Instructions for Use. A-dec 461 Cuspidor with Support Center

Similar documents
InstructIons for use A-dec 561 Cuspidor

A-dec 300 Support Systems

Instructions for Use A-dec Self-Contained Water System

Preference ICC. Sterilization Center

Performer Cuspidor. Installation Instructions. (For Performer III Chair & International Performer I Chair) You Will Need. About This Install

Instructions for Use A-dec Inspire Dental Furniture

reference ICC A complete system for efficient sterilization

Regulatory Information and Specifications

Preference Productivity refined

Procenter Delivery Systems. [Includes: Delivery Units and Assistant s Units (All Styles)] (no serial numbers on Assistant s Units)

PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA USA [215] / FAX [215]

Use and Care Guide. Over the Patient Units and Swing Mount Units

Dental Unit User's Guide

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Installation Operation Maintenance Troubleshooting Version Dec/17. Mobile Cabinets

WL User Manual. Innovative Technology for a Connected World. global solutions: local support TM

PREFERENCE ICC. A Complete System For Efficient Sterilization

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-10 AseptiMini Pneumatic Portable Dental System

INSTALLATION INSTRUCTIONS

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-20B CompriCart

Manual No: Revision: E. Groundwater Sensor. Installation Guide

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Manual No: Revision: C. Overfill Alarm. Installation Guide

OPERATING INSTRUCTIONS

PLUMBING CODE REFERENCE Second Edition

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

MEGATRON MODEL 2, 3, 4, and 5

High Output Vacuum/Pressure Pump

INSTALLATION ADJUSTMENT SERVICE

TA-300, TA-300-LF, TA-350, TA-350-LF

X99 Series. Dental Handpiece. Instruction For Use

A-dec Inspire. Dental Furniture Collection

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

Keysight 85025/85026 Detector Exchange Program - All Serial Numbers

IWATA STUDIO SERIES MAXX JET AIR COMPRESSOR IS-1000

Artizan Ortho-Pedo Bench Installation / User Manual

CARE AND USE GUIDE VACUUM INSULATED HYDRATION BOTTLE

Site Requirements. MODEL 2.0 Australia

INSTALLATION INSTRUCTIONS

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-17X2 Express Plus II Portable Dental System

Instructions for use. 301 plus

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

Control Panel For Water Wash Hoods AM2

VARIABLE RATE INFUSION PUMP

OPERATION AND MAINTENANCE MANUAL

OPERATING INSTRUCTIONS

Manual No: Revision: D. Sump Sensor. Installation Guide

CER-1 & CER-2 Installation & Testing Instructions

INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE

OPERATING INSTRUCTIONS

AUTOTROL 363TC AUTOMATIC FILTER VALVE SERVICE MANUAL

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

CLASSIC. SIDE CABINET Installation Instructions

USER MANUAL. Soho All-In-One Chair Rev A 4/23/18. *shown with optional accessories and/or finishes. Earthlite 2018, All Rights Reserved

Hg5 Amalgam Separator Installation and Operations Manual

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

EEWH302A / EEWH304A PARTS REFERENCE

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-17A Express Air Portable Dental System

Model TG 1000 External Toilet Water Shut-Off Valve User Manual

User Manual. Hot Water Dispenser. Models: 177HWD15G 12/2018. Please read and keep these instructions. Indoor use only.

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12 Task Force Pneumatic Portable Dental System

Protégé Eclipse LED Keypad User Manual PRT-KLES

Operating Manual for Profident / Profident PLUS

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

Agilent N4011A MIMO/Multi-port Adapter

Short instructions for use ESTETICA E30

INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE

PAT LOAD MOMENT INDICATOR DS 150 / 0038

1.6 GALLON ONE PIECE TOILET

safety & regulatory information

Sloan AQUS Installation Instruction, Operation, and Maintenance Guide

B 353 COFFEE BREWING MACHINES MACHINES A CAFE KAFFEEBRUEHMASCHINEN KOFFIEZETAPPARATEN

CONTACTING CONDUCTIVITY BOILER SENSORS Instruction Manual

USER S OPERATING AND INSTRUCTION MANUAL

5000 Series Bottled Water System by.

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

MP-MBA-45T-1/60T-1 / 75T-1

Environmental Monitoring SmartSlot Card

Installation & Operation Manual

Installation Instructions Manual No: Revision F

Owner s Manual. Pelican Custom Premium WHWF 1354/1665

Vacu-Mixer. Operating Instructions

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder

User s Guide Home Automation Wall Socket for IWATCHALARM (Add-On) Model: SM-001SK

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

Short instructions for use ESTETICA E30

Transcription:

Instructions for Use A-dec 461 Cuspidor with Support Center

A-dec 461 Cuspidor with Support Center Instructions for Use Copyright 2014 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. A-dec Inc. shall not be held liable for any errors contained herein or any consequential or other damages concerning the furnishing, performance or use of this material. The information in this document is subject to change without notice. If you find any problems in the documentation, please report them to us in writing. A-dec Inc. does not warrant that this document is error-free. No part of this document may be copied, reproduced, altered, or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or by any information storage and retrieval system, without prior written permission from A-dec Inc. Regulatory Information Regulatory information mandated by agency requirements is provided in the Regulatory Information, Specifications, and Warranty document (p/n 86.0221.00), which is available in the Document Library at www.a dec.com. Product Service Product service is available through your local authorized A-dec dealer. For service information, or to locate an authorized dealer, contact A-dec at 1.800.547.1883 in the USA and Canada or 1.503.538.7478 worldwide, or visit www.a-dec.com. Trademarks and Additional Intellectual Property Rights A-dec, the A-dec logo, A-dec 500, A-dec 300, Cascade, Cascade Master Series, Century Plus, Continental, Decade, ICX, ICV, Performer, Preference, Preference Collection, Preference ICC, and Radius are trademarks of A-dec Inc. and are registered in the United States and other countries. A-dec 400, A-dec 200, Preference Slimline, and reliablecreativesolutions are also trademarks of A-dec Inc. None of the trademarks or trade names in this document may be reproduced, copied, or manipulated in any manner without the express, written approval of the trademark owner. Certain touchpad symbols are proprietary to A-dec Inc. Any use of these symbols, in whole or in part, without the express written consent of A-dec Inc., is strictly prohibited.

Content Map Bowl Rinse...2 Cupfill...2 Bowl Cleaning...4 Cuspidor Controls...2 Water Bottle...5 Flow Adjustment...3 Operate / Adjust... 2 Clean / Maintain... 4 Specifications and Warranty... 7 86.0374.00 Rev B 1

A-dec 461 Cuspidor with Support Center Instructions for Use Operate / Adjust Operate / Adjust Cuspidor Functions Bowl Rinse Spout Cupfill Spout Bowl Rinse and Cupfill Use the buttons under the cupfill spout or on the touchpad to control the bowl rinse and cupfill functions. The buttons support both programmed and manual operation. Button Description and Factory Presets Bowl Rinse Button Cupfill Button or Bowl Rinse Operation: Press and release the bowl rinse button for a timed operation. The factory preset is a 30 second rinse. Press and release the bowl rinse button twice in less than two seconds to activate the continuous operation mode. Press and release the button again to end the continuous mode. Press and hold the bowl rinse button for manual operation. Bowl Rinse Button Cupfill Button or Cupfill Operation: Press and release the cupfill button for a timed operation. The factory preset is a 2.5 second fill. Press and hold the cupfill button for manual operation. Note: Touchpad symbols are proprietary to A-dec Inc. For complete instructions on delivery system touchpad operation, see your delivery system Instructions For Use. 2

Touchpad Press and Hold Program Button Cupfill Spout Customize Bowl Rinse or Cupfill Timing To reprogram the timed bowl rinse or cupfill functions: 1. Press on the touchpad, or press and hold the cupfill and bowl rinse buttons under the cupfill spout. Release the button(s) when you hear one beep. 2. Within five seconds, press and hold the cupfill or bowl rinse button for the desired time. 3. Release the button. Three beeps confirm that the program has changed. Bowl Rinse Flow Adjustment 2 3 Cuspidor Stop Switch If an object gets caught under the cuspidor bowl as the chair is lowered, a stop switch will interrupt the chair motion to prevent damage. If the object becomes lodged, press Base Up ( ) on the footswitch or touchpad to remove the object and resume normal operation. See your dental chair Instructions for Use. The bowl rinse function should provide enough water to completely rinse the cuspidor bowl. If the flow is not sufficient, an adjustment can be made inside the support center: 1. Remove the side cover from the support center by pulling the lower edges of the cover out. 2. With the bowl rinse on, squeeze the pinch valve to reduce the flow. Release the valve to increase the flow. 3. For the best rinsing action, adjust the flow pattern by rotating the bowl rinse spout. 1 86.0374.00 Rev B 3

A-dec 461 Cuspidor with Support Center Instructions for Use Clean / Maintain Clean / Maintain Cuspidor and Drain Spouts and Bowl The contoured spouts and smooth bowl of the cuspidor provide for quick and easy cleaning. Remember to empty and clean the bowl screen every time you clean the cuspidor. CAUTION Do not remove the spouts when cleaning the cuspidor. This will help prevent cleaning solutions from damaging the equipment and contaminating the cupfill water. CAUTION Do not empty the solids collector screen or bowl screen into the cuspidor. Doing so could plug the cuspidor drain. Dispose of the contents in an appropriate biohazard container according to the regulations specific to your location. After cleaning, always install the bowl screen in the cuspidor bowl to prevent debris from plugging the drain. Gravity Drain Tubing At the end of each day, flush the cuspidor to remove debris from the flexible drain tubing. If the cuspidor is not flushed regularly, debris may build up and impair draining. To flush the cuspidor, run the bowl rinse for about 60 seconds. Maintenance Parts For replacement cuspidor bowl screens, order p/n 75.0035.03. Bowl Screen 4

Barrier Protection DANGER If you use barriers, always replace the barrier film after each patient. A-dec recommends barrier protection for all applicable touch and transfer surfaces. Touch surfaces are areas that come into contact with hands and become potential cross-contamination points during dental procedures. Transfer surfaces are areas that come into contact with instruments and other inanimate objects. In the USA, barriers must be produced under the Current Good Manufacturing Practice (CGMP) as specified by the U.S. Food and Drug Administration (USFDA). For regions outside the USA, refer to the medical device regulations specific to your location. IMPORTANT For recommendations on cleaning and chemical disinfection of touch and transfer surfaces (where barrier protection is not applicable or when barriers are compromised), please see the A-dec Equipment Asepsis Guide (p/n 85.0696.00). Self-Contained Water System The self-contained water system includes a 2-liter, quick-disconnect water bottle that mounts to the delivery system arm or support center and supplies water to instruments and the cuspidor cupfill. It also provides an easy way to control the quality of your treatment water. To properly maintain your system and water quality, A-dec recommends that you use an A-dec ICX tablet with every water bottle refill. Delivery Arm Support Center IMPORTANT Follow the instructions that appear on the ICX packaging. For complete details on water usage in your A-dec system, see the A-dec Self-Contained Water System Instructions For Use (p/n 86.0609.00) and Waterline Maintenance Guide (p/n 85.0983.00). 86.0374.00 Rev B 5

A-dec 461 Cuspidor with Support Center Instructions for Use Clean / Maintain Utilities and Shutoff Valves Air Manual Shutoff Valve Vacuum Line Water Manual Shutoff Valve Drain CAUTION When removing or replacing covers, take care not to damage any wiring or tubing. Verify that the covers are secure after replacing them. Filter Housing O-Ring Pre-Regulator Assembly Filter Beveled Edge Manual Shutoff Valve The utilities for A-dec chair-mounted delivery systems are located in the contoured floor box under your chair. To access, lift the cover up and off the floor box frame. The manual shutoff valves control the air and water to the system. To prevent leaks, leave these valves fully open (turned counterclockwise), except when your system is being serviced. Air and water pass through separate filters before entering the regulators. Replace these filters when they become clogged and restrict flow. To check for a clogged water filter: 1. Turn on the master toggle. 2. While watching the cuspidor, press the bowl rinse button. If the bowl rinse water pressure fades or if the water flow stops, replace the water filter. To replace the filter: 1. Turn off the master toggle and close the shutoff valves (turn clockwise). 2. Bleed the system of air and water pressure by operating the syringe buttons until air and water no longer flow. 3. Using a standard screwdriver, remove the filter housing from the water pre-regulator assembly and remove the filter. 4. Replace the filter if it is clogged or discolored. Install the filter with the beveled edge facing the manifold. CAUTION To ensure proper operation, install the filter with the beveled edge facing the manifold. 5. Open the shutoff valves, turn on the master toggle, and operate the bowl rinse to remove air from the waterline. 6

Specifications Warranty Warranty information is provided in the Regulatory Information, Specifications, and Warranty document (p/n 86.0221.00), which is available in the Document Library at www.a-dec.com. Minimum Air and Water Service Requirements Air: 70.80 L/min (2.50 scfm) at 551 kpa (80 psi) Water: 5.68 L/min (1.50 gpm) at 276 kpa (40 psi) IMPORTANT For electrical specifications, identification of symbols, and other regulatory requirements, see the Regulatory Information, Specifications, and Warranty document (p/n 86.0221.00), which is available in the Document Library at www.a-dec.com. NOTE Specifications are subject to change without notice. Requirements may vary depending on your location. For more information, contact your authorized A-dec dealer. 86.0374.00 Rev B 7

A-dec Headquarters 2601 Crestview Drive Newberg, Oregon 97132 United States Tel: 1.800.547.1883 within USA/CAN Tel: +1.503.538.7478 outside USA/CAN Fax: 1.503.538.0276 www.a-dec.com A-dec Australia Unit 8 5-9 Ricketty Street Mascot, NSW 2020 Australia Tel: 1.800.225.010 within AUS Tel: +61.(0).2.8332.4000 outside AUS A-dec China A-dec (Hangzhou) Dental Equipment Co., Ltd. 528 Shunfeng Road Qianjiang Economic Development Zone Hangzhou 311106 Zheijiang, China Tel: +1.503.538.7478 A-dec United Kingdom EU Authorized Representative Austin House, 11 Liberty Way Nuneaton, Warwickshire CV11 6RZ England Tel: 0800.ADEC.UK (2332.85) within UK Tel: +44.(0).24.7635.0901 outside UK ÍvÈ.Ç#jÈ.00CÎ 86.0374.00 Rev B Copyright 2014 A-dec Inc. All rights reserved. IFUlsbk3