EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Similar documents
EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CS90H INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

BD80 / BD80-XE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CS90E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

ECO85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

K100P DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL PD120 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD35 / CD35P INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL PD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL PD120 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E DEHUMIDIFIER (FULL PRODUCT RANGE) OWNER S MANUAL

FREE STAR INDUSTRIAL DEHUMIDIFIER USERS MANUAL

Superdryer Dehumidifiers

GL-DEH Series Portable Dehumidifier Operating Instructions

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Portable Dehumidifier

Portable Dehumidifier with Internal Pump

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

EBAC MODEL GENESIS AVENGER APOLLO AIR MOVER OWNER S MANUAL

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

Quest Dry 105, 155, and 205 Dual

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

Portable Dehumidifier with Internal Pump Portable Dehumidifier with Internal Pump OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Installation & Operation Manual Ice Cream Freezers

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

InstructIon Manual KrEs EQuIPMEnt stands

WatchDog NXT60. Installation and Operations Manual. Seaira Global, LLC NC Highway 50 Surf City, NC (910)

Room Air Conditioner Service and Parts Manual

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Quest 105, Dry155, and 205 Dual

Model 1870F Dehumidifier Installation and Operating Manual

ROTARY CONTROL AIR CONDITIONER

SLIDER CASEMENT AIR CONDITIONER

OPERATING INSTRUCTIONS

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

XD-125 OWNER S MANUAL COMMERCIAL DEHUMIDIFIER

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

Model 1850F Dehumidifier Installation and Operating Manual

AIR CONDITIONER ELECTRONIC CONTROL

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

IW-25-2 Dehumidifier Installation & Operations. Manual

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

5) Do not start or stop the unit by inserting or pulling out the power plug.

Operating Instructions

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

Owner s Manual Phoenix Arctic Max

SERVICE MANUAL. CG2 Commercial Grade Dehumidifier. SLS Part Number

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

Power Pack Service Manual

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

Power Pack Service Manual

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

POWER PACK SERVICE MANUAL

CUBE ICEMAKER MODELS SCU25, SCU35, SCU45, SCU75, SCU95, SCU120 INSTALLATION AND SERVICE MANUAL VERSION 2

GALE FORCE VAF-16R. Ventilation Manual

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

Split Floor-Mounted Cooling System Operation Care Installation Manual

Owner s Manual Phoenix 200HT

T-Series Air Conditioner T15 Model

e Bath Fan with Light User s Guide

DEHUMIDIFIERS FDK54 USE AND MAINTENACE MANUAL

Instruction Manual Item No.: V~, 60Hz

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

OPERATION MANUAL. CLASSIC 10 and CLASSIC 18 SERIAL NUMBER FROM JANUARY 2009 (0109) TO PRESENT

READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION OR OPERATION.

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

INSTRUCTIONS! DO NOT DISCARD!

Quest DRY quest. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest DRY 180:

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

Power Pack Service Manual

Transcription:

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL KOMPACT OWNERS MANUAL Page 1 of 9

INTRODUCTION Designed for a wide range of applications, the Kompact is a rugged, industrial unit, which utilizes an energy-efficient compressor and a compact portable design to provide easy efficient drying. The Kompact has a number of special features: High efficiency rotary compressor Ebac s Hot Gas defrost system Hours run meter Integral pump out system Provision for permanent drainage All galvanized interior Exterior epoxy powder-coated finish Rugged trolley for portability Extra long power cord The fan draws the moist air through the cold evaporator coil, which cools the air below its dew point. Moisture forms on the evaporator coil and is collected in the condensate tray, which is equipped with a permanent drain. The cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling phase, plus the additional heat generated by the compressor. The air is, therefore, discharged from the dehumidifier at a slightly higher temperature with a lower absolute humidity than that which entered. Continuous circulation of air through the dehumidifier gradually reduces the relative humidity within the area. The Kompact dehumidifier is a rugged, reliable drying unit designed to operate effectively over a broad range of temperature and humidity conditions. An active hot gas defrost system, controlled by an electronic timer, guarantees positive de-icing, thereby optimizing operation at low temperatures. The unit incorporates a welded steel chassis and is finished in an epoxy coating for resilience to damage caused by rough handling. KOMPACT OWNERS MANUAL Page 2 of 9

SPECIFICATIONS MODEL: 10240KP-US HEIGHT: 24.2 WIDTH: 20 DEPTH: 19.2 WEIGHT: 77.9 lbs AIRFLOW: 152 CFM POWER SUPPLY: 115V/ 60Hz/ 1 ph FINISH: Powder-coated Epoxy OPERATING RANGE: 33 F 105 F REFRIGERANT: R-22 (13 oz) KOMPACT OWNERS MANUAL Page 3 of 9

OPERATION The following procedures should be followed to test the Kompact for correct operation: 1. After unpacking, examine all external features to confirm damage-free shipment. Report all defects and damage at once. Connect the power cable to a grounded 15 Amp electrical outlet. 2. Check dehumidification process as follows: CAUTION: DO NOT REMOVE COVERS WHEN UNIT IS IN OPERATION. A. Place unit on a level surface. B. Start up unit by switching to ON. C. Check that the compressor is running. D. Leave the machine running for 15 minutes. E. Observe the evaporator coils through the rear upper grille, to confirm frost formation. i. If the air temperature is below 78 F, an even coating of frost should cover the entire evaporator coil. ii. If the air temperature is above 78 F, frost and/or droplets of condensed water should cover the entire evaporator coil. F. After continuous running time of approximately 55 minutes, unit will enter Hot Gas defrost mode for several minutes and then automatically return to normal operation. If, after carrying out the above procedures, the unit does not appear to function properly, refer to the Trouble Shooting section, which follows, or contact the Factory Service Center. CAUTION: Once the unit has been switched off, wait at least five minutes before restarting. After using the Kompact, turn it off for five minutes to allow the condensate on the coils to drain into the pump reservoir, then press the momentary pump purge switch for twenty to thirty seconds to evacuate the water from the pump reservoir. KOMPACT OWNERS MANUAL Page 4 of 9

ROUTINE MAINTENANCE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTENANCE ON ITEMS 1, 2, 4, 5, AND 6. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air. Hold the nozzle of the air hose away from the coil to avoid damaging the fins. Alternatively, vacuum clean the coils. WARNING: DO NOT STEAM CLEAN REFRIGERATION COILS. 2. Check that the fan is firmly secured to the motor shaft and that the fan rotates freely. The fan motor is sealed for life and therefore does not need oiling. 3. To check the refrigerant charge, run the unit for 15 minutes and briefly remove the top cover. The evaporator coil should be evenly frost coated across its surface. At temperatures above 78 F, the coil may be covered with droplets of water rather than frost. Partial frosting accompanied by frosting of the thin capillary tubes, indicates loss of refrigerant gas or low charge. During this inspection, check visually to ensure that the pump rollers are turning. 4. Check all wiring connections. 5. To check the operation of the defrost system, switch the machine on and leave it running for approximately 55 minutes. The machine will then enter Hot Gas defrost mode for approximately 5 minutes before returning to normal operation. If the unit will not defrost, the printed circuit timer board may be defective or the bypass valve may be inoperable. IF ANY OF THE PRECEDING PROBLEMS OCCUR, CONTACT THE EBAC SERVICE CENTER PRIOR TO CONTINUED OPERATION OF THE UNIT TO PREVENT PERMANENT DAMAGE. KOMPACT OWNERS MANUAL Page 5 of 9

REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a. The source of the leak must be determined and corrected. b. The machine should be thoroughly evacuated before recharging. c. The unit must be recharged with refrigerant measured accurately by weight. d. For evacuation and recharging of the machine, use the crimped and brazed charging stub attached to the side of the refrigerant compressor. The charging stub should be crimped and rebrazed after servicing. NEVER allow permanent service valves to be fitted to any part of the circuit. Service valves may leak causing further loss of refrigerant gas. 3. The refrigerant compressor fitted to the dehumidifier is a durable unit that should give many years of service. Compressor failure can result from the machine losing its refrigerant gas. The compressor can be replaced by a competent refrigeration technician. Failure of the compressor can be confirmed by the following procedure: a. Establish that power is present at the compressor terminals using a voltmeter. b. With the power disconnected, check the continuity of the internal winding by using meter across the compressor terminals. An open circuit indicates that the compressor should be replaced. c. Check that the compressor is not grounded by establishing that a circuit does not exist between the compressor terminals and the shell of the compressor. KOMPACT OWNERS MANUAL Page 6 of 9

TROUBLESHOOTING SYMPTOM Unit inoperative Little or no airflow Little or no water extraction Little or no defrost when required Unit vibrates excessively Water flooding inside the machine CAUSE 1. No power to unit 1. Loose fan on shaft 2. Fan motor burnt out 3. Dirty refrigeration coils 4. Loose electrical wiring 5. Fuse blown or circuit breaker tripped 1. Insufficient air flow 2. Compressor fault 3. Loss of refrigerant gas 1. Faulty timer 2. Faulty by-pass valve 1. Loose compressor 2. Damaged fan 1. Drain pipe blocked/frozen 2. Drain pipe too high 3. Crimped or blocked tubing REMEDY 1. Check the power from power supply panel 1. Tighten fan 2. Replace the fan motor 3. See Routine Maintenance Section 4. Check the wiring diagram to find fault and repair 5. Replace the fuse or reset the circuit breaker 1. Check all of the above 2. Contact the Factory Service Center 3. Contact the Factory Service Center 1. Contact the Factory Service Center 2. Contact the Factory Service Center 1. Tighten the nuts on the compressor mounts 2. Replace fan 1. Clear the obstruction 2. Ensure that no section of the drain hose is above the level of the water outlet 3. Straighten, clear, or replace tubing Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632 Website www.ebacusa.com KOMPACT OWNERS MANUAL Page 7 of 9

KOMPACT SPARE PARTS LIST NUMBER DESCRIPTION PART NUMBER QUANTITY 1 Filter 1019712 1 2 Timer 1600500 1 3 Evaporator Coil 2026013 1 4 Condenser Coil 2026014 1 5 Drain Tray 2131107 1 6 Capillary Tube 3014251 48 7 Solenoid Valve 3020814 1 8 Filter Dryer 3020901 1 9 Compressor 3022169 1 10 Solenoid Coil 3030421 1 11 Capacitor 3030908 1 12 Terminal Block 3031460 1 13 Fan Motor 3035788 1 14 Fan Blade 3040129 1 15 Fan Inlet Ring 3040326 1 16 Black Rubber Foot 3101436 2 17 Pump 3160143 1 18 GFI Plug 3934517 1 KOMPACT OWNERS MANUAL Page 8 of 9

LIMITED WARRANTY Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labor required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit. THE FOREGOING WARRANTY IS EXCLUSIVE AND IS ISSUED IN LIEU OF ALL OTHER WARRANTIES (WHETHER WRITTEN, ORAL, OR IMPLIED) INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. EBAC INDUSTRIAL PRODUCTS, INC. DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL DAMAGES, LOST PROFITS, OR INCIDENTAL DAMAGES FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE. For Your Records: Model: S/N: Date Received: SAVE THIS SECTION FOR YOUR RECORDS CLIP AND RETURN THIS CARD PLEASE NOTE To ensure that your Ebac Dehumidifier is accorded the full coverage provided by this warranty, please complete and mail this card at your earliest convenience. Thank You WARRANTY REGISTRATION DATE MODEL S/N RECEIVED OWNER ADDRESS CITY STATE ZIP COMMENTS Ebac Industrial Products. 700 Thimble Shoals Boulevard, Suite 109, Newport News, Virginia. 23606-2575 KOMPACT OWNERS MANUAL Page 9 of 9