Fort Bragg Fire and Emergency Services Division Fire Safety Survey For use of this form, see FB Reg 420-1, the proponent agency for this form is DES.

Similar documents
Osceola County Department of Fire Rescue and Emergency Medical Services

Common Fire Code Violation Checklist. Listed are some of the most commonly found fire code violations and should not be considered as all inclusive.

Fire and Life Safety Review Form

Camden County Fire Rescue Office of the Fire Marshal 125 N. Gross Road, Kingsland, GA

Checklist For Building Inspection & Fire Safety

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

School Fire Safety Checklist

New Construction Fire Inspection Process

South Davis Metro Fire Agency

Business License Pre-inspection Checklist

Facility Manager Training

SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.

Clackamas Fire District #1 Self Inspection Program. Oregon Fire Code (OFC)

GENERAL AREAS OF INSPECTION

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Fire/General Safety Review Program Key Performance Indicators Environmental Health and Safety

APPLICATION CERTIFICATE OF OCCUPANCY $50.00 FEE (non-refundable)

Fire/Life Safety Policy

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

MOBILE FOOD VENDING Food Trucks & Trailers

Enki Health and Research Systems, Inc. WORKPLACE INSPECTION CHECKLIST AND CORRECTIVE ACTION FORM

Fraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.

Business Fire Inspection. City of Guadalupe

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

Goals of a Fire Prevention Program Fire Prevention Strategy Housekeeping Issues Flammable and Combustible Liquids Electrical Fire Hazards

GENERAL GROUNDS. Inspector Name: Inspector Signature:

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

FIRE SAFETY INSPECTION REPORT

HEALTH/LIFE SAFETY ANNUAL INSPECTION CHECKLIST (ROE)

Winnipeg Fire Department Fire Prevention Branch

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

FIRE SAFETY INSPECTION REPORT

To expedite the plan review and inspection processes, please refer to the information below.

FIRE SAFETY INSPECTION REPORT REDPOINT JACKETS LTD, DHAKA, BANGLADESH

West Chester Fire Dept. Fire Code Maintenance Handbook. Fire Prevention Saves Lives and Property

INITIAL FIRE SAFETY ASSESSMENT

FIRE SAFETY INSPECTION REPORT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

FIRE SAFETY PRACTICES AND PROCEDURES

Residential Care Facilities Having 6 or Fewer Clients Classified in the California Building Code as R-3.1 Occupancies

-SAMPLE- Safety Inspection Checklist: Manufacturing

General Festival Conditions & Temporary Use of Tents Conditions of Approval

Safety Manual Section 7 Fire/Life Safety

Minimum Information Required to Process your Special Occasion Application. Parking area Access to site

OUTLINE FOR FIRE PREVENTION ACTIVITY

REGULATIONS FOR OUTDOOR GATHERINGS AND EVENTS TENTS & MEMBRANE STRUCTURES

FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES

Fire Sprinkler Plan Submittal Form

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

Wausau Fire Department Inspection Violation Code Listing (Modified) All Applicable Records

OAK GROVE SCHOOL DISTRICT SCHOOL SITE FIRE PREVENTION PLAN

OCCUPANCY INSPECTION FORM

MULTI-LEVEL & COVERED BOOTH CONDITIONS

System Test Report CLEAN AGENT

Dear Exhibitor, To assist in th. and safety issues that you may encounter with your booth.

Agency for Health Care Administration

Apartment Fire & Safety Inspection. City of Guadalupe

Life Safety - Means of Egress/Exits NFPA 101

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

FIRE SAFETY INSPECTION REPORT

COMPLIANCE WITH THIS PUBLICATION IS MANDATORY

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

Department of Planning & Community Jefferson Station 1526 E. Forrest Avenue Suite 100 East Point, GA 30344

C i t y o f G r o v e r B e a c h ADMINISTRATIVE SERVICES DEPARTMENT

General Industry Safety and Health Checklist Guidelines. Building and Premises. Loss Control Bulletin

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

Building Self-Inspection Program

Denver Fire Department Fire Prevention Division

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

New Facilities. Minimum Requirements

ADMINISTRATIVE SERVICES MANUAL

Informational Bulletin

BOABC Level III Exams 7, 8, 9 and 10 Beginning April 1, 2015

Outdoor Festival and Special Event Guidelines

Ten-Point Checklist for Emergency Preparedness

Letter of Recognition

OCFEC Fire Marshal Summary Report

FIRE SAFETY INSPECTION REPORT

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

Rental Housing Initial Inspection Checklist Community Development Department 208 NW 1 st Ave., Faribault, MN

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

CHRISTIAN BROTHERS RISK MANAGEMENT SERVICES Self Inspection Checklist

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

Warehouse Operations Safety Inspection Checklist

CITY OF OKLAHOMA CITY SPECIAL EVENT REQUIREMENTS Revised January, 2011

Sandra P rior Director, EH&S

FIRE SAFETY INSPECTION REPORT

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

Accreditation Program: Hospital

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

INITIAL FIRE SAFETY ASSESSMENT

Facility Risk Assessment Questionnaire

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Transcription:

Fort Bragg Fire and Emergency Services Division Fire Safety Survey For use of this form, see FB Reg 420-1, the proponent agency for this form is DES. Date of Survey: Building Number: UNIT / Organization: Unit Fire Safety Marshal Representative: (UFSM) Phone Number: Organization Commander: Commander Phone Number: Note: List all information related to any failures noted during the survey in the remarks section below. What is being done to correct the failed situation? Examples: (Item 1 a) Service order (#xxxxxxx) submitted to have the door latch fixed. (Item 3 f) We have called xxxxxxxx Fire Extinguisher Company to have our Fire Extinguishers re-inspected and / or re-serviced. (Item 11 b) Failure was corrected on the spot. (Trash, boxes etc. against building were disposed of properly). 1) EXITS: a. EXITS OPERATIONAL PASS FAILS * Exit Excess * Exit (i.e. Doors, Hardware, Latches, and etc.) * Exit Discharge b. FREE FROM OBSTRUCTIONS PASS FAILS c. EXIT SIGNS PASS FAILS (Note: Are exit signs clear, unobstructed and posted in all required areas to ensure the path of egress is recognizable. If illuminated, must be working.) 2) FIRE ALARM SYSTEMS: a. AUDIBLE DEVICES PASS FAILS N/A (Note: Is the device intact no damage?) b. SMOKE / HEAT DETECTORS PASS FAILS N/A (Note: Is the device intact no damage? If battery operated or backed up, are batteries good?) c. MANUAL PULL STATION PASS FAILS N/A (Note: Is the device intact; no damage?) 3) FIRE EXTINGUISHERS: a. EASE OF ACCESS PASS FAILS (Note: i.e.visual; Can Fire Extinguisher be seen from all locations? Access; any obstructions?) b. PROPER INSTALLATION PASS FAILS (Note: Locations, mounting and height.) c. HYDROSTATIC TEST DATE PASS FAILS d. FULLY CHARGED / SERVICEABLE PASS FAILS (Note: i.e. Pin, Safety Seal, Guage, Hose, Horn and no obvious damage.) e. INSTRUCTIONAL LABLES LEGIBLE PASS FAILS f. ANNUAL SERVICE DATE PASS FAILS (Note: Inspected and tagged by certified personnel) 1

4) SPRINKLER SYSTEMS: a. RISER UNOBSTRUCTED PASS FAILS N/A (Note: Must maintain Fire Department access at all times) b. OUTSIDE FIRE DEPT. CONNECTIONS CLEAR & UNOBSTRUCTED PASS FAILS N/A (Note: i.e. Fire Department Connections, Sprinkler Standpipe) (Note: Must maintian Fire Department access at all times and be free of obvious damage.) c. SPRINKLER HEAD CLEARANCE PASS FAILS N/A (Note: A minimum of 18 inches) d. SPRINKLER HEADS CLEAN PASS FAILS N/A (Note: i.e. free from dirt, debris, paint, greases, etc / no objects attached to or hanging from heads) 5) BUILDING: a. DOORS PASS FAILS (Note: All hardware serviceable: Closures, Latches, etc.) b. WINDOWS PASS FAILS N/A (Note: Will they open and/or can they be used for a means of egress?) c. STAIRS / STAIRWELL PASS FAILS N/A (Note: Not used for storage of equipment; i.e. Vending machines, bikes, lockers etc.) (Note: No items on or under stairs) d. FIRE ESCAPE PASS FAILS N/A (Note: Is the equipment serviceable?) 6) ELECTRICAL: (Note: All equipment must be UL or CUL approved and tested.) a. MULTIPLE OUTLETS PASS FAILS b. SURGE PROTECTORS PASS FAILS (Note: Must have a 15 amp breaker and be plugged directly into an outlet.) c. IMPROPER WIRING PASS FAILS (Note: Is fixed electrical wiring properly installed? NOimproper wiring!) d. EXTENSION CORDS PASS FAILS * Only appropriate gauged extension cords may be used. (IAW Manufactures Recommendation) *They may only be used on temporary basis. *When used, they must be routed correctly (not through walls, over doors etc.) *Can not be used as permanent wiring. e. FRAYED WIRING PASS FAILS (Note: Are all appliance/equipment wires in safe working condition?) f. HAZARDOUS LOCATIONS PASS FAILS (Note: Are all areas secured from water, exposed wiring, weather etc.?) g. SWITCHES and FIXTURES PASS FAILS (Note: Are all switches & fixtures installed properly, securely, safely and undamaged?) h. FUSES and PANEL BOXES PASS FAILS (Note: Are fuse & circuit breaker control panel boxes secured, undamaged, and properly marked?) 7) SELF CLOSING FIRE DOORS: a. FUSIBLE LINK PASS FAILS N/A (Note: Is link/release in place and system operational?) b. RATED PASS FAILS N/A (Note: Is door listed to meet requirements of occupancy?) c. HARDWARE PASS FAILS N/A (Note: Is all hardware in good enough condition to remain operational?) d. OPERATIONAL PASS FAILS N/A (Note: Are doors in proper working order and good condition. Doors CAN NOT be held open by unapproved means. I.e. door stops, ties,etc.) 2

8) STORAGE: (Note: All hazard materials storages and handling must be maintained IAW; XVIII Airborne Corps and Fort Bragg Regulation 385-10) a. COMPATABLILITY PASS FAILS N/A (Note: Are flammable materials separated as needed?) b. STORAGE METHOD PASS FAILS N/A (Note: Are flammale compressed gases secured from falling and damage?) c. CONTAINERS PASS FAILS N/A (Note: Are flammable materials stored in proper containers and protected?) d. ITEMS LABELED PASS FAILS N/A (Note: Are flammable materials labeled correctly?) e. WARNING SIGNS / PLACARD PASS FAILS N/A (Note: Are required warning signs posted identifying presence of flammable liquids and/or gases?) 9) FUEL STORAGE: (Note: DPW controls Mechanical Rooms; make a note if access is denied) a. FUEL PIPE PASS FAILS N/A b. FUEL LINES PASS FAILS N/A c. SPACING BETWEEN VEHICLES PASS FAILS N/A (Note: Ref; Ft Bragg's web site for command policies regulating designated areas for LP Tanks, Diesel Tanks, Trucks, Fuel storage, etc.) 10) COOKING a. COOKING EQUIPMENT PASS FAILS N/A (Note: Is equipment safe to use, and in proper working order?) i.e. Are authorized cooking appliances UL approved? Are they on a non-combustible surface?) b. DEEP FAT FRYERS PASS FAILS N/A (Note: Thermostat annually tested, protected by suppression system, etc) c. OVENS / BURNERS PASS FAILS N/A (Note: Are ovens/burners safe clean, and in proper working order?) d. EXHAUST HOOD(S) PASS FAILS N/A (Note: Are exhaust hoods cleaned as required to include filters?) e. Commercial Fire Extinguishing / Suppression Systems PASS FAILS N/A Note: * Are nozzels free of dirt, grease, etc? * Are nozzels' covers in place? * Are signs and labels in compliance? * Do the systems have a valid inspection by a certified company? 11) HOUSEKEEPING: a. VEGITATION GROWTH PASS FAILS (Note: Is growth controlled in and around building, along fence lines, and throughout the area?) b. OUTDOOR HOUSEKEEPING PASS FAILS (Note: Is exterior maintained properly, i.e. clean, orderly, and safe?) c. RUBBISH PASS FAILS (Note: Is combustible waste and refuse stored in proper containers and disposed of as needed?) * (Reference; Ft Braggs' dumpster policy.) d. IMPROPER STORAGE PASS FAILS (Note: Are items stored by an approved storage methods?) * (Reference; DPWs' Environmental Compliance Policy for Hazardous Material Storage.) e. GENERAL ORDER PASS FAILS (Note: Is the worksite maintained in a safe, clean, and orderly manner?) 3

12) LIFE SAFETY: a. OCCUPANCY LOAD PASS FAILS N/A (Note: Is occupant load posted where required?) b. EXIT REQUIREMENTS PASS FAILS (Note: Are exit requirements of area being met? Are they operational and unlocked?) (i.e. Lighting, handrails, stair treads) c. EXIT IMPEDIMENTS PASS FAILS (Note: Are means of egress clear, obvious, and unobstructed?) d. EMERGENCY LIGHTING PASS FAILS N/A (Note: Are required emergency lights operational, in service, and tested monthly?) e. EXIT LIGHTS PASS FAILS N/A (Note: Are lighted exit signs operational?) f. EXIT SIGNS PASS FAILS (Note: Are required exit signs posted, clear and unobstructed?) g. RAMPS PASS FAILS N/A (Note: Are ramps clear, unobstructed, and in good condition? Do they meet handrail width and incline requirements?) h. INTERIOR FINISH PASS FAILS (Note: Do all interior finish materials meet the code requirements?) i. SMOKE BARRIERS PASS FAILS N/A (Note: Are required smoke barriers in place with no unsecured penetrations?) 13) FUEL HANDELING: a. PIPE LEAKS PASS FAILS N/A (Note: Are pipes / joints clean and leak free?) b. DEFUELING PASS FAILS N/A (Note: Is defueling procedure safe and in compliance?) c. REFUELING PASS FAILS N/A (Note: Is refueling procedure safe and in compliance?) d. GROUNDING PASS FAILS N/A (Note: Are proper grounding procedures being performed? Are grounding points tested at least twice each year?) e. BONDING PASS FAILS N/A (Note: Are proper bonding procedures being followed?) f. NOZZELS PASS FAILS N/A (Note: Are nozzels intact, approved, and leak free?) g. DISTANCE TO BUILDING PASS FAILS N/A (Note: Is product stored outside, more than (50) fifty feet from the nearest occupied building?) h. WARNING SIGNS / PLACARDS PASS FAILS N/A (Note: Are storage areas marked with proper signage on all approachable sides?) i. PUMP(S) PASS FAILS N/A (Note: Are pumps grounded and bonded?) 4

REMARKS: (Please include the number and letter that correlates to each discrepancy) 5