Control Panels and Fire Detection Equipment

Similar documents
CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

An introduction to... Sigma

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

Conventional Fire Control Panel with Extinguishant Control Unit. Operation and Maintenance Manual SIGMA-2-M3-ECU SIGMA-4-M3-ECU SIGMA-8-M3-ECU

Application, Installation, Operation & Maintenance Manual

Installation, Operating and Maintenance Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

SALES SUPPORT DOCUMENT

Sigma XT+ Extinguishant Control Panel. Operation and Maintenance Manual

System 800 Addressable Fire Detection & Alarm System

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Operation and Maintenance Manual

Sigma XT. Extinguishant Control Panel. User Manual Man-1091 Issue 03 October 2009 (K11031M2, K11031F2)

MINERVA MX. 800 Series Ancillary Equipment

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

LaserFOCUS VLF-250 Engineering Specification

Addressable Fire Alarm Control Panel

Conventional Releasing Control Panel

Reliably Advanced Extinguishing Control

Intelligent Security & Fire Ltd

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

GAS FLOODING SYSTEM FOR CIFF AT BASEMENT

Reliably Advanced Extinguishing Control

End To End Optical Beam Smoke Detector. Additional Information

The supplier and installer of the system should be approved by the local civil defence authority.

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

Different types of Fire Alarm System

ZSC100 Gas Detection and Alarm System Controller

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

User Operation Manual

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Intelligent addressable fire alarm control panel

5000 INSTALLATION GUIDE

OPERATION AND INSTALLATION MANUAL

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

DCS-100. intelligent damper control & monitoring system

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Multiple Input and Output Modules

TX24-10A. Intelligent PSU Installation and Operation Manual. TANDA UK Technology Copyright 2016, All right reserved.

Why Hart XL Aspirating Smoke Detection?

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

D7024 Fire Alarm Control Panel

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

Conventional Fire Control Panel

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

Conventional Smoke Detectors KFAPO

PREMIER EX8 INSTALLATION MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4 INSTALLATION MANUAL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Smoke Vent Control Panel PCB4 V4 Installation Manual

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

Quick Selection Guide Fire Systems LSN Periphery

Instruction manual. W440 AIS Sart Sniffer

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

Precept Marine Control Panel Application Guide

Conventional & Twin-wire Fire System

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

2018 Johnson Controls. Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Switzerland DUO-CEL

ORION Mini-Rep INSTALLATION MANUAL

RELEASE DEVICE CONTROLS

Intelligent Security & Fire Ltd

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Industries. As a premier global manufacturing company, we believe that great brands are

EX8. Instruction Manual: COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 AND EN54 PARTS 2 & 4

Specification/ Data Sheet

Boiler Room Control THE MERLIN RANGE GAS DETECTION EQUIPMENT ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

Sita200plus. 200detectors. Single loop analogue addressable System

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

Doc. No Part No Rev. U * T*

1) This manual covers 4400, 5400 and 6400 fire alarm systems. The differences are described in the appropriate sections.

Consultant Specification AGILE Wireless Fire Detection System

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012

Doc. No.: OMPII.DOC Rev. 2 Written By: Raj Patel Checked By: AJC Approved By: JBJ Date: 03/05/05

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

Actionpac 60/120 (LNS Standard)

On the job around the clock 24/7: Fire detection systems

Product Catalogue 2017 Product Catalogue 1

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Natural Ventilation Controller with 24vDC drive NVC-1204

MODEL B2 INSTALLATION MANUAL

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

For Complete Fire and Gas Solutions

Installation & Operation

Technical Data Sheet

Fire Product Catalog

100 Series Gas Ventilation Interlock System

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

Transcription:

Control Panels and Fire Detection Equipment

Quaestor-SZU... Page 03 Quaestor-SZU Ancillary Board.... Page 04 Quaestor-MZE BS... Page 05 Quaestor-SZE BS... Page 06 Quaestor-SZE Ancillary Board... Page 07 Venator-DU Detectors... Page 08 Detectors... Page 09 Contacts... Page 10

Quaestor-SZU Extinguishant Control Panels QUAESTOR -SZU Extinguishant Control Panel Product Overview Designed and manufactured to the highest standards in a quality controlled environment and with UL approval the Quaestor-SZU releasing panel offers outstanding value and performance for all small to medium fixed firefighting installations. With 3 initiation circuits as standard, release can be configured to activate from any combination of detection zone inputs to allow (among other combinations) any 2 from 3 type activations such as would be required for detection in ceiling void, room and floor void applications. The extensive configuration options of the Quaestor-SZU allow functionality of the system to be extensively modified. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until release for added user safety. SHW80001 The countdown timer is duplicated on up to seven remote status units to provide local indication of the system status. SHS80001 Programmable Functions Access Level 2 Test Zones 1 to 3 Disable Zones 1 to 3 Disable 1st Stage Alarms Disable Pre-activated 1st Stage Relay Disable Pre-activated 2nd Stage Relay Disable Extract Fan Output Disable Manual Release Input Disable Releasing Sub System Activate Extract Fan Output Activate Alarm Delays Access Level 3 Sounder Delay Coincidence Detection Disable Panel Features Zone Alarm Delays (Detectors) Zone Alarm Delay (Call stations) Configure Zone for I.S Barrier Use Zone Short Circuit Alarm Zone Non Latching Zone Inputs Delay Extinguishant Release Time Delay Extinguishant Release Duration Timer Extinguishant Reset Delay Timer With all of the electronics mounted on a single, easy, removable, steel plate Quaestor-SZU panels are both robust and easy to install. Features UL864 Three initiation circuits as a standard Any single zone or any combinations of zones can be configured to release Configurable first stage NAC delays Zero time delay upon manual release option Compatible with I.S. barriers Non-latching zone input option to receive signals from other systems such as aspirating equipment Configurable releasing delays up to 60 seconds in 5 second steps Configurable releasing delays up to 5 minutes in 5 second steps Countdown timer shows time remaining until release Support up to 7, 4 wire status indicators Built in Extract Fan control page 03 Safety Hi-Tech

Quaestor-SZU Extinguishant Control Panels Quaestor-SZU Ancillary Board The Quaestor-SZU Ancillary Board is compatible with all Quaestor control panels. The board provides volt free normally open contacts allowing control of sub-systems and plant remotely from the main panel over a two wire data bus. Ancillary boards require only a two core data cable from the main control panel and a two core power cable from the main panel. Up to 7 Ancillary boards can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. The total length of the data cable from the main panel to the last repeater must not exceed 4000 feet. A mixture of status units and Ancillary boards, up to a maximum of 7 of each type, can be connected to the serial data bus. The operation of this product is intended for indoor use only. The wiring diagram below illustrate connections for all SHA80001 models of the Quaestor-SZU Ancillary board Wiring Diagram 1-1 Quaestor-SZU Ancillary Board Connections: Connect (+) 24V DC to (+) 24V DC of the Quaestor-SZU Releasing Fire Control Panel. Connect Fire Zone Relays to detection zones of the Quaestor-SZU Releasing Fire Control Panel. Connect (+) IN to (+) OUT of the Quaestor-SZU Releasing Fire Control Panel. Connect (-) 24V DC to (-) 24V DC of the Quaestor-SZU Releasing Fire Control Panel. Connect these relay-terminals to releasing circuits of the Quaestor-SZU Releasing Fire Control Panel. Connect (-) IN to (-) OUT of the Quaestor-SZU Releasing Fire Control Panel. + - + - + - + - 24V 24V Z1 Z2 Z3 MAN DISAB REL ACT HOLD EXTR MAN RS485 RS485 DC DC FIRE FIRE FIRE MODE REL OUT IN Connect ( + ) 24V DC to ( + ) 24V DC of the next Quaestor-SZU Status Unit or Quaestor-SZU Ancillary Board. Connect ( + ) OUT to ( + ) IN of the next Quaestor-SZU Status Unit or Quaestor-SZU Ancillary Board. Connect ( - ) 24V DC to ( - ) 24V DC of the next Quaestor-SZU Status Unit or Quaestor-SZU Ancillary Board. Connect ( - ) OUT to ( - ) IN of the next Quaestor-SZU Status Unit or Quaestor-SZU Ancillary Board. page 04 Safety Hi-Tech

Quaestor-MZE Extinguishant Control Panels QUAESTOR -MZE Multi-Area Extinguishant Control Panel Product Overview Quaestor-MZE control panels are multi-area extinguishant control panels complying with EN 12094-1, EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface. Control Panels All extinguishant may have up to 7 serially connected Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Quaestor CP Ancillary boards (SHA00002) or Quaestor CP Sounder boards (SHA00003) to the RS485 serial bus. See data sheet DS39 and DS48. BS-EN12094-1 KM 96761 SHA70001 SHA80002 Features Approved to EN12094-1, EN54-2 and EN54-4 2, 4 or 8 detection zones 1 to 4 extinguishant areas Dual Extinguishant outputs for each area (configurable as Main/Reserve) First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select (door interlock) input Monitored remote Released pressure switch input Monitored remote Low pressure switch input Monitored Abort input Serial connection for Si status units and ancillary boards, (SHA70001) SHA80003 page 05 Safety Hi-Tech

Quaestor-SZE Extinguishant Control Panels QUAESTOR -SZE Extinguishant Control Panel Product Overview Designed and manufactured to the highest standards in a quality controlled environment and with European EN12094-1 approvals, the Quaestor-SZE extinguishant releasing panel offers outstanding value and performance for all small to medium fixed firefighting installations. With 3 detection zones as standard, extinguishant release can be configured to activate from any combination of detection zone inputs to allow (among other combinations) any 2 from 3 type activations as would be required for detection in ceiling void, room and floor void applications. BS-EN12094-1 KM 96761 SHW70001 Programmable Functions Access Level 2 Test Zones 1 to 3 Disable Zones 1 to 3 Disable 1st Stage Alarms Disable Pre-activated 1st Stage Relay Disable Pre-activated 2nd Stage Relay Disable Extract Fan Output Disable Manual Release Input Disable Extinguishant Sub System Activate Extract Fan Output Activate Alarm Delays Access Level 3 Sounder Delay Coincidence Detection Disable Panel Features Zone Alarm Delays (Detectors) Zone Alarm Delay (Call stations) Configure Zone for I.S Barrier Use Zone Short Circuit Alarm Zone Non Latching Zone Inputs Delay Extinguishant Release Time Delay Extinguishant Release Duration Timer Extinguishant Reset Delay Timer SHS70007 The extensive configurations options of the Quaestor- SZE allow the functionality of the system to be extensively modified while still complying with the requirements of the controlling standard for the equipment (EN12094-1, EN54-2 and EN54-4). The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until release for added user safety. The countdown timer is duplicated on up to seven remote status units to provide local indication of the system status. With all of the electronics mounted on a single, easy, removable, steel plate Quaestor-SZE panels are both robust and easy to install. Features Approved to EN12094-1, EN54-2 and EN54-4 Three detection zones as standard Any single zone or any combinations of zones can be configured to release Configurable first stage sounders delays Zero time delay upon manual release option Compatible with I.S. barriers Non-latching zone input option to receive signals form other systems such as aspirating equipment Configurable releasing delays up to 60 seconds in 5 second steps Configurable releasing delays up to 5 minutes in 5 second steps Countdown timer shows time remaining until release Support up to 7, 4 wire status indicators Built in Extract Fan control 06 Safety Hi-Tech

Quaestor-SZE Extinguishant Control Panels Quaestor-SZE Ancillary board There is sometimes a requirement to extend signals from the extinguishing system for additional plant control or other signalling applications such as interfaces to BMS systems or house fire alarm systems. The Quaestor-SZE is equipped with a selection of volt free contacts which are often adequate for this purpose. For applications that require more outputs from the system, the Quaestor- SZE ancillary board is available. Up to 7 ancillary boards may be connected to the status unit serial bus to provide distributed control and signalling at multiple locations if required. Each output has an LED indicator which shows which outputs are operated. The Quaestor-SZE ancillary board contains volt free changeover contacts for signalling of the following: SHA70001 Quaestor Ancillary PCB Zone 1 fire Zone 2 fire Zone 3 fire Manual only mode Disablement active Released Activated Manual release operated Extract fan operated Hold activated One ancillary board can be mounted within a Quaestor-SZE control panel on push-in standoffs behind the main equipment chassis. Alternatively, Quaestor-SZE ancillary boards are available in enclosures that match the styling of the control panel. + - + - 24V DC 24V DC PF Z1 FIRE Z2 FIRE Z3 FIRE MAN MODE DISAB REL ACT HOLD EXTR MAN REL + - RS485 OUT + - RS485 IN Example System Schematic Detection Zone 3 Detection Zone 2 1st Stage Sounders 2nd Stage Sounders Hold Manual Release Door Interlock MAN Z1 Z2 Z3 MAN DISAB REL ACT REL EXTR HOLD Low Pressure Switch Released Pressure Switch Activate Extinguisher OK PROCESSOR RESET FUSE FAIL ADDRESS Detection Zone 1 System Status and Control 4 Core Addressable House Fire Alarm Ancillary Board BMS Interface EN12094-1 Approved Control Unit System Status and Control System Status and Control Ancillary Board 4 Core 07 Safety Hi-Tech

Venator-DU Fire Detection Equipment VENATOR -DU Fire Detectors Product Overview Venator-DU incorporates well-proven technologies, together with advances in materials and electronics technology, including an IC based. Having a wide operating voltage of 9-33V, the Ventator-DU detectors can be integrated into security systems, when used with a relay base. The Venator-DU wide voltage range consists of ionisation, integrating ionisation and optical smoke detectors, 2 grades of heat detector and a range of bases. All detectors are equipped with flashing LED. All detectors and bases are listed by UL and ULC. Venator-DU Ionisation Smoke Detector Venator-DU Optical Smoke Detector Venator-DU Heat Detector Venator-DU Normal Base Venator-DU Base with Relay page 08 Safety Hi-Tech

Fire Detection Equipment VENATOR -DE Fire Detectors Product Overview incorporates well-proven technologies, together with advances in materials and electronics technology, including an IC based. Having a wide operating voltage of 9-33V, the Ventator-DU detectors can be integrated into security systems, when used with a relay base. The wide voltage range consists of ionisation, integrating ionisation and optical smoke detectors, 2 grades of heat detector and a range of bases. All detectors are equipped with flashing LED. All detectors and bases and call points are approved EN4-7:2000 and EN4-5:2000 0832 Ionisation Smoke Detector Optical Smoke Detector Heat Detector Normal Base Base with Relay Manual Call Point page 09 Safety Hi-Tech

CertifiedSafetyPassion Our mission is to be successful by embracing the philosophies of high quality, advanced techniques, and customer service with a range of products and services always focused on safety and environmental sustainability. The performance of all our products, system components and design software programs are certified by internationally recognized independent laboratories, ensuring that the complete system is reliable and safe. SAFETY HI-TECH is a registered trademark of Safety Hi-Tech srl. UL Listing Mark is a registered trademark of Underwriters Laboratories Inc. Quaestor, Venator and Certified Safety Passion are trademarks of Safety Hi-Tech srl. Safety Hi-Tech Srl Via degli Olmetti, 5B 00060 Formello Italy, European Union Tel: +39 086319407.20 Fax: +39 086319407.24 Website: www.safetyhitech.com customer.service@safetyhitech.com