Model 7611 Eye/Face Wash

Similar documents
Model 7656WCC Eye/face Wash

Model 8330 Stainless Steel Combination Shower Eye/Face Wash

Model /8300CRP-8309CRP Shower & Eye/Face Wash

Model 8356WCSM Pull-Down Shower Eye/Face Wash

Model /8320CRP Shower and Eye/Face Wash

Model 8356WCC Pull-Down Shower Eye/Face Wash

Model Combination Shower Eye/Face Wash

Model 8300FP Freeze Resistant Combination Shower Eye/Face Wash

Model 1920/1920HPS/1920W Bottle Filler

Model 9201EFE Tempered Water Blending System

Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model TWBS.EW.H Tempered Water Blending System

Model 1011/1011HPS Drinking Fountain

Model 9201EW Tempered Water Blending System

Model 9001, Alarm

Model TWBS.SHE Tempered Water Blending System

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model 7500EB Portable Eyewash with Heater

Model 9001, Alarm

Model 7501/7501T/7501TH/7501T240/7501T240H Portable Eyewash/Portable Eyewash with Heater

Model H1011.8/H1011.8HPS Water Cooler

Model 1900 Retrofit Bottle Filler

INSTALLATION & TESTING MANUAL

Model 7603BL/7603BL240 Heated Blanket for 7603 Portable Eyewash

3121FR Pedestal Mounted Drinking Fountain

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

model1119 with1920 ADA Compliant Dual Wall-Mount Fountain and Bottle Filler FEATURES & BENEFITS MODEL CHOICES SPECIFICATIONS OPTIONS

INSTALLATION & TESTING MANUAL

H Barrier-Free Wall Mounted Electric Drinking Fountain

H1011.8HPS Barrier-Free Wall Mounted Electric Drinking Fountain

Model 7603/7603T/7603T240 Portable Eyewash / Portable Eyewash with Heater

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

H Barrier-Free Wall Mounted Electric Drinking Fountain

model 1900 FEATURES & BENEFITS SPECIFICATIONS APPLICATIONS OPTIONS Bottle Filling Station

model 1900 FEATURES & BENEFITS SPECIFICATIONS APPLICATIONS OPTIONS Bottle Filling Station

SAFETY SHOWERS & EYEWASHES

MEGATRON MODEL 2NB-LF, 3NB-LF, 4NB-LF, 5NB-LF NEXT GENERATION MANIFOLD SYSTEMS TM-520B-LF, 820B-LF, 920B-LF, 1520B-LF

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

MEGATRON MODEL TA, TA-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

ADA Compliant Wall-Mount Fountain and Bottle Filler

30 R -10 C F H C INSTALLATION. Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water. CAUTION

8317CTFP AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER Freeze Resistant

model1117l with1920 ADA Compliant Dual Wall-Mount Fountain and Bottle Filler FEATURES & BENEFITS MODEL CHOICES OPTIONS SPECIFICATIONS

installation, operation & Maintenance manual Floor-mounted Induction units

Operation, Maintenance and Installation Manual

FFP S700 SERIES. Pull-Out Spray Faucet. Installation guide

INSTRUCTION MANUAL WARRANTY CERTIFICATE

Instant Hot Water Dispenser Owner s Manual

1/7 SPOUT INSTALLATION

Karbon Kitchen Sink Tap

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

MOJAVE. Mojave ShowerSpa Model #1016 Owner's Manual

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

MEGATRON MODEL 2N, 3N, 4N, 5N HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF, TM-820-LF, TM-920-LF, TM-1520A-LF

Installation Instructions / Warranty. Hansgrohe Single Control Kitchen Mixers

1.6 GALLON ONE PIECE TOILET

Oahu Showerspa Model #1035 Owner's Manual

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

America s Walk-In Tub. Installation & Instructions. Manufactured by. A Division of Spa World Corp NW 35th Avenue ANSI-Z124.1

PALARRE, ROCHELLE WATER-GUARD VITREOUS CHINA SIPHON JET TOILET

AN AXION TM EYEWASH...

Installation Instructions / Warranty

BARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327

WELLWORTH WATERGUARD VITREOUS CHINA SIPHON JET TOILET

INSTALLATION INSTRUCTIONS

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

Troubleshooting the MPH 24FP Series Pedestal Hydrant

Installation Instructions / Warranty. PuraVida 15775XX1

INSTALLATION INSTRUCTIONS. Cubix Widespread Faucet Part #: 3204, 5204, 3304, 5304 HANDLE STYLES

Please Read and Save These Instructions.

CONCEPT II WET BY. U.S. Patents: D478,654; D478,974; D478,980; 6,059,531; 7,008,192 INSTRUCTION MANUAL WARRANTY CERTIFICATE

Corrosion Resistant Fluid and Air Handling Systems.

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

Seda 8 Widespread 2-Handle Faucet

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

WATER POWERED OSCILLATING MONITOR

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

Duct Mount. Installation Instructions

Installation & Operation Manual Ice Cream Freezers

SP-Series Outdoor Microwave Radar Barrier User Manual

MERIDIAN MODEL# 3793

Read All Instructions Thoroughly Before Installing or Using the Disposer.

Aquila Single Lever Vessel Faucet

INSTALLATION INSTRUCTIONS

TITAN FLOW CONTROL, INC.

Installation Instructions Model: EB Single-Lever Lavatory Faucet

SPRINKLER ALARM TECHNICAL DATA SPRINKLER ALARM MODEL - GA

OPERATOR S MANUAL HWH HYDRAULIC SPACEMAKER ROOM EXTENSION SYSTEMS

Transcription:

INSTALLATION, OPEATION & MAINTENANCE INSTUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model Eye/Face Wash No. 2080063() NOTE TO INSTALLE: Please leave this information with the Maintenance Department. LIMITED WAANTY HAWS warrants that this specific product is guaranteed against defective material or poor workmanship for a period of one year from date of shipment. HAWS liability under this warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first class workmanship, provided that claim is made in writing to Haws within a reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be delivered to the Company, prepaid, for inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents, except upon written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated, except that of title with respect to any of the products or equipment sold hereunder and that HAWS shall not be liable for general, special, or consequential damages claimed to arise under the contract of sale. The emergency equipment manufactured by HAWS is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose for which they were intended. This product is intended to supplement first-aid treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this emergency equipment will prevent serious injury or the aggravation of existing or prior injuries. NO OTHE WAANTIES EXPESSED O IMPLIED AE AUTHOIZED, POVIDED O GIVEN BY HAWS. SHOULD YOU EXPEIENCE DIFFICULTY WITH THE INSTALLATION OF THIS MODEL PLEASE CALL: TECHNICAL SUPPOT: 1-800-766-5612 FO CUSTOME SEVICE: 1-888-640-4297 07/17 Model Page 1 of 5

LOCATION OF UNIT: The Model Eye/Face Wash should be installed in close proximity to potential accident areas. It should be clearly identified free from obstructions and easy to access. SUPPLY LINE: The minimum recommended line size is 1/2" IPS with 30-90 psi (2-6 ATM) flowing line pressure. Where sediment or mineral content is a problem, an inlet filter is recommended. PLUMBING CONNECTIONS: Inlet supply is 1/2" O.D. slip joint. TOUBLESHOOTING POBLEM EPAI CHECKLIST 1. No flow. 1. Check the main shut-off valve. 2. Insufficient water flow. 2. a. Verify minimum 30 psi flowing supply line pressure. b. Probable clogging of flow control due to inadequate line flushing. Unscrew eye/face wash head and remove the four screws to disassemble head. Clean flow control and reassemble head. 3. Eye/face wash stream does not meet desired eye level. 3. a. Possible blocked flow control, see above solution. b. Possible non-leveled eye/face wash assembly. INSTALLATION INSTUCTIONS efer to installation drawing to clarify installation procedure. Note: Model Eye/Face Wash can be mounted on either right or left side of the sink. For left hand use, reconfigure as shown on installation drawing. STEP 1: STEP 2: STEP 3: STEP 4: emove the 3" O.D. flange from valve body. emove the protective backing from rubber washer. After making sure that bottom surface of the counter top or deck, around the drilled hole is clean and free of grease, slide valve through drilled hole from the bottom. Place sign over valve. STEP 5: einstall the 3" O.D. flange, ensure that the top surface of flange is flush with valve. Wrench tighten locknut against base of counter or deck. STEP 6: Install eye/face wash assembly to valve and after checking for proper alignment, tighten the setscrew on the cap. 2017 Haws Corporation All ights eserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 07/17 Model Page 2 of 5

THIS DOCUMENT IS TUE AND COECT AT TIME OF PUBLICATION. CONTINUED PODUCT IMPOVEMENTS PATS BEAKDOWN ITEM DESCIPTION 1 E/F WASH AXION 2 VALVE ASSEMBLY 3 SWING AWAY SIGN 4 EYEWASH SIGN 5 TEST TAG EPAI KIT PAT NO. 0002953160-0005240025 SP175 SP170 VK7650 1 4 3 2 5 ECN NO. EVISED PE BY ECN: 5211 JP DAWN DATE CHKD EVISION STH /21/96 GC APPOVED DATE FV 08/09/17 SCALE: 1:1 DAWING TYPE: PATS BEAKDOWN SIZE: A SHEET 1 OF 1 WHEN ODEING PATS PLEASE SPECIFY MODEL NUMBE. C 2017 Haws Corporation - All ights eserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 0002080063 PAGE 3 of 5

THIS DOCUMENT IS TUE AND COECT AT TIME OF PUBLICATION. CONTINUED PODUCT IMPOVEMENTS 3-5/8" 92mm 1-5/8" 41mm MAX. DECK THICKNESS SINK (EFEENCE) 6"(152mm) MIN. CLEAANCE LEFT HAND MOUNTING LOCATION LOCKNUT VALVE CAP SET SCEW " 254mm OFF CLEAANCE ADIUS SET SCEW SUPPLY SHANK 1-3/4" 45mm 3-1/4" 83mm FLANGE SIGN IGHT HAND MOUNTING LOCATION UBBE WASHE & D-NOTCH WASHE 4-7/8" 124mm 1/2" O.D. SUPPLY (BY OTHES) SUPPLY SHANK CAN BE POSITIONED IN ONE OF FOU DIECTIONS 90 APAT BY LOOSENING THE CAP SET SCEW AND OTATING VALVE NOTES: 1. 2. 3. 4. MIN. CLEAANCE TO SINK EDGE LEFT HAND APPLICATION MOVE SET SCEW INDENTATION IN SPOOL FO CAP SET SCEW THE ANSI Z358.1-2009 STANDAD SPECIFIES EYEWASH NOZZLE HEIGHTS TO BE 83.8cm (33 IN.) TO 114.3cm (45 IN.) ABOVE THE FLOO INSTALL SO THAT EYEWASH HEAD IS OVE SINK WHEN ACTIVATED. DILL ONE Ø1-3/8" [35mm] HOLE WHEE UNIT IS TO BE INSTALLED. ±1/2" [6.4mm]. THESE DIMENSIONS MAY VAY FLIP OVE Left Hand ight Hand SIGN PAGE 4 OF 5 SEAL BASE WITH SILICONE CAULK (BETWEEN BOTTOM OF SIGN AND COUNTETOP) 5" 127mm MIN. CLEAANCE ADIUS FO FACEWASH STEAMS OPPOSITE SIDE AND 15.2cm (6 IN.) MINIMUM FOM WALL O NEAEST OBSTUCTION. C 2017 ECN NO. EVISED PE BY: 2065 ECN: 5211 JP DAWN: DATE: CHK'D.: STH /96 GC APPOVED: DATE: FV 08/09/17 EVISION SCALE: 8:1 DAWING TYPE: INSTALLATION SIZE: A SHEET 1 OF 2 Haws Corporation - All ights eserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 0002080063.D

THIS DOCUMENT IS TUE AND COECT AT TIME OF PUBLICATION. CONTINUED PODUCT IMPOVEMENTS SEAL BASE WITH SILICONE CAULK BE SUE TOP SUFACE OF FLANGE IS FLUSH WITH VALVE AS SHOWN BE SUE SIGN IS ON POPE SIDE BE SUE POTECTIVE BACKING IS EMOVED FOM UBBE WASHE D-NOTCH WASHE LOCKNUT C 2017 ECN NO. EVISED PE BY: ECN: 5211 JP DAWN: DATE: CHK'D.: STH /96 GC APPOVED: DATE: FV 08/09/17 EVISION SCALE: 1:1 DAWING TYPE: INSTALLATION SIZE: A SHEET 2 OF 2 Haws Corporation - All ights eserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation. 0002080063.D