OEM Alpha Thermostat direct Analog

Similar documents
COMFORT IP: Room Control Unit Radio with Display

Control solutions Biofloor

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Heat Link. Technical Guide

Installer Manual KNX Touchscreen Thermostat

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Room thermostats with LCD for wall mounting

Instruction FH-CWP Thermostat

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

Wall-mounted room thermostat with LCD

TR 0603mc U Solar Controller

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

ACCESSOIRES ELECTRICAL ACCESSORIES

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

Self-learning Room Temperature Controller

FLAME AMPLIFIER MODULE 3001

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION

Catalogue 2015 AHU N Range: VENTUS VS 10 - VS 650

ARATON 2100 TX 1 AURATON 2100 TX. Advanced Remote Control Programmable Thermostat

Use. For 2-pipe fan coils

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

INTELLICOMFORT CH180WIFI TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION FOR REMOTE CONTROL

product overview ProControl

Operating Instructions SUPERSTAR E-6000 / F2 for 1 1/2, 2 and VAC

Semi flush-mount room thermostat

Room controller. RC is a room controller from the Regio Mini series intended to control heating and cooling in a single zone.

N M AirControl AHU. Control manual

Flush-mounted room thermostat

Pre-programmed room controller with communication

REA22 Room Temperature Controller

Room controllers with manual forced ventilation function

Application guide RDG160 Remote control

INSTRUCTIONS REHAU SILENT DIAL THERMOSTAT #

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Room thermostat with Auto Timer, Option External Input

T105 Advanced Remote Control Programmable Thermostat. User Manual

The Right Temperature, Always THS Series Modular Thermostats

Pre-programmed room controller with communication and hidden setpoint

Mixer module VR 61. Operating and Installation Manual. Mixer module for VRC 430 / VRC 430f

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Room thermostat with Auto Timer, Option External Input

Preliminary Release. Room Temperature

T5000 LCD Digital Fan Coil Thermostat

Room thermostat with Auto Timer, Option External Input

Interface and EOL Modules 8

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat.

Wireless room thermostat with LCD

Panel Mounted Fault Annunciator Series

FLAME AMPLIFIER MODULE 3001D

Smart Thermostat RDS110

Speed and Frequency Seite 1 von 7

Panel Mounted Fault Annunciator Series

Retroreflective sensor with polarization filter

GB Art. Nr

Rittal roof-mounted fans Efficiency on top

Combi B Alarm box. Mounting instructions

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Self-learning Room Temperature Controller

Type ETO2. Controller for ice and snow melting 67222A 04/14 (JRK) GREEN COMFORT Maximum comfort with low energy consumption OJ Electronics A/S

Saving energy while ensuring an enhanced room climate

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

PRELIMINARY EDITION

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS

Life insurance for your electronics

Self-learning Room Temperature Controller

Self-learning Room Temperature Controller

Perfect match for Carrier fan coil units Carrier Thermostats & Valves

UDC100 Universal Digital Controller Specifications

Flush-mounted room thermostats

Dissolved Oxygen Measurement liquisys S COM 223 / 253

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

Semi flush-mount room thermostats

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

Heating Controls Technical

Underfloor Catalogue Heating products that define the market

Sensors and Detectors

Room thermostats with LCD RDD100..

ASD 535 Aspirating smoke detector

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

LCF Touch Modbus Datasheet Application Security Advice Caution

Dew point set DS 400

FIL-SPL Flow-through heater for central heating USER MANUAL

APPLICATION DATA SHEET

LCF Touch (from firmware version 1.7)

FR-A180 FR-A360. Occupancy detector. Use

Controller for evaporator control AK-CC 750

BC3250. Blowdown Controller

Advance Optima Module Magnos 17

ACCREDITED. Product range Code A2L Modulating temperature regulating unit for heating and cooling, with ALPHA2 L pump.

Room Temperature Controller

T7984 A,B,C Electronic Modulating Control Thermostats

EMO T. Thermal actuator for heating, ventilation, and air conditioning systems. To be precise.

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Transcription:

OEM Alpha Thermostat direct Analog The OEM Alpha Thermostat direct Analog is a high-quality room thermostat in modern design for the registration and regulation of the desired room temperature, offering maximum user comfort. The OEM Alpha Thermostat direct Analog is available for the operating voltages 24 V and 230 V. A simple room-by-room temperature control is already possible with directly connected actuators. In conjunction with the connection unit OEM Alpha Basis direct, a perfectly matched overall system for surface temperature adjustment can be realized. The desired room temperature can be set comfortably via a rotary control with soft ratchet. A set value calibration as well as a limitation of the setting range are also possible. Two versions can be chosen in order to comply with the desired installation requirements. Depending on the selection, applications for heating or heating/cooling is possible. All versions of the OEM Alpha Thermostat direct Analog are marked by their high-quality appearance, integrating harmoniously into a modern room architecture not least due to its slim design. An optimum price-performance ratio is offered for rooms where only a very good temperature control is desired, without the comfort function of the display variant. 1.1 Features Available in two versions: Analogue and Analogue HK Versions in 24 V and 230 V Flat design and small dimensions (86 x 86 x 29 mm) Regulation in stand-alone or in the system Equipment for heating and cooling systems Reduction input for room temperature reduction Target value calibration Limitation of the target temperature setting range Valve and antifreeze protection function Change-over input High-quality, modern OEM design High functional security The Möhlenhoff OEM product quality ensures easy, intuitive installation, operation and maintenance of the entire system. 1.2 Variants In the basic version, the OEM Alpha Thermostat direct Analog will be delivered as neutral device without logo and in white. The subsequent list shows the available versions. Type Model Operating voltage Equipment Scope of supply R 40203-10N4 Analogue 24 V R 40203-40N4 Analogue HK 24 V R 20203-10N4 Analogue 230 V R 20203-40N4 Analogue HK 230 V Heating, fixed reduction temperature, reduction input, target value calibration, antifreeze function Heating/cooling, fixed reduction temperature, reduction input, change-over input, cooling blocking, target value calibration, valve protection function, antifreeze function Heating, fixed reduction temperature, reduction input, target value calibration, antifreeze function Heating/cooling, fixed reduction temperature, reduction input, change-over input, cooling blocking, target value calibration, valve protection function, antifreeze function OEM Alpha Thermostat direct Analog in individual packing Instructions in 12 languages +49 5341 8475 0

1.3 Equipment The OEM Alpha Thermostat direct Analog is offered in the versions 24 V and 230 V. Different versions are available; they differ in their functional equipment. Analogue Analogue HK Heating Cooling Cooling block Change-over input Reduction input Fixed setback difference Set value calibration Valve protection function Antifreeze function 1.4 Accessories Type Target value limitation Article description Insertable set point limiters for temperature range limitation 1.5 Optional differentiations to the basic version Differentiation possibilities Packaging Individual printing and manufacturing of packaging Casing Individual designs, e. g. square, upright, horizontal format, individual colour Imprint on casing Marking of the company logo and the individual type designation and the device designation Installation bottom Colour adaptation, form change Please contact us if you have further wishes. +49 5341 8475 0

2 Function All room thermostats OEM Alpha Thermostat direct Analog have the same basic functions; further system functions depend on the version and the individual equipment. 2.1 Device overview (example Alpha Thermostat direct Analogue HK) Top view Clamp contacts Set value element rear view 1 Set value element Setting the target temperature - Fixed reduction temperature of 4 K 2 Comfortable clamp terminals Screw terminals - Quick connection of a multi-core connection line for voltage supply and signal transmission 3 Protective cover Protection against accidental contact of life components 4 Target value limitation Specification of the minimum and maximum adjustable room temperature by mechanical limitation 5 Set value calibration Adjustment of the internal temperature sensor by ±2 K 2.2 Protection functions A valve and an antifreeze protection function are integrated into the thermostat for damage protection purposes: Valve protection function - Cyclic activation of connected actuators, avoids the clogging of valves in times without temperature control - Will be activated once every 14 days for 6 minutes after the last triggering Antifreeze protection - Avoids the freezing of lines during times without temperature control (e. g. in case of longer absence) - Inactive in cooling operation 2.3 Operation 2.3.1 Setting the comfort temperature The thermostat can be operated comfortably via the set value element. The user sets the desired temperature by simple turning. +49 5341 8475 0

2.3.2 Set value calibration The target value calibration integrated into the set value element allows a set value balance of -2 K to 2 K in 0.25 K increments. 1 2 3 4 2.3.3 Limiting the temperature range Two set point limiters can be inserted into the removable set value element, allowing a limitation of the temperature range. One of the limiters sets the minimum, the other one the maximum settable room temperature. 1 2 3 4 +49 5341 8475 0

3 Technical data The listed technical data relate to the maximum functional equipment of the OEM Alpha Thermostat direct Analog. Individual positions may be omitted depending on the model. 24 V variant 230 V variant Analogue Analogue HK Analogue Analogue HK Type R 40203-10N4 R 40203-40N4 R 20203-10N4 R 20203-40N4 Operating mode Heating Heating/Cooling Heating Heating/Cooling Operating voltage 24 V ±20 % 50 Hz 230 V ±10 % 50 Hz Voltage supply via base/transformer via base/mains connection Power consumption in idle operation <0.3 W Switching element Triac Triac Relay Relay Switching power 1 A ohmic load 1.8 A ohmic load, 200 VA inductive Fuse T1A T2AH max. number of connectible actuators 5 (max. 3 W/actuator) 10 (max. 3 W/actuator) Rated current w/o valve drives 20 ma 20 ma 2 ma 2 ma Max current draw allowed with connected valve drives 1 A 1 A 1.8 A 1.8 A Control direction of actuators to be connected NC Target temperature setting range: 10 C to 28 C Target temperature resolution 0.25 C Actual temperature registration (int. sensor) 0 40 C Measuring accuracy of internal NTC ± 0.5 K Set value calibration ±2 K Change-over input - switchable via potentialfree contact - switchable via potentialfree contact Cooling block - Yes - Yes Reduction input Yes Reduction temperature 4 K Antifreeze temperature 6 C Valve protection function - once every 14 days for 6 minutes - Admissible ambient temperature 0 to 50 C Admissible storage temperature -25 to +75 C Admissible ambient humidity 80%, not condensing Temperature for ball pressure test 550 C Type of installation On-surface wall installation once every 14 days for 6 minutes Connection line NYM-J 5 x 1.5 mm² NYM-O 5 x 1.5 mm² NYM-J 5 x 1.5 mm² NYM-O 5 x 1.5 mm² Connection Analogue 5 screw terminals - 0.22 mm² to 1.5 mm² terminals Analogue HK 7 screw terminals - 0.22 mm² to 1.5 mm² Protection class III II Rated impulse voltage 1500 V Pollution degree 2 Type action Typ 1 Typ 1 Typ 1.C Typ 1.C Degree of protection IP 20 Material PC + ABS Surface structure anodised Colour set value element Signal white (RAL 9003) Casing Signal white (RAL 9003) Weight 90 g Dimensions (W x H x D) 86 x 86 x 29 mm +49 5341 8475 0

3.1 Dimensions 86 81 All indications in mm 86 3.2 Approvals and certificates 23 29 81 In addition to our numerous internal function and quality tests, all Möhlenhoff products are tested by independent testing institutes. The product is certified by the TÜV Rheinland. +49 5341 8475 0

4 System visualisations A selection of possible system variants for the realization of a room-by-room temperature control is shown in the following. A stand-alone system can already be performed with one OEM Alpha Thermostat direct Analog and with directly connected actuators. The connection of up to ten actuators is possible depending on the voltage version of the thermostat. An individualisation of the room-by-room temperature control can be realized by adding to the system of compatible components, as e. g. the OEM Alpha Basis direct, the OEM Alpha Thermostat direct Display, and the thermal actuator of the type A 20x05 (230 V) or A 40x05 (24 V) with a power input of 1 watt 4.1 Stand-alone Heating/Cooling 230 V version 4.2 Thermostat with OEM Alpha Basis direct Standard PLUS 230 V version 4.3 Thermostat with OEM Alpha Basis direct Comfort 24 V version Characteristic Heating Cooling 1 Simple pump control Extended pump/boiler control with lead time and follow-up time Connection for external system clock ² Internal timer of an OEM Alpha Thermostat direct Display Temperature limiter or dew point sensor OEM Alpha Thermostat direct Analogue OEM Alpha Thermostat direct Analogue HK OEM Alpha Thermostat direct Standard OEM Alpha Thermostat direct Control 1 Only version Analogue HK ²not in combination with the external timer of an OEM Alpha Thermostat direct Control Characteristic Heating Cooling Simple pump control Extended pump/boiler control with lead time and follow-up time Connection for external system clock ² Internal timer of an OEM Alpha Thermostat direct Display 1 Temperature limiter or dew point sensor OEM Alpha Thermostat direct Analogue OEM Alpha Thermostat direct Analogue HK OEM Alpha Thermostat direct Standard OEM Alpha Thermostat direct Control 1 not in combination with an external system clock ² not in combination with the external timer of an OEM Alpha Thermostat direct Control Characteristic Heating Cooling Simple pump control Extended pump/boiler control with lead time and follow-up time Connection for external system clock ² Internal timer of an OEM Alpha Thermostat direct Display 1 Temperature limiter or dew point sensor OEM Alpha Thermostat direct Analogue OEM Alpha Thermostat direct Analogue HK OEM Alpha Thermostat direct Standard OEM Alpha Thermostat direct Control 1 not in combination with an external system clock ² not in combination with the external timer of an OEM Alpha Thermostat direct Control or timer module +49 5341 8475 0

5 Installation notes The installation of the OEM Alpha Thermostat direct Analog can be performed in a few simple, comfortable and intuitive steps. 5.1 Installation place A freely accessible area is recommended for installation in order to allow the OEM Alpha Thermostat direct Analog to detect the correct room temperature. There must be no additional heat sources at the installation position which could affect the thermostat. 5.2 Installation The OEM Alpha Thermostat direct Analog is installed comfortably on-surface or in a flush-type box in a few simple steps. 1 2 3 4a 4b 5 6 7 +49 5341 8475 0

5.3 Electric connection The wiring between the OEM Alpha Thermostat direct Analog and the components to be connected is realised with a multi-core cable. Analogue Analogue HK Mains connection - Voltage supply via OEM Alpha Basis direct or via an external voltage source Reduction input - Reception of an external reduction signal for the time-controlled reduction of the room temperature, from an OEM Thermostat Alpha direct Control, or an OEM Alpha Basis direct Control, or an external system clock. Change-over input - Toggle between heating and cooling via an external signal (potential-free contact) Connection for actuators 5.4 Blocking of cooling For the room thermostats Analogue HK, the cooling function can be blocked by inserting a cable bridge. 1 2 +49 5341 8475 0