SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

Similar documents
SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

CLOSED COUPLED CENTRIFUGAL PUMPS

FLANGE-MOUNT CENTRIFUGAL PUMPS

5. CONDENSATE PUMPS/UNITS

SERIES ES BASE MOUNTED TURBINE PUMPS

STAINLESS STEEL UNITS

POULTRY MARKET CATALOG

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series

DUPLEX CONDENSATE TANK SYSTEM

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Series SR Compact Centrifugal Mag-Drive Pumps. WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec

Full-line Product Overview

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

Wilo IL Vertical Split-Coupled Inline Pumps

DESCRIPTION MAINTENANCE INSTALLATION OF NEW SEAL REMOVAL OF OLD SHAFT SEAL

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

Hoffman Specialty Pump Products

OWNERS GUIDE TO INSTALLATION AND OPERATION END SUCTION CENTRIFUGAL PUMPS

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

TECHNICAL. Series 18. Pump Packages

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Industrial. Solutions brands you trust. Product Overview

OWNERS GUIDE TO INSTALLATION AND OPERATION

Intelligent Variable Speed Pump

FM 517 San Leon, TX Toll Free: Office: (281) Fax: (281)

Machine Tool Coolant Units

KEENER GRINDER PUMPS

Condensate Boiler Feed Water Make-Up

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SECTION STEAM CONDENSATE PUMPS

LINE OVERVIEW CATALOG

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

MARLOW PUMPS RECIRCULATION

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

SECTION STEAM CONDENSATE PUMPS

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

Family Curve. Submersible Grinder Pumps 1¼" and 2" Discharge. Effluent/Grinder Pumps.

SECTION FIRE PUMP AND CONTROLS

K4RH(X) Solids-Handling Pumps

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

MODEL 664A MODEL 662A MODEL 663A MODEL 661A AURORA. 660 Series SINGLE STAGE SOLIDS HANDLING VORTEX PUMPS

Reliable Long-Term Solutions For Your Toughest Pump

489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power

SUMP PUMPS, EFFLUENT PUMPS AND SEWAGE PUMPS

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Goulds Trash Hog. Self-Priming Solids Handling Pumps

America s Most Versatile Line of Centrifugal Pumps

Line Overview Catalog

470 Series Stamped Stainless Steel Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

GRUNDFOS PLUMBING & HVAC PRODUCTS

ACT-4 AC Electronically Commutated Spherical Motor Centrifugal Pump Kit

The Replacement Motor & Fan Specialists

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

1900 Series In-Line Pump

FEATURES. Other Fed-Flush Arrangements

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Family Curve. Submersible Grinder Pumps 1¼" and 3" Discharge. Effluent/Grinder Pumps.

SERIES 1600 Quality Design Features Assure Long, Trouble-Free Service

K4RB(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location)

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

Models Series Series

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Dewatering Pumps. Construction Starts Here. Centrifugal and Diaphragm Models.

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

MAGNETIC DRIVE PUMPS AMERICA S MOST VERSATILE LINE OF CENTRIFUGAL PUMPS THINK QUALITY...THINK DELIVERY...THINK PRICE

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

Dean Pump High Temperature Chemical Process Inline Pumps

Hard-hitting Contenders In HVAC Fluid Handling Solutions

TYPE VSM/VSMS VERTICAL SPACE MISER PUMPS

SMF PUMP OWNER S MANUAL

Taco 00 Series Cartridge Circulators

Item No. Name of Part Material of Construction 1 * 2 11 * * 65

Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective

dp pumps the dynamics of water HVAC centrifugal (norm) pumps

Models Series Series

Stainless Steel Condensate Return Units

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

dp pumps the dynamics of water HVAC centrifugal (norm) pumps

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

References are in agreement with UMRL dated April 2018 **************************************************************************

Transcription:

40 Third Street Piqua, Ohio 45356-0603 www.pumpagents.com PumpAgents.com - Click here for Pricing/Ordering SERIES: WT SECTION 4C PAGE ISSUED /04 REPLACES /03 SELF-PRIMING CENTRIFUGAL PUMPS For Water and Other.00 S.G. Fluids WT5 Series WT3A Series WT5X Series 60 HZ - PERFORMANCE AND SELECTION.00 FLUID S.G. - 3500 RPM Catalog Number HP TAPPINGS CAPACITY IN G.P.M. (L.P.S.) - TOTAL HEAD FEET (METERS) PHASE 3 PHASE SUCT. DISCH. 0 (3M) 5 (4.5M) 0 (6M) 5 (7.6M) 30 (.M) 35 (0.6M) 3 (.5M) A3WT3A* /3 " " 4 (.6) 40 (.5) 37 (.3) 33 (.0) 6 (.6) 7 (.0) (0.5) 3WT3A* 33WT3A* **Catalog number 5WT5 7WT5 0WT5 5WT5 0WT5 0WT5A **Catalog No. with strainer 5WT5X 7WT5X 0WT5X 5WT5X 0WT5X 0WT5AX HP TAPPINGS CAPACITY IN G.P.M. (L.P.S.) - TOTAL HEAD FEET (METERS) / 3/4 -/ SUCT. DISCH. 0 (3M) " " 55 (3.4) 7 (4.5) (5.) 6 (5.4) 4 (5.) 40 (.) 0 (6M) 4 (3.0) 70 (4.4) 7 (4.) 6 (5.4) 3 (5.) 40 (.) 30 (M) 43 (.7) 66 (4.) 76 (4.7) 4 (5.) (5.) 3 (.3) 40 (M) 37 (.3) 6 (3.) 7 (4.5) 0 (5.0) (5.6) (7.5) 50 (5M) 30 (.) 5 (3.) 65 (4.) 75 (4.7) 5 (5.3) (6.) 60 (M) (.3) 40 (.5) 54 (3.4) 67 (4.) 7 (4.) 70 (M) 0 (0.6) 4 (.5) 40 (.5) 54 (3.4) 67 (4.) 0 (4M) 0 (.) 3 (.3) 50 (3.) 0 (7M) (.) 30 (.) ** Catalog numbers are for units with single phase motors. For three phase, add prefix, "3". Example 35WT5X. * Maximum suction lift on WT3A - 7 ft. Maximum suction lift on WT5 series - 0 ft. A Crane Co. Company PUMPS & SYSTEMS

SECTION 4C PAGE ISSUED /03 REPLACES 4/0 40 Third Street Piqua, Ohio 45356-0603 SELF-PRIMING CENTRIFUGAL PUMPS Compact, Close-Coupled Design Rugged Bronze-Fitted Cast Iron Construction Leakproof Mechanical Shaft Seal Non-Clogging, Bronze Semi-Open Impeller Stainless Steel Shaft Back Pull-Out Design For Easy Servicing FEATURES Available With or Without Built-In Basket Type Strainer Self-Priming, Once Case is Filled With Fluid Diaphragms, Flappers or Check Valves Are Not Required In Pump Suction Piping. But Are Recommended EVERY pump is factory tested and will meet Hydraulic Institute standards. MOTOR INFORMATION WT3A Series have NEMA Jet Pump Motors. WT5 & WT5X Series have rugged Swimming Pool type motors with oversize ball/ball bearing construction. All motors have open-drip proof construction and are rated with standard NEMA Jet Pump service factors for continuous duty operation at all ratings shown. Voltages may differ from some suppliers. Consult factory. Overload Protection: All single phase motors have built-in overload protection. All three phase motors must be installed with a magnetic starter which provides full 3-leg protection. Failure to use correct starter and overloads will void motor warranty. All Single Phase Open Drip Proof Motors Are U.L. Recognized. RATINGS A3WT3A-/3 HP, Single Phase, 5V, 60Hz, 3500RPM, ODP, Split Phase. 3WT3A-/3 HP, Single Phase, 5/30V, 60Hz, 3500RPM, ODP, Capacitor Start. 33WT3A-/3 HP, Three Phase, 30/460V, 60Hz, 3500RPM, ODP WT5 & WT5X Series: Single Phase: / thru HP, 5/30V, 60HZ, 3500RPM, ODP, Capacitor Start. Three Phase: / thru HP, 30/460V, 60HZ, 3500RPM, ODP. MATERIALS OF CONSTRUCTION PART ALL BRONZE Adapter Cast Iron Case Cast Iron Impeller Bronze Diffuser Cast Iron Shaft Stainless Steel Shaft Seal Carbon-Ceramic-S. Steel-Buna-N Suction Sleeve Buna-N Strainer Gasket Buna-N Strainer Basket Stainless Steel All Plugs Brass MAXIMUM OPERATING CONDITIONS TEMPERATURE 5 F (07 C) (For Standard Buna-N Seal) INLET PRESSURE (WT3 & WT5) 00 PSI (60kpa) INLET PRESSURE (WT5X) 5 PSI (03kpa) CASING WORKING PRESSURE (WT3 & WT5) 65 PSI (37kpa) CASING WORKING PRESSURE (WT5X) 60 PSI (43kpa) PUMPS & SYSTEMS A Crane Co. Company

40 Third Street Piqua, Ohio 45356-0603 DIMENSIONS SECTION 4C PAGE 3 ISSUED /03 REPLACES /0 SERIES WT3A CATALOG A3WT3A 3WT3A 33WT3A DIMENSIONS IN INCHES SINGLE PHASE THREE PHASE 5 5 / 7 7 / 3 / 5 / 3 / DIMENSIONS IN MILLIMETERS CATALOG SINGLE PHASE THREE PHASE A3WT3A 3WT3A 33WT3A 3 33 00 33 All models have " NPT suction and discharge. SERIES WT5 CATALOG 5WT5 7WT5 0WT5 5WT5 0WT5 0WT5A DIMENSIONS IN INCHES SINGLE PHASE THREE PHASE 5 7 / 6 7 / 7 /4 3 / 0 / 0 / 0 / 5 5 / 6 7 / 6 7 / 6 7 / 7 /4 7 /4 7 3 /4 3 / 3 / DIMENSIONS IN MILLIMETERS CATALOG SINGLE PHASE THREE PHASE 5WT5 7WT5 0WT5 5WT5 0WT5 0WT5A 403 4 43 457 457 457 03 3 57 57 57 36 4 4 4 43 43 All models have " NPT suction and discharge. SERIES WT5X 6 3 3 CATALOG 5WT5X 7WT5X 0WT5X 5WT5X 0WT5X 0WT5AX DIMENSIONS IN INCHES SINGLE PHASE THREE PHASE 0 3 /4 3 /4 / 7 / 7 / 7 / 3 / 0 / 0 / 0 / 0 / 3 /4 3 /4 3 /4 / / 7 3 /4 3 / 3 / DIMENSIONS IN MILLIMETERS CATALOG SINGLE PHASE THREE PHASE 5WT5X 7WT5X 0WT5X 5WT5X 0WT5X 0WT5AX DO NOT USE FOR CONSTRUCTION PURPOSES. CERTIFIED DRAWINGS AVAILABLE ON REQUEST. 57 55 56 5 5 5 03 3 57 57 57 50 55 55 55 56 56 All models have " NPT suction and discharge. 6 3 3 A Crane Co. Company PUMPS & SYSTEMS

CSPP-6 NOTE: Impeller must extend from face of frame as follows: WT3 & WPT3-7/3" ± /64" WT3A & WPT3A - /3" ± /64" Shim washers (Symbol ) may be added or removed as required to obtain dimensions. SERIES: WT3, WT3A, WPT3, WPT3A SELF-PRIMING CENTRIFUGAL PUMPS File: WT3.dwg

SYMBOL PART QUANTITY DESCRIPTION SYMBOL PART QUANTITY DESCRIPTION 3 00 05 066 005 005-006 006- Motor, /3HP, 5V, PH Motor, /3HP, 530V, PH Motor, /3HP, 30/460V, 3 PH Adapter - WT3, WPT3 Adapter - WT3A, WPT3A Case Case w/priming Hole 0 Not Shown 0436 00 04 054-A 06 -C As req. As req. As req. Plug, /4- NPT Roll Pin, 3/6 x 3/4 Shim Washer -.00" Shim Washer -.03" Shim Washer -.06" Lock Washer, 3 Phase Lock Screw, 3 Phase 4 5 6 7 007-A 040-A-3 00 00-076 054 0 00 0535 000 Impeller - WT3, WPT3 Impeller - WT3A, WPT3A Diffuser- WT3, WPT3 Diffuser- WT3A, WPT3A Mechanical Seal - Viton - WPT Mechanical Seal - Buna N - WT Cap Screw, 3/-" Lg Suction Sleeve - Viton - WPT Suction Sleeve - Buna N - WT Gasket - Case to Adapter 4 0 Not Shown 007 040-3 0436-A -A * For hot water or caustic service. ALL IRON PARTS Impeller Impeller Plug Lock Washer, 3 Phase CSPP-63 SERIES: WT3, WT3A, WPT3, WPT3A * Series WT & WPT pumps have been manufactured with either cast iron or bronze impellers as standard. All replacement impellers will be bronze as listed, unless iron is specified. For iron impellers, omit the letter "A" from part number. EXAMPLE: 040-3.

For technical advice or service please take your pump into your local pump service center. To order pump or parts or for pricing please go to the following links : Burks Pumps Home >> Burks Pumps stock list >>