QUINCY QPNC SERIES NON-CYCLING QUINCY QRHT SERIES HIGH TEMP

Similar documents
REFRIGERATED AIR DRYERS

ECO DRI CYCLING REFRIGERATED AIR DRYERS 100 TO 8000 CFM

AIR COMPRESSOR Hp

REFRIGERATED AIR DRYERS

QUINCY QGV SERIES hp

the responsibility is yours!

QUINCY QGS SERIES hp

QUINCY QGS SERIES hp

Performance You Demand. Reliability You Trust. QUINCY QSI POWER$YNC SERIES ROTARY SCREW VARIABLE DISPLACEMENT COMPRESSORS HP

QGB QUINCY QGB SERIES ROTARY SCREW AIR COMPRESSORS HP

AIR COMPRESSOR Hp

QGB QUINCY QGB SERIES ROTARY SCREW AIR COMPRESSORS HP

The Science of Compressed Air

QUINCY QST/B SERIES ROTARY SCREW AIR COMPRESSORS HP

QR-25 QUINCY QR-25 SERIES RECIPROCATING AIR COMPRESSORS 1 25 HP

Condensate Management. Condensate Purifiers Condensate Drains

QUINCY QOF SERIES OIL-FREE AIR COMPRESSORS QOF 2-30 HP

Oil-Free Compressors. Oil-Free Compressors. Quincy QOF Series Oil-Free Air Compressors QOF 2-30 HP

Desiccant Dryers. Desiccant Dryers. Heatless Heated Purge Blower Purge Modular

Refrigerated Air Dryers

Refrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm

Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

RN SERIES REFRIGERATED COMPRESSED AIR DRYERS NON-CYCLING REFRIGERATEDERATED COMPRESSED AIR DRYERS SCFM

QGS Series. QGS Series. Rotary Screw Compressors hp

20 21,250 SCFM GLOBAL AIR TREATMENT. FIL Series

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers

next generation R 1 cycling refrigerated compressed air dryers flow capacity: scfm ( Nm 3 /hr)

CNC Series Refrigerated Air Dryer CFM

RHP & FHP Series. High Pressure Air Treatment Global Air Treatment

Energy Saving Refrigerated Air Dryers SRC Cycling Dryers

SR Series Refrigerated Dryers SCFM

UA Series Air Dryers. 10 Year Warranty Limited ( SCFM) Setting a new standard in Quality and Reliability WAS 360

RN SERIES REFRIGERATED COMPRESSED AIR DRYERS NON-CYCLING REFRIGERATED COMPRESSED AIR DRYERS SCFM

ThermoStar Refrigeration Air Dryers

UA Series Air Dryers. 10 Year Warranty Limited ( SCFM) Setting a new standard in Quality and Reliability WAS 360

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

RNC Series SCFM Global Air Treatment

Atlas Copco Stationary Air Compressors. GA30-90C WorkPlace Air System TM 30-90kW/40-125HP oil-injected rotary screw compressors

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

HYDROGARD Refrigerated Air Dryers HGD and DES Series

RDS SERIES REFRIGERATED COMPRESSED AIR DRYERS ENERGY SAVING REFRIGERATED COMPRESSED AIR DRYERS SCFM

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

Nirvana. Cycling Refrigerated Dryers

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

HIGH INLET TEMPERATURE REFRIGERATED AIR DRYERS. GHRN Series

Ingersoll Rand. Rotary Screw Air Compressors 5-15 hp (4-11 kw)

HX Series. Compressed Air Dryers 10 to 2400 scfm. Setting a new standard in Quality and Reliability DRYMAX DRYMAX DRYMAX

THERMAL MASS CYCLING REFRIGERATED AIR DRYERS. GTRC Series

Compressed Air Filters

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

Refrigerant air dryers. FD series ( l/s, cfm)

Refrigerated Compressed Air Dryers

RNC Series SCFM Global Air Treatment

DGH Series Global Air Treatment

HEATLESS DESICCANT AIR DRYERS

Atlas Copco. Heat-of-compression rotary drum dryers ND series ( l/s, cfm)

F-H Refrigerated Dryers

CFH Series High Efficiency Filters

CDT Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Heatless Desiccant Air Dryers 40 5,400 SCfm

CHC Series High Capacity Refrigerated Dryer 2,000 20,000 SCFM

Dual Tower Heat Reactivated Desiccant Air Dryer

MANUFACTURED with high-quality components and innovative techniques. DESIGNED for economical, trouble-free performance and long-life reliability

Fixed Speed Rotary Screw Compressors UP6 Series 4-11 kw (5-15 hp)

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series

The Quincy QMB and QMT: A new approach to the modular advantage

High-Capacity Cycling Refrigerated Compressed Air Dryer. RTM Series

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

Desiccant Air Dryers. Heatless, Heated and Heated Blower

Externally Heated Desiccant Air Dryer RP Series

ES-6. Encapsulated Rotary Screw Air Compressors. 4 7 kw 5 10 hp

Spiralair SPR 2-30 TECHNOLOGY YOU CAN TRUST

600-10,000 scfm AES Series. AES Series Energy Saving. Refrigerated Air Dryer ,000 scfm. Front Page

Heatless Air Dryers AIRTEK PREMIUM PRODUCTS FOR INDUSTRY. TW Series

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

Regenerative Desiccant Dryers. KAD, KED, KBD and Hybritec Series

Refrigerated Dryers. Cycling; Non-Cycling; High Pressure; High Temperature ,000 scfm

MODULAR HIGH CAPACITY REFRIGERATED AIR DRYERS. GMRN & GMRC Series

industry revolves around VMMD Series Membrane Air Dryer

Ingersoll Rand 5-15 hp. Rotary Screw Compressors

RSD Series Energy Saving Refrigerated Dryers CFM Global Air Treatment

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Rotary screw Air compressors. Fixed Speed 5 15HP

EXTERNALLY HEATED BLOWER PURGE DESICCANT AIR DRYERS. GBPD Series

Distributed by: 2008 Ingersoll-Rand Company CCN IRITS

MultiPlex INNOVATIVE COMPRESSED AIR SOLUTIONS LARGE CAPACITY TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS

SSB Blower Purge Desiccant Dryers SSE Heat Reactivated Desiccant Dryers 220 to 10,500 scfm

NEW INTELLIGENT AIR TECHNOLOGY

CMMD Series Membrane Air Dryer

CRV Variable Operation Refrigeration Dryers scfm

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

Heat Les Desiccant Compressed Air Dryers. DSE Series DSS Series DHD Series

REFRIGERATED AIR DRYERS SCFM. CRPC Energy Saving Series

25 30 HP ROTARY SCREW COMPRESSORS. Apex Series

Flexible Solutions for Air Quality

Global Leader in Efficiently Treating Compressed Air EXCELLENCE IN DESIGN, MANUFACTURING AND SERVICE

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

CRN Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Refrigerated Compressed Air Dryers

Atlas Copco Oil-injected Rotary Screw Compressors GA 15-22/GA /GA VSD (11-30 kw/15-40 hp)

Transcription:

QUINCY QPNC SERIES NON-CYCLING QUINCY QRHT SERIES HIGH TEMP

REFRIGERATED AIR DRYERS NON-CYCLING DESIGNS FOR MAXIMUM SYSTEM EFFICIENCY NON-CYCLING DRYERS 10 TO 3000 CFM Quincy refrigerated air dryers are manufactured to exact standards in state-of-the-art production facilities, featuring high capacity, balanced component selection and consistent output. This, combined with a clean, simple design, creates an efficient, reliable and environmentally friendly non cycling refrigerated air dryer. Quincy refrigerated air dryers allow plant equipment to run efficiently, and processes more reliably, by providing the cleanest compressed air utility possible. Payback starts immediately upon start up. ENVIRONMENTALLY SAFE REFRIGERANTS No CFC s or HCFC s EPA/SNAP Compliant Zero Ozone Depletion Potential (ODP) Qualifies for one LEED point Higher performance potential Higher efficiency potential 2 QuincyCompressor.com Performance You Demand. Reliability You Trust.

QPNC NON-CYCLING DRYER OPERATION Quincy Non-Cycling dryers use a two-stage heat exchanger system to maintain consistent dew points. Freeze-ups are prevented and optimum performance is maintained by integrating the highest quality components and refrigeration controls into our system. The system reduces the temperature of the compressed air to approx. +39 F forcing entrained moisture to condense. The mixture of condensed liquids and cold air then flow into the cold point moisture separator where the liquids are collected and removed by a Zero Loss condensate drain. The Zero Loss drain ensures maximum moisture removal while saving energy. Once liquids have been removed, the cold dry compressed air returns through the cold side of the first stage heat exchanger where it is reheated by the warm incoming air. Pipe sweating is avoided and air volume is increased by reheating. The compressed air is now considered treated and ready for delivery to downstream products. Non-Cycling Flow Schematic Air Out Air In No Loss Drain Superheated Gas TXV Condenser Compressor Liquid Suction Accumulator 3

REFRIGERATED AIR DRYERS EASE OF OPERATION Non-cycling Control Panel 10 250 cfm Non-cycling Control Panel 360 3000 cfm Refrigerant System Flow Run & Alarm Indicator Lights Analyzer Gauge Schematic Stop / Start Switch with Lock Out SAVING ENERGY Quincy QPNC dryers from 10 to 3000 cfm come standard with the most energy efficient ZERO LOSS DRAINS. HEAT EXCHANGERS & MOISTURE SEPARATORS Low pressure drop Cold Air Module (QPNC 75-3000) Brazed Plate (QPNC 10-50) Integrated Moisture Separator Five step centrifugal separation 10-Year Heat Exchanger Warranty 4 QuincyCompressor.com Performance You Demand. Reliability You Trust.

QPNC SPECIFICATIONS & ENGINEERING DATA Non-Cycling Standard Electrics Pressure Dimensions Approximate cfm @ m 3 /hr Volts/Phase Full Load Max Nominal L W H Shipping Connections Refrigerant Model 100 psig 7 bar Hertz kw psig ΔP In. In. In. Wt. lb. In/Out Gas QPNC 10 10 17 115/1/60 0.2 230 1.5 21 14 20 57 0.5 NPT (M) R134a QPNC 15 15 25 115/1/60 0.2 230 2.2 21 14 20 59 0.5 NPT (M) R134a QPNC 25 25 42 115/1/60 0.3 230 2.9 21 14 20 70 0.5 NPT (M) R134a QPNC 35 35 59 115/1/60 0.3 230 2.9 21 14 20 75 0.5 NPT (M) R134a QPNC 50 50 85 115/1/60 0.4 230 2.9 21 14 20 75 0.5 NPT (M) R134a QPNC 75 75 127 115/1/60 0.7 230 2.9 23 18 31 112 1 NPT (F) R404A QPNC 100 100 170 115/1/60 0.9 200 2.2 25 19 32 134 1.5 NPT (F) R404A QPNC 125 125 212 115/1/60 1.0 200 2.9 25 19 32 150 1.5 NPT (F) R404A QPNC 150 150 255 208-230/1/60 1.5 200 1.5 26 23 36 198 1.5 NPT (F) R404A QPNC 200 200 340 208-230/1/60 1.6 200 2.9 26 23 36 198 1.5 NPT (F) R404A QPNC 250 250 425 460/3/60 1.9 200 3.6 26 23 36 198 1.5 NPT (F) R404A QPNC 300 300 510 460/3/60 2.3 188 3.6 38 29 40 282 2 NPT (F) R410A QPNC 360 360 612 460/3/60 2.6 188 4.3 38 29 40 322 2 NPT (F) R410A QPNC 500 500 850 460/3/60 3.2 188 4.3 38 29 40 348 2 NPT (F) R410A QPNC 600 600 1020 460/3/60 4.3 188 4.3 38 29 40 364 2 NPT (F) R410A QPNC 750 750 1275 460/3/60 5.4 188 3.6 41 41 61 717 3 NPT (M) R404A QPNC 1000 1000 1700 460/3/60 5.8 188 4.3 41 41 61 739 3 NPT (M) R404A QPNC 1250 1250 2125 460/3/60 7.3 188 5.0 41 81 61 772 3 NPT (M) R404A QPNC 1600 1600 2720 460/3/60 12.7 188 4.3 40 83 61 1213 6 Flange R404A QPNC 1800 1800 3060 460/3/60 13.7 188 4.3 40 83 61 1235 6 Flange R404A QPNC 2200 2200 3740 460/3/60 19.2 188 3.6 40 83 61 1323 6 Flange R404A QPNC 2500 2500 4250 460/3/60 19.2 188 3.6 40 83 61 1323 6 Flange R404A QPNC 3000 3000 5097 460/3/60 22.3 188 3.7 40 83 61 1433 6 Flange R404A * Water cooled available. Consult factory for data and availability. Notes: Capacity in accordance with recommended NFPA standards and CAGI standard ADF 100. Ratings based on 100 F inlet temperature, 100 psig inlet pressure and 100 F max ambient. kw inputs are shown for air cooled models including fan motors. CORRECTION FACTORS Inlet Air Pressure Correction A PSIG 60 80 100 120 140 150 180 200 QPNC 10-3000 Factor 0.79 0.93 1 1.03 1.07 1.09 1.12 1.14 Ambient Air Temperature Correction C Temp. F 80 90 100 110 QPNC 10-250 Factor 1.12 1.03 1 0.92 QPNC 325-3000 Factor 1.15 1.07 1 0.91 Inlet Air Temperature Correction B Temp. F 80 100 110 120 QPNC 10-250 Factor 1.05 1 0.87 0.67 QPNC 325-3000 Factor 1.05 1 0.84 0.69 Dew Point Correction D Temp. F 37 39 F 45 50 F QPNC 10-250 Factor 1 1.12 QPNC 325-3000 Factor 1 1.2 Example One: Conditions Requirement Capacity Inlet Pressure Inlet Air Temp. Ambient Temp. Dew Point 480 cfm 120 psig 110 F 100 F 39 F Example One: Calculations Dryer Required = cfm required (A) x (B) x (C) x (D) = 480 (1.03) x (.84) x (1) x (1) = 555 cfm dryer required Select QPNC 600 for this application Example Two: Conditions QPNC 500 Corrected Flow for: Inlet Pressure Inlet Air Temp. Ambient Temp. Dew Point 120 psig 110 F 90 F 39 F Example Two: Calculations Corrected Capacity = Std. Capacity x (A) x (B) x (C) x (D) = 500 x (1.03) x (.84) x (1.07) x (1) = 463 cfm QPNC-25 Non-Cycling Dryer 5

REFRIGERATED AIR DRYERS QRHT HIGH TEMPERATURE REFRIGERATED DRYER SPACE SAVING REFRIGERATED DRYER QRHT Series Total Air System High Temperature Dryers integrate five different components that perform separate functions. An air-cooled aftercooler, refrigerated dryer, moisture separator, Zero Loss drain, and coalescing filter. These five components work in harmony to ensure clean dry, filtered compressed air. FPO 180ºF Inlet Temperature 3-in-1 Design Eliminates Water, Oil and Dirt from Air Prevents Damage to Pneumatic Tools Fewer Finished Product Defects Prevents Fisheye Paint Splotches Reduces Operational Downtime Increase Profitability and Productivity Eliminates Air Line Purging QRHT SPECIFICATIONS & ENGINEERING DATA High Temperature Power Dimensions cfm @ Consumption Max L W H Approx Connections Model 100 psig Voltage Kw psig Refrigerant In. In. In. Wt. lb. In. QRHT 25 25 115/1/60 42 232 R134a 21 14 18 57 1/2 NPT QRHT 50 50 115/1/60 84 232 R404A 23 19 31 108 1 NPT QRHT 75 75 115/1/60 169 232 R404A 23 19 31 168 3/4 NPT QRHT 100 100 115/1/60 163 232 R404A 23 19 41 231 3/4 NPT QRHT 125 125 115/1/60 203 232 R404A 23 19 41 236 3/4 NPT Notes: models. Instrumentation includes; On/off switch, refrigerant suction pressure gauge and drain test button. Coalescing filter is supplied for all Inlet Flow SCFM Model 50ºF PDP 40ºF PDP QRHT 25 25 20 QRHT 50 50 40 QRHT 75 75 60 QRHT 100 100 80 QRHT 125 125 100 SCFM flow is rated at 180ºF max. inlet, 100 psig and 100ºF ambient 6 QuincyCompressor.com Performance You Demand. Reliability You Trust.

THE QUINCY PROMISE Quincy Compressor and its partnering distributors promise to provide you with uncompromising reliability in all Quincy equipment. This makes your compressed air system one less thing that you need to worry about, allowing you to focus on your company s productivity and profitability. THE QUINCY SOLUTION Operating at peak efficiency and providing quality product is a priority for many of our customers. Quincy Compressor in partnership with our global network of authorized distributors strives to be your provider for all of your compressed air system needs. From the air compressor to filtration to dryers and storage solutions, Quincy Compressor is your single source provider for all of your compressed air system needs. Air Compressors Quincy Compressor is a premier manufacturer of many different types of air compressors designed for a variety of applications using different compression technologies. The Quincy QT is a Reciprocating Splash Lubricated compressor for tough everyday use. The Quincy QP is a reciprocating fully pressure lubricated compressor for a competitive advantage. The Quincy QR is a reciprocating compressor designed for the most demanding conditions. The Quincy QGS 5-30 HP is a heavy-duty belt driven rotary compressor at a competitive price. The Quincy QSI provides an industrial grade premium fixed speed rotary screw air compressor. The Quincy QGV provides a premium variable speed rotary screw air compressor designed to optimize your energy efficiency. Compressed Air Treatment Quincy Compressor is your single-source provider of compressed air treatment products to complement your air compressor. Quincy provides refrigerated air dryers, desiccant air dryers, compressed air filtration from 5 to.01 micron, condensate drains, condensate management systems, storage solutions, and flow control valves. Quincy Compressor is truly a single-source provider for all of your compressed air needs. Genuine Parts Genuine Parts from Quincy Compressor keep your equipment running like new. When servicing your Quincy compressor, insist on Genuine Quincy parts. Not only will you save time and money, but you will gain the peace-of-mind from using only the highest quality parts worthy of the Quincy name. System Controls Whether you have one air compressor or many air compressors from different manufacturers, Quincy Compressor provides you with a way to control and monitor all of your system components in your compressed air system in a way that maximizes your energy efficiency. Whether you need to control your system on site or from half way around the world, Quincy Compressor is your source for reliable, efficient controls. 7

quincycompressor.com quincycompressor.com COMPRESSED AIR SYSTEMS BEST PRACTICE QSI-500i quincycompressor.com ECODRI Air Quality Classification ISO 8573.1 Solids Moisture Oil Micron ISO PDP ISO PPM ISO 0.01 1 +38 F 4 0.01 1 0.01 1 +38 F 4 0.003 1 Quincy Rotary Screw WSN Bulk Liquid DP1 Wet 1gal/CFM and/or Mist Eliminator DP2 CSN 1 Micron 0.1 PPM DP3 Refrigerated Air Dryer QPNC Non-Cycling QED Cycling DP4 CPN 0.01 Micron 0.01 PPM DP5 Dry 5gal/CFM ACN 0.003 PPM Vapor & Odors 0.01 1-100 F 1 0.001 1 NOTE: Requires CXN (.001 PPM) filter in series with standard CPN prefilter. 1 2-40 F 2 0.01 1 0.01 1-40 F 2 0.003 1 Quincy Reciprocating AC WSN Moisture Separator DCN Particulate/Coarse Coalescer CSN STD 0.1 PPM Coalescer, 1 Micron CPN Polishing 0.01 PPM Coalescer CXN Xtra 0.001 PPM Coalescer ACN Activated Carbon Absorber HTD High Temperature, 1 Micron WSN Bulk Liquid DP6 CPN Desiccant Heatless Air Dryer 0.01 Micron QDTS Small 0.01 PPM QHD Industrial DP7-40 F PDP CSN 1 Micron Particulate Dry 5gal/CFM ACN 0.003 PPM Vapor & Odors QPNC Non-Cycling Refrigerated Dryer QED Cycling Refrigerated Dryer QMOD Modular Heatless Dryer QDTS Small Heatless Dryer QHD Industrial Heatless Dryer QHP Heated Purge Dryer QBP Blower Purge Dryer QRHT High Temp. Refrigerated Dryer AC After Cooler DP Drain Point CPN 0.01 Micron 0.01 PPM DP8 A B Desiccant Heated Air Dryer QHP Heated Purge QBP Blower Purge -40 F PDP CSN (NPT) HTD (FLG) 1 Micron Particulate Dry 5gal/CFM ACN 0.003 PPM Vapor & Odors 1 2-40 F 2 0.01 1 0.01 1-40 F 2 0.003 1 1 2 +50 F 6 0.01 2 Quincy Condensate Purifier QRHT-75 0.01 1 +50 F 6 0.003 1 DCN 5 Micron 5 PPM DP9 High Temperature/ Refrigerated Air Dryer QRHT High Temp. DP10 2012 Quincy Compressor. All rights reserved. Printed in U.S.A. (QPRD-015 07/13) CSN 1 Micron 0.1 PPM DP11 ACN 0.003 PPM Vapor & Odors Approximate Liquid Removal 100 CFM, 100 psi, 80 F, 4000 hrs./yr., 2 PPM Drain Point 1 2 3 4 Gallons Drain per Year Point 3000 2000 305 1300 5 6 7 8 Gallons Drain per Year Point 140 3000 310 310 9 10 11 Gallons per Year 300 4320 120 701 North Dobson Avenue Bay Minette, AL 36507 Phone 217.222.7700 Fax 251.937.7182 Email: info@quincycompressor.com