FDBZ290 Air sampling smoke detection kit

Similar documents
FDBZ290 Air sampling smoke detection kit

FDBZ290 Air sampling smoke detection kit Technical Manual

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

FDCIO223 (ES 45) Transponder

OOH740, OOHC740 Automatic fire detectors

Multi line separator module

Input module, input/output modules

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

FDCL221-M Multi line separator module

Input module, input/output module

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

OH720, OP720, HI720, HI722

FDOOT221, FDO221, FDT221

FDOOT241-9, FDOOT241-A, FDO241, FDT241

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

OOH740-A9-Ex Multisensor fire detector

Interbases. Sinteso FDSB221, FDSB228, FDSB229

FDA241, FDA221 Siemens ASD

Output module (230 V)

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

ASA linear smoke detector

FDCL221-Ex Line adapter (Ex)

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

FDOOT241-A9-Ex Multisensor fire detector

SWING radio fire detection system

OOH740-A9-Ex Multi-sensor fire detector

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Mimic display driver, LED ribbon cable

Radio fire detection system

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

FC723 Fire control panel

Fire control panels FC360

DC1192 Input /Output module

DM1131 / DM1133 / DM1134 Manual call points

FC724 Fire control panel

FC724 Fire control panel

DF1101-Ex Infrared flame detector

Fire control panels FC726 FC726-XA

FT2080 Fire terminal (Touch) Mounting Installation

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

FC722 Fire control panel

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

FT2080 Fire terminal (Touch) Mounting Installation

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Duct Temperature Sensors

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

FC722 Fire control panel

FC2020 Fire control panel

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

DF1151-Ex Infrared flame detector

XC10 Extinguishing control panels

FDA241, FDA221 Siemens ASD

XC10 combined fire detection and extinguishing control

DOW1171 / DCW1151 Radio fire detection system

FDCL221 Line separator

FDM273 Radio manual call point Mounting

FDL241-9 Linear smoke detector Mounting Commissioning

FDCI221, FDCIO221 Input module, input/output module Technical Manual

Fire control panel for modernization

FDOOT241-A9-Ex Automatic fire detector Technical Manual

XC10 combined fire detection and extinguishing control

FDCW241 Radio gateway Mounting

DT1101A / DT1102A / DO110xA Automatic fire detectors

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

FC2040. Fire control panel. Sinteso. FS20 series, MP6

For internal use only. Distribution (please mark): Product Solution Multi-channel x

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

Test units and accessories

Sinteso TM product catalog.

Test units and accessories

Synova TM product catalog.

FDOOT221, FDOOT241-A3, FDOOT241-A4, FDOOT241-8, FDOOT241-9, FDOOT241-A9, FDO241, FDO221, FDT241, FDT221 Automatic fire detectors Technical Manual

Test units and accessories

FP120-Z1 Power supply kit A (70 W) Technical Manual

FS20 Fire detection system

Building Technologies. FDUL221 en Line tester operating instructions for electricians

Room thermostat with 24-hour time switch and large LCD

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

FDS229 Alarm sounder with supplementary optical indication Technical Manual

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FD20 Sinteso Detector system

Fire safety products and accessories siemens.com/cerberus

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Frost Protection Thermostat

Electronic timeswitch

Frost Units for air temperature monitoring

FS720 Fire detection system (marine) Technical Manual

Call stations and extensions

MK8000 OPC Server Interface Specification for CS1115 Building Technologies

Application Sheet Chilled/heated ceiling (4 pipe) with 6-way valve on analog output

Room Temperature Sensors

RVL479. Heating Controller. for use with a partner unit

Room Temperature Controllers

ADAPTER FOR VENTILATION DUCT BWP-143A-SS (STAINLESS STEEL)

Transcription:

FDBZ290 Air sampling smoke detection kit Sinteso Cerberus PRO Reliable monitoring for smoke of supply air, exhaust air and recirculation ducts of air conditioning and ventilation systems Suitable for air speeds from 1 m/s to 20 m/s Complies with EN 54-27 with specialized Sinteso and Cerberus PRO smoke detectors Easy mounting with just one air flow tube Accessories for all forms of ventilation ducts Control Products and Systems

Function The air sampling smoke detection kit is a passive monitoring system without a fan of its own. It uses the pressure differences within the ventilation system to continuously take air samples from the ventilation duct via the air flow tube and supply them to the air sampling smoke detection kit. The air sampling smoke detection kit works only if the ventilation system is in operation and the air in circulation. The air to be monitored must usually be clean, i.e. free of dust and aerosols. If the smoke detector detects a certain concentration of smoke, the corresponding danger level is reported to the fire control panel which, in turn, triggers an alarm. Design The air sampling smoke detection kit consists of the following components: Air duct sampling chamber (gray plastic housing with a transparent cover) End plug for the air flow tube Screws for installing the detector base Screws for installing the air duct sampling chamber Smoke cap Plastic cable gland Plastic counter nut Air duct sampling chamber End plug Smoke cap Plastic cable gland M20 x 1.5 Plastic counter nut M20 x 1.5 The point detector and detector base listed must be ordered separately. Sinteso Cerberus PRO Base Detector Base Detector FDB222 FDB202 FDOOT241-A9 DB721 DB110 DB721D OOH740 2

Options Mounting bracket FDBZ290-AD Air flow tubes FDBZ290-AA,-AB,-AC Sealing kit FDBZ292-AD For uneven, round and insulated ducts incl. sealing sleeve, rubber seal and screws for installing the mounting bracket 600 mm, 1500 mm, 2800 mm Length (FDBZ290-AB, -AC incl. long end plug) Required when using the longer air flow tubes FDBZ290-AB, FDBZ290-AC Selecting a location The air sampling smoke detection kit is installed in the same location within a ventilation system in which air flow measuring instruments would normally be installed, i.e. where no air vortexes, changes of direction, branchings, constrictions or enlargements of the ventilation duct occur. To ensure a reliable smoke monitoring of the air, the air sampling smoke detection kit is installed after the last air inlet point. 3

Mounting variants The air sampling smoke detection kit is installed on the outside of the ventilation duct. Suitable for taking ventilation ducts with a diameter of 100 2700 mm. The air duct sampling chamber is usually installed on a rectangular ventilation duct using sheet-metal screws. With round and/or insulated ventilation ducts, the air sampling smoke detection kit is installed directly on the mounting bracket FDBZ290-AD. Round, insulated duct 600 mm Rectangular duct 600 mm FDBZ290-AD mounting bracket FDBZ290-AA air flow tube 600 mm Round, insulated duct >600 mm FDBZ290-AA air flow tube 600 mm Rectangular duct >600 mm FDBZ290-AD mounting bracket FDBZ292-AD sealing kit FDBZ290-Ax air flow tube 1500/2800 mm FDBZ292-AD sealing kit FDBZ290-Ax air flow tube 1500/2800 mm 4

Dimensions Technical data Housing of the air duct sampling chamber Material Protection category (IEC60529) Color Smoke detector/detector base System compatibility Air flow tube Permissible air speeds Air flow indicator ABS IP54 ~RAL 7001 silver grey See "Version" section Sinteso -> FDnet, collective Cerberus PRO -> C-NET, collective Aluminum 1 20 m/s 1 m/s Operating temperature -20...+50 C Air humidity 95 % rel. Approvals VdS G216035 Standards EN 54-27 when used with specialized Sinteso or Cerberus PRO smoke detectors 5

Details for ordering Type Order no. Designation Weight FDBZ290 S54319-S32-A1 Air sampling smoke detection kit 664 g FDBZ290-AA S54319-B33-A1 Air flow tube, length 600 mm 340 g FDBZ290-AB S54319-B33-A2 Air flow tube, length 1500 mm 850 g FDBZ290-AC S54319-B33-A3 Air flow tube, length 2800 mm 1570 g FDBZ290-AD S54319-B34-A1 Mounting bracket 402 g FDBZ292-AD A5Q00021367 Sealing kit 41 g FDOOT241-A9 S54310-F11-A1 Neural fire detector, ASA 106 g FDB222 S54319-F1-A1 Addressable detector base, flat 25 g FDB202 S54319-F3-F1 Collective detector base, flat 25 g OOH740 S54320-F7-A3 Multi-sensor smoke detector, ASA 124 g DB721 S54319-F11-A1 Detector base with loop contact DB721 52 g DB110 S54319-F5-A1 Detector base (collective) 52 g DB721D S54319-F15-A1 Detector base 54 g PSR720-2 S54319-F17-A1 Parameter set resistor 1 g - A5Q00004478 M20 x 1.5 metal cable gland 36 g - A5Q00004479 M20 x 1.5 metal counter nut 6 g You will find more information on the Sinteso fire detector FDOOT241-A9 in data sheet 008141. You will find more information about the Cerberus PRO fire detector OOH740 in data sheet A6V10284161. Issued by Siemens Switzerland Ltd Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41 724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2015 Technical specifications and availability subject to change without notice. Document no. A6V10405166_d_en_-- FD20/FD720 manual Edition 2016-04-29 Tab 3 / 3