User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

Similar documents
Combi Eco Elite Range. User s Guide and Important Warranty Information

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

User Guide. Promax SL Condensing Central Heating Boiler

Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier.

User Guide. Duo-tec Combi LPG. Gas Fired Wall Mounted Condensing Combination Boiler

User Guide. Main Eco Elite Combi Condensing Central Heating Boiler

User Guide. Platinum Combi Gas Fired Wall Mounted Condensing Combination Boiler

User Guide. Gold Combi Condensing Combination Boiler

User s Operation Instructions & Important Warranty Information

User Guide and Important Warranty Information Condensing Central Heating Boiler

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h

Avanta 12v - 15v - 18v - 24v - 30v

Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s

User Guide Combi. Condensing Combination Boiler

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

User Guide. Promax Store 24. Condensing Boiler with Integrated Hot Water Storage

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

User Guide. EcoBlue Advance Heat Gas Fired Wall Mounted Condensing Boiler

Baxi Maxflow Combi WM

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Baxi Maxflow Combi FS

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Osprey 2 CFL

User Guide. Assure Heat Condensing Central Heating Boiler

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

MERIDIAN HE 30 C. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

MURELLE EV HE 25/55-30/55

ir-range 8G /03.15 Changes reserved.

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

User Guide. EcoBlue System Gas Fired Wall Mounted Condensing System Boiler

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Baxi Bermuda Inset 3 Super

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Baxi Brazilia F 5, F 5S, F 8S & Comfort Stat F 8ST Oak

Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

24CDi, 28CDi & 35CDi II COMBI

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

GREENSTAR HIGHFLOW 440/550CDi

INSTALLER AND OWNER GUIDE

User's Instructions. Alpha CB50

Greenstar 12i/24i System

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Model 347 BLACK BEAUTY

INSTALLER AND OWNER GUIDE

Open Vented Condensing Boilers

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

Multifit. Installation & Commissioning Instructions

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

Vote for your Installer of the year at HEATSLAVE

GREENSTAR HIGHFLOW 440/550CDi

Fitting & Commissioning Instructions. EcoBlue Combi and System Range. Outdoor Sensor Kit. Kit Part No (System) Kit Part No.

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Model 341 Black Beauty Slimline

12.0 Servicing. Electrode Position Fig Annual Servicing Inspection (Cont) 4 ±0.5

24/30/38. E-Combi. CONDENSING WALL HUNG COMBINATION BOILER G.C.N : (24 kw) G.C.N : (30 kw) G.C.N : (38 kw)

USERS GUIDE 24, 30. For installation guide see reverse of book

GB24 & GB30. User Manual

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

Installation & User s Instructions

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Model 809 Electric Heater

Model 741FS. Dream, Heritage or Opulent OWNER GUIDE. INSTALLER: Please leave this guide with the owner Baxi Heating U.K. Limited 2007.

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Greenstar 12i system / 24i system

USER GUIDE LOGIC HEAT H

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

AquaNova. Water heater. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

iheat 25c iheat 30c iheat 35c

USER GUIDE VOGUE MAX SYSTEM

Ecogen 24/1.0. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler and Power Generator

Contacts: Potterton. For latest prices and delivery to your door visit MyTub Ltd

Logic+ Combi

GREENSTAR CAMRAY EXTERNAL & EXTERNAL SYSTEM12/18, 18/25, 25/32

Statesman. Users Instructions. 45/50, 50/70, 70/90, 90/110, System, Flowsure, Flowsure +, Utility 50/70, 70/90, 90/110, 110/130, 130/150

USERS GUIDE. LOGIC+ Combi 24, 30, 35

GREENSTAR HEATSLAVE II EXTERNAL 12/18, 18/25 & 25/32

E-COMBI EVO E-SYSTEM EVO

condens Instructions for Use Ultracom 2 35 Store G.C. No

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

Model 956 OWNER GUIDE. This guide to be left with the owner INSET LIVE FUEL EFFECT GAS FIRE

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Baxi Bermuda Inset 3 Super

Operating instructions

GREENSTAR CAMRAY UTILITY & UTILITY SYSTEM

Transcription:

You can rely on User Guide and Important Warranty Information Promax System HE Plus A Range Condensing System Boiler Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Baxi Heating UK Ltd 0

Contents Natural Gas Potterton Promax System HE Plus A G.C.N o 59 99 Potterton Promax System 5 HE Plus A G.C.N o 59 0 Potterton Promax System 8 HE Plus A G.C.N o 59 0 Potterton Promax System HE Plus A G.C.N o 59 0 Potterton Promax System HE Plus A G.C.N o 59 0 Section Page.0 Quick Reference Guide.0 Troubleshooting.0 Repressurising System 6.0 Clearances 7 5.0 Care of the Boiler 8 6.0 Legislation 9 7.0 Notes 0 8.0 Emergency 9.0 Warranty & Service The Benchmark Scheme Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance. Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk Baxi Heating UK Ltd 0 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature (including in any database), in each case whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner, except for permitted fair dealing under Copyrights, Designs and Patents Act 988. Applications for the copyright owner s permission to reproduce or make other use of any part of this publication should be made, giving details of the proposed use, to the following address: The Company Secretary, Baxi Heating UK Ltd, Brooks House, Coventry Road, Warwick. CV LL Full acknowledgement of author and source must be given. Boiler Controls - see opposite page for Operating Quick Reference Guide WARNING: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages. 0086 ISO 900 FM 00866 Baxi Heating UK Ltd 0

.0 Quick Reference Guide 0 ON/OFF/ Selector Switch Display Central Heating Temperature Control Calibration Control System Pressure Gauge OFF Position The boiler will not operate. Central Heating & Hot Water Both Heating & Hot Water will operate. Hold for approx 5 seconds and release. Central Heating Indicator - The indicator will illuminate when the boiler is in the central heating mode. Burner On Indicator - The indicator will illuminate when the burner has fired and is heating your central heating or domestic hot water. Display Boiler Output Temperature - In either the central heating or domestic hot water position the display will illuminate showing the current boiler temperature in degrees centigrade. Central Heating Temperature Control Turn the knob clockwise to increase or anticlockwise to decrease the temperature. Range 5-80 C. Calibration Control This control is for use only by the installer or service engineer. 0 Central Heating System Pressure - The normal operating water pressure is between and.0. If the pressure exceeds the safety pressure valve will operate and a fault is indicated. Contact your Installer. Baxi Heating UK Ltd 0

Boiler not working START.0 Troubleshooting Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g. fire, cooker). Is the ON/OFF/ Select Switch in the ( ) position and the display lit? Central Heating Indicator Is the ( ( ) on? ) light on and the If no gas, consult your supplier. Display Burner On Indicator Check electricity to the boiler is switched on. Boiler operating satisfactorily. Is the Central Heating System Pressure needle in the GREEN section, between and.5? Does the display show an error code e.g. E, E0? 0 If the reading falls below repressurise the system as described in section.. Turn the ON/OFF/ Selector Switch to. If boiler does not Error Code E9 showing low pressure. Baxi Heating UK Ltd 0

9 5.0 Troubleshooting Is the Timer ON and calling for heat? Is the Room Thermostat (if fitted) set high enough? 0 0 5 0 5 Typical examples of external timer 8 7 6 5 CH ON CH OFF Turn Room Thermostat to maximum setting (typical example shown). Ensure timer is set for Central Heating ON (see any instructions supplied with timer). 5 0 5 0 5 CONTACT YOUR INSTALLER OR SERVICE ENGINEER. If you don t know what you need to do to get the boiler to light, or need help with the system and controls, contact your installer as soon as possible. Baxi Heating UK Ltd 0 5

.0 Repressurising System Fig. Fig. Fig. 0 0 Normal Pressure Requires Repressurising 0 Fault. Central Heating System Pressure. The normal operating water pressure is between and.5 (Fig. ). If the pressure exceeds the safety pressure valve will operate and a fault is indicated. Contact your installer.. It may be necessary to repressurise the system occasionally (Fig. ). A filling device (the filling loop) will be fitted on the system.. If you are unsure of its position, or cannot identify it, consult the installer who fitted the boiler.. The filling loop consists of two taps and a separate metal braided hose with connection fittings. 5. Only when repressurising should the hose be connected between the two taps. Ensure that the nuts on the pipe ends are tightened onto the taps. 6. Fully open one of the taps first, and then while watching the pressure gauge, carefully open the second tap. 7. When the needle on the gauge is indicating or more turn both taps off. 8. Disconnect the metal braided hose from the taps (a small amount of water may be present) and remove it. Keep the hose in a safe place for future use. 6 Baxi Heating UK Ltd 0

.0 Clearances 5mm Min 50mm 5mm Min 00mm Min (00mm Min if using 80/5mm flueing system. For your Safety. This appliance must have been installed in accordance with the manufacturer s instructions and the regulations in force.. Any modification that may interfere with the normal operation of the appliance without express written permission from the manufacturer or his agent could invalidate the appliance warranty. In GB this could also infringe the Gas Safety (Installation and Use) Regulations. GB - Heating Industry definition meaning England, Scotland, Wales, Northern Ireland, Isle of Man and the Channel Isles. Your boiler must not be operated without the casing correctly fitted. 780mm. Do not interfere with any sealed components on this boiler. 5. Take note of any warning labels on your boiler. 6. Your boiler should have the following minimum clearances for Safety and Maintenance (Fig. ):- 50mm Min* Top Bottom Left side Right Side Front - 00mm - 00mm - 5mm - 5mm - 5mm (In Operation) - 50mm (For Servicing) *This is the MINIMUM recommended dimension. Greater clearance than this will aid installation and maintenance. 7. If your boiler is installed in a compartment, do not use it for storage purposes. Do not obstruct any purpose provided ventilation openings. 8. Flammable materials must not be stored in close proximity to your boiler. 9. Avoid skin contact when your boiler is in operation, as some surfaces may get hot e.g. pipework. 50mm Min For Servicing Purposes 0. Ensure that the flue terminal, outside the house, does not become damaged or obstructed, particularly by foliage.. It is important that the condensate drain system is not blocked, modified or damaged in any way as this would affect the operation of your boiler. Your installer should have insulated any exposed pipework. 5mm Min Fig. In Operation Baxi Heating UK Ltd 0 7

5.0 Care of the Boiler 5. Cleaning the Outer case The painted panels should be wiped with a damp cloth and then dried completely. DO T USE ABRASIVE CLEANING AGENTS. 5. Protection & Precaution. The boiler incorporates an integral frost protection feature that will operate when the selector switch is in the ( ) position. If the boiler temperature falls below 5 C, then the boiler will operate until the water temperature has been raised.. If a system frost thermostat has been fitted (your installer will be able to advise you), then to operate correctly and protect your system, the gas and electricity must be left on and the appliance set in the central heating mode.. The boiler incorporates an integral pump protection feature which continually monitors the time since the pump last operated. To prevent seizure, the pump will operate for approximately minute if it has not run in the last hours. 5. Fault Indication 0. If a fault occurs on the boiler an error code may be shown on the facia display (Fig. 5). Display. The codes are either two or three digit, preceded by the letter 'E'. For example, code E will be displayed by 'E' alternating with ''. E50 is shown as 'E' then '50'. Then. E0, E8, E50, E5 & E60 indicate faulty components. You should make a note of the displayed error code and contact your installer or service engineer. Table of Error Codes E0 E8 E50 E0 E9 E5 E0 E E60 Fig. 5 Central Heating NTC Fault Flue NTC Fault Hot Water NTC Fault Safety Thermostat Operated Water Pressure Switch Not Operated Circulation Fault (Primary Circuit) Flue NTC Operated Interruption Of Gas Supply or Flame Failure Fan or Fan Wiring Fault. If E0 or E0 is displayed overheat of the primary water or flue system has occurred. Turn the selector switch to the reset position and hold for at least 5 seconds. If the boiler does not relight, or the code is displayed regularly contact your installer or service engineer. 5. E9 is displayed when the primary water pressure is less than 0.5. After repressurising the system the boiler should operate. Your installer will be able to advise you about the method of repressurising. See page 6 for further details. 6. E indicates that the gas supply has been interrupted, ignition has failed or the flame has not been detected. Ensure that the gas supply has not been turned off, and turn the selector switch to the reset position and hold for at least 5 seconds. If the boiler does not relight, or the code is displayed regularly contact your installer or service engineer. 8 Baxi Heating UK Ltd 0

6.0 Legislation 6. Installation, Commissioning, Service & Repair. This appliance must be install in accordance with the manufacturer s instructions and the regulations in force. Read the instructions fully before installing or using the appliance.. In GB, this must be carried out by a competent person as stated in the Gas Safety (Installation & Use) Regulations.. Definition of competence: A person who works for a Gas Safe registered company and holding current certificates in the relevant ACS modules, is deemed competent.. In IE (Eire), this must be carried out by a competent person as stated in I.S. 8 Domestic Gas Installations. Lifting - This product should be lifted and handled by two people. Stooping should be avoided and protective equipment worn where necessary. Carrying & lifting equipment should be used as required, e.g. when installing in a loft space. All Gas Safe registered engineers carry an ID card with their licence number and a photograph. You can check your engineer is registered by telephoning 0800 08 5500 or online at www.gassaferegister.co.uk The boiler meets the requirements of Statutory Instrument The Boiler (Efficiency) Regulations 99 No 08 and is deemed to meet the requirements of Directive 9//EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels:- Type test for purpose of Regulation 5 certified by: Notified Body 0085. Product/Production certified by: Notified Bodies 0086. For GB/IE only. 6. Benchmark Commissioning Checklist. Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation. The installer is legally required to complete a commissioning checklist as a means of complying with the appropriate Building Regulations (England and Wales).. All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme. A Building Regulations Compliance Certificate will then be issued to the customer who should, on receipt, write the Notification Number on the Benchmark Checklist.. This product should be serviced regularly to optimise its safety, efficiency and performance. The service engineer should complete the relevant Service Record on the Benchmark Checklist after each service.. The Benchmark Checklist may be required in the event of any warranty work. Baxi Heating UK Ltd 0 9

0 Baxi Heating UK Ltd 0 7.0 Notes

8.0 Emergency Warning! If you smell gas Do not operate light switches Do not operate any electrical equipment Do not use a telephone in the hazardous area Extinguish any naked flame and do not smoke Open windows and doors in the hazardous area Turn off the gas supply at the meter Warn any other occupants and vacate the premises Telephone the National Gas Emergency Service on:- 0800 999 Faulty boiler If it is known or suspected that a fault exists on the boiler, it must not be used until the fault has been corrected by a competent person. In an Emergency If a water or gas leak occurs or is suspected, the boiler can be isolated at the inlet valves as follows; Gas Tap. Using a suitable open ended spanner, turn the square nut on the gas tap through 90 ( / turn) to isolate the gas supply at the boiler (Fig. 6).. The water isolating valves are positioned under the boiler and can be closed by turning their taps to the right towards the wall (Fig. 6). Fig. 6. Call your Installer or Service Engineer as soon as possible. Heating Flow, Heating Return and Mains Water Inlet Isolating Valves Baxi Heating UK Ltd 0

Please complete the boxes below 9.0 Warranty & Service Serial Number Standard Warranty Term & Conditions Months Free Warranty - register today To receive your months free warranty please complete the form supplied with the boiler or simply call heateam, the service division of Baxi Heating UK Ltd on 0800 7 6. Date of Installation D D M M Y Y Installer Details (name, address and contact number(s)) Our promise to you If you experience a fault with your new boiler, we aim to provide a safe and high quality repair service supported by our dedicated national network of highly skilled engineers. If your installer can t resolve the problem for you, we will do everything we can to get an engineer out to you as quickly as possible. Nothing in this warranty will affect your statutory consumer rights. What you need to do if you experience a problem with your heating system or the operation of the boiler You should always contact your installer first, because the fault may not be related to the boiler. If your installer confirms that the fault is within the boiler it self and he/she can t repair it, our friendly customer service team is on hand to help. Simply call our service division heateam on 08 87 560 to book an engineer visit or for any general advice that you may need. Our contact centre is open Monday to Friday 8am - 6pm, weekends and Bank Holidays 8.0am - pm, excluding Christmas Day and New Years Day. When calling heateam it would be helpful if you could have the following information to hand:- boiler serial number (see opposite). boiler make and model number. Your installer name and address details. Proof of purchase (if you do not have the boiler serial number). What this warranty covers Free of charge repair or replacement of components found to be faulty from manufacture. Free of charge replacement of the complete unit provided always that the failure is related to a manufacturing fault that cannot be repaired or is uneconomic to repair. The warranty runs for months from the date your product is installed. What this warranty does not cover Repairs to boilers which haven t been installed and commissioned properly, and as set out in the installation instructions (this includes the need to flush the system effectively and add a suitable corrosion inhibitor). Any damage caused by hard water scale deposits and/or aggressive water resulting from corrosion. Any other defects or failures, either in the connected heating system or outside of the boiler itself. Information Label All descriptions and illustrations provided in this leaflet have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request. POTTERTON A Trading Division of Baxi Heating UK Ltd (87956) Brooks House, Coventry Road, Warwick. CV LL After Sales Service 08 87 560 Technical Enquiries 08 87 555 Website www.potterton.co.uk e&oe Faults caused by inadequate supply of electricity, gas or water to the property. Installations within commercial settings for which this boiler was not designed. Reimbursement of any third party repair or replacement costs that we haven t been told about or agreed with you in advance. Compensation for consequential losses (e.g. loss of earnings, business losses, stress and inconvenience) arising from a production breakdown, including repair delays caused by factors outside our reasonable control. Annual Service To ensure you receive the maximum efficiency from your boiler we recommend your boiler has an annual service so you and your family can continue to enjoy heating and hot water comfort. To arrange an annual service from one of our Baxi Heating UK Ltd heating experts, please call 08 87 55 Baxi Heating UK Ltd 0 Comp N o 5 - Iss 0-7/