Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

Similar documents
Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

University of Houston Master Construction Specifications Insert Project Name SECTION DOMESTIC WATER HEATERS PART 1 - GENERAL

ASME Packaged Indirect Fired Water Heater

SECTION HEATING BOILERS

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

Packaged Steam Fired Water Heater

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

Packaged Semi-Instantaneous Steam Fired Water Heater

Semi-Instantaneous Indirect Fired Water Heater

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

Peerless Boilers. Series MI. Residential Gas Boilers

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

SECTION WATER-TUBE BOILERS

ASME Packaged Electric Water Heater

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

MAXIM. Power Combustion Storage Water Heater Gas, Oil or Combination Gas/Oil. 199 to 1200 MBH 125 and 250 Gallon Tanks 15-year Warranty. PVI.

THE HARD WATER WATER HEATER

High Efficiency Commercial Gas Water Heaters

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

Fuel-Fired Vertical Tubeless Boilers

FUEL-FIRED VERTICAL TUBELESS BOILERS

mith Mills 4500A Smith Mills 4500A 4500A-3R OIL, GAS OR COMBINATION GAS/OIL COMMERCIAL BOILER/BURNER CAST IRON

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

Originators of the Flexible Water Tube design

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

SECTION WATER HEATERS

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON

Design and Construction Standards SECTION PLUMBING EQUIPMENT

DOM-5. Domestic Hot Water Heaters & Boilers

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

Raypak Residential Products

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

mith Mills 3500A Smith Mills 3500A 3500A-3 OIL, GAS OR COMBINATION GAS/LIGHT OIL COMMERCIAL BOILER/BURNER CAST IRON

SAMPLE SPECIFICATIONS

Suggested Specifications Prestige Excellence 110

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

SECTION PLUMBING EQUIPMENT

DIVISION FINNED WATER-TUBE WATER HEATERS

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

High Capacity Instantaneous Steam Fired Water Heater

TABLE OF CONTENTS BRADFORD WHITE BOILERS

ENGINEERED DUPLEX ALLOY

Control and power circuit fusing to meet N.E.C.

FTIIIC-10. Domestic Hot Water Heaters and Boilers

DIVISION FINNED WATER-TUBE BOILERS

Thermal Fluid Heaters

BUDERUS. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. BUDERUS. G Cast Iron Commercial Boilers

WATER-TUBE POOL HEATERS

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

SECTION DOMESTIC WATER HEATERS

High efficiency, cast-iron gas boiler

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

FINNED WATER-TUBE POOL HEATERS

SPH Series. Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters CEMLINE CORPORATION

VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY.

Commercial Semi-Instantaneous Water Heaters

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

WATER-TUBE POOL HEATERS

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

Domestic Hot Water Heaters and Boilers FTIIIC-6

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

SERIES 19A. mith PRESSURIZED WET BASE

Series 8H. Cast Iron Gas Fired Commercial Water Boiler

PACKAGED COMMERCIAL WATERTUBE BOILERS

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications

Boilers Variable Fire Boilers

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Commercial Gas Water Heaters

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

96% COMMERCIAL INDUSTRIAL HEATER. Condensing Gas Water Heating System. Thermal Efficiency

Proven Heritage RTS STANDARD EQUIPMENT. (413) FAX: (413) You can rely on Smith Cast Iron

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

SECTION FUEL-FIRED DOMESTIC WATER HEATERS

CLM FORCED DRAFT WATER BOILER

Revitalize Building Mechanical Systems (4619)

Indirect Fired Water Heater

Peerless Boilers. Peerless Pinnacle. High Efficiency Stainless Steel Boilers

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS

Light Duty Commercial Electric Water Heater

Residential & Commercial

Boiler & Water Heater

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

FINNED WATER-TUBE POOL HEATERS

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Transcription:

Form No. 2300-7 (Rev. 2/99) Gas, il or Dual Fuel Fired Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity Originators of the Flexible Water Tube design

Bryan's exclusive features make Water-Pak so efficient Faster heat transfer Unique design of Bryan water tubes transmits the first blast of heat from flame to water much faster than this action occurs in ordinary heaters. Bryan heat exchanger constructed of heavy copper tubing, the efficient Bryan heat exchanger is bolted to the heater shell. Designed for two or six pass flow with low pressure drop, this exchanger easily handles the entire BTU output of the heater, or any Bryan Water-Pak "indirect storage water heating" is scale-free, corrosion-free and trouble-free Heat transfer fluid (Primary Water) recirculated by thermal action up through heater tubes, past indirect heat exchanger and down. This is the secret Service hot water circulated continuously through the copper indirect heat exchanger, absorbing hat from warm Primary Water. Service hot water does not come in contact with hot flue gases; this it remains below critical scaling and corrosion temperatures. Hot Service Water Non-ferrous water connections. Insulate tank jacket zinc coated enamel to match heater jacket (optional). Hot water storage tank 125 psi ASME Code Flue Gases to vent. Manhole 11" x 15" Diffuser Tube Cold Service Water. High temperature combustion gases heat Primary Water (heater transfer fluid) only. Burner gas, oil or gas-oil combination. Bronze circulation pump-- operates continuously to reduce stratification in storage tank during standby. Drain Internal tank lining for corrosion protection phenolic-epoxy, cement or copper. Structural steel skid. Burner Flame Heat Primary Water Hot Service Water Cold Service Water

Water-Pak Selection Water-Pak units are built to furnish a very wide selection of recovery rates, storage capacities and configurations. Both horizontal and vertical tanks are available to best fit into the space allocation. In addition to the combination of settings shown below, other combinations, arrangements and sizes are possible. Fuel selection includes gas (atmospheric or forced draft), oil. dual gas-oil and electric. 1. Select Heater Mode! based on Heater Specifications table below. 2. Select storage capacity from Storage Tank Specifications tables, horizontal or vertical tank depending on space considerations. 3. Choose appropriate Setting from Heater-Tank Setting diagrams below. Selection procedure example: A requirement of 800 gph at 100 rise. Storage capacity 1000 gallons. Fuel, gas. Tank lining, cement. 1. From Heater Specifications table, select heater Model No, CL-120WT Gas, rated at 820 gph, 40 to 140 rise. 2. From the Storage Tank Specifications tables, suppose you select the 1045 gallon horizontal tank. 3. Then the setting shown in diagram AH (horizontal tank) would be appropriate. Specify: Water-Pak System CL-120WT-G-1045-AH-CM-IN Recovery Heater Model Fuel G gas O oil GO gas-oil Storage Section Size (gals.) Setting Tank Lining CM cement PH phenolic CP copper Tank Insulated Jacket HORIZONTAL STORAGE TANK SPECIFICATIONS (Dimensions in inches. See note 2) Capacity Tank Tank Tank D F G J K in dia. length height Tapping Relief Hot Cold Tapping gallons including location valve outlet inlet location insulation tapping tapping tapping 199 30 78 50 25 3/4 11/2 11/2 46 387 36 102 56 25 3/4 2 2 68 520 42 102 62 29 3/4 2 2 62 802 42 150 62 30 3/4 21/2 21/2 108 1045 48 150 68 32 1 1/2 2 1/2 2 1/2 104 1546 54 174 75 30 1 1/2 2 1/2 2 1/2 132 2188 60 198 80 30 1 1/2 3 3 156 2699 72 174 92 34 1 1/2 3 3 124 3533 72 222 92 34 1 1/2 3 3 172 VERTICAL STORAGE TANK SPECIFICATIONS (Dimensions in inches. See note 2) Capacity Tank Tank Tank D F G J K in dia. length height Tapping Relief Hot Cold Tapping gallons including location valve outlet inlet location insulation tapping tapping tapping 199 30 78 50 25 3/4 11/2 11/2 46 387 36 102 56 25 3/4 2 2 68 520 42 102 62 29 3/4 2 2 62 802 42 150 62 30 3/4 21/2 21/2 108 1045 48 150 68 32 1 1/2 2 1/2 2 1/2 104 1546 54 174 75 30 1 1/2 2 1/2 2 1/2 132 2188 60 198 80 30 1 1/2 3 3 156 2699 72 174 92 34 1 1/2 3 3 124 3533 72 222 92 34 1 1/2 3 3 172 Note 2: All dimensions subject to change without notice. These dimensions are approximate only. Consult factory for certified drawings once design is esiablished. See applicable layout sheets for detailed dimensions HEATER SPECIFICATIONS Heater Capacity, Gallons per hour (see notes) Heater Heater 80 to 60 to 40 to 400 to 40 to Model Input 140 140 140 160 180 MBH Rise Rise Rise Rise Rise D/F350WT 350 550 415 330 N/A N/A D/F450WT 450 720 540 430 N/A N/A D/F650WT 650 1040 785 625 N/A N/A F850WT 850 1360 1025 820 N/a N/A CL75WT 750 1200 900 720 600 515 CL90WT 900 1440 1080 865 720 620 CL120WT 1200 1920 1440 1150 950 820 CL150WT 1500 2400 1800 1440 1200 1030 CL180WT 1800 2900 2160 1730 1440 1240 CL210WT 2100 3380 2540 220 1680 1440 K/RV250 2500 400 3000 2400 2000 1715 K/RV300 3000 4800 3600 2880 2400 2060 K/RV350 3500 5600 4200 3360 2800 2400 K/RV400 4000 6400 4800 3840 3200 2745 RV450 4500 7200 5400 4320 3600 3085 Note 1: Contact factory for ratings at other conditions. Note 2: Heater is not intended to provide the temperature increases shown about instantly, but will raise the temperature of the gallons listed to final storage temperature within one hour. Note 3: Select adequate storage tank capacity to handle peak demad. Keep in mind that, typically, only 75% of tank capacity is usable storage. Note 4: D Series and CL75 Series are forced draft only. Note 5: F Series are atmospheric gas-fired only.

CL Series Atmospheric (Jacket and tube access panels removed to illustrate water tube configuration) CL Series Forced draft (Jacket and tube access panels removed to illustrate water tube configuration) Approximate dimensions of package-length, width and height will vary, depending on the heater/ tank combination chosen for the application, SETTING AH: L =width of required heater plus length of tank required plus approximately 14' between heater and tank for service area. W= tank diameter plus 6" for jacket and insulation if this option is chosen. Or, the length of the heater required, whichever is greater. H= dimension shown in Horizontal Storage Tank Specifications table. in nearly all instances the tank height will be greater than the chosen heater. See Note 2 Approximate dimensions of package-length, width and height will vary, depending on the heater/ tank combination chosen for the application. SETTING AV: L= width of required heater plus diameter of tank required plus approximately 14" between heater and tank for service area. W= tank diameter plus 6" for jacket and insulation if this option is chosen. Or, the length of the heater required, whichever is greater. H= dimension shown in Vertical Storage Tank Specifications table. The tank height will be greater than the chosen heater. See Note 2 Approximate dimensions of package SETTING BH: L= length of required heater plus length of tank required plus approximately 14" between heater and tank for service area. W= tank diameter plus 6" for jacket and insulation if this option is chosen. Or, the width of the heater required, whichever is greater. H= dimension shown in Horizontal Tank Specifications table. In nearly all instances the tank height will be greater than the chosen heater. See Note 2

Bryan Water-Pak brings packages efficiency to large volume hot water needs. Hotels, motels, apartments, schools, industries, hospitals, institutions, restarants, laundries, packing plants get abundant, clean, low maintenance ho water at low cost. The Bryan Water-Pak is a completely packaged system comprised of the indirect Water Heater, Storage Tank and Circulation Piping, all mounted on a structural steel skid. All components are factory wired and assembled, requiring field hookup only of the cold and hot service water connections, the electrical supply, fuel source, and the vent connection. The Bryan Water- Pak utilizes the superior Indirect feature of the water heater, resulting in a highly efficient and scalefree operation. The service water does not come in contact with the high temperature heating surfaces, consequently, there is little possibility of scale and corrosion. Thousands of Bryan Indirect Water Heaters have been installed during the past 40 years, most all of them still rendering efficient service. The Bryan Water-Pak is engineered to provide a compact packaged unit for large volume water heating requirements. Available in many selections of Heater-Tank combinations, horizontal or vertical. Designed for long life, low maintenance and continued maximum efficiency performance. Each component of the Bryan Water-Pak is easily replaceable. The entire unit need not be replaced, as is often required by other types of water heater equipment. Storage tanks and water heaters comply with the recommendations of ASHRAE 90-75. COMPACT EFFICIENCY Floormiser designs that require an absolute minimum of valuable space. VERSATILITY Gas or oil fired: or dual-fired, gas-oil. TROUBLE-FREE SERVICE Since service water does not come in contact with high-temperature heating surfaces, corrosion and scale are virtually eliminated. Rely on Bryan for... LONG LIFE Bryan zinc coated casings, steel boiler tubing, copper heat exchangers, copper interconnecting piping and cement or phenolic epoxy lined storage tanks are constructed of the finest materials available to assure years of costsaving durability. CONVIENCE PACKAGING Automatic Bryan Water-Paks are shipped completely assembled, wired and tested lo reduce installation time and labor costs. EASY MAINTENANCE Bryan flexible water tubes are easily removable and replaceable, requiring minimum service space. APPROVAL Bryan Water-Pak systems are designed to ASME requirements. The years ahead will make you glad you selected Bryan

How to specify Bryan Water-Pak Indiect Storage Water Heater Systems THE WATER HEATER(s) shall be Bryan Indirect Water-Pak System, Model. Each heater shall have a capacity of GPH at a F to F rise with a firing rate of BTU and gallons storage capacity. It shall be factory assembled and wired with interconnecting piping and controls. The only field connection requirements shall be the cold water inlet, hot water outlet, fuel, electrical and vent. The indirect water heater shall be manufactured and stamped in strict accordance with ASME Code, Section IV. Heater water tubes shall be easily removable and replaceable without requiring welding or rolling. THE WATER HEATER shall be furnished complete with one or more indirect heat exchangers installed in the upper drum of the heater, heat exchangers being capable of absorbing 100% of the total heater output. Heat exchangers shall be attached to heater shell by means of a gasket and stud type connection and shall be easily removable and replaceable. THE WATER HEATER is to be complete with an insulated metal jacket, consisting of not less than 1 ^ fiberglass insulation and aheavy gauge zinc-coated steel easing, painted with a suitable hea-t-resist-ing primer and lacquer. Complete jacket and insulation shall be readily removable and re-installed il necessary. Combustion space shall be lined with insulating tile or board and no part of the jacket shall be exposed to the products of combustion. THE STORAGE TANK section shall be manufactured in strict accordance with ASME Unfired Pressure Vessel Code Section VIII, for a maximum working pressure of psi. Storage tank shall be lined with (Cement) (Phenolic Epoxy) (Copper). All threaded connections shall be stainless steel. Storage tank shall be mounted in a (horizontal) (vertical) position. A 12")(16" rnanhole shall be provided on tanks 42" diameter or larger. STORAGE TANK INSULATION - shall be factory installed 3" fiberglass insulation with zinc coated steel jacket. (Optional: furnished and field applied by the contractor.) AN ALL BRONZE CIRCULATING PUMP shall be installed to provide circulation between the storage tank and the water heater. All piping shall be copper and brass. The water heater, the storage tank and all pip-ing and accessories shall be mounted on a full-length structural steel channel base. THE WATER-PAK SYSTEM shall include the following fittings and trim: 1. Combination thermometer and pressure gauge on heater. 2. Temperature gauge on storage tank. 3. ASME-rated hot water pressure relief valve on heater. 4. ASME-rated hot water pressure relief valve on heat exchanger. 5. ASME-rated hot water pressure relief valve for tank. 6. Adequately sized expansion tank. 7. Low water cutoff on heater. 8. Automatic heater fill valve. 9. Heater water temperature control. 10. High limit temperature control. 11. Tank temperature control. 12. Shutoff valves between heater and tank. 13.Heater and tank drain valves. ATMOSPHERIC GAS BURNER AND CONTROL THE GAS BURNER UNIT shall be an integral part of the water heater. Burner shall be for operation with natural draft, requiring no motor or blower. The burner is to be equipped with an automatic electrically operated gas valve, a gas pressure regulator and manual shutoff valve. Gas pilot safety control shall shut down burner in case of pilot failure. A suitable barometric draft control or draft diverter shall be furnished. FORCED DRAFT BURNER AND CONTROL EQUIPMENT THE BURNER shall be Underwriters Laboratories listed suitable for operation with No. lor No. 2 fuel oil, natural gas, LPG, or other as required. Burner shall be complete with a blower for supplying sufficient combustion air with normal draft con-ditions. The burner shall be com-plete with automatic ignition. Refractory type combustion chamber to be installed in heater base, constructed ol high temperature insulating refractory. OPTIONAL ACCESSORIES AND CONTROL EQUIPMENT The following additional controls and accessories shall be furnished: 1. Hi-low-off,two-stage,gasburner controls. 2. Modulating burner controls. 3. Electronic pilot safety controls on atmospheric gas burner (standard with heaters 450 MBH and larger). 4. Electronic combustion safety controls on oil burner (standard with units exceeding l0 gph firing rate). 5. Induced draft fan of proper capacity. 6. Special insurance approval controls (FM, IRI, etc.). 7. Arrangements for space heating and service water heating multi-purpose system. The complete Water-Pak unit shall be factory assembled and furnished by the Bryan Steam Corporation. The manufacturers representative shall be responsible for furnishing startup and instruction service on the job. Bryan Steam Corporation Since 1916 P.O.Box 27, Peru, Indiana 46970-0027 U.S.A. Phone: 765-473-6651 Internet: www.bryanboilers.com Fax: 765-473-3074 E-mail: bryanboilers@iquest.net Form No. 2300-7 1999 Bryan Boilers Printed in USA 29-1898