The guarantee on this appliance is valid for 12 months from the first day of installation.

Similar documents
TABLE OF CONTENTS. IMPORTANT Please read this manual carefully.

End User Manual ACO 35 MFFI COMBI

SERIES. End User Manual ACO 27 MFFI G.C.N: ACO 32 MFFI G.C.N: ACO 27 RFFI G.C.N: ACO 32 RFFI G.C.

E-COMBI EVO E-SYSTEM EVO

24/30/38. E-Combi. CONDENSING WALL HUNG COMBINATION BOILER G.C.N : (24 kw) G.C.N : (30 kw) G.C.N : (38 kw)

Supplied by HeatingSpares247.com

A/23 MFFI - A/27 MFFI

USERS GUIDE 24, 30. For installation guide see reverse of book

USER GUIDE VOGUE MAX SYSTEM

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

iheat 25c iheat 30c iheat 35c

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

USERS GUIDE. LOGIC+ Combi 24, 30, 35

Installation Instructions Type C Boilers G.C.N:

Installation Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS WITH THE END-USER

User's Instructions. Alpha CB50

E-Combi One E-System ONE

Logic+ Combi

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

USER GUIDE LOGIC HEAT H

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

Baxi Maxflow Combi WM

Baxi Maxflow Combi FS

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

AquaNova. Water heater. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

GB24 & GB30. User Manual

MURELLE EV HE 25/55-30/55

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Open Vented Condensing Boilers

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

MERIDIAN HE 30 C. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Mikrofill Ethos Condensing combination boiler

INSTRUCTION FOR THE USER THC V E OIL BLU

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

Operating instructions

Operating instructions

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

User Manual for model

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler


Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

GENUS HE GENUS HE 24 GENUS HE 30 GENUS HE 38. User Manual. Condensing wall hung system boiler

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

Installation Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

Operating instructions

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

WHE 2.24 / WHE 2.24 FF

VIESMANN. Operating instructions VITODENS 100-W. for the system user

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C

USERS MANUAL FOR GAS BOILERS

Combi Eco Elite Range. User s Guide and Important Warranty Information

2 Minimiser SE - User's

MAINTENANCE AND SERVICE GUIDE

INSTALLATION AND MANINTENANCE INSTRUCTIONS

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

DOMESTIC HOT WATER Follow operational sequence

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

5 On/Off button 6 Function selector switch 7 Symbol - Eco function 8 Symbol - Standard heating function

VIESMANN. Operating instructions VITODENS 111-W. for the system user

24CDi, 28CDi & 35CDi II COMBI

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Planet Super4F.S. User Instructions

Osprey 2 CFL

Operating instructions

MICROGENUS HE WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILER. minimum space HIGH EFFICIENCY

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

Installation Instructions Type C Boilers G.C.N:

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

SPECIFICATIONS - NIKE

ACCUMULATION OF EUROPEAN CLASS

USER MANUAL ACQUAHOME 32 B BLU

Gas Instantaneous Water Heater

Transcription:

Users Manual

Dear Customer, Thank you for choosing an ARISTON boiler. We guarantee that your boiler is a reliable and technically sound product. This Users Manual provides detailed instructions and recommendations for proper installation, use and maintenance. Remember to keep this manual in a safe place for future reference i.e. by the gas meter. Your local MTS Servicing Centre is at your complete disposal for all requirements. The guarantee on this appliance is valid for 12 months from the first day of installation. Repairs to the electric, hydraulic or gas circuits may be carried out only by your local authorised MTS Servicing Centre. Every attempt has been made to avoid errors of any kind in this Users Manual, the Management invites customers to inform of any inaccuracies which they may find. This will help to improve our service 2

TABLE OF CONTENTS 1. GENERAL INFORMATION page 4 Technical Information page 5 Control Panel page 6 2. OPERATING INSTRUCTIONS page 8 3. USEFUL INFORMATION AND TROUBLESHOOTING page 12 4. MAINTENANCE page 15 5. CHANGE OF GAS TYPE page 15 6. TIME CLOCK page 15 IMPORTANT! Please read this manual carefully. For additional information, please consult the Installation and Servicing Instructions. Make sure to keep the manuals provided with the appliance so that they can be used by the end-user, installer or our authorised engineer. 3

1. GENERAL INFORMATION MTS (GB) Limited support the initiative. Your installer will give you, and show you how to use, a logbook which will give you important information about your boiler, and heating system. Please have this logbook to hand whenever you contact a service engineer or us. All CORGI Registered Installers carry a CORGI ID card, and have a registration number. Both should be recorded in your boiler Logbook. You can check your installer is CORGI registered by calling CORGI direct on :- (01256) 372300. This is a combined appliance for the production of central heating (C.H.) and domestic hot water (D.H.W.). This appliance must be used only for the purpose for which it is designed. The manufacturer declines all liability for damage caused by improper or negligent 4 use. Do not allow children or inexperienced persons to use the appliance without supervision. If you smell gas in the room, do not turn on light switches, use the telephone or any other object which might cause sparks. Open doors and windows immediately to ventilate the room. Shut the gas mains tap (on the gas meter) or the valve of the gas cylinder and call your Gas Supplier immediately. If you are going away for a long period of time, remember to shut the mains gas tap or the gas cylinder valve. Before any intervention within the boiler it is first necessary to cut off the electrical power supply by turning the external switch to OFF. This manual may be kept in the front panel of the boiler.

TECHNICAL INFORMATION GENERAL DATA Heating input max-min Heating output max-min Efficiency at Maximum Thermal Capacity (see installation instructions) CENTRAL HEATING Operating Temperature max-min Maximum-Minimum Heating Pressure Built-in expansion vessel - Total capacity DOMESTIC HOT WATER Maximum-Minimum Temperature of Water for Domestic Use Working pressure max-min Flow rate T 35 C Flow rate T 35 C Minimum flow rate ELECTRICAL DATA Electrical Supply/ Frequency Power Consumption Protection of Electrical System CATEGORY Nominal Pressure/Methane Gas (G20) Nominal Pressure/Liquid Gas (G30-G31) kw kw % C bar litres C bar l/min gal/min l/min V/Hz W IP mbar mbar 23 kw 25.6-11.0 23.7-9.6 92.5 82-42 3-0.7 6 54-36 8-0.2 9.7 2.2 2.5 230/50 135 X4D 20-25 30-37 5

CONTROL PANEL FR019A 6 23 MFFI

LEGEND: A - On/Off button B - Central heating temperature adjustment C - Domestic hot water temperature adjustment D - Heating system pressure gauge E - Time clock F - Central heating selector G - Central heating L.E.D. (green) H - Fume sensor L.E.D. (yellow) I - Overheat and/or ignition failure (lockout) L.E.D. (red) J - Ignition failure (lockout) and/or overheat reset button K - ON/OFF L.E.D. (green) 7

2. OPERATING INSTRUCTIONS CAUTION Installation, start-up, adjustments and maintenance must be performed by a competent person only, in accordance with the current Gas Safety (Installation & Use) Regulations and the instructions provided. Improper installation may cause damage or injury to individuals, animals and personal property, for which the manufacturer will not be held liable. To ensure efficient and safe operation it is recommended that the boiler is serviced annually by a competent person. If it is known or suspected that a fault exists on the appliance, it must not be used until the fault has been corrected by a competent person. 8 HELPFUL SUGGESTIONS To get the most out of your boiler, we have provided you with some useful advice on proper use and maintenance: - Periodically check the system pressure using the pressure gauge D, make sure that the pressure is at 1.5 bar when the system is off and cool. If the pressure is below the minimum recommended value. Consult your installer for checking and refilling the system. D UT013Af

- The outer panels of the units case must only be cleaned with a damp cloth. Do not use abrasive cleaners. The control panel can be wiped with either a damp or dry cloth. Spray polishes must not be used on the control panel surface or knobs. Care must be taken in preventing any liquid entering the appliance. PRACTICAL TIPS - If the water is very hard, it is recommended that a water softener be added to the system so as to reduce the formation of limescale in the heat exchanger. This will ensure that the efficiency of the unit remains the same over time, reducing gas consumption and maintenance costs. - If the boiler should be out of use for a prolonged period, it is recommended that the electrical power supply be disconnected and that the external gas cock be closed. If low temperatures are expected, the boiler and system pipe work should be drained in order to prevent frost damage. - To improve comfort and take full advantage of the heat produced by the boiler, it is recommended that an external (room) thermostat be installed. - It is good practice to clean and service the appliance and central heating system every year. Call an Authorised Service Centre. 9

IGNITION PROCEDURE Press button A. The green L.E.D. K will illuminate indicating that the boiler K is ready to operate. The centralised electronic control unit will ignite the burner, without any A manual intervention but in response to the UT002A request for domestic hot water or heating. If, after approximately 10 seconds, the burner has not ignited, the boiler safety devices will shut off the gas and the red L.E.D. I illuminates. To reset J the ignition system, the reset J must be pressed and released. Should the boiler fail to ignite a second time, 10 I UT006A check that the external gas cock is open. If the problem persists, contact an Authorised Service Centre. WINTER AND SUMMER OPERATING MODES In the winter operating mode, the boiler will produce both central heating and domestic hot water. In the summer operating mode, the boiler will produce only domestic hot water. Press F button to select winter mode. The green L.E.D. G will illuminate. G F UT003A

ADJUSTING THE HEATING It is possible to set the temperature of the heating system by adjusting the knob B. By positioning the B indicator somewhere between 1 and 9, a temperature may be obtained which varies from approximately UT004A 40 C to about 80 C. EXTERNAL (ROOM) THERMOSTAT CONTROL If an external (room) thermostat is installed, it is recommended that the temperature of the heating system be set by means of the B knob, leaving it at 7-8 position in order to obtain the best performance from the boiler and to allow the regulation of the external temperature to function efficiently. SETTING THE HOT WATER FOR DOMESTIC USE Both in the winter and summer mode, the temperature of the domestic hot water may be adjusted by using the C knob. A delivery temperature for the C water may be chosen in a range from 36 C to about 56 C, depending on the flow rate of the water and the position UT005A of the knob between 1 and 9 settings. 11

TURNING OFF CENTRAL HEATING To turn off the central heating, press the F button; the respective green L.E.D. G will go off. The boiler will stay in summer mode, only providing domestic water on request. TURNING OFF THE BOILER To turn the boiler off, press the button A ; the respective green L.E.D. K will go off. Close the gas cock located under the boiler and turn the K electricity supply switch (located outside the boiler) to the OFF A position. 12 G F UT003A UT002A 3. USEFUL INFORMATION AND TROUBLESHOOTING BOILER SHUTDOWN SITUATIONS The boiler is equipped with safety devices that intervene in certain situations and shut it off. Most of these situations are communicated by means of the L.E.D.s and at times the user may be able to remedy them. SHUTDOWN DUE TO IGNITION FAILURE In the event that the automatic ignition of the burner has failed, the red L.E.D. I will illuminate. In order to reset the ignition, the button J must be pressed and released. Should the boiler fail to ignite a second time, check

that the external gas cock is open. If the problem persists, contact an Authorised Service Centre. SHUTDOWN DUE TO OVERHEATING In the event that the safety limit is exceeded for the temperature of the water in the boilers exchanger, the thermostat shuts off the boiler and the red L.E.D. J I illuminates. To remedy this situation, wait a few minutes to allow the exchanger to I cool down, then press and release the reset UT006A J I UT006A button J. If this situation occurs frequently, contact an Authorised Service Centre. SHUTDOWN DUE TO INSUFFICIENT WATER CIRCULATION If the boiler is off, one possible cause for this state is an insufficient pressure of water in the system. Check the system pressure on the pressure gauge D and if it is less than 0.5 bar, consult your installer for checking and refilling the system. If the boiler does not start up again, contact an Authorised Service Centre. If there are frequent drops in pressure within the system, have a plumber D UT001A 13

check the heating system for possible water leaks. TEMPORARY SHUTDOWN DUE TO DEFECTIVE DISCHARGE OF EXHAUST FUMES The boiler is fitted with safety devices, which in the event of a defective discharge of exhaust fumes, automatically interrupts the gas supply, thereby shutting off the boiler. The shut-off of the boiler is temporary and is indicated by the illumination of the yellow L.E.D. H for a period of about 15 minutes. Once this time period has passed and the H discharge state of exhaust fumes has returned to normal, the UT006A 14 boiler automatically turns back on. IMPORTANT! If this situation occurs frequently, contact an Authorised Service Centre. so that they may check that the exhaust fumes are being expelled correctly and that the area is ventilated properly. ANTI-FROST DEVICE If the water temperature goes below 3 C, the burner turns on at minimum power in CH mode until the water in the boiler has reached a temperature of about 33 C. This function is only activated when the boiler is operating perfectly and - the system pressure is sufficient; - the boiler is powered electrically; - gas is being distributed.

4. MAINTENANCE 6. TIME CLOCK Schedule an annual maintenance check-up for the boiler with a competent person. Correct maintenance always results in savings in the cost of running the system. 5. CHANGE OF GAS TYPE Our boilers are designed to function either with Natural Gas (methane) or LPG gas. If you need to changeover from one gas to the other, one of our Authorised Service Centres should be contacted. UT011Ap NOTE: the time clock is for central heating control only. The time clock is provided with 96 switches, called riders, each of which covers a time interval of 15 minutes (four per hour). When a rider is switched from the inside (off setting) to the outside of the 15

clock border (on setting), the circuit is closed (switch on) for a period of 15 minutes and then the boiler starts if the room thermostat (if installed) or the heating thermostat require heat (heating function on). EXAMPLE To set the heating of your home in the time interval from 7.00 am to 9.30 am and from 7.00 pm to 10.00 pm every day: - rotate the outer ring of the clock in a clockwise direction until the correct time of day (24h) lines up with the arrow on the clock (at approx. 2 o clock position); - under no circumstances should the minute hand be moved manually; - make sure all the switches, i.e. the riders, are placed on the inside of the clock border; 16 - pull outward the riders for 7.00 am and 9.30 am, and then all riders between these two; - repeat this for 7.00 pm and 10.00 pm. Other heating intervals may be set in the same way. The timer has approximately 150 hours of battery back up for power failure. The clock is provided with a selector switch with three positions (see figure): 1. Position I CONSTANT: in this position, the clock circuit is always closed (switch on), therefore the boiler will constantly be on and will only shut off upon the UT014A

request of the room thermostat (if installed) or the heating thermostat; 2. Position O HEATING OFF: in this position, the clock circuit is always open (switch off) and the boiler will therefore never ignite for heating; UT014A TECHNICAL DATA Ambient temperature: - 10 C to + 55 C Running reserve: 150 h (not for 1.5 V DC) Shortest switching time: 15 minutes Programmable: Every 15 minutes 3. Central Position PROGRAMMING ACTIVE: in this position, the programming set by the user is active. UT014A 17

18

19

Manufacturer: Commercial subsidiary: Merloni TermoSanitari SpA - Italy MTS (GB) LIMITED MTS Building Hughenden Avenue High Wycombe Bucks HP13 5FT Telephone: (01494) 755600 Fax: (01494) 459775 Internet: http://www.mtsgb.ltd.uk E-mail: info@mtsgb.ltd.uk Technical Service Hot Line: (01494) 539579 Cod. 2399841567000 Stampa: Bieffe Recanati