Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Similar documents
Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

50TM COMBINATION HEATING/COOLING UNITS

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

50TM TFF COMBINATION HEATING/COOLING UNITS

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

48TM GAS HEATING/ELECTRIC COOLING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48PGD/E/F/L/M/N PG20-28

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

62DA,DB,DC,DD,DE,DF07-38

Product Data RELIABILITY FEATURES

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

DCG Commercial. Submittal Data Form

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

PAR5. Product Specifications

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

TAG: RTU-2B 3B 4B 5B 6B 7B 1E MODEL: QTY. (7) 48TCED14A3A5-0B0A0 PACKAGED GAS/ELECTRIC ROOF TOP UNITS

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Product Data. Features/Benefits. 50TJ Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz

90.1 COMPLIANT PACKAGED ROOFTOP HEAT PUMP UNITS, R 410A, TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

30GT FLOTRONIC AIR-COOLED CHILLERS

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

RGE 13 A T - 1 A

Model 542F Size 180 COMMERCIAL ROOFTOP PACKAGED HEAT PUMP. Bryant Air Conditioning. Form No. PDS 542F.180.2B. 15 Tons DESCRIPTION

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Model 581A COMMERCIAL GAS HEATING/ELECTRIC COOLING UNITS. Bryant Air Conditioning. Form No. PDS 581A.155.3B. 13 to 20 Tons DESCRIPTION

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. 48HJD,HJF HJ Single Package Rooftop Units. 12 to 20 Nominal Tons

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. Features/Benefits. 50LJQ Single-Package Rooftop Heat Pump Units. Nominal 3 to 10 Tons

WPH4 Product Specifications

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

PHD3. Product Specifications

30GN FLOTRONIC II AIR-COOLED CHILLERS

Input Cap. (Btuh) Stage 2

Highly Efficient,Powerful Heating and Cooling.

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Input Cap. (Btuh) Stage 2

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 48HJD,HJF HJ Single-Package Rooftop Units. 12 to 20 Nominal Tons

50KCQ Packaged Heat Pump 14 SEER 3to5NominalTons. Product Data C08613

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Product Data. Features/Benefits Every compact one-piece unit arrives fully assembled, charged, tested, and ready to run.

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Product Data. Fig. 1 - Unit 50EZ -A

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Model 655A Sizes

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50GX 3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

T CLASS ROOFTOP UNITS 60HZ Bulletin No July 2008 Supersedes August 2007

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)

Commercial Products Matrix. SUBJECT TO CHANGE WITHOUT NOTI CE TYPE OF SALE: 6JSS SHIPPING POINT: Lewisburg, TN

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Product Data. Features/Benefits. 48/50TJ Single-Package Rooftop Units 60 Hz. 15 to 25 Nominal Tons

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

Corp L2 Revised

GREEN REFRIGERANT R-410A

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

kw MRT150C Coming MRT180C MRT240C MRT300C

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

High Heat COP. High/Low Stage

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

WCH5**4. Product Specifications

Product Data. Features/Benefits. 50HJ Single-Package Rooftop High-Efficiency Electric Cooling Units. 3 to 12 1 / 2 Nominal Tons

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

RHX. Product Specifications

Model 702A SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS. 2 to 5 Nominal Tons UNIT 702A. Form No. PDS 702A.24.3

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

Transcription:

016---028 Single---Package Cooling Units with Factory---Installed Optional Electric Heat Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Copyright 2007 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date:3/07 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: ---5SB Replaces: -2SB

Job Data: Location: Buyer: Buyer P.O.# Carrier: Unit Number: Model Number: Unit Designation: Performance Data Certified By: S All units meet ASHRAE minimum efficiency Standard 90.1. S Standard one-year product warranty. S Five-year warranty on the compressor (016). One year warranty on the compressor (020-028). S Units are rated in accordance with ARI standard 360. Standard unit is certified and listed by ETL and ETL, Canada. S Low outdoor temperature cooling operation to 40_F (4_C) as standard. S Dual freezestat protection is provided as standard. S Dual scroll compressors with internal linebreak protection (TM028 has 3 compressors, circuit #1 has 2 compressors in tandem). S Indoor and outdoor coils constructed of aluminum fins mechanically bonded to seamless internally grooved copper tubes. S Dual TXVs (thermostatic expansion valves) metering devices. S Liquid line filter driers provided in each refrigeration circuit. S Optional gear-driven EconoMi$er IV equipped with microprocessor controller that includes CO 2 ventilation control capability. FEATURES DESCRIPTION units are one-piece rooftop cooling units with optional electric heat. All units are pre-wired and pre-charged with R-22 at the factory. Units are factory tested in both heating and cooling modes. The units have bottom air openings for separate supply and return ductwork. The unit is intended for installation on an accessory curb (ordered separately). Horizontal supply and return connections are also possible with a factory-preassembled, horizontal conversion adapter roof curb accessory (ordered separately). Bottom discharge on concentric applications requires a transition duct (field-supplied) external to the unit. S Manually adjustable outside air intake for up to 25% outside air. S Automatic changeover (when used with an auto-changeover thermostat). S Single point electric connections. Disconnect in accordance with NEC must be field-supplied and installed. S All units utilize 2-stage cooling. S Belt drive adjustable evaporator fan. S Choice of low-medium or high-static indoor fan drive capability. S Cabinet made of pre-painted, galvanized steel with baked enamel finish. S Cooling systems have low and high-pressure switches. Two in. disposable type return air filters are factory installed. S Provision for alternate end return in base unit. Horizontal supply available by using accessory curb. EconoMi$er IV may be used with horizontal supply and return. S Direct drive propeller condenser fans with vertical discharge. 2

Unit Operating Weight lb Cooling Gross Total Capacity: Btuh at Condenser Air Temperature F Gross Sensible Capacity: Btuh Compressor Power Input: kw Indoor Entering db F wb F Airflow External Static Pressure in.wg Indoor Fan Motor Size Hp Exhaust Fan Motor Size Hp PERFORMANCE DATA Curb Weight lb Heating Heating Capacity: Stage 1 Btuh Stage 2 Btuh Heating Capacity Total Btuh Stage 1 kw Stage 2 kw Heating Capacity Total kw ELECTRICAL DATA Power Supply to Unit Volts Phase Hz Minimum Circuit Amps Maximum Overcurrent Protection SUBMITTAL DATA Job Name Architect Engineer Contractor Unit Designation FACTORY-INSTALLED OPTIONS j Fully Integrated EconoMi$er IV, gear driven with Belimo Actuator (2-10vDC signal) and controller j Cu/Cu (tube/fin) condenser coils j Cu/Cu (tube/fin) condenser and evaporator coils j E -coat Al/Cu condenser j E -coat Cu/Cu condenser j Pre-Coated Al/Cu Condenser Coils j Hinged Access Panels j Service Option Package (hinged access panels, non -fused disconnect, non -powered 115v convenience outlet) j Manual 25% Outside Air Damper j Low -med static capability indoor fan drive j High static capability indoor fan drive j Low kw range electric heater j Mid kw range electric heater OPTIONAL WARRANTIES j (2nd to 5th Year) Extended Protection Plan on the Compressor (020, 025, 028) OPTIONS AND ACCESSORIES FIELD-INSTALLED ACCESSORIES j Fully Integrated EconoMi$er IV, gear driven with controller and Belimo Actuator (2-10v DC signal) j EconoMi$er 2, gear driven with Belimo Actuator (4-20mA signal) and without controller j Outdoor Air and Return Air Temperature Sensors (differential dry bulb control) j Return Air Enthalpy Sensor (single enthalpy control) j Outdoor and Return Air Enthalpy Sensors (differential enthalpy control) j CO 2 Sensor Duct Mount j CO 2 Sensor Wall Mount j Winter Start Package j Roof Curb (14 -in.) j Roof Curb (24 -in.) j Roof Curb (Horizontal Supply) j Factory Preassembled, Horizontal Conversion Adapter Roof Curb (TM016, 020 and 025 Only) j Power Exhaust j Barometric Relief j Thermostat and Subbase j Two -Position Damper Package j Motormasterr Control allows operations down to -20_F j Low Ambient Kit Down to 10_F (016, 020, 028) j Low Ambient Kit Down to 25_F (025) j Hail Guard (016, 020, 025) j Hydronic (Glycol) Coil j Electric Heat j Outdoor Air Thermostat j Time Guard II compressor anti-cycle protection 3

CERTIFIED DIMENSION PRINT 016, 020 C06347 4

CERTIFIED DIMENSION PRINT 025 C06349 5

CERTIFIED DIMENSION PRINT 028 C06350 6

CERTIFIED ROOF DIMENSION PRINT 016-025 C06340 7

CERTIFIED ROOF CURB DIMENSION PRINT 028 C06341 8

HORIZONTAL SUPPLY/RETURN ADAPTER DIMENSION DRAWING 016-025 ONLY Return Air Wood Nailer Supply Air Factory Supplied Transition Duct (Fully Insulated) Supply Air Supply Duct Opening Wood Nailer Rigid Insulation (Field Supplied) Roofing Material (Field Supplied) FACTORY PRE-A SSEMBLED HORIZONTAL SUPPLY/RETURN ADAPTOR ACCE SSORY CRRFCURB013A00 PKG NO. REF. CURB HEIGHT(ht) DESCRIPTION CRRCURB013A00 Factory Pre-Assembled Horizonal Adapter Curb with Transition Duct C06342 9

SERVICE OPTION DIMENSION PRINT 016-025 C06343 10

SERVICE OPTION DIMENSION PRINT 028 C06344 11