MiniLine Air Cooled Condensing Units -1/2 to 6 HP

Similar documents
D Series Air Cooled Condensing Units 3 to 22 HP Brochure MAY, 2007

MEA. Air Cooled Condensing Units 3 to 22 HP Brochure September, Visit us on the web:

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Kramersaver Air Cooled Condensing Units

Table A-4...Professional and Do-It-Yourself Improvement Expenditures by Homeowner Characteristics: 2007

Table W-4...Total Improvement Expenditures by Homeowner Characteristics:

horizontal air discharge outdoor discus condensing unit

Griddle Stands REFRIGERATORS & FREEZERS. Call us toll free at (800) INNOVATIVE DESIGNS FOR YOUR FOODSERVICE NEEDS

Tempra / DHC-E. The Finest Tankless Electric Water Heaters Available! Simply the Best Featuring Advanced Microprocessor Control

Table A-4...Professional and Do-It-Yourself Improvement Expenditures by Homeowner Characteristics: 2013

Air-Cooled Condensing Units with Bitzer Compressors

Oklahoma and Texas Interdependency Along the I-35 Corridor

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

T H I R D Q UA R T E R

Air-Cooled Condensing Units with Compact Screw Compressors

Simply the Best WHOLE HOUSE COMFORT SAVE WHOLE HOUSE TANKLESS ELECTRIC WATER HEATERS

Inventory Management Guide

BULK PURCHASE DISCOUNTS Valid for purchases any time of year

Tempra Series WHOLE HOUSE TANKLESS ELECTRIC WATER HEATERS Whole House Comfort

ADDRESS (NO PO BOX) COMMUNICATIONS GENERAL INFORMATION. First Name*: John. Last Name*: Smith. Job Title*: President Company Name*: Custom Homes

F O U R T H Q UA R T E R

Advanced Microprocessor Control The Finest Tankless Electric Water Heaters Available! DHC-E / Tempra

SPECIFICATIONS FOR WALK-IN COOLERS & FREEZERS

Limestone Cements. Why are we doing this? What are they? What s in it for you? Limestone Cements, Holcim (US) Inc.

Installation, Start-Up and Service Instructions

MACH N-407 Heat Pump Air-Cooled Chiller

Space Heating with Solar Energy

MAC N-407 Air-Cooled Chiller

Model VDC Direct-Drive Remote Air-Cooled Condensers

LOW PROFILE UNIT COOLER

Condensing Units CUS 15-60

3-22 HP CONDENSING UNITS Technical Guide

Super-Flo Low Profile Unit Cooler

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional

Simply the Best WHOLE HOUSE COMFORT SAVE WHOLE HOUSE TANKLESS ELECTRIC WATER HEATERS

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

Head Pressure Control Application Guide

LOW PROFILE UNIT COOLER

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

ADVANTAGE SERIES. Popular Technologies for Outdoor Living

roof finish is 26 gauge acrylic coated stucco galvanized steel.080 textured aluminum interior floor finish, where required

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

Commercial High-Efficiency Condensing Units

10-Bilt. Walk-In Coolers & Freezers With Matching Refrigeration Systems FEATURES OPTIONS

Featured Fish-Week ofmay 29th

2018 PRICING. alderonind.com STANDARD PRODUCTS

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Product Chillers A P P L I C AT I O N S

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

J A N UA RY J U N E

PACKAGE AIR CONDITIONER

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

C13-Series Engineering Guide

Commercial High-Efficiency Condensing Units

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Copeland Scroll Outdoor Refrigeration Unit

commercial refrigeration products

Bar Equipment BOTTLE, KEG & BACK BAR COOLERS INNOVATIVE DESIGNS FOR YOUR FOODSERVICE NEEDS

Product Data ERVC. Energy Recovery Ventilators. Features

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

Thermobank Hot Gas Defrost 12 through 70 HP

TECHNICAL SPECIFICATIONS

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

Air-Cooled Split System Condensing Units for Remote DX Coils and Air Handlers. Models RCS 015D to 140D R-410A Refrigerant.

LIST PRICES 1/2-6 HP "KOMPACT" CONDENSING UNITS

This presentation is posted for public use. ACEEE does not endorse any product or service.

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

MODELS B1PA024, 030 AND 036

Installation, Start-Up and Service Instructions

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

CoolSpot Engineering Guide

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

MAC-120HE-03 Air-Cooled Chiller

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

Specifications and Performance S2H

KTL Two-Way Low Profile Evaporators

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Bosch Tankless Water Heater Troubleshooting Guide

High Profile Evaporator

MAXA-MI$ER Energy recovery solutions

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

R4H4. Product Specifications

NOW I 50% OFF. CALL TODAY! H.L. Flake McDonald Dash ORDER ONLINE! HLFLAKE.COM BUY AT LIST PRICE

VertiCool Aurora Engineering Guide

Transcription:

1/2 to 3 HP Commercial Refrigeration MiniLine Air Cooled Condensing Units -1/2 to 6 HP Literature No. - C300.2.2 July, 2007 4 to 6 HP MEA Medium to Low Temperature Units Tecumseh hermetic Carlyle semi-hermetic Compressors

Description Carrier MiniLine condensing units are ideally suited for use in a variety of commercial applications such as cafeterias, convenience stores, restaurants and fast food outlets. MiniLine units offer a winning combination of quality, economy, and flexibility coupled with lower long term operating costs. This low profile product line has been designed around environmentally safer refrigerants. All models utilize R-22 or R-404A. Units are available with a choice of compressors: low cost hermetic and Scroll or heavy duty semi-hermetic. In addition to the basic Indoor and Outdoor models described in this bulletin, Carrier can also provide pre-engineered system packages with matching evaporators and accessories. These MiniLine condensing units are designed for operation in ambient air temperatures up to 110 F. Oversized condensers are available for most models. Contact our Applications Engineering department for requirements exceeding 110 F ambient temperature. Options Features Indoor/Outdoor Models (CSEU/ CSEC/CSEO) Hermetic or Semi-hermetic compressor. Generously sized condenser, Copper tubes/aluminum fins Large electrical control panel for power and control circuits Compressor contactor or start kit Encapsulated high and low pressure controls (adjustable low pressure control on low temp models) Refrigerant receiver with shutoff valve and relief plug All-weather housing UL and cul listed for indoor or outdoor use Optimized Packaged Units (CSLU/ CSLC/CSLO) Includes all Indoor model features - plus: Liquid line kit with filter/drier and sight glass with moisture indicator Suction line piping to exterior of cabinet Low Ambient - flooded head pressure control valve Crankcase heater Electric defrost timer with defrost contactor/relay on low temperature models (ED10-230/1) Air Defrost Timer (2-1/2 through 6 HP High and Medium temp models only, optional for other HP) Factory installed air defrost timer Factory installed electric defrost timer with contactor Low ambient flooded control ( on CSL models) Mild ambient fan cycle control (for 2 fan units only) Wire fan guard(s) kit Suction line piping to exterior of cabinet ( on CSL models) Suction line kit with filter and piping Liquid line (piping only) Liquid line kit with piping, filter/ drier and sight glass ( on CSL models) Suction accumulator Oil separator (not available with mounted accumulator) Crankcase heater Copper fins, or coated condenser coil Tiered stacking Liquid line solenoid Fused disconnect High ambient oversized condenser coil - contact Applications Spring mounting for semi-hermetic compressors MiniLine Small Series Condensing Units Model Style E = Indoor/Outdoor Model L = Outdoor Flooded Model Compressor Type C = Carlyle Semi-Hermetic U = Tecumseh Hermetic O = Copeland Scroll Nomenclature CS L U 500 H 22 E Refrigerant Type 22 = R-22 44 = R-404A / 507 Temperature Range (varies by unit) H = High /Medium (0 to 55 S.T.) M = Medium (-10 to 45 S.T.) L = Low (-40 to 25 S.T.) Horsepower 050 = 1/2 HP 075 = 3/4 HP 100 = 1 HP 150 = 1-1/2 HP 200 = 2 HP Voltage code C=230/60/1 D= 208-230/60/1 E= 208-230/60/3 G= 460/60/3 250 = 2 HP 300 = 3 HP 400 = 4 HP 500 = 5 HP 600 = 6 HP 2

MiniLine Features and Options UNITS PACKAGED UNITS ELECTRICAL CONTROLS CONDENSER PIPING COMPONENTS Receiver HOUSING LOW AMBIENT CONTROLS DEFROST PROVISIONS TESTING DESCRIPTION CSEU CSEO CSEC CSLU CSEO CSLC Hermetic N/A N/A N/A N/A Scroll N/A N/A N/A N/A Semi-Hermetic N/A N/A N/A N/A Oil failure control (as required) N/R N/R N/R N/R Encapsulated high and low pressure controls** Compressor contactor (1Ø or 3Ø), start kit (1Ø) Control transformer (460v to 230V) as required Copper tubes, Aluminum fins Fan motor(s) - overload protection Fan blade(s) - individually balanced Fan guard(s) Suction line ( vibrasorber and piping only) Suction kit (vibrasorber, piping and suction filter) Suction line accumulator *Liquid line kit Discharge vibrasober N/R N/R N/R N/R Replaceable core fliters Hot Gas Bypass Controls Oil Seperator and Suction Accumulator (Both) Shut-off valve(s) Fusible plug Galvanized steel all w eather housing Control panel Fan cycle control (2 Fan models only) Flooded head pressure control Air defrost time clock Electric defrost package OPTIONAL (1) (1) (1) Hot Gas Defrost CONTACT FACTORY CONTACT FACTORY UL and C-UL listed Leak and dielectric tested before shipping Dry Nitrogen shipping charge (25 to 35 PSI) OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL CONTACT FACTORY CONTACT FACTORY CONTACT FACTORY OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL CONTACT FACTORY CONTACT FACTORY CONTACT FACTORY OPTIONAL = Standard Feature N/R = Not Required N/A = Not Available OPT = Optional Feature Vibrasorber not required for Hermetic compressors. Add optional kit SPR-VB if suction vibrasorber required. Standard for 2-1/2 through 6HP Models. For 1/2 to 2HP models, add kit number SPR-VB to include vibrasorbers and compressor spring mounting. *Liquid line kit includes: piping, filter drier, sight glass/moisture indicator. ** Adjustable low pressure control on low temp models in lieu of fixed control. (1) Electric defrost kit is included on Low temperature models. ED-10-230/1 for 1/2 to 3 HP models, and ED11-230/3 for 4 to 6 HP models. 3

Performance Data Hermetic Models 4 0 4 A Physical Data CAPACITY (BTUH) AT 95 o F AMBIENT REC'R CONN. APPROX. MODEL NOM SUCTION TEMPERATURE o F @ 90% FIG. (ODS, IN.) SHIP WT. NUMBER HP +40 +30 +25 +20 +10 0-10 -20-25 -30-40 (LBS) LIQ. SUC. (lbs.) CS*U050M44 0.5 ----- 5660 5110 4550 3470 ----- ----- ----- ----- ----- ----- 5.1 1 3/8 5/8 152 CS*U075M44 0.75 ----- 8150 7450 6790 5550 4290 ----- ----- ----- ----- ----- 5.1 1 3/8 5/8 167 CS*U101M44 1.0 ----- 12150 11240 10310 8430 6610 4980 ----- ----- ----- ----- 8.6 2 3/8 5/8 195 CS*U150M44 1.5 ----- 15290 14060 12830 10410 8030 5680 ----- ----- ----- ----- 8.6 2 3/8 7/8 228 CS*U200M44 2.0 ----- 22570 20910 19350 16330 13520 10340 ----- ----- ----- ----- 8.6 2 3/8 7/8 253 CS*U300M44 3.0 ----- 25790 24190 22260 18090 13490 ----- ----- ----- ----- ----- 13.7 2 1/2 1-1/8 273 CS*U400M44 4.0 ----- 35460 32630 29900 24650 19300 ----- ----- ----- ----- ----- 24.3 3 1/2 1-1/8 390 CS*U500M44 5.0 ----- 40040 36520 33330 27170 21120 ----- ----- ----- ----- ----- 24.3 3 1/2 1-1/8 405 CS*U050L44 0.5 ----- ----- ----- ----- ----- 2760 2100 1590 1250 ----- ----- 5.1 1 3/8 5/8 152 CS*U075L44 0.75 ----- ----- ----- ----- ----- 4280 3450 2710 2380 2070 1570 5.1 1 3/8 5/8 157 CS*U100L44 1.0 ----- ----- ----- ----- ----- 5670 4580 3580 3130 2700 1940 5.1 1 3/8 5/8 180 CS*U150L44 1.5 ----- ----- ----- ----- ----- 9870 7670 5680 4760 3900 2330 8.6 2 3/8 7/8 195 CS*U200L44 2.0 ----- ----- ----- ----- ----- 14260 11240 8620 7390 6210 4020 8.6 3 3/8 7/8 243 CS*U300L44 3.0 ----- ----- ----- ----- ----- 17230 13960 10640 9070 7570 4790 13.7 3 1/2 1-1/8 255 2 2 CS*U050H22 0.5 7760 6330 5650 4980 3890 2850 ----- ----- ----- ----- ----- 6.0 1 3/8 5/8 170 CS*U075H22 0.75 9280 7690 6930 5990 5030 4010 ----- ----- ----- ----- ----- 6.0 1 3/8 5/8 175 CS*U125H22 1.0 13820 11370 10290 9150 7190 5380 ----- ----- ----- ----- ----- 6.0 1 3/8 5/8 180 CS*U150H22 1.5 17410 14220 12670 11230 8600 6290 ----- ----- ----- ----- ----- 10.0 2 3/8 7/8 210 CS*U200H22 2.0 22050 17980 16160 14340 11030 7940 ----- ----- ----- ----- ----- 10.0 2 3/8 7/8 223 CS*U250H22 2.5 28820 23320 20790 18370 13970 10500 ----- ----- ----- ----- ----- 16.0 2 1/2 7/8 245 CS*U300H22 3.0 35530 29150 26180 23430 18150 13200 ----- ----- ----- ----- ----- 16.0 2 1/2 7/8 260 CS*U400H22 4.0 45540 36850 32670 28820 21890 15950 ----- ----- ----- ----- ----- 28.2 3 1/2 7/8 348 CS*U500H22 5.0 57010 46770 41970 37500 29330 22350 ----- ----- ----- ----- ----- 28.2 3 1/2 7/8 348 Scroll Models 4 0 4 A 2 2 MODEL # HP +35 +30 +25 +20 +10 0-10 -20-25 -30-40 REC'R FIG. LIQ. SUC. SHIP WT. CS*O200M44 2.00 21930 20350 18820 17360 14630 12160 ----- ----- ----- ----- ----- 13.7 2 1/2 7/8 215 CS*O250M44 2.50 27080 25050 23160 21320 17900 14840 ----- ----- ----- ----- ----- 13.7 2 1/2 1-1/8 230 CS*O300M44 3.00 31110 29050 26940 24860 20850 17090 ----- ----- ----- ----- ----- 13.7 2 1/2 1-1/8 305 CS*O301M44 3.00 37190 34790 32330 29540 25190 20770 ----- ----- ----- ----- ----- 13.7 2 1/2 1-1/8 325 CS*O400M44 4.00 44000 40480 37640 34630 29310 24800 ----- ----- ----- ----- ----- 24.3 3 1/2 1-1/8 352 CS*O600M44 6.00 50400 47800 44200 41100 34500 28800 ----- ----- ----- ----- ----- 24.3 3 1/2 1-1/8 383 CS*O650M44 6.50 60240 56520 52860 49060 42050 34840 ----- ----- ----- ----- ----- 24.3 3 1/2 1-1/8 405 CS*O200L44 2.00 ----- ----- ----- ----- ----- 11330 9400 7670 6870 6110 4390 13.7 2 1/2 7/8 230 CS*O250L44 2.50 ----- ----- ----- ----- ----- 13800 12100 10060 8980 7720 5800 13.7 2 1/2 7/8 240 CS*O300L44 3.00 ----- ----- ----- ----- ----- 15960 13380 11360 9680 8670 6520 13.7 2 1/2 1-1/8 245 CS*O301L44 3.00 ----- ----- ----- ----- ----- 18760 15530 12580 11250 10160 8110 13.7 2 1/2 1-1/8 255 CS*O400L44 4.00 ----- ----- ----- ----- ----- 24090 19800 15940 14080 12430 8600 24.3 3 1/2 1-1/8 352 CS*O500L44 5.00 ----- ----- ----- ----- ----- 28490 23650 19250 17270 13200 11990 24.3 3 1/2 1-1/8 367 CS*O600L44 6.00 ----- ----- ----- ----- ----- 33400 27400 22100 19800 17600 13600 24.3 3 1/2 1-1/8 383 CS*O200M22 2.00 21020 19890 18270 16900 13960 ----- ----- ----- ----- ----- ----- 13.7 2 1/2 7/8 215 CS*O250M22 2.50 25340 23400 21310 19940 16370 ----- ----- ----- ----- ----- ----- 13.7 2 1/2 1-1/8 230 CS*O300M22 3.00 30440 28170 25840 23470 19330 ----- ----- ----- ----- ----- ----- 13.7 2 1/2 1-1/8 305 CS*O301M22 3.00 38180 34720 31890 28310 22730 ----- ----- ----- ----- ----- ----- 13.7 2 1/2 1-1/8 325 CS*O400M22 4.00 43320 39910 37460 33680 27750 ----- ----- ----- ----- ----- ----- 28.2 3 1/2 1-1/8 352 CS*O600M22 6.00 52390 48370 43930 41010 34010 ----- ----- ----- ----- ----- ----- 28.2 3 1/2 1-1/8 383 CS*O650M22 6.50 63120 57830 51850 48280 41130 ----- ----- ----- ----- ----- ----- 28.2 3 1/2 1-1/8 405 NOTE: For 90 F ambient multiply capacity by 1.03. Reduce capicity by 3% for each 5 increase in ambient temperature. Consult factory for capacities above 110 F Amb. * See rear cover for dimensional drawings 4

Electrical Data Hermetic Models MiniLine COMP. AMPS @ 230/1/60 AMPS @ 208/230/3/60 AMPS @460/3/60 MODEL MODEL COMPRESSOR COND TOTAL MCA COMPRESSOR COND TOTAL MCA COMPRESSOR COND TOTAL MCA NUMBER NUMBER RLA LRA FLA UNIT RLA LRA FLA UNIT RLA LRA FLA UNIT CS*U050M44 AKA9438Z 4.3 31.0 1.0 6.3 15.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U075M44 AKA9462Z 6.8 34.0 1.0 8.8 15.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U101M44 AJA7494Z 8.9 54.0 2.0 14.0 17.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U150M44 AWA9512Z 8.9 60.0 2.0 13.9 17.0 5.5 50.0 2.0 10.5 15.0 ----- ----- ----- ----- ----- CS*U200M44 AVA9519Z 14.5 95.0 2.0 19.0 23.0 9.4 73.4 2.0 13.4 16.0 ----- ----- ----- ----- ----- CS*U300M44 AVA9522Z 17.0 108.0 2.0 21.0 26.0 10.3 74.0 2.0 14.4 19.0 ----- ----- ----- ----- ----- CS*U400M44 AVA9528Z 20.0 132.0 3.2 28.1 35.0 13.3 110.0 3.2 19.5 24.0 6.6 55.0 2.1 9.7 15.0 CS*U500M44 AGA9530Z 25.0 165.0 3.2 34.9 43.0 16.0 126.0 3.2 24.9 31.0 7.5 62.0 2.1 11.2 15.0 CS*U050L44 AKA9438Z 4.3 31.0 1.0 7.4 15.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U075L44 AJB2433Z 4.7 37.0 1.0 6.7 15.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U100L44 AJB2444Z 6.5 55.0 1.0 8.5 15.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U150L44 AWA2460Z 8.2 86.0 2.0 14.4 18.0 5.6 63.4 2.0 10.0 15.0 ----- ----- ----- ----- ----- CS*U200L44 AVA2490Z 11.4 106.6 2.0 19.7 24.0 7.4 65.1 2.0 13.2 16.0 ----- ----- ----- ----- ----- CS*U300L44 AVA2512Z 16.9 120.3 2.0 23.5 28.0 9.3 65.1 2.0 15.3 18.0 4.6 38.3 1.0 8.1 15.0 CS*U050H22 AKA9442E 4.0 31.0 1.0 7.9 15.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U075H22 AKA9455E 4.9 31.0 1.0 9.1 15.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U125H22 AJA9484E 6.9 54.0 1.0 9.0 15.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U150H22 AWG5520E 9.3 52.0 2.0 12.0 15.0 5.8 51.0 2.0 9.0 15.0 ----- ----- ----- ----- ----- CS*U200H22 AWG5524E 11.0 60.0 2.0 16.5 20.0 6.7 50.0 2.0 10.5 15.0 ----- ----- ----- ----- ----- CS*U250H22 AVA5532E 14.5 78.0 2.0 19.0 23.0 8.9 59.5 2.0 13.6 17.0 4.4 32.8 1.0 6.2 15.0 CS*U300H22 AVA5542E 19.7 108.0 2.0 22.4 28.0 12.0 74.0 2.0 16.1 20.0 6.0 37.0 1.0 7.4 15.0 CS*U400H22 AVD5548E 19.2 110.0 3.2 23.4 29.0 12.3 105.0 3.2 16.5 20.0 6.2 52.2 2.1 8.8 15.0 CS*U500H22 AVB5558E 24.8 141.0 3.2 33.2 41.0 15.7 110.0 3.2 22.2 27.0 7.8 55.0 2.1 11.7 15.0 Scroll Models CS*O200M44 ZS15K4E 13.6 55.0 2.0 17.5 20.0 9.3 55.0 2.0 12.3 15.0 4.3 27.0 1.0 5.8 15.0 CS*O250M44 ZS19K4E 16.4 73.0 2.0 20.3 25.0 9.7 63.0 2.0 12.7 15.0 5.0 31.0 1.0 6.5 15.0 CS*O300M44 ZS21K4E 16.4 88.0 2.0 20.6 25.0 11.1 77.0 2.0 14.1 17.0 5.7 39.0 1.0 7.2 15.0 CS*O301M44 ZS26K4E 20.7 109.0 2.0 24.9 30.0 13.6 88.0 2.0 16.6 20.0 7.1 44.0 1.0 8.6 15.0 CS*O400M44 ZS30K4E 26.8 129.0 3.2 31.0 38.0 15.0 99.0 3.2 19.2 23.0 8.2 49.5 2.1 10.8 15.0 CS*O600M44 ZS38K4E 31.8 169.0 3.2 36.0 36.0 21.4 123.0 3.2 25.6 31.0 9.6 62.0 2.1 12.2 15.0 CS*O650M44 ZS45K4E ----- ----- ----- ----- ----- 23.9 156.0 3.2 28.1 34.0 9.3 70.0 2.1 11.9 15.0 CS*O200L44 ZF06K4E 13.6 55.0 2.0 16.6 20.0 9.3 55.0 2.0 12.3 16.0 4.3 27.0 1.0 5.8 15.0 CS*O250L44 ZF08K4E 16.4 73.0 2.0 19.4 25.0 9.7 63.0 2.0 12.7 16.0 5.0 31.0 1.0 6.5 15.0 CS*O300L44 ZF09K4E 16.4 88.0 2.0 19.4 25.0 11.1 77.0 2.0 14.1 17.0 5.7 39.0 1.0 7.2 15.0 CS*O301L44 ZF11K4E 20.7 109.0 2.0 23.7 30.0 13.6 88.0 2.0 16.6 20.0 7.1 44.0 1.0 8.6 15.0 CS*O400L44 ZF13K4E 26.8 129.0 3.2 31.0 38.0 15.0 99.0 3.2 19.2 23.0 8.2 57.0 2.1 10.8 19.0 CS*O500L44 ZF15K4E 31.5 169.0 3.2 35.7 44.0 21.4 123.0 3.2 25.6 31.0 9.6 62.0 2.1 12.2 23.0 CS*O600L44 ZF18K4E ----- ----- ----- ----- ----- 23.9 156.0 3.2 28.1 34.0 9.3 70.0 2.1 11.9 23.0 CS*O200M22 ZS15K4E 13.6 55.0 2.0 17.5 20.0 9.3 55.0 2.0 12.3 15.0 4.3 27.0 1.0 5.8 15.0 CS*O250M22 ZS19K4E 16.4 73.0 2.0 20.3 25.0 9.7 63.0 2.0 12.7 15.0 5.0 31.0 1.0 6.5 15.0 CS*O300M22 ZS21K4E 16.4 88.0 2.0 20.6 25.0 11.1 77.0 2.0 14.1 17.0 5.7 39.0 1.0 7.2 15.0 CS*O301M22 ZS26K4E 20.7 109.0 2.0 24.9 30.0 13.6 88.0 2.0 16.6 20.0 7.1 44.0 1.0 8.6 15.0 CS*O400M22 ZS30K4E 26.8 129.0 3.2 31.0 38.0 15.0 99.0 3.2 19.2 23.0 8.2 49.5 2.1 10.8 15.0 CS*O600M22 ZS38K4E 31.8 169.0 3.2 36.0 36.0 21.4 123.0 3.2 25.6 31.0 9.6 62.0 2.1 12.2 15.0 CS*O650M22 ZS45K4E ----- ----- ----- ----- ----- 23.9 156.0 3.2 28.1 34.0 9.3 70.0 2.1 11.9 15.0 Total Unit Amps includes approximate allowance for control circuit as follows: 1A @ 208/230V; 0.5A @ 460V MCA (Minimum Branch Circuit Ampacity) does not include evaporator(s) electrical requirements (evaporator fan motor amps, defrost heater amps). Contact factory for more details. 5

Performance Data Semi-Hermetic Models 4 0 4 A MODEL NUMBER NOM. H.P. CAPACITY (BTUH) AT 95 F AMBIENT Physical Data REC'R @ 90% CONN. (ODS. IN.) APPROX SHIP WT (LBS) SUCTION TEMPERATURE FIG +40 +35 +25 +20 +10 0-10 -20-25 -35-40 (LBS) LIQ. SUC. CS*C300M44 3.0 ---- ---- 26420 23960 19330 15130 ---- ---- ---- ---- ---- 13.7 2 1/2 7/8 330 CS*C400M44 5.0 ---- ---- 42130 37930 29990 22750 ---- ---- ---- ---- ---- 24.3 3 1/2 7/8 455 CS*C500M44 5.0 ---- ---- 55620 50040 39720 30560 ---- ---- ---- ---- ---- 24.3 3 1/2 1-1/8 475 CS*C600M44 6.5 ---- ---- 63150 57000 45580 35340 ---- ---- ---- ---- ---- 24.3 3 1/2 1-1/8 490 CS*C200L44 2.0 ---- ---- ---- ---- ---- 17320 13840 10770 9400 6990 5930 13.7 2 1/2 7/8 340 CS*C300L44 3.0 ---- ---- ---- ---- ---- 25750 19630 14440 12180 8320 6690 24.3 3 1/2 1-1/8 470 CS*C400L44 4.0 ---- ---- ---- ---- ---- 33470 26470 20290 17510 12560 10380 24.3 3 1/2 1-1/8 475 CS*C500L44 5.0 ---- ---- ---- ---- ---- 38890 31300 24520 21430 15850 13350 24.3 3 1/2 1-3/8 490 CS*C600L44 6.5 ---- ---- ---- ---- ---- 45520 36120 27840 24120 17500 14590 24.3 3 1/2 1-3/8 500 2 2 CS*C300M22 3.0 ---- ---- 25350 22740 17980 13810 ---- ---- ---- ---- ---- 16.0 2 1/2 7/8 330 CS*C400M22 5.0 57730 52140 41930 37300 28960 21790 ---- ---- ---- ---- ---- 28.2 3 1/2 7/8 455 CS*C500M22 5.0 70520 63920 51850 46370 36510 28050 ---- ---- ---- ---- ---- 28.2 3 1/2 1-1/8 475 CS*C600M22 6.5 ---- 72850 59240 53000 41670 31800 ---- ---- ---- ---- ---- 28.2 3 1/2 1-1/8 490 CS*C200L22 2.0 ---- ---- ---- ---- ---- 15930 12360 9230 7760 4930 ---- 10.0 2 1/2 7/8 340 CS*C300L22 3.0 ---- ---- ---- ---- ---- 25140 19610 14830 12620 8370 ---- 28.2 3 1/2 1-1/8 470 CS*C400L22 4.0 ---- ---- ---- ---- ---- 30010 23620 18070 15510 10580 ---- 28.2 3 1/2 1-1/8 475 CS*C500L22 5.0 ---- ---- ---- ---- ---- 34160 27100 20980 18150 12710 ---- 28.2 3 1/2 1-3/8 490 CS*C600L22 6.5 ---- ---- ---- ---- ---- 41100 32420 25090 21760 15400 ---- 28.2 3 1/2 1-3/8 500 NOTE: For 90 F ambient multiply capacity by 1.03. Reduce capicity by 3% for each 5 increase in ambient temperature. Consult factory for capacities above 110 F Amb. * See rear cover for dimensional drawings Also available from Carrier: Model CWA / CWE For Walk - In Coolers & Freezers 3,900 to 39,000 BTUH Low Profile Unit Coolers See Publication number C - 200 for details Low Air Velocity Unit Coolers Model LWA / LWE For Walk - In Coolers 6,700 to 37,000 BTUH See Publication number C - 240 for details 6

Electrical Data Semi-Hermetic Models MODEL NUMBER COMP. MODEL NUMBER AMPS @ 230/1/60 AMPS @ 208-230/3/60 AMPS @ 460/3/60 COMPRESSOR COND TOTA COMPRESSOR COND TOTA COMPRESSOR CON MCA MCA RLA LRA FLA L RLA LRA FLA L RLA LRA D CS*C300M44 06DM808 20.0 110.0 2.0 23.0 28.0 11.2 71.0 2.0 14.2 17.0 5.6 35.5 1.0 7.1 9.0 CS*C400M44 06DM313 28.6 150.0 3.2 32.8 40.0 17.3 100.0 3.2 21.5 26.0 8.6 50.0 2.1 11.2 14.0 CS*C500M44 06DM316 28.6 150.0 3.2 32.8 40.0 17.3 100.0 3.2 21.5 26.0 8.6 50.0 2.1 11.2 14.0 CS*C600M44 06DA818 ---- ---- ---- ---- ---- 28.2 160.0 3.2 32.4 40.0 14.1 80.0 2.1 16.7 21.0 CS*C200L44 06DR109 17.1 110.0 2.0 20.1 25.0 7.6 53.3 2.0 10.6 13.0 3.5 26.3 1.0 5.0 6.0 CS*C300L44 06DR013 23.3 100.0 3.2 27.5 34.0 11.2 71.0 3.2 15.4 19.0 5.6 35.5 2.1 8.2 10.0 CS*C400L44 06DR316 28.6 150.0 3.2 32.8 40.0 17.3 100.0 3.2 21.5 26.0 8.6 50.0 2.1 11.2 14.0 CS*C500L44 06DR718 28.6 150.0 3.2 32.8 40.0 17.3 100.0 3.2 21.5 26.0 8.6 50.0 2.1 11.2 14.0 CS*C600L44 06DR820 ---- ---- ---- ---- ---- 28.2 160.0 3.2 32.4 40.0 14.1 80.0 2.1 16.7 21.0 CS*C300M22 06DM808 20.0 110.0 2.0 23.0 28.0 11.2 71.0 2.0 14.2 17.0 5.6 35.5 1.0 7.1 9.0 CS*C400M22 06DM313 28.6 150.0 3.2 32.8 40.0 17.3 100.0 3.2 21.5 26.0 8.6 50.0 2.1 11.2 14.0 CS*C500M22 06DM316 28.6 150.0 3.2 32.8 40.0 17.3 100.0 3.2 21.5 26.0 8.6 50.0 2.1 11.2 14.0 CS*C600M22 06DA818 ---- ---- ---- ---- ---- 28.2 160.0 3.2 32.4 40.0 14.1 80.0 2.1 16.7 21.0 CS*C200L22 06DR109 17.1 110.0 2.0 20.1 25.0 7.6 53.3 2.0 10.6 13.0 3.5 26.3 1.0 5.0 6.0 CS*C300L22 06DR013 23.3 100.0 3.2 27.5 34.0 11.2 71.0 3.2 15.4 19.0 5.6 35.5 2.1 8.2 10.0 CS*C400L22 06DR316 28.6 150.0 3.2 32.8 40.0 17.3 100.0 3.2 21.5 26.0 8.6 50.0 2.1 11.2 14.0 CS*C500L22 06DR718 28.6 150.0 3.2 32.8 40.0 17.3 100.0 3.2 21.5 26.0 8.6 50.0 2.1 11.2 14.0 CS*C600L22 06DR820 ---- ---- ---- ---- ---- 28.2 160.0 3.2 32.4 40.0 14.1 80.0 2.1 16.7 21.0 Total Unit Amps includes approximate allowance for control circuit as follows: 1A - 208/230V; 0.5A - 460V. MCA Minimum Circuit Ampacity does not include evaporator(s) electrical requirements. (Evaporator fan motor amps, defrost heater amps) Contact factory for specific details. MiniLine TOTA L MCA Dual Air Discharge Unit Coolers Also available from Carrier: Model DWA / DWE For Walk - In Coolers & Freezers 3,900 to 39,000 BTUH See Publication number C - 230 for details Model LWA / LWE For Refrigerated Warehouses 16,400 to 273,000 BTUH Large Profile Unit Coolers See Publication number C - 220 for details 7

MiniLine Physical Dimensions - All Models Figure 1 28 1 4 26 1 4 Suction Liquid 17 1 4 Electrical Access Electrical Connections * All dimensions are in inches All mounting holes are 3/8" 21 c/c 27 c/c 27 3 4 Figure 2 28 1 4 38 1 4 Suction Liquid *See Note Electrical Access Electrical Connections All dimensions are in inches All mounting holes are 3/8" 21 c/c 39 c/c 39 3 4 *17 1 4" high for 1 2 to 2 HP models. Uses 2 piece grill as shown. 20 1 4" high for 2 1 2 and 3 HP and all Scroll models. Uses 1 piece grill. Figure 3 33 42 1 4 32 1 4 Suction Liquid Electrical Access Right Side Electrical Connections 29 c/c 43 c/c 43 3 4 Commercial Refrigeration A member of the United Technologies Corporation family. Stock Symbol - UTX Manufacture reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 221 South Berry St., Brea, CA 92821 Tel: (714) 529-9571 Fax: (714) 529-7203

Commercial Refrigeration MaxLine Air Cooled Condensing Units 20 to 80 HP Literature No. - C320 December, 2006 MEA Medium and Low Temperature Units Carlyle semi-hermetic Compressors

Our condensing units are designed with efficient service access in mind. Extracting just a very few screws allows complete removal of the compressor housing top panel, side panel and corner post. This gives the mechanic quick, unrestricted access to the compressor, all controls and components located within the compressor compartment. Or, only a single panel can be removed, depending upon the requirements of the service call. The large control panel has abundant space for the controls you choose. They are intelligently arranged and laid out in a logical fashion which is easy to understand and work with. Each control and wire is clearly marked with a name or number as shown on the wiring diagram which is conveniently affixed to the control panel door. CONTROL VOLTAGE TRANSFORMER CONTROL CIRCUIT FUSES DEFROST CLOCK* ENERGY SAVER PRESSURE CONTROL* COMPRESSOR CONTACTOR POWER TERMINAL BLOCK EVAP FAN MOTOR CONTACTOR* BLOCK OUT RELAY* EVAPORATOR DEFROST CONTACTORS* EVAPORATOR SEQUENCING RELAYS* NON-FUSED DISCONNECT SWITCH* DOOR INTERLOCK* EVAPORATOR FAN AND HEATER SUB-CIRCUIT FUSING* CONDENSER FAN MOTOR CAPACITORS 2

MaxLine MODEL NUMBER NOMENCLATURE CL L C 20 H 22 CL TYPE LARGE UNIT STYLE OF UNIT L = Outdoor unit w/ Flooded controls S = Outdoor unit w/ Floating Head pressure controls C = Outdoor unit w/ no head pressure controls COMPRESSOR STYLE C = Carlyle semi-hermetic REFRIGERANT TYPE 22 = R-22 44 = R-404A 57 = R-507 OPERATING RANGE H = High Temp (+10 F to +45 F Suction Temp) M = High/Medium Temp (-10 F to +45 F Suction Temp) L = Low Temp (-40 F to 0 F Suction Temp) NOMINAL HORSEPOWER ELECTRICAL COMPONENTS CONDENSER PIPING COMPONENTS RECEIVER HOUSING LOW AMBIENT CONTROLS Raised galvanized steel base All ambient energy saver Pressure fan cycling control FEATURES AT A GLANCE Crankcase heater Oil failure control - as required High-Low pressure control - manual(high)/automatic(low)rest Compressor contactor Control circuit fuses - standard 230/1 Power terminal block Copper tubes with Aluminum fins Sub-cooling circuit Fan motor - PSC overload protection Fan blade - individually balanced Fan guard - Heavy duty resilient wire basket Suction line filter (replaceable core - some models) Suction line vibration eliminator Replaceable core liquid line filter/drier Sight glass/moisture indicator Discharge line vibration eliminator High pressure control hoses Pressure relief device Inlet and outlet isolation valves Mill finish galvanized steel with removable access panels Flooded condenser UL/cUL listed - all models TESTING Leak detection, Dielectric & Run test Dry nitrogen holding charge OPTIONS: 4 year extended compressor warranty Air defrost time clock Compressor unloading Copper or coated condenser fins Crankcase pressure regulator Electric defrost components Evaporator sub circuit fusing Fused disconnect Heated and insulated receiver - not UL MODEL CLC CLL CLS N/A N/A N/A Hot Gas Defrost components Liquid line solenoid valve Oil separator Oversized receiver Phase loss monitor Electronic oil safety control Spring loaded relief valve Stainless steel hoses Suction line accumulator N/A N/A 3

ENERGY-SAVER SYSTEMS The initial cost of quality refrigeration equipment is a substantial investment. But the costs of installation and operation are also formidable. Rising to the challenge, our engineers have designed the ENERGY-SAVER system to meet the highest standards of performance and reliability while effectively addressing the problem of these profit draining costs. REDUCED INSTALLATION COSTS The installation of a refrigeration system using ENERGY-SAVER requires a smaller refrigerant charge than equipment which utilizes other types of low ambient controls. As the more expensive zero ozone depleting, refrigerants become the refrigerants of choice, the reduced charge requirements provided by ENERGY-SAVER affords substantial and immediate cost saving benefits. ENERGY-SAVER saves money during hot weather. The most expensive part of a refrigeration system is the cost of energy to operate the compressor. Day and night, year after year, the expense of purchasing electricity to run your equipment is unrelenting. These dollars come right from your bottom line. The sub cooling loop provided in the condenser of an ENERGY-SAVER condensing unit increases system efficiency 1/2% for each degree of sub cooling provided, thereby making the compressor s job easier. ENERGY-SAVER S efficiency saves you money during summer operation and even more during the winter months. REDUCED OPERATING COSTS A typical installation is designed to ensure that equipment performance will furnish adequate cooling on the hottest, most demanding days. The ENERGY-SAVER system is designed to meet this requirement but also be flexible enough to take advantage of cost saving opportunities during reduced ambient conditions. With ENERGY-SAVER, as the outside air temperature decreases, head pressures are allowed to drop. These conditions result in increased efficiency, requiring less energy and saving substantial amounts of electricity and putting money back into your pocket! 4

MaxLine ENERGY-SAVER ENERGY SAVINGS CALCULATIONS To estimate your average monthly savings: 1) Select an ENERGY-SAVER system that meets your refrigeration requirements. 2) Determine the Average Annual Outdoor Air Temperature from the table below. 3) Using the Projected Monthly Savings graph, locate the system nominal horsepower at the bottom of the graph (the nominal system horsepower can be derived from the model number nomenclature). 4) Go straight up to the appropriate Average Annual Outdoor Air Temperature curve, and then go horizontally to the left to determine your Estimated Monthly Average Savings. 5) To calculate your Estimated Monthly Saving for an energy cost other than $0.10 KWH, divide the Estimated Monthly Savings by 0.10 and multiply by your local electric utility rate. 6) To determine your Estimated Yearly Savings, multiple the Estimated Monthly Savings number by 12. AVERAGE ANNUAL OUTDOOR AIR TEMPERATURE STATE & ANNUAL STATE & ANNUAL STATE & ANNUAL STATE & ANNUAL STATION AVG. F STATION AVG. F STATION AVG. F STATION AVG. F AL Mobile 70 IA Des Moines 50 NM Albuquerque 60 VT Burlington 45 AK Juneau 40 KS Wichita 55 NY Buffalo 45 VA Richmond 60 AZ Phoenix 70 KY Louisville 55 New York 55 WA Seattle 50 AR Little Rock 60 LA New Orleans 70 NC Charlotte 60 WV Charleston 55 CA Los Angeles 60 ME Portland 45 ND Bismarck 45 WI Milwaukee 45 San Francisco 55 MD Baltimore 55 OH Cleveland 50 WY Cheyenne 45 CO Denver 50 MA Boston 50 Columbus 50 CT Hartford 50 MI Detroit 50 OK Oklahoma City 60 CANADA DE Wilmington 55 MN Sault St. Marie 40 OR Portland 55 ALB Calgary 40 D.C. Washington 55 Minneapolis 45 PA Philadelphia 50 B.C. Vancouver 50 FL Jacksonville 70 MS Jackson 65 RI Providence 50 MAN Winnipeg 35 Miami 75 MO St. Louis 55 SC Columbia 65 N.B. St. John 45 GA Atlanta 60 MT Great Falls 45 SD Sioux Falls 45 N.F. St. John's 40 HI Honolulu 75 NE Omaha 50 TN Nashville 60 N.S. Halifax 45 ID Boise 50 NV Reno 50 TX Dallas 65 ONT Toronto 45 IL Chicago 50 NH Concord 45 El Paso 65 QUE Montreal 45 IN Indianapolis 50 NJ Atlantic City 55 UT Salt Lake City 50 YUK Dawson 25 AVERAGE MONTHLY SAVINGS ($) 800 700 600 500 400 300 200 100 0 ENERGY-SAVER PROJECTED MONTHLY SAVINGS @ $0.10/ KWH 20 25 30 35 40 45 50 55 60 65 70 75 80 SYSTEM HORSEPOWER 45 o F 55 o F 65 o F 75 o F AVERAGE ANNUAL TEMPERATURE 5

BTUH CAPACITIES R-22 MEDIUM TEMP - SINGLE COMPRESSOR 90 AMBIENT 95 AMBIENT 100 AMBIENT 110 AMBIENT SUCTION TEMPERATURE F CLC/CLL/CLS +45 +35 +25 +20 +10 0 20H22 216800 177000 142800 127500 100700 78300 25H22 287500 235800 190900 170800 135100 104900 30H22 375900 305200 244100 217000 169300 129600 35H22 414300 338700 272700 243100 190200 145100 40H22 536500 440000 356400 319200 253200 197800 CLC/CLL/CLS +45 +35 +25 +20 +10 0 20H22 209500 170900 137700 122900 97000 75300 25H22 277300 227300 183700 164300 129700 100500 30H22 362100 293500 234300 208200 162000 123700 35H22 400700 326900 262500 233700 182100 138100 40H22 519000 425300 344100 308000 244000 190200 CLC/CLL/CLS +45 +35 +25 +20 +10 0 20H22 202300 164900 132700 118400 93200 72200 25H22 267300 218800 176600 157800 124400 96100 30H22 348400 281900 224800 199500 154900 117900 35H22 387000 315100 252300 224200 173900 131000 40H22 501700 410700 332000 296900 234900 182800 CLC/CLL/CLS +45 +35 +25 +20 +10 0 20H22 188100 153000 122800 109500 86000 66300 25H22 247300 201900 162600 145000 113800 87400 30H22 321600 259400 206100 182500 141100 106600 35H22 359600 291400 231900 205200 157500 116800 40H22 467500 381900 308000 275100 217000 168200 6

MaxLine BTUH CAPACITIES R-22 MEDIUM TEMP - Parallel / Dual 90 AMBIENT 95 AMBIENT 100 AMBIENT 110 AMBIENT SUCTION TEMPERATURE F CLC/CLL/CLS +45 +35 +25 +20 +10 0 17H22 / 18H22 278800 224400 177800 157300 121400 91600 21H22 / 23H22 331100 267900 214000 190300 148700 114300 31H22 / 32H22 448500 364500 292600 260900 205400 159200 51H22 / 52H22 597900 488000 393200 351100 276700 214100 61H22 / 62H22 791000 637800 507100 449500 348900 265800 71H22 / 72H22 855100 697100 559900 498600 389400 296700 81H22 / 82H22 1114900 909700 733400 655300 517900 403200 CLC/CLL/CLS +45 +35 +25 +20 +10 0 17H22 / 18H22 268400 215600 170500 150600 115800 87000 21H22 / 23H22 319500 258200 206000 183000 142700 109500 31H22 / 32H22 433500 351900 282300 251500 197700 153000 51H22 / 52H22 576900 470300 378400 337600 265500 205000 61H22 / 62H22 761900 613400 486800 431100 333800 253600 71H22 / 72H22 827900 673500 539500 479700 373100 282400 81H22 / 82H22 1079200 879600 708300 632600 499100 387800 CLC/CLL/CLS +45 +35 +25 +20 +10 0 17H22 / 18H22 258200 207000 163300 144000 110400 82500 21H22 / 23H22 308000 248600 198000 175800 136900 104700 31H22 / 32H22 418700 339600 272000 242300 190100 146800 51H22 / 52H22 556200 452900 363900 324400 254600 196000 61H22 / 62H22 733300 589400 466900 413100 319100 241600 71H22 / 72H22 800600 649800 519100 460600 356600 268100 81H22 / 82H22 1043700 849800 683500 610000 480600 372700 CLC/CLL/CLS +45 +35 +25 +20 +10 0 17H22 / 18H22 238000 190000 149100 131100 99700 73800 21H22 / 23H22 285600 229900 182500 161800 125500 95500 31H22 / 32H22 389600 315300 251900 224100 175300 134800 51H22 / 52H22 515400 418500 335300 298400 233200 178500 61H22 / 62H22 677200 542400 428000 377900 290500 218500 71H22 / 72H22 745600 602200 477800 422300 323400 239400 81H22 / 82H22 973700 791000 634600 565600 444200 343100 7

BTUH CAPACITIES R-22 LOW TEMPERATURE SUCTION TEMPERATURE F 90 AMBIENT 95 AMBIENT 100 AMBIENT 110 AMBIENT CLC/CLL/CLS 0-10 -20-25 -30-35 25L22 153400 119400 90400 77200 64500 52300 30L22 195300 150600 112900 96000 79800 64000 44L22 / 46L22 283000 215400 158200 132400 107600 83700 54L22 / 56L22 312400 243100 184100 157200 131600 106600 61L22 / 62L22 402200 309500 231700 196800 163500 131300 CLC/CLL/CLS 0-10 -20-25 -30-35 25L22 148500 115100 86600 73600 61100 48900 30L22 188400 144700 107900 91300 75400 60000 44L22 / 46L22 272600 206300 150100 124600 100200 76500 54L22 / 56L22 303000 234800 176600 150200 124800 100000 61L22 / 62L22 388500 297800 221700 187400 154800 123100 CLC/CLL/CLS 0-10 -20-25 -30-35 25L22 143600 110800 82700 69900 57600 45500 30L22 181500 138800 102800 86600 71100 55900 44L22 / 46L22 262100 197000 141700 116700 92700 69300 54L22 / 56L22 293300 226300 169000 142800 117700 93100 61L22 / 62L22 374800 285900 211500 178000 146000 114800 CLC/CLL/CLS 0-10 -20-25 -30-35 25L22 133500 101900 74700 62300 50200 38400 30L22 167500 126900 92600 77100 62200 47600 44L22 / 46L22 240600 177900 124700 100400 77100 54300 54L22 / 56L22 273500 208700 153100 127500 102900 78700 61L22 / 62L22 346900 262000 190800 158700 128000 98000 8

MaxLine BTUH CAPACITIES R-404A / R-507 - LOW TEMPERATURE 90 AMBIENT SUCTION TEMPERATURE F CLC/CLL/CLS 0-10 -20-25 -30-40 25L44 182900 143200 108700 93400 79200 54100 30L44 218700 174600 136200 119000 103000 74800 44L44 / 46L44 333100 258700 195800 168400 143600 100900 54L44 / 56L44 381900 297100 224400 192300 162800 111000 61L44 / 62L44 462100 366000 283500 247000 213300 154200 95 AMBIENT CLC/CLL/CLS 0-10 -20-25 -30-40 25L44 174600 136300 103100 88200 74500 50200 30L44 208300 166000 129100 112500 97200 69800 44L44 / 46L44 316000 244600 184500 158300 134500 93500 54L44 / 56L44 365200 283300 213100 182000 153400 103100 61L44 / 62L44 440900 348500 269000 233800 201400 144100 100 AMBIENT CLC/CLL/CLS 0-10 -20-25 -30-40 25L44 166200 129400 97400 83100 69800 46300 30L44 197900 157400 122000 106100 91300 64900 44L44 / 46L44 298900 230700 173200 148200 125400 86200 54L44 / 56L44 348300 269400 201600 171500 143900 95100 61L44 / 62L44 419600 330800 254500 220600 189400 134100 110 AMBIENT CLC/CLL/CLS 0-10 -20-25 -30-40 25L44 149300 115400 85900 72700 60400 38500 30L44 177300 140200 107800 93200 79600 55200 44L44 / 46L44 265300 203300 151200 128500 107900 72200 54L44 / 56L44 314000 241000 178200 150400 124700 79100 61L44 / 62L44 376800 295400 225400 194200 165400 114100 9

BTUH CAPACITIES R-404A / R-507 - MEDIUM TEMP Single Compressor 90 AMBIENT 95 AMBIENT 100 AMBIENT 110 AMBIENT SUCTION TEMPERATURE F CLC/CLL/CLS +45 +35 +25 +20 +10 0 20M44 229000 190200 155900 140400 112400 88200 25M44 307700 253600 206000 184600 146200 113400 30M44 387300 321400 261900 234600 184600 140500 35M44 452800 374300 304700 273200 216400 167600 40M44 537400 463400 398400 368900 315600 268600 CLC/CLL/CLS +45 +35 +25 +20 +10 0 20M44 219200 182000 149100 134100 107300 84000 25M44 293300 241600 196100 175600 138900 107500 30M44 368800 305700 248800 222600 174500 131900 35M44 431100 356300 289900 259800 205700 158900 40M44 511000 440400 378400 350300 299300 254200 CLC/CLL/CLS +45 +35 +25 +20 +10 0 20M44 209100 173600 142100 127800 102100 79800 25M44 278700 229500 186200 166700 131700 101700 30M44 350300 290000 235600 210400 164300 123300 35M44 409500 338300 275200 246600 194900 150200 40M44 483600 416700 357600 330900 282200 239000 CLC/CLL/CLS +45 +35 +25 +20 +10 0 20M44 188100 156000 127500 114600 91300 71200 25M44 249000 204700 165800 148300 116900 90000 30M44 313000 258300 208800 185900 143700 106000 35M44 366300 302400 245700 220000 173500 133000 40M44 427000 366900 313700 289600 245600 206300 10

MaxLine BTUH CAPACITIES R-404A / R-507 - MEDIUM TEMP Parallel / Dual 90 AMBIENT 95 AMBIENT 100 AMBIENT 110 AMBIENT SUCTION TEMPERATURE F CLC/CLL/CLS +45 +35 +25 +20 +10 0 17M44 / 18M44 307700 250800 201200 179000 139300 105500 21M44 / 23M44 363100 296600 239000 213400 168100 129900 31M44 / 32M44 481900 397300 323500 290400 231400 181000 51M44 / 52M44 593600 481400 384900 342100 302800 233700 61M44 / 62M44 757900 617600 494200 438400 386400 292700 71M44 / 72M44 876300 711800 569600 506300 448000 344900 81M44 / 82M44 1152000 984600 840000 775400 659500 559000 CLC/CLL/CLS +45 +35 +25 +20 +10 0 17M44 / 18M44 293800 239000 191300 169800 131600 99100 21M44 / 23M44 347100 283200 227900 203400 159900 123200 31M44 / 32M44 462500 380900 309800 277900 220900 172300 51M44 / 52M44 566800 459100 366500 325500 287800 221400 61M44 / 62M44 723400 588500 469700 415900 365700 275100 71M44 / 72M44 835300 678100 542200 481700 425800 327000 81M44 / 82M44 1101600 941100 802200 740100 628600 531500 CLC/CLL/CLS +45 +35 +25 +20 +10 0 17M44 / 18M44 279800 227200 181300 160700 124100 92800 21M44 / 23M44 330900 269800 216900 193400 151800 116700 31M44 / 32M44 442700 364300 296000 265300 210600 163800 51M44 / 52M44 539900 436900 348300 309100 273000 209500 61M44 / 62M44 688500 559100 445000 393200 344900 257400 71M44 / 72M44 794400 644500 514900 457200 403900 309300 81M44 / 82M44 1049000 895300 762300 702700 595700 502100 CLC/CLL/CLS +45 +35 +25 +20 +10 0 17M44 / 18M44 251000 202800 160900 142200 108800 80400 21M44 / 23M44 297800 242300 194400 173100 135500 103700 31M44 / 32M44 401600 329800 267300 239200 189200 146500 51M44 / 52M44 485000 391500 311300 275800 243200 185800 61M44 / 62M44 617600 499300 394700 347200 302700 221700 71M44 / 72M44 712600 577300 460500 408300 360100 274200 81M44 / 82M44 937100 797100 676000 621700 523800 437600 11

ELECTRICAL SPECIFICATIONS - SINGLE AND PARALLEL COMPRESSOR MODELS MODEL NUMBER COMPRESSOR MODEL 230/3/60 COMP. COND. RLA LRA FLA TOTAL* UNIT AMPS MCA* 460/3/60 COMP. COND. RLA LRA FLA TOTAL* UNIT AMPS MEDIUM TEMP - R22 20H22 06DA537 57.1 266.0 12.8 70.9 86.0 25.6 120.0 6.4 32.5 39.0 25H22 06EA550 87.0 345.0 12.8 100.8 123.0 44.0 173.0 6.4 50.9 62.0 30H22 06EA565 112.0 446.0 12.8 125.8 154.0 56.0 223.0 6.4 62.9 77.0 35H22 06EA575 135.0 506.0 19.2 155.2 189.0 68.0 253.0 9.6 78.1 96.0 40H22 06EA599 189.0 690.0 19.2 209.2 257.0 95.0 345.0 9.6 105.1 129.0 MCA* 17H22 (2) 06DA825 71.2 396.0 12.8 85.0 103.0 35.6 198.0 6.4 42.5 52.0 21H22 (2) 06DA328 79.4 456.0 12.8 93.2 114.0 39.8 228.0 6.4 46.7 57.0 31H22 (2) 06DA537 114.2 532.0 19.2 134.4 163.0 51.2 240.0 9.6 61.3 75.0 51H22 (2) 06EA550 174.0 690.0 25.6 200.6 245.0 88.0 346.0 12.8 101.3 124.0 61H22 (2) 06EA565 224.0 892.0 25.6 250.6 307.0 112.0 446.0 12.8 125.3 154.0 71H22 (2) 06EA575 270.0 1012.0 38.4 309.4 377.0 136.0 506.0 19.2 155.7 190.0 81H22 (2) 06EA599 378.0 1380.0 38.4 417.4 512.0 190.0 690.0 19.2 209.7 258.0 LOW TEMP - R22 25L22 06ER475 87.0 345.0 12.8 100.8 123.0 44.0 173.0 6.4 50.9 62.0 30L22 06ER399 135.0 506.0 12.8 148.8 183.0 68.0 253.0 6.4 74.9 92.0 44L22 (2) 06ER465 174.0 690.0 19.2 194.2 238.0 88.0 346.0 9.6 98.1 121.0 54L22 (2) 06ER475 174.0 690.0 19.2 194.2 238.0 88.0 346.0 9.6 98.1 121.0 61L22 (2) 06ER399 270.0 1012.0 19.2 290.2 358.0 136.0 506.0 9.6 146.1 181.0 MEDIUM TEMP - R404A / R507 20M44 06DA537 57.1 266.0 12.8 70.9 86.0 25.6 120.0 6.4 32.5 39.0 25M44 06EA550 87.0 345.0 12.8 100.8 123.0 44.0 173.0 6.4 50.9 62.0 30M44 06EA565 112.0 446.0 12.8 125.8 154.0 56.0 223.0 6.4 62.9 77.0 35M44 06EA575 135.0 506.0 19.2 155.2 189.0 68.0 253.0 9.6 78.1 96.0 40M44 06EA599 189.0 690.0 19.2 209.2 257.0 95.0 345.0 9.6 105.1 129.0 17M44 (2) 06DA825 71.2 396.0 12.8 85.0 103.0 35.6 198.0 6.4 42.5 52.0 21M44 (2) 06DA328 79.4 456.0 12.8 93.2 114.0 39.8 228.0 6.4 46.7 57.0 31M44 (2) 06DA537 114.2 532.0 19.2 134.4 163.0 51.2 240.0 9.6 61.3 75.0 51M44 (2) 06EA550 174.0 690.0 25.6 200.6 245.0 88.0 346.0 12.8 101.3 124.0 61M44 (2) 06EA565 224.0 892.0 25.6 250.6 307.0 112.0 446.0 12.8 125.3 154.0 71M44 (2) 06EA575 270.0 1012.0 38.4 309.4 377.0 136.0 506.0 19.2 155.7 190.0 81M44 (2) 06EA599 378.0 1380.0 38.4 417.4 512.0 190.0 690.0 19.2 209.7 258.0 LOW TEMP - R404A / R507 25L44 06ER475 87.0 345.0 12.8 100.8 123.0 44.0 173.0 6.4 50.9 62.0 30L44 06ER399 135.0 506.0 12.8 148.8 183.0 68.0 253.0 6.4 74.9 92.0 44L44 (2) 06ER465 174.0 690.0 19.2 194.2 238.0 88.0 346.0 9.6 98.1 121.0 54L44 (2) 06ER475 174.0 690.0 19.2 194.2 238.0 88.0 346.0 9.6 98.1 121.0 61L44 (2) 06ER399 270.0 1012.0 19.2 290.2 358.0 136.0 506.0 9.6 146.1 181.0 * Does not include evaporator loads MCA = Minimum Circuit Ampacity 12

MaxLine ELECTRICAL SPECIFICATIONS - DUAL COMPRESSOR MODELS MODEL NUMBER COMPRESSOR MODEL 230/3/60 COMP. COND. RLA LRA FLA TOTAL* UNIT AMPS MCA* 460/3/60 COMP. COND. RLA LRA FLA TOTAL* UNIT AMPS HIGH TEMP - R22 18H22 (2) 06DA825 35.6 198.0 12.8 49.4 103.0 17.8 99.0 6.4 24.7 52.0 23H22 (2) 06DA328 39.7 228.0 12.8 53.5 114.0 19.9 114.0 6.4 26.8 57.0 32H22 (2) 06DA537 57.1 266.0 19.2 77.3 163.0 25.6 120.0 9.6 35.7 75.0 52H22 (2) 06EA550 87.0 345.0 25.6 113.6 245.0 44.0 173.0 12.8 57.3 124.0 62H22 (2) 06EA565 112.0 446.0 25.6 138.6 307.0 56.0 223.0 12.8 69.3 154.0 72H22 (2) 06EA575 135.0 506.0 38.4 174.4 377.0 68.0 253.0 19.2 87.7 190.0 82H22 (2) 06EA599 189.0 690.0 38.4 228.4 512.0 95.0 345.0 19.2 114.7 258.0 LOW TEMP - R22 46L22 (2) 06ER465 87.0 345.0 19.2 107.2 238.0 44.0 173.0 9.6 54.1 121.0 56L22 (2) 06ER475 87.0 345.0 19.2 107.2 238.0 44.0 173.0 9.6 54.1 121.0 62L22 (2) 06ER399 135.0 506.0 19.2 155.2 358.0 68.0 253.0 9.6 78.1 181.0 HIGH TEMP - R404A / R507 18M44 (2) 06DA825 35.6 198.0 12.8 49.4 103.0 17.8 99.0 6.4 24.7 52.0 23M44 (2) 06DA328 39.7 228.0 12.8 53.5 114.0 19.9 114.0 6.4 26.8 57.0 32M44 (2) 06DA537 57.1 266.0 19.2 77.3 163.0 25.6 120.0 9.6 35.7 75.0 52M44 (2) 06EA550 87.0 345.0 25.6 113.6 245.0 44.0 173.0 12.8 57.3 124.0 62M44 (2) 06EA565 112.0 446.0 25.6 138.6 307.0 56.0 223.0 12.8 69.3 154.0 72M44 (2) 06EA575 135.0 506.0 38.4 174.4 377.0 68.0 253.0 19.2 87.7 190.0 82M44 (2) 06EA599 189.0 690.0 38.4 228.4 512.0 95.0 345.0 19.2 114.7 258.0 LOW TEMP - R404A / R507 46L44 (2) 06ER465 87.0 345.0 19.2 107.2 238.0 44.0 173.0 9.6 54.1 121.0 56L44 (2) 06ER475 87.0 345.0 19.2 107.2 238.0 44.0 173.0 9.6 54.1 121.0 62L44 (2) 06ER399 135.0 506.0 19.2 155.2 358.0 68.0 253.0 9.6 78.1 181.0 * Does not include evaporator loads MCA = Minimum Circuit Ampacity MCA* 13

PHYSICAL DATA - SINGLE AND PARALLEL COMPRESSOR MODELS MODEL NUMBER COMPRESSOR MODEL QTY * COND FANS APPROXIMATE PHYSICAL DIMENSIONS (In) H L D FAN * CONFIG. REC. CAP @ 90% LBS. CONNECTION SIZE (In) LIQ. SUCT. APPROX. WEIGHT (LBS.) HIGH TEMP - R22 20H22 06DA537 2 150-3/4 45-3/4 41-1/2 A 106 7/8 1-5/8 1925 25H22 06EA550 2 150-3/4 45-3/4 41-1/2 A 144 7/8 2-1/8 2000 30H22 06EA565 2 150-3/4 45-3/4 41-1/2 A 182 1-1/8 2-1/8 2140 35H22 06EA575 3 198-3/4 45-3/4 41-1/2 B 220 1-1/8 2-1/8 2385 40H22 06EA599 3 198-3/4 45-3/4 41-1/2 B 295 1-1/8 2-1/8 2525 17H22 (2) 06DA825 2 185 45-3/4 75-3/4 A 144 7/8 2-1/8 2450 21H22 (2) 06DA328 2 185 45-3/4 75-3/4 A 144 7/8 2-1/8 2575 31H22 (2) 06DA537 3 233 45-3/4 75-3/4 B 220 1-1/8 2-1/8 3050 51H22 (2) 06EA550 4 150-3/4 90-3/4 41-1/2 C 295 1-1/8 2-5/8 3500 61H22 (2) 06EA565 4 150-3/4 90-3/4 41-1/2 C 295 1-3/8 2-5/8 3710 71H22 (2) 06EA575 6 198-3/4 90-3/4 41-1/2 D 416 1-5/8 3-1/8 4340 81H22 (2) 06EA599 6 198-3/4 90-3/4 41-1/2 D 500 1-5/8 3-1/8 4750 LOW TEMP - R22 25L22 06ER475 2 150-3/4 45-3/4 41-1/2 A 145 7/8 2-1/8 2000 30L22 06ER399 2 150-3/4 45-3/4 41-1/2 A 145 7/8 2-1/8 2065 44L22 (2) 06ER465 3 233 45-3/4 75-3/4 B 220 1-1/8 3-1/8 2800 54L22 (2) 06ER475 3 233 45-3/4 75-3/4 B 295 1-1/8 3-1/8 3280 61L22 (2) 06ER399 3 233 45-3/4 75-3/4 B 295 1-1/8 3-1/8 3580 HIGH TEMP - R404A / R507 20M44 06DA537 2 150-3/4 45-3/4 41-1/2 A 94 7/8 1-5/8 1925 25M44 06EA550 2 150-3/4 45-3/4 41-1/2 A 128 7/8 2-1/8 2000 30M44 06EA565 2 150-3/4 45-3/4 41-1/2 A 162 1-1/8 2-1/8 2140 35M44 06EA575 3 198-3/4 45-3/4 41-1/2 B 195 1-1/8 2-1/8 2385 40M44 06EA599 3 198-3/4 45-3/4 41-1/2 B 262 1-1/8 2-1/8 2525 17M44 (2) 06DA825 2 185 45-3/4 75-3/4 A 128 7/8 2-1/8 2450 21M44 (2) 06DA328 2 185 45-3/4 75-3/4 A 128 7/8 2-1/8 2575 31M44 (2) 06DA537 3 233 45-3/4 75-3/4 B 195 1-1/8 2-1/8 3050 51M44 (2) 06EA550 4 150-3/4 90-3/4 41-1/2 C 262 1-1/8 2-5/8 3500 61M44 (2) 06EA565 4 150-3/4 90-3/4 41-1/2 C 262 1-3/8 2-5/8 3710 71M44 (2) 06EA575 6 198-3/4 90-3/4 41-1/2 D 370 1-5/8 3-1/8 4340 81M44 (2) 06EA599 6 198-3/4 90-3/4 41-1/2 D 445 1-5/8 3-1/8 4750 LOW TEMP - R404A / R507 25L44 06ER475 2 150-3/4 45-3/4 41-1/2 A 128 7/8 2-1/8 2000 30L44 06ER399 2 150-3/4 45-3/4 41-1/2 A 145 7/8 2-1/8 2065 44L44 (2) 06ER465 3 233 45-3/4 75-3/4 B 195 1-1/8 3-1/8 2800 54L44 (2) 06ER475 3 233 45-3/4 75-3/4 B 262 1-1/8 3-1/8 3280 61L44 (2) 06ER399 3 233 45-3/4 75-3/4 B 262 1-1/8 3-1/8 3580 * See back cover for dimensional drawings. 14

MaxLine PHYSICAL DATA - DUAL COMPRESSOR MODELS MODEL NUMBER COMPRESSOR MODEL QTY * COND FANS APPROXIMATE PHYSICAL DIMENSIONS (In) H L D FAN * CONFIG. REC. CAP @ 90% LBS. CONNECTION SIZE (In) LIQ. SUCT. APPROX. WEIGHT (LBS.) HIGH TEMP - R22 18H22 (2) 06DA825 2 185 45-3/4 75-3/4 A (2) 62 (2) 7/8 (2) 1-3/8 2450 23H22 (2) 06DA328 2 185 45-3/4 75-3/4 A (2) 62 (2) 7/8 (2) 1-5/8 2575 32H22 (2) 06DA537 3 233 45-3/4 75-3/4 B (2) 106 (2) 1-1/8 (2) 1-5/8 3050 52H22 (2) 06EA550 4 150-3/4 90-3/4 41-1/2 C (2) 144 (2) 1-1/8 (2) 2-1/8 3500 62H22 (2) 06EA565 4 150-3/4 90-3/4 41-1/2 C (2) 182 (2) 1-3/8 (2) 2-1/8 3710 72H22 (2) 06EA575 6 198-3/4 90-3/4 41-1/2 D (2) 220 (2) 1-5/8 (2) 2-1/8 4340 82H22 (2) 06EA599 6 198-3/4 90-3/4 41-1/2 D (2) 295 (2) 1-5/8 (2) 2-1/8 4750 LOW TEMP - R22 46L22 (2) 06ER465 3 233 45-3/4 75-3/4 B (2) 106 (2) 1-1/8 (2) 2-1/8 2800 56L22 (2) 06ER475 3 233 45-3/4 75-3/4 B (2) 144 (2) 1-1/8 (2) 2-1/8 3280 62L22 (2) 06ER399 3 233 45-3/4 75-3/4 B (2) 144 (2) 1-1/8 (2) 2-1/8 3580 HIGH TEMP - R404A / R507 18M44 (2) 06DA825 2 185 45-3/4 75-3/4 A (2) 55 (2) 7/8 (2) 1-3/8 2450 23M44 (2) 06DA328 2 185 45-3/4 75-3/4 A (2) 55 (2) 7/8 (2) 1-5/8 2575 32M44 (2) 06DA537 3 233 45-3/4 75-3/4 B (2) 94 (2) 1-1/8 (2) 1-5/8 3050 52M44 (2) 06EA550 4 150-3/4 90-3/4 41-1/2 C (2) 128 (2) 1-1/8 (2) 2-1/8 3500 62M44 (2) 06EA565 4 150-3/4 90-3/4 41-1/2 C (2) 162 (2) 1-3/8 (2) 2-1/8 3710 72M44 (2) 06EA575 6 198-3/4 90-3/4 41-1/2 D (2) 195 (2) 1-5/8 (2) 2-1/8 4340 82M44 (2) 06EA599 6 198-3/4 90-3/4 41-1/2 D (2) 262 (2) 1-5/8 (2) 2-1/8 4750 LOW TEMP - R404A / R507 46L44 (2) 06ER465 3 233 45-3/4 75-3/4 B (2) 94 (2) 1-1/8 (2) 2-1/8 2800 56L44 (2) 06ER475 3 233 45-3/4 75-3/4 B (2) 128 (2) 1-1/8 (2) 2-1/8 3280 62L44 (2) 06ER399 3 233 45-3/4 75-3/4 B (2) 128 (2) 1-1/8 (2) 2-1/8 3580 * See back cover for dimensional drawings. 15

MaxLine DRAWINGS 5 FAN CONFIGURATION "A" 50 CONTROL BOX PIPING CONTROL BOX ALL PIPING CONNECTIONS 20 6 3/4 22 1/2 W 12 A L 2-1/2 Dia Lifting Holes 5 FAN CONFIGURATION "B" 50 CONTROL BOX PIPING CONTROL BOX ALL PIPING CONNECTIONS 20 6 3/4 22 1/2 W 6 12 A L 2-1/2 Dia Lifting Holes 5 FAN CONFIGURATION "C" 50 CONTROL BOX PIPING CONTROL BOX ALL PIPING CONNECTIONS 20 6 3/4 44 1/2 W 12 A L 2-1/2 Dia Lifting Holes 5 FAN CONFIGURATION "D" 50 CONTROL BOX PIPING CONTROL BOX ALL PIPING CONNECTIONS 20 6 3/4 44 1/2 W 6 12 A L 2-1/2 Dia Lifting Holes Commercial Refrigeration A member of the United Technologies Corporation family Stock Symbol - UTX Manufacture reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 221 South Berry St., Brea, CA 92821 Tel: (714) 529-9571 Fax: (714) 529-7203

Commercial Refrigeration MidLine Air Cooled Condensing Units 7 to 20 HP Literature No. - C310.2 September, 2006 MEA Medium to Low Temperature Units Carlyle semi-hermetic Compressors

MidLine The outdoor housing of our condensing units are engineered to allow easy access to all components. Quick removal of top and side panels allows quick access to everything. The hinged control panel door swings wide open for maximum clearance while the unit is being serviced. The large control panel has abundant space for the controls you choose. They are intelligently arranged and laid out in a logical fashion which is easy to understand and work with. Each control and wire is clearly marked with a name or number as shown on the wiring diagram which is conveniently affixed to the control panel door. CONTROL VOLTAGE TRANSFORMER CONTROL CIRCUIT FUSES DEFROST CLOCK* HINGED DOOR RUSSAVER PRESSURE CONTROL* COMPRESSOR CONTACTOR POWER TERMINAL BLOCK EVAP FAN MOTOR CONTACTOR* BLOCK OUT RELAY* EVAPORATOR DEFROST CONTACTORS* EVAPORATOR SEQUENCING RELAYS* NON-FUSED DISCONNECT SWITCH* DOOR INTERLOCK* EVAPORATOR FAN AND HEATER SUB-CIRCUIT FUSING* CONDENSER FAN MOTOR CAPACITORS 2

MODEL NUMBER NOMENCLATURE CM L C 20 L 44 CM STYLE UNIT STYLE OF UNIT E = Indoor Unit L = Outdoor unit w/flooded controls S = Outdoor unit w/floating Head pressure controls C = Outdoor unit w/no head pressure controls COMPRESSOR STYLE C = Carlyle REFRIGERANT TYPE 22 = R-22 44 = R-404A 57 = R-507 OPERATING RANGE H = High Temp (+10 F to +45 F Suction Temp) M = High/Medium Temp (-10 F to +45 F Suction Temp) NOMINAL HORSEPOWER ELECTRICAL COMPONENTS CONDENSER PIPING COMPONENTS RECEIVER HOUSING Fusible plug All weather housing Control panel - with hinged door Raised galvanized steel base FEATURES AT A GLANCE Crankcase heater Oil failure control - as required High-Low pressure control - manual(high)/automatic(low)rest Compressor contactor Control circuit fuses - standard 230/1 Power terminal block Copper tubes with Aluminum fins Subcooling circuit Fan motor - PSC overload protection Fan blade - individually balanced Fan guard - split for easy motor access: UL listed Suction line filter Suction line vibration eliminator Liquid line filter/drier Sight glass/moisture indicator Discharge line vibration eliminator Inlet and outlet isolation valves Energy-Saver - all ambient energy saver LOW AMBIENT Pressure fan cycling control - not available on 3HP - 6HP low temps. CONTROLS Flooded condenser UL/cUL listed all models TESTING Leak detection, Dielectric & Run test Dry nitrogen holding charge OPTIONS: 4 year extended compressor warranty Air defrost time clock Compressor unloading Copper or coated condenser fins Crankcase pressure regulator Electric Defrost with heater contactors, timer, block out relay Evap sub circuit fusing Fused disconnect Heated and insulated receiver - not UL MODEL CME CMC CMS OPTION OPTION OPTION OPTION OPTION OPTION OPTION N/A OPTION OPTION N/A OPTION OPTION Hot Gas Defrost components Liquid line solenoid valve Oil separator Oversized reciever Phase loss monitor Electronic oil saftey control Spring loaded relief valve Staninless steel hoses Suction line accumulator Fused Disconnect N/A 3