VariCool EZ-Fit. Unique Solutions for All-Indoor HVAC Projects

Similar documents
VariCool EZ-Fit 12 to 70 Tons Variable Air Volume Water-Cooled Water Source Heat Pump Chilled Water

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

CoolSpot. Unique Solutions for All-Indoor HVAC Projects

MiniCool Ductless Split A/C Systems 1 9 Tons Single or Multi-Compressor Circuits Air-Cooled, Water-Cooled, and Chilled Water

VertiCool Space Saver 2 to 15 Tons Water-Cooled and Chilled Water Air-Cooled w/remote Condenser

C-Series. Unique Solutions for All-Indoor HVAC Projects

C13-Series. Unique Solutions for All-Indoor HVAC Projects

VariCool VAV Engineering Guide

OmegaAir. 100% Dedicated Outside Air System (DOAS)

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

CoolSpot Engineering Guide

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

Modular Indoor Systems For Effective Environmental Control

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

The ultimate fresh air solution.

62DA,DB,DC,DD,DE,DF07-38

THE ULTIMATE ROOFTOP SOLUTION

RoofPak Applied Rooftop Systems

Flexible & Innovative. Cooling Solutions

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Cultivator & Hybrid Cultivator

Energy Recovery with Cooling and Heating Model ERCH

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

C13-Series Engineering Guide

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

The Centurion Rooftop GAS/ELECTRIC, TONS ELECTRIC/ELECTRIC, TONS

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

VertiCool Aurora Engineering Guide

Water-cooled chillers with High Speed Centrifugal Compressors

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

Mammoth Water Source Heat Pumps

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Vision and Skyline Semi-custom Air Handlers

AHU ENERGY RECOVERY VENTILATORS ERV DEDICATED OUTDOOR AIR SYSTEMS DOAS HEATING, COOLING & DEHUMIDIFICATION AHU

208/230V, 1-Phase. 208/230V, 460V 3-Phase. 208/230V, 460V 3-Phase

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Submittal Summary Page

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

TRIDENT GS SERIES Central Chiller

PR SERIES SELECTION AND OPTIMIZATION GUIDE

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

PERFECT SOLUTIONS WATERFURNACE COMMERCIAL PRODUCTS. Water Source/Geothermal Heat Pumps

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

Maverick II Commercial Rooftop Systems 15 to 75 tons

NQ Series Portable Chillers

System Floor Mount Systems DX / Glycol / Chilled Water 6-12 Tons. High Density Presicion Cooling. Kompact.

Engineered for flexibility and performance

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

TECHNOLOGY GUIDE. :: the dawn of a new era in commercial HVAC technology. The all-new Rheem Commercial Renaissance Line featuring:

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

ALL PRODUCTS BROCHURE

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

CONDENSERS AND CONDENSING UNITS

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

1.1 This section applies to air handling units for HVAC Systems.

A Career that will take you to heights you never imagined!

COMMERCIAL PRODUCT LINE

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

THE RIGHT SPEC. RIGHT NOW.

Direct Gas-Fired Make-Up Air Models DG and DGX

Product Line Card. Daikin Applied HVAC system solutions. Advanced technology and solutions from the world s leading innovator in HVAC.

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

Marvel J MICROPROCESSOR CONTROLLER

OACS Outdoor Air-Cooled Central Chillers

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Liebert Mini-Mate2 1 To 8 Tons

LQ AQ SQ. Air-cooled and water-cooled portable chillers

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

LQ AQ SQ. Air-cooled and water-cooled portable chillers

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

HVAC 101. H V A C S y s t e m s

Liebert Mini-Mate2 1 To 8 Tons

Operation & Maintenance Manual

Seresco Indoor Pool Dehumidifiers. Unrivaled Performance, Reliability and Value

GP SERIES Packaged Chillers

Trailblazer air cooled scroll chillers

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Transcription:

VariCool EZ-Fit 12 to 90 Tons Variable Air Volume Water-Cooled Water Source Heat Pump Chilled Water DOAS (Dedicated Outdoor Air System) Air-Cooled with Remote Condenser Unique Solutions for All-Indoor HVAC Projects

VariCool EZ-Fit Water-Cooled Chilled Water Modular Floor-by-Floor Air Conditioning Systems The VariCool EZ-Fit is a self-contained, modular air conditioning system for use with floor-by-floor variable air volume applications. It is engineered and manufactured specifically for installation in renovation and retrofit projects and provides the ultimate All-Indoor Solution for challenging HVAC applications. The VariCool EZ-Fit design consists of three distinct sections that easily mate to form a system module. The module consists of a fan section, evaporator coil section and condensing section. Single modules are available in 12-15 ton, 20-25 ton, 30-35 ton and 40 45 ton sizes. Dual modules together form systems as large as 90 tons of cooling. Sections are assembled during manufacturing and evacuated, charged, tested, and then separated for shipment of individual sections. The use of resealable refrigerant fittings allow the unit to be shipped split without losing the charge. All module sections are joined together using innovative 3D-Intelliclamp connectors which ensure perfect component alignment. The result is a lower installed cost without any sacrifice of system reliability. Fits Through Doorways, Narrow Hallways & Elevators! FEATURES 12 to 90 tons Water-Cooled Chilled Water Dual Scroll Compressors/Module Interlaced Evaporator Coils Premium Efficiency Motors Double Sloped Stainless Steel Drain Pan Hot Gas Bypass (each circuit) Lift Off Hinged Panels Belt Drive Airfoil DWDI Blower with Backward Inclined Blades (12-25 Ton Modules) Direct-Drive Parallel Fans (30-35 & 40-45 Ton Modules) Factory Mounted VFD Controllers Microprocessor Control 3D-Intelliclamp Cabinet Section Connectors Individual sections fit through standard 3-0 doors or smaller and into most elevators. They can also be maneuvered down narrow hallways which means no modifications or alterations to the building are needed and installation time is quicker and less costly to accomplish. As with all United CoolAir systems, a wide variety of features are standard and a host of options allow every system to be tailored to the specific project at hand. 2

Total Installed Cost Advantages Avoid Requirements that Lead to Extra Expense Expensive Equipment, Rigging or Permits Equipment can be shipped in sections Fits easily through standard doors, hallways, and into elevators Minimizes the need for crane rentals, rigging crews, and municipal permits Roofcurbs or Roof Penetration Eliminates expensive curb equipment cost Reduces installation labor Eliminates possible roof water damage Field Piping, Brazing, Evacuation or Charging Factory charged and utilizes Resealable Refrigerant Fittings Reduces installation labor Faster installation and commissioning Excessive Downtime when Replacing Old Systems Sectional shipments accelerate installation Can be installed off-hours and on weekends Shipment can be made to coincide with installation schedules Equipment Damage Due to Weather All equipment is installed indoors Avoids premature replacement costs due to weather wear and/or damage Eliminates downtime due to severe storms Possibility of Theft or Vandalism Eliminates expensive repairs and replacements due to theft and vandalism Enhances building security by eliminating interruption to service Eliminates extra cost for cages and special alarms Field Testing of Installed Product Minimizes field testing as units are functionally tested prior to shipment Reduces labor and speeds installation Assures trouble-free start-ups Outdoor Servicing of Product Outdoor/premium service expense in extreme weather completely eliminated Improves reliability Eliminates roof safety issues Architectural Damage to Building Eliminates expenses for code approvals Requires no rigging holes through building walls Minimizes any type of building alteration Compromise in Performance With Built-to- Order Design Units are built to exact requirements Avoids purchase of excess capacity from standard product offerings Extensive list of configurations and options Major Ductwork or Electrical Modifications Units ordered to closely match existing duct and utility locations Major installation, labor and time savings Exterior Condensing System Eliminates rooftop and pad installation space and cost Water-Cooled and Chilled Water configurations eliminate unsightly equipment outdoors Resealable Refrigerant Fittings Most models feature Resealable Refrigerant Fittings. Unit sections can be shipped split or split in the field without losing the factory charge resulting in no field brazing and a total installed cost advantage. 3

VariCool EZ-Fit Ideal for Renovation and Replacement Projects The basic VariCool EZ-Fit modular design and standard features provide the ideal retrofit and replacement design for many projects. However, it does not always provide the ideal product solution and that is why United CoolAir offers an extensive list of options to further match each VariCool EZ-Fit unit to the specific application requirements. These options are designed to optimize performance while minimizing installation complexity, time and expense. POPULAR OPTIONS More than 25 cabinet sizes available ECM Fans Variable Speed Compressor BMS Interface High Efficiency Filters Double Wall Construction Water Side Economizer Hot Water, Steam, or Electric Heat Lead Circuit Digital Scroll Compressors Internally Isolated DDP Fan Systems Direct Drive Parallel Fan Systems Painted Cabinets TYPICAL APPLICATIONS Healthcare Facilities Universities/Schools High Rise Buildings Office Buildings Commercial/Retail Centers Laboratories Lobbies Conference Rooms Churches 4

VariCool EZ-Fit BMS Your Choice for Building Management System Interface Options The VariCool EZ-Fit system is designed to operate using the full-featured Marvel Plus microprocessor control system. The Marvel Plus control system incorporates a Marvel Plus Microprocessor Control and a Marvel Plus Wall Mount display. The power of the Marvel Plus control system can be put to good use through integration with an existing Building Management System. The system is compatible with most protocols including BACnet over MS/TP (RS485 Serial), BACnet over IP (Ethernet/EIA485), ModBus RS485 Serial Connection, ModBus TCP over IP, Lon- Works FTT10 (RS485 Serial), or other systems using a Serial interface card. A large number of analog and digital inputs and outputs come standard which allows most single and multiple-unit projects to control and communicate the most important aspects of operation and alarm status. In addition, up to 16 controllers can be networked to a single wall display. IoT allows for remote connectivity to provide support from United CoolAir. Single Dual Marvel Plus Microprocessor Control System in unit Marvel Plus Wall Display WATER-COOLED PERFORMANCE DATA Nominal Tons Total MBH Sensible MBH CFM GPM 12 165.8 117.1 4800 36 15 202.0 143.5 6000 45 20 260.2 187.7 8000 60 25 300.9 213.0 9000 72 30 382.2 283.5 12000 90 35 451.6 330.7 14000 105 40 480.1 364.5 15000 120 45 600.2 415.6 15000 136 24 331.6 234.2 9600 72 30 404.0 287.0 12000 90 40 520.4 375.4 16000 120 50 601.8 426.0 18000 144 60 764.4 567.0 24000 180 70 903.2 661.4 28000 210 80 960.2 729.0 30000 240 90 1200.4 831.2 30000 272 Contact the factory for Chilled Water and Water Source Heat Pump models 5

VariCool EZ-Fit EMBLEMHEALTH FACILITY Case Study MANHATTAN, NY EmblemHealth Chose the VariCool EZ-Fit System for a Successful Replacement Project United CoolAir was hired for a project at an EmblemHealth facility located in Manhattan, NY. The building was erected in the early 1970 s and the mechanical systems have been running for over 25 years. The air conditioning system had to be replaced quickly with the least amount of disruption to the patients, service providers and staff. T he EmblemHealth building had four existing units spread out from the basement, main floor and at an upper level. Sizes ranged up to 45 tons and the replacement units would need to be the same size. Many of the systems were installed during the building construction when access was not an issue. It is generally not a problem to remove the old air conditioning system because the units are disassembled and scrapped, but installing the new units can be tricky. This is where we came in to help. Our distributor, MWSK Equipment, was hired for this project and Fredi Taruc, Sales Engineer at MWSK, immediately thought of United CoolAir s VariCool EZ-Fit system as the best option for the replacement. The Dual-Module VariCool EZ-Fit unit that was installed Regardless of the entry method, the installation cost can easily exceed the equipment cost when you measure man hours, permits and special equipment necessary to complete the job. There s the additional time needed for demolition, installation and final commissioning. Often the HVAC contractor has to do a lot of preparation work in order to fit a system through small passageways. Larger units may have to be raised by crane to upper floors and require rigging, permits and building modification. If they take it through the building, the unit may have to be delivered partially disassemble and reassembled on site, or walls and doorways opened to allow access, said Taruc. EmbleHealth needed to get the replacement units in quickly and with as little building modification as possible. Unlike most commercial buildings, healthcare facilities are generally active 24 hours each day. The retrofit was scheduled for two weekends with two units replaced each weekend. John McBride, Design Left: Joe Ptak, Chief Engineer for Engineer for JFK EmblemHealth. Right: Fredi Taruc, & M Consulting Group made sure Sales Engineer at MWSK the replacement work would not interrupt the facility s busy weekend schedule. The old equipment was removed on a Friday and the replacement units were brought in with minimal interference with the hospital s operations. The modular sections were quickly reassembled and connected to the existing hookups. Since the units were pre-charged at the factory, brazing, evacuation and charging in the field were eliminated saving many hours of valuable labor. The units were operational by Monday morning at the start of the new week, said McBride. This came as no surprise to Joe Ptak, Chief Building Engineer for EmblemHealth, who was first introduced to United CoolAir air conditioning systems. The initial units were installed in his building and he has been very satisfied. I was very pleased with the performance of their units then and I recommend using United CoolAir systems for all the other EmblemHealth mechanical system replacements, said Ptak. Visit www.unitedcoolair.com or call the factory at 717-843-4311 for more information 6

Basic Model Designation EXAMPLE: VZ a W b R c 20 d G e 3 f A g T h A i A j 30 k - A l - X m a. VZ = VariCool EZ-Fit b. W, CW or A W = Water-Cooled CW = Chilled Water Air Handler A = Air Cooled w/ Remote Air Cooled Condenser c. R, L or D Module Quantity/ Style R = Right Hand Single Module L = Left Hand Single Module D = Dual Module d. 12, 15, 20, 25, 30, 35, 40 or 45 Nominal Cooling Capacity in Tons (Single Module) 24, 30, 40, 50, 60, 70, 80 or 90 Nominal Cooling Capacity in Tons (Dual Module) e. G Common to all f. 3, 4 or 5 Indicates Power Supply 3 = 208/230-3-60 4 = 460-3-60 5 = 575-3-60 g. AF, AD, ADF, AVF, AV, BF, BD, BDF, AVF, BV or Compressors Single Module Arrangement Dual Module Arrangement Dual/Module Arrangement Single/Dual Dual/Triple Circuit Four Circuit Circuit AF Two Fixed BF Three Fixed DF Four Fixed AD 2 Digital BD 3 Digital DD 1 Digital - 3 Fixed ADF 1 Digital - 1 fixed BDF 1 Digital - 2 fixed DDF 2 Digital - 2 fixed AVF 1 Variable Speed BVF 1 Variable Speed DVF 1 Variable Speed 1 Fixed 2 Fixed 3 Fixed AV 1 Variable Speed BV 2 Variable Speed DV 2 Variable 2 Fixed - = No Compressors / Chilled Water Unit h. T Traditional Cabinet C Custom Cabinet i. A or - Refrigerant A = R410a Refrigerant - = No Refrigerant / Chilled Water Unit j. A, B, C Blower Type A = DWDI Blower B = Parallel Direct Drive Fan C = ECM Fans k. Nominal Heat kw l. A, C R or S Evaporator Air Path m. X = Special Configuration EVAPORATOR AIR PATHS Blower Type Front Top (Standard) Rear Side DWDI Blower C A R NA Direct Drive Parallel Fans Not Available A R S ECM Fans C A R S Not all combinations of Basic Model Designations are valid. Check with the factory for correct model identification. 7

Unique Solutions for All-Indoor HVAC Projects VertiCool Classic Vertical, 3-30 Ton VertiCool Aurora Vertical, 3-35 Tons Portable Cooling and Heating Units 3-30 Tons Authorized Distributor: C13-Series Horizontal 2-10 Tons VariCool VAV, 9-70 Tons VariCool EZ-Fit VAV, 12-90 Tons C-Series Horizontal 1-15 Tons Special Configuration Engineered to Order Alpha Aire 100 500 CFM OmegaAir Horizontal and Vertical 100% Outside Air 150 3000 CFM LIMITED WARRANTY United CoolAir Units are backed by a 1 year limited warranty on parts and a 5 year limited warranty on the compressor (labor not included). Maintenance items such as filters and belts are excluded under this limited warranty. FACTORY TESTED All units are functionally run tested before shipment to ensure a trouble-free start-up and unit commissioning. Industry proven components are used throughout to enhance system reliability and peace of mind. Scan to learn more about all of our products! 491 East Princess Street, York, PA 17403 Phone: 717-843-4311 Fax: 717-854-4462 email: uca@unitedcoolair.com web: www.unitedcoolair.com Copyright by United CoolAir Corporation 2017. All rights reserved. Manufacturer reserves the right to make changes without notice. 40.20-SB (0917)