Samsung SDS BMS Ver.2.0. Technical Specification

Similar documents
HikCentral Web Client. User Manual

HikCentral Web Client. User Manual

VTScadaLIGHT for Small Water & Wastewater Systems

Advanced Facility Air-Management Technology

Using ANM Mobile CHAPTER

Smart Wireless Sensor

Patriot Systems Limited

Smart Wireless Sensor

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

Desigo Control Point The embedded building management station

Experion LX Direct Station Specification

Avigilon Control Center 5 System Integration Guide

Patriot Systems Limited

Perimeter Product Overview. Effective protection for your business

BMS Specification. Lonix Ltd.

PotterNet Fire & Facility Supervising Station

PcVue Solutions. PcVue Solutions

NETx Voyager Visualization

DeltaV Analyze. Introduction. Benefits. Continuous automated DeltaV System alarm system performance monitoring

Pharmagraph. envigil-fms Environmental Monitoring System

Climate Management and Control

Simplex Panel Interface Guide

THE EDDY IQ METER PRODUCT MANUAL

Architectural and Engineering Specification for a Security Management System. StarNet 2

CompleteView Alarm Client User Manual. CompleteView Version 4.6.1

Compact Product Suite Compact HMI 6.0 Overview ABB

Building Technologies

DR Series Appliance Cleaner Best Practices. Technical Whitepaper

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

IndigoVision Alarm Panel. User Guide

Tech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5)

DeltaV Operate. DeltaV Operate. Introduction. DeltaV Product Data Sheet. Robust and secure plant operations

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat

DeltaV Analyze. DeltaV Analyze. Introduction. DeltaV Product Data Sheet. Continuous automated DeltaV System alarm system performance monitoring

Monitoring Operator Guide. Access Control Manager Software Version

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

Lighting Xpert Insight User Manual

Datasheet Crowd Management

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0

i-vu CCN 4.0 Owner s Guide

Ion Gateway Cellular Gateway and Wireless Sensors

Avigilon Control Center 5 System Integration Guide

GMS GRAPHICAL MANAGEMENT SYSTEM

OnGuard 7.2 Resolved Issues

Netbiter Tank Sensor

REMOTE MONITORING AND ALARM SYSTEM

ARGUS SERVER SYSTEM. Inspired Systems Pty Ltd 70 Mordaunt Circuit, Canning Vale, Western Australia Ph Fax

Automation and Energy Efficiency of Industrial Refrigeration Systems

SAUTER EY-modulo 5. The complete building management solution.

Table of Contents. i-vu CCN Standard 4.2

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

ADRIA intelligent room system

NOV Wireless Lighting Controls for. Parking Garage. Bright and Secure Lighting MAPS MAPS TM

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

SAUTER EY-modulo 5. The complete building management solution

Procidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010

Oracle Retail Merchandising System Release Notes Release 12.0 May 2006

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

Introduction. Introduction

Avigilon Control Center System Integration Guide

Gallagher Perimeter Product Overview

Secure Your Way of Life. Now Compa ble With. Climax Home Portal Platform. Enable a Connected Future

Oracle Communications Performance Intelligence Center

ACTIVE INFRARED BARRIER

PSM CONTROL & MANAGEMENT PRODUCT CATALOGUE. GAMATRONIC, A SolarEdge Division. 17 Hartom Street, Jerusalem , Israel

DeltaV Live. Introduction. Benefits. Modern, built-for-purpose operations experience

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide

BlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7.

CODE ALERT Enterprise Software User Guide

LYNX CE CENTRAL CONTROL FOR OSMAC. General Specifications

Code Alert Series 30 Software User Guide

Alarm module for leak detection with webserver

ONYXWORKS AND FIRSTVISION. Version 4

E Programmble Smoke Detector Controller. Figure 1. Programmable Smoke Detector Kit

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

the Comprehensive Control Solution

Skyresponse ThingWorx Extension. Version 1.0. User Guide

Home center 2.7 Windows client Installation guide

Help. Help Software Tutorial. Building a Load Sizing Project with an NH-EL Humidifier and CSD Distributor.

Batt-Safe Battery String Monitoring System

wireless. web-based. worthy of the name RACO.

Connectivity Control Confidence

Product Brief for Alarm Analytics V9.3 October 2013

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS

DeltaV Operate. Product Data Sheet DeltaV Operate December 2006 Page 1. Introduction. Benefits

HikCentral Specification. HikCentral V1.1.1 Specification

Weekly Testing of Dedicated Stairwell Pressurization Fans- Metasys System Extended Architecture Code No. LIT

THE VALUE IS IN THE SOFTWARE

EnergyMaster. ENEC Monitoring System. An on-site supervision and remote monitoring solution

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

DATAssure. Laboratory wireless alarm & monitoring system

Dew point set DS 400

Making the Most of Alarms

Cold chain monitoring technologies. Facility monitoring

System 800xA Operations

Flexibility. adjusted to specific needs of a client.

Halton SAFE / 7.14 user guide and installation instructions

Complexity made simple

Transcription:

Samsung SDS BMS Ver.2.0 Technical Specification Technical Specifications All rights and title, including all intellectual property rights to Samsung SDS BMS" is retained by Samsung SDS Co, Ltd. ("SDS"), incorporated under the laws of Republic of Korea with a place of business at 123, Olympic-ro 35-gil, Songpa-gu, 138-861, Seoul, Korea ( SDS ). Main Features Samsung SDS BMS consists of four components, Base, Energy, Facility and Integration. It also provides the following features: BMS Base Category Function Description HVAC, Electricity and Lighting Control Real-time Monitoring Environment Control Flexible System Integration Programmable DDC Controller Built-in Energy Saving Logic System Monitoring Graphic Monitoring - HVAC, electricity and lighting control - Alarm notification and management - HVAC, electricity and lighting system integration - Industry standard open protocol support - Extensive list of protocol drivers - User-friendly logic programming tool (Logic builder/monitor) - Function Block Diagram (FBD) and User Defined Function Block (UDFB) - Scheduling, sunrise/sunset time-based dynamic scheduling - Enthalpy, duty cycle, night purge control - Demand control - Occupancy-based control - Real-time facility monitoring - Facility status display in tree map format - Alarm notification when a value goes outside of a user-defined range - Simple and intuitive views of facility - A variety of graphical elements such as images, texts, icons, and animated objects. - Animated icons to show facility status

Category Function Description Control Logic Monitoring - User-friendly block diagram based control logic and monitoring - 250 built-in function blocks - FBD(Function Block Diagram), User Defined Function Block (UDFB) Alarm Trends and Totalization Alarm Detection Alarm Notification and Acknowledgement Alarm History Data Collection and Real-time Trend Analysis Totalization - User configurable alarm range - Multiple types of event detection algorithm change of state, change of value, out of range - System and process alarm - Graphic page or control logic auto pop up when an alarm occurs - Priority based alarm management - Real-time alarm notification via SMS, e-mail, and push service - Alarm pop-up and sound alerts - Alarm acknowledged by operators - System and process alarm list - Alarm analysis and reporting - Alarm statistical summary - Facility operation data collection - Real-time data display - Visual representation of data in tables, charts - Multiple data comparison - Multiple types of totalization data support (accumulation, runtime, pulse, etc) - Visual representation of totalization data in tables, charts Historical Data - High-resolution historical data collection (one minute basis) - Visual representation of data in tables, charts

BMS Energy Category Function Description Real-time Energy Consumption Monitoring - Real-time energy usage data collection and visualization - Multiple types of data chart (bar, line, pie, donut, bubble, etc) Energy Consumption Energy Baseline Energy Consumption Forecast - Baseline model generation and savings tracking - Energy savings calculation - Visualization of energy savings performance - Energy consumption forecast through trend analysis - Energy consumption forecast through weather & energy consumption - Energy shortage and waste prevention Demand Forecast - Hourly electricity demand forecast - Electricity peak management Fault Detection and Diagnosis / Operational Guidelines Equipment Performance Evaluation Fault Detection and Operational Guidelines Improved Efficiency through Fault Diagnosis Alarm Notification Equipment Performance Evaluation Data Performance Diagnosis and Operation Improvement Report on Performance Data - Abnormal energy usage detection through equipment operation analysis - Equipment fault detection using fault detection and diagnosis engine - Guidelines to equipment faults - Equipment fault prediction - Operational guidelines to equipment faults - Potential risk detection to reduce maintenance costs - Alarm notification via SMS or e-mail - Fault history management - Anomaly detection through performance evaluation - Performance comparison of multiple equipment - Simple and intuitive evaluation chart - Performance indicators trend analysis - Early detection of performance degradation (e.g. using Coefficient of Performance) - Decision making support - A variety of visualization forms and templates - Easy to export data to Excel

Category Function Description Multi-site Dashboard - Building information display using GIS map - Event summary on individual buildings - Energy consumption comparison between buildings and between actual and benchmarks Energy Dashboard Single Building Dashboard - Monthly energy consumption data - Energy consumption display again the baseline - Building and equipment status information - Major event lists display Weather Data - Current weather condition display - 3 day weather forecast BMS Facility Category Function Description Equipment and Materials Equipment Materials - Standardized equipment list - Equipment data. Model name and image. Equipment components. Related documents. Operation history - Materials management support - Materials data. Materials information. Redundant materials. Materials shipping and receiving history Mobile Service Support - Quick access to equipment and material information using QR code

Category Function Description Standard Work Process - Standardized work category - Standardized work order process Work management Work Order management - Process-based work order (Type, Assignment, Individual work schedule Work history and statistics) - Work status management Mobile Service Support Meter - Work assignment and notification via SMS and push message service - Work result management (Time spent, issue, related images) - Meter categorization - Meter information and data management Operation result analysis Energy - Periodical energy consumption data collection - Operation history in chart or table form - Operation data analysis (Energy consumption pattern, Equipment operation pattern such as on/off, runtime) Work History and Statistics Floor Plan - Statistics on work history (Work history by group and individual, Group ranking based on total time spent on work, Material used and replaced, Equipment maintenance statistics chart) - Facility maintenance status - Floor plan management - Document upload and download - Document modification history management Floor plan,, Supplier and security area management Supplier - Supplier list - Supplier information - Contract information and contract status Security area (Patrol) - Patrol and security area management - Patrol support using mobile devices, QR code and RFID - On-site security status and patrol history management

BMS Integration Category Function Description Multi-system Integration - HVAC, electricity, lighting, CCTV, security, parking, network, audio/video, elevator, fire alarm systems integration - Single point of access to manage and monitor multi-system - Various control features System Integration System interlocking Multi-site management Open Standard and Proprietary Protocols Web-based User Interface Interlocking control Scenario-based Integration Priority-based Alarm Notification Event History Single Point of Access Single Point of User management Simple Integration and Easy Operation - Support for standard protocols BACnet, LonMark, Modbus, OPC, Web Services (XML/SOAP, REST), IEEE 802.15.4 wireless, etc. - Support for proprietary protocols to integrate non-standard equipment - Support for standard web browser - Remote access using mobile devices - Various user authentication mechanism (User ID and password, OTP) - Multi-system interlocking based on open standard protocols - Optimal control and automated process support - Scenario-based integrated control - Simple and intuitive logic diagram - Real-time monitoring of system integration (system, graphic, integration monitor) - Four level alarm priority(critical, high, medium, low) - SMS, Email, push service, pop-up and sound alerts - On/off line history - Interlocking event and history management - Inter-system event notification history management - Efficient monitoring and control for multiple buildings - Consistency for integrated monitoring - Building data sharing - Real-time emergency alerts - Decision making support and response to emergency - Role based user management (Administrator, engineer, operator, user, user group) - RBAC(Role-based access control) for multi-buildings - Flexible structure for building system integration (Easy to integrate new system, efficient interface using open standard protocols) - Simple and intuitive operation (Graphical user interface)

Requirement 1. System Requirements This part describes the system requirements for the computer used for BMS server. - OS: Microsoft Windows 7 (64-bit) with Microsoft IIS When installing more than two Components, Windows Server 2012 Standard (64-bit) is recommended. - Web Browser: Chrome latest version When installing BMS Base or BMS Integration, Chrome Version 43 is recommended. Samsung SDS BMS is based on HTML5, it is compatible with other browsers. But some functions may not work properly in other browsers. - Monitor resolution: 1920 x 1080 or higher resolution 2. Recommendations The screen resolution used by Samsung SDS BMS is 1920 x 1080. Graphs or charts may not work properly in low resolution mode. Please check the screen resolution. When installing BMS Base or BMS Integration, Chrome Version 43 is recommended. It is compatible with other browsers, but some functions may not work properly in other browsers. If you enter wrong password five times, the account will be locked temporarily. To use the account again, only an administrator can unlock the account. If you close the browser without clicking logoff and reconnect, you will probably encounter the message. You have logged from other browser or other PC. Do you want to disconnect the previous connection and reconnect? The encrypted files cannot be used for import function. The encrypted files should be decrypted before using import function.

Sales Items Sales Items of Samsung SDS BMS are following: BMS Base Sales Item Description Detail CC-BMS-3K CC-BMS-5K CC-BMS-10K CC-BMS-30K BMS Base Web version (~3,000 points) BMS Base Web version (3,001~5,000 points) BMS Base Web version (5,001~10,000 points) BMS Base Web version (10,001~30,000 points) - Apply 'Building Point' license policy - Points are determined by summing physical points (ex. AI, AO, BO, MSI, MSO, PI etc.) and interface points - Licenses are the same regardless of Main server or Standby server - Provides Configuration Tool(Install Package) and Mobile functions - In case of repurchase for renovation or remodeling of the Samsung SDS BMS applied building, the supply price is only 50% CC-BMS-P5K BMS Base Web version (+5,000 points) - When it gets over 30,000 points, additional costs is charged per 5,000 points CC-BMS-USER-EX BMS Base USER (Extended) - The default number of users by BMS Base site or building 1) Under 3,000 points: 3 Users 2) 3,001~5,000 points: 5 Users 3) 5,001~10,000 points: 10 Users 4) 10,001~30,000 points: 20 Users - In case of exceeding the default number, add 5 users each - The maximum number of concurrent user of BMS Base is 30 CCNX-S BMS Base C/S version (Server) - The number of server license is defined as the number of server which is physically setup. CCNX-C BMS Base C/S version (Client) - The number of client license is defined as the number of PC which is connected with BMS server physically.

BMS Energy Sales Item Description Description CC-BEMS-5K CC-BEMS-10K CC-BEMS-30K CC-BEMS-P5K BMS Energy Web version (~5,000 points) BMS Energy Web version (5,001~10,000 points) BMS Energy Web version (10,001~30,000 points) BMS Energy Web version (+5,000 points) - Apply 'Building Point' license policy - Points are determined by summing physical points (ex. AI, AO, BO, MSI, MSO, PI etc.) and interface points - Licenses are the same regardless of Main server or Standby server - Provides Configuration Tool(Install Package) and Mobile functions - In case of repurchase for renovation or remodeling of the Samsung SDS BMS applied building, the supply price is only 50% - When it gets over 30,000 points, additional costs is charged per 5,000 points CC-BEMS-USER-EX BMS Energy USER (Extended) - The default number of users by BMS Energy site or building 1) Under 5,000 points: 5 Users 2) 5,001~10,000 points: 10 Users 3) 10,001~30,000 points: 20 Users - In case of exceeding the default number, add 5 users each - The maximum number of concurrent user of BMS Energy is 30 BMS Facility Sales Item Description Description CC-BFMS BMS Facility Web version - Points which are related with other systems are given different licenses CC-BFMS-USER-EX BMS Facility USER (Extended) - Default number of BMS Facility users: 5 users by site (building) * Mobile App users included. If one person uses desktop and mobile at the same time, calculated as 2 users - In case of exceeding the default number, add 5 users each - The maximum number of concurrent user of BMS Facility is 50

BMS Integration Sales Item Description Description CC-IBMS-5K CC-IBMS-10K CC-IBMS-30K CC-IBMS-P5K CC-IBMS-VBD CC-IBMS-VBD-EX CC-IBMS-USER-EX BMS Integration Web version (~5,000 points) BMS Integration Web version (5,001~10,000 points) BMS Integration Web version (10,001~30,000 points) BMS Integration Web version (+5,000 points) BMS Integration VBD BMS Integration VBD (Stand alone, Extended) BMS Integration USER (Extended) - Apply 'Building Point' license policy - Points are determined by summing physical points (ex. AI, AO, BO, MSI, MSO, PI etc.) and interface points - Licenses are the same regardless of Main server or Standby server - Provides Configuration Tool(Install Package) and Mobile functions - In case of repurchase for renovation or remodeling of the Samsung SDS BMS applied building, the supply price is only 50% - When it gets over 30,000 points, additional costs is charged per 5,000 points - When the interface points get over 40,000, a physically separated VBD server has to be build - Range of interface points can be connected to a physically separated VBD: 40,001~50,000 - When the interface points get over 50,000 (BACnet + NonBACnet), build an additional separated VBD server until 30,000 points - The default number of users by BMS Integration site or building 1) Under 5,000 points: 5 Users 2) 5,001~10,000 points: 10 Users 3) 10,001~30,000 points: 20 Users - In case of exceeding the default number, add 5 users each - The maximum number of concurrent user of BMS Integration is 30 LEGAL DISCLAIMER Although SDS has attempted to provide accurate information on this document, SDS assumes no responsibility for the accuracy of the information. SDS may change the products or services mentioned at any time without notice. Mention of non- SDS products or services is for information purposes only and constitutes neither an endorsement nor a recommendation. Except where expressly provided otherwise, the site, including all content, materials, information, software, products and services therein, are provided on an as is and as available basis. SDS expressly disclaims all warranties of any kind, whether express or implied, including but not limited to, the implied warranties of merchantability, fitness for a particular purpose, non-infringement and warranties arising from a course of dealing, usage or trade practice. This documentation may contain typographical errors and technical inaccuracies.