Tamper & eather esistant Tamper esistant eather esistant Tamper & eather esistant eceptacles Proven safety solutions for compliance with 2011 National Electrical Code requirements
2011 NEC eceptacle equirements Code compliant protection from electrical injury The 2011 National Electrical Code has been updated to ensure proper receptacle safety in Dwelling Units, uest Suites, and Child Care facilities. 2011 NEC equirements for eceptacles 406.12 Tamper esistant eceptacles in Dwelling Units All non-locking type 15A and 20A, 125V receptacles in a dwelling unit (210.52) must be Listed as Tamper esistant, excluding the following locations: eceptacles located more than 5 ½ ft above the floor eceptacles that are part of a luminaire or appliance eceptacles located within dedicated space for an appliance that in normal use isn t easily moved Non-grounding receptacles used for replacements as permitted in 406.4(D)(2)(a) Each year, more than 2,400 children are injured by inserting foreign objects into receptacles. According to a 10-year study of National Electronic Injury Surveillance System (NEISS) data. 2 406.13 Tamper esistant eceptacles in uest ooms and uest Suites All non-locking type 15A and 20A, 125V receptacles in guest rooms and guest suites must be Listed as Tamper esistant. 406.14 Tamper esistant eceptacles in Child Care Facilities All non-locking type 15A and 20A, 125V receptacles in child care facilities (406.2) must be Listed as Tamper esistant. 406.9 eather esistant eceptacles All 125 and 250 volt, 15 and 20 ampere non-locking receptacles shall be Listed as weather resistant type in damp and wet locations. eather protective covers alone do not guarantee protection against potential exposure; in damp and wet locations weather resistant receptacles in weather protective covers must be used. Outdoor weather resistant receptacles must provide resistance to temperature extremes, excessive ultraviolet light and the effects of aging. UL Listed devices must have a marking clearly visible when installed. Tamper esistant T mold mark provides quick visual confirmation of tamper resistance when installed. Tamper & eather esistant Both the T mold mark and identifier are clearly visible in the finished installation, indicating double-layer protection for maximum safety. eather esistant identifier quickly indicates during inspections that a weather resistant device has been installed.
Tamper esistant eceptacles Tamper esistant receptacles feature a built-in UL Listed safety shutter system that prevents the insertion of foreign objects into the receptacle openings. The safety shutters will only open when a two-bladed plug presses simultaneously against the two shutters. Tamper esistant T eceptacle Internal Components: eceptacle openings are restricted by internal shutters (show above). Blocked Insertion: Insertion of object in any one side will not open shutters. Successful Insertion: Insertion of two-bladed plug at the same time will open shutters. eather esistant eceptacles eather esistant receptacles offer protection from rain, snow, ice, moisture, & humidity when properly eather esistant installed in an approved weather protective or while-in-use cover. The design of the eather esistant receptacles is distinctive because of the durable nylon housing and corrosion resistant metal components. Combine receptacles with any of our eatherboxtm hile-in-use Protective Covers for tough protection against the elements in any residential or commercial outdoor application. eather esistant eceptacles with corrosion resistant metal components eatherbox Cast Aluminum hile-in-use Protective Cover, Single-ang eatherbox Polycarbonate hile-in-use Protective Cover, Single or 2-ang Tamper & eather esistant eceptacles Tamper & eather esistant Tamper and eather esistant eceptacles provide both tamper resistant safety and ensure weather resistance in wet and damp outdoor locations. Areas that demand the use of Tamper & eather esistant eceptacles include: Homes & Apartments Assisted Living Facilities & etirement Communities Public Facilities & ecreational Areas 3
T eceptacles Project Name: Project Number: Catalog Number: Prepared By: Date: Type: T270 T1107 TC20 T6352 4.50" (114.3mm) 1.015" (25.8mm) 1.015" (25.8mm) 1.10" (27.9mm) 1.10" (27.9mm) Tamper esistant Tamper esistant eceptacles Single & Duplex eceptacles FEATUES Provides compliance with 2011 NEC Articles 406.12 406.14 for Tamper esistant eceptacles. T designation provides visual identification. Side-wire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire (T270, T1107, T780, & 9500T duplex devices only). 2-Pole, 3-ire 15A, 125V/AC 20A, 125V/AC Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper used (TC only). Durable impact-resistant thermoplastic face and back body is virtually unbreakable. esidential rade, Single and Duplex 15A 125V 5-15 Duplex eceptacle T270 A, B, BK, LA, V, Duplex eceptacle, Auto rounding T270-9 A, B, BK, LA, V, Decorator Duplex eceptacle T1107 A, B, BK, Y, LA, V, Decorator Duplex eceptacle, T1107-9 A, B, BK, Y, LA, V, Auto rounding Commercial rade, Single & Duplex F S * 15A 125V 5-15 Single eceptacle, Side ire T817 A, B, BK, Y, LA, V, Duplex eceptacle, Side ire TC15 A, B, BK, Y, LA, V, * Duplex eceptacle, Back & Side ire TB15 A, B, BK, Y, LA, V, Decorator Single eceptacle, Back T6250 A, B, BK, Y, LA, V, & Side ire * Decorator Duplex eceptacle, Back T6252 A, B, BK, Y, LA, V, & Side ire 20A 125V 5-20 Single eceptacle, Side ire T1877 A, B, BK, LA, V, Commercial Floor Box Duplex eceptacle, Side ire TC20 A, B, BK, Y, LA, V, * Duplex eceptacle, Back & Side ire TB20 A, B, BK, Y, LA, D,V, Decorator Single eceptacle, Back T6350 A, B, BK, Y, LA, V, & Side ire * Decorator Duplex eceptacle, Back T6352 A, B, BK, Y, LA, V, Side ire 5-15 5-20 15A 125V 5-15 Single Floor Box Assembly T5797 Black, Brass Assembly For ordering, include Cat. No. followed by the color code: A (Almond), B (Brown), BK (Black), Y (ray), LA (Light Almond), D (ed), V (Ivory), (hite) NAFTA Compliant C US 1.75" (44.5mm) T5797 2.75" (69.9mm) 3.50" (88.9mm) TESTIN & CODE COMPLIANCE culus Listed to UL498, UL943 file nos. E60120 (TVF, 9566, 9569), E15058 UL948 (all others), cul Certified to CSA C22.2, no. 42. TB, UL verified to Fed. Spec. C-596. NOM/ANSI Certified. T5797, culus File E92122, UL498 & UL514C cul to CSA C22.2 No. 18, CSA C22.2 No 42 MATEIAL CHAACTEISTICS Environmental: Flammability meets UL94 requirements; T817, T1877, T6250, T6252, T6350, T6352, TB, T270, T1107, TC V2 rated; T5797 V0 rated. Temperature ating: T270, T1107, TC: -20ºC to 60ºC (-4 F to 140 F); T817, T1877, T6250, T6252, T6350, T6352, TB: -20ºC to 70ºC (-4 F to 158 F); T5797: -40ºC to 65ºC (-40 F to 149 F) 4 www.cooperiringdevices.com
T eceptacles Project Name: Project Number: Catalog Number: Prepared By: Date: Type: Tamper esistant FEATUES Provides compliance with 2011 NEC Articles 406.12 406.14 for Tamper esistant eceptacles. T designation provides visual identification. Side-ire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire (T270, T1107, T780, & 9500T Duplex devices only). 15A 125V 5-15 Duplex eceptacle T8200 B, Y, D, V, Duplex FCI TVFH15 B, Y, LA, D, V, 20A 125V 5-20 Duplex eceptacle T8300 B, Y, D, V, Duplex FCI TVFH20 B, Y, LA, D, V, For ordering, include Cat. No. followed by the color code: A (Almond), B (Brown), BK (Black), Y (ray), LA (Light Almond), D (ed), V (Ivory), (hite) Hospital rade Tamper esistant eceptacles Single & Duplex eceptacles Construction rade Specification rade, Combination 2-Pole, 3-ire 15A, 125V/AC 20A, 125V/AC Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper used (Combination Devices only). Durable impact-resistant thermoplastic face and back body is virtually unbreakable. Combination LED Nightlight features dimmable nightlight that turns on in the dark and off in the light. (T7735) 15A 125V 5-15 Combination Single Pole Switch & T274 A, B, BK, LA, V, eceptacle Combination 3-ay Switch & T293 A, B, BK, LA, V, eceptacle Decorator Combination Single Pole T7730 A, BK, LA, V, & eceptacle Decorator Combination LED T7735 A, LA, V, Nightlight & eceptacle F S * 15A 125V 5-15 Duplex eceptacle T5262 B, Y, LA, V, 20A 125V 5-20 Duplex eceptacle T5362 B, Y, LA, V, 20A 125V 5-20 Combination Single Pole Switch & T291 A, B, BK, LA, V, eceptacle Specification rade, FCI 5-15 5-20 15A 125V 5-15 Duplex FCI TVF15 A, B, BK, Y, LA, D, V, 20A 125V 5-20 Duplex FCI TV20 A, B, BK, Y, LA, D, V, Hospital rade, eceptacles & FCI T274 T7730 T7735 T291 1.09" (27.7mm) 1.20" (30.5mm) 1.015" (25.8mm) 1.64" (41.7mm) TESTIN & CODE COMPLIANCE culus Listed to UL498, UL943 file nos. E60120 (TVF), E15058 (all others), except T8200 & T8300: Listed to UL498, file no. E15058. cul Certified to CSA C22.2, no. 42. TVF meets all UL943 and UL498 requirements. T5262, T5362, T8200/8300 UL verified to Fed. Spec. C-596. NOM/ANSI Certified. Combination devices, culus File E18704, UL20, UL498, cul File E18704, CSA 22.2 MATEIAL CHAACTEISTICS Environmental: Flammability meets UL94 requirements; T Combo Devices, TVF, T8200, T8300, 5262, 5362, V2 rated. Temperature ating: T Combo Devices: -20ºC to 60ºC (-4 F to 140 F); TVF: -35ºC to 66ºC (-31 F to 150.8 F); T8200, T8300: -40 C to 60 C (-40 F to 140 F); 5262, 5362: -20 C to 70 C (-4 F to 158 F). TVF15 1.64" (41.7mm) www.cooperiringdevices.com 5
& T eceptacles Project Name: Project Number: Catalog Number: Prepared By: Date: Type: B15 1.09" (27.7mm) eather esistant Tamper & eather esistant Duplex eceptacles eather esistant and Tamper & eather esistant eceptacles FEATUES Nickel-plated strap & mounting screws, and stainless steel terminal screws for corrosion resistance. Provides compliance with 2011 NEC Article 406.9 that states that all receptacles installed in wet and damp locations must be weather resistant. Manufactured with the highest grade of materials; durable impact-resistant thermoplastic face and back body is virtually unbreakable. 2-Pole, 3-ire 15A, 125V/AC 20A, 125V/AC 5-15 5-20 T and designations provide visual identification. Terminal screws are backed out and ready to wire. Patented built-in wire stripper for #14 and #12 wire to speed installation. Side-wire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire (T270 only). VF15 1.20" (30.5mm) Commercial rade, Duplex C US F S 426 15A 125V 5-15 Duplex eceptacle, Back & Side ire B15 B, Y, V, 20A 125V 5-20 Duplex eceptacle, Back & Side ire B20 B, Y, V, Specification rade FCI 15A 125V 5-15 Duplex FCI VF15 B, Y, V, 20A 125V 5-20 Duplex FCI V20 B, Y, V, C US 426 T270 1.015" (25.8mm) T esidential rade, Duplex 15A 125V 5-15 Duplex eceptacle T270 LA, V, T Commercial rade, Duplex C US F S 426 15A 125V 5-15 Duplex eceptacle, Back & Side ire TB15 B, Y, V, 20A 125V 5-20 Duplex eceptacle, Back & Side ire TB20 B, Y, V, TVF20 1.64" (41.7mm) T Specification rade, FCI 15A 125V 5-15 Duplex FCI TVF15 B, Y, LA, V, 20A 125V 5-20 Duplex FCI TV20 B, Y, LA, V, For ordering, include Cat. No. followed by the color code: B (Brown), Y (ray), LA (Light Almond), V (Ivory), (hite) TESTIN & CODE COMPLIANCE culus Listed to UL498. cul Certified to CSA C22.2, no. 42. VF & TVF meet all UL943 (FCI) and UL498 (eceptacles) requirements. B and TB UL verified to Fed. Spec. C-596. NOM/ANSI Certified. MATEIAL CHAACTEISTICS Environmental: Flammability meets UL94 requirements; T270 V2 rated; VF, B, TB, TVF V2 rated. Temperature ating: T270: -20ºC to 60ºC (-4 F to 140 F); VF, TVF: -35ºC to 66ºC (-31 F to 151 F); B, TB: -20ºC to 70ºC (-4 F to 158 F). 6 www.cooperiringdevices.com
T eceptacles Project Name: Project Number: Catalog Number: Prepared By: Date: Type: Tamper esistant Tamper esistant eceptacles FEATUES Designed to coordinate with the unique look of the ASPIE Design System - Available in three distinctive, two-tone color combinations hite Satin, Desert Sand and Silver ranite. Features our correct wiring/trip indicator light technology, making certain that every installation is properly wired to provide optimal protection. Indicator light provides quick visual reference of a tripped or end of life condition. eset button lock-out function protects from miswired line-load connections and FCI circuitry damage. 2-Pole, 3-ire 15A, 125V/AC 20A, 125V/AC ASPIE Collection & ecessed eceptacles 5-15 5-20 Trip threshold (5ma+/-1ma) and response time (0.025 sec.) meet Class A requirements. Ultrasonically welded backbody. 20 amp feed-through rating allows full protection of downstream receptacles when wired from load side. round screw backwiring clamp for fast, secure termination. Maximum wiring flexibility is provided with 8 separate backwiring holes that accept up to #10 A stranded or solid wire. Longer, wider bridged strap provides 40% more contact area with wallboard, virtually eliminating floating installations. ASPIE eceptacles & FCI 9566T (106.43mm) (33.0mm) (33.0mm) 1.20" (30.5mm) 3.81" (96.8mm) 3.81" (96.8mm) 15A 125V 5-15 ASPIE Duplex eceptacle 9505T A, DS, S, S ASPIE Single eceptacle 9507T A, DS, S, S ASPIE Duplex FCI 9566T A, DS, S, S 20A 125V 5-20 ASPIE Duplex eceptacle 9510T A, DS, S, S ASPIE Single eceptacle 9508T A, DS, S, S ASPIE Duplex FCI 9569T A, DS, S, S (83.31mm) 9508T.85" (21.59mm) esidential rade, ecessed 15A 125V 5-15 ecessed Single eceptacle T775 ecessed Duplex eceptacle T780 For ordering, include Cat. No. followed by the color code: A (Alpine hite), DS (Desert Sand), S (Silver ranite), (hite), S (hite Satin) NAFTA Compliant TESTIN & CODE COMPLIANCE culus Listed to UL498, file nos. E60120 (9569T), E15058 (all others): Listed to UL498, file no. E15058. cul Certified to CSA C22.2, no. 42. NOM/ANSI Certified. elated Products MATEIAL CHAACTEISTICS Environmental: Flammability meets UL94 requirements; 9566T, 9569T, 9505T, 9507T, 9508T, 9510T, T775, T780, V2 rated; Temperature ating: 9510T: -20ºC to 60ºC (-4 F to 140 F); 9505T, 9507T, 9508T: -20ºC to 70ºC (-4 F to 158 F); T775, T780: -20ºC to 70ºC (-4 F to 158 F); 9566T, 9569T: -35ºC to 66ºC (-31 F to 150.8 F). 4.48" (113.8mm) T780 2.72" (69.1mm) 0.93" (23.6mm) 2" (50.8mm) For more information about Cooper iring Device's eatherproof covers and boxes, use the Q code above or visit: http://bit.ly/wthrcvr For more information about Cooper iring Device's complete ASPIE Collection, use the Q code above or visit: http://bit.ly/aspiresystem www.cooperiringdevices.com 7
Download a 2D barcode reader application to your smart phone to visit us online: www.cooperiringdevices.com Cooper iring Devices United States 203 Cooper Circle Peachtree City, A 30269 P: 866-853-4293 F: 800-329-3055 Canada 5925 McLaughlin oad Mississauga, Ontario, L5 1B8 P: 800-267-1042 F: 800-761-5748 www.cooperwiringdevices.com email: custserv@cooperwiringdevices.com cwdmarketing@cooperindustries.com Cooper iring Devices, Aspire and eatherbox are valuable trademarks of Cooper Industries in the U.S. and other countries. You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries. 2011 Cooper Industries, plc. Mexico Carr. Tlalnepantla Cuautitlan Km 17.8 s/n Col. Villa Jardin esq. Cerrada 8 de Mayo Cuautitlan, Mexico CP 54800 P: +525558999190 F: +525526207116 www.cooperwiringdevices.com.mx Your Authorized Cooper iring Devices Distributor is: Cooper Industries, plc. 600 Travis, Ste. 5600 Houston, TX 77002-1001 P: 713-209-8400 www.cooperindustries.com 9-TTBOC-11