Disaster Response Can Composites Prevent This? Construction, Corrosion, & Infrastructure Conference April

Similar documents
FR Veil Provides Low Cost Model to Achieve ASTM E-84 Class A Smoke Index

Nuclear Power Plant LSZH Cable Overview

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Fire Retardant Resins PERFORMANCE THAT TAKES THE HEAT

DualGuard Fluoropolymer Barrier FRP Duct. Composites USA. Fluoropolymer Barrier FRP Duct. A Critical Process Systems Group Company LISTED

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa

Market-Leading Non-Metallic Enclosure Brands

Generation, Assessment

Public Comment No. 1-NFPA [ Section No ]

Evaluation on Combustion Characteristics of Finishing Materials for Exterior Walls

Fire Test Methods ASTM NFPA UL ISO IEC

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Overview of fire retardants solutions PIN Flame Retardants in PVC cables

The Importance of Flame Retardant. Jackson Liu, 3M Taiwan

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process

CANADIAN FIRE ALARM ASSOCIATION An Update on Standards, Technologies and Solutions. Smoke Characterization Study

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

A Brief Introduction to Flame Retardants (FRs)

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

ASSESSING THE FIRE PERFORMANCE OF ELECTRIC CABLES (FIPEC)

We Identify and S.T.O.P. Your Noise Problems

Three fire retardant soft PVC with excellent environmental performance, ready for industrial use

Large-scale fire test for interior materials of the Korean high speed train

Review Fire Test Report

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

Understanding Etched Foil Flexible Heaters

ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC # TESTED: MARCH 27, 2009

Combustible Dust Hazard Recognition and Control NFPA Standards for Combustible Dusts

Benefiting Government, Industry and the Public Through Innovative Science and Technology. Barry L. Badders, Jr. P.E.

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

FUNDERMAX GMBH FIRE TEST REPORT

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

CLT Adhesive Tests in Support of Mass Timber Buildings

Report on Public Input June 2014 NFPA 101

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES

Copyright 2018 American Wood Council 1

Artificial Trees and Fire Performance

Protective & Marine Coatings Europe, Middle East, Africa & India

Loss Prevention Standards

Copy of article submitted to Fire Safety Engineering for publication January/February 2009

CEC CODE COMPLIANCE SEMINAR FOR ICC CHAPTER 8 INTERIOR FINISHES & DECORATIVE MATERIALS

Determination of Fire Exposure Heat Flux in Cable Fire Tests

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

NBS Smoke Density Chamber

Adrian Milford Sereca - a Jensen Hughes Company, Project Engineer Vancouver, BC, Canada

ASSESSMENT OF TIMBER PARTITION MATERIALS WITH FIRE RETARDANTS WITH A ROOM CALORIMETER

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

6/9/ :58 PM. First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

Fire propagation over combustible exterior facades exposed to intensified flame in Japan

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

Use of Flame Retardants to Comply with Fire Safety Requirements for Textiles. Marcelo M. Hirschler

Report Of Surface Burning Characteristics Tests On Fire Retardant Coating As Submitted By Contego International

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

IMO Resolution MSC 61(67): Annex 1: Part 2

Product Data Sheet Trespa HPL Panels

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

CAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL?

Fire Patterns. Introduction. Skills Objectives. Fire Effects and Fire Patterns (2 of 2) 12/20/ Knowledge Objectives

- CONSTRUCTION FIRE SAFETY STANDARDS

MEDIUM-DENSITY HOUSING # 7. Fire safety

Material Safety Data Sheet U.S. Department of Labor Occupational Safety and Health Administration

Saving lives with coatings

Acoustical Surfaces, Inc.

7.1 Smoke Detector Performance

A Look at General Cable s GenFree II Product Line

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

Fire Safety in a Laser Lab

PLASTICS WORKSHOP ENGINEERED. Learn About Thermoplastics Connect with Experts WESTBOROUGH / MASSACHUSETTS (BOSTON AREA)

Cablosam Tapes for Fire-Resistant Cables

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

Appendix: Standards and Specifications for Evaluation of Thermal Management in Electronic Industry

ASTM Fire Standards Table of Contents

CHOOSING CORE MATERIALS FOR AEROSPACE APPLICATIONS

Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

Heat and Smoke Release of a Ceiling-Installed Speaker

- CONSTRUCTION FIRE SAFETY STANDARDS

Franz Evegren. Robust brandriskbedömning ur ett IMO-perspektiv

UNDERSTANDING THE CHANGES TO CALIFORNIA TB ON FLAME RETARDANCE OF RESILIENT FILLING MATERIALS USED IN UPHOLSTERED FURNITURE

BS EN ISO : 2010

Report of Surface Burning Characteristics Tests on Samples As Submitted By Jotun UAE Ltd (LLC)

Reference to the Smoke Damage Index (SDI) is needed as it is part of the test method.

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

Test Report: ICL/H18/9039 Rev 1

FIRE TESTING OF LOW SLOPE ROOF ASSEMBLIES AN INTERNATIONAL REVIEW

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

MSA s Guide to Selecting the Right Flame Detector for Your Application

Contents: 4. Report of Surface Burning Characteristics Tests on LP FlameBlock/BlazeGuard (30-minute test) Updated April, 2010

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc.

EU flammability standards and ENFIRO

Safety Code Users. Fire Tests for Life SUPPLEMENT 3. Marcelo M. Hirschler FIRE PROPERTIES

FIRE TESTING OF ELECTRICAL CABLES FOR PUBLIC TRANSPORTATION

European Ethylene Producers Conference (EEPC) October 24-26, 2012 Flame Interaction and Rollover Solutions in Ethylene Cracking Furnaces

First Revision No. 6-NFPA [ Section No. 2.2 ]

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

Transcription:

February 2007 Qualify for a free subscription at www.cmmagazine.org Disaster Response Can Composites Prevent This? Construction, Corrosion, & Infrastructure Conference April 25-27 Construction, www.acmanet.org Corrosion, & Infrastructure Conference April 25-27 www.acmanet.org

FLAME RETARDANT Surface Mat Low Smoke Polyester Pultrusions at Low Cost By John Rowen Pultrusion is a continuous composite manufacturing process that is efficient and economical for the production of high-strength structural components that compete directly with steel and aluminum parts. For many markets, composite parts have two major advantages over steel and aluminum high strength-toweight ratio and corrosion resistance. For example, the U.S. Navy is accelerating the incorporation of composite materials into the fleet in order to both reduce weight and decrease maintenance. Lower weight translates to improved ship stability, speed, range, payload capability and fuel efficiency. However, one serious concern is the flammability of composite materials. Whether a fire is accidental or the result of hostile attack, those on board can t simply withdraw as if they were exiting a building. To address this concern, composite manufacturers have turned to bromine compounds as additives to their resins, with the result that flammability is reduced, but smoke production is increased. Other flame retardants are better at reducing 20 Composites Manufacturing www.cmmagazine.org February 2007

The Problem Defined Pultruded polyester (PE) components are widely used in a variety of building applications such as I-beams and C-channels, tubes and angles used for walkway and handrail systems, decking, ballistic panels, and cable trays. Pultrusions are often specified for applications requiring high strength and light weight, but in particular for use in corrosive environments. However, upon exposure to open flame or high radiant heat these materials can exhibit high surface flammability, smoke generation and toxicity (FST) characteristics. This is a particular problem when the end use is within a partially or entirely enclosed environment requiring egress. This fire hazard is subject to regulated life safety performance criteria set by local, state and Federal code governing authorities. Courtesy of General Atomics Fig. 1 The Electro-Magnetic Air Launch System (EMALS) design is a robust, highly reliable aircraft carrier launch system that will meet or exceed all Navy performance goals. smoke, but they are less efficient and must be added in such great quantity that the strength of the part is compromised. There is a novel method of fire hardening fiberglass composites using a fire-retardantcoated veil as the outer layer of a lamination schedule. Since only the surface is coated, the strength characteristics of the part remain the same, while fire is blocked from penetrating the interior of the part. Upon exposure to open flame or high radiant heat, the resultant manufactured product has surface flammability reduction comparable to a brominated resin manufacture, but with much less smoke and toxicity. For example, several Navy development programs that have benefited from the incorporation of this fire retarding (FR) and smoke-suppressing veil are the Electromagnetic Aircraft Launch System (EMALS)(Fig. 1) for aircraft carriers, the Light Weight Composite Stanchion (Fig. 2) for cargo ships, and the Very Light Weight Hatch (Fig. 3). Current Solutions: Bromine and ATH To address surface flammability, PE resins can be adjusted to have a significant degree of fire resistance (FR) by combining them with FR additives. Bromines, e.g., decabromodiphenyl ether oxide (DBDPE), are the most effective FR compounds in general use, especially when combined with the synergist antimony trioxide (ATO). However, under a fire load these brominated compounds produce large volumes of acrid particulate smoke and soot. Additionally, brominated FRs liberate decomposition byproducts such as hydrobromic acid (HBr) and other noxious species that can render the immediate environment biologically toxic, causing acute eye irritation and eventual asphyxia. Less toxic additives such as aluminum trihydrate (ATH) are preferable Official Magazine of the American Composites Manufacturers Association 21

Courtesy of General Dynamics / NASSCO Courtesy of KaZak Composites Fig. 2 Plunger actuated composite stanchion for the three hold types: Freeze/Chill (F/C), Specialty Cargo, and General Stowage. Figure 4. Intumescent Coating ASTM E-662 Standard Test Method for Specific Optical Density of Smoke Generated by a Solid Material OPTICAL DENSITY TEST RESULTS SUMMARY 22 Composites Manufacturing www.cmmagazine.org February 2007 NON-FLAMING FLAMING Ds 1.5 min. average: 0.6 3.9 Ds 4.0 min. average: 0.4 30.1 Dm(corr)(20.0 min.) average: 4.7 178.3 Figure 4 contains the results of an ASTM E-662 test on a non-fire retardantpe resin / balsa / glass sandwich panel that had an Avtec intumescent coating applied to it. Generally, if the non-flaming and flaming average values at 20 minutes are added together and have a result below 200, the specimen will likely have an ASTM E-84 Class A Smoke of <450. Figure 5. 50 kw/m2 Cone Calorimeter Test Results Comparing Three FR Mat Specimens to a Brominated Specimen Sample /Test # Placard Mass Correlated Correlated Duration of Peak Heat Initial Correlated Total Average Test (s) (kw/m 2 ) Mass(g) Conversion Smoke Smoke Release Factor Release(g) Production (g/m 2 /s) Sample 1 glass out 80.7 1.00 20.01.017 1198 91 (glass against die) Sample 2 FR out 81.6.99 18.58.019 1058 123 (FR against die) Sample 3 FR mat sandwich 82.2.98 14.95.011 1349 110 (two FR mats) Pultruded Bromine PanelPolyester Veil 40.6 1.99 52.26.140 465 185 Note: the Brominated panel at the bottom of the chart released a 261% greater quantity of smoke (correlated 52.26gm) compared to the FR Mat Sample 1 (20.01gm). Samples 2 and 3 illustrate contrasting results when the FR Mat is positioned in alternative orientations. Sample 2 had the FR side positioned as the surface i.e., glass rich side down. Sample 3 contained two FR Mats with the FR sides back to back forming a sandwich construction. Fig. 3 The Very Light Weight Hatch (30 x 60 ) can be operated by one individual as opposed to three for the steel hatch, thus eliminating the requirement for a secondary scuttle hatch. Tested to the UL 1709 protocol. from a toxicity standpoint, however the required high loading levels significantly degrade the desirable physical characteristics of the pultrusion. The Problem of Smoke Suppression: Acrylics and Phenolics Clearly, smoke suppressant additives for PE resins have not evolved to match the effectiveness and sophistication of the fire retarding additives. The difficulty of chemically suppressing smoke created by the combustion of a cured resin is exacerbated by the complex interaction between the resin and the flame retardant agent. The total complexity has stymied the development of any universal smoke suppressing additive options. Some success has been achieved with thermosetting modified acrylic and phenolic resins, however, these resins have their own set of issues. Such as very high hydrated mineral, e.g., ATH, loading for acrylic, and voids due to liquid vapor byproducts in phenolic. Compared to PE, composites comprised of these resins have a reputation of exhibiting brittle physical characteristics. What About Intumescent Coatings? Painting PE laminates with intumescent FR coatings can dramatically reduce the ability of a laminate to combust or generate smoke. Intumescents are a family of fire protective coatings containing constituents that react under high heat to form a protective charred layer. Once the under-laminate is shut off from the atmosphere by a sturdy, carbonific barrier, the combustion process is greatly

slowed. This layer both reduces surface ignitability, and reduces smoke by entrapment of the resultant smoke particles. Fig. 4 shows the results of an ASTM E-662 ( The Standard Test Method for Specific Optical Density of Smoke Generated by a Solid Material ) on a PE balsa cored sandwich panel coated with a fire-retardant paint. The results indicate low smoke production because the longer the exposure time, the more smoke and soot is packed into the coating, thus further shielding the laminate from ambient oxygen. This shielding results in a slow charring of the substrate rather than a more flammable, vigorous oxidation. However attractive from a life safety viewpoint, a secondary over coating on pultruded parts has numerous drawbacks. It can require code regulated paint application and drying areas. Spray application necessitates over-spray, often resulting in a loss of more than 30 percent of coating material. Coatings can be scored, scratched or chipped at any point during the coating s life cycle. For all of these reasons, the coating option has not received much acceptance. weighing each specimen during exposure to high radiant heat. In addition, the apparatus calculates smoke release over time, and measures peak heat. Each specimen was subjected to 50 kw/m 2 of radiant heat. The test run described in Fig. 5 compares four samples; three are various configurations of FR mat-protected vacuum-bagged samples, and one is a bromine-protected pultrusion. The FR mat has both a glass rich surface and an intumescent surface, so it was decided to test with 1) Glass side out, 2) Intumescent side out, and 3) Two veil layers with the intumescent sides touching. For reasons of pultrusion die wear, it is desirable to run with the glass side against the die, so the three tests were chosen to determine whether one would sacrifice fire performance by choosing that orientation. The mass of Sample 1, glass side out, was designated to be the baseline for mass correlation. As can be seen in Fig. 5, Sample 1 did indeed perform well, with a very low smoke and peak heat as compared to the brominated panel, and comparable to the other FR mat samples. Even though the vacuum bagged specimens had lower glass New Solution: Deliver Intumescents on a Surfacing Veil Using a veil or mat as a transport medium to deliver intumescent FR and smoke suppressing constituents to the surface of a pultrusion during a manufacturing process is a novel option. Surfacing veils, both glass and organic, have traditionally been employed to provide a resin-rich surface that enhances and maximizes the corrosion resistance and life cycle of a pultrusion. Augmenting that surfacing veil with FR agents on the underside provides an inter-laminate FR envelopment comparable to an intumescent secondary coating. Since the FR material is wet out by the PE resin, it becomes integral to the finished part, and cannot peel or chip. However, there remains the question of whether the PE resin on the surface will provide too much fuel to allow the finished part to pass a fire test. This and other issues were investigated by actual burn testing in the fire lab at Worcester Polytechnic Institute (WPI). Cone Testing the Performance of Intumescent-Coated Mats The Cone Calorimeter was used as the screening test apparatus because of its convenience and repeatability. Although the Cone instrument results don t predict specific E-84 results, better results on the Cone tests are highly correlated with better results on E-84 tests. ASTM E-1354 Cone Calorimetry enables fire safety engineers to measure the total quantity of particulate smoke released by Cut Costs & Turn Times for Lay-Up Tools Patented, CMPT lay-up mold technology for large, contoured composites slashes tooling, handling and energy costs. Custom made from any alloy at our four facilities. Drastically reduces mold-making time and costs. Ideal for complex-shaped reinforced composites. A General Magnaplate Division 1-800-441-6173 www.cmpttooling.com info@magnaplate.com Official Magazine of the American Composites Manufacturers Association 23

Figure 6a. Brominated Panel ASTM E-84-01 Smoke Developed Index Result Figure 6a contains the results of an ASTM E-84-01 test result preformed upon a commodity, PE pultruded flat sheet containing DBDPE. content than the brominated pultruded placard, e.g., 41 percent verses 52 percent, what the table clearly illustrates is a dramatic reduction in the propensity of the part to generate smoke for all FR mat specimens. Based upon these and many other Cone tests, the results were deemed sufficient to justify the fabrication of pultruded test panels and formally test them to the E-84-01 protocol. E-84 Comparison PE Pultrusions Protected by FR Mat Versus Bromine The FR mat test specimen was an assembly of four 1-foot by 12-foot pultruded panels butted together to form a 2-foot by 24-foot specimen. The bromine-protected specimen comprised two 12-foot pultrusions 2 feet wide, butted end-to-end. The tests were run at Southwest Research Institute. Figs. 6a and 6b show the E-84-01 results for those two specimens. While both specimens had nearly identical flame spread indices (FSI), the bromine-protected panel had a smoke developed index (SDI) more than 250 percent higher than the FR mat panel. In fact, the accompanying graph shows the brominated panel producing nearly total visual obscuration throughout the test. The FR panel actually under performed its potential, since at 3.5 minutes into the test the panel strips buckled slightly and the burner flame penetrated the center seam of the assembly, combusting the back of the panel which was not protected by the FR Mat. Smoke was observed entering the tunnel chamber through the center seam, originating from the unprotected, organic veiled surface. At 8 minutes the phenomenon and obscuration subsided. Despite the sizable penalty the panel seams created, the specimen easily passed the Class A smoke requirement. Initial concern about the burn-off of the PE resin on the 24 Composites Manufacturing www.cmmagazine.org February 2007

surface of the FR mat were confirmed by the early spike in the Fig. 6a graph, but that burning was only momentary. The net comparison of graphs in Fig. 6a and 6b clearly illustrates that the FR Mat dramatically reduces the capability of PE pultrusions to generate smoke when exposed to open flame. In summary, the fire and smoke testing presented in this article validate that a low cost, general purpose pultruded product can meet not only the flame spread requirement of E-84 Class 1, but additionally satisquare-feety the Class A low smoke requirement. This combined Class 1/A certification is a prescribed requirement by regulatory code governing authorities for enclosed environments requiring life safety egress. Additionally, the testing results suggest that new and promising opportunities in markets dominated by aluminum and steel, such as infrastructure, e.g., bridges, tunnels, electrical transmission, marine terminals; energy, e.g., mining, gas and oil; and, transportation, e.g., rail, truck, ships, are now open to low-smoke pultruded products. Subsequent application tests have verified that the FR mat will provide similar results when processed by filament winding, vacuum infusion and reinforced thermoplastic consolidation. For more details of these and other test results, you can log on to www.avtecind ustries.com. CM John B. Rowen is executive vice president & technical director at Avtec Industries in Hudson, Massachusetts. A graduate of the University of Massachusetts with a B.S. in Chemistry, Rowen worked for AKZO Nobel and Enduro Composite Systems. 978.562.2300; jrowen@avtecindustries.com. Figure 6b. Non-Brominated Panel ASTM E- 84-01 Smoke Developed Index with FR Mat Figure 6b contains the smoke obscuration result, SDI, of an ASTM E-84-01 derived from a low cost, PE pultruded flat sheet containing ATH as well as the resultant FR Mat. The % Light Obscuration at no time exceeds 50%. The FR Mat provided the necessary smoke suppression to achieve an SDI Class A rating. Official Magazine of the American Composites Manufacturers Association 25