Installation Instructions Read and become familiar with these instructions before beginning installation.

Similar documents
Installation Instructions Read and become familiar with these instructions before beginning installation.

Installation Instructions

Installation Instructions

Installation Instructions

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

RG57F3(B)/BGEFU1 Wireless Remote Controller. Service Manual

Owner s Information Manual

Installation Instructions

TCB-IFTH1GUL. 24V Thermostat Interface. Installation Manual. Model name: English FOR INSTALLER

Installation Instructions

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS

Owner s Information Manual

Installation Instructions

Owner s Manual TABLE OF CONTENTS

Installation Instructions

Installation Instructions

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

Installation Instructions

Installation Instructions

Installation Instructions

Fig. 1 - Unit PGD4, PGS4, WPG4

Installation Instruction

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Installation Instructions

Installation and Owner s Manual

Service Manual CAUTION ! WARNING INTRODUCTION. 619PB High Wall Ductless System Sizes 09 to 36

Installation Instructions

Installation Instruction

Installation Instructions

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

Fig. 1 - Unit PHD4 and WPH4

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

Installation Instructions

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

Owner s Manual TABLE OF CONTENTS

Installation Instructions

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MA*R Outdoor Unit Single Zone Ductless System Sizes 09 to 36

INSTALLATION INSTRUCTIONS R 410A

Installation Instructions

DLCMRA. INSTALLATION INSTRUCTIONS Multi zone Outdoor Unit Ductless System Sizes 18, 27, 36 and 48 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

Installation Instructions

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

Installation Instructions

Owner s Manual TABLE OF CONTENTS

Owner s Manual TABLE OF CONTENTS

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

HEAT PUMP INSTALLATION MANUAL

Installation Instructions

Installation Instruction

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Installation Instructions Part No , Part No Part No

Installation Instructions

Owner s Manual Super-Slim Four-Way Cassette

Installation Instruction

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Owner's Guide to Operating and Maintaining Your Gas/Electric Unit

Installation and Owner s Manual

Installation Instructions

Installation Instructions

Installation Instructions

40KMC KMQ

KDIR TROUBLESHOOTING. Middle Static Pressure Duct Type SERIES

Installation Instructions

Installation Instructions

Installation, Start-Up, and Operating Instructions

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

Installation Instructions

Installation Instructions

Installation Instructions

KSD-35 DR11 KUE-35 DVN11

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

Ductless Split Air Conditioner

Ductless Split Air Conditioner

SERVICE MANUAL MATRIX 18.2 CU FT TOP MOUNT REFRIGERATOR

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Wired Controller XK60

Transcription:

KSAIC005 (5V) KSAIC00230 (208-230V) 24V Interface Kit for Ductless Systems Installation Instructions Read and become familiar with these instructions before beginning installation. SAFETY CSIDERATIS Read these instructions thoroughly and follow all warnings or cautions included in the literature and attached to the unit. Consult local building codes and National Electrical Code (NEC) for special requirements. Recognize safety information. This is the safety alert symbol!!. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand these signal words: DANGER, WARNING, and CAUTI. These words are used with the safety alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTI is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.! WARNING TABLE OF CTENTS SAFETY CSIDERATIS... OVERVIEW... DIMENSIS... 2 CLEARANCES... 2 INSTALLATI... 3 SYSTEM CFIGURATI SCENARIOS... 3 DIP SWITCHES CFIGURATI... 5 ERROR CODES... 6 COMPATIBILITY... 7 WIRING DIAGRAM... 8 OVERVIEW The 24V INTERFACE KIT is used to connect a SINGLE ZE Ductless System to a 3rd party single stage conventional thermostat. ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Before beginning any modification or installation of this kit, be sure the main electrical disconnect is in the OFF position. Ensure power is disconnected to the fan coil unit. On some systems both the fan coil and the outdoor unit may be on the same disconnect. Tag the disconnect switch with a suitable warning label. There may be more than one disconnect.! CAUTI EQUIPMENT DAMAGE HAZARD Failure to follow this warning may result in equipment damage. Do not install the wired controller in an area subjected to excessive steam, oil or sulfide gas. Doing so may cause the controller to deform and/or fail.! WARNING INSTALLATI Entrust the distributor or authorized professionals to install the unit. Installation by unskilled persons may lead to improper installation, electric shock, or fire. Re installation must be performed by authorized professionals. Non compliance may lead to electric shock or fire. NOTE: Images are for illustration purposes only. Actual models may be slightly different. Table Kit Contents: Confirm the following parts are included No. Description Qty Remarks Control box n/a 2 Installation Manual n/a 3 Screws 3 M4X20 (for wall mounting) 4 Wall anchors 3 For wall mounting 7 8 Return Air Thermistor Assembly 6.4ft. (5m) Return Air Thermistor Assembly Extension Wires Used on future applications Used on future applications Table 2 Field Supplied Components: Prepare the following assemblies on site No. Description Qty Type Remarks Switch Box n/a n/a 2 Wiring Tube (insulating sleeve and tightening screw) n/a n/a

! WARNING The wiring should adapt to the wire control current. Otherwise, electric leakage or overheating may occur and result in a fire. The specified cables shall be used in the wiring. No external force may be applied to the terminal. Otherwise, the wire may be damages and heating may occur and result in a fire.! CAUTI The shielded wire must be grounded. Sensor connecting cable should not be longer than 23in. (7m). The control box operates on low voltage circuit loops. DO NOT connect a 220V or 380V cable to the circuit loop. Ensure the configured tubes are 2 20in. (30 50cm) or more apart. DO NOT use a ohmmeter to detect the insulation after wiring the control box. DIMENSIS.3 (32mm) 8.7 (220mm) 0.6 (5mm) 7.8 (200mm) 6.9 (76mm). (283mm) 2.5 63mm Fig. 24V interface structure size CLEARANCES Table 3 24VAC Interface Clearance Dimensions Clearances Unit Minimum Value In (mm) Sides 3.5 (89) Front 24 (60)* Top and Bottom 3 (76.2) NOTE: *24 in (60mm) minimum for service access or use local code. 2

INSTALLATI Installation Location The 24V INTERFACE KIT is rated for outdoor and indoor mounting (depending on the application).! CAUTI DO NOT install the 24V INTERFACE KIT near flammable liquids or gases such as gasoline or hydrogen sulfide. Doing so creates a fire hazard.. Remove the cover of the 24V INTERFACE KIT. Remove the six screws of the 24V INTERFACE KIT with a screwdriver or similar tool. Rotate the lid along the hem to disassemble. Fig. 4 Cover the screw SYSTEM CFIGURATI SCENARIOS Scenario No. : Match the following ductless indoor units with the corresponding compatible SINGLE ZE outdoor units: High Wall (Sizes 9~36) Cassette (Sizes 9~8) Ducted (Sizes 9~24) Floor Console (Sizes 9~2). Fig. 2 Remove the Cover 2. Mount the 24V INTERFACE KIT horizontally (see Fig. 3), by fastening the back plate to the wall with 3 screws (M4x20) and anchors.! CAUTI The 24V Interface kit cover has a directional arrow on the cover. In case of outdoors installation verify, during the mounting process, that this arrow will point UP upon installation. Failure to mount the kit correctly can cause water ingress into the box which may compromise the electrical component integrity. Back plate Screws (M4 20) Indoor Unit Outdoor Unit Indoor Indoor Outdoor Outdoor L L2 S S S2 L L2 S S S2 24V AC Output R C 24V INTERFACE Y W G Aux/Dry T Fig. 5 Scenario -OFF Y Y2 W G W2 C R 24 VAC 70 Thermostat NOTE: On selected indoor units, the Up Down Swing Louver function as well as the control to turn off the indoor unit display is available on the unit s Wireless Remote controller.! CAUTI The indoor unit requires an updated control board for compatibility with the 24V interface. High Wall Indoor units starting with serial # 426V000 are shipped the compatible control board. Ducted Indoor units starting with serial # 466V000 are shipped the compatible control board. Indoor units with new control board are also marked with a blue sticker on the shipping label. Scenario No. 2: Match the following ductless indoor units with the corresponding compatible SINGLE ZE outdoor units: Ducted (Sizes 36~48). See the compatible units on Table 5. Fig. 3 24V Interface Kit NOTE: Place the unit in a flat surface. Be careful not to distort the back plate of the 24V INTERFACE KIT by over tightening the screws. 3. WIRING Based on the system used, wire the unit as shown on the System Configuration Scenarios Section. 4. Cover the 24V INTERFACE KIT Lid, and lock back in place using the six screws previously removed. Indoor Unit Outdoor Unit Indoor Indoor Outdoor Outdoor LL2 S S S2 L L2 S S S2 24V AC Output R C 24V INTERFACE Y W G Aux/Dry T Fig. 6 Scenario 2 -OFF Y Y2 W G W2 C R 24 VAC 70 Thermostat 3

! CAUTI The conventional thermostat must be configured for use with a single stage air conditioner (Y output LY) and a single stage heating (W) system. Control Logic Table 4 Conventional Thermostat Connections Connector Purpose R/C 24VAC Output Y Cooling W Heating G Fan-Auto Speed G/G2/G3 Fan Speed Low/Medium/High AUX/DRY Aux-Heat/Dry Table 5 Mode Setting Y W G G G2 G3 Aux/Dry Setting Mode X Cooling X X Heating (without aux-heater) X Heating (with aux-heater) X X X Fan only (Auto Fan Speed) X X X X Fan only (Low Fan Speed) X X X X X Fan only (Medium Fan Speed) X X X X X X Fan only (High Fan Speed) OFF X X X X X X X OFF X X DRY FAN SPEED Select Auto, Low Medium or High Airflow To provide airflow at the rates described in Tables 4 and 5, the Fan Speed input G (Auto), G (Low), G2 (Medium) or G3 (High) must be selected. Use the selection options provided to adjust the airflow supplied to meet the individual installation needs for such things as noise, comfort, and humidity removal. Table 6 Fan Speed Setting Unit /OFF G G G2 G3 Setting Fan Speed X X X X Auto Fan Speed Auto Fan Speed X Low Speed X X Medium Speed X X X High Speed X X X X X Fan OFF LEGEND X OFF or OFF 4

DIP SWITCHES CFIGURATI The 24V INTERFACE KIT must be configured to operate properly with the system components with which it is installed. To successfully configure the system, move the Dip Switches to match the components and functions used. Dip Switch 4 Dry is used for thermostats with a Dry Function output. An auxiliary heater is used on the Ducted Style Indoor Units (Scenario and 2) to control a secondary Heat Source. Table 0 Dip Switch 4 SW4 Result Note Dry OFF Aux Heater Default Dip Switch 5 Used to increase the compressor frequency in case the set point has not been reached after hour or 3 hours of operation. Fig. 7 DIP Switch Definitions Dip Switch Used for selection of the indoor unit type. Table 7 Dip Switch SW Result Note Sets - Both Ductless Indoor and Outdoor Units Default OFF Used on Future Applications Dip Switch 2 Used for selection of the system: Cooling Only or Heat Pump. Table 8 Dip Switch 2 SW2 Result Note Cooling Only OFF Heat Pump Default Table Dip Switch 5 SW5 Result Note h OFF 3h Default Dip Switch 8 Used to turn or OFF the diagnostic code display LED on the control board of the 24V Interface Kit. Table 2 Dip Switch 8 SW8 Result Note Display on Default OFF Display off NOTE: Dip Switches 6 and 7 not used. They are reserved for future applications. Dip Switch 3 Used for freeze protection of the indoor coil. Table 9 Dip Switch 3 SW3 Result Note Fan does not stop OFF Fan stops if the indoor coil temperature is low Default NOTE: Applicable only to Ductless Style Indoor (scenario and 2) Heat Pump units in the Heating Mode. 5

ERROR CODES For ease of service, the 24V Interface is equipped with a diagnostic code display LED on the control board. Table 3 Error Codes Display Malfunction and Protection Indication E0 Indoor EEPROM error E2 Cross-zero detection error E3 Indoor fan speed malfunction E4 Indoor room temperature sensor error E5 Evaporator coil temperature sensor error EC Refrigerant leak detection system malfunction F0 Current overload protection F Outdoor ambient temperature sensor (T4 ) malfunction F2 Condenser coil temperature sensor (T3) malfunction F3 Condenser coil temperature sensor (T5) malfunction F4 Outdoor unit EEPROM parameter error F5 Outdoor fan speed has been out of control F6 T2b sensor error P0 Inverter module (IPM) malfunction P Over-voltage or under-voltage protection P2 Compressor top high temperature protection (OLP) P3 Low ambient temperature cut off in heating P4 Compressor drive malfunction -- Mode conflict P6 Compressor low-pressure protection 00 Module boot mode and indoor running mode for power off IN Module and indoor unit communication malfunction OU Module and outdoor unit communication malfunction 6

COMPATIBILITY The 24V INTERFACE KIT is compatible with most thermostats matched with the Ductless Systems listed below. Before installation, check the compatibility of your Ductless System. Professional installation is recommended Table 4 Scenario Volt-Ph @ 60Hz Kit Number Indoor Model Number Outdoor Model Number 40MAQB09B-- 69PAQ009BBMA 38MAQB09R-- 40MAQB2B-- 69PAQ02BBMA 38MAQB2R-- 5 - KSAIC005 40MHHC09--- 38MHRC09A-- 40MHHC2--- 38MHRC2A-- 40MHHQ09--- 38MHRQ09A-- 40MHHQ2--- 38MHRQ2A-- 40MHHC09---3 38MHRC09A--3 40MHHC2---3 38MHRC2A--3 40MHHC8---3 38MHRC8A--3 High Wall 40MHHC24---3 38MHRC24A--3 40MHHQ09---3 38MHRQ09A--3 40MHHQ2---3 38MHRQ2A--3 208/230- KSAIC00230 40MHHQ8---3 38MHRQ8A--3 40MHHQ24---3 38MHRQ24A--3 40MAQB2B--3 69PEQ02BBMA 38MAQB2R--3 40MAQB8B--3 69PEQ08BBMA 38MAQB8R--3 40MAQB24B--3 69PEQ024BBMA 38MAQB24R--3 40MAQB30B--3 69PEQ030BBMA 38MAQB30R--3 40MAQB36B--3 69PEQ036BBMA 38MAQB36R--3 40MBCQ09---3 38MAQB09R--3 Cassette 208/230- KSAIC00230 40MBCQ2---3 38MAQB2R--3 40MBCQ8---3 38MAQB8R--3 40MBQB09D--3 69REQ009DBMA 38MAQB09R--3 Ducted Style 208/230- KSAIC00230 40MBQB2D--3 69REQ02DBMA 38MAQB2R--3 40MBDQ8---3 38MAQB8R--3 40MBDQ24---3 38MAQB24R--3 Floor Console 208/230- KSAIC00230 40MBFQ09---3 38MAQB09R--3 40MBFQ2---3 38MAQB2R--3 Table 5 Scenario 2 Volt-Ph @ 60Hz Kit Number Indoor Model Number Outdoor Model Number Ducted Style 208/230 - KSAIC00230 40MBDQ36---3 38MBRQ36A-- 3 40MBDQ48---3 38MBRQ48A-- 3 7

WIRING DIAGRAM Set/outdoor only SW Mode Outdoor only Set Unit type SW2 Mode Heat Cooling pump only Anti-cold SW3 Mode YES NO Aux-heat/dry SW4 Mode Auxheat Dry Frequency Time SW5 Mode 3H H Dis play tube SW8 Mode OFF To outdoor Comm.Bus (S)P Q(S2) E CN8 24V I NTE R FA CE M ODULE CN4 CN7 /OFF ALARM Remote Control Alarm Output To indoor Comm.Bus Aux-heat control signal NOTE : Connector R/C Y W G G/G2/G3 AUX/DRY (S)P Q(S2) DRY Aux/Dry CN9 CN5 R C 24V R 24V C CN8 CN9 G G2 G3 Y W G L_Fan M_Fan H_Fan 24V THE RMOSTAT Purpose 24VAC Output Cooling Heating Fan-Auto speed Fan Low/Middle/High Aux-Heat/Dry Cool Heat Auto_Fan CN23 BROWN BLUE CN2 RED BLACK BROWN BLUE BLACK CN BLACK 2 3 2 3 2 L L2 S 3 2 L L2 S 3 TO INDOOR TO OUTDOOR Fig. 8 24V Interface Wiring Diagram AC:220V/20V AC:24V CN CN2 CN6 CN7 TRANS CN6 CN5 WORK T This symbol indicates the element is optional,the actual shape shall prevail. 2 ROOM TEMP. SENSOR Work Output RED Copyright 207 CAC / BDP 730 W. Morris St. Indianapolis, IN 4623 Edition Date: 0/7 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 8 Catalog No: IM KSAIC0 0 Replaces: NEW