Water-cooled Thermo-chiller

Similar documents
Water-cooled Thermo-chiller

SEMI Standard S2-0703, S8-1103, F

Refrigerated Thermo-chiller

Water-cooled Thermo-chiller

Type of Fluorinated fluids / Ethylene glycol aqueous solution / circulating fluid: Clear water, Deionized water Temperature range setting:

Water-cooled Thermo-chiller

0.1 c. R134a (HFC) Thermo-chiller. ( A device for circulating a fluid ) Series HRZ. with a constant temperature

Circulating Fluid Temperature Controller Refrigerated Thermo-cooler

Added cooling capacity of 140 W and 320 W (watercooled), (air-cooled). Thermo-con. controlled to a constant temperature

Added cooling capacity of 140 W. (air-cooled).

Thermoelectric Bath. Series HEB

HEB Series. Peltier-Type Thermoelectric Bath

Can precisely control the temperature of a heat source or process fluid.

Chiller Lineup. Thermo-chiller. A chiller is used to control the temperature of circulating fluid and supply it to the heat source.

Thermoelectric Bath. Series HEB

Mountable in a 19-inch rack

Added cooling capacity of 140 W. (air-cooled).

Refrigerated Thermo-cooler

HEB Series. Thermoelectric Bath

RoHS HRG(C)005 (Existing model) (mm) 69 kg 5100 W

using heat exhausted by refrigerating circuit.

Large energy saving by triple control!

±0.1 C. 40 kg. 47 kg. 69 kg 73 kg. With heating function. Convenient functions

Precisely control the temperature of the circulating fluid by using the Peltier device. Refrigerant-free and environmentally friendly.

Large energy saving by triple control!

A Chiller is equipment to control temperature of customers heating sources. Application Examples

Lightweight and Compact

10 c to 60 c 300 W, 500 W, 750 W. direct temperature control for chemical liquids!! HED Series. Industry-leading withstand pressure 0.35 MPa!!

Large energy saving by triple control!

Peltier-Type Temperature Control System for Chemicals. Fluororesin heat exchanger allows direct temperature control for chemicals!!

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz.

Operation Manual Installation Operation

Operation Manual Installation Operation

Operation Manual Installation Operation

Recirculating Coolers

Refrigerated Air Dryer

Operation Manual Installation Operation

Refrigerated Air Dryer

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

Refrigerated Air Dryer

Refrigerated Air Dryer

Precise Temperature Control; Compact Footprint

Operation Manual Installation Operation

% by up ctoond re-heater and

Refrigeration air dryer

Operation Manual Air-refrigerated Thermo cooler HRG010-A HRG015-A SMC Corporation Save This Manual Carefully for Use at Any Time

Operation Manual Installation Operation

Technical Data C O N T E N T S

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

Two-Channel Gas Controller

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Brazed Plate Heat Exchanger

Brazed Plate Heat Exchanger

Water Circulator (Chiller) & Cold Trap

CHILLER. Operator s & Installation Manual

Compact Ultra Low Temperature Chamber

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

Cool IR. Model C104 - Cooling System. Instruction Manual

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Bench-Top Type Temperature (& Humidity) Chamber

Faster Temperature (& Humidity) Chamber

REFRIGERATION PRODUCTS

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Guide Specifications for InRow Direct Expansion

DOUBLE EFFECT ABSORPTION CHILLERS

Pressure Switches Precautions 1 Be sure to read this before handling.

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

GATEKEEPER GAS PURIFICATION SYSTEM DX SERIES FOR 20, 30, 50 AND 60 NM 3 /HR

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

AS950 REFRIGERATED SAMPLERS

Liquid to Liquid Thermal Shock Chamber TSB 21 TSB 51

Refrigerated Air Dryers

Series Temperature Controller Instruction Sheet

General Specifications

Contour TM Screw Compressors

Thermal Shock Chamber TSE 11

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Refrigerated Air Dryers

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test

GateKeeper Gas Purification System Z2 Series

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

Refrigerated Air Dryers

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

MACH N-407 Heat Pump Air-Cooled Chiller

GateKeeper Gas Purification System SX Series

GateKeeper Gas Purification System Z2 Series

DIESEL Engine Fire Pump Controllers Features

4.Metering Pumps CONSTRUCTIONS. CR-N Series CRA-N Series: servo control model. CRP-N Series

OG5000 Ozone Generator Model OG5000B-A. User Manual

16TJ Single-Effect Steam-Fired Absorption Chillers SUPER ABSORPTION. Nominal cooling capacity kw

Transcription:

Circulating Fluid Temperature Controller Water-cooled Thermo-chiller Series Refrigerant-free and energy saving type using no compressor. Ideal for ordinary temperature and high temperature processes. Type of circulating fluid: Fluorinated fluids/ethylene glycol aqueous solution/clear water, Deionized water Temperature range setting: 68 to 194 F (2 to 9 C) Cooling capacity:2 kw/8 kw/15 kw/ kw Temperature stability: ±.54 F (±.3 C) More effective energy-saving Inverter type through use of an inverter pump Power consumption.5 kwh/h Facility water.32 gpm (1.2 L/min) HRZD HRZ HRS HRG HEB HEC International standards: SEMATECH S2-93, S8-95 SEMI Standard S2-73, S8-113, F47-2 97

Energy-Saving and Refrigerant-free Energy-saving and refrigerant-free (Ordinary temperature up to 194 F (9 C)) The water-cooled Thermo-chiller which does not use a compressor (refrigerant-free) is suitable for processes operating from ordinary temperature to 194 F (9 C). The energy-savings shown below can be achieved in comparison with existing models (depending on the conditions). Power consumption: Max. 59% reduction (SMC comparison) The power consumption can be reduced by direct heat exchange between the circulating fluid and facility water with no refrigerating circuit. Existing model 8-H 1.9 kwh/h 4.6 kwh/h Existing model Facility water circuit Refrigeration circuit circuit Heat exchanger Heat exchanger Compressor Facility water circuit circuit Heat exchanger Operating conditions: 14 F (6 C), kw with 5% load, 8 kw with 5% load Reduced running cost Contribution to the environmental preservation : Max. 13% reduction (SMC comparison) Enhanced temperature control technology and the unique pump/tank construction achieved the reduced circulating fluid required for operation. Existing model 8-H 4 gal (15 L) 3.4 gal (13 L) Comparison of the required circulating fluid inside a Thermo-chiller Reduced initial cost Contribution to the environmental preservation Pump Inverter Type More effective energy-saving is achieved through use of an inverter pump. Power consumption: Max. 89% reduction (SMC comparison) Existing model 8-HS.5 kwh/h 4.6 kwh/h Operating conditions: 14 F (6 C), kw with 5% load, 8 kw with 5% load Facility water: Max. 89% reduction (SMC comparison) The series can achieve reduction in power consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly with the circulating fluid. Existing model 8-H Existing model 8-HS.32 gpm (1.2 L/min) Operating conditions: 14 F (6 C)C, kw with 5% load, 8 kw with 5% load, By-pass valve fully closed Reduced facilities investment Space saved facility water equipment Reduced running cost Facility water: Max. 89% reduction (SMC comparison).32 gpm (1.2 L/min) 3. gpm (11.2 L/min) Operating conditions: 14 F (6 C), kw with 5% load, 8 kw with 5% load, By-pass valve fully closed 3. gpm (11.2 L/min) Space-Saving Thermo-chiller with exhaust from the side Installation area: Max. 45% reduction (SMC comparison) (Forced exhaust from rear side) By emitting the heat from the back, ventilation slits on the side are unnecessary offering reduced installation space. Thermo-chiller with exhaust from the side: Body space: W15.7in (4 mm) x D 33.3 in (845 mm) Ventilation space: 3.9 in (1 mm) 8-H : Body space: W15. in (38 mm) x D 26.2 in (665 mm) Ventilation space: 15. (38) 26.2 (665) 5.5 ft 2 (.51m 2 ) 15.7 (4) 3.9 (1) 1. ft 2 (.93 m 2 ) 33.3 (845) 98

temperature Cooling capacity (kw) 178 F (81. C) 176 F (8. C) 174 F (79. C) 8 kw load kw load 35 25 2 15 1 5 High Performance Temperature stability: ±.54 F (when a load is stable) Enhanced temperature control technology achieved ±.54 F (±.3 C) temperature stabilities when a load is stable. 2 min. 15-H1 Cooling capacity: Max. kw Up to kw cooling capacity achieved. 5 7 9 11 1 15 17 F -H2 Time 1 2 4 5 6 7 8 Temperature difference t ( C) ( temperature Facility water temperature) Easy maintenance Checking the electrical component parts accessible from the front side only Possible to replace the maintenance parts (such as a pump) without removing the pipings and discharging the circulating fluid. Various alarm displays (Refer to page 117.) 1. Normal operation Option Internal pump Easy Maintenance automatic recovery function (Refer to Options on page 119.) inside a Thermo-chiller tank can be recovered automatically. (Recovery volume: 3.2 gal (12 L)) Reduced maintenance time Faster operation Reduced circulating liquid loss by evaporation or spill All you have to do is to push the communication button for recovery and reset! recovery tank Heater Circulating pump Main tank 2. recovery Option Internal pump recovery tank Heater Circulating pump Main tank Non-return valve Non-return valve Option N2 purge port Heat exchanger Option N2 purge port Heat exchanger Existing model Circulating fluid outlet Facility water inlet Facility water outlet return port Circulating fluid outlet Facility water inlet Facility water outlet return port Customer s machine Customer s machine 3. Fluid returns to the main tank from the circulating fluid recovery tank. Option N2 purge port Option Customer s Circulating machine fluid outlet Internal pump recovery tank Heater Main tank Circulating pump Non-return valve Heat exchanger Facility water inlet Facility water outlet return port electrical resistivity control function (Refer to Options on page 118.) (DI control kit) HRG HRS HRZ HRZD HEC HEB 99

Electrical Resistivity Control DI control kit (Refer to Options on page 118.) Electrical resistivity of circulating fluid (ethylene glycol aqueous solution and deionized water) can be controlled. Communications Contact input/output signal Serial RS-485 communication Analog communication (Refer to Options on page 118.) DeviceNet communication (Refer to Options on page 118.) DI filter Construction and Principles Wetted parts adopt the materials compatible for various circulating fluids. (Stainless steel, EPDM, etc.) Fluorinated fluids: Flourinert FC-4 GALDEN HT2 6% ethylene glycol aqueous solution Deionized water/clear water Regarding the fluid other than the above, please contact SMC. Flourinert is a trademark of 3M. GALDEN is a registered trademark of Solvay Solexis, Inc. Level switch Internal Heater pump Temperature fuse Circulating pump Pressure sensor Non-return valve Temperature sensor Temperature sensor Heat exchanger circuit Solenoid valve Flow rate sensor Temperature sensor Facility water circuit outlet Rc3/4 Facility water inlet Rc3/4 recovery tank Circulating fluid fill port Circulating fluid level gauge Temperature sensor Facility water by-pass pipe Facility water outlet Rc3/4 return port Rc3/4 Main tank Leak switch (float type) Tank drain port Rc3/8 Drain pan port Rc3/8 circuit With the circulating pump, circulating fluid will be discharged to the customer s machine side. After the circulating fluid will heat or cool the customer s machine side, it will be returned to the main tank via the heat exchanger. When the automatic circulating fluid recovery function, which recovers the circulating fluid from the customer's machine, is selected (refer to page 99), a sub-tank for recovery is installed. The internal pump is used to transfer a circulating fluid from the sub-tank to the main tank. Facility water circuit When the circulating fluid temperature rises higher than the set temperature, open the solenoid valve to introduce facility water to the heat exchanger. When the circulating fluid temperature falls back below the set temperature, close the solenoid valve to shut off facility water to the heat exchanger. 1

Application Examples Semiconductor Example: Temperature control of chamber electrode Upper electrode Medical Example: Blood preservation Wafer Lower electrode Etching equipment Spatter equipment Cleaning equipment Coating equipment Dicing equipment Tester, etc. X-ray instrument MRI Blood preservation equipment HRG Food Example: Tofu (Bean curd) production Analysis Example: Electronic microscope Electronic microscope CRT HRS Bottle-cleaning machine Tofu (Bean curd) production equipment Noodle-making machine, etc. Water temperature control for forming tofu by mixing the boiled soybean milk and bittern Machine tool Example: Laser machining Electron microscope X-ray analytical instrument Gas chromatography Sugar level analytical instrument, etc. Prevents the distortion caused by the heat generated by the electronic gun in an electronic microscope. Printing Example: Printing temperature control Ink roller HRZD Wire cutting Grinder Spot welding Plasma welding Laser machining, etc. Temperature-controlling the laser generating tube enables the laser wave length to be optimised, improving the accuracy of the machined cross sectional area. Offset printing machine Automatic developing machine UV equipment, etc. Temperature-controlling the ink roller enables to control the evaporation amount and viscosity of an ink and optimise the tint of colors. Molding Example: Injection molding HEC HEB HRZ Plastic molding Rubber molding Wire cable coating machine Injection molding, etc. Temperature-controlling the mold results in improved product quality. 11

Series Model Selection Guide to Model Selection Required Cooling Capacity Calculation Precautions on Model Selection Circulating Fluid Typical Physical Property Values Page 14 Page 15, 16 Page 16 Page 17 Fluorinated Fluid Type How to Order/Specifications Cooling Capacity/Heating Capacity/ Pump Capacity Ethylene Glycol Type How to Order/Specifications Cooling Capacity/Heating Capacity/ Pumping Capacity Clear/Deionized Water Type How to Order/Specifications Cooling Capacity/Heating Capacity/ Pumping Capacity Common Specifications Dimensions Communication Function Contact Input/Output Serial RS-485 Connector Location Operation Panel Display Alarm Options Analog Communication DeviceNet Communication NPT Fitting DI Control Kit Circulating Fluid Automatic Recovery Optional Accessories By-pass Piping Set Anti-quake Bracket 4-Port Manifold DI Filter Insulating Material for DI Filter Contaminant Filter 6% Ethylene Glycol Aqueous Solution Concentration Meter Specific Product Precautions Page 18 Page 19 Page 11 Page 111 Page 112 Page 113 Page 114 Page 115 Page 115 Page 116 Page 116 Page 117 Page 117 Page 118 Page 118 Page 118 Page 118 Page 119 Page 12 Page 12 Page 121 Page 121 Page 121 Page 122 Page 122 Page 122 Page 123 to 125 HRG HRS HRZ HRZD HEC HEB 13

Series Model Selection Guide to Model Selection 1. How much is the temperature in degrees centigrade for the circulating fluid? Temperature range which can be set with the Thermo-chiller H: 68 to 195 F (2 C to 9 C) Example) Customer requirement: 122 F (5 C) 2.What kind of the circulating fluids will be used? Relationship between circulating fluid (which can be used with the Thermo-chiller) and temperature Fluorinated fluids: Fluorinert FC-4/GALDEN HT2 6% ethylene glycol aqueous solution Clear water/deionized water 68 F (2 C) 194 F (9 C) Example) Customer requirement: Clear water 3. How much is the temperature in degrees centigrade for the facility water? Temperature range which can be set with the Thermo-chiller 1 C to 35 C Example) Facility water temperature of customer s machine: 15 C Temperature difference between the circulating fluid and facility water is: 5 15 = 95 F (35 C). 4.What is the kw for the required cooling capacity? Example) Customer requirement: 2 kw Plot the point where the temperature difference between the circulating fluid and facility water (95 F (35 C)) intersects the cooling capacity (2 kw) in the cooling capacity graph. [Cooling Capacity Graph] Circulating Fluid: Clear Water/Deionized Water 35 5 7 9 95 11 1 15 17 F -H2 Cooling capacity (kw) 25 2 15 1 Customer requirement 15-H2 8-H2 5 2-H2 1 2 35 4 5 6 7 8 Temperature difference t ( C) ( temperature Facility water temperature) The point plotted in the graph is the requirement from your customer. Select the Thermo-chiller models exceeding this point. In this case, select the -H2. Fluorinert is a trademark of 3M. GALDEN is a registered trademark of Solvay Solexis, Inc. 14

Model Selection Series Required Cooling Capacity Calculation Example 1: When the heat generation amount in the customer s machine is known. Heat generation amount Q: 3.5 kw Cooling capacity = Considering a safety factor of 2%, 3.5 x 1.2 = 4.2 kw Example 2: When the heat generation amount in the customer s machine is not known. Obtain the temperature difference between inlet and outlet by circulating the circulating fluid inside the customer s machine. Heat generation amount Q : Unknown temperature difference T (= T2 T1) : 6. C (6. K) outlet temperature T1 : 2 C (293.15 K) return temperature T2 : 26 C (299.15 K) flow rate L : 2 L/min : Fluorinated fluid Refer to page 17 for the typical physical property values by circulating fluid. Q = T x L x γ x C 6 x 1 = 6. x 2 x 1.8 x 1 3 x.96 x 1 3 =3456 W = 3.5 kw 6 x 1 Density γ: 1.8 x 1 3 kg/m 3 Specific heat C:.96 x 1 3 J/(kg K) (at 2 C) Cooling capacity = Considering a safety factor of 2%, 3.5 x 1.2 = 4.2 kw Example of conventional measurement units (Reference) Unknown 6. C 2 C 26 C 1.2 m 3 /h Fluorinated fluid Density γ: 1.8 x 1 3 kg/m 3 Specific heat C:.23 kcal/kg C (at 2 C) Refer to page 17 for the typical physical property values by circulating fluid. Q = T x L x γ x C 86 = 6. x 1.2 x 1.8 x 1 3 x.23 86 =3.5 kw Cooling capacity = Considering a safety factor of2%, 3.5 x 1.2 = 4.2 kw HEC HRZD HRZ HRS HRG Thermo-chiller T2: Return temperature L T = T2 T1 T1: Outlet temperature Customer s machine HEB 15

Series Required Cooling Capacity Calculation Example 3.When there is no heat generation, and when cooling the object below a certain temperature and period of time. Cooled substance total volume V Cooling time h Cooling temperature difference T Facility water temperature Refer to page 17 for the typical physical property values by circulating fluid. Q = T x V x γ x C h x 6 x 1 Thermo-chiller : 6 L : 15 min : 2 C (2 K) (7 C 5 C 2 C) : 2 C (293.15 K) : Fluorinated fluid 2 x 6 x 1.74 x 1 3 x 1.5 x 1 3 15 x 6 x 1 Density γ: 1.74 x 1 3 kg/m 3 Specific heat C: 1.5 x 1 3 J/(kg K) Water bath (at 5 C) =2436 W = 2.4 kw Cooling capacity = Considering a safety factor of 2%, 2.4 x 1.2 = 2.9 kw (When the circulating fluid temperature is 5 C.) (In this case, selected Thermo-chiller model will be the 8-H.) Example of conventional measurement units (Reference).6 m 3.25 h 2 C 2 C Fluorinated fluid Density γ: 1.74 x 1 3 kg/m 3 Specific heat C:.25 kcal/kg C (at 5 C) Refer to page 17 for the typical physical property values by circulating fluid. Q = T x V x γ x C h x 86 = 2 x.6 x 1.74 x 13 x.25.25 x 86 =2.4 kw Cooling capacity = Considering a safety factor of2%, 2.4 x 1.2 = 2.9 kw (When the circulating fluid temperature is 5 C.) 5 C V (In this case, selected Thermo-chiller model will be the 8-H.) Precautions on Model Selection After 15 min, cool 7 C down to 5 C. Note) This is the calculated value by changing the fluid temperature only. Thus, it varies substantially depending on the water bath or piping material or shape. 1. Temperature difference between the circulating fluid and facility water The series exchanges heat between the circulating fluid and facility water directly, so it may not be possible to lower the circulating fluid temperature to the set temperature if the facility water temperature is too high. Check that the facility water temperature can be maintained for the circulating fluid temperature referring to the cooling capacity graph of each model before using. 2. Heating capacity When setting the circulating fluid temperature at a higher temperature than the room temperature, the circulating fluid temperature will be heated with the Thermo-chiller. Heating capacity varies depending on the circulating fluid temperature. Also, the heating capacity varies depending on the circulating fluid temperature. Consider the heat radiation amount or thermal capacity of the customer s equipment. Check beforehand if the required heating capacity is provided, based on the heating capacity graph for the respective model. 3. Pump capacity < flow rate> Pump capacity varies depending on the model selected from the series. Also, circulating fluid flow varies depending on the circulating fluid discharge pressure. Consider the installation height difference between our Thermo-chiller and a customer s machine, and the piping resistance such as circulating fluid pipings, or piping size, or piping curves in the machine. Check beforehand if the required flow rate is achieved, using the pump capacity curves for each respective model. < discharge pressure> discharge pressure has the possibility to increase up to the maximum pressure in the pump capacity curves for the respective model. Check beforehand if the circulating fluid pipings or circulating fluid circuit of the customer s machine are fully durable against this pressure. 16

Model Selection Series Circulating Fluid Typical Physical Property Values The below shown are reference values. Please contact circulating fluid supplier for details. Fluorinated Fluids Physical property value Temperature Density γ [kg/m 3 ] [g/l] [J/(kg K)] Specific heat C ([kcal/kg C]) 1 C 1.87 x 1 3.87 x 1 3.21 2 C 1.8 x 1 3.96 x 1 3.23 5 C 1.74 x 1 3 1.5 x 1 3.25 8 C 1.67 x 1 3 1.14 x 1 3.27 HRG 6% Ethylene Glycol Aqueous Solution Physical property value Temperature Density γ [kg/m 3 ] [g/l] [J/(kg K)] Specific heat C ([kcal/kg C]) HRS 1 C 1.1 x 1 3 3.2 x 1 3.72 2 C 5 C 8 C 1.8 x 1 3 1.6 x 1 3 1.4 x 1 3 3.15 x 1 3 3.27 x 1 3 3.4 x 1 3.75.78.81 HRZ Water Density γ: 1 x 1 3 [kg/m 3 ] [g/l] Specific heat C: 4.2 x 1 3 [J/(kg K)] (1. [kcal/kg C]) HRZD HEB HEC 17

Thermo-chiller Fluorinated Fluid Type Series How to Order SEMI Fluorinated Fluid Type 2 H Cooling capacity Symbol Cooling capacity 2 2 kw 8 8 kw 15 15 kw kw Temperature range setting Symbol Temperature range setting H 68 to 194 F (2 to 9 C) Specifications (For details, please consult our Product Specifications information.) Option Symbol Option Nil None C Analog communication D DeviceNet communication N NPT fitting Z automatic recovery Pump inverter control Symbol Pump inverter control Nil None S Applicable (Pump inverter type) Model Cooling method Note 1) Ambient temperature/humidity Note 2) Temperature range setting Note 1) Cooling capacity (5/6 Hz common) (kw) temperature Facility water temperature rated flow Facility water required flow rate system Facility water system Electrical system Conditions Temperature stability Note 3) Pump capacity Note 4) (5/6 Hz)(MPa) flow range Note 5) (L/min) Note 6) Tank capacity recovery tank volume Note 7) Port size Wetted parts material Temperature range Note 8) Required flow rate Inlet pressure range Port size Wetted parts material Power supply Max. operating current Breaker capacity Communications Dimensions Note 9) Weight Note 1) Safety standards (A) (A) Note 1) It should have no condensation. Note 2) Fluorinert is a trademark of 3M and GALDEN is a registered trademark of Solvay Solexis, Inc. Regarding the fluid other than the above, please contact SMC. Note 3) Outlet temperature when the circulating fluid and facility water are rated flow, and the circulating fluid outlet and return port are directly connected. Installation environment, power supply, and facility water are within specification range and stable. Value obtained 1 minutes after the external load is stabilized. It may be out of ±.54 F (±.3 C) in some other operating conditions. Note 4) The capacity at the circulating fluid outlet when the circulating fluid temperature is 68 F (2 C). Pump capacity at 6 Hz indicates the maximum capacity of the -HS (pump inverter type). 18 2-H 8-H 15-H -H 2-HS 8-HS 15-HS -HS Water-cooled Temperature: 5 to 95 F (1 to 35 C), Humidity: to 7%RH Fluorinert FC-4/GALDEN HT2 68 to 194 F (2 to 9 C) 2 8 15 29 Facility water temperature +27 F (15 C) 5 to 95 F (1 to 35 C) 1.1 gpm (4 L/min) 7.9 gpm ( L/min) 1.6 gpm (4 L/min) 1.6 gpm (4 L/min) 2.6 gpm (1 L/min) 5.3 gpm (2 L/min) 6.6 gpm (25 L/min) 1.6 gpm (4 L/min) ±.54 F (±.3 C).4/.6 (at 4 L/min).45/.65 (at L/min).4/.6 (at 4 L/min).4/.6 (at 4 L/min).8 to 4.2 gpm (3 to 16 L/min) 2.4 to 13.2 gpm (9 to 5 L/min) Approx. 3.4 gal (13 L) Approx. 3.7 gal (14 L) 3.2 gal (12 L) Rc3/4 Copper brazing (Heat exchanger), Stainless steel, EPDM, Silicone, PPS, Fluororesin 5 to 95 F (1 to 35 C) 2.6 gpm (1 L/min) 5.3 gpm (2 L/min) 6.6 gpm (25 L/min) 1.6 gpm (4 L/min) 44 to 12 psi (.3 to.7 MPa) Rc3/4 Copper brazing (Heat exchanger), Stainless steel, EPDM, Silicone, Bronze, Brass 3-phase 2/2 to 28 VAC ±1% 26 Serial RS-485 (D-sub 9 pin) and Contact input/output (D-sub 25 pin) W15 in (38mm) x D26.2 in (665mm) x H33.9 in (86 mm) Approx. 198 lbs (9 kg) Approx. 22 lbs (1 kg) UL, CE marking, SEMI (S2-73, S8-113, F47-2), SEMATECH (S2-93, S8-95) Note 5) Applicable to the -HS (pump inverter type) only. Note 6) Minimum volume required for operating only the Thermo-chiller. ( temperature: 68 F (2 C), including the Thermo-chiller s internal pipings or heat exchanger) Note 7) The automatic circulating fluid recovering function will be provided by selecting option Z for collecting the circulating fluid inside an external piping. Note 8) Required flow rate for cooling capacity or maintaining the temperature stability. Note 9) Panel dimensions.these dimensions do not include possible protrusions such as a breaker handle. Note 1) Weight in the dry state without circulating fluids

Thermo-chiller Series Cooling Capacity 2-H/8-H/15-H/-H 2-HS/8-HS/15-HS/-HS Cooling capacity (kw) Heating Capacity 2-H/8-H/15-H/-H 2-HS/8-HS/15-HS/-HS 5 7 9 11 1 15 17 F 5 7 9 11 1 15 17 19 F 35 25 2 15 1 5 -H 15-H 8-H 2-H 7 6 5 4 3 2 1 1 2 4 5 6 7 8 1 2 4 5 6 7 8 9 Temperature difference t ( C) ( temperature Facility water temperature) Heating capacity (kw) temperature ( C) HRG HRS When pump inverter is operating at frequency of 6 Hz (maximum). HEB HEC HRZD HRZ Pump Capacity 2-H 2-HS pressure (psi) 145 1 12 1 9 75 6 45 15 : Fluorinated fluids temperature: 68 F (2 C) 1 2 3 4 5 gpm Outlet pressure [5 Hz] Return port pressure Outlet pressure [6 Hz] 2 4 6 8 1 12 14 16 18 2 Flow rate (L/min) If the circulating fluid flow drops below.53 gpm (2 L/min)., the shutdown alarm activates and operation stops. Do not use the product when the flow exceeds 4.23 gpm (16 L/min)., since the flow cannot be displayed accurately. Pump capacity at 6 Hz indicates the maximum capacity of the 2-HS (pump inverter type). 8-H/15-H/-H 8-HS/15-HS/-HS pressure (psi) : Fluorinated fluids temperature: 68 F (2 C) 145 2 4 6 8 1 12 14 gpm 1 Outlet pressure 12 [6 Hz] 1 9 Outlet pressure [5 Hz] 75 6 45 15 Return port pressure 5 1 15 2 25 35 4 45 5 55 6 Flow rate (L/min) If the circulating fluid flow drops below 2.1 gpm (8 L/min)., the shutdown alarm activates and operation stops. Do not use the product when the flow exceeds 13.2 gpm (5 L/min)., since the flow cannot be displayed accurately. Pump capacity at 6 Hz indicates the maximum capacity of the 8-HS/15-HS/-HS (pump inverter type). 19

Ethylene Glycol Type Thermo-chiller Series How to Order 2 H 1 Cooling capacity Symbol Cooling capacity 2 2 kw 8 8 kw 15 15 kw kw Temperature range setting Symbol Temperature range setting H 68 to 194 F (2 to 9 C) Ethylene glycol type Specifications (For details, please consult our Product Specifications information.) Ethylene Glycol Type SEMI Option Symbol Option Nil None C Analog communication D DeviceNet communication N NPT fitting Y DI control kit Z automatic recovery Pump inverter control Symbol Pump inverter control Nil None S Applicable (Pump inverter type) system Facility water system Electrical system Model Cooling method Note 1) Ambient temperature/humidity Note 2) Temperature range setting Note 1) Water-cooled Temperature: 5 to 95 F (1 to 35 C), Humidity: to 7%RH 6% ethylene glycol aqueous solution 68 to 194 F (2 to 9 C) 2-H1 8-H1 15-H1 -H1 2-H1S 8-H1S 15-H1S -H1S Cooling capacity (5/6 Hz common) (kw) 2 8 15 27 temperature Facility water temperature Facility water temperature +27 F (15 C) 5 to 95 F (1 to 35 C) rated flow Facility water required flow rate 1.1 gpm (4 L/min) 2.6 gpm (1 L/min) 4. gpm (15 L/min) 4. gpm (15 L/min) 7.9 gpm ( L/min) 6.6 gpm (25 L/min) 1.6 gpm (4 L/min) 1.6 gpm (4 L/min) Temperature stability Note 3) ±.54 F (±.3 C) Pump capacity Note 4) (5/6 Hz) Note 5) flow range.35/.55 (at 4 L/min).8 to 4.2 gpm (3 to 16 L/min).45/.65 (at 15 L/min).4/.6 (at L/min) 2.4 to 13.2 gpm (9 to 5 L/min).35/.55 (at 4 L/min) Tank capacity Note 6) recovery tank volume Note 7) Port size Wetted parts material Temperature range Approx. 3.4 gal (13 L) 3.2 gal (12 L) Rc3/4 Nickel brazing (Heat exchanger), Stainless steel, EPDM, Silicone, PPS, Fluororesin 5 to 95 F (1 to 35 C) Required flow rate Note 8) 2.6 gpml (1 L/min) 4. gpm (15 L/min) 6.6 gpm (25 L/min) 1.6 gpm (4 L/min) Inlet pressure range Port size Wetted parts material Power supply Max. operating current (A) 44 to 12 psi (.3 to.7 MPa) Rc3/4 Nickel brazing (Heat exchanger), Stainless steel, EPDM, Silicone, Bronze, Brass 3-phase 2/2 to 28 VAC ±1% 26 Breaker capacity (A) Communications Dimensions Note 9) Weight Note 1) Safety standards Serial RS-485 (D-sub 9 pin) and Contact input/output (D-sub 25 pin) W15 in (38mm) x D 26.2 in (665mm) x H33.9 in (86mm) Approx. 198 lbs (9 kg) UL, CE marking, SEMI (S2-73, S8-113, F47-2), SEMATECH (S2-93, S8-95) Conditions Note 1) It should have no condensation. Note 2) Dilute pure ethylene glycol with clear water. Additives invading wetting parts material such as preservatives cannot be used. Note 3) Outlet temperature when the circulating fluid and facility water are rated flow, and the circulating fluid outlet and return port are directly connected. Installation environment, power supply, and facility water are within specification range and stable. Value obtained 1 minutes after the external load is stabilized (after stabilization with no load for -H1). It may be out of this range when a DI control kit (optiony) is used or in some other operating conditions. 11 Note 4) The capacity at the circulating fluid outlet when the circulating fluid temperature is 68 F (2 C). Pump capacity at 6 Hz indicates the maximum capacity of the -H1S (pump inverter type). Note 5) Applicable to the -H1S (pump inverter type) only. Note 6) Minimum volume required for operating only the Thermo-chiller. ( temperature: 68 F (2 C), including the Thermo-chiller s internal pipings or heat exchanger) Note 7) The automatic circulating fluid recovering function will be provided by selecting option Z for collecting the circulating fluid inside an external piping. Note 8) Required flow rate for cooling capacity or maintaining the temperature stability. Note 9) Panel dimensions.these dimensions do not include possible protrusions such as a breaker handle. Note 1) Weight in the dry state without circulating fluids

Thermo-chiller Series Cooling Capacity 2-H1/8-H1/15-H1/-H1 2-H1S/8-H1S/15-H1S/-H1S Heating Capacity 2-H1/8-H1/15-H1/-H1 2-H1S/8-H1S/15-H1S/-H1S 5 7 9 11 1 15 17 F 5 7 9 11 1 15 17 19 F 35 7 Cooling capacity (kw) 25 2 15 1 5 2-H1 1 2 4 5 6 7 8 Temperature difference t ( C) ( temperature Facility water temperature) 6 5 4 3 2 1 1 2 4 5 6 7 8 9 temperature ( C) HRG HRS Pump Capacity 8-H1/15-H1/-H1 8-H1S/15-H1S/-H1S HRZ HRZD HEC HEB -H1 15-H1 8-H1 Heating capacity (kw) 2-H1 2-H1S pressure (psi) : 6% ethylene glycol temperature: 68 F (2 C) : 6% ethylene glycol temperature: 68 F (2 C) 1 2 3 4 5 gpm 145 145 2 4 6 8 1 12 14 gpm 1 1 12 12 Outlet pressure [6 Hz] 1 1 9 Outlet pressure 9 Outlet pressure [6 Hz] 75 75 [5 Hz] 6 6 45 45 Outlet pressure [5 Hz] Return port pressure 15 Return port pressure 15 2 4 6 8 1 12 14 16 18 2 5 1 15 2 25 35 4 45 5 55 6 Flow rate (L/min) Flow rate (L/min) If the circulating fluid flow drops below.53 gpm (2 L/min)., the shutdown alarm activates and operation stops. Do not use the product when the flow exceeds 4.23 gpm(16 L/min)., since the flow cannot be displayed accurately. Pump capacity at 6 Hz indicates the maximum capacity of the 2-H1S (pump inverter type). pressure (psi) If the circulating fluid flow drops below 2.1 gpm (8 L/min)., the shutdown alarm activates and operation stops. Do not use the product when the flow exceeds 13.2 gpm (5 L/min)., since the flow cannot be displayed accurately. Pump capacity at 6 Hz indicates the maximum capacity of the 8-H1S/15-H1S/-H1S (pump inverter type). 111

Thermo-chiller Series How to Order Clear/Deionized Water Type SEMI Clear/Deionized Water Type 2 H 2 Cooling capacity Symbol Cooling capacity 2 2 kw 8 8 kw 15 15 kw kw Temperature range setting Symbol Temperature range setting H 68 to 194 F (2 to 9 C) Clear/Deionized water type Specifications (For details, please consult our Product Specifications information.) Option Symbol Option Nil None C Analog communication D DeviceNet communication N NPT fitting Y DI control kit Z automatic recovery Pump inverter control Symbol Pump inverter control Nil None S Applicable (Pump inverter type) Model Cooling method Ambient temperature/humidity Note 1) Note 2) Temperature range setting Note 1) Cooling capacity (5/6 Hz common) (kw) temperature Facility water temperature rated flow Facility water required flow rate system Facility water system Electrical system Conditions Temperature stability Note 3) Pump capacity Note 4) (5/6 Hz) flow range Note 5) Tank capacity Note 6) recovery tank volume Note 7) Port size Wetted parts material Temperature range Note 8) Required flow rate Inlet pressure range Port size Wetted parts material Power supply Max. operating current Breaker capacity Communications (A) (A) Dimensions Note 9) Weight Note 1) Safety standards Note 1) It should have no condensation. Note 2) If clear water or deionized water is used, please use water that conforms to Water Quality Standards of the Japan Refrigeration and Air Conditioning Industry Association (JRA GL-2-1994/cooling water system - circulation type - make-up water).the electrical conductivity of the deionized water used as the fluid varies depending on the operating conditions. Note 3) Outlet temperature when the circulating fluid and facility water are rated flow, and the circulating fluid outlet and return port are directly connected. Installation environment, power supply, and facility water are within specification range and stable. Value obtained 1 minutes after the external load is stabilized (after stabilization with no load for -H2). It may be out of this range when a DI control kit (option Y) is used or in some other operating conditions. 112 2-H2 8-H2 15-H2 -H2 2-H2S 8-H2S 15-H2S -H2S Water-cooled Temperature: 5 to 95 F (1 to 35 C), Humidity: to 7%RH Clear water, Deionized water 68 to 194 F (2 to 9 C) 2 8 15 Facility water temperature +27 F (15 C) 5 to 95 C (1 to 35 C) 1.1 gpm (4 L/min) 4. gpm (15 L/min) 7.9 gpm ( L/min) 1.6 gpm (4 L/min) 2.6 gpm (1 L/min) 4. gpm (15 L/min) 6.6 gpm (25 L/min) 1.6 gpm (4 L/min) ±.54 F (±.3 C).35/.55 (at 4 L/min).45/.65 (at 15 L/min).4/.6 (at L/min).35/.55 (at 4 L/min).8 to 4.2 gpm (3 to 16 L/min) 2.4 to 13.2 gpm (9 to 5 L/min) Approx. 3.4 gal (13 L) 3.2 gal (12 L) Rc3/4 Nickel brazing (Heat exchanger), Stainless steel, EPDM, Silicone, PPS, Fluororesin 5 to 95 F (1 to 35 C) 2.6 gpm (1 L/min) 4. gpm (15 L/min) 6.6 gpm (25 L/min) 1.6 gpm (4 L/min) 44 to 12 psi (.3 to.7 MPa) Rc3/4 Nickel brazing (Heat exchanger), Stainless steel, EPDM, Silicone, Bronze, Brass 3-phase 2/2 to 28 VAC ±1% 26 Serial RS-485 (D-sub 9 pin) and Contact input/output (D-sub 25 pin) W15in (38 mm) x D 26.2 in (665 mm) x H33.9 in (86 mm) Approx. 198 bls (9 kg) UL, CE marking, SEMI (S2-73, S8-113, F47-2), SEMATECH (S2-93, S8-95) Note 4) The capacity at the circulating fluid outlet when the circulating fluid temperature is 68 F (2 C). Pump capacity at 6 Hz indicates the maximum capacity of the -H2S (pump inverter type). Note 5) Applicable to the -H2S (pump inverter type) only. Note 6) Minimum volume required for operating only the Thermo-chiller. (Circulating fluid temperature: 68 F (2 C), including the Thermo-chiller s internal pipings or heat exchanger) Note 7) The automatic circulating fluid recovering function will be provided by selecting option Z for collecting the circulating fluid inside an external piping. Note 8) Required flow rate for cooling capacity or maintaining the temperature stability. Note 9) Panel dimensions. These dimensions do not include possible protrusions such as a breaker handle. Note 1) Weight in the dry state without circulating fluids

Thermo-chiller Series Cooling Capacity 2-H2/8-H2/15-H2/-H2 2-H2S/8-H2S/15-H2S/-H2S Heating Capacity 2-H2/8-H2/15-H2/-H2 2-H2S/8-H2S/15-H2S/-H2S 5 7 9 11 1 15 17 F 5 7 9 11 1 15 17 19 F 35 7 25 2 15 1 5 2-H2 1 2 4 5 6 7 8 Temperature difference t ( C) ( temperature Facility water temperature) 6 5 4 3 2 1 1 2 4 5 6 7 8 9 temperature ( C) HRG HRS HEB HEC HRZD HRZ Cooling capacity (kw) -H2 15-H2 8-H2 Heating capacity (kw) Pump Capacity 2-H2 2-H2S pressure (psi) : Clear water temperature: 68 F (2 C) 8-H2/15-H2/-H2 8-H2S/15-H2S/-H2S 145 1 2 3 4 5 gpm 145 2 4 6 8 1 12 14 gpm 1 1 12 12 Outlet pressure 1 1 [6 Hz] 9 Outlet pressure 9 Outlet pressure 75 [6 Hz] 75 [5 Hz] 6 6 45 45 Outlet pressure [5 Hz] Return port pressure 15 Return port pressure 15 2 4 6 8 1 12 14 16 18 2 5 1 15 2 25 35 4 45 5 55 6 Flow rate (L/min) Flow rate (L/min) If the circulating fluid flow drops below.53 gpm (2 L/min)., the shutdown alarm activates and operation stops. Do not use the product when the flow exceeds 4.23 gpm (16 L/min)., since the flow cannot be displayed accurately. Pump capacity at 6 Hz indicates the maximum capacity of the 2-H2S (pump inverter type). pressure (psi) : Clear water temperature: 68 F (2 C) If the circulating fluid flow drops below 2.1 gpm (8 L/min)., the shutdown alarm activates and operation stops. Do not use the product when the flow exceeds 13.2 gpm (5 L/min)., since the flow cannot be displayed accurately. Pump capacity at 6 Hz indicates the maximum capacity of the 8-H2S/15-H2S/-H2S (pump inverter type). 113

SMC SMC REMOTE RUN ALARM SEL ENT START/STOP RESET Dimensions Series Common Specifications Rear side Front side OPEN CLOSE Emergency off [EMO] switch (Red, ø1.6in (ø4 mm) With a guard ring (yellow) Power cable entry D Cooling fan for the unit inside (exhaust) 3 in (75 mm) or less B Operation display panel 2.2 in (55 mm) or less Breaker handle A Plate Facility water inlet Rc3/4 (with plug) outlet Rc3/4 (with plug) Handle return port for DI filter Note) Rc1/4 (with plug) return port Rc3/4 (with plug) Facility water outlet Rc3/4 (with plug) CLOSE OPEN fill port level gauge Tank drain port Rc3/8 (with valve/plug) outlet for DI filter Note) Rc1/4 (with plug) C Ventilation (expiration) Drain pan port Rc3/8 (with plug) Bolt for fixing the anti-quake bracket M8 stud bolt Caster (unfixed) with brake Bolt for fixing the anti-quake bracket M8 stud bolt Note) Only when the DI control kit (option Y) is selected. Model Fluorinated fluid type Ethylene glycol type Clear/Deionized water type 2-H 8-H 15-H -H 2-H1 8-H1 15-H1 -H1 2-H2 8-H2 15-H2 -H2 Unit: Inch (mm) A B C D 15 26.2 33.9 ø.7 x.81 (38) (665) (86) (ø18.5 to 2.5) 114

Common Specifications Series Communication Function (For details, please consult our Communication Specifications information.) Contact Input/Output Item Connector no. Connector type (on this product side) Fixing bolt size Insulation method Rated input voltage Input signal Operating voltage range Rated input current Input impedance Rated load voltage Output signal Maximum load current (total) Rated load voltage Alarm signal Maximum load current Rated load voltage EMO signal Maximum load current Specifications P1 D-sub 25 P type, Female connector M2.6 x.45 Photocoupler 24 VDC 21.6 to 26.4 VDC 5 ma TYP 4.7 kω 48 VAC or less/ VDC or less When using the power supply of the Thermo-chiller: 2 ma DC (resistance load/inductive load) When using the power supply of the customer s machine: 8 ma AC/DC (resistance load/inductive load) 48 VAC or less/ VDC or less 8 ma AC/DC (resistance load/inductive load) 48 VAC or less/ VDC or less 8 ma AC/DC (resistance load/inductive load) HRG HRS To the Thermo-chiller Customer s machine side HRZ 24 VDC 24 COM 4.7 kω 4.7 kω 4.7 kω 4.7 kω 1 14 3 16 4 17 Pin assignment number 24 VDC output 24 COM output Setting at the time of shipment from factory Run/Stop signal Custom function Note) Run/Stop signal 1 Run/Stop signal 2 DIO REMOTE signal 1 DIO REMOTE signal 2 Input signal HRZD Circuit diagram Digital circuit 6 19 7 2 Operation condition signal Warning signal Fault signal Remote signal Output signal 1 Output signal 2 Output signal 3 Output signal 4 HEB HEC 8 15 5 Temp Ready signal Contact output COM Output signal 5 Contact output COM Output signal 18 Alarm signal Alarm signal Note) The custom function is equipped for contact input/output. Using the custom function enables the customer to set the signal type for contact input/output or pin assignment numbers. For details, please consult Communication Specifications information. 24 COM Emergency off [EMO] switch 13 25 EMO signal EMO signal 115

Series Communication Function (For details, please consult our Communication Specifications information.) Serial RS-485 The serial RS-485 enables the following items to be written and read out. <Writing> Run/Stop temperature setting automatic recovery start/ stop 1 <Readout> present temperature flow discharge pressure electrical resistivity 2 Alarm occurrence information Status (operating condition) information 1 Only when the circulating fluid automatic recovery function (option Z) is selected. 2 Only when the DI control kit (option Y) is selected. Item Connector no. Connector type (on this product side) Fixing bolt size Standards Protocol Circuit diagram Specifications P2 D-sub 9 P type, Female connector M2.6 x.45 EIA RS485 Modicon Modbus To the Thermo-chiller Customer s machine side 2 SD+ 7 Internal circuit SD 5 SG Connector location P3: Not used for the maintenance purpose port D-sub 9 (Male receptacle) P2: Serial RS-485 D-sub 9 (Female receptacle) P1: Contact input/output D-sub 25 (Female receptacle) Power cable entry Rear side 116

Common Specifications Series Operation Display Panel q No. Description Function TEMP PV FLOW PV PRESS. 2. C 2.2LPM.56MPa LCD Operating condition of this unit/ discharge temperature/ flow/ discharge pressure/setting value/alarm message, etc. are displayed. i o! r t REMOTE RUN A LARM SEL ENT START/STOP RESET w e u [START/STOP] key [RESET] key [SEL] key [ENT] key [] [] key [] key [REMOTE] indicator [RUN] indicator [ALARM] indicator Starts/Stops the operation. Stops the alarm buzzing. Resets the alarm. Switches the display. Decides the settings. Moves the cursor and changes the setting values. Moves the cursor. Lights up when the unit is in the remote status. Lights up when the unit is in the operating status. Lights up when the unit is alarming. HRG HRS Alarm y HRZ This unit can display 23 kinds of alarm messages as standard. Also, it can read out the serial RS-485 communication. Alarm code 1 2 5 6 7 8 9 1 11 12 13 15 17 18 19 21 22 23 24 25 26 27 29 Alarm message Water Leak Detect FLT Incorrect Phase Error FLT Reservoir Low Level FLT Reservoir Low Level WRN Reservoir High Level WRN Temp. Fuse Cutout FLT Reservoir High Temp. FLT Return High Temp. WRN Reservoir High Temp. WRN Return Low Flow FLT Return Low Flow WRN Pump Breaker Trip FLT Interlock Fuse Cutout FLT DC Power Fuse Cutout WRN FAN Motor Stop WRN Controller Error FLT Memory Error FLT Communication Error WRN DI Low Level WRN Pump Inverter Error FLT DNET Comm. Error FLT DNET Comm. Error WRN F.Water Low Temp. WRN F.Water High Temp. WRN Operation status Stop Stop Stop Continue Continue Stop Stop Continue Continue Stop Continue Stop Stop Continue Continue Stop Stop Continue Continue Stop Stop Continue Continue Continue Main reason Liquid deposits in the drain pan of this unit. The power supply to this unit is incorrect. The amount of circulating fluid tank is running low. The amount of circulating fluid tank is running low. The amount of circulating fluid in the tank has increased. Temperature of the circulating fluid tank is raised. Temperature of the circulating fluid has exceeded the limitation. Temperature of returning circulating fluid has exceeded the limit. Temperature of the circulating fluid has exceeded the limitation set by the customer. The circulating fluid flow has gone below the limit. Flow rate of the Thermo-chiller has dropped below the set value. The protective equipment in the circulating fluid driving line has started. Overcurrent is flown to the control circuit. Overcurrent has flowed to the (optional) solenoid valve. (Only for the automatic circulating fluid recovery function - option Z) Cooling fan inside the compressor has stopped. The error occurred in the control systems. The data stored in the controller of this unit went wrong. The serial communications between this unit and customer s system has been suspended. DI level of the circulating fluid has gone below the limitation set by the customer. (Only for DI control kit - option Y) The error occurred in the circulating pump inverter. This alarm is applicable to the -HS only. The DeviceNet communications between this unit and customer s system has been suspended. (Only for DeviceNet communication specification - option D) An error has occurred in the DeviceNet communication system of this unit. (Only for DeviceNet communication specification - option D) Temperature of facility water has dropped below the set temperature. Temperature of facility water has exceeded the set temperature. HRZD HEC HEB 117

Series Options Note) Options have to be selected when ordering the Thermo-chiller. It is not possible to add them after purchasing the unit. C Option symbol Analog Communication D Option symbol DeviceNet Communication C D Analog communication In addition to the standard contact input/output signal communication and the serial RS-485 communication, analog communication function can be added. The analog communication function enables to write and read out the following items. <Writing> temperature setting <Readout> present temperature Electrical resistivity Only when the DI control kit (option Y) is selected. Scaling voltage - circulating fluid temperature can be set arbitrarily by the customer. For details, please consult our Communication Specifications information. DeviceNet communication In addition to the standard contact input/output signal communication and the serial RS-485 communication, DeviceNet function can be added. DeviceNet function enables to write and read out the following items. <Writing> Run/Stop temperature setting automatic recovery start/stop 1 <Readout> present temperature flow discharge pressure Electrical resistivity 2 Alarm occurrence information Status (operating condition) information 1 Only when the circulating fluid automatic recovery function (option Z) is selected. 2 Only when the DI control kit (option Y) is selected. For details, please consult our Communication Specifications information. N Option symbol NPT Fitting NPT fitting N An adapter is included to change the connection parts of circulating fluid piping and facility water piping to NPT thread type. The adapter must be installed by the customer. Y Option symbol DI Control Kit DI control kit Select this option if you want to maintain the electrical resistivity (DI level) of the circulating fluid at a certain level. However, some components have to be fitted by customer. For details, refer to specification table for this option. Please note that this is not applicable to the fluorinated liquid type. Y Applicable model Allowable circulating fluid DI level display range DI level set range Solenoid valve hysteresis for control DI level reduction alarm set range MΩcm MΩcm MΩcm MΩcm -H1-Y -H2-Y 6% ethylene glycol aqueous solution Deionized water to 2 to 2 Note) to.9 to 2 Note) The DI filter is needed to control the DI level. (SMC Part No.: HRZ-DF1) Please purchase additionally because the DI filter is not included in this option. Also, if necessary, additionally purchase the insulating material for the DI filter. (SMC Part No.: HRZ-DF2) DI tube (1 piece each attached for IN/OUT) Install the DI filter outside the Thermo-chiller for piping. Secure the space for installing the DI filter in the rear side of the Thermo-chiller. It may go outside of the temperature stability range of ±.3 C when this option is used in some operating conditions. DI filter (Optional accessories) (Refer to page 121.) Please order separately. Return port from DI filter Outlet port to DI filter 118

Options Series Z Option symbol Circulating Fluid Automatic Recovery Z automatic recovery Select this option for customers who want to use the circulating fluid automatic recovery function. The automatic recovery function is a device which can recover the circulating fluid inside pipings into a sub-tank of the Thermo-chiller by the external communication or operation display panel. Some components need to be fitted by the customer. For details, consult Product Specifications information for these options. Applicable model recoverable volume Note 1) Purge gas Purge gas supply port Purge gas supply pressure Purge gas filtration Regulator set pressure Recoverable circulating fluid temperature Recovery start/stop Timeout error Height difference with the customer system side Common for all models 3.2 gal (12 L) Nitrogen gas Note 2) Self-align fitting for O.D. ø.3in (ø8mm) 58 to 12 psi (.4 to.7 MPa).1 or less Note 3) 22 to 44 psi (.15 to.3 MPa) 5 to 14 F (1 to 4 C) Start: External communication Note 4) or operation display panel/stop: Automatic Timer from recovery start to completion Stops recovering when the timer turns to set time. Possible set range: 6 to sec, at the time of shipping from the factory: sec 32.8 ft (1 m) or less Note 1) This is the space volume of the sub-tank when the liquid level of the circulating fluid is within the specification. Guideline of the recovery volume is 8% of the circulating fluid recoverable volume. Note 2) Before piping, clean inside the pipings with air blow, etc. Use the piping with no dust generation by purge gas. When using resin tube, where necessary, use insert fittings, etc. in order not to deform the tubings when connecting to self-align fittings. Note 3) At the time of shipping from factory, it is set to 29 psi (.2 MPa). Note 4) For details, please consult our Communication Specifications information. HRZD HRZ HRS HRG Rc3/4 Approx. 4.3 in (11 mm) HEB HEC 119

By-pass Piping Set Series Optional Accessories Note) Necessary to be fitted by the customer. When the circulating fluid goes below the rated flow, cooling capacity will be reduced and the temperature stability will be badly affected. In such a case, use the by-pass piping set. Part no. -BP1 Applicable model Common for all models To circulating fluid outlet By-pass volume adjustment valve 2 x Rc3/4 To circulating fluid return port Mounting view (Rear side) Approx. 5.9 in (15 mm) Insulating material Anti-quake Bracket Unit: in (mm) Bracket for earthquakes Prepare the anchor bolts (M12) which are suited to the floor material by the customer. Part no. Applicable model HRZ-TK2 Common for all models Note) 2 pieces per set (for 1 unit) (HRZ-TK2) Anchor bolt (M12) 27.5 (699) 2 pieces per set (4 nuts are included.) Anti-quake bracket 4.4 (111) Top side Anchor bolt location 4 x ø14 (4 x ø.55) Front side Anti-quake bracket HRZ-TK2 12 Nut (M8) x 2 (Accessory to anti-quake bracket) Fit it on the opposite side similarly. 6.3 (16) Front side

Optional Accessories Series 4-Port Manifold 4-branching the circulating fluid enables 4 temperature controls at the maximum with the 1 unit Thermo-chiller. Order the heat insulator for 4 port manifold (-MA2) separately if necessary. Part no. -MA1 -MA2 Applicable model Common for all models HRZ HRZD HRS HRG Mounting view (Rear side) Approx. DI Filter ø8.9 in (226 mm) -MA1 (2 pcs./set) 4 x Rc1/2 -MA2 (2 pcs./set) This is the ion replacement resin to maintain the electric resistivity of the circulating fluid. Customers who selected the DI control kit (option Y) need to purchase the DI filter separately. Insulating Material for DI Filter When the DI filter is used at a high temperature, we recommend that you use this insulating material to protect the radiated heat from the DI filter or possible burns. We also recommend that you use this to prevent heat absorption from the DI filter and to avoid forming condensation. Part no. HRZ-DF2 Applicable model Common for all models which can select the DI control kit. (option Y) HEC HEB Approx. ø8.7 in (22 mm) Approx. 2in (58 mm) Weight: Approx. 44 lbs (2 kg) 121

Series Contaminant Filter A filter mounted in the circulating fluid circuit to eliminate the dust which is contained in the circulating fluid. (Filtration: 2 µm) It is provided with its own heat insulator. Part no. Applicable model -CF1 Common for all models -CF2 Note) The internal element of the contaminant filter (Part no.: -CF2) is a replacement part. The period in service depends on the operating conditions. Insulating material Rc3/4 Contaminant filter (Built-in filter element) Mounting view (Rear side) Approx. 7.4 in (188 mm) Insulating material -CF1 (Contaminant filter) -CF2 (Filter element) 6% Ethylene Glycol Aqueous Solution This solution can be used as a circulating fluid for ethylene glycol-type Thermo-chillers. (Capacity: 2.6 gal (1 L)) Concentration Meter This meter can be used to control the concentration of ethylene glycol aqueous solution regularly. Part no. HRZ-BR1 Applicable model Common for all ethylene glycol-type models Part no. HRZ-BR2 Applicable model Common for all ethylene glycol-type models Approx. 6.7 in (17 mm) Approx. 11 ih (28 mm) Approx. 9.1 in ( 2 mm) Approx. 1.4 in (35 mm) Approx. 9.1 in (2 mm) 122

Series Specific Product Precautions 1 Be sure to read this before handling. Refer to back page 1 for Safety Instructions and back pages 2 to 5 for Temperature Control Equipment Precautions. Design Warning 1. This catalog shows the specifications of a single unit. 1. For details, please consult our Product Specifications and thoroughly consider the adaptability between the customer s system and this unit. 2. Although the protection circuit as a single unit is installed, the customer is requested to carry out the safety design for the whole system. Caution Warning Selection 1. Model selection In order to select the correct Thermo-chiller model, the amount of thermal generation from the customer s system, the operating circulating fluid, and its circulating flow are required. Select a model, by referring to the guideline to model selection on page 14. 2. Option selection Options have to be selected when ordering the Thermo-chiller. It is not possible to add them after purchasing the unit. Handling 1. Thoroughly read the Operation Manual. Read the Operation Manual completely before operation, and keep this manual available whenever necessary. Operating Environment/Storage Environment Caution 1. Do not use in the following environment because it will lead to a breakdown. 1. Environment like written in Temperature Control Equipment Precautions. 2. Locations where spatter will adhere to when welding. 3. Locations where it is likely that the leakage of flammable gas may occur. 4. Locations where the ambient temperature exceeds the limits as mentioned below. During operation 5 to 95 F (1 to 35 C) During storage 32 to 122 F ( to 5 C) (but as long as water or circulating fluid are not left inside the pipings) 5. Locations where the ambient relative humidity exceeds the limit as mentioned below. During operation % to 7% During storage 15% to 85% 6. (Inside the operation facilities) locations where there is not sufficient space for maintenance. 7. In locations where the ambient pressure exceeds the atmospheric pressure. 2. The Thermo-chiller does not have clean room specification. It generates dust from the pump inside the unit and the cooling fan for the unit inside. Standard item Reference item Caution Circulating Fluid 1. Avoid oil or other foreign objects entering the circulating fluid. 2. Use ethylene glycol that does not contain additives such as preservatives. 3. The condensation of ethylene glycol aqueous solution must be 6% or less. If the condensation is too high, the pump will be overloaded, resulting in occurrence of Pump Breaker Trip FLT. 4. Avoid water moisture entering the fluorinated fluid. 5. Use clear water (including for diluting ethylene glycol aqueous solution) which must meet the water quality standards as mentioned below. Clear Water (as Circulating Fluid) Quality Standards The Japan Refrigeration and Air Conditioning Industry Association JRA GL-2-1994 Cooling water system Circulation type Make-up water Influence Item Unit Standard value Scale Corrosion generation ph (at 77 F (25 C) Electrical conductivity (77 F) Chloride ion (Cl ) Sulfuric acid ion (SO 2 4 ) Acid consumption amount (at ph4.8) Total hardness Calcium hardness (CaCO 3 ) Ionic state silica (SiO 2 ) Iron (Fe) Copper (Cu) Sulfide ion (S 2 ) Ammonium ion (NH 4+ ) Residual chlorine (Cl) Free carbon (CO 2 ) [µs/cm] [mg/l] [mg/l] [mg/l] [mg/l] [mg/l] [mg/l] [mg/l] [mg/l] [mg/l] [mg/l] [mg/l] [mg/l] 6. to 8. 1 to 5 or less 5 or less 5 or less 7 or less 5 or less or less.3 or less.1 or less Should not be detected..1 or less.3 or less 4. or less In the case of [MΩcm], it will be.3 to.1. : Factors that have an effect on corrosion or scale generation. Even if the water quality standards are met, complete prevention of corrosion is not guaranteed. Transportation/Transfer/Movement Warning 1. Transportation by forklift 1. It is not possible to hang this product. 2. The fork insertion position is either on the left side face or right side face of the unit. Be careful not to bump the fork against a caster or level foot and be sure to put through the fork to the opposite side. 3. Be careful not to bump the fork to the cover panel or piping ports. 2. Transportation by casters 1. This product is heavy and should be moved by at least two people. 2.Do not grip the pipings on the rear side or the handles of the panel. Fork insertion side Rear side Front side Fork insertion side HRG HRS HRZ HRZD HEC HEB 123