Disabled persons toilet alarm kit from Cameo Systems

Similar documents
Accessible Toilet Alarm

Emergency Assist Alarm Kit Single Zone

Installation Guide. Disabled Persons Emergency Alarm Kit. Single Zone Call Control/Call answered unit c/w Sounder LED indicators and Braille lettering

Disabled Persons Toilet Alarm Kit

DISABLED TOILET / EMERGENCY ASSISTANCE ALARMS

EMERGENCY ASSISTANCE ALARMS

Installation & Operating Instructions

Disabled Persons Toilet Alarm Kit

EVCS EMERGENCY VOICE COMMUNICATION SYSTEMS

Channel Orbital Refuge

User Operation Guide Document: VI49.2

Folknoll Group Ltd. DISABLED REFUGE EVC BS :2011COMPLIANT TOUGH, VANDAL RESISTANT IDEAL FOR PUBLIC USE

Fire detection and alarm

User Guide. HTM Nurse Call. In the event of requiring assistance, please contact your Installer/Supplier.

Intelligent Security & Fire Ltd

Silent Alert Fire Safe System

Finally, an affordable wireless call bell system for smaller facilities

New Silent Alert Fire Safe System

SilentMAlert. ClofieldMLimited. ProductMDataMSheetsM. PagingMSystem. Silent

LEAKSTOPPER RANGE Multizone water leak detection systems

Care2 EVC CARE 2 EMERGENCY VOICE COMMUNICATION RADIAL WIRED SYSTEM BENEFITS: FEATURES:

Intercall 600 and Intercall 700 Installation & Operation Guide Documentation Issue 4.3

LEAKSTOPPER 1 Single zone water leak detection system

Emergency Voice Communication System (EVCS) Consu ltant s Specific atio n CONTENTS

Excel-EN Conventional Fire Control Panel

Smoke Vent Control Panel PCB4 V4 Installation Manual

Quantec NURSE CALL. Nurse call system & dementia care from Channel Safety Systems

Fire detection and alarm system Installation instructions

NURSE CALL SYSTEM SPECIFICATION

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

A BRITISH MANUFACTURER

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 2800PPM. Merlin CO2 Monitor 2800ppm. American Gas Safety LLC 1

Intercall 600 & Intercall 700 Installation & Operation Guide Documentation Issue 4.25

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

5000 INSTALLATION GUIDE

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

Conventional & Twin-wire Fire System

C2 Compact Range Installation & Programming Manual

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

Fire Safety Management Plan. Qube 90, Whitfield Street, W1T 4EZ. Fire Safety Management Plan & Evacuation Procedures

Saxon Range 1-8 Zone Convertional Control Panels

EN54 Part 23 Made Easy CPD PRESENTED BY SIMON ADAMS GENT BY HONEYWELL

The EN54 Part 2 and 4 Fire System

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Charlotte Building, 17 Gresse Street, London W1T 1QL

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

Intelligent Security & Fire Ltd

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Analogue addressable devices

Control Panel User Guide

Temporary wireless battery operated fire system from Channel Safety Systems

FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income.

St. Vincent s Health System Page 1 of 6

FIRE ALARM SYSTEMS - UCL GENERAL INSTALLATION DESIGN GUIDANCE & EMPLOYERS REQUIREMENTS (Student Halls of Residences & Sleeping Accommodation)

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

Clofield Limited. Product Data Sheets. Paging System. Care Call. Preventative monitoring for homecare... Wireless alerting system for Carers

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

REPEATER FS5200R OPERATION MANUAL

Technical Specification

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Installation, Operating and Maintenance Manual

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS

Solution Ultima Series Operators Manual ISSUE 1.00

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

Intercall. in touch with care

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1

HG Home Guardian Advanced Home Energy, Safety and Security Management

Sita200plus. 200detectors. Single loop analogue addressable System

SMARTWALK DEMENTIA WANDERING SYSTEM

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

APPLICATION DATA SHEET

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Control Panel Engineering and Commissioning Instructions

USER MANUAL CEF AP28 CONTROL PANEL

Engineer Paging. Staff Paging. Deaf Alert.

Solution 880 Operators Manual. Issue 1.00

FM MEDICOL. Cableflow International Limited. The FLUSH MEDICOL (FM) Patient Care Services. Column has evolved from a market requirement for a

Catalogue. ActionpacEMSStandard. Electro Mechanical Control & Monitoring System.

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Oakdale Primary School Expansion Project Appendix C Elec Equipment Schedule

Door Release Power Supply

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Wireless security products

Nurse Call Systems & Emergency Call Systems. Overview of ANSI/UL 1069 and ANSI/UL 2560

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Mounting Plate ADA/HOSPITAL SIGNALING DEVICES 14-8 FEATURES. > Momentary switch push button > Stainless steel faceplate

APPLICATION DATA SHEET

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

LeakSafe. solutions. WaterSwitch2. Installation Instructions

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.

EMERGENCY LIGHT SERIES

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

Fire Signalling. Signalling Solutions

The EN54 Part 2 & 4 Fire System

Transcription:

Disabled persons toilet alarm kit from Cameo Systems

Toilet alarm kit The Hark Help and Assistance Response Kit is simple to install and provides peace of mind wherever an indication of 'assistance required' is called for. Meeting the BS Standard requirement for all disabled toilets to be fitted with an emergency toilet alarm. Available in kit solutions finished in white or stainless steel, to fit discreetly into any decor or environment. The unit benefits from a reassuring audible sound from within the reset unit which confirms that assistance is on the way in addition the unit has braille text. Features Only 3 points to install on a standard system, and can be simply linked and expanded to other systems Simple to expand as requirements increase Sounder within the reset unit to give audible reassurance that assistance is on the way Kits supplied with Twin pull cord rings, Braille text on the reset unit as well as a Disabled Persons sticker Multi-way remote indicator units available Assists in compliance with the DDA, BS8300 & other care standards Suitable for commercial and public buildings as well as specialist areas such as hospitals, restaurants, nursing and retirement homes. HARK includes a variety of different accessories to work in compliance for a professional end result. These accessories combine modern aesthetics and high functionality providing you with the ideal solution for the most demanding installations. HARK assists with compliance with the DDA, BS8300 & other care standards Approved Document M- Access to & use of Buildings states the following: Pull cords for emergency alarms are coloured red, located as close to a wall as possible, and have two red 50mm bangles, one set 100mm and the other set between 800 & 1000mm above the floor. These should be reachable from the WC... Simple push buttons (reset unit) are not set more than 1200mm above the floor. This should be reachable from the WC. The emergency assistance signal (Lamp/sounder) is located so that it can be easily seen & heard by those able to give assistance. Help Alarm Response Kit The HARK! Help and Response Kit, disabled Toilet alarm comes in a kit solution that meets the BS standard requirement for all disabled toilets to be fitted with an emergency toilet alarm. Our system provides a simple to install, compliant, reliable and easy to use solution. Features Sounder within the reset unit to give audible reassurance that assistance is on the way Braille text on the reset unit Only 3 points to install on a standard system Can be simply linked to other systems Assists in ensuring compliance with the DDA, BS8300 & other care standards Simple to expand Multi-way remote indicator units available Twin pull cord rings supplied Disabled Persons sticker supplied CSHK1 Complete kit with pull cord, reset, PSU/Indicator 2 revision 013-1 www.cameosystems.co.uk ( 01202 892088 @ sales@cameosystems.co.uk

Help Alarm Response Kit + The HARK+ Help and Response Kit, disabled Toilet alarm comes in a kit solution that meets the BS standard requirement for all disabled toilets to be fitted with an emergency toilet alarm. The HARK+ comes with battery back up as standard. Features Brushed stainless steel Sounder within the reset unit to give audible reassurance that assistance is on the way Braille text on the reset unit Assists in ensuring compliance with the DDA, BS8300 & other care standards Multi-way remote indicator units available Twin pull cord rings supplied Our system provides a simple to install, compliant, reliable and easy to use solution. Only 3 points to install on a standard system Can be simply linked to other systems Disabled Persons sticker supplied Flush mounted CSHK1/SS Stainless steel option complete with battery back up (battery included) Push Button The HARK Push Button can be used instead of a hanging pull cord to notify that the user is in distress. Available in white polycarbonate or a stainless steel finish. CSHK1/PB CSHK1/PB/SS HARK 1 push button (White polycarbonate finish) HARK 1 push button (Stainless Steel finish) 3 revision 013-1 www.cameosystems.co.uk ( 01202 892088 @ sales@cameosystems.co.uk

Pull Cord Units The pull cord unit is supplied with a red plastic ring. An extra ring is supplied to conform to Approved Document M. The second ring should be fitted lower down near floor level. Activating a call is simply made by pulling the cord. This will activate the re-assurance indicator on the pull cord unit. In turn this will also illuminate the reset unit and trigger the internal sounder. At the same time the Over-door indicator/sounder unit will illuminate and trigger it s own internal sounder. Available white polycarbonate or stainless steel finish. CSHK1/PC CSHK1/PC/SS HARK 1 pull cord (White polycarbonate finish) HARK pull cord (Stainless Steel finish) Indicator Units The Over-door indicator/sounder unit is supplied with an integral Power supply unit. A fused spur should be fitted nearby and wired to this unit to provide power. The unit will illuminate and sound as soon as a call is activated. The unit will cease once the reset switch is pressed. Please note stainless steel version to be flush mounted. 75mm product 35mm 161mm CSHK1/PSU CSHK1/PSU/SS HARK 1 power supply unit HARK power supply unit stainless steel complete with battery back up 4 revision 013-1 www.cameosystems.co.uk ( 01202 892088 @ sales@cameosystems.co.uk

Reset Unit The reset unit has a blue engraved legend RESET. When a call is activated the reset switch illuminates and the internal sounder activates. The call is reset by simply pressing the reset switch. The reset switch is supplied with Braille legend on the switch piece. Available white polycarbonate or stainless steel finish. RESET CSHK1/RS CSHK1/RS/SS HARK 1 reset unit HARK reset unit stainless steel Indicator Units The Indicator Units are simple to install and meet the BS requirement for all disabled toilets to be fitted with an emergency toilet alarm. Measure to 148mm(W) 90mm(H) 57mm(D) These units can be purchased as either 1 or up to 10 indicators and come finished in either White Polycarbonate or Stainless Steel. Custom engraving is available, please send your enquiry to sales@cameosystems.co.uk CSHK1/RI/1 CSHK1/RI/1/SS CSHK1/RI/2 CSHK1/2/SS CSHK1/RI/4 CSHK1/RI/4/SS CSHK1/RI/6 CSHK1/RI/6SS CSHK1/RI/8 CSHK1/RI/8/SS CSHK1/RI/10 CSHK1/RI/10/SS HARK 1-way indicator unit white plastic HARK 1-way indicator unit stainless steel HARK 2-way indicator unit white plastic HARK 2-way indicator unit stainless steel HARK 4-way indicator unit white plastic HARK 4-way indicator unit stainless steel HARK 6-way indicator unit white plastic HARK 6-way indicator unit stainless steel HARK 8-way indicator unit white plastic HARK 8-way indicator unit stainless steel HARK 10-way indicator unit white plastic HARK 10-way indicator unit stainless steel 5 revision 013-1 www.cameosystems.co.uk ( 01202 892088 @ sales@cameosystems.co.uk

Operation Once the pull cord(s) are activated the reassurance LED on the pull cord will illuminate, the reset unit will illuminate & operate its internal sounder and the external lamp/sounder unit will operate along with any optional equipment installed. Simply pressing the illuminated reset switch will return the system to the normal' state. The pull cord, coloured red for high-visibility, has two rings that should be positioned in specific locations: - one should be only 100mm from the floor and the other should be at a height of 800-1000mm, reachable from the WC. The reset button, which has a sounder to indicate to the disabled person that assistance is on the way, should also be located within reach of the WC, at 1200mm from the floor. Ceiling Pull Cord 3 Core 4 Core Reset/Sounder to be 1200mm max above floor. PSU & Lamp/Sounder 230v AC The emergency assistance indicator should be installed in a highly visible location outside the rest-room where it will be easily seen and the sounder will be easily heard. Installing this stainless steel disabled toilet alarm system helps property and business owners to meet compliance with the DDA, BS8300 and various other care standards. 1 st Ring to be 100mm from floor. 2 nd Ring to be between 800/1000mm from floor. Equipment positioning with disabled persons facilities. Wiring Diagram Power Supply incorporating Lamp/Sounder X2 X1 0v X2 X1 0v X1 X1 X1 0v 0v 0v E L N 0v Reset Unit Pull Cord Unit 230v AC To additional equipment including remote indicators (CSHK1/RI/?) or disabled refuge outstation (RCO/GB or RCO/SS) To next pull cord Additional Options The Help Alarm Response Kit can be linked to a remote multi-way indicator panel (for use in a reception or staffed area). A 12 volt relay unit can be used to interface the unit to a wide range of equipment such as. Disabled Refuge Unit BMS Fire alarms Intruder Alarms Paging transmitters Additional pull cord units can be added to the system to allow for larger rooms or multi- area coverage. Please note that additional pull cords will operate and be reset by the same unit as the initial pull cord. 6 revision 013-1 www.cameosystems.co.uk ( 01202 892088 @ sales@cameosystems.co.uk