bring value to your space

Similar documents
GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

AUGUST, High-Efficiency Condensing Gas-Fired Separated Combustion Unit Heaters

SUBMITTAL SCHEDULE & DATA

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

Gas-Fired Unit Heaters Commercial & Industrial

Gas-Fired Unit Heaters Commercial & Industrial

Gas-Fired Indoor and Outdoor Duct Furnaces

HVAC HEATING PRODUCTS

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

FEATURES AND BENEFITS

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

Gas-Fired Indoor Duct Furnace Gravity and Power Vented

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

Gas-Fired Heating Equipment

Gas-Fired Indoor and Outdoor Duct Furnaces

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

HVAC HEATING PRODUCTS

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

GQVC-12 HVAC EQUIPMENT. GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces.

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS

TECHNICAL SPECIFICATIONS

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

Work In Shirt-Sleeve Comfort When It s Doggone Cold

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

KIC Air Curtains. Technical Guide

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

GA Gas Unit Heater Assemblies Technical Guide

HVAC HEATING PRODUCTS Application Manual

SKYPAK II Heating & Cooling Self Contained Packages

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

STEAM/HOT WATER UNIT HEATERS

Ruud Acheiver Series Upflow Gas Furnaces

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

G6RC Series TECHNICAL SPECIFICATIONS

CATALOG: HVAC - Gas Space Unit Heating

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

GARAGE / WORKSHOP INFRARED HEATERS

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

8+* Bulletin No November 1997

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

SKYPAK II, 3 Ton Series, gives you a

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

COMMERCIAL & INDUSTRIAL UNITARY HEATING PRODUCTS GAS STEAM/HOT WATER OIL ELECTRIC

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

U n i t H e at e r s

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

True performance and rugged durability. TU, LF and LD Models

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

RG7D 1-Stage Heat Series

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

Direct Fired Heater Model AD Specification

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

24 VAC SYSTEM CONTROL KIT

G34M Bulletin #69/ August 2003

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

REPLACEMENT PARTS LIST

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS

SKYPAK II, 3 Ton Series, gives you a

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

TECHNICAL SPECIFICATIONS

LARGE CAPACITY HEATERS

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

Upflow/Horizontal Condensing, Gas-Fired Furnace

80% A.F.U.E. DOWNFLOW GAS FURNACES

Transcription:

PTP unit heaters can use natural or propane gas, and are available in single-stage or optional two-stage controls. bring value to your space with THE NEW PTP HEATER. Introducing the new power vented, PTP unit heater line with stainless steel bent tube heat exchanger standard. The PTP was specifically designed with the customer in mind to provide high value at a reasonable cost. Backed by Modine s nearly 100 years of pioneering HVAC innovation, the horizontal mounted PTP delivers reliable performance and longer life in a small-business-friendly package. Propeller Unit Model PTP General Performance Data Model PTP Sizes 150 175 200 250 300 350 400 BTU/Hr Input 1 150,000 175,000 200,000 250,000 300,000 350,000 400,000 BTU/Hr Output 1 120,000 140,000 160,000 200,000 240,000 280,000 320,000 Max. Mounting Height (Ft.) 2 15 14 15 18 19 18 21 Heat Throw (Ft.) (@ Max Mtg Ht) 2 51 50 53 62 69 65 74 1 Ratings shown are for elevations up to 2,000 ft. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. (In Canada see rating plate.) Reduction of ratings requires use of a high altitude kit. 2 Data taken at 55 F air temperature rise. At 65 F ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit, and without deflector hoods. benefits of the ptp line include: Stainless steel heat exchanger comes STANDARD on all units, extending the life of your investment 10-year heat exchanger warranty is STANDARD, providing you peace of mind Totally enclosed, permanentlylubricated fan motor outside the cabinet is standard for trouble-free dependability Constructed with Modine s proven tubular heat exchangers for a low-profile design on jobs with lower mounting heights Optional finger-proof fan guard for low mounting height applications Power exhauster and controls mounted inside the cabinet for protection from airborne moisture and dust Installs quickly and easily with knockouts and field gas and wiring connections inside a roomy controls section for quick and easy access Proudly Made in the USA To learn more visit www.modinehvac.com or call 1.800.828.HEAT Follow us on Twitter @ModineHVAC RAISE YOUR COMFORT LEVEL 2012 Modine Manufacturing Co. 6-122

DESIGN FEATURES - MODELS PTP Figure 6.1 - Factory Mounted Standard and Optional Features (Model PTP) 6 8 10 1 9 2 5 4 3 7 8 ➀ Power Exhauster (STD) All PTP series unit heaters are supplied with a round vent pipe connection. ➁ Pressure Switch (STD) An automatic reset vent pressure switch is supplied on all PTP series unit heaters and is designed to prevent operation of the main burner in the event there is restricted venting of flue products. This restriction may occur due to an improper vent diameter, long vent runs, unapproved vent terminal, high winds, high negative pressure within space, etc. After the cause of the restriction has been corrected, the pressure switch will reset automatically. See the trouble shooting section of the installation and service manual for more information. ➂ Integrated Direct Spark Control Board (STD) The integrated direct spark ignition control combines all furnace control functions. The integrated board provides digital control of the air mover, inducer, ignition, gas valve and flame sense as well as monitoring the safety circuit at all times. The board includes LED diagnostics for trouble shooting and a fused power supply. ➃ Gas Valve - (See Table 14.2) a) Single Stage Gas Valve - (STD) The main gas valve is factory installed on the unit heater gas train. The main gas valve provides regulator, main gas, and manual shutoff functions. The valve is redundant and provides 100% shut off. b) Two Stage Gas Valve - (OPT) The two-stage gas valve is factory installed on the unit heater gas train. The two stage gas valve provides the regulator, main gas (100% and 50% fire), and manual shutoff functions. The valve is redundant and provides 100% shut off. ➄ Control Step Down - (STD) The control step down transformer is located in the electrical junction box. The transformer is used to step down the supply power (, 208V, 230V, 460V, 575V) to 24V for the gas controls, fan delay relay, field supplied motor starter, etc. To determine the control transformer supplied as well as any accessory/field supplied transformers required, refer to Table 14.1 ➅ Flame Sensor (hidden, STD) Remote flame sensor verifies ignition of all burners, monitors the flame signal and communicates with the integrated circuit board. ➆ Direct Spark Igniter - (hidden, STD) Provides spark for direct ignition of the burners. ➇ Auto High Limit Switch - (hidden, STD) The limit control is mounted in the air stream and will shut off the gas supply in the event of overheating. ➈ gas Pipe Connection Easy access to factory installed gas pipe connection stubbed to outside of unit casing. ➉ Horizontal Air Deflector Blades Factory mounted on the discharge of the unit, the blades can be adjusted to provide horizontal (up and down) delivery control of the heated air. Vertical deflector blades are available as a field installed accessory. 6 6-189.8

GENERAL PERFORMANCE DATA - MODEL PTP Table 8.1 - Propeller Unit Model PTP General Performance Data Model PTP Sizes 150 175 200 250 300 350 400 Btu/Hr Input 150,000 175,000 200,000 250,000 300,000 350,000 400,000 Btu/Hr Ouput 120,000 140,000 160,000 200,000 240,000 280,000 320,000 Entering Airflow (CFM) @ 70 F 2140 2725 2870 3995 4545 5280 5995 Outlet Velocity (FPM) 711 607 643 721 824 748 851 Air Temp. Rise ( F) 53 48 52 47 50 50 51 Max. Mounting Height (Ft.) Heat Throw (Ft.) (@ Max Mtg Ht) 15 14 15 18 19 18 21 51 50 53 62 69 65 74 Motor Type PSC PSC PSC PSC PSC PSC PSC Motor HP 1/6 1/6 1/3 1/3 1/2 1/2 3/4 Motor RPM 1075 1075 1075 1075 1075 1125 1125 Table 8.2 - Propeller Unit Model PTP Operating Electrical Data ➀ Supply Voltage 1 Phase 208V 1 Phase 230V 1 Phase 208V 3 Phase 230V 3 Phase 460V 3 Phase 575V 3 Phase Power Code 01 () Model PTP Sizes 150 175 200 250 300 350 400 Motor Amps 2.8 2.8 5.4 5.4 7.5 7.5 8.8 Total Amps 5.0 5.0 7.6 7.6 8.8 8.8 10.1 kva n/a n/a n/a n/a n/a n/a n/a kva 1.0 1.0 1.0 1.0 1.5 1.5 1.5 208V Total Amps 2.76 2.76 4.20 4.20 4.87 4.87 5.58 kva 0.75 0.75 1.0 1.0 1.5 1.5 0.25 ➁ 230V Total Amps 2.50 2.50 3.80 3.80 4.40 4.40 5.05 kva 1.0 1.0 1.0 1.0 1.5 1.5 1.5 208V Total Amps 2.76 2.76 4.20 4.20 4.87 4.87 5.58 kva 0.75 0.75 1.0 1.0 1.5 1.5 1.5 230V Total Amps 2.50 2.50 3.80 3.80 4.40 4.40 5.05 kva 0.75 0.75 1.0 1.0 1.5 1.5 1.5 460V Total Amps 1.25 1.25 1.90 1.90 2.20 2.20 2.53 kva 0.75 0.75 1.0 1.0 1.5 1.5 1.5 575V Total Amps 1.00 1.00 1.52 1.52 1.76 1.76 2.02 ➀ Amp draw data shown is operating amp draw at incoming power. For units that use a field installed accessory step-down transformer as noted, the amp draw shown is the primary side operating amp draw. For sizing of circuit protection for equipment with National Electric Code.transformers, please refer to the Amp draw data shown is operating amp draw at incoming power. For units that use a field installed accessory step-down transformer as noted, the amp draw shown is the primary side operating amp draw. For sizing of circuit protection for equipment with transformers, please refer to the National Electric Code. ➁ For PTP units that are used on 230V/1ph, all models are equipped with motors except the PTP400 which is equipped with motors that can operate on 230V. Since the transformer does not need to be sized to include the propeller motor, the rating of the Step Down Accessory is sized smaller for the power exhauster and gas control circuit only. 8 6-189.8

GAS CONTROL DATA - ALL MODELS Table 14.1 - Electrical/Control Code Selection Details - All Models Model Supply Voltage Phase 115 1 208 Unit Voltage (Control & Mtr) Accessory Required (Order Separate) none 208V to Control Codes Available Factory Installed ➀ Unit power code must match supply voltage, control voltage must match unit power. ➁ Certain 208V and 230V electrical distribution systems have connections available for supplying service. This may eliminate the need for the additional field installed transformer. Please check with the job site electrician to determine applicability. ➂ For CSA Canada certification, step down transformer may be required to be factory installed. Motor Starter Coil Voltage HD/HDB/ 230 /1ph 230V to PTP 1 or 3 460 460V to 11,12,21,22 to 24V none 575 575V to PDP/BDP 115 1 none PDP 208 208V to ➁ 1 or 3 230 /1ph 230V to ➁ 30,59,63,85,87 to 24V none 460 460V to ➁ 3 575 575V to ➁ 208 208V/1ph 208V to 24V PDP/BDP 1 none 230 230V/1ph 230V to 24V none 31,64,86,88 208 208V/3ph 208V to 24V 208V BDP 3 230 230V/3ph 230V to 24V 230V BDP 460 460V to 230V ➀ ➂ 3 230V/3ph 575 575V to 230V ➀ ➂ 64,88 230V to 24V 230V BDP 460 460V/3ph 460V to 24V 3 none 32,33,93,94 575 575V/3ph 575V to 24V 24V Table 14.2 - Gas Controls All Models ➀ Model HD/HDB/ PTP Model Size 30-400 75-400 Control System Description Single-Stage, Direct Spark Ignition Utilizes a single-stage combination gas control and an ignition control. Gas is automatically lit with the direct spark igniter on call for heat. Two-Stage, Direct Spark Ignition Utilizes a two-stage combination gas control (fires at 50% or 100% of full rated input) and an ignition control. Gas is automatically lit with the direct spark igniter on call for heat. Service Voltage Gas Type Control Code Natural 11 Propane 21 Natural 12 Propane 22 Control Voltage 24V PDP/BDP 150-400 Single-Stage, Intermittent Pilot Ignition Utilizes a single-stage combination gas control and an ignition control. Pilot is automatically lit on call for heat. Two-Stage, Intermittent Pilot Ignition Utilizes a two-stage combination gas control (fires at 50% or 100% of full rated input) and an ignition control. Pilot is automatically lit only on call for heat. ➀ All ignition controls are 100% Shut-Off with Continuous Retry. ➁ Available on BDP models only. 30 208/230V 31 Natural 460V 32 ➁ 575V 33 ➁ 85 208/230V 86 Propane 460V 93 ➁ 575V 94 ➁ 63 Natural 208/230V 64 87 Propane 208/230V 88 24V 14 6-189.8

ACCESSORIES Table 15.1 - Field Installed Accessories Feature Vertical Deflector Blades - Allows directional discharge air control in the left and right directions. Downward Air Deflector Hoods - Available in 30, 60, and 90 configurations these deflector hoods enable the unit to be mounted higher while still providing heat to the building occupants. Refer to page 14 for further details. Model HD HDB PDP BDP PTP Cabinet and Air Mover Vibration Isolation Kit - Minimizes unit vibration transmission to the building structure. Pipe Hanger Adapter Kits - Allows the unit to be suspended by 3/4" pipe from the standard 3/8" holes found in the top of the unit. Discharge Transition for Polytube - Allows for the connection of polytube (not included) to the discharge of the unit. Blower Enclosure with or without Filter Rack - Totally encases the motor and blower assembly. Optional filters provide filtering of the air prior to entering the heater. Discharge Velocity Generating Nozzle - Four varieties of velocity generating nozzles allow for increased application flexibility. These nozzles increase mounting height while also directing the airflow to the desired locations. Refer to page 15 for further details. Belt Guard - Provides protection for building occupants as well as service people from the drive belt and sheaves. Natural Gas to Propane Gas Conversion Kit - Provides all required parts as well as instructions to convert a natural gas unit to propane gas. Single or Two-Stage Room Thermostats - See Table 13.2 for details. Room Thermostat Guard - Clear plastic for room thermostats. Guard is locking type and comes with two keys. Controls Summer/Winter Switch - Allows a choice of unit fan operation. In the summer position, the fan runs continuously for ventilation while allowing the gas controls to fire on a call for heat from the thermostat. In the winter position, the fan runs intermittently on a call for heat from the thermostat. Stepdown s - Used to operate propeller units on 208/230/460/575V/3Ph supply voltage. Also may be required for control circuits for blower units. Refer to Table 12.1 for further selection details. Control Relays - This single pole single throw relay consists of a 24V coil with a maximum contact rating of 18 amps at. Gas Pressure Regulator - Fisher Type S-100, 3/4 inch pressure regulator for 5 to 50 psi inlet pressure capacity, 30 MBH to 400 MBH. Energy Saver Kit - Used to lower total energy costs by reducing stratified air in high mounting height applications. This kit consists of a controller with a SPDT (16A @ 120V) switch and a temperature rage of 30-100 F. Table 15.2 - Field Installed Thermostats Single-Stage Thermostats Two-Stage Thermostats Type Room Thermostat Room - Digital Duct Description White Rodgers 1C20-101: 50-90 F, 1.0A @ 24VAC White Rodgers 1C26-101: 50-90 F, 1.0A @ 24VAC, Heat/Off & Fan On/Auto Switches Honeywell TH5220D1003: 40-90 F, 1.0A @ 24VAC, System Heat/Cool/Auto/Off, Fan On/Auto Johnson Controls A350 Electronic Temp Control with Sensor and S350 Stage Adder (Blower units only) Honeywell T678A1015: 0-100 F, 20' capillary tube (Blower units only) 6-189.8 15

PERFORMANCE DATA - HOODS FOR PROPELLER MODELS Table 16.1 - Downtown Hood General Performance Data for HD/PDP/PTP (feet) Model HD Sizes Model PDP Sizes Model PTP Sizes 60 75 100 125 150 175 200 250 300 350 400 150 175 200 250 300 350 400 Max Mtg Height (ft.) 9 11 11 12 18 18 18 22 24 24 24 16 16 15 20 22 21 23 X 4 5 5 6 6 9 6 8 8 8 8 6 5.6 7 7.2 8.2 7.4 11 30 Hood Y 11 14 14 16 20 26 18 24 26 24 24 20 17 20 22 25 23 31 Z 16 21 20 23 29 37 26 35 38 36 35 29 26 29 32 37 34 44 X 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 60 Hood Y 8 12 12 14 13 23 12 16 19 16 16 17 14 17 18 21 18 26 Z 12 17 17 19 19 32 17 23 28 24 23 24 21 24 26 30 26 37 90 Hood S 10 14 13 15 23 25 22 29 32 20 29 17 16 16 20 22 21 24 Figure 16.1-30, 60, and 90 Downward Deflector Hoods Figure 16.2-30 and 60 Throw/Floor Coverage MOUNTING HEIGHT 30 DOWNTURN 60 DOWNTURN 60 30 30 HOOD 60 HOOD 90 HOOD X 60 DOWNTURN Y X Z 30 DOWNTURN Note: X = Feet from Heater to Start of Floor Coverage Y = Feet to End of Floor Coverage Z = Feet to End of Throw Y Z Figure 16.3-90 Hood Throw/Floor Coverage H S S 16 6-189.8

DIMENSIONAL DATA - MODEL PTP Propeller Units - Model PTP Figure 23.1 - Dimensional Drawings ADJUSTABLE LOUVERS R S G 4 MOUNTING HOLES T U A POWER VENTER VENT PIPE CONNECTION ACCESS PANEL E OPENING B F GAS CONNECTION J T-STAT CONNECTION C M (APPROX) D OPENING H I ELECTRICAL CONNECTION MOTOR CORD STRAIN RELIEF Q (MIN DIST TO WALL) Table 23.1 - Dimensions (inches) - PTP Models PTP150 PTP175 PTP200 PTP250 PTP300 PTP350 PTP400 A 35.53 42.53 42.53 42.53 42.53 42.53 42.53 B 23.06 25.81 25.81 31.31 31.31 39.56 39.56 C 22.05 22.05 22.05 22.05 22.05 22.05 22.05 D 22.52 29.52 29.52 29.52 29.52 29.52 29.52 E 21.18 23.93 23.93 29.43 29.43 37.68 37.68 F 15.33 16.70 16.70 19.45 19.45 23.58 23.58 G (Mounting Hole) ➁ 3/8-16 3/8-16 3/8-16 3/8-16 3/8-16 3/8-16 3/8-16 H 8.37 8.37 8.37 8.37 8.37 8.37 8.37 I 4.50 4.50 4.50 4.50 4.50 4.50 4.50 M 31.79 32.83 34.43 33.83 33.83 34.83 34.83 Q ➂ 43.79 44.83 46.43 45.83 45.83 46.83 46.83 R 3.56 3.56 3.56 3.56 3.56 3.56 3.56 S 14.90 14.90 14.90 14.90 14.90 14.90 14.90 T 10.00 10.00 10.00 10.00 10.00 10.00 10.00 U 13.54 20.53 20.53 20.53 20.53 20.53 20.53 Gas Connection 1/2 1/2 1/2 3/4 3/4 3/4 3/4 Vent Connector Size 4" 4" 4" 6" 6" 6" 6" Fan Diameter 20.00 22.00 22.00 22.00 22.00 24.00 24.00 Approx. Shipping Weight (lbs.) 165 210 220 265 270 310 320 Do not use propeller units with duct work. Listed is the hole diameter and threads per inch to accept threaded rod. Dimension equals overall plus 12". 6-189.8 23

model nomenclature Figure 26.1 - Model Number Designations PDP 200 A E 01 30 S B A N Unit Configuration HD - Tubular Power Vented Propeller Unit HDB - Tubular Power Vented Blower Unit PDP - Propeller Unit Power Vent BDP - Blower Unit Power Vent PTP - Tubular Power Vented Propeller Unit MBH Input (refer to pages 7 & 9) 100-100,000 Btu/hr input 200-200,000 Btu/hr input 250-250,000 Btu/hr input etc. Heat Exchanger Type A - Aluminized S - Stainless Steel Ignition Type E - Unit equipped with intermittent pilot ignition S - Direct Spark (HD/HDB/PTP only) Power Code (refer to pages 10 & 11) 01 - /60Hz/1ph 02-230V/60Hz/1ph etc. Dev Digit Future A - All Fan Guard Digit S - Standard F - Fingerproof N - None (all blower models) Factory Installed Option Digit N - None Control Code Type (refer to page 14) 11 - Natural gas, single stage (HD/HDB) 21 - Propane, single stage (HD/HDB) 30-115v/25v intermittent pilot ignition, 100% Shut-Off, with continuous retry, natural gas 31-230v/25v intermittent pilot ignition, 100% Shut-Off, with continuous retry, natural gas etc. 26 6-189.8