PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

Similar documents
PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Twin Photobeam Detectors Manual

CAUTIONS ON INSTALLATION

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

AX-70TN, AX-130TN, AX-200TN AX-100TF, AX-200TF

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

1 PRODUCT COMPONENTS This section describes the contents of the product package and the names and functions of

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

PHOTOELECTRIC BEAM SENSOR PB- 50HFA-KH PB-100HFA-KH PB-200HFA-KH

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.

ITALIANO BST-100 ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH 2 BEAMS OF PROTECTION INSTALLATION MANUAL. Manuale istruzioni BST-100. Pag.

Quadruple-beam photoelectric detector

Installation And commissioning manual. Series S Double Beam 1/16

4-Row Active Infrared Presence Detector for Automatic Door Control. Cover

English. Series. Installation and Use Manual

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

Active Infrared Multi Beam Sensors

Active Infrared Multi Beam Sensors. R Series

Long-Range Barrier Sensors

perimeter barriers Active infrared SAFET Y INSIDE AND OUTSIDE THE HOME WALL-FLUSH INTERNAL OR EXTERNAL PROTECTION EXTERNAL PROTECTION

Beam Sensor 100 Mtr Manual Wired Type & Convertible to Wireless Type Model: BS- Series Outdoor Use

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

INDEX. Installation recommendation

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

INFRARED MODULATED BARRIERS

Movement Detector GJD 300

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

Photoelectric Beam Detector

Safety Photo Beam UL MONITORED DEVICE

PHOTOELECTRIC BEAM SENSOR

Solar Powered Wireless Photobeam Sensors

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Reflective Beam Smoke Detector

/ / 2018

Description. Optex Incorporated

CONFIGURATION OF THE OPTICALS

PARVIS Safe and tranquil thanks to Parvis

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

DUAL OPTIC. Installation manual

COMBINATION SENSOR. COM-50XTL : OUTDOOR 165ft (50m) Instruction Manual

INSTALLATION AND MAINTENANCE INSTRUCTIONS NFXI-BEAM AND NFXI-BEAM-T REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

INDEX. Installation recommendation

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500 AND 6500S REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

Installation Instructions

Infrared Single Light Barrier. Mounting Instructions DO560

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

Installation and Operation Manual

other ambient light sources. Before installation, make sure to read this instruction manual carefully for safe and effective product operation.

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Radio Frequency Do s & Don ts

INDICE. Installation recommendation

Instruction manual for the Infrared Point Type Flame Detector

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Laser Distance Sensor Type M Analog-Output

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors

REDNET INFRARED BEAM SET TYPE RN4/10-25, RN4/25-75 & RN4/ INSTALLATION AND SET UP INSTRUCTIONS

Series PHOTOSWITCH Photoelectric Sensors. Standard and Timing. Description. Supplied Accessories

D-Tect 2 GJD300 Quad PIR Movement Detector

ALK-V PHOTOELECTRIC SMOKE SENSOR

Motion Detector. Installation and Usage Guide. Need help? Visit protectamerica.com/chat

FSLIMPRO

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

English. Italiano. Português. Françias. Español

INDEX. Installation recommendation

Installation Instructions

Wireless PIR Sensor with Transmitting Distance:300~500m

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

FAAST. Fire Alarm Aspirating Sensing Technology

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

M15-GSL12P30 M15-GSL12P30S Heat Spy Infrared Thermometer User Manual

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

HX-80NRAM. High Mount Outdoor Detector

Motorised Infrared Optical Beam Smoke Detector. User Guide

Reliable Detection of Transparent Objects

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

Auer - Signal tower ECO Ø70 mm modular

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

VX-402, VX-402REC CONTENTS FEATURES

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

Retro-reflective Sensing range: 0mm to 2000mm

Motorised Infrared Optical Beam Smoke Detector. User Guide

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Remote Chexit Module (RCM) System. General Information

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor

DS160/161 Request To Exit PIR sensors Installation Instructions

Transcription:

PHOTOELECTRIC DUAL BEAM DETECTOR Manual R4222 RECEIVER INDICATORS 1 PARTS GOOD LEVEL ALARM COVER Connection s Indicators Wiring Knockout Response Time Adjustment (only for receiver) Signal Level Test Points Tamper Sight Hole GOOD LED (green). Use when adjusting beam alignment. ON when beams are aligned, OFF when beams are not aligned. (Refer to operation instructions) LEVEL LED (red). ON indicates received signal. Brightness varies, depending on incident level. ALARM LED (red). ON indicates beam blocked. Use when setting response time. (Refer to operation instructions) Vertical Alignment Screw Horizontal Angle Adjusting Bracket TRANSMITTER INDICATOR Lens Cover Locking Screw POWER INTERNAL VIEW OF RECEIVER POWER LED (green). ON when light beam is transmitting. 2 MOUNTING CAUTIONS Do not mount the detector in the following conditions: Where obstructions (plants, fences, etc.) are between the receiver and the sender. Where the mounting surface is unstable. Where sunlight and headlights shine directly into the front of the receiver. Mounting Height Sensing Area Spread of Beam Beam Alignment Range Horizontally 180 Up / Down Direction 20 (±10 ) The optical axis can be adjusted within horizontal direction ±90, vertical direction ±12. When using more than one set make sure to alternate the transmitters and detectors as above.

3 MOUNTING 1. Loosen the coverholding screw and remove the outer cover. MOUNTING AND CONNECTIONS 2. Remove the rubber knockout and use the screw holes to mount the unit. 3. Remove the rubber knock-out and pull the wire through. 4. Mount the detector on the wall. Wiring Hole BACK COVER 5. Connecting wires to the terminals Wiring Pattern Power Free Tamper Switch 1 2 3 4 5 6 7 Alarm Output with 22awg minimum 300 ft (91.4m) max length Be sure to capture the wire ends under the wire clamp plates. Avoid frayed ends on wires that might produce a short circuit. Power Tamper Switch Wiring Pattern 1 2 3 4 5 6 7 Correct Wrong Wrong Pole Mounting 1. Break out the wire hole on the bracket then pull out the wires. 2. Remove the cover. 3. Fix the base plate on the bracket. Back to back installation (Refer to the fi gure below.) Panel Fixed Regular Ring diameter of the bracket

4 CONNECTING C PHOTO BEAMS TO GTO CONTROL BOARDS Mighty Mule Control Board STALL FORCE Make sure the power switch to the opener is turned off before connecting safety device wiring to the terminal blocks. Unplugging the transformer does not turn power to the opener OFF. MIN MAX Non-Contact Sensor Connection: Connect one of the non-contact sensor dry contact output wires to the MON () terminal and the other to the SAFETY terminal on the Mighty Mule or the GTO/PRO control board. CYCLE SAFETY EXIT/ SHADOW LOOP GRN BLK RED RECEIVER GTO/PRO Control Board STALL FORCE MIN MAX from Non-Contact Sensor (photo beam) J11 J8 J12 CYCLE SAFETY EXIT SHADOW LOOP GRN BLK RED RECEIVER from Non-Contact Sensor (photo beam)

5 BEAM ALIGNMENT 1. Remove the cover and turn ON power. Viewfi nder 2. Observe the aiming effect of the aiming lens at 4in (10cm) on the right. 4in (10cm) 3. Adjust the horizontal pivot, and the vertical adjustment screw using the built-in viewer. Look through the peep hole on either side and adjust to put the oppposite sensor in the middle of the cross-hairs in the viewfi nder. The GOOD indication lamp should be on. (Adjust the light axis continuously if the indication lamp is not on.) Vertical Adjustment Screw To Raise To Lower The brighter the red LEVEL indicator light, the higher the precision of the light axis. Horizontal adjusting bracket The best method of adjusting the optical axis is to measure the signal level at the test probe points. 1. Insert the DMM probes into the test points on the side of the receiver. 2. Adjust the horizontal angle and vertical angle until the voltage is at maximum. Voltmeter or DMM 3. If 1.2v or above voltage cannot be reached, the transmitter and/or receiver should be readjusted. 6 BEAM INTERRUPTION TIME ADJUSTMENT 2 3 4 1 5 Response Time Adjustment 1 2 3 4 Fast running 20ft/s (6.9m/s) Fast walking with quick steps 4ft/s (1.2m/s) Normal walking 2.5ft/s (0.7m/s) Slow action less than 2ft/s (0.3-0.5m/s)

7 After installation, confi rm correct 8 VERIFY CORRECT OPERATION ns operation by suitable walking tests. Refer to the appropriate LED indicator during the walking test. Condition Indication Transmitting Green LED is ON TROUBLESHOOTING Beam Clear Beam ed GOOD-LEVEL Indication Alarm indication lamp is ON Symptom Possible Cause Remedy LED does not light. Improper voltage supplied. Check the power supply and wiring. LED does not light. Improper voltage supplied. Check the power supply and wiring. Alarm LED does not light, even when beams are blocked. When the beams are blocked, the receiver LED light is ON, but not alarm. The alarm indication lamp of receiver is always on. 1. Beams refl ect to the receiver by other objects. 2. Both beams are not blocked simultaneously. 3. Beam block time is too short. 1. Wiring is short circuited. 2. Wiring connection is not good. 1. Optical axis is not properly adjusted. 2. There are obstructions between the transmitter and the receiver. 3. The outer covers are dirty. 1. Remove the refl ecting object or change optical axis direction. 2. both beams. 3. Increase beam block time. Check wiring and connection spot. 1. Adjust the optical axis. 2. Remove the obstructions. 3. Clean with window cleaner and a soft cloth. Intermittent Alarm 1. Bad wiring. 2. Fluctuating power supply / voltage. 3. Intermittent blockage between the transmitter and the receiver. 4. The receiver or transmitter is unstable. 5. ed by other moving objects. 1. Check wiring. 2. Check the power supply. 3. Remove the obstruction or relocate. 4. Fix the mounting. 5. Adjust the optical axis. 6. Adjust interruption time or change installation position. SPECIFICATIONS Model R4222 Detection Method Infrared photoelectric Range Outdoor 98.4 ft (30m) Indoor 295.2 ft (90m) Beam Characteristics Pulsed infrared dual beams Response Time 50~700msec (selectable) Power Input DC13.8~24V / AC11~18V Current Consumption 40mA max Output Pulse Duration 2Sec (±1)nominal Alarm Output Form C relay (AC/DC 30V 0.5A max) Tamper Switch N.C. Opens when cover is removed (receiver only) Operating Temperature -13 F (-25 C)~131 F (55 C) Environment Humidity 95% max Alignment Angle ±5 vertical, ±90 horizontal Mounting Wall or pole Weight.66lbs (300g) Both transmitter and receiver Appearance PC Resin (Black)