DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

Similar documents
DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Product ID. General. TE CONNECTIVITY SENSORS /// EXxxHyy Ex-Atex & NA 09/2017 Page 1

M7100 Pressure Transducer

M5200 Industrial Pressure Transducer

D5100 Industrial Differential Pressure Transducer

U5300 Industrial Pressure Transducer

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

D5100 Industrial Differential Pressure Transducer

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

M5800 Pressure Transducer with Rotatable Display

LOW PRESSURE Intrinsically Safe Transducer AST44LP

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

M5800 Pressure Transducer with Rotatable Display

U5700 Submersible Liquid Level Pressure Transducer

PT9420 (Extended Range)

DP86 Constant Voltage with Fitting

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

MSP100 Pressure Transducer

MODEL 834M1 ACCELEROMETER

SUBMERSIBLE Flush Diaphragm Liquid Level Sensor AST4520

PT9600. Cable Actuated Encoder Reel. General. Environmental

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

Cable Actuated Sensor Industrial Incremental Encoder Output

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

OPERATION MANUAL MODEL & ACCELEROMETER

PT9150 (Extended Range)

MODEL 4000A & 4001A ACCELEROMETER

PT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Standard SPECIFICATIONS FEATURES APPLICATIONS

MSP100 Pressure Transducer

15203B 25203B 35203B Uniaxial Biaxia Triaxial

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

MSP340 Pressure Transducer

Sub psi SPECIFICATIONS

Quadrature Speed and Direction Sensors

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

OPERATION MANUAL Model 8011 & mA

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

OPERATION MANUAL MODEL 805 ACCELEROMETER

P125 High Pressure Sensor

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

Cable Actuated Sensor Industrial User Scalable VDC Output

Cable Actuated Sensor Industrial User Scalable 4 20mA

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

U5600. Wireless Pressure Transducer SPECIFICATIONS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

OPERATION MANUAL MODEL 3255A ACCELEROMETER

FC22 Compression Load Cell

DTS SERIES CONNECTORS

LCZ Series Hall-effect Zero Speed Sensors

MODEL ACCELEROMETER

MSP300 Pressure Transducer

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Specification Status: Released

TS105-10L5.5MM Thermopile Sensor

TSYS02S Digital Temperature Sensor

OPERATION MANUAL MODEL 8102 ACCELEROMETER

HM1520LF Relative Humidity Module

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

HM1500LF Relative Humidity Module

MS4525 SPECIFICATIONS

MEAS EMITTER ASSEMBLY ELM-4000 SERIES

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

ELAF LOAD CELL SPECIFICATIONS FEATURES

Specification Status: Released

89BSD Digital Output

86BSD Digital Output

86BSD Digital Output

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

OPERATION MANUAL MODEL 4610 ACCELEROMETER

TE Connectivity's AMP NETCONNECT Cable Management

OPERATION MANUAL MODEL 3038 ACCELEROMETER

UV-SCE. Ultra-Violet light, Resistant TECHNICAL DATASHEET. Heat Shrink Identification Marker Sleeves

DOG2 MEMS SERIES USB INCLINOMETER

REA 105 Arc Protection Module. Operator s Manual

TSEV01S01C10 SPECIFICATIONS

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Operations Manual. Motion Detector Module Model ZS10

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR ANDROID

86A SPECIFICATIONS. 316L SS Pressure Sensor Small Profile V High Level Output Gage, Absolute ASIC Calibrated

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

More Precision. indusensor // Linear inductive displacement sensors

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

FC23 Compression Load Cell

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

Raychem Overvoltage Devices. ROV05, ROV05H 5mm Series Metal Oxide Varistors

ENERGY /// RAYCHEM CABLE CLAMPS RAYCHEM CABLE CLAMPS. Quick Reference Guide

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

OPERATION MANUAL MODEL mA

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Transcription:

Product ID Type # Product # Drawing # 378Z-05380 DSS 1210.00 STV (5m) 113807 374Z-04996 DSS 1210.02 PHV 112705 374Z-05052 DSS 1210.02 SHV (2m) 112865 378Z-05864 DSS 1210.12 AHV 115675 378Z-05910 DSS 1210.13 PHV 115903 3782606920 DSS 1210.14 AHV 117504 3742609304 DSS 1210.16 SHV 121449 3742612758 DSS 1210.17 AHV 126095 3742612759 DSS 1210.18 AHV 126095 378Z-05107 DSS 1410.06 PHV 112987 378Z-05178 DSS 1610.05 SHV (5m) 113111 374Z-05161 DSS 1610.06 AHV 113171 374Z-05224 DSS 1610.07 AHV 113171 374Z-05180 DSS 1610.08 AHV 113171 374Z-05625 DSS 1610.09 AHV 114614 3742607432 DSS 1610.10 AHV 114614 374Z-05310 DSS 1810.09 PTV 113532 374Z-05082 DSS 2210.01 SHV (5m) 110777F2 374Z-05083 DSS 2210.01 SHV (L=..m) 110777F2 3742607119 DSS AB10.00 AHV 118284 374Z-05661 DSS AB10.00 PHV 114709 374Z-05037 DSS EH10.01 PHV 112803 374Z-05051 DSS EH10.01 S1HV (2m) 112773 General Function The speed sensors DSS are suitable, in conjunction with a pole wheel, for generating square wave signals proportional to rotary speeds. They have a static behavior, so that pulse generation is guaranteed down to a speed corresponding to a frequency of 0 Hz. The sensing element is a magnetically biased Hall device followed by a short-circuit proof push-pull output stage. The sensor function is independent of the rotational orientation of the sensor axis. TE CONNECTIVITY SENSORS /// DSS SERIES 09/2017 Page 1

Certification These sensors are approved by Germanischer Lloyd (GL) Certificate n 45 500 07 HH Technical data Supply voltage Current consumption Signal output Frequency range 8 V to 30 V, protected against reverse polarity Max. 15 ma (without load) Square wave signals from push-pull stage, DC-coupled to the supply (negative pole = reference voltage) Push-pull outputs: Imax = +/- 20 ma, Ulow < 2.5 V, Uhigh > Usupply-3.5 V The outputs are short circuit proof and protected against reverse polarity. 0 Hz... 15 khz Electromagnetic According to 2004/108/EC, IEC 61000-6-2, IEC 61000-6-4: compatibility (EMC): Electrostatic discharge into housing, cable shield and wires: up to ±4 kv peak according to IEC 61000-4-2,severity level 2 Radiated electromagnetic field according to IEC 61000-4-3 Up to 30 V/m, 80% AM, 1 khz in the range of 80 MHz... 1000 MHz Up to 20 V/m, 80% AM,1 khz in the range of 900 MHz... 2700 MHz Radiated electromagnetic field: up to 30 V/m, 80% AM, 1 khz in the range of 1 MHz to 1000 MHz according to IEC 61000-4-3, severity level 3 Fast electrical transients/bursts, coupled to sensor cable with a capacitive coupling clamp: up to ±4 kv peak according to IEC 61000-4-4, severity level 4 Housing Stainless steel 1.4305, front side sealed hermetically and resistant against splashing water, oil, conducting carbon- or ferrous dust and salt mist. Electronic components potted in chemical and age proof synthetic resin. Max. allowable pressure on sensor head: 10 bar Dimensions according to drawing. Pole wheel Toothed wheel of a magnetically permeable material (e.g. Steel 1.0036) minimum tooth width 6mm Side offset < 0.2 mm Eccentricity < 0.2 mm Air gap between sensor/ Pole hole Insulation Protection class Vibration immunity Shock immunity Temperature Air gap between pole wheel (involute gear) and sensor housing: Module 1: 0.2...0.6 mm Module 2: 0.2...1.5 mm Housing and electronics galvanically separated (500 V/50 Hz/ 1 min) IP68 (head) and connector according to list 5 g in the range of 5... 2000 Hz Shock 50 g for 20 ms, half sine wave Operating temperature of sensor head: - -40 C... +125 C For sensors with cables the temperature range may be limited, see tables below. TE CONNECTIVITY SENSORS /// DSS SERIES 09/2017 Page 2

Connector type Sensor Type Connection Type Jaquet Part Number of Connector DSS 1210.00 STV (5m) Cable 824L-37338 DSS 1210.02 PHV Cable with integrated connector 824L-33024 (cable) 820P-36527 (connector) DSS 1210.02 SHV (2m) Cable 824L-33024 DSS 1210.12 AHV Connector 820A-36702 DSS 1210.13 PHV Cable with integrated connector 824L-33024 (cable) 820P-36546 (connector) DSS 1210.14 AHV Connector 820A-36702 DSS 1210.16 SHV Cable 824L-35053 DSS 1210.17 AHV Connector 820A-36584 DSS 1210.18 AHV Connector 820A-36584 DSS 1410.06 PHV Cable with integrated connector 824L-36222 (cable) 820P-36964 (connector) DSS 1610.05 AHV Connector 820E-31142 DSS 1610.05 SHV (5m) Cable 824L-35053 (cable) DSS 1610.06 AHV Connector 820E-31142 DSS 1610.07 AHV Connector 820E-31142 DSS 1610.08 AHV Connector 820E-31142 DSS 1610.09 AHV Connector 820E-31142 DSS 1610.10 AHV Connector 820E-31142 DSS 1810.09 PTV Cable with integrated connector 824L-35053 (cable) 820A-36859 (connector) DSS 2210.01 SHV (5m) Cable 824L-35053 DSS 2210.01 SHV (L=..m) Cable 824L-35053 DSS AB10.00 AHV Connector DSS AB10.00 PHV Cable with integrated connector 824L-36622 (cable) 820E-37696 (connector) DSS EH10.01 PHV Cable with integrated connector 824L-33024 (cable) 820P-36527 (connector) DSS EH10.01 S1HV (2m) Cable 824L-35053 DSS EH10.01 SHV (5m) Cable 824L-35053 DSS EH10.02 SHV Cable 824L-33024 TE CONNECTIVITY SENSORS /// DSS SERIES 09/2017 Page 3

Cables Jaquet Cable Type 824L-33024 824L-35053 824L-36222 824L-36622 824L-37166 824L-37338 Properties PTFE Teflon cable, 3-wire, 0.6 mm² (AWG 20), outer-ø max. 4.7 mm, bending radius min. 70 mm, strand shielded screen (metal net), white Operating temperature: -90 C to +260 C FEP Teflon cable, 4-wire (brown wire is not connected), 0.2 mm² (AWG 24), outer-ø max. 4.2 mm, bending radius min. 60 mm, strand shielded screen (metal net), white Operating temperature: -100 C to +150 C FEP Teflon cable, 4-wire (white wire is not connected), 0.6 mm² (AWG 20), outer-ø max. 4.7 mm, bending radius min. 24 mm, strand shielded screen (metal net), white Operating temperature: -60 C to +150 C Silicone cable, 6-wire, 0.6mm² (AWG 20), outer-ø max. 13.0 mm, bending radius min. 65 mm, strand shielded screen (metal net), black Operating temperature: -40 C to +150 C PUR cable, 3-wire, 0.6 mm² (AWG 20), outer-ø max. 6.2 mm, bending radius min. 75 mm, strand shielded screen (metal net), black Operating temperature: -40 C to +85 C PUR cable, 4-wire, 0.34 mm² (AWG 22), outer-ø max. 5.1 mm, bending radius min. 50 mm, green Operating temperature: -40 C to +85 C Connectors Jaquet Connectors Type 820A-36702 820A-36859 820E-31141 820E-31142 820E-37696 820P-36527 820P-36546 820P-36964 820A-36584 Degree of protection Manufacture Code Escha EWAS3P, 3 pole connectors, M12x1, material PA66-GF25, male plug, gold plated pins Escha WASS4 Operating temperature: -30 C to +90 C MS3106A-10SL-3P MS3102A-10SL-3P/H 097 ITT Cannon KPT06A12-3P AMP 282105-1 Operating temperature: -40 C to +125 C AMP 282087-1 (Super seal 1.5 Series) Female connector, 3 pins, black Operating temperature: -40 C to +125 C Deutsch DT 04-3P Operating temperature: -40 C to +125 C Escha EWAS4, 4 pole connectors, M12x1, material PA66-G25, male plug, gold plated pins Sensor head: IP69 If applicable: Cable outlet: IP67 Connector (plug-and-socket connection): IP67 TE CONNECTIVITY SENSORS /// DSS SERIES 09/2017 Page 4

Further Information Safety Connection Installation Maintenance Transport Storage Disposal All mechanical installations must be carried out by an expert. General safety requirements have to be met. The sensors must be connected according to sensor drawing. Sensor wires are susceptible to radiated noise. Therefore, the following points have to be considered when connecting a sensor: The sensor wires must be laid as far as possible from large electrical machines. They must not run parallel in the vicinity of power cables. The maximum permissible cable length is dependent upon the sensor voltage, the cable routing, along with cable capacitance and inductance. However, it is advantageous to keep the distance between sensor and instrument as short as possible. The sensor cable may be lengthened via a terminal box located in an IP20 connection area in accordance with EN 60529. The sensor has to be aligned to the pole wheel according to the sensor drawing independent of its rotational orientation. Deviations in positioning may affect the performance and decrease the noise immunity of the sensor. During installation, the smallest possible pole wheel to sensor gap should be set. The gap should however, be set to prevent the face of the sensor ever touching the pole wheel. The amplitude of the output signal is not influenced by the air gap. A sensor should be mounted with the middle of the face side over the middle of the pole wheel. Dependent upon the wheel width, a certain degree of axial movement is permissible. However, the middle of the sensor must be at minimum in a distance of 3 mm from the edge of the pole wheel under all operating conditions. A solid and vibration free mounting of the sensor is important. Eventual sensor vibration relative to the pole wheel can induce additional output pulses. The sensors are insensitive to oil, grease etc. and can be installed in arduous conditions. Within the air gap specified the amplitude of the output signals is not influenced by the air gap Product cannot be repaired Product must be handled with care to prevent damage of the front face. Product must be stored in dry conditions. The storage temperature corresponds to the operation temperature. Product must be disposed of properly; it must not be disposed as domestic waste. CONTACT US Tel +41 61 306 8822 jaquet.info@te.com te.com/sensor solutions JAQUET, TE Connectivity, and TE connectivity (logo) are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity s obligations shall only be as set forth in TE Connectivity s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. 2017 TE Connectivity Ltd. family of companies All Rights Reserved. TE CONNECTIVITY SENSORS /// DSS SERIES 09/2017 Page 5