Expanded Backup Control Installation & Operator s Instruction Manual

Similar documents
CT2 Retro Box Installation Instruction Manual

TURBO Hooded Fans. Installation & Operator s Manual (14, 18, & 24 Direct Drive)

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

User's Manual H-VC5. Chore-Logic. H-VC5 User manual. Version HPS 11/11/2006 User manual 1.02 ST50737MA 3/07. Page 1

Chore-Tronics Load Cell Indicator

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

GENERATION 2 QUADRATHERM Heater

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

Spray Pad Evaporative Cooling

ion Genesis Pump Controller

High Pressure 120 Volt Direct Spark Ignition

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

16" and 20" Economy Incandescent Full Hoods Owner s Manual

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Integra Family. Operations Manual. Models: Integra TX SS, Integra HD, Integra DS, Integra DS LA, Integra UHS, Machine Name: Serial Number:

Instruction Manual. Carmel Apple-Dip Warmer

HotPoly Tote Tank / IBC Heaters (TTH Series)

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Air Pump Up to 800 gallons

DUST FREE CARBON Whole House Air Purifier

(HSTAT Series) Instruction Manual

IMPORTANT SAFETY INFORMATION

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

PLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

FOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:

DISCONTINUED VERSION The information in this manual is no longer current. OPERATING & SERVICE MANUAL

MaxLite LED Vapor Tight Linear Fixture

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

MaxLite LED MICRO-T PANEL

Instruction Manual. Double Candy Apple Cooker

Part No Revised January 30, 2007 SAFETY PRECAUTIONS

READ AND SAVE THESE INSTRUCTIONS

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

OPERATING MANUAL/ INSTALLATION

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

MaxLite LED Round Pendant Highbay Series

Humidistat-Thermostat

AUTOMATIC SWINGING DOOR

Instruction Manual. Part No Revised September 2004

TrueClean ToteCleaner

TrueClean ToteCleaner

Instruction Manual: IM E. Installation and Operation Manual for Powerware PVL 50, 80, 100, 120, 160, 200 KA

Quest Power Electric Heat EHS 62 Pro

Beacon 800 Gas Monitor Operator s Manual

Instruction Manual. Portion Cup Cheese Warmer

BIONAIRE HEATER. Instruction Leaflet. pure indoor living MODEL: BCH4130. Read instructions before operating. Retain for future reference.

SACKSAFOAM QUICK FILL OPERATIONS MANUAL 2019A

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

FOR EASY, FAST INSTALLATION AND FOR RESULTS

Please read and follow all instructions for usage and maintenance before operating the VACMASTER SV1 Immersion Circulator.

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

The Da-Lite Difference.

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

Horizontal Bottle Cooler Installation and Operation Manual

HAMILTON ELECTRIC STOVE HEATER MODEL EF-BLT01 / EF-BLT04 / EF-BLT07 / EF-BLT08 OPERATION MANUAL

Installation Instructions PP-AS20 Anti-Scale System

FAN-FORCED UTILITY HEATER

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit

Spa Control System OWNER S MANUAL

Models: SV1 (110V) SV1EU ( V) User s Manual. Register your product and get support at. v

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

R Series B & T2 Model

Cheese Display Case. Instruction Manual Model #5580BV2 and Model #5580BV3 Model #5582 and Model #5583. Cincinnati, OH USA.

MODEL HBX-1 P/N 3G59332

ELECTRIC FIREPLACE OWNER S MANUAL

FLCH4R Garage and Utility Electric Heater

SEALING FIBER SEALING COMPOUND

TORRID MARINE YACHT QUALITY Since Owner s Manual

OmniDry 2.9 Amp Centrifugal Air Mover

Instruction Manual. Nacho Cheese Dispenser and Warmer

ELECTRIC FIREPLACE INSTRUCTION MANUAL. Item No: 050-HA Model No. FP405R-QA

FEED SYSTEM OPERATING INSTRUCTIONS THIS SHOULD NOT BE REFERENCED FOR INSTALLATION OR MAINTENANCE

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

To get started, please read and follow all instructions for usage and maintenance carefully before operating the VACMASTER BS116 Impulse Bag Sealer.

Safety, Installation, and Operation Manual

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

Surna 25-Ton Chiller Operating & Maintenance Manual

Instruction Manual. Cheese Warmer with Pump

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater

Embedded Linux with VAR-SOM-MX6 Course

Instruction Manual. Astro Staging Cabinet

IMPORTANT SAFETY INFORMATION:

Operating Instructions (ENG) MODEL: AM115V. Read instructions before operating the machine. AM /24/00

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

Transcription:

Installation & Operator s Instruction Manual March 2004

CTB Inc. Warranty CTB Inc. Warranty CTB Inc. warrants each new Chore-Tronics product manufactured by it to be free from defects in material or workmanship for one year from and after the date of initial installation by or for the original purchaser. If such a defect is found by the Manufacturer to exist within the one-year period, the Manufacturer will, at its option, (a) repair or replace such product free of charge, F.O.B. the factory of manufacture, or (b) refund to the original purchaser the original purchase price, in lieu of such repair or replacement. Labor costs associated with the replacement or repair of the product are not covered by the Manufacturer. Conditions and Limitations 1. The product must be installed by and operated in accordance with the instructions published by the Manufacturer or Warranty will be void. 2. Warranty is void if all components of the system are not original equipment supplied by the Manufacturer. 3. This product must be purchased from and installed by an authorized distributor or certified representative thereof or the Warranty will be void. 4. Malfunctions or failure resulting from misuse, abuse, negligence, alteration, accident, or lack of proper maintenance shall not be considered defects under the Warranty. 5. This Warranty applies only to systems for the care of poultry and livestock. Other applications in industry or commerce are not covered by this Warranty. The Manufacturer shall not be liable for any Consequential or Special Damage which any purchaser may suffer or claim to suffer as a result of any defect in the product. Consequential or Special Damages as used herein include, but are not limited to, lost or damaged products or goods, costs of transportation, lost sales, lost orders, lost income, increased overhead, labor and incidental costs and operational inefficiencies. THIS WARRANTY CONSTITUTES THE MANUFACTURER S ENTIRE AND SOLE WARRANTY AND THIS MANUFACTURER EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES, INCLUDING, BUT NOT LIMITED TO, EXPRESS AND IMPLIED WARRANTIES AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES SOLD AND DESCRIPTION OR QUALITY OF THE PRODUCT FURNISHED HEREUNDER. Chore-Tronics Distributors are not authorized to modify or extend the terms and conditions of this Warranty in any manner or to offer or grant any other warranties for Chore-Tronics products in addition to those terms expressly stated above. An officer of CTB, Inc. must authorize any exceptions to this Warranty in writing. The Manufacturer reserves the right to change models and specifications at any time without notice or obligation to improve previous models. Effective: May 2004 Thank You CTB Inc. P.O. Box 2000 Milford, Indiana 46542-2000 U.S.A. Phone (574) 658-4101 Fax (877) 730-8825 Email: ctb@ctbinc.com Internet: http//www.ctbinc.com The employees of CTB Inc. would like to thank your for your recent Chore-Tronics purchase. If a problem should arise, your Chore-Tronics distributor can supply the necessary information to help you. 2

Contents Topic Page User CTB Inc. Warranty.................................................. 2 General............................................................. 4 Support Information.......................................................... 4 Safety Information................................................... 4 Follow Safety Instructions..................................................... 4 Decal Descriptions........................................................... 4 DANGER : Electrical Hazard.................................................. 4 Introduction to Control............................................... 5 Thermostat functions......................................................... 6 Thermostat 1............................................................... 6 Thermostats 2, and 3......................................................... 6 Thermostats 4, and 5......................................................... 6 Switch Stickers.............................................................. 7 Thermostat Temperature Settings............................................... 7 Wiring Diagrams.................................................... 8 Thermostats & Inlet Wiring.................................................... 8 Relay Wiring............................................................... Internal Wiring #1........................................................... 10 Internal Wiring #2 (Thermostat and Toggle Switch)................................. 11 Part Numbers............................................................... 12 C C C,I C C,I * Legend: C = Customer (end user), D = Distributor (sales), I = Installer of equipment 3

General General Support Information The Chore-Tronics is used to provide a backup system for an electronically controlled livestock or poultry facility. Using this equipment for any other purpose or in a way not within the operating recommendations specified in this manual will void the warranty and may cause personal injury. This manual is designed to provide comprehensive planning, installation, safety, operation, and parts listing information. The Table of Contents provides a convenient overview of the information in this manual. The Table of Contents also specifies which pages contain information for the sales personnel, installer, and consumer (end user). Safety Information Caution, Warning and Danger Decals have been placed on the equipment to warn of potentially dangerous situations. Care should be taken to keep this information intact and easy to read at all times. Replace missing or damaged safety decals immediately. Using the equipment for purposes other than specified in this manual may cause personal injury and/or damage to the equipment. Follow Safety Instructions Carefully read all safety messages in this manual and on your equipment safety signs. Follow recommended precautions and safe operating practices. Keep safety signs in good condition. Replace missing or damaged safety signs. Decal Descriptions DANGER : Electrical Hazard Disconnect electrical power before inspecting or servicing equipment unless maintenance instructions specifically state otherwise. Ground all electrical equipment for safety. All electrical wiring must be done by a qualified electrician in accordance with local and national electric codes. Ground all non-current carrying metal parts to guard against electrical shock. With the exception of motor overload protection, electrical disconnects and over current protection are not supplied with the equipment. 4

Introduction to Control Introduction to Control The Chore-Tronics Expanded Back-up Control contains relays that are pre-wired for use with Backup Thermostats (Not Supplied). These relays are sized to conduct the actual motor current in one line of the power to the Fans being backed up. Each Relay can have a maximum of two independent 1hp loads wired to it. Each Output Relay is wired to a Toggle Switch (Item 1, Figure 1). The Toggle Switch allows the user to determine whether or not a fan or fans should turn on when the back up thermostat that the fan is connected to turns on. There is also a toggle switch that allows the user to determine if the Tunnel Curtain or the Sidewall Air Inlet Doors open when Thermostat 1 turns on (Item 2, Figure 1). 1 2 Item Description 1 Toggle Switch (Fans) 2 Toggle Switch (Tunnel Curtain, Sidewall Inlets) Figure 1. Toggle Switches 5

Introduction to Control Danger! Never place all of the Toggle Switches associated with any one Thermostat in the "Not Active" position. This will result in no Fans or Heat Zones turning on when the Backup Thermostat turns on. Thermostat functions The can have a maximum of 5 Backup Thermostats connected to it. Thermostat 1 When Thermostat 1 turns on, or if the 24Vdc (Volts direct current) of the electronic climate control is lost, a maximum of four independent 1 Open hp loads will turn on. Also, Tunnel depending on the position of the Inlet Toggle Switch, (Item 2, Figure 1), either the Tunnel Curtain or the Sidewall Inlet Doors will be given a continuous open signal while the close signal from the climate control will be blocked. Thermostats 2, and 3 Thermostats 2 and 3 will each turn on up to six independent loads. Thermostats 4, and 5 Thermostats 4 and 5 are used to back up heat zones. Each Thermostat can turn on up to 4 one HP independent heat zones each. 6

RESET THERMOSTATS WHENEVER SET TEMPERATURE IS CHANGED Introduction to Control Switch Stickers Remove the appropriate Switch Stickers (Item 1 Figure 2) from the Sticker Sheet, and stick them on the front of the Control in the space provided to identify what Fans or Heat Zones are wired to each Relay. 1 Exh Fan Tun Fan Tun Fan Ht Zone Ht Zone 1 5 1 5 13 13 & & Exh Fan Tun Fan Ht Zone 1 5 13 & Exh Fan Tun Fan Ht Zone 2 6 10 14 & Exh Fan Tun Fan Ht Zone 2 6 10 14 & TM Chore-Tronics THERMOSTAT 1 THERMOSTAT 2 NOT OPEN TUNNEL INLET OPEN INLET DOORS NOT EXPANDED BACKUP CONTROL Exh Fan Tun Fan Ht Zone 2 6 10 14 & Exh Fan Tun Fan Ht Zone 3 7 11 15 & Exh Fan Tun Fan Ht Zone 3 7 11 15 & Exh Fan Tun Fan Ht Zone 3 7 11 15 & Exh Fan Tun Fan Ht Zone 4 8 12 16 & Exh Fan Tun Fan Ht Zone 4 8 12 16 & Exh Fan Tun Fan Ht Zone 4 8 12 16 & 2 NOT NOT NOT 252-73 THERMOSTAT 3 THERMOSTAT 4 NOT NOT NOT NOT NOT CAUTION! 3 Item Description 1 Front of the Control 2 Switch Sticker Sheet 3 Switch Sticker NOT NOT NOT Exh Fan NOT Exh Fan Figure 1. Switch Stickers Danger! Thermostat Temperature Settings As with all backup systems that depend on mechanical Thermostats, it is essential that the temperature settings of the Thermostats be adjusted close enough to the set temperature to protect the livestock or poultry. Every time the set temperature of the electronic control is changed, the Backup Thermostats must be adjusted appropriately. Do not cross phase. The other leg of the power to the motors goes directly to the motors. The 24 VDC Input of this Back-up Box is meant to be connected to the 24 VDC output of the control being backed up. 7

Wiring Diagrams Wiring Diagrams Thermostats & Inlet Wiring I/O Board 24V From Control's Control Sidewall Inlet Open Close Tunnel Curtain Open Close L1 To Sidewall Inlet OPEN L1 To Sidewall Inlet CLOSED L2 To Sidewall Inlet L1 To Tunnel Curtain OPEN L1 To Tunnel Curtain CLOSE L2 To Tunnel Curtain L1 L2 L1 L2 L1 L2 Sidewall Inlet Circuit Breaker Tunnel Curtain Circuit Breaker Backup Box Circuit Breaker 24V GND 3 4 5 6 7 8 10 L1 L2 From Control's I/O Board Input Power 1 2 3 4 5 6 7 8 10 11 12 Thermostat Thermostat #4 Heat #4 Heat Thermostat #4 Heat Thermostat #4 Heat Figure 2. Thermostats and Inlet Wiring Thermostat #4 Heat 8

Wiring Diagrams Relay Wiring Relay Example (or Heat Zone 1) L1 From Circuit Brkr of Fan 1 (or Heat Zone 2) L1 From Circuit Brkr of Fan 2 L1 To Fan 1 (Or Heat Zone 1) L1 To Fan 1 (Or Heat Zone 1) Figure 3. Relay Wiring Thermostat #1 Relays Thermostat #4 Relays Thermostat #5 Relays Thermostat #2 Relays Thermostat #3 Relays

Internal Wiring #1 Figure 4. External Wiring #1 Wiring Diagrams 10

Figure 5. External Wiring #2 Internal Wiring #2 (Thermostat and Toggle Switch) Wiring Diagrams 11

Wiring Diagrams Part Numbers 1 3 7 8 6 5 4 Item 1 2 3 4 5 6 7 8 10 Description 14 x 16 Electric Box 14 x 16 Electric Box Lid (Not Shown) Switch Decal 12 Pole Terminal Strip 3 Terminal TA Relay 220 VAC Relay Toggle Switch SPST Toggle Switch Expanded Backup Top Plate Bottom Plate Part No. 42684 42683 252-73 3425 4250 34702 6014 48173 48120 48121 3 10 Figure 6. Part Numbers 12

Wiring Diagrams This Page Left Blank for Notes: 13

Wiring Diagrams Revisions to this Manual Page No. Description of Change New Book Contact your nearby Chore-Tronics distributor or representative for additional parts and information. CTB Inc. P.O. Box 2000 Milford, Indiana 46542-2000 U.S.A. Phone (574) 658-4101 Fax (877) 730-8825 E-Mail: ctb@ctbinc.com Internet: http//www.ctbinc.com Printed in the U.S.A. 14