limit of the allowable temperature range, 1. Press the Special Setting button three times. 2. The number 2 will appear in the lower left of the display along with the temperature. button to increase or decrease the lower limit of the thermostat. Note: Use the upper and lower limit for public thermostat operation. By these limits to the same value, a user cannot change the thermostat. Sensor Reading Calibration This varies the reading of the thermostat to overcome installation-related issues. 1. Press the Special Setting button and the + (top) button at the same time. 2. The display shows a single digit number and the set operating units. button to increase or decrease the sensor reading offset. Positive numbers increase the sensor reading; negative numbers decrease the sensor reading. Important: Adjust the sensor reading calibration as a last resort after first trying all other remedies. Differential Setting This allows the user to select a straight 2 F differential when operating a furnace or air handler, or the standard Uponor heat algorithm for radiant floor heating as described in the PWM Mode section on page 2. 1. Press the Special Setting button and the (bottom) button at the same time. 2. The display indicates either AH (air handler/furnace) or FL (floor heating). button to change the as required. 4. The thermostat accepts the change five seconds after pressing the last button and then returns to Important: Uponor recommends using the FL or floor heating with radiant heating systems. 4

Freeze Protection The thermostat features automatic low-temperature protection to prevent freezing. Regardless of the temperature and mode (Heating, Cooling or Off), the thermostat will activate the heating circuit at 38 F (3.3 C) until the room temperature reaches 38.8 F (3.8 C). Users cannot disable this feature. Overheat Protection The thermostat features an automatic high-temperature protection to prevent overheating. Regardless of the temperature and mode (Heating, Cooling or Off), the thermostat will activate the fan and cooling circuits at 104 F (38 C) until the room temperature reaches 98.6 F (37 C). Users cannot disable this feature. Typical Wiring Schematics Figure 1: Typical Wiring for a Zone Control Module for Heating Only Figure 2: Typical Wiring for Heating and Cooling Figure 3: Typical Wiring Using Cooling Only 5

UHAC_Thermostat_IS_USACA_11-06, Copyright 2006 Uponor, Printed in the United States Uponor, Inc. 5925 148th Street West Apple Valley, MN 55124 Tel: (800) 321-4739 Fax: (952) 891-1409 Web: www.uponor-usa.com E-mail: learnmore@uponor-usa.com Uponor Ltd. 655 Park Street Regina, SK S4N 5N1 Tel: (888) 994-7726 Fax: (800) 638-9517 Web: www.uponor.ca E-mail: info@uponor.ca