Savings and performance worth celebrating! The DHP-AQ new air source heat pump from Danfoss

Similar documents
Planning guide. Atec.

DHP-H Opti Pro+ Ground Source Heat Pump Innovative and incomparable efficiency

Technical description. Atec.

User manual DHP-AQ VUGFB102

High temperature air-to-water heat pumps

Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating

HVAC Water chiller selection and optimisation of operation

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Technical data. Danfoss DHP-A

HT V2 HT Split

Installation instructions Danfoss heat pump DHP-R

LZT High efficiency air to water heat pumps with E.V.I. compressors

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

THE HEAT PUMP CHOICE OF PROFESSIONALS

Sweden s leading air source heat pump

Galletti Water chillers and heat pumps catalogue

HYDRONIC RESIDENTIAL

USER MANUAL. Danfoss Heat Pump DHP-R VUIFK102

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N


User Guide. itec.

DHP-H Varius Pro+/DHP-L Varius Pro+

Outdoor Condensing Unit - ZX Range. High Efficiency In Compact Design

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Neosys Product catalogue

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Technical data. Danfoss DHP-L

GEYSER kw. General information. Unique selling points

35% Ultra-efficient brazed heat exchangers for your district energy applications. Up to. Brazed Micro Plate heat exchangers

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

ECOFOREST GEOTERMIA. ecogeo. Ground/Air Source Heat Pumps.

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Compact and silent Scroll compressors All-season operation

HYDROCIAT LW R407C. Water cooled chillers USE RANGE


CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

Air-Cooled Condensing Units with Compact Screw Compressors

Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Advance Split

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

AQUASNAP JUNIOR 30RHV

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

50A KP 70A KP 90A KP 120A KP 150A KP 210A

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

With the world-renowned SIGMA PROFILE

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

30RH B Nominal cooling capacity kw Nominal heating capacity kw

500 EX Fusion Compressor Series

Contact-Cooled Rotary Screw Air Compressors. R-Series kw ( hp)

NIBE SPLIT ACVM 270 Air/water heat pump

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

UK-specific appendix to Installation instructions DHP-A DHP-A Opti DHP-AQ Maxi DHP-H DHP-H Opti DHP-H Opti Pro DHP-L DHP-L Opti DHP-L Opti Pro

LIQUID CHILLER HEAT PUMP kw 30RB/30RQ - R410A. A Multi-Talented Performer

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro+ DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro+

EN aquatech.piovan.com

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Starting current with soft starter Fuse protection

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

MAKING MODERN LIVING POSSIBLE. Installation Guide DHP-M.

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES


HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

Air-to-water scroll chillers

H4T R410A. refrigerant

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

1

Stationary screw compressors. Catalog #2

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

HEAT PUMPS FOR HEATING AIR-TO-WATER

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

Comfortable indoor climate regardless of the season

EHPA Testing Regulation

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

COMPACT ADSORPTION CHILLERS WITH COATED ADSORBER HEAT EXCHANGERS

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

THE CARRIER COMFORT LINE

THE HEART OF YOUR COMFORT

LZT High efficiency air to water heat pumps with E.V.I. compressors

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

LZA High efficiency air to water heat pumps with HP compressor

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Transcription:

Technical article Savings and performance worth celebrating! The DHP-AQ new air source heat pump from Danfoss Air source heat pumps are growing in popularity, thanks to the use of the latest innovations and technology, which means they are more efficient than ever before. When they were first introduced in Europe, some 10 years ago, their Coefficient of Performance (COP) was much less than manufacturers and homeowners would have liked when compared with their ground source equivalent. heating.danfoss.com

There was also the problem of air-source heat pumps generating noise outside buildings, which could cause problems in residential areas. A further challenge was the perception of potential customers who found it hard to believe that heat could be extracted from the air during freezing winter weather. Addressing the challenge In April this year, Danfoss Heat Pumps introduced the new DHP-AQ air-source heat pump onto the market. During the design and development stages, the objectives were as follows: 1. Achieve high annual efficiency. measured by seasonal performance factor (SPF); 2. Reduce emitted sound to a minimum; 3. Simplify installation. Core Technology The key factors influencing heat pump performance are use of the proper refrigerant, combined with a wellengineered and optimised refrigerant circuit, which means that the maximum amount of heat can be extracted from the air. This is why R407C was chosen as the refrigerant for the new pump, as it has the best trade-off between evaporation and condensation temperature, coupled with a low operating pressure. The heart of the pump cooling system is the dedicated scroll compressor. The compressor is optimised for dedicated heat pump applications. Its benefits are: high capacity at low evaporating (heat source) temperatures, when compared to piston-type compressors; this can result in lesser supplementary heating, has a special scroll design, which attains high efficiency in heat pump operating conditions, especially when the heat source temperature is low. The compressor s efficiency tends to increase over time, whereas most reciprocating compressors tend to lose some efficiency, the scroll is durable and reliable. Fewer moving parts, rugged running gear and low vibration due to balanced compression mechanism make the scroll the most reliable solution available on the market, the compressor also has a larger operating envelope than the air conditioning scroll, which allows it to match exactly the dedicated heat pump operating conditions. There is an electronic expansion valve applied in the refrigerant circuit which adjusts performance characteristics to the variable air temperature. Air temperature varies throughout the day, especially during the winter months, when conditions are immediately followed by a change in the amount of heat which needs to be supplied to the building. The electronic expansion valve delivers precise doses of refrigerant to the evaporator, and thus optimises the compressor performance to changing outdoor air temperatures, this air being the primary energy source for the heat pump. The changing temperature of the air being drawn across the evaporator has an effect on refrigerant evaporation pressure and consequently the possibility of appearing after evaporator vapours and liquid refrigerant mixture. The electronic expansion valve allows superheating of vapours at the right level in all conditions, and ensures a more effective use of the heat source, thus lowering the system thermal inertia and enabling higher control precision of the whole system. An important part of ensuring the efficiency of the DHP-AQ heat pump refrigeration system is that it is filled with refrigerant and hermetically sealed in the factory. Each heat pump is tested at the end of its production cycle and marked with an individual serial number. A further innovation which increases the efficiency of the system is the application of OPTI technology, which involves running an electronicallycontrolled circulating pump (class A) on the heat distribution side. 8 1 2 9 3 10 4 5 6 11 12 13 14 7 Figure 1,2: The DHP-AQ air source heat pump front side and components: 1) electrical cabinet, 2) fan,3) pressure transmitter, 4) compressor 5) high pressure switch, 6) operating pressure switch, 7) four-way valve, 8) air heat exchanger, 9) electronic expansion valve, 10) reciever, 11) drying filter, 12) heat exchanger, 13) supply line heating system, 14) return line heating system - 2 -

Acoustic performance Noise from air source heat pumps has been a recurring problem in many European countries, and one that has been addressed with the DHP-AQ. The DHP-AQ is designed to minimise: compressor vibration and noise levels, the noise level of the variable speed EC fan which forces air flow through the evaporator, noise levels across all operational modes. In heat pumps with a lower noise output, this is produced by the operating compressor as well as the EC fan (air flowing through fan blades and heat exchanger- evaporator ducts). However in the 16kW and 18kW units, the dominating noise source is the fan. With the DHP-AQ heat pump, an electronically operated motor is used to run the fan, and the fan blades also feature an innovative design to keep noise levels to a minimum. The pump s electronic motor has a reversed electromagnetic circuit, so that permanent magnets are part of the rotor and stator windings surround it. This ensures better rotor balance and increases the life of its bearings. This design also ensures that the motor has a higher rotational speed, and makes it possible for the unit to be reduced in size. The EC motor does not generate significant EMC emissions and is not the main source of noise caused by acoustic vibrations, since there is a special winding element placed inside which eliminates cyclic variations of motor torque resulting from the pulsatory changes of the magnetic field rotor. While installed in the DHP-AQ heat pump, the EC motor provides fluent control of the fan s rotational speed, a low noise level and high efficiency at relatively low power consumption levels. Another innovation in the applied fan is the HyBlade technology which has been adapted from aircraft engine design. The fan blades are made of plastic, with an aerodynamic shape and moulded edges which form winglets on the blade tips. These winglets minimise turbulence between the blade and the housing, making the fan quieter and more efficient. The blades are also resistant to corrosion, salt, humidity and chemicals, which is especially important if the heat pump is to be installed near the sea. Because the speed of the circulating pump is automatically adjusted according to the varying heat demand within the building, the condenser performance is optimised, which increases the system s efficiency. Plug & Play - simple installation The DHP-AQ has been designed to make both its hydronic and electrical connections as simple as possible to install. The pump consists of two components: a heat pump installed outdoors, and an indoor module including a control panel. The DHP-AQ heat pump takes heat from the air which is forced through one of the heat exchangers so as to maintain adequate air flow. When deciding on the location of the heat pump, it is important to ensure adequate space around the unit. If the pump unit is too close to the building the air may recirculate between intake and outlet, reducing the efficiency of the pump. Installers should also allow enough space to provide access to the unit for future servicing and maintenance. The DHP-AQ heat pump must be fixed on a firm foundation, for example a concrete base. Each of the four pump fastening points should be stably anchored in the foundation, and the load capacity of the foundation should be adjusted to the heat pump unit s overall weight. The outdoor unit is connected to the heating installation in the building by supply and return copper pipes, which should be 28mm in diameter. Heat hoses should be used to connect the DHP-AQ to the heating circuit in order to eliminate vibration transmission. An internal electric cabinet Figure 3,4,5: Components of indoor units: Mini, Midi, Maxi: 1) control module, 2) auxiliary heater, 3) reversing valve., 4) circulation pump, 5) water heater - 3 -

with output terminal strip is located on the outdoor unit (on the top left hand side) to allow for installation. The power should be connected to the heat pump unit and to the control panel located in the building. The control panel and heat pump must be connected by means of a three-core electric cable. Air source heat pumps will create condensed water, the amount of which will vary depending on outdoor air temperature and humidity. Condensed water from the evaporator drops into a tray which is supplied with the pump, and from there it flows through the tray outlet and flexible hose, which should be connected to the tray outlet, either into well-drained ground or the sewage system. A special 1mm diameter heating cable is built into the tray bottom to prevent freezing, and the outlet pipe should also be provided with a self-regulating heating cable and connected to the electric cabinet within the heat pump unit. Defrosting is automatically controlled by a temperature sensor, and lasts as long as it is required to defrost the evaporator. In case of system failure, adequate frost protection for the circulating fluids must be provided. The application of innovative technology makes the DHP-AQ heat pump one of the most efficient and quietest in terms of running noise on the market. The use of prefabricated kits rather than the separate components common in other air source pumps can save installers up to six hours on site. Options available The DHP-AQ air-source heat pump can supply space heating and hot water, and can also be used to cool buildings as an all-in-one application for every season. It is available in three sizes: Mini, Midi and Maxi. These three different pump sets and new controller functions ensure that the DHP-AQ heat pump can be used in over 50 different heating applications. When the heating system is modernised, the pump can co-operate with a gas boiler, oil boiler, solar system and private water source. Individual sets have been carefully selected and prepared so as to reduce the installation requirements to a minimum. Air-source heat pumps are available with the following power outputs: 6 kw, 9 kw, 11 kw, 13 kw, 16 kw, 18 kw. It is possible to connect two pumps to one control module, which enables pumps to be installed in buildings where total heat demand may rise up to 36 kw, such as schools or hotels. The pump operates efficiently even when outdoor air temperatures drop as low as -20 C, enabling customers to benefit from low energy costs even in the harshest winter conditions. The low noise levels mean less disturbance, which can also help with securing planning permission. In addition, the TWS (tap water stratification) system offered in the Maxi set enables quick and effective supply of hot water. The pump demonstrates the best in Scandinavian design. As air-source heat pumps are normally installed near to the house or commercial property, Danfoss designers were keen to enhance the aesthetics of the heat pump. The result is an air source heat pump with a sleek modern appearance to suit the needs of today s customers. Indoor kit Components Investment type Mini Heat pump, controller Modernization Midi Heat pump, controller, circulation pump (class A), auxiliary heater (400V - 3/6/9/12/15 kw; 230V - 3/6/9 kw), three way valve Modernization Maxi Heat pump, controller, hot water tank (180 l), circulation pump (class A), auxiliary heater (400V - 3/6/9/12/15 kw; 230V -3/6/9 kw), three way valve New Modernization or investment Maxi Midi Mini Figure 6: Indoor kits: Mini, Midi, Maxi - 4 -

3 wires communication cable Electricity supply Electricity supply Figure 7: Simple electrical installation 5 Heat pump unit 10 Supply line 11 Return line 12 Cold water 13 Hot water 18 Water heater 21 Buffer tank 33 Circulation pump shunt group 36 Circulation pump 40 Control unit 50 Outdoor sensor 51 Supply line sensor 52 Return line sensor 53 Hot water sensor 55 Peak temperature sensor 62 Room sensor 63 Shunt valve 64 Supply line sensor shunt group 71 Flow sensor 77 Switching valve for hot water 80 Shut-off valve 83 Non-return valve 85 Bleed valve 87 Safety valve (9 bar) 91 Strainer 96 Flexible hose 100 Safety valve (1.5 bar) 112 Expansion vessel, closed 114 Auxiliary heat System solution with DHP-AQ Maxi. DHP-AQ Maxi includes the control module with supply and return pipe sensors, circulation pump, 3-way valve, electric auxiliary heater and water heater. The heat pump produces heat, cooling and hot water. The production of heating and hot water cannot occur at the same time because the exchange valve for heating and hot water is positioned after the heat pump and the auxiliary heater. Hot water production is prioritised ahead of heat and cooling. Two heating circuits can be connected, one using a shunt. The shunt is controlled by the heat pump control system. The flow line temperature is controlled with reference to the outside temperature following a set heat curve. The additional heater starts automatically on demand. The auxiliary heater carries out peak heating charging (anti-legionella function) in those operating modes that permit auxiliary heat. A buffer tank is installed for the equalisation of the temperature for the heating system and to guarantee sufficient energy when defrosting. The buffer tank volume must be 10 l/kw heat pump output (for systems with water heaters). Danfoss A/S DK-6430 Nordborg Denmark Tel.: +45 74 88 22 22 Fax: +45 74 49 03 95 E-mail: heating@danfoss.com heating.danfoss.com Danfoss assumes no responsibility for any errors found in the catalogues, brochures and any other printed material. Danfoss retains the right to make changes to their products, including products that have already been ordered, without prior notice, as long as these changes can be carried out without changing predetermined specifications. All trademarks in this material belong to respective companies. Danfoss and the Danfoss logo are trademarks that belong to Danfoss A/S. All rights reserved. VQ.JS.B1.02_Sep2014-5 -