Burner Company. Flame Safeguard Systems. Bulletin IG-1. Bulletin FS-1

Similar documents
Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.

Flame relay units are necessary in most industrial combustion systems. These flame relay models are capable of meeting most application needs.

ED510 DISPLAY MODULE. FOR USE WITH FIREYE FLAME-MONITOR AND MicroM BURNER MANAGEMENT CONTROLS DESCRIPTION INSTALLATION APPROVED

STEAMPAK Series BurnerPAK BMS Burner Management Systems

Distributed By: M&M Control Service, INC

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

FIREYE C9707A ALL FUEL SCANNER

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

FIREYE E210/211 FLAME-MONITOR

BURNER MANAGEMENT CONTROLS

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

FIREYE FLAME SCANNERS

Fireye FLAME SCANNERS

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

E110 FIREYE FLAME-MONITOR BURNER MANAGEMENT CONTROL FOR USE WITH THE MICROPROCESSOR-BASED EP AND EPD STYLE PROGRAMMER MODULES

SEC 2000 Millenium Infrared Gas Detector

Transfer Switch Features

7800 SERIES EC7823/RM7823 Relay Module

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Transfer Switch Features

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

Variable Frequency Drive SERIES MP800 VFD

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Commercial and Light Industrial Fire Alarm Control Panel

X11CA COMPUTER ANNUNCIATORS

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Burner Management and Combustion Control. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.

Soft Start Series MP700 Solid State, Reduced Voltage

E340 BOILER CONTROL INSTALLATION MANUAL

7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules

Across-the-Line SERIES MP300 Combined Manual and Automatic

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

FIREYE FLAME SCANNERS

RTD TEMPERATURE SENSING SYSTEM

7800 SERIES RM7840E,G,L,M Relay Module

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

AIS750 Series Alarm Annunciator

LMR Electric Fire Pump Controllers Features

configurable safety and programmable logic SLATE Integrated Combustion Equipment Management The revolutionary integration of

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

7800 SERIES RM7888A Relay Module

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

Honeywell SLATE ICM Platform

7800 SERIES RM7888A Relay Module

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

LMR Electric Fire Pump Controllers Features

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

FIREYE FLAME SCANNERS

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Tri-Tech Medical Inc.

Med Touch Master Alarm

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

FIREYE FLAME SCANNERS

7800 SERIES EC7885A/RM7885A Relay Module

FIREYE YZ300 and YZ320 INTERLOCK ANNUNCIATOR For use with the Fireye BurnerLogix Control

TECHNICAL DATA OBSOLETE

Indirect gas-fired air heater

SECTION LIGHTING CONTROLS

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

RACO's Verbatim Gateway keeps you in touch, and in control, no matter where you are.

Model A1700 Series Annunciator

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

PRODUCT: SEL-SV-MCQ-O5- K6 VERSION TECHNICAL SHEET 1/5 SAC

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

COMBUSTION CATALOG. Honeywell Thermal Solutions Honeywell Thermal Solutions Combustion Catalog

Honeywell Thermal Solutions COMBUSTION CATALOG

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

FIREYE EPD260, EPD261, EPD270 PROGRAMMER MODULES

FLAME SAFEGUARD FOR BURNER MANAGEMENT SYSTEMS

FT60 Reduced Voltage - Autotransformer

Eclipse 90 UV Scanner Model A Version 1

Complete Boiler Management in a Compact, Affordable System

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Safety & Installation Instructions

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

DIESEL Engine Fire Pump Controllers Features

FDF Foam Pump Controllers Features

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

Section PERIMETER SECURITY SYSTEMS

MBCE-110/230UV Flame Sensor Module

Power Flame Incorporated

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

The key element for your process

Symbols for Control Panels

ISIS USERS MANUAL I.S.I.S. 550B

Transcription:

Burner Company Flame Safeguard Systems Bulletin IG-1 Bulletin FS-1

Flame Safeguard Systems Flame Safeguard Model Identification (Example of a typical spec): FSG - E110/E300 - UV - NFPA/IRI/FM - W3 - FC - S 1 2 3 4 5 6 1 2 3 4 5 6 Notes: Sequencer type Enter one of the following: E110 = Fireye E110 Flame Monitor E110 / E300 = Fireye E110 Flame Monitor with Fireye E300 Expansion Module SLC1= Allen-Bradley SLC500/01 programmable controller &14 point annunciator SLC4 = Allen-Bradley SLC500/04 programmable controller & 14 point annunciator SLC5 = Allen-Bradley SLC500/05 programmable controller & 14 point annunciator Flame Scanner Type Enter one of the following: UV = Self checking ultraviolet (uv) scanner & UV Flame Amplifier IR = Infrared (ir) Scanner & IR Flame Amplifier Insurance Requirements Enter one of the following: NFPA/IRI = National Fire Protection Association and Industrial Risk Insurers NFPA/IRI/FM = National Fire Protection Association, Industrial Risk Insurers, and Factory Mutual Water Level Relays Enter one of the following: W0 = None W1= Low Water Cutout Relay W2 = W1 plus, Low Water Level Alarm, High Water Level Alarm, and Alarm Bell (Alarm bell rings until the water level is restored to the proper level.) W3 = W2 plus, Water Level Alarm Bell Silence Push Button, and Water Level Abnormal Light (The push button silences the alarm bell, the light remains on until the water level is restored to the proper level.) Options Enter as many as required, separate entries by back slashes: FC = Fuel change at low fire without shutting the unit down N4 = NEMA 4 enclosure in lieu of the standard NEMA 12 enclosure RP = Free standing remote panel in lieu of the standard burner mounted panel SF = Simultaneous firing of two fuels, an Allen-Bradley SLC 500 series processor is required for this option. Enter (S) if any special requirements and note requirement For example: Customer requires the following dry contacts for remote annunciation, Burner On, Burner Flame Failure, High Water Level Alarm, and Low Water Level Alarm. If the available flame safeguard power supply is other than 120 vac/3 phase/60 hertz, enter (s) in the position 6 on the flame safeguard model number, and note the available flame safeguard power supply on the burner specification sheet. *Allen-Bradley processors are a product of Rockwell Automation Inc. 14

FABER Flame Safeguard Systems 15 Model: FSG-E110/E300-UV-NFPA/IRI-W3 Model: FSG-SLC4-UV-NFPA/IRI-W3 Right Hand (RH) unit shown. Left Hand (LH) unit is a mirror image of RH unit.

Model: FSG-E110/E300-UV-NFPA/IRI-W3 Flame Safeguard Model: FSG-SLC4-UV-NFPA/IRI-W3 Flame Safeguard 16 1 Fireye ED 510 Display module 2 Push buttons, lights & switches 3 Alarm horn & Bell 4 14 point First Out Annunciator 5 Burner voltmeter 6 Push buttons, lights & switches 7 Alarm horn & Bell

SEQUENCER TYPES E110 - The Fireye E110 Flame Monitor is a microprocessor based burner management control system with self-diagnostics and non-volatile memory. The Flame Monitor provides the proper burner sequencing and displays the burner status on the ED510 display mounted on the flame safeguard panel enclosure. The Flame Monitor has a fixed or burnt in memory and cannot be field adjusted or customized. Customization requires the addition of external timers and relays. E110/E300 - Adding a Fireye E300 Expansion Module to the Fireye E110 Flame Monitor upgrades the display module to a first out annunciator. Lockout alarm messages are displayed on the ED510 display mounted on the flame safeguard panel enclosure. This feature is very helpful when trouble shooting the system. For instance, if the burner trips due to low gas pressure, the message 3 P Low Gas Pressure will scroll across the display module. Without the E300 expansion module, any trip due to a safety limits failure is displayed as 3 P INTLK OPEN. SLC1, SLC4, and SLC5 Summary The Allen-Bradley SLC 500 series processors are rugged and dependable programmable controllers, designed to withstand harsh industrial environments. Because these processors are both modular in design and have several communication options available, they can be easily factory configured to meet specific project requirements. Each unit is factory programmed and tested. The program is backed up on an EEPROM or Flash Memory module located on the processor. A 14 point first out annunciator is a standard offering with all Allen-Bradley SLC 500 series processors. The annunciator has integral Test, Acknowledge, and Reset push buttons. All the burner safety limits are annunciated by 1 7/16 h x 3 5/16 w lighted windows. SLC1 = Allen-Bradley SLC 5/01 processor, with EEPROM memory module, all the necessary digital input and output cards, and a DH-485 communication port. SLC4 = Allen-Bradley SLC 5/04 processor, with Flash Memory module, all the necessary digital input and output cards, a DH+ communication port, and an RS-232 port which can be configured to communicate with a DH-485 network. SLC5 = Allen-Bradley SLC 5/05 processor, with Flash Memory module, all the necessary digital input and output cards, an Ethernet communication port, and an RS-232 port which can be configured to communicate with a DH-485 network. 17

FLAME SCANNER TYPES UV, IR Summary All flames emit electromagnetic waves: ultraviolet (UV) radiation, visible radiation, and infrared (IR) radiation. Typically, the flame spectrum generated by an oil or gas flame is approximately 1% UV radiation, 10% visible radiation, and 89% IR radiation. UV radiation usually originates from the first third of the flame, or the flame base. IR radiation originates largely from the last two thirds of the flame. IR radiation is also emitted from surfaces with a temperature greater than 1000ºF, such as hot refractory. Either type of flame scanner, UV or IR, can detect the presence or absence of an oil or gas flame. However, IR type flame scanners should never be used in an application where the scanner can see hot refractory in a furnace. UV Fireye self-checking UV flame scanner and UV flame amplifier. IR Fireye IR flame scanner and IR flame amplifier. INSURANCE REQUIREMENTS NFPA/IRI The system will be designed per the National Fire Protection Association Standard for Single Burner Boiler Operation (NFPA 8501), and Industrial Risk Insurers standard for Single Burner Boiler-Furnaces (IRInformation section IM.4.1.1). NFPA/IRI/FM The system will be designed per the National Fire Protection Association Standard for Single Burner Boiler Operation (NFPA 8501), Industrial Risk Insurers standard for Single Burner Boiler-Furnaces (IRInformation section IM.4.1.1), and Factory Mutual Engineering Corporation standard for Oil and Gas Fired Single Burner Boilers Property Loss Prevention Data Sheet (Factory Mutual 6-4 12-69). WATER LEVEL RELAYS WO = None W1 = One Warrick electromechanical low water cutout relay, wired into the safety limit circuit. W2 = W1 plus, Low Water Level Alarm, High Water Level Alarm, and Alarm Bell (Alarm bell rings until the water level is restored to the proper level). W3 = W2 plus, Water Level Alarm Bell Silence Push Button, and Water Level Abnormal Light (The push button silences the alarm bell, the light remains on until the water level is restored to the proper level). OPTIONS FC = Fuel change at low fire without shutting the unit down. With this equipment, a fuel change is performed as follows: The fuel change switch is turned to the on position. The unit moves to the low fire position. At low fire, the ignitor is energized. The fuel selector switch is turned from the current fuel, to the other fuel. The fuel change switch is turned off. N4 = NEMA 4 flame safeguard panel enclosure in lieu of the standard NEMA 12 enclosure. RP = Free Standing panel in lieu of the standard burner mounted panel. SF = Simultaneous firing of two fuels, an Allen-Bradley SLC 500 series processor is required for this option. 18

Your Local FABER Representative: FABER BURNER COMPANY 857 Maple Street Lock Haven, PA 17745 888-FABER11 E-Mail: sales@faberburnercompany.com 570-748-4009 (888-322-3711) WEB: http://www.faberburner.com Fax 570-748-4324