CAPILLARY SAMPLING INTRODUCTION. Page 1 CAPILLARY SAMPLING

Similar documents
Aspirating Smoke Detection for Large Area Coverage Applications

Aspirated Smoke Detectors

VESDA ASPIRATING SMOKE DETECTION INDUSTRY GUIDE SUBSTATIONS

FireNET Vapor. Pipe Network Design Guide. June 2013 Document: 25845_00 Part Number: HA

Loss Prevention Standards

Perimeos. Ceiling Recess. decor. systems

ThermoCable Linear Heat Detection System

Intumescent Fire Dampers

Aspirating Smoke Detection

Fire safety management issues identified by fire risk assessments

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

SPRINKLER SYSTEMS UNDERCOVER-SPRINKLERS. Undercover-Sprinklers recessed and concealed sprinklers

Twin Wall Installation Instructions And Maintenance Guide

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

INSTALLATION AM ; AMC

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

REFRIGERANT PIPING SYSTEM

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

Mobile Food Units. A definition of mobile food unit added in OFC Rule 2 is as follows:

Data Centers. ASD 535 Application Report

FIREPRO SoftSeal System

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX

A P P L I C A T I O N S G U I D E. Single-Ended Reflected Beam Smoke Detector

GENERAL RULES. Ensure that the installation of your product conforms to all the indications given below. English CHIMNEY STACK

INSTALLATION AND MAINTENANCE INSTRUCTIONS TC866E Series LASER ASPIRATED SMOKE DETECTOR

INSTRUCTIONS. Duct Mount Kit Q900. Description. Operation

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

Course introduction 2. 1 Appliances and fuels 3. 2 Combustion Legislation Air supply Flues and chimneys Commissioning 83

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

Ceiling Mount Pre-Installation Guidelines

Installation and Maintenance Instructions

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

Fire resistance. Appendix E. E.1 Fire resistance. Appendix. (A copy of this Appendix is available on /)

Installation Instructions for use by heating contractor. VITOCELL r 300-H CAUTION IMPORTANT. Read and save these instructions for future reference.

METIS. Installation instructions. Riser rail kit INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER.

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers

Energysaver Space Heater Co-Axial Flue System Installation Manual

GE Security. air sampling pipe networks installation and design manual

Fire Risk Assessment. Guidance Notes. Location details. Risk Rating. Assessors. General notes

Power Generation. ASD 535 Application Report

CHAPTER 8 CHIMNEYS AND VENTS

ACS.CCLP1 PD SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC LPG PERMANENT DWELLINGS

i PSV WHOLE-HOUSE VENTILATION SYSTEM

FIRE RISK ASSESSMENT Self Assessment

LeakSafe. solutions. WaterSwitch2. Installation Instructions

RESOLUTION MSC.292(87) (adopted on 21 May 2010) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

FX-PDD Duct Smoke Detector Installation Sheet

CHIMNEYS AND VENTS CHAPTER 8

Wall Mount Electric Fire Place with Remote Control

Application and Installation Guide (excluding Solar Air Collectors)

DUCTING FOR HRV SYSTEMS The distribution of airflows

bout your HOUSE Hydronic Radiant Floor Heating CE 4

LASER ASPIRATED SMOKE DETECTOR

- CONSTRUCTION FIRE SAFETY STANDARDS

Optimum. Installation Instructions. A Shower Tray 1. Flange Plate. Screws. Bottle Trap. Extendable Flexi Waste Pipe. Drill Bit.

Making Crimp Connections

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

1 What is the name of the tool shown in the diagram? Basin wrench Footprint wrench Stilson wrench Torque wrench.

CENTRAL HOUSING GROUP LTD. General Property Standards Guide

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

Smoke extraction duct of sheet steel

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

SYSTEM MANUAL Description

B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page Installation Guide

EVX110 Extractor Installation, use and maintenance

Lo-Carbon Quadra SELV

NTD-125-*, NTD-204-* & NTD-220-* Nuaire Round & Rectangular Thermal Ducting Installation Guide

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

CEILING FED RISER RAIL KIT. Installation Guide. tritonshowers.co.uk/digital

Installation Instructions. (Applicable to all front door models)

INSTALLATION MANUAL Power Flued Flamefire Space Heater Co-axial Flue System

Pellet Stove. Flex Pipe. Appliance Connector

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold

BASE-RAY CAST IRON BASEBOARD RADIATION

Ceiling Systems 6 Intex Price Guide

IRRAD - PHASE II RADIANT COOLING - DESIGNING FOR FLEXIBLE PARTITION OF SPACE

H Y D R O C O U R S E T R E N C H H E A T I N G

INDOOR INSTALLATION AND VENTING

(SP4) SP420 (SP5) SP520 (SP9) SP920 AUS/NZ. 08/50019/5 Issue 5

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

EVX101 Extractor Installation, Use and Maintenance

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

Welcome to the. Firestop Seminar. Hilti Technical and Engineering Support

The Plastimo range provides a stylish, efficient and mechanically resistant answer MADA18

ELECTRICAL FIRE STOPPING SOLUTIONS

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

C. None (No sprinkler system) K3 E. NUMBER OF BEDS CERTIFIED FOR MEDICAID

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

TYPE 1 FIRE RISK ASSESSMENT REVIEW (NO DESTRUCTIVE AUDIT)

FireNET Vapor VPR-SD2

Aspirating Systems Design and Application Guide

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

Passive Fire Protection Guidance. Niall Rowan Technical Officer Association for Specialist Fire Protection

Transcription:

Page 1 Fig. 1 A typical concealed sampling installation. The capillary (or drop pipe sampling point assembly) places the sampling point in the same position normally occupied by a point type smoke detector. INTRODUCTION Capillary sampling is a method of locating smoke sampling points remote from the main sampling pipe. This is particularly useful where the main sampling pipe cannot be routed through the area requiring protection for either technical or aesthetic reasons. The actual capillary sampling point assembly may be known as a 'remote sampling point' or 'extended sampling point'. The technique uses short lengths (up to a maximum of 6 metres) of 10 mm outside diameter flexible tubing that branches off from the main sampling pipe as shown in figure 1. The far end of the flexible tube is fitted with an assembly including a restrictor that needs to be drilled to an appropriate size during commissioning to achieve the desired air flow rate for the application. A range of sampling point assemblies is available to suit different applications Typical applications for capillary sampling points are for the detection of smoke within poorly ventilated or sealed cabinets, below suspended ceilings, and for the protection of heritage/historic buildings where an unobtrusive installation is essential. When designing a system using capillary sampling points, consideration must be given to any standards or codes that may be applicable. In particular, care should be taken to place sampling points in the same postion that would otherwise be occupied by conventional smoke detectors. In the absence of any other guidance, it is recommended that a minimum of two capillary sampling points are sited in any room. This allows a degree of redundancy should any one hole become obstructed, although experience has shown this is unlikely. Fire standards and codes differ on issues such as the minimum distance smoke detectors or aspirating detection points can be positioned from walls and ceilings and it is stressed that the specific regulatory requirements should be observed wherever possible. Flexible capillary tube Pipe adaptor Sampling pipe Securing clip Ceiling panel In-line remote sampling point

Page 2 A variation of capillary sampling is the drop pipe method in which a branch of rigid pipe is taken from the main sampling pipe via a tee or Y coupling and terminated with an end cap that is drilled with a sampling hole of appropriate diameter. This technique is useful as it allows the principle of remote or concealed air sampling detection using standard sampling pipe materials. It also allows the air sampling holes to be extended away from the main pipe run to protect ceiling compartments or lantern lights and also to overcome stratification problems caused by heat barriers. Figure 2 shows the application of a drop pipe. Drop & stand pipes Sampling pipe Pipe adaptor Fig. 2 Application of drop pipe. Reducing connection Drop pipe (rigid) Ensure a good seal is made where the drop pipe passes through tile ceiling panel Ceiling panel Patress (if required) End cap with sampling hole

Page 3 Fig. 3 Using a stand pipe to extend sampling into a deep recess Sampling hole End cap Suspended ceiling Fig. 4 Using a stand pipe to extend sampling into a lantern light Sampling hole End cap

Page 4 There are applications where it may be aesthetically unacceptable or potentially hazardous to have a sampling pipe network running below a concrete slab ceiling. By drilling through from above it is possible to use capillary or drop pipe sampling. Care should be taken if the fire integrity of the compartments must be maintained and suitable intumescent seals fitted. Raised access floor Fig. 5 Sampling through a floor Main sampling pipe run Sleeve (intumescent if required) Intumescent sealant Concrete Sampling hole Sampling hole 1. An air sampling pipe network that includes the use of capillaries or drop pipes should follow the recommendations given in the guidelines for standard sampling pipe networks and system design. General guidelines 2. The minimum internal diameter for the capillary sampling tube should be 7.5mm for lengths up to 6 metres. 3. Drop pipes longer than 1 metre ideally should be reduced in diameter using proprietary fittings to a smaller diameter. This is to reduce the internal volume of the assembly, as a large volume tends to extend response times. The maximum recommended length is 4 metres. All drop pipes should terminate with an end cap drilled with a calibrated sampling hole. 4. Ideally the extended sampling points should be as short as possible and equal in length. This is often impractical and it is important to model the proposed system on PipeCAD to ensure that the system remains balanced. Longer extended sampling points will cause system response times to increase. 5. It is possible to mix extended and standard sampling points on one branch of sampling pipe but, it is important to model the system using PipeCAD to calculate the sampling hole diameters. A typical application is where the main sampling pipe run is concealed within a false ceiling void that requires smoke detection along with the room space below.

Page 5 6. Where the concealed sampling pipe runs through an area that is at a significantly different air pressure to the space being protected, it is important that all the extended sampling holes draw from the same pressure zone. It is also important that where a sampling point or drop pipe passes through into the protected space that a good seal is made around the penetration. This will prevent draughts reducing the efficiency of the sampling hole. Sampling from cabinets When protection is required inside equipment enclosures or cabinets, capillary or drop tube sampling can be adapted to give very efficient smoke detection. When protecting small sealed volumes, the sensitivity of the system will be high due to the relatively low smoke dilution. It is possible to cover a large number of enclosures using extended sampling points but consideration must be given to limiting the number of enclosures protected to a number that may be readily inspected by staff available if an alarm occurs. The extended sampling point should be arranged so that the air sampling hole is positioned in the likely path of any smoke generated from an incipient fire scenario. A system designed for in-cabinet protection should not be expected to provide protection for the environment outside the enclosures. If this is required it is recommended separate Stratos detectors are installed to meet the requirements of the relevant regulations, standards or codes of practice. Figure 5 shows a typical application that has the main sampling pipe run above the enclosures to be protected. From this pipe, capillary tubes are run down to the top of the enclosures where they pass into the enclosure using either a purpose-made sampling point or a bulkhead connector. Fig. 5 Sampling from equipment cabinets using capillary or remote sampling pipes Sampling main pipe run Bulkhead Capillary tube with drilled end plug Sampling point NB NB Note It is important that the capillary tube is properly secured where it passes into the enclosure. There must be no risk of the capillary tube being accidentally dislodged and a mechanical joint is strongly recommended. Note It is essential that the installation of sampling pipe does not impair operation of the equipment

Page 6 An alternative is to use a 'drop pipe' extended sampling point, either from above or below the cabinet. A typical application is shown in figure (4) Pipe adaptor Sampling pipe Fig. 6 Sampling from the top of an equipment cabinet using a drop pipe. Reducing connection Drop pipe Access plate Rubber grommet End cap with sampling hole Cabinet Where equipment cabinets without forced ventilation are installed on a raised access floor the main air sampling pipe can be run in the floor void and sampling points brought up through the base of the cabinets via capillary or drop (stand) pipes as shown in figures 5 & 6. The sampling holes should be strategically sited at the top of the enclosure.

Page 7 Fig. 5 Sampling from equipment cabinets via a floor void using a flexible capillary remote sampling point Nylon tube Calibrated sampling plug Cabinet Mounting clip Quick release reducing connector Raised access floor Main sampling pipe run

Page 8 End cap with sampling hole Fig. 6 Sampling from equipment cabinets via a floor void using a rigid stand pipe. Mounting clip Raised access floor Stand Pipe Cabinet Main sampling pipe run 'T' connector