DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

Similar documents
Unity DAU Voice Alarm System

16 Zone Voice Evacuation VA & PA Sound System

CFDAU30 Voice Alarm System

Distributed Amplifier Unit (DAU) (EESDAU100) Emergency Microphone All Call (EMA) (EESEMA) User Operational & Maintenance Manual

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Microphones VIGIL VIGIL. Unitouch. combined data sheets LEADING THE WAY TO SAFETY

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Voice Alarm. Multifunctional Voice Alarm Systems. certified to EN54

Intelligent Security & Fire Ltd

INTEGRITY VOICE ALARM ROUTING MATRIX

Experts in PA/VA Systems

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

INSTALLATION INSTRUCTIONS

Installation, Operating and Maintenance Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Bosch Plena Public Address and Voice Alarm System The fast route to safety

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

ANC BBX-FXMNS or BBX Audio Network Controller Board Installation Instructions TNC-5000 ANC Module Mounting Locations

Vocia VACIE. Reference Guide

Intelligent Security & Fire Ltd

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-5

OPERATION / INSTALLATION

Control Panel Engineering and Commissioning Instructions

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

VACIE REFERENCE GUIDE REVISION 1.2.6

VOICE ALARMING SYSTEM»ONE-BOX-DESIGN« EN / EN 54-4 / VDE / EN / VDE 0828 THE SIMPLE»ALL-IN-ONE«SOLUTION.

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

PTE0705 Electric Fence Monitor

Alarm Tone Generator Model AG17

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

sirens speakers and programmable controls

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

Instruction Manual SCD24. Read this document prior to installation. Contents

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Call stations and extensions

sirens speakers and programmable controls

DCS-100. intelligent damper control & monitoring system

Intelligent Line Module

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-9

AE300. Integrated Voice Alarm System

PREMIER EVACS 1-16 INSTRUCTION MANUAL: 2-ZONE NETWORKED VOICE ALARM PANEL INSTALLATION MANUAL

Application Guide YOGA STUDIO. Yoga Studio Zone. Page 1. JBL Commercial CS SERIES. Generic Copper Wire Mic/Line Cable

Fire Control Panel FS4000

Matrix Installation Manual. Software Version 4. EN Security Grade 2 Environmental Class 2 RINS918-1

REPEATER FS5200R INSTRUCTION MANUAL

Med Touch Master Alarm

Entero Voice Alarm system.

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Engineering Guideline. pac- Carriers Type Universal

C-Bus Four Channel General Input Unit Installation Instructions

Tri-Tech Medical Inc.

Fire Control Panel FS5100

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

Fire control panels FC726 FC726-XA

Intelligent Security & Fire Ltd

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

QA16 Addressable System

ECC-50/100C. Emergency Command Center

HRX Technical Manual. Version 1.2

Fire control panel detect 3004 plus and accessories

GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

FC722 Fire control panel

OmniCare EVC System. Installation & Commissioning Manual

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

Process & TeMPerATUre UniversAl input DigiTAl MeTers

ACCURATE ELECTRONICS INC

PUBLIC ADDRESS SYSTEM

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

User manual. KNXgal. version

EC-P Zone Intruder Alarm System

SMS GSM Alarm Messenger

TrueAlarm Fire Alarm Controls

USER MANUAL FOR OPERATING SYSTEM

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR

380 SERIES REMOTE SIREN ETSA380R

ME 3011C / Alarm Indication / Quick Reference Guide

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Flair 500 Series Annunciators

The Ultimate, Digital Public Address & Voice Alarm System FLEXIBILITY UNLIMITED

NU2 Smart Power Supply (SPS) Manual

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

OVEN INDUSTRIES, INC.

385 SERIES REMOTE HANDHELD SIREN ETSA385HR

DESCRIPTION INSTALLATION

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Break-in Detector and Alarm System

Maintenance Manual ALARM SHELF 19D902821P1 & P2. ericssonz LBI-38496C. TABLE OF CONTENTS (Vendor Documentation)

I-2000 INSTALLATION, OPERATION & COMMISSIONING MANUAL. 20/10/2009 Rev: 5.00

Building Technologies

Transcription:

DCA4 Digitally controlled Audio Matrix Product Specification March 2002 Current Thinking Document Number DDC DCA 7001 01 ACS

Introduction Voice Alarm (VA) systems are the quickest way to evacuate the public & staff from a building. Following fire detection, automated messages control the flow of people in stairwells and corridors allowing an orderly evacuation without panic. These messages are supplemented by spoken messages from the fire service or management suite confirming the validity and need to leave the building. This positive confirmation speeds evacuation and avoids the "false alarm" mentality reducing the risk of death from fire. Suitability Voice Alarm systems are recommended for all public buildings and multi story buildings over four floors by BS5588. In public buildings it's not possible to fire drill the public, as they visit the premises infrequently, so systems such as Voice alarms save valuable time in evacuating the building. The use of phased messages in multi-story buildings prevents overcrowding in stairwells and at exits, preventing secondary injuries. In phased evacuation, the floor in fire receives the evacuate message, and the floor above & below receive an alert message, preparing them for evacuation. In more complex scenarios the use of multiple alert and evacuate messages can be beneficial, messages telling the evacuees they are going the right way, and messages asking people to make way for people leaving evacuated areas. These additional messages can dramatically speed up the evacuation especially in malls and large airport environments. DCA4 Hardware Manual Page 2 2002 Current Thinking Ltd

Overview For small and medium sized installations this self-contained voice alarm controller provides an ideal solution. The basic controller has 4 monitored zone outputs, and the following inputs: 2 all call fire microphone ports, a data control port for networking & configuration, 2 four zone high priority microphone ports, 2 digital message slots (allowing four messages to be held in hardware), a six input fire alarm interface with common de-latch input (24V voltage inputs for connection to sounder circuits), 2 low priority zoned microphone ports, and three stereo music inputs. The front panel LCD allow selection of volumes, music sources and basic configuration as well as providing access to the 99-event fault log. In the event of processor failure the 2 fireman s inputs can access the whole system in line with EN60849. Standards Compliance The @udio Logistics DCA4 complies with all the current Voice Alarm standards including BS5839 parts 1,4 & 8 and EN60849. We are also monitoring the meetings of the EN54-16 committee to ensure we will comply when this is released. Additionally the DCA4 complies with the EMC requirements of EN55103-1 and EN55103-2. DCA4 Hardware Manual Page 3 2002 Current Thinking Ltd

System Inputs The DCA4 has a variety of inputs; these are fixed in priority and will be described in priority order. Fire Microphones Two fire microphone ports are provided, arbitrated on a first come first serve basis. The microphones are connected to the DCA4 via a standard RJ45 type 8 pin connector, which provides all power and control information to the microphone; all lines to the Fire microphones are monitored. Connections Din Rail Breakout (DRB s) boards are available to convert internal rack CAT5 type cables to 2.5mm 2 screw connectors for attaching to fireproof cables. The recommended cabling for the field microphones is 2 number 1.5mm 2 four core FP200 type soft skin cable for runs up-to 1KM, alternatively 2 number 4 core 1.5mm 2 MICC type cable can also be used, up-to a maximum distance of 200M Fire Microphone Connection Details 1 +24V nominal (18V to 32V) 2 Microphone Ground 3 PTT 4 Message trigger 1 5 Message trigger 2 6 Message trigger reset 7 Audio +Phase 8 Audio -Phase Signal Descriptions Power for the field microphone is provided by pins 1 & 2, which are protected by a PTC type self resetting fuse rated at 100mA. DCA4 Hardware Manual Page 4 2002 Current Thinking Ltd

Pins 3 through 6 normally rest at 2V, and are pulled to 5V by the field microphone to operate. Audio comes from the field microphone and is returned to the DCA4 via pins 7 & 8, this audio pair also indicates the operational status of the microphone by applying an 8V phantom voltage to the lines to indicate integrity of the microphone capsule and all field wiring. Operation The fire microphone has two functions, paging and message triggering. 1. Paging. Pressing the PTT button on the fire microphone raises the voltage on the PTT line to 5V, signalling to the control logic within the DCA4 that a microphone is required. The fire microphone input is on an ALL CALL basis and will override all four-system outputs. The routing and control of the paging audio from the fire microphone does not pass through any microprocessor, instead it is processed through state machine logic in line with EN60849 and is available in the event of any microprocessor failure. 2. Messages. Pressing one of the two message buttons on the fire microphone will raise the voltage on pins 4 or 5 to 5V signalling that a message is required, the default message triggers on the DCA4 are TEST and EVACUATE. Once triggered these messages repeat until the message RESET key is pressed. This informs the CPU in the DCA4 to stop the message at the end of the current cycle. DCA4 Hardware Manual Page 5 2002 Current Thinking Ltd

High Priority Microphones Two high priority microphone ports are provided, arbitrated on a first come first serve basis. The microphones are connected to the DCA4 via a standard RJ45 type 8 pin connector, which provides all power and control information to the microphone; all lines to the high priority microphones are monitored. Connections Din Rail Breakout (DRB s) boards are available to convert internal rack CAT5 type cables to 2.5mm 2 screw connectors for attaching to fireproof cables. If the microphones are required for secure (life safety) operation the recommended cabling for the field microphones is 2 number 1.5mm 2 four core FP200 type soft skin cable for runs up-to 1KM, alternatively 2 number 4 core 1.5mm 2 MICC type cable can also be used, up-to a maximum distance of 200M If the microphone is used for general paging (non life safety) operation, CAT5 FTP cable can be used up-to a maximum distance of 1KM. High Priority Microphone Connection Details 1 +24V nominal (18V to 32V) 2 Microphone Ground 3 PTT 1 4 PTT 2 5 PTT 3 6 PTT 4 7 Audio +Phase 8 Audio -Phase Signal Descriptions Power for the field microphone is provided by pins 1 & 2, which are protected by a PTC type self resetting fuse rated at 100mA. Pins 3 through 6 normally rest at 2V, and are pulled to 5V by the field microphone to operate. DCA4 Hardware Manual Page 6 2002 Current Thinking Ltd

Audio comes from the field microphone and is returned to the DCA4 via pins 7 & 8, this audio pair also indicates the operational status of the microphone by applying an 8V phantom voltage to the lines to indicate integrity of the microphone capsule and all field wiring. Operation By raising the PTT line of the relevant zone (s) (PTT 1 to 4) to 5V the microphone signals that paging to those zones is required. If neither of the fire microphones is in use the High Priority microphone will address the selected zone(s) overriding any lower priority inputs using those zones. DATA Page Port The data page port is designed to connect the DCA4 to intelligent paging panels or for networking multiple DCA4 s together to form a larger distributed system. Connection is via a standard RJ45 type 8 pin connector, which provides all power and control information to the microphone or network device; all lines on the data port are monitored. Data Page Connection Details 1 +24V nominal (18V to 32V) 2 Ground 3 RS422 TX+ 4 RS422 RX+ 5 RS422 RX- 6 RS422 TX- 7 Audio +Phase 8 Audio -Phase Signal Descriptions Pins 1 & 2, which are protected by a PTC type self-resetting fuse rated at 100mA, provide power for the microphones or network devices. Pins 3 through 6 form an asynchronous RS422 serial port. DCA4 Hardware Manual Page 7 2002 Current Thinking Ltd

Fire Alarm Interface The fire alarm interface provides automated delivery of pre-recorded messages stored within the DCA4. The DCA4 has two independent message generators, each of which has a high priority message and a low priority message; therefore allowing ALERT and EVACUATE messages to be broadcast simultaneously. Messages Following fire detection, the automated messages are required to give clear intelligible instructions. It is imperative that these message stores are of the highest quality and fully monitored. The @udio Logistics DCA4 uses the latest 16Mb Flash memories to store uncompressed 16 bit audio up to 65 seconds and up to CD quality within the matrix controllers. Messages are edited with standard PC based programmes such as Soundforge or Cooledit and uploaded to the message stores using our Windows application through the serial port of a PC. When the messages are not playing the on board processor continually checks the messages for integrity, and reports any deviation from the originally stored message as a fault. All our standard messages are studio recordings, these include; Alert, Evacuate, Test, Bomb, Coded Alert and Stand Down, however any custom message can be downloaded to the message store. Please contact us for details. Standard Messages The DCA4 comes with the following messages loaded as standard: @udio Safe High priority message Low Priority message module N o 1 EVACUATE TEST 2 ALERT STAND DOWN DCA4 Hardware Manual Page 8 2002 Current Thinking Ltd

Connections The Fire interface consists of 2 RJ45 type connectors which allows up to six external triggers to deliver messages. Din Rail Breakout (DRB s) boards are available to convert internal rack CAT5 type cables to 2.5mm 2 screw connectors for attaching to fireproof cables. The recommended cabling for the Fire Alarm connection is 4 number 1.5mm 2 four core FP200 type soft skin cable for runs up-to 500M, alternatively 4 number 4 core 1.5mm 2 MICC type cable can also be used, up-to a maximum distance of 200M Fire Interface 1 Connection Details 1 Message trigger 1 + 2 Message trigger 1-3 Message trigger 2 + 4 Message trigger 2-5 Message trigger 3 + 6 Message trigger 3-7 Message trigger 4 + 8 Message trigger 4 - Fire Interface 2 Connection Details 1 +24V nominal (18V to 32V) 2 Microphone Ground 3 Message trigger 5 + 4 Message trigger 5-5 Message trigger 6 + 6 Message trigger 6-7 Message RESET + 8 Message RESET - DCA4 Hardware Manual Page 9 2002 Current Thinking Ltd

Signal Descriptions All Message Trigger pairs are individually opto-isolated and designed for connection to reverse voltage monitored sounder circuits. Power is provided on pins 1 & 2 of interface connector 2 to allow messages to be triggered from closing contacts. Operation When 24V is applied to a Message Trigger pair the microprocessor in the DCA4 scans the cause and effects table and plays the messages defined into the relevant zones. The message triggers are latched and the messages continue to play until the message triggers are removed and the message reset pins have 24V applied. If the fire panel cannot provide a reset signal the inputs can be made momentary by permanently applying 24V to the MESSAGE RESET pins, in this case the message will play continuously while the message trigger voltage is present. A typical cause & effects table for phased evacuation is thus: Message Trigger Zone 1 Zone 2 Zone 3 Zone 4 1 EVAC ALERT 2 ALERT EVAC ALERT 3 ALERT EVAC ALERT 4 ALERT EVAC 5 TEST TEST TEST TEST 6 STAND DOWN STAND DOWN STAND DOWN STAND DOWN A typical cause & effects table for All Alert type evacuation is thus: Message Trigger Zone 1 Zone 2 Zone 3 Zone 4 1 EVAC ALERT ALERT ALERT 2 ALERT EVAC ALERT ALERT 3 ALERT ALERT EVAC ALERT 4 ALERT ALERT ALERT EVAC 5 TEST TEST TEST TEST 6 STAND DOWN STAND DOWN STAND DOWN STAND DOWN DCA4 Hardware Manual Page 10 2002 Current Thinking Ltd

Low Priority Microphones Two Low priority microphone ports are provided, arbitrated on a first come first serve basis. The microphones are connected to the DCA4 via a standard RJ45 type 8 pin connector, which provides all power and control information to the microphone; all lines to the low priority microphones are monitored. Connections Din Rail Breakout (DRB s) boards are available to convert internal rack CAT5 type cables to 2.5mm 2 screw connectors for attaching to fireproof cables. If the microphones are required for secure (life safety) operation the recommended cabling for the field microphones is 2 number 1.5mm 2 four core FP200 type soft skin cable for runs up-to 1KM, alternatively 2 number 4 core 1.5mm 2 MICC type cable can also be used, up-to a maximum distance of 200M If the microphone is used for general paging (non life safety) operation, CAT5 FTP cable can be used up-to a maximum distance of 1KM. Low Priority Microphone Connection Details 1 +24V nominal (18V to 32V) 2 Microphone Ground 3 PTT 1 4 PTT 2 5 PTT 3 6 PTT 4 7 Audio +Phase 8 Audio -Phase Signal Descriptions Pins 1 & 2, which are protected by a PTC type self-resetting fuse rated at 100mA, provide power for the microphones. Pins 3 through 6 normally rest at 2V, and are pulled to 5V by the field microphone to operate. DCA4 Hardware Manual Page 11 2002 Current Thinking Ltd

Audio comes from the field microphone and is returned to the DCA4 via pins 7 & 8, this audio pair also indicates the operational status of the microphone by applying an 8V phantom voltage to the lines to indicate integrity of the microphone capsule and all field wiring. Operation By raising the PTT line of the relevant zone (s) (PTT 1 to 4) to 5V the microphone signals that paging to those zones is required. If neither of the fire microphones is in use the High Priority microphone will address the selected zone(s) overriding any lower priority inputs using those zones. Music Inputs Three music inputs are provided, each of which is a stereo RCA type jack pair. The stereo inputs are combined to form mono sources which pass to a multiplexer which selects one of these audio sources to be available to the zones. The chosen audio source can then be routed to the zones from the front panel or using the remote music volume port. Music Volume Port 1 +24V nominal (18V to 32V) 2 Microphone Ground 3 Volume / Select 1 4 Volume / Select 2 5 Volume / Select 3 6 Volume / Select 4 7 NA 8 NA Signal Descriptions Pins 1 & 2, which are protected by a PTC type self-resetting fuse rated at 100mA, provide power for external devices. Pins 3 through 6 are internally pulled to 5V, if this pin is open circuit then music is NOT selected in the relevant zone, if shorted to ground music is selected at full level (set on the LCD) if remote volume is required then placing a variable resistor DCA4 Hardware Manual Page 12 2002 Current Thinking Ltd

between 0K and 10K will select the audio at a volume proportional to the position of the variable resistor with 0K being the loudest volume. Power Supply The DCA4 has 2 independent power supplies, fed through Klippon type 5mm connectors. The DCA4 expects between 18V and 32V from these connections and indicates their presence on front panel LEDs. Host Port The host port allows the DCA4 to be configured by a remote computer, using a standard AT type RS232 serial link. DCA4 Hardware Manual Page 13 2002 Current Thinking Ltd

Zone Outputs Four independently addressable zone outputs are provided by the DCA4. The zone outputs are connected to amplifiers or cascaded DCA4 s via a standard RJ45 type 8 pin connectors, which provides audio and control information to the amplifiers or cascaded mixers; all lines to the amplifiers are monitored. Connections Normally the DCA4 will be connected to the amplifiers or other routing equipment within a rack cabinet, and standard CAT5 patch leads can be used, however the audio feeds can be used to distribute amplifiers around the site and reduce heavy gauge speaker feeds for long cable runs, in this case the following cables can be used. Din Rail Breakout (DRB s) boards are available to convert internal rack CAT5 type cables to 2.5mm 2 screw connectors for attaching to fireproof cables. The recommended cabling for the field Amplifiers is 1 number 1.5mm 2 four core FP200 type soft skin cable for runs up-to 1KM, alternatively 1 number 4 core 1.5mm 2 MICC type cable can also be used, up-to a maximum distance of 200M Zone Output Connection Details 1 2 GND 3 PTT 1 4 NC 5 NC 6 NC 7 Audio +Phase 8 Audio -Phase DCA4 Hardware Manual Page 14 2002 Current Thinking Ltd

Signal Descriptions Pins 2 & 3, provide a two way handshake between the DCA4 and the amplifier or additional control equipment, the DCA4 monitors the voltage on the line, and normally expects to see 2V if the amplifier is healthy. Audio comes from the DCA4 via pins 7 & 8, this audio pair also indicates the operational status of the DCA4 by applying an 8V phantom voltage to the lines to indicate integrity of field wiring. Operation The DCA4 raises the line voltage to 5V to indicate the DCA4 wishes to use the audio output for priority paging. This sense voltage can be used to trigger external devices such as volume over ride relays or activating page only areas. If the DCA4 fails to see the 2V on the PTT line, and the output monitor option is set, the DCA4 signals a fault and places an entry into the front panel fault log. DCA4 Hardware Manual Page 15 2002 Current Thinking Ltd