Installation, Mounting and Maintenance DISA-300

Similar documents
Cooling Strip Model SPB

Additional operating instructions according to ATEX 2014/34/EU Ceiling Impulse Diffuser Model PIL

Fire protection unit

BSK-RPR Fire Damper. Additional operating instructions according to

Fan Coil Unit CULTRA

BKA-EN Fire Damper. Additional operating instructions according to

Installation and operating instructions. DK energy storage and DK energy buffer

Units for suspended ceilings

FSW300 Series Flow Switch

Ceiling diffusers. Type DLQL

Units for suspended cei lings

Technology for life. Unit heater LH

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

DURANGO 12V Heater HF

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Tornado Operations & Maintenance Manual

Halton Rex 600 Basic R6B - Active chilled beam

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Propane Heater REMKO PGM 30 REMKO PGM 60

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Decentralised ventilation units

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Installation Instructions. Mira LED Light System

Installation, Operation and Maintenance Manual

52 BERKSHIRE CEILING FAN

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

General Maintenance and Operating Instructions for Heat Exchangers

Ceiling swirl diffusers

Thermostatic valves with radiator connection systems

breeze easytm model # F100-1W

Ceiling swirl diffusers

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

INSTALLATION, USE AND MAINTENANCE MANUAL HIGH PRESSURE FAN COIL FOR PROFESSIONAL APPLICATIONS, BUILT-IN VERSION

Installation & Operation Instructions Nr _EN_Manual

REMKO CLK Mobile automatic heater

Operating instructions

HEATING AND VENTILATION

GLEB Kitchen exhaust fan

KLIMA Active Chilled Beams

Model K 330 M Part No

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

Model K 520 M Part No

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Halton Rex for Vario R6O - Variable air volume chilled beam

TopVent Design Handbook

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Halton CHB Active chilled beam with boost function for bulkhead installation

Multilux 4-Eclipse-Set

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se

ORIGINAL INSTRUCTIONS

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Model K 280 M Part No

READ AND SAVE THESE INSTRUCTIONS

DH-Direct Fired Poultry Farm Diesel Heater

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

CE Unit is suitable for material transport. The transported gas may be up to 80 C.

Operating Instructions. Rotating Vacuum Filter Type VRF

HOT WASHER MODEL NO: KING150

TFV 900 OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN

51AKB / 51 AKC OWNER S MANUAL

Mikrotherm. Manual Radiator Valves With presetting

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

Owner s Guide and Installation Manual

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

K 3.97 M. Specifications or visit our website: In USA call: Part No

Installation & Maintenance Data IM Contents

FLOW-THROUGH FURNACE HUMIDIFIER

Vitronic 9 / 18 / 36. Operating instructions Notice d emploi Instrucciones de uso

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

Model K 240 plus Part No

FIGURE 1 MODEL RFIII ECLH CONCEALED HSW SPRINKLER ASSEMBLY AND FEATURES. 5/16" (7,9 mm) MIN. 9/16" (14,3 mm) MAX.

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

System architecture. Air treatment Index

OPERATION MANUAL Air Curtains MultiMAXX HT. Air Curtains for Industrial Application

Hoshizaki America, Inc.

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Downrod. Blades. Maintenance & Cleaning.

WOLF VENTILATION SYSTEM PRICE LIST

Instructions for installation

CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE:

Pneumatic agitator A MAN R

Installation instructions

Installation Instructions

L24TWS. Beverage Tower Kit Components. L24TWD Lynx Beverage Kits Model L24TWS Single Tower and L24TWD Double Tower

DUST EXTRACTOR INSTRUCTION MANUAL. 550W (3/4 HP) INDUCTION MOTOR 1850W AUTOMATIC POWER OUTLET 65L COLLECTION BAG ø100mm X 2.

Transcription:

Installation, Mounting and Maintenance DISA-300 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de

Contents Safety instructions...3 General information... 3 Warranty...3 Recycling...3 General information...4 Identification of the delivered model... 4 Function... 4 Installation and commissioning...5 Operating conditions... 5 Material reception... 5 Transport, lifting and handling... 5 Storage... 5 Installation... 6 Mounting... 6 Hydraulic connections... 7 Connecting the air ducts... 7 Mounting accessories... 8 Adjustment of the air deflection blades... 8 Checks... 8 Maintenance...9 Disassembling the units... 9 Air ducts and plenum box... 10 Grilles... 10 Registers... 10 Checking the primary volumetric flow... 11 Troubleshooting... 12 Z11/23-2

Safety instructions Prior to installation and commissioning of this device, please read completely through this manual. Please observe in particular the regulations and operating instructions containing the hazard symbols and safety signs. Their non-observance may result not only in damage to the device but also in light and serious personal injury. If, after reading through the manual, you have further questions, please contact the manufacturer or the local sales office. General information - The inspection, installation, hydraulic connection and commissioning of the device must be carried out by qualified skilled personnel only in compliance with the current regulations. - Electric and hydraulic connections and their correct functioning are the responsibility of the installer. - Do not change any control or safety elements without prior approval by the manufacturer or the local sales office. SCHAKO shall not give any warranty for damage resulting from: - Improper use caused by ignoring the instructions given in this manual - Non-observance of the operating conditions of the device. - Installation and maintenance by personnel without proper qualification. - Improper use of the device or operation under conditions not conforming to the manual. - Use of spare parts that are not original spare parts. Hazard warning Important information Safety information Recycling It is recommended keeping this manual at a safe location after installation and use it for future maintenance activities. Warranty The device warranty will be for two years starting from the handover date and shall apply to all production faults. Electric components are excluded from the device warranty. However, they are covered by the corresponding warranty of the relevant manufacturer Also excluded from the warranty is damage to the device unit caused by components that are not part of the device itself. The warranty only covers the return and replacement of defective materials. Recycling It is recommended recycling the components of the device at the end of the device service life as completely as possible or use them for a different purpose. Components that cannot be recycled must be properly disposed of by an authorized disposal company in accordance with current legal regulations. Z11/23-3

General information Identification of the delivered model The ceiling induction diffuser type DISA-300 is available in four different nozzle configurations: A, B, C and D, different device lengths and air directions (-1 or 2 supply air slots). DISA-300-1 / DISA-300-2 1 5 2 End pieces (4): Sheet steel painted to RAL 9010. Hydraulic connections (5): Upon customer request, the hydraulic connection to the registers can be established either on the left-hand (-WS1) or right-hand side (-WS2) of the unit. Function The primary air (1) supplied from the plenum box induces secondary air in the room (2), which is cooled or heated via the register (3). The primary air is mixed with the cooled secondary air. The combined (4) primary and secondary air flows are supplied to the room at low velocity via 1 or 2 supply air slots. Schematic diagram of the mode of operation DISA-300-1 DISA-300-2 3 4 1 1 4 4 Housing (1): Galvanised sheet steel, with 1 or 2 connection pipes of DN 98, 123 (standard) and ø 148 mm, horizontal (-H) or vertical (-V) position of the connection pipes. 3 3 2 2 Connection pipe position Vertical (-V) Connection pipe position horizontal (-H) Schematic diagram of the jet path DISA-300-1 DISA-300-2 Register (2): 2-pipe (-H, standard) or 4-pipe register (-HT, optional) for cooling and heating. The registers consist of copper pipes 12 mm in thickness, aluminium ribs and a steel frame. Grille (3): Possible designs: perforated sheet grille made of galvanised sheet steel (perforated sheet grille models: -SR, -SQ, - RE and -OB) made of extruded aluminium profile (-PA). Both painted to RAL 9010 (white, standard). DISA-...-SR DISA-...-SQ DISA-...-RE DISA-...-OB Z11/23-4

Installation and commissioning Operating conditions Prior to installation or commissioning of the device, the following operating conditions must be observed: - Coolant or heating fluid: water or glycols (ethylene or propylene) at a concentration below 60%. - Water inlet temperature: above the dew point up to 80 C (Please note that some quick-action plugs do not work at water temperatures above 65 C) - Air inlet temperature: from 2 to 45 C - Max. operating pressure: 8 bar / 125 C To prevent possible damage during transport, the devices will be delivered ex works on pallets (that correspond to the particular weight and dimensions) wrapped with tapes and transparent plastic film. It is recommended leaving this protection in place until the device is commissioned. The openings of the pipes should be closed with dust caps to avoid dust and entry of dirt. Should manufacture-related damage be detected on the device, please contact your local sales office prior to installation. To prevent deposits and corrosion, the quality of the water for filling the registers must comply with regulations VDI 2035 and DIN 50930. Material reception Upon reception of the materials, the components must be carefully checked, in order to guarantee that no transport damage has taken place. Moreover, the dimensions, composition and number of the identification sticker must be checked as to whether they are as ordered. Identification sticker: Model / Modelo / Modell DISA-300/2/H/OL/SR/A/298/900/1200/M/WS1/H/AS1/123/2E Order nr. / Nº Pedido / Auftragsnr: 2198/09 Date / Fecha /Datum: 22/10/2009 Reference / Referencia / Referenz: Sala 1 Hospital Clínico Comments / Observaciones / Bemerkungen: Read manual of instructions / Lea el manual de instrucciones / Betriebs- und Wartungsvorschriften beachten. Do not drill the machine / Maschine nicht durchbohren / No taladrar la máquina Special attention in the connection nuts-coil / Besondere Vorsicht an der Registerverschraubung/ Especial cuidado en la conexión tuercas-batería. Recycle or arrange the residues according to the current rules / Recicle o gestione los residuos según la normativa vigente. Bitte, entsprechend der gültigen Gezetzgebung recyclen. - 2: Number of supply air slots - 2 supply air slots - - H: 2-pipe system - OL: Without air deflection blades - SR: Foldable perforated sheet, - perforation Ø 6 mm - - A: Nozzle configuration - A - - 298: Width -298 mm- - 900: Nominal length - 900 mm - - 1200: Total length -1200 mm- - M: Housing position - centre - - WS1: Hydraulic connection - left - - H: Connection - horizontal - - AS1: Number of connection pipes - 1 connection pipe arranged - 123: Diameter of the connection pipes - 123 mm - - 2E: Model with two end pieces SCHAKO Iberia, S.L. - Pol. Ind. Río Gállego, C/B, nave 3 - E-50840 San Mateo de Gállego. Transport, lifting and handling Transport and handling of the unit shall take place in the position in which the unit is to be built in later on, unless expressly stated otherwise on the unit. Transport, unloading and lifting of the unit shall take place with the necessary care and using tools that are appropriate for the weight and dimensions. NL 900 1200 1500 1800 2100 2400 2700 3000 Weights (1) (kg) 13 17 20 24 27 31 34 38 (1) Standard unit: housing + slot + grille and heat exchanger (empty) The unit shall only be held in position or moved by holding on to the housing. The weight must not rest on the water connections. SCHAKO cannot be held liable for damage to the unit caused by improper handling or handling not mentioned here, loading or unloading. Storage If the device is not installed immediately after its reception, it must be stored according to the following instructions: - The device must be stored at a dry, clean, safe location where no damage to the device can occur, i.e., outside corrosive atmospheric influences. - Leave the protections attached ex works (film, tapes, pallets, etc.) on the device, unless they have already been removed beforehand. - Cover the device with tarpaulins, in order to protect it from dust, moisture and extreme temperatures. - Entries, openings and pipes must be hermetically sealed with dust caps. Z11/23-5

Installation The ceiling induction diffuser type DISA-300 is particularly suitable for horizontal installation in low false ceiling heights. The devices must not be installed in places with extreme moisture (e.g. laundries or swimming pools), with high dust formation, outdoors or in places subject to explosion hazards. For correct installation, the following instructions must be followed: - Make sure that places that are intended as openings for air admission and air discharge are free of pipes, electric cables, crossbeams, stands, etc. - Install the unit at a site that has good air quality. - Make sure that wall and ceiling correspond to the weight of the device and also allow correct mounting of the fastening elements in the ceiling. - The installation site must have sufficient space and the necessary resources for carrying out mounting and maintenance activities of all device components. Make sure that the valves are easily accessible. - The hydraulic pipes should be attached above the device. Mounting The induction diffusers are mounted to a load-bearing ceiling construction using threaded bars, nuts and an M8 washer. Band design For the installation of the device, use adequate tools, devices and materials and observe the safety regulations and other current regulations. SCHAKO cannot be held liable for damage resulting from faulty installation or the use of unsuitable fastening devices. NL-179 La Lc Lc La a c b c a 254,5 NL (mm) La (mm) Lc (mm) During mounting the end of the register pipes must be sealed to protect them from dust and dirt. V H 1 2 connecting connecting piece pieces 900 - a a a 1200 - a a a 1500 - a a a 1800 - a a a 2100 25 234 a,b a,c a,b 2400 217 a,b a,c a,b 2700 206 a,b a,c a,b 3000 198 a,b a,c a,b - Aligning the devices - Inserting and approaching the connection elements between the profiles - The connection parts are delivered with the device Z11/23-6

Hydraulic connections Upon customer request, the hydraulic connection to the registers can be established either on the left-hand (-WS1) or righthand side (-WS2) of the unit. DISA-300-1-...-WS1 When making the hydraulic connections, you have to use suitable tools to avoid excessive tightening or twisting of the register connections. 86 45 49 86 45 Heating Cooling 11 In order to achieve a uniform cooling capacity, the ceiling induction diffusers type DISA-300 should be connected to the cold water distribution system in parallel. The ceiling induction diffusers type DISA-300 are induction devices for "dry cooling". To avoid condensates, the water inlet temperature should be higher than the dew point. DISA-300-1-...-WS2 45 86 7 45 86 30 Heating Cooling When charging the register, make sure by means of on-site ventilation devices that no air remains in the hydraulic circuit. If the unit is to be installed at a location having temperatures below zero degrees, glycol must be admixed to the coolant in a suitable ratio, to ensure that the freezing point of this liquid always stays below the minimum temperature of the operating site. Please note that the use of an antifreeze necessarily results in a loss in performance of the register. DISA-300-2-...- 66 66 28 66 66 9 Connecting the air ducts The air ducts are attached by using pipe clamps, fixing lugs or the like. Heating Cooling Amount of water of the registers: Water capacity (litres) NL DISA-300-...-HT Heating Cooling DISA-300-...-H 900 0,2 0,6 0,8 1200 0,3 0,8 1 1500 0,3 1 1,3 1800 0,4 1,2 1,6 2100 0,5 1,4 1,8 2400 0,5 1,6 2,1 2700 0,6 1,8 2,4 3000 0,7 2 2,7 Optionally, a rubber lip seal can be installed on the connection pipe, to ensure tightness between the device and the pipes. The connection of the hydraulic connections can be done by soldering, pressing (in connection with supporting sleeves) or by means of flexible hoses resistant to oxygen diffusion and pushfit systems. The use of flexible hoses is subject to the manufacturer's specification. Z11/23-7

Mounting accessories Valves and actuators Valves and actuators shall not be installed ex works. During installation the manufacturer's specifications must be observed. Temperature controls The temperature controls are mounted in accordance with the selected model. This is why the instructions enclosed with each model must be followed. However, in order to achieve optimum measurement by the sensors, the following basic information should be observed: - Do not mount the temperature control close to or above a heat source (direct sunlight, lamps, television sets, radiators, etc.), in places with draught air or directly opposite to an air diffuser grille. Adjustment of the air deflection blades To regulate the air flow, rotate the air deflection blades manually. With blockwise adjustable blades, 5 blades can be adjusted simultaneously. - Temperature controls must be mounted at least 1.5 metres above the floor. - Mounting temperature controls on walls toward the outdoors should be avoided. Prior to drilling, make sure that at the location in the wall where the temperature control is attached no electric cables are present. Condensate monitor The installation of a condensate monitor depends on the selected model. Please follow the instructions enclosed with each model. Faulty mounting of the sub-assemblies and of the accessories of the unit can result in a substantial power loss of the unit. The adjusting angle of the air deflection blades must not be more than ± 45, in order to guarantee its function. At an adjusting angle of the air deflection blades outside the straight air throw of up to 45, the cooling capacity of the heat exchanger is reduced by up to 5%, and the horizontal throw is reduced. Checks Prior to commissioning, the following items must be checked or guaranteed: - Hydraulic connections were tightened properly and exhibit no leaks. - Connecting and fastening elements have been sufficiently tightened. - Adequate access for carrying out the maintenance activities has been provided. - Use the on-site ventilation devices to ensure that no air remains in the register and the water circuit. After carrying out the items described above, the correct fastening of the unit must be checked. During commissioning itself, the following items must be guaranteed: - The connecting and fastening elements have been sufficiently tightened. - In heating mode, the temperature of the discharged supply air is not above 40 C. Z11/23-8

Maintenance For reasons of safety, the power supply and hydraulic circuit must be disconnected prior to any maintenance activity. If the unit was operated in heating mode, you have to wait until the register has cooled down. DISA-300-1-H When performing maintenance activities, it is recommended wearing personal protective equipment, in order to avoid cuts and other injuries produced by sharp and pointed parts. Disassembling the units The entire DISA-300 is equipped with a series of safety locks which allow the grille to be folded down via a rotating mechanism on one of the profiles for safe execution of maintenance. The unit is dismounted as follows: - Open the safety locks. - Fold the grille down and remove it. - This makes the grille and the registers freely accessible for cleaning purposes. - After completing the maintenance activity, you must move the grille again to its original operating position and then close the safety locks again. DISA-300-2-H Z11/23-9

To avoid accidental rotation or folding down of the grille, please check that the locks are properly closed. For reasons of safety, the power supply and hydraulic circuit must be disconnected prior to any maintenance activity. Air ducts and plenum box Clean them by blowing compressed air through them or using non-aggressive cleaners. Registers To guarantee the technical characteristics of the device, the registers and heat exchangers must be kept in good clean condition. To ensure this, the following maintenance activities must be carried out: - If the register is dirty, clean it by spraying it with water or compressed air or by evacuation. - Please do not use any scouring agents for cleaning since these materials may impair or damage the DISA-300 (galvanised steel, aluminium and copper) and the surface coatings (paints and anodised surfaces). - If there are larger differences in distance between the ribs, they must be "combed". - Ventilate the hydraulic circuits of the register. In doing so, watch out for possible leaks of the hydraulic system. If condensates are detected, interrupt the hydraulic circuit and find the possible cause of the problem. Grilles Clean them by blowing compressed air through them or using non-aggressive cleaners. When decommissioning the unit or shutting it down for a longer period in winter, the water must be drained from the unit, in order to avoid damage to the register due to the formation of ice. If you want to use antifreezes, you must first determine the freezing point. After recharging the register, the installer has to make sure by means of on-site ventilation devices that no air remains in the hydraulic circuit. Z11/23-10

Checking the primary volumetric flow The supplied primary volumetric flow can be simply checked by checking the static pressure with a Pa meter and the measuring tube available from us as accessory. To this end, one end of the measuring tube fitted with a rubber cap is pressed against the air outlet of one of the nozzles at the primary air plenum box (see drawing) and the other end is connected to the hose connection of a Pa meter. The values read on the meter and the following formula can be used to determine the volumetric flow: V = K Ps V [l/s] = Primary air flow Ps [Pa] = Static pressure The K value is taken from the following table: NL (mm) Nozzle configuration 900 1200 1500 1800 2100 2400 2700 3000 A 0,42 0,62 0,79 0,99 1,16 1,32 1,51 1,69 B 0,71 1,06 1,35 1,69 1,98 2,27 2,59 2,90 C 1,32 1,96 2,50 3,14 3,68 4,21 4,80 5,39 D 1,97 2,92 3,72 4,67 5,48 6,28 7,15 8,03 The Pa meter is not included in the delivery. Nozzle configuration A Nozzle configuration B P (Pa.) 0 20 40 60 80 100 200 300 900-A 1200-A 1500-A 1800-A 2100-A 2400-A 2700-A 3000-A 0 20 40 60 80 100 200 300 Vzu (m 3 /h) P (Pa.) 0 20 40 60 80 100 200 300 900-B 1200-B 1500-B 1800-B 2100-B 2400-B 2700-B 3000-B 0 20 40 60 80 100 200 300 Vzu (m 3 /h) Z11/23-11

Nozzle configuration C Nozzle configuration D P (Pa.) 0 20 40 60 80 100 200 300 900-C 1200-C 1500-C 1800-C 2100-C 2400-C 2700-C 3000-C 0 20 40 60 80 100 200 300 Vzu (m 3 /h) P (Pa.) 0 20 40 60 80 100 200 300 900-D 1200-D 1500-D 1800-D 2100-D 2400-D 2700-D 3000-D 0 20 40 60 80 100 200 300 Vzu (m 3 /h) Troubleshooting Problem Possible cause Solution Air inlet and outlet of the inner unit clogged Remove foreign material and clean the unit Air in the interior of the register Ventilation of the hydraulic system Please inform the installer The unit does not cool or heat sufficiently The unit is losing water The unit is working with too much noise Installed unfavourable or malfunctions at the temperature control or sensor Install thermostat in a different place Clogging in the interior of the unit or at the air inlet Remove foreign material and clean the interior of the unit Condensate in the register Modify the register water inlet temperature The water circuit of the register is leaking Register damaged Please inform the installer Incorrect valve or hydraulic connection The air intake or air blow openings or the lines are clogged. Remove foreign material and clean the unit Loose screws and fastening elements Tighten screws Foreign material or dirt on register surface Remove foreign material by careful brushing Z11/23-12