Dry desiccant dehumidification systems. Product guide

Similar documents
Liquid desiccant dehumidification systems. Product guide

Dry Desiccant Engineering Reference Guide

AFD Industrial Dehumidifier Series

TYPICAL CPA SPECIFICATIONS

THE ULTIMATE ROOFTOP SOLUTION

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Principles of Active Desiccant Operation. Presented by Tom Peterson, CEO and Founder. Climate by Design International

RT-OA TM Rooftop Outdoor-Air (DOAS)

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

AFD DEHUMIDIFIER SERIES

Energy Recovery with Cooling and Heating Model ERCH

By MIKE WEST, PHD, PE Advantek Consulting Inc. Melbourne, Fla.

Chilled Water DOAS Fan Powered Terminal Units

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

CHAPTER 4. HVAC DELIVERY SYSTEMS

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

XeteX, Inc. All Rights Reserved.

Air Make-Up Units. Product Line Overview & Capabilities

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

The ultimate fresh air solution.

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Cultivator & Hybrid Cultivator

Benefits Offered by Passive Dehumidification Wheel Speed Control

Energy Recovery with Cooling and Heating

DES CHAMPS PRODUCTS 85% 4,400 CFM

Alfa Laval Touch Control

Our energy efficient experts and engineers have made ground breaking innovations in this field.

PRODUCTS. Configurable Packaged Air Handling Equipment VRC SERIES

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

Heat Recovery Units. Heat Recovery 1

DRYAIR Turnkey Dry Room Standards

Outstanding Performance; Application Flexibility

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Flexible & Innovative. Cooling Solutions

White Paper. Executive Summary. Overview of Membrane Exchangers CLCH-PRB063A-EN. June 2017

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

CHILLED WATER DATA ROOM UNITS

Pharmaceutical Facility Design

Submittal Data Performance Data Electrical Data

Power and Energy Management Solutions

ALL PRODUCTS BROCHURE

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

Modular Baghouse Dust Collectors

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

Modular Supply Make-Up Air Unit

Dehumidification for Industrial Coating Applications. By: Jay Kranker Munters MCS

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

MODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Adsorption Chillers Energysmart Green Cooling

Summary Comparison of Simulation Program Features

Heat pump and energy recovery systems

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

RoofPak Applied Rooftop Systems

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

Direct Fired Heater Model AD Specification

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Direct Gas-Fired Make-Up Air Models DG and DGX

1.1 This section applies to air handling units for HVAC Systems.

Make-Up Air Systems. Performance. Model DGK, DG, DGX

C13-Series Engineering Guide

IPAC. Invicta Precision Air Control Floor Standing Range

FITOCLIMA 600 & 1200 STABILITY

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Tulsa, OK Longview, TX

FITOCLIMA 600 & 1200 STABILITY

Guide Specifications PART 1 GENERAL 1.01 SUMMARY

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

VariCool VAV Engineering Guide

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

Scholar III Unit Ventilator

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

HEALTHCARE SURGERY VENTILATION HUMIDITY CONTROL

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

Dehumidification: Energy Efficiency Comparisons

Enthalpy Wheel and its Application in Air Conditioning

Direct Gas-Fired Make-Up Air Models DGK, DG and DGX

DESICCANT AIR DRYERS. BD + CD + CD series

CLEAN, DRY COMPRESSED AIR

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

DESICCANT AIR DRYERS. BD + CD + CD series

Humidity Control & Psychrometrics

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Mastering the elements

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

Liquid Desiccant Engineering Reference Guide

Blow through unit coolers LEX. Standard coolers for cooling & freezing rooms

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

Transcription:

Dry desiccant dehumidification systems Product guide

dvanced dehumidification Leading dry desiccant technology enefits of dry technology: Dehumidification independent of cooling est suited for warm, dry applications (less than 20% relative humidity) Low discharge humidity range apable of achieving as low as -65 F (-54 ) dew point Economic value comparison With increased awareness of energy costs, companies evaluate the total cost to own and operate equipment, rather than initial cost alone. n lfa Laval Kathabar evaluation considers the first cost, installation cost and operating costs for dry and liquid desiccant dehumidification systems. We then calculate the cost for various systems and present the economic value comparison based on specific SHRE local weather data, customers actual energy costs and system operating schedule. To ensure the evaluation does not leave anything up to question, we then compare both liquid and dry desiccant systems to conventional refrigeration systems, in order to determine the best solution for your specific needs. Simply ask your lfa Laval Kathabar representative to prepare an economic value comparison for your application. Sea level imperial units lfa Laval Kathabar dehumidification systems are engineered solutions for temperature and humidity control for industrial, commercial, educational, institutional and green/leed facilities. These cost-effective dehumidification and energy recovery systems have been used to clean and dehumidify air for a wide range of industries worldwide including pharmaceutical, investment casting, healthcare, cold storage, food and beverage, and many more. These systems help to improve the reliability, economy and efficiency of any manufacturing or processing operation that is humidity, temperature or microorganism-sensitive. Whether your space conditions are 78 F and 20% RH, 45 F and 40% RH, or -20 F and -40 F dew point, the lfa Laval Kathabar system can provide controlled conditions resulting in an improved bottom line. omplete packaged systems ll components found in a typical air handling unit can be packaged into the dry desiccant dehumidifier Humidity control (+/- 2% RH) djustable leaving air humidity level based on wheel face and bypass along with reactivation modulation Modulating capacity control Lower energy requirements than traditional refrigeration sub-cool and reheat systems Use readily available utilities Reactivation with direct or indirect fired natural gas, electric or high pressure steam Thermally insulated Two inch foam insulation (R-13) in a double wall construction Large capacity range Standard airflow capacities up to 11,000 FM; custom air capacities up to 25,000 PM are also available. Temperature ( F) Humidity ratio (gr/lb)

How it works Performance curves lfa Laval Kathabar dry desiccant systems operate on the principle of adsorption. This occurs as the process air comes in contact with the desiccant media, the moisture from the air is attracted to the desiccant surface much like metal filings are to a magnet. The desiccant wheel is constructed in a parallel honeycomb matrix, which is composed of a fiberglass substrate, impregnated with silica-gel providing the necessary surface area for the adsorption process. The desiccant wheel is housed in a cabinet that is separated into two sections, denoted as the process and reactivation sections. While in operation, the wheel is continuously rotating in and out of the process, and reactivation sections are at a rate of 6-15 rotations per hour. See the below illustration for a representation of this layout. In the process section, moist air passes through the wheel where the silica gel adsorbs the moisture. During this process of adsorption, heat is generated resulting in the leaving air becoming not only drier, but warmer. In the reactivation section of the wheel, a scavenger airstream is heated up and sent through the wheel. The moisture on the desiccant is attracted to the scavenger airstream which is exhausted, completing the reactivation process. Desiccant core The performance curves provide the approximate discharge grains expected at specific inlet conditions. Each curve represents a different velocity profile across the desiccant wheel with the 300 and 500 feet per minute values correlating to the minimum and maximum airflows for each unit. For example a 65 F, 60 Gr/# process air inlet with a velocity of 300 FPM results in a discharge grain condition of approximately 10 Gr/#. (The red arrows in the first performance curve correlate to this example.) 300 FPM (Min. airflow on the standard unit) 284 F reactivation temperature 99 Gr/# react moisture inlet 6 RPH wheel rotation Process outlet (Gr/#) Leaving air Process inlet (Gr/#) ir entering wheel 400 FPM 284 F reactivation temperature 99 Gr/# react moisture inlet 11 RPH wheel rotation Process outlet (Gr/#) Process inlet (Gr/#) 500 FPM (Max. airflow on the standard unit) 284 F reactivation temperature 99 Gr/# react moisture inlet 14 RPH wheel rotation Process outlet (Gr/#) Process inlet (Gr/#)

lfa Laval Kathabar DD Dry desiccant system components lfa Laval Kathabar DD Dry desiccant reactivation components E D G I H J M Steam reactivation. Steam coil: opper tube, aluminum finned with 16 G galvanized steel casing and carbon steel headers. Single point utility connections. Optional coil configurations are available F K L N O Q. Heavy duty 12 G galvanized framing with mineral wool insulation. Insulated cover for ease of access to the coil Gas reactivation. VFD driven direct drive reactivation fan with TEF premium effcient motor. Filter module with filter differential pressure indication gauge. Standard reactivation RTD s with programmable transmitters D. Mineral wool insulated reactivation ducts E. Instrument test port for ease of performance verification F. Standard, actuated face and bypass dampers for precise and fast acting humidity control G. Heavy duty wheel rotation confirmation limit switch H. High purity silica gel desiccant media in a 304SS housing and heavy duty square tube framing Gas unit shown J. Heavy duty 12 and 16 G epoxy painted galvanized paneling with 2 inch, R13 insulation K. able trays for ease of cable routing and servicing L. Heavy duty industrial epoxy painted -channel base with stitch welds M. Modular reactivation sections offer ease of service N. High temperature, aluminum framed reactivation filter(s) O. Reactivation filter door with integrated differential pressure gauge P. VFD driven direct drive process fan with TEF premium effcient motor Q. NEM 3R control panel with PL and HMI with external ethernet and power receptacle P Electric reactivation D E. Low NoX aluminum direct fire NG/LPG burner. Heavy duty 12 G galvanized framing with mineral wool insulation. NFP 86 compliant gas train with dual acting solenoid valve; Hi/Lo limit switches and integral pressure regulator D. Gas modulating control valve to allow for up to 20:1 turn down ratio of the burner E. Visual flame indication sight glass. SR modulated open face chromel coil with tubed and finned tubed as optional. One inch insulated, 304SS NEM 4 terminal box. Heavy duty 12 G galvanized framing with mineral wool insulation I. VFD driven fraction HP wheel motor with easily serviceable chain drive

lfa Laval Kathabar DD Dry desiccant sizing and selection lfa Laval Kathabar DD Dry desiccant optional components lfa Laval Kathabar dry desiccant system sizing is primarily dependent on airflow. The table below outlines the standard equipment sizing, along with weights and recommended airflow ranges. onsult with your representative for additional sizing options. lfa Laval Kathabar dry desiccant systems can be customized to meet almost any application. elow is a list of typical pre- and postprocess options. onsult your representative for additional options and configurations that may be required for your application. ase unit options. Indoor / outdoor configuration Process / reactivation weather hoods ccess door windows Special exterior paint Preprocess modules Postprocess modules Other options Unit size irflow (maximum) irflow (minimum) pproximate dimensions pproximate weight FM M3/hr FM M3/hr Inches entimeters Lbs Kg L W H L W H 60 1,700 2,889 600 1,020 130 54 58 330 137 147 2,100 1,000 150 2,200 3,738 1,200 2,039 130 56 64 330 142 162 2,300 1,100 300 3,100 5,267 1,700 2,889 132 70 72 335 177 182 2,700 1,300 450 5,200 8,835 2,400 4,078 136 82 83 345 208 208 3,700 1,600 600 7,600 12,913 3,800 6,457 141 90 96 355 223 243 4,600 2,100 900 11,000 18,690 5,700 9,685 145 98 105 368 243 267 5,600 2,700 ustom sizing and options up to 25,000 FM available upon request... Mixing box: ottom, end, top, side inlet and outlet Dampers manual or actuated Panel filter: Merv 7/8 two inch pleated pre-filter E. Process coils pre/post: Process heating - Steam - Hot water Process cooling - hilled water - ooling tower water - Direct expansion Filter magnehelic Process humidification D. Primary filter: F. Process fans: Merv 7/8 two inch pleated pre-filter Merv 8-14, HEP cartridge or bag filters Single/dual filter magnehelic Direct drive/belt drive Radial/I/F type Plenum fan Flow sensors

lfa Laval Kathabar DD Dry desiccant control options and system operations Dehumidification system dry application questionnaire ustomer data Project name: Name: lfa Laval Kathabar dry desiccant systems utilize a touch screen interface or (HMI), combined with a programmable logic control (PL) with Modus Ethernet connection. elow are some advantages of using this type of configuration along with added options that can be provided to better suit the needs of your application. Panel features Visual overview of the equipment with a user-friendly touchscreen interface. ctive visual trending which can be exported to an Excel file. Ethernet connection for remote monitoring and/or editing of the control points. NEM 3R enclosure for weather or wash down protection. ompany: ddress: ity, State, Zip: ountry: Phone: E-Mail: Outside air requirements Desired space conditions Panel options llen-radley, Siemens PL and HMI configurations. irflow: FM OS temp: F and Space temp: F Space humidity: Gr/lb. net and other MS interfaces are available upon request. OS humidity: Gr/lb. Variations in control sequences and components are available. System operation lfa Laval Kathabar dry desiccant systems use a standard dewpoint sensor to control the discharge and return air humidity precisely. elow is a general description of our standard control sequence for each reactivation type. ustom control sequences can be developed on an application basis. Electric reactivation The dew point controls the face and bypass dampers directly for immediate reaction to humidity range. The reactivation inlet wheel temperature is then adjusted by modulating the electric SRs. Space loads Sensible load: tu/hr Latent load: ru/hr Winter humidification required?: Yes No Utilities oolant source: oolant temp: F Heating source: or Delivered conditions to space irflow: FM Delivered temp: F Delivered humidity: Gr/lb. Electrical characteristics Voltage: (Volts) Phase: Frequency (Hz): Steam reactivation The dew point input controls the face and bypass dampers directly for immediate reaction to humidity range. The face and bypass dampers modulate the reactivation airflow across the coil. Gas reactivation The dew point controls the face and bypass dampers directly for immediate reaction to humidity range. The face and bypass modulate the gas control valve, to reduce the reactivation temperature set point. Hot water temp/steam pressure: F / PSIG Please describe the location for the equipment installation. Provide room sketches with doors, slots, etc. lfa Laval Kathabar, Phone +1 716-875-2000, Email: sales.kathabar@alfalaval.com, Web: www.kathabar.com

lfa Laval in brief lfa Laval is a leading global provider of specialized products and engineered solutions. Our equipment, systems and services are dedicated to helping customers to optimize the performance of their processes. Time and time again. We help our customers to heat, cool, separate and transport products such as oil, water, chemicals, beverages, foodstuffs, starch and pharmaceuticals. Our worldwide organization works closely with customers in almost 100 countries to help them stay ahead. How to contact lfa Laval lfa Laval Kathabar Phone +1 716-875-2000 Email: sales.kathabar@alfalaval.com Web: www.kathabar.com ontact details for all countries are continually updated on our website. Please visit www.alfalaval.com. PFL00082 1510