Tennessee Valley Property Inspections

Similar documents
Axiom Property Inspections

Inspector Gadget Homes

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny

Extra Mile Inspection, Inc.

Inside Out Home Inspections

Watson Home Inspection Services, LLC.

Space Coast Home Inspections LLC

Cascade Inspection Services, LLC

Troy's Home Inspection Services LLC

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -

Bayshore House Inspections LLC

Hearth and Homes Inspections, llc

MHI Services Inc. Property Inspection Report

Jeff Brown Inspections

All In One Home Inspections

FAIRA TRANSPARENCY REPORTS S 236th St, 10-5, Kent, WA 98032

Canadian Property Inspections

FAIRA TRANSPARENCY REPORTS th St SW, Lynnwood, WA 98037

FAIRA TRANSPARENCY REPORTS Brighton Pl, Mukilteo, WA 98275

RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: -

FAIRA TRANSPARENCY REPORTS Alaskan Way, 514, Seattle, WA 98101

SPS Home Inspections, LLC

FAIRA TRANSPARENCY REPORTS NE 117th Pl, #F8, Kirkland, WA 98034

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

FAIRA TRANSPARENCY REPORTS S 248th Pl, Des Moines, WA March 12, 2018

Final Phase Inspection

FAIRA TRANSPARENCY REPORTS. November 21, 2016

FAIRA TRANSPARENCY REPORTS SE 265th St, Covington, WA October 10, 2017

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017

RW West Consultants. Property Inspection Report

FAIRA TRANSPARENCY REPORTS Spruce Way, Lynnwood, WA August 21, 2017

FAIRA TRANSPARENCY REPORTS nd Ave S, E-2, SeaTac, WA 98198

FAIRA TRANSPARENCY REPORTS W Manor Pl, #413, Seattle, WA August 25, 2017

Coast Home Inspection

FAIRA TRANSPARENCY REPORTS th St SE, Lake Stevens, WA June 14 th, 2017

FAIRA TRANSPARENCY REPORTS NE 108th St, Redmond, WA April 4 th 2017

FAIRA TRANSPARENCY REPORTS. November 21, 2016

FAIRA TRANSPARENCY REPORTS th Ave S, A304, Des Moines, WA March 13, 2018

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092

Amendment to the Inspection Report

FAIRA TRANSPARENCY REPORTS Waverly Dr, Snohomish, WA May 10 th, 2017

FAIRA TRANSPARENCY REPORTS Country Club Dr, B-203, Mill Creek, WA April 5 th, 2017

FAIRA TRANSPARENCY REPORTS Greenwood Ave N, N304, Seattle, WA March 21, 2018

FAIRA TRANSPARENCY REPORTS SE 279th St, Maple Valley, WA March 7, 2018

FAIRA TRANSPARENCY REPORTS W Villa Monte Dr, Mukilteo, WA August 8 th, 2017

FAIRA TRANSPARENCY REPORTS Stone Ave N, #205, Seattle, WA 98133

FAIRA TRANSPARENCY REPORTS SE 240th Pl, Maple Valley, WA June 5th, 2017

FAIRA TRANSPARENCY REPORTS st Pl SE, Sammamish, WA May 18 th, 2017

FAIRA TRANSPARENCY REPORTS SE Woody Creek Ln, Snoqualmie, WA October 12, 2017

FAIRA TRANSPARENCY REPORTS NE 182nd St, C101, Kenmore, WA 98028

FAIRA TRANSPARENCY REPORTS st Ave, #605, Seattle, WA June 2 nd, 2017

FAIRA TRANSPARENCY REPORTS

FAIRA TRANSPARENCY REPORTS S 284th Ln, #H204, Federal Way, WA March 12, 2018

FAIRA TRANSPARENCY REPORTS th Ln NE, Issaquah, WA February 1, 2018

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

FAIRA TRANSPARENCY REPORTS

FAIRA TRANSPARENCY REPORTS th Ave, Seattle, WA April 28 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave S, Auburn, WA June 15 th, 2017

Excellent Home Inspection Services, LLC

FAIRA TRANSPARENCY REPORTS. 553 Chelan Pl NE, Renton, WA March 3 rd, 2018

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

FAIRA TRANSPARENCY REPORTS SE 41st Ln, E203, Bellevue, WA April 7 th, 2017

FAIRA TRANSPARENCY REPORTS th St SE, #13A, Auburn, WA January 25, 2018

FAIRA TRANSPARENCY REPORTS th Dr NE, Marysville, WA June 14 th, 2017

FAIRA TRANSPARENCY REPORTS S 237th St, Kent, WA November 28, 2017

FAIRA TRANSPARENCY REPORTS Bothell Everett Hwy, D304, Bothell, WA February 6, 2018

FAIRA TRANSPARENCY REPORTS. 405 SW 346th Pl, Federal Way, WA Nov 09th, 2015

1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109

FAIRA TRANSPARENCY REPORTS Wells Ct S, Renton, WA 98055

FAIRA TRANSPARENCY REPORTS S 272nd St, #39, Kent, WA September 1 st, 2017

FAIRA TRANSPARENCY REPORTS th Ave SE, Bothell, WA 98012

FAIRA TRANSPARENCY REPORTS nd Ave SW, Burien, WA October 26 th, 2017

FAIRA TRANSPARENCY REPORTS. February 28 th, 2018

FAIRA TRANSPARENCY REPORTS. January 27 th, 2017

FAIRA TRANSPARENCY REPORTS Fairview Ave E, #304, Seattle, WA June 7 th, 2017

FAIRA TRANSPARENCY REPORTS Highland Dr, Bellevue, WA 98006

FAIRA TRANSPARENCY REPORTS rd Pl SE, Maple Valley, WA April 4 th, 2017

fieldwork report contains the Functional

FAIRA TRANSPARENCY REPORTS S 259th St, Des Moines, WA October 2, 2017

FAIRA TRANSPARENCY REPORTS Harbour Pointe Blvd, #301h, Mukilteo, WA 98275

This Report Was Prepared For: Property Address Inspected:

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

FAIRA TRANSPARENCY REPORTS W James St, 8, Kent, WA 98032

FAIRA TRANSPARENCY REPORTS th Pl W, Lynnwood, WA 98087

FAIRA TRANSPARENCY REPORTS th Ave SE, Renton, WA June 13 th, 2017

FAIRA TRANSPARENCY REPORTS th Dr NE, Lake Stevens, WA April 4th, 2017

Inspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651)

John Sample. Property Address: 123 Main St. Alpharetta GA Inspector: Jason David. Residential Inspector of America, Inc.

Canadian Property Inspections

FAIRA TRANSPARENCY REPORTS th St SW, 301, Lynnwood, WA May 31 st, 2017

FAIRA TRANSPARENCY REPORTS NE 178th St, Lake Forest Park, WA May 2 nd, 2017

Inspection Report 123 My Street Midland, GA

FAIRA TRANSPARENCY REPORTS. March 14 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave N, Edmonds, WA January 19 th, 2018

FAIRA TRANSPARENCY REPORTS. 706 N 103rd St, Seattle, WA August 14, 2017

Home Inspection Report

Home Inspection Report

FAIRA TRANSPARENCY REPORTS S 298th St, Auburn, WA March 28 th, 2017

BISHOP HOME INSPECTIONS, LLC. Phone (269) / Fax (269) / Website: bishophomeinspection.

FAIRA TRANSPARENCY REPORTS SE 225th St, Maple Valley, WA June 2nd, 2017

Transcription:

Cover Page Tennessee Valley Property Inspections Property Inspection Report Inspection prepared for: Billy Bob & Eula May Jones Date of Inspection: 1/9/2017 Time: 0900 Size: 4900sf Weather: 30 degrees. Sunny Home faces the east Also inspected by Matthew Fox, Lic #1576 Inspector: Bruce Hull License #526 P.O. Box 1783, Spring Hill, TN 37174 Phone: 615.476.4548 Email: bruce.hull.tvpi@gmail.com www.tennesseevalleypropertyinspections.com

Report Summary Report Summary The summary below consists of potentially significant findings. These findings can be a safety hazard, a deficiency requiring a major expense to correct or items I would like to draw extra attention to. The summary is not a complete listing of all the findings in the report, and reflects the opinion of the inspector. Please review all pages of the report as the summary alone does not explain all of the issues. All repairs should be done by a licensed & bonded tradesman or qualified professional. I recommend obtaining a copy of all receipts, warranties and permits for the work done. Interior Areas Page 5 Item: 4 Doors Some interior doors were binding at frames. Pedestrian egress doors had keyed interior deadbolt. These doors should require no special skill, tool, or knowledge to operate. Page 6 Item: 5 Electrical Confirm function of all fixtures not functioning at the time of inspection. Page 6 Item: 7 Stairs & Handrail Railing was loose at the interior stairs. Railing was not installed to modern building standards. Page 8 Item: 11 Window Condition Some window pulleys were sticking. It is possible that this will cease with window use. Rot was noted at the base of the some of the lower window sashes in Florida room Page 9 Item: 12 Floor Condition Moisture intrusion noted at southern French door in library. Bedrooms Page 10 Item: 4 Doors Door were binding in frame upstairs. Bathroom Page 12 Item: 7 Floor Condition Seal base of tub at flooring junction north upstairs Page 13 Item: 11 Sinks Stopper is missing/inoperable in half bath Kitchen Page 15 Item: 3 Garbage Disposal The unit makes irregular noise. This may be a foreign object stuck in the disposal. Page 17 Item: 17 GFCI GFCI did not respond to test at south side, suggest replacing for safety. Laundry Page 19 Item: 4 GFCI No GFCI protection present, suggest installing GFCI protected receptacles for safety. Heat/AC Page 22 Item: 4 Enclosure Plenum for the main package unit needed to be attached and sealed to the exterior wall. Page 22 Item: 5 Venting Vent on the 1999 package unit was heavily corroded. Page 23 Item: 6 Gas Valves Gas line to the furnace was corroded. Line should be over sprayed to prevent further corrosion and eventual leaks from forming. Page 23 Item: 8 AC Compress Condition The insulation is missing or damaged at exterior refrigerant line. Attic Page 32 Item: 2 Structure Moisture stains at flooring in area of furnace tested damp at time of inspection. Page 33 Item: 6 Electrical Missing smoke detector Page 1 of 45

Exterior Areas Page 34 Item: 1 Doors Left side casing at the front entry door was decayed at the base. Page 34 Item: 2 Window Condition All window screens were missing. Page 35 Item: 3 Siding Condition Gas and a/c line penetrations of the exterior wall should be sealed to prevent moisture intrusion. Page 36 Item: 4 Eaves & Facia Aluminum trim piece at the east peak was bent away from the fascia. Grounds Page 37 Item: 3 Vegetation Observations Prune or remove any plants that are in contact or proximity to home to eliminate pathways of wood destroying insects. Page 37 Item: 7 Grounds Electrical Left side back patio light fixture was not functioning. Southwest corner security lights were not functioning. Page 38 Item: 8 GFCI GFCI at the back patio wall would not trip and should be replaced. Page 39 Item: 11 Water Pressure High pressure. 85 Normal range for residential is 45-75. Page 39 Item: 12 Pressure Regulator We recommend the installation of a pressure regulator. Crawlspace Page 41 Item: 1 Crawlspace Open junction boxes were noted in southeastern and northeastern crawl Moisture barrier was missing from some areas of the crawlspace. Dryer vent was pinched closed in the area of the laundry room floor joists. This will prevent adequate propulsion of lint and humidifier air. Page 42 Item: 4 Plumbing Evidence of leakage detected in area of laundry room and master bathroom and requires review and repair by a qualified contractor. Page 43 Item: 7 Framing Improper cutting/over notching of floor joist noted in area of laundry room in northeast crawl. Recommend review and repair by a qualified contractor. Page 2 of 45

We appreciate the opportunity to conduct this inspection for you! Please carefully read your entire Inspection Report. Call us after you have reviewed your report, so we can go over any questions you may have. Remember, when the inspection is completed and the report is delivered, we are still available to you for any questions you may have, throughout the entire closing process. Properties being inspected do not "Pass" or "Fail. - The following report is based on an inspection of the visible portion of the structure; inspection may be limited by vegetation and possessions. Depending upon the age of the property, some items like GFCI outlets may not be installed; this report will focus on safety and function, not current code. This report identifies specific non-code, non-cosmetic concerns that the inspector feels may need further investigation or repair. For your safety and liability purposes, we recommend that licensed contractors evaluate and repair any critical concerns and defects. Note that this report is a snapshot in time. We recommend that you or your representative carry out a final walk-through inspection immediately before closing to check the condition of the property, using this report as a guide. Page 3 of 45

1. Attendance 2. Home Type 3. Occupancy Inspection Details In Attendance: Client present Buyer Agent present Selling Agent present (owner) Home Type: Single Family Home Occupancy: Occupied - Furnished Page 4 of 45

Interior Areas The Interior section covers areas of the house that are not considered part of the Bathrooms, Bedrooms, Kitchen or areas covered elsewhere in the report. Interior areas usually consist of hallways, foyer, and other open areas. Within these areas the inspector is performing a visual inspection and will report visible damage, wear and tear, and moisture problems if seen. Personal items in the structure may prevent the inspector from viewing all areas on the interior. The inspector does not usually test for mold or other hazardous materials. A qualified expert should be consulted if you would like further testing. 1. Ceiling Fans 2. Closets 3. Door Bell 4. Doors Operated normally when tested. Some interior doors were binding at frames. Pedestrian egress doors had keyed interior deadbolt. These doors should require no special skill, tool, or knowledge to operate. Page 5 of 45

5. Electrical Confirm function of all fixtures not functioning at the time of inspection. 6. Smoke Detectors 7. Stairs & Handrail Railing was loose at the interior stairs. Railing was not installed to modern building standards. Page 6 of 45

8. Ceiling Condition Materials: There are drywall ceilings noted. Nail pops and drywall tape separation noted at bonus room upstairs 9. Wall Condition 10. Fireplace Materials: Drywall walls noted. Materials: Den Library The room contains a vent free type of fireplace. It should not be operated for more than 2-4 hours at a time because of the inherent CO poisoning possibility. Page 7 of 45

11. Window Condition Den Library Materials: Wood framed double hung window noted. Some window pulleys were sticking. It is possible that this will cease with window use. Rot was noted at the base of the some of the lower window sashes in Florida room Page 8 of 45

12. Floor Condition Materials: Hardwood flooring is noted. Moisture intrusion noted at southern French door in library. Page 9 of 45

Bedrooms The main area of inspection in the bedrooms is the structural system. This means that all walls, ceilings and floors will be inspected. Doors and windows will also be investigated for damage and normal operation. Personal items in the bedroom may prevent all areas to be inspected as the inspector will not move personal items. 1. Locations 2. Ceiling Fans 3. Closets Locations: Master bedroom South bedroom West bedroom East bedroom 4. Doors Door were binding in frame upstairs. 5. Electrical 6. Floor Condition Flooring Types: Carpet is noted. 7. Smoke Detectors Page 10 of 45

8. Wall Condition 9. Window Condition 10. Ceiling Condition Materials: Drywall walls noted. Materials: Wood framed double hung window noted. Materials: There are drywall ceilings noted. Page 11 of 45

Bathroom Bathrooms can consist of many features from jacuzzi tubs and showers to toilets and bidets. Because of all the plumbing involved it is an important area of the house to look over. Moisture in the air and leaks can cause mildew, wallpaper and paint to peel, and other problems. The home inspector will identify as many issues as possible but some problems may be undetectable due to problems within the walls or under the flooring.. 1. Locations Locations: Master Bathroom Half bathroom Hall Bathroom north upstairs Upstairs Hall South Bathroom 2. Ceiling Condition Materials: There are drywall ceilings noted. 3. Doors 4. Electrical 5. GFCI GFCI in place and operational 6. Exhaust Fan 7. Floor Condition Materials: Carpet is noted. Ceramic tile is noted. Cracking noted in ceramic tiles in area of master tub/bath junction Seal base of tub at flooring junction north upstairs Page 12 of 45

8. Plumbing 9. Showers 10. Bath Tubs Tub Whirlpool Debris was ejected from the jets during operation, recommend having circulation system professionally cleaned prior to use. 11. Sinks Stopper is missing/inoperable in half bath Page 13 of 45

12. Toilets Tank loose and may need resecured upstairs south 13. Window Condition Materials: Wood framed fixed window noted. Page 14 of 45

Kitchen The kitchen is used for food preparation and often for entertainment. Kitchens typically include a stove, dishwasher, sink and other appliances. 1. Dishwasher Damage noted at start button 2. Doors 3. Garbage Disposal The unit makes irregular noise. This may be a foreign object stuck in the disposal. 4. Microwave Page 15 of 45

5. Cook top condition 6. Oven & Range Gas cook top noted. Upper oven temperature measured 325 at the 350 degree setting. Lower oven tested at 330 at the 350 degree setting. 7. Sinks 8. Drinking Fountain 9. Spray Wand The drinking fountain was operated and was functional. The spray wand was operated and was functional. Page 16 of 45

10. Trash Compactor 11. Vent Condition 12. Window Condition Materials: Wood framed single hung window noted. 13. Floor Condition Materials: Hardwood flooring is noted. 14. Plumbing 15. Ceiling Condition Materials: There are drywall ceilings noted. 16. Electrical 17. GFCI GFCI, lights & fans on same circuit. GFCI did not respond to test at south side, suggest replacing for safety. Page 17 of 45

18. Wall Condition Materials: Drywall walls noted. Walls are clad in ceramic tile. There are areas still under construction. These areas are not tested. Some grout was deteriorated in area of dishwasher Page 18 of 45

1. Locations 2. Dryer Vent Locations: Northeast hall Laundry 3. Electrical 4. GFCI No GFCI protection present, suggest installing GFCI protected receptacles for safety. 5. Exhaust Fan 6. Gas Valves 7. Wash Basin 8. Floor Condition Materials: Ceramic tile is noted. Page 19 of 45

9. Plumbing 10. Wall Condition 11. Ceiling Condition 12. Doors Materials: Drywall walls noted. Materials: There are drywall ceilings noted. No major system safety or function concerns noted at time of inspection. 13. Window Condition Materials: Wood framed double hung window noted. Page 20 of 45

Heat/AC The heating, ventilation, and air conditioning and cooling system (often referred to as HVAC) is the climate control system for the structure. The goal of these systems is to keep the occupants at a comfortable level while maintaining indoor air quality, ventilation while keeping maintenance costs at a minimum. The HVAC system is usually powered by electricity and natural gas, but can also be powered by other sources such as butane, oil, propane, solar panels, or wood. The inspector will usually test the heating and air conditioner using the thermostat or other controls. For a more thorough investigation of the system please contact a licensed HVAC service person. 1. Equipment Description Materials: Home was equipped with a 3 1/2 ton gas/electric package HVAC unit, manufactured in 1999. Home was equipped with 3 1/2 ton electric condenser/gas furnace split unit, manufactured in 2013. Home was equipped with a 2 ton gas/electric package HVAC unit, manufactured in 2007. Typical rated lifespan for these type units is 12-15 years. 1999 unit is well past its rated lifespan. Inspector recommends further evaluation of this unit by an HVAC contractor. Page 21 of 45

2. Heater Condition Materials: Gas fired forced hot air. The home has a split system. The home has a dual pack unit. 3. Heater Base 4. Enclosure Plenum for the main package unit needed to be attached and sealed to the exterior wall. 5. Venting Vent on the 1999 package unit was heavily corroded. Page 22 of 45

6. Gas Valves Gas line to the furnace was corroded. Line should be over sprayed to prevent further corrosion and eventual leaks from forming. 7. Refrigerant Lines 8. AC Compress Condition Compressor Type: Electric Location: The compressor is located on the exterior grounds. Appeared functional at the time of inspection. Cooling unit could not be tested as the external temperature was below 60 degrees. The insulation is missing or damaged at exterior refrigerant line. 9. Air Supply Page 23 of 45

10. Registers 11. Filters 12. Thermostats Page 24 of 45

1. Base 2. Heater Enclosure Water Heater The water heater base is functional. The water heater enclosure is functional. 3. Combusion 4. Venting 5. Water Heater Condition Heater Type: Gas Location: The heater is located in the attic. Modern standards would require an expansion tank be installed. 6. TPRV 7. Number Of Gallons 50 gallons Page 25 of 45

8. Gas Valve 9. Plumbing 10. Overflow Condition Page 26 of 45

1. Roof Condition Garage Materials: Roofing is the same as main structure. Materials: Asphalt shingles noted. 2. Walls 3. Anchor Bolts 4. Floor Condition The anchor bolts were not visible. Materials: Bare concrete floors noted. 5. Rafters & Ceiling 6. Electrical 7. GFCI 8. 240 Volt No GFCI protection present, suggest installing GFCI protected receptacles for safety. 9. Exterior Door 10. Fire Door 11. Garage Door Condition Page 27 of 45

12. Garage Door Parts 13. Garage Opener Status Chain drive opener noted. 14. Garage Door's Reverse Status 15. Ventilation 16. Vent Screens Under eave soffit inlet vents noted. Ridge exhaust venting noted. Gable louver vents noted. 17. Wash Basin Page 28 of 45

1. Electrical Panel Electrical Location: Main Location: Main Disconnect in panel box. Location: Sub Panel Location: Located in the garage. 2. Main Amp Breaker 225 amp 3. Breakers in off position 4. Cable Feeds There is an underground service lateral noted. Page 29 of 45

5. Breakers Materials: Copper non-metallic sheathed cable noted. 6. Fuses Page 30 of 45

1. Roof Condition Roof Materials: Inspected from ground level with binoculars. Materials: Asphalt shingles noted. 2. Flashing 3. Chimney 4. Vent Caps 5. Gutter Page 31 of 45

1. Access Attic Upstairs Hall. No Visible Access to upper portion of attic. 2. Structure Moisture stains at flooring in area of furnace tested damp at time of inspection. 3. Ventilation 4. Vent Screens Under eave soffit inlet vents noted. Ridge exhaust venting noted. Gable louver vents noted. Page 32 of 45

5. Duct Work 6. Electrical Missing smoke detector 7. Attic Plumbing 8. Insulation Condition 9. Chimney Materials: Fiberglass batts with kraft paper facing noted. 10. Exhaust Vent Could not access. Page 33 of 45

1. Doors Exterior Areas Left side casing at the front entry door was decayed at the base. 2. Window Condition All window screens were missing. Page 34 of 45

3. Siding Condition Gas and a/c line penetrations of the exterior wall should be sealed to prevent moisture intrusion. Page 35 of 45

4. Eaves & Facia Aluminum trim piece at the east peak was bent away from the fascia. Page 36 of 45

Grounds 1. Driveway and Walkway Condition Materials: Concrete sidewalk noted. Asphalt driveway noted. 2. Grading 3. Vegetation Observations Prune or remove any plants that are in contact or proximity to home to eliminate pathways of wood destroying insects. 4. Gate Condition 5. Patio and Porch Deck 6. Stairs & Handrail 7. Grounds Electrical Left side back patio light fixture was not functioning. Southwest corner security lights were not functioning. Page 37 of 45

8. GFCI GFCI at the back patio wall would not trip and should be replaced. 9. Main Gas Valve Condition Materials: South side. Page 38 of 45

10. Plumbing 11. Water Pressure High pressure. 85 Normal range for residential is 45-75. 12. Pressure Regulator We recommend the installation of a pressure regulator. 13. Exterior Faucet Condition Location: North side of house. South side of house. Page 39 of 45

14. Balcony 15. Patio Enclosure 16. Patio and Porch Condition 17. Fence Condition 18. Sprinklers Page 40 of 45

1. Crawlspace Crawlspace Loose wood and cardboard should be removed from the crawlspace to prevent termite infestation. Open junction boxes were noted in southeastern and northeastern crawl Moisture barrier was missing from some areas of the crawlspace. Dryer vent was pinched closed in the area of the laundry room floor joists. This will prevent adequate propulsion of lint and humidifier air. Page 41 of 45

2. Walls 3. Insulation 4. Plumbing Evidence of leakage detected in area of laundry room and master bathroom and requires review and repair by a qualified contractor. Page 42 of 45

5. Access Access was located on the south side of the home. 6. Drainage 7. Framing Improper cutting/over notching of floor joist noted in area of laundry room in northeast crawl. Recommend review and repair by a qualified contractor. 8. Subfloor 9. Piers Some moisture intrusion in area of laundry and master bath Page 43 of 45

10. Ductwork 11. Ventilation 12. Vent Screens Page 44 of 45

Glossary Term A/C Expansion Tank GFCI Definition Glossary Abbreviation for air conditioner and air conditioning An expansion tank or expansion vessel is a small tank used to protect closed (not open to atmospheric pressure) water heating systems and domestic hot water systems from excessive pressure. The tank is partially filled with air, whose compressibility cushions shock caused by water hammer and absorbs excess water pressure caused by thermal expansion. A special device that is intended for the protection of personnel by de-energizing a circuit, capable of opening the circuit when even a small amount of current is flowing through the grounding system. Page 45 of 45